Loading...
HomeMy WebLinkAbout2875 LOKER AVE E; ; AS160175; Permit12/8/2020 AS160175 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160175 2875 LOKER AV Job Address: Status: ISSUED EAST Permit Type: SPRINK Applied 6/1/2016 Parcel No: 2090831000 Approved: 6/8/2016 Lot #: 0 Reference No.: Issued: 6/8/2016 PC #: Inspector: Project Title: ZEST ANCHORS II T.I. Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON ST P0 WAY CA 92064 858-513-4949 Owner: TECHBILT CONSTRUCTION CORP P 0 BOX 80036 SAN DIEGO CA L Fees ($) Add'l Fees ($) Total ($) Balance 325.5 0 325.5 0 1/1 _ - - Western Fire Protection Inc. Material Submittal Zest Anchor Phase II 2875 Loker Avenue San Diego, CA 92010 Job#TIC- 1441 AS160175 2875 LOKER AV EAST 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 GL& Eamn UUM FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TOMA TI C SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the ,---- thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design QUICK RESPONSE requirements. Quick Response Sprinklers should be used advisedly UPRIGHT CONVENTIONAL and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains - a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL See reverse side for Approvals and Specifications. SIDEWALL *Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) *Factory tested hydrostatically to 500 psi (34 Bars) *Maximum low temperature glass bulb rating is -67°F (-55°C) *Frame - bronze • Deflector - brass • Screw - brass *Bulb seat - copper • Spring - nickel alloy • Seal - teflon QUICK RESPONSE Bulb - glass with alcohol based solution, 3mm size HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARY 1350F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/930C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 9 FAX 989-846-9231 MAY 2011 A-20 BULLETIN GL5615, REV. #7 989-846-4583 1-800-248-0278 GLAS FIRE SPRINKLER CORPORATION 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4' (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Bright Chrome Satin Chrome 2 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 2,3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2.3 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F. M. LPC CE NYC - DOB MEl MODEL FACTOR 57°C 68°C 79°C 93°C 141°C 101-92-E GL2815 2.8 X X X X X X - - - X GL4215 4.2 X X X X X X - X UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8* X X X X X X -- - - X GL8118 8.1 X X X X X X X X X X GL2801 2.8 X X X X X X -- - - X GL4201 4.2 X X X X X X -- - X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8° X X X X X X X - X GL8106 8.1 X X X -X X X X X X X VERTICAL GL5632 5.6 X X X X X X X - - - SIDEWALLt GL8133 8.1 X X X X X X - - - GL2826 2.8 X X X X X X - - X HORIZONTAL GL4226 4.2 X X X X X X - - - X SIDEWALL § GL5626 5.6 X X X X X X X - - X GL8127 8.1 X X X X X X - - CONVENTIONAL GL5624 5.6 X X X X X - - X X (OLD STYLE) GL8125 8.1 X X X X X - - X X - *1/2 NPT t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6'. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2'); P/N 312366 (L.O.) MAY 2011 PRINTED U.S.A. BULLETIN GL5615, REV. #7 F P P I Description Recessed Canopy Coverage Extensions provider increased coverage of the recessed canopy flange against the ceiling or wall material where it is installed. The primary purpose is to allow for increased distance between the finished surface of the building interior and the recessed sprinkler assembly. AHJs within certain earthquake zones require a minimum of 1" space between the sprinkler or sprinkler drop and the material it penetrates. Can also be used to provide coverage for oversized holes cut in finish material from previous sprinkler placements. Fits most existing recess sprinkler canopies and is compatible with all FPPI Recessed Canopys. Installation No tools are required for installation of the Recessed Canopy Coverage Extension. Simply slide the recessed escutcheon skirt through the ID of the coverage extension then install or re-install the recessed escutcheon skirt on to the retainer. Press the recessed skirt firmly into place against the interior surface the sprinkler penetrates without causing the interior surface to be moved or lifted by the recessed skirt/coverage extension. Follow sprinkler manufacturers instructions regarding the installation of sprinklers in recessed applications. May be used either horizontally or vertically. Specifications Material: .020" Cold Rolled Steel Standard finishes: Chrome White Coverage: 5" x 115/16" ID Item Numbers: 01-491 5" Coverage Chrome 01-493 5" Coverage White GL6 EAman UUMN FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION ,,,,THE INCH" QUICK RESPONSE A UTOMA TIC SPRINKLERS MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2%" diameter ceiling plate colorfinished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burstallowing the deflectorto drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA 'See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate 'Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) 'Maximum low temperature glass bulb rating is -67°F (-55°C) 'Frame - bronze ' Deflector - brass ' Screw - brass 3 5/16" diameter plate 'Bulb seat - brass • Spring - nickel alloy 'Seal - teflon 2 3/4" diameter plate 'Bulb - glass with alcohol based solution, 3mm size QUICK RESPONSE 'Drop Pin - stainless steel WHITE ADJUSTABLE 'Cover Plate - brass CONCEALED PENDENT 'Upper Escutcheon Assembly - plated steel NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. 'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE BULB N.F.P.A. MAXIMUM CEILING CLASSIFICATION SPRINKLER TEMPERATURES COLOR TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 790C/930C YELLOW/GREEN 150°F 66°C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989) 846-4583 • FAX 989-846-9231 MAY 2012 A-38 BULLETIN GL5606 REV#6 QUICK RESPONSE A UTOMA TIC SPRINKLERS MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES Bright Chrome White Painted 5.6 (80 metric) 1/2'NPT 21/2(6.4cm) Bright Brass' Satin Chrome' Other Painted Finishes' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. APPROVALS **1350F (57°C) 155°F (68°C) **1550F (68°C) 175°F (79°C) 200°F (93°C) NYC-DOB STYLE SIN K with plate with plate with plate with plate with plate cULus *FM MEA MODEL FACTOR 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 101-92-E Adjustable Concealed GL5606 5.6 X X X X X X X X Pendent *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS CROSS SECTIONS supP CEIU OPTIONAL COVER WHlTE135°F WHITEI55°F CHROMEI35°F CHROMEI55°F PLATE SIZE PART # PART # PART # PART # 2 3/4" 332726 332731 332724 332729 35/16" 332706 332711 332704 332709 ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Adjustable Concealed Wrenches - P/N 332765 GL;BE FIRE SPRINKLER CORPORATION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com MAY 2012 PRINTED U.S.A. BULLETIN GL5606 REV#6 GIkBE FIRE SPRINKLER CORPORATION COVER PLATE WITH GASKET SEAL FOR CLEAN ROOM APPLICATIONS COVER PLATES The Seal is intended for areas where it is desirable to stop air travel through the cover plate from the area above the ceiling. For "The Inch" Standard Response GI-5653, For Full Description See Pages: A-69-CR Finish/Part No. 135 0 Chrome: 332739 *White: 332737 Finish/Part No. 1550 ADJUSTABLE "CLEAN ROOM" Chrome: 332740 COVER PLATE White: 332741 cULus Approved: GL5653 -135°F (57°C) with plate 135°F (57°C); 155°F (68°C) with plate 135°F (570C); 155°F (68°C) with plate (680C); 175°F (79°C) with plate 155°F (680C); 200°F (93°C) with plate 155°F (68°C) MAY 2009 BULLETIN: CLEAN ROOM