HomeMy WebLinkAbout2925 LUISENO WAY; ; FPR2016-0036; PermitPERMIT REPORT Lcity of Carlsbad Print Date: 12/08/2020 Job Address: 2925 LUISENO WAY, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #.: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: QUARRY CREEK APARTMENTS - FIRE ALARM (NEW) - BLDG 1 BLDG 1, 2, 3, 4 AND SON PLANS BLDG 1- 2925 LUISENO WAY BLDG 2 - 2935 LUISENO WAY BLDG 3 - 2945 LUISENO WAY BLDG 4- 2955 LUISENO WAY BLDG 5 - 2965 LUISENO WAY Permit No: FPR2016-0036 Status: Closed - Finaled Multifamily Fire Alarm Applied: 12/19/2016 Issued: 01/19/2017 Finaled Close Out: 12/08/2020 Inspector: Final Inspection: FPContractor: HCI SYSTEMS INC 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 (909) 628-7773 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov -' - oo 3? HCI Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: QUARRY CREEK APARTMENTS 2925, 2935, 2945, 2955, 2965 LUISENO WAY., CARLSBAD, CA. 92010 Ontario • San Diego • Irvine • Northern California Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (877) 331-2084 FAX: (909) 628-7774 24-Hour Service: (909) 628-8886 Website: www.hcisystems.net Manufacturer QUARRY CREEK APARTMENTS 2925, 2935, 2945, 2955, 2965 LUISENO WAY., CARLSBAD, CA. 92010 Device Model # Description C.S.F.M. # BOSCH FPD-7024 Fire Alarm Control Panel 7165:1615:0227 Include With: BOSCH B440 Conettix Plug-in Cellular Communicator 7165-1615:0227 BOSCH B450 Conettix Plug-in Communicator Interface 7165-1615:0227 TRI-ED S1A1079 7.2 Amp Hour Sealed Lead Acid Battery FIRELITE FCPS-24FS6 6 Amp Booster Power Supply 7315-0075:0206 BOSCH D263 Photoelectric Smoke Detector (Conventional) 7272-1615:0134 SYSTEM SENSOR SYS-HWLF Low Frequency Wall-Mounted Horn 7135-1653:0223 SYSTEM SENSOR SYS.PC2W Horn/Strobe Ceiling White 7125-1653:0186 SYSTEM SENSOR SYS.S224MCW 15cd Wall-Mounted Strobe, White 7125-0067:0252 BOSCH FMM-100SATK Single Action Pull Station (Conventional) 7150-1615:0224 0 www.boschsecurity.com 0BOSCH Invented for life S Four initiating zones (expandable to eight); up to 20 two-wire smoke detectors per zone Programmable through keypads or remote programming software (RPS) through a Conettix interface module Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module TheFPD-1024, Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD-7024 FACPs support four on-board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two-wire and four-wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two-wire detectors, or any number of four-wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the FPD-7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD-7024 turns the conventional FACP into an addressable FACP. The 07039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for Wheelock, Gentex, or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light-emitting diodes (LEDs) and liquid-crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off-normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR-7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. 2 I FPD-7024 Fire Alarm Control Panels History Buffer Detectors For two-wire detector compatibility, refer to The system stores events in a 99-event history buffer. FPD-7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) E1 Notice Keypads and D7030X Eight-point LED annunciator (eight red) The number of events that can be stored in the Annunciators history buffer increases to 499 with the addition D7030X-S2 Eight-point LED annunciator of a D7039 Multiplex Expansion Module. (two yellow, six red) - D7030X-S8 Eight-point LED annunciator Central Station Reporting (eight yellow) The FPD-7024 FACPs send reports to two telephone - - numbers (or, if a Conettix interface module is D7032 Eight-point LED annunciator expander installed, IP addresses) to an appropriate Conettix (eight red) receiver at the central station with full single, double, FMR-7033 LCD fire system keypad and backup reporting. The panel supports - - - - - - - - - communication in BFSK, SIA, Contact ID, Modem Ilia 2, FMR-7036 LCD annunciator and 4/2 or 3/1 Tone Bursts. Modules D132B Smoke detector reversing relay module Dirty Smoke Detector Monitoring D184A Local energy kit All on-board zones and FPC-7034 zones are - continuously monitored for smoke detectors signaling D185 Reversing polarity module a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke D275 EOL power supervision module - - chamber is dirty, the detector sends a CleanMe signal FPC-7O34 Four-point expander on the two-wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that D7039 Multiplex expansion module - - there is a dirty detector on the loop or the address. Option Bus D7035 Octal relay module The Chamber Check feature signals a dirty smoke Devices chamber using the LED on the detector head. D7035B Octal relay module in box - - Accessories DX401OV2 USB/seriai interface module The FPD-7024 enclosure has space for additional DX4020 Network interface module - accessory modules and two D1218 (18 Ah) batteries --- - ---•-•-.--- - or two D126 (7 Ah) batteries. B42O Ethernet communicator - - - - Certif ications _and _approvals ____________________________ B426 Ethernet communication module B440 Conettix plug-in cellular Region Certification - - B441 Conettix plug-in cellular USA UL UOJZ: Control Units, System (ANSI/UL - 864) B442 Conettix plug-in GPRS cellular FM FPD-7024 B443 Conettix plug-in HSPA+ cellular CSFM see our website B450 Conettix plug-in communicator interface FCC ESVAL04B7024 - ITS-DX4020-G GPRS/GSM communicator FDNY- #6173 CoA NAC Devices Refer to FPD-7024 Device Compatibility List Technogram(P/N:F01U010791) Compatible Products The following products are compatible (refer to the product datasheet for country-specific certifications/ approvals) with the FPD-7024 FACP: Category Product ID and Description Batteries and D126 12 V. 7 Ah battery Power Supplies D121812V, 18 Ah battery FPP-RNAC-8A-4C Remote NAC power supply The following additional products are compatible with the FPD-7024 Addressable FACPs: Category Product ID and Description Detector Heads D7050 Addressable Photoelectric Smoke Detector and Bases Head D7050TH Addressable Photoelectric Smoke and Heat Detector Head D7050-136 Detector Base Modules D7042 Multiplex eight-input remote module 3 I FPD-7024 Fire Alarm Control Panels . D7042B Multiplex eight-input remote module in box D7044 Multiplex single-input module D7044M Mini multiplex single-input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual-input module D7053 Multiplex input-output module Pull Stations FMM-7045 Single-action manual station FMM-7045-D Double-action manual station Parts ryrrrr FPD-7024 Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) keys (P1 N: F01U083084) 1 Transformer (P/N: F01U033706) 6 2.21 ko)end-of-Iine (EOL) resistors (P/N: F01U034504) 1 Hardware pack 1 Literature pack Notice For the FPD-7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. FPD-7024-LC Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Hardware pack 1 Literature pack FPD7024-LT (Latin America only) Quant Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) keys (PI N: F01U083084) 6 2.21 kC) end-of-line (EOL) resistors (P/N: f01U034504) 1 Hardware pack 1 Literature pack FPC-7024•FK1 Quant. Component 1 FPD-7024FACP 1 1`220-136E 6-in. (15.24-cm) diameter, 4-wire base with EOL relay 1 F220-P photoelectric spot smoke detector 1 SS-P2R Two-wire Horn Strobe 1 FMM-100SATK manual station (red) 2 D162@24 2-ft (60.96-cm) dual modular phone cord 2 D166@24 RJ31X phone jack Electrical Current (alarm)*:' 380 mA' (current (stand by)° 200 mA Power (primary): 120 VAC 1.2 A maximum, 60 Hz or 240 VAC, 0.75 A maximum, 50 Hz * For product-specific current values, see the product's Installation Instructions. Environmental Environment: Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F (0°C) to +120T (+49°C) Mechanical Properties Color: Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm 38.1 cm 10.9 cm) Material: Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (lDC) Current: 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal Outputs NAC: 24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40 4 I FPD-7024 Fire Alarm Control Panels Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. ri17 iy rn FPD-7024 FACP - Four detector zones (expandable to eight); up to'29 two wire smoke detectors per zone Order number 064624 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024-LC FPD-7024•LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. Order number FPD-7024-LT Accessories FPC-7024-FK1 Basic Fire Panel Kit Four-zone FACP with one four-wire photoelectric smoke detector and base with EOL relay, one two-wire horn/strobe, one manual station, and two RJ31X phone jacks with dual modular phone cords. Order number FPC-7024•FK1 D102 Replacement Key Replacement key (#1358) for the D101 lock. Order number D102 Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O. Boo 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98 Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone: -1 800 289 0096 Phone: v 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil Fax: +1585 223 9180 security.sales@us.bosch.com Fax: +3140 2577 330 emea.securitysystems@bosch.com Phone: *65 6571 2808 Fax: +65 6571 2699 200335 China Phone *86 21 22181111 Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 www.boschsecurityus www.boschsecurity.com apr.securitysystems@bosch.com Fax: *86 21 22182398 latam.boschsecurity@bosch.com www.boschsecurity.asia www.boschsecarity.cum.co www.boschsecurity.com © Bosch Security Systems 2014 Data subject to change without notice 2692228235 1 an, V17, 18. Dec 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-1615:0227 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski©us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad 07035, D7035B; Expanded Relay Module 0185; Reverse Polarity Module D7039; MUX Expander D7042, 0704213, 07044, 07044M, D7052, D7053; Mulitplez Expander Module D7048, D7048B; Octal Driver Module B440, 13441, *B443; Cellular Modules B450; Interface Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Revsion 09-20-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Callout Description 1 - B440 Conettix Plug-in Cellular Communicator 2 - Compatible control panel 3 - Antenna cable 4 - Magnetic base antenna 5 - Base station on wireless carrier's network 6 - P network cloud Callout Description 7 - Remote PC's network connection 8 - Remote PC running RPS 9 - Personal SMS notification 10— Ethernet connection 11—Central montoring station www.boschsecurity.com 0BOSCH Invented for life Secure Conettix IP communication from compatible Bosch panels to Bosch receivers Remote programming and monitoring of compatible Bosch panels . Personal SMS message and e-mail notification options o. Configured directly from Bosch Remote Programming Software (RPS) eliminating the need for separate configuration Simple LED status information and advanced keypad diagnostics available The44enables 3G EVDO and CDMAsecure two way IP communication over the Verizon cellular networks. Typical applications are: Alarm reporting to a central station Remote panel programming through Remote Programming Software Remote monitoring and control through a mobile application Personal notification using SMS The B440 is built for a wide variety of secure commercial and industrial applications. Flexible end- to-end path supervision, 128-bit to 256-bit AES encryption and anti-substitution features make B440 desirable for high security and fire monitoring applications. Developed for the military, CDMA technology offers long service life with resistance to hacking and jamming. The B440s dual technology radio will use high speed 3G EVDO when available or switch to CDMA if required. Note: Cellular capability requires an appropriate data plan from Bosch. 2 I B440 Conettix Plug-in Cellular Communicator Conettix IP communication via Cellular Mounting Considerations In addition to the security provided by the network The B440 plugs into any B Series control panel, operator, the B440 uses our Conettix lP protocol that available in a variety of enclosures. supports: Wiring Considerations Flexible polling intervals The B440 connects to the B Series control panel Resistance to Denial of Service attacks without tools or physical wiring for power. It has a 128-bit to 256-bit AES encryption with Cypher Block screw on SMA antenna connection. Chaining Cellular Service Considerations Anti-replay/anti-substitution keys The B440 is shipped pre-activated for Bosch Cellular Easy Installation, troubleshooting, and maintenance service on the Verizon cellular network. A valid service No networking expertise required at field site (no contract is required prior to ordering. firewall or router settings) No PC or special tools required for installation and Parts included troubleshooting Manage service plans and settings through RPS Quantity Component Diagnostic LEDs for on-site troubleshooting - 1 B440 Conettix Plug-in Cellular LED Function -- Communicator Blue (heartbeat) System status Indicator 1 - - - - - - - Antenna Red Unacceptable signal strength 1 Literature pack Yellow Marginal signal strength __________________________________ Technical ___specifications 1 Green Good signal strength -_ Electrical 2 Green Very good signal strength - - - - çcurren Standby: 35 niA Remote programming of Bosch control panels (operating) Alarm: 150 mA - -- The B440 supports secure RIPS programming of compatible Bosch control panels. Voltage (operating) 12VDC nominal Personal notification and control Radio Verizon CDMA dual band radio The B440 supports the Bosch Remote Security Control - ______. - - 850 MHz and 1900 MHz mobile application and can be configured for SMS Environmental personal notification reports to mobile phones or e- - mail addresses. Environment Environmental Class Ill - Indoor - - ____________________________ Certifications _and _approvals Relative humidity 5 - 93% at +32°C (+90°F) non-condensing -- Operating -10°Cto +55°C(+14°Fto +131°F) Agency temperature FCC FCC, Part 15 Class B Radiated/Conducted Emissions Mechanical - - Verizon Open Development Certified Board dimensions - 2 in x 3.68 in x 0.60 in (50 mm x 93.5 mm x 15.25 mm) UL UL 365- Police Station Connected Burglar Alarm Units - - - - and Systems Antenna (included) • Magnetic base omni-directional 8.2 ft (2.5 m) cable with SMA connector UL 636- Holdup Alarm Units and Systems - - - -- - Compatibilities UL 985- Household Fire Warning System Units — - - - - - - - - - - UL 1023-Household Burglar-Alarm System Units - - -- - - Control panels B5512 control panel B4512 control panel UL 1076 - Proprietary Burglar Alarm Units and Systems B3512 control panel - V - - - - - UL 1610-Central-Station Burglar-Alarm Units Cellular EVD0 rev A CDMA2000 V 1xR1T Region Certification USA CSFM 7167-1615:0247 7167 CONTROL UNIT (HOUSEHOLD) 3 I B440 Conettix Plug-in Cellular Communicator B440 Conettix Plug-in Cellular Communicator Dual technology 3G EVDO/CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B440 Represented by: American: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perintun Parkway P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Rood Via Anhanguera, Km 98 Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone: -1800 289 0096 Phone: * 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Soy Paulo, Broad Fan: *1585 223 9180 security.sales@us.bosch.com Fax: +3140 2577 330 emea.securitysystems@bosch.com Phone: +65 6571 2808 Fax: +65 6571 2699 200335 China Phone +86 21 22181111 Phone: *55 19 2103 2860 Fax: +55 19 2103 2862 • www.boschsecurity.us www.boschsecurity.com apr.securitysystems@bosch.com Fax: *86 21 22182398 latam.boschsecarity@bosch.com www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecority.com 0 Bosch Security Systems 2013 ) Data subject to change without notice 7682076555 1 en, V5, 25. Nov 2013 S www.boschsecurity.com 0BOSCH Invented for life o. Enables full two-way IP communication using Plug-in Cellular Communicators o. Plug and Play installation makes future radio technology changes easy o. Compatible with new and most deployed Bosch control panels 0. Supports remote installation of cellular modules for improved signal S The45OConettix Plug-in Communicator Interface is a four-wire powered 5D12, SDI, or option bus device that provides two-way communication with compatible control panels over commercial cellular networks using a plug-in communicator (available separately). Use B450 in combination with a plug-in communicator for primary or backup alarm communication, remote panel programming and other remote applications. The B450 supports Conettix IP protocol with full authentication, 256 bit AES encryption and resistance to Denial of Service attacks. It is a reliable way to add cellular network communications to existing or new commercial security and fire installations. B450 system overview Callout- Description Callout- Description 1 - Compatible Bosch control 6- Cellular carrier network panel 2 - Panel data bus (S012, SDI, or 7-Internet/LAN/WAN Option) 3- B450 Plug-in Communicator 8- Remote Programming Interface Workstation 2 1 B450 Conettix Plug-in Communicator Interface 4- USB connection for B450 9-Bosch Conettix IP receiver CAN/ULC S304 configuration (D6600, D6100i, or D6100lPv6) - - ULCS545 5-B44x Plug-in Cellular - - - Communicator (available ULC-ORD C1023 separately) - ULC-ORD C 1076 - - Functions ICES-003 - Digital Apparatus Conettix IP communication Rogers - Certified The B450 uses Conettix IP protocol which supports: Full event code reporting and administration North PTCRB - Certified America Flexible supervision intervals Resistance to Denial of Service attacks Europe CE - EN50130-4, EN61000-6-3, EN60950 128, 192 or 256-bit AES encryption Anti-replay and anti-substitution Installation/configuration notes Switch addressing Mounting considerations Use the address switch to easily assign a bus address Find a location with acceptable signal strength on your or setup for USB or SMS configuration where required. wireless network. Mount the B450 Conettix Plug-in Easy configuration Communicator Interface into the interior of a For most installations, the default B450 settings allow compatible enclosure via the 3-hole mounting pattern installation with no device programming required. An using the supplied mounting screws. address switch allows easy bus address selection. Wiring considerations For customized network settings, the B450 supports a The B450 connects to a control panel using a data bus USB configuration menu, or configuration via SMS. B connection via the module's terminal strip, or the Series and GV4 Series control panels support limited module's interconnect wiring connectors. keypad and RPS programming of B450 settings. For data bus powered installations outside the LEDs compatible control panel enclosure, follow the Three LEDs provide status and troubleshooting maximum wiring distances in the technical information about the module and its connection, specifications. For further installations power from a - compatible auxiliary power supply. LED Description - - Heartbeat Indicates the system status of the B450 and its rr Parts included connection to the panel. - - - - Quantity Component RX Indicates when an inbound packet is received on the - - 1 B450 Conettix Plug-in bus. Communicator Interface TX Indicates when an outbound packet is transmitted on - - - - 1 Hardware pack the bus. - - 1 Interconnect cable wiring Certifications-I1 and approvals 1 Quick Start Guide (hardcopy) Region 1 Literature (mini-CD) US NIST FIPS 197 FCC Part 15 Class B Technicalispecifications - ----------- Electrical UL 365 -. - - UL 636 Current, Standby: B450 with B440/1344 1/13442/13443 = (operating) *60 mA UL 864 Alarm: B450 with B440/13441/13442/13443 - 180 m UL985 - -. Voltage (operating) (B450 bus operation): 12 VDC nominal UL 1023 - - - - - Environmental UL 1076 - - - ------ Relative humidity Up to 93% at +32°C (+90°F) non-condensing UL 1610 -- S -- •-- Operating 0°Cto+50°C(+32°Fto+122°F) Canada CAN/ULC S303 temperature Installed Bus Configure N V GV4/B Series B450 from v203+, AMAX control panel vX.X, Solution (RPS, A-link) vX.X Personal N V Requires Notification compatible via SMS or control panel Email and cellular plan Remote N Requires Security Bosch Cellular Control App service or other cellular network access B450 Conettix Plug-in Communicator Interface Supports two-way IP communication over using a plug- in Cellular Communicator for compatible 5D12, SDI or option bus control panels. Order number B450 Accessories B440 Conettix Plug-in Cellular Communicator Dual technology 3G EVDO/CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B440 B441 Conettix Plug-in Cellular Communicator Multi-function CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B441 China: America Latina: Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 201 Building, No. 333 Foqoan Road Via Anhanguera, Km 98 North IBP CEP 13065900 Chongning District, Shanghai Campinas, Sao Paulo, Brazil 200335 China Phone: +55 19 2103 2860 Phone *86 21 22181111 Fax: +55 19 2103 2862 Fax: +86 21 22182398 latam.boschsecority@bosch.com www.boschsecurity.com.cn www.boschsecurity.com 3 I B450 Conettix Plug-in Communicator Interface S Mechanical Board dimensions 79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in) Wiring Data bus wire 12 AWG to 22 AWG gauge USB cable USB cable (Type A to A male-to-male) — not supplied Data bus wire Maximum Distance length - wiresize: 22 AWG (0.65 mm) --> 12 m (40 ft) 18 AWG (L0 mm) -->30m(100ft) 16 AWG (1.3 mm) -->48m(158ft) 12 AWG (2.0 mm) --> 122 m(400ft) Using a separate power supply, such as the B520 Auxiliary Power Supply Module, connected to the B450 within the specification listed above, the wire distance can be extended up to 300 m (1000 ft) Compatibilities Control panels B5512/B4512/B3512 (B5512E/B4512E/ B3512E with firmware v2.03 and higher) D9412GV4/D7412GV4/D7212GV4 (vL000xx+) D9412GV3/D7412GV3/D7212GV3 D9412GV2/07412GV2/7212GV2 (v7.06+) FPD-7024 AMAX 2000/2100/3000/4000 CMS 6/8/50 Solution 2000/3000 Cellular B440 Conettix Plug-in Communicator, Cellular (3G) communicators B441 Conettix Plug-in CDMA Cellular Communicator B442 Conettix Plug-in GPRS Cellular Communicator B443 Conettix Plug-in HSPA+ Cellular Communicator Enclosures B10 Bil D8103 D203 Applications Tera Term (for USB B450 configuration) Hyper Terminal (for USB B450 configuration) RIPS version 5.16 or higher Installed Bus Function Option/SDI SDI2 Details P Event V V TCP protocols Reporting only supported on Represented by: S012 Anericas- Eyope, Middle East, AMc AMa-Pacific: B&1e1te.lY Systems, Inc. Bisch Security Systems B'J. Rfl qI.tJes (SEA) Pte Ltd, Security 1fl9)Ffi Rp:tY P.O. Box 80002 Spçc ('elliilr FalrpqR )qnj Vork, 14450, USA 5617 BA Eindhoven, The Netherlands llBiThpn Streer21 poj-.linxip 289 0096 Phone: + 3140 2577 284 SdM6øZ943 Fax: +1585 223 9180 Fax: -3140 2577 330 P45,808 security.sales@us.bosch.com www.boschsecurity.us emea.securitysystems@bosch.com www.boschsecurity.com F: afetWerystems@bosch.com wo99 hsecuritY.asia © Bosch Security Systems 2014 Data subject to change without notice - 110361862511 an, VS. 03. Mar 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-1615:0227 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, 0703513; Expanded Relay Module D185; Reverse Polarity Module D7039; MUX Expander D7042, 07042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module 07048, D704813; Octal Driver Module B440, B441, *13443; Cellular Modules B450; Interface Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsion 09-20-16 dc 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Mv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCPS-24FS6 is 24 Volt, 6 Amp Power Supply General The Fire•Lite FCPS.24FS6(C/E) is a compact, cost-effec- tive, 6-amp remote 06wer&ippIies with battery charger. The FCPS-24FS6(C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24FS6(C/E) also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FCPS- 24F56(C/E) is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS6 used in this document refers to the standard FCPS-24FS6, FCPS- 24FS6G, FCPS-24FS6E Features • UL-Listed Notification Appliance Circuit (NAG) synchroniza- tion using System Sensor, Wheelock, or Gentex 'Com- mander2" appliances. . Operates as a "sync-follower" or as a "sync-generator' S (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). • Two Glass B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) • 6-amp full load output, with 3 amps maximum/circuit, in NAG expander mode (UL 864). • 4-amp continuous output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. • Optional power-supervision relay (EOLR-1). • In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. • Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AG trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). S . Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5"W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). DF-52301 :A2 • D-025 8 Flre•LITeALarmS by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS6: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24FS6/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 -16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24F: 4.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FGPS-24F: 6.0 A maximum. DF-52301 :A2 • 5/17/13 - Page 1 of 4 Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24F56 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS6 is configured (via DIP switch settings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24FS6 is configured (via DIP switch settings) as a "sync generator:' the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24F56 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4— DF-52301:A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424, S1287 ULC Listed: S2424 CSFM Approved: 7315-0076:176 MEA: 387-94E Ordering Information (F -24s6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ',FCPS-24FS6 is ULC listed FCPS-24FS6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required). PS-1270: Battery, 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. [1 NOTE: All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output #4 Output #3 Output #2 Output #1 Output AC Power INPUT/OUTPUT FUNCTIONS are programmable by SWI DIP switch settings 24VDC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) Sync Input FCPS Battery Charger Simplified Block Diagram DF-52301 :A2 • 5/17/13 - Page 3 of 4 III I I • -fi- I ON Z--) 0 0 000j ID 0 000 -' U U CL .?l? V 00 90 0 S a•a E _ flZO) 0000 zzo W E LL 9L 2 ID N5 C/) N 23 e [0o III_v- _________ 0 00 +1 I' + 53l Fr 3o + Zz +I 00 U) ZZj3 Ri1 1 zi; a 0 C N a p. 0 CO I_ U) U I.. 0 CL C. CM E o a. E - > -S E - C C -0.0. .E U e Q x C C - C C c C rs 0 0 0 0 >. >. LLj -0 < < 0 0 0 0 0 C) (15 (1) + + I + I + I + --H+I I 1501 L> ' / 0 )0 0 eo .. OIL $ S. ~ I Board Layout System Sensor® and FireLite® Alarms are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - - - - - I This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 01727 a a J= We cannot cover all specific applications or anticipate all requirements. ENCINEWS & MINIFACIIEIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— OF-52301:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM CAL FIRE LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneyweII.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division www.boschsecurity.com BOSCH Invented for life 12 V or 24 V input Designed for commercial or residential use . Two-wire application . Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm Removable terminal block to simplify wiring connections 'It The D263 family includes the following detector models: Model Description 02631H Two-wire with 135°F (57°C) heat sensor D2631HS Two-wire with 135°F (57°C) heat sensor and sounder * Sounders produce 85 dB at 10 ft (3 m). Each of these detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. These detector models use an infrared (IR) LED light is source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and to reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. Use a D132B Reversing Relay Module to activate the sounder (85 dB at 10 ft [3 m]). When using a D13213, the LED does not latch on alarm. Chamber Calibration Tests Check the sensitivity and calibration of any of these detectors using a visual check, a magnet test, or a voltage measurement test. Visual check: When the detector's calibration is within the factory- listed range, the red alarm LED flashes once every 3.5 sec. If the detector's calibration is out of range for more than 24 h, the red alarm LED flashes once a second. Magnet test: 2 I D263 Photoelectric Smoke and Smoke and Heat Detectors Hold a magnet horizontally against the detector for about 10 sec and observe the LED. If the detector is within the factory-listed calibration range, it goes into alarm and the Alarm LED latches on. If the detector is too sensitive, the LED rapidly flashes six times (once every half second) and the detector signals an alarm. If the detector is not sensitive enough, the LED slowly flashes four times, once every 2 seconds, and the detector signals an alarm. If the detector does not operate, it does not signal an alarm. Voltage measurement test: Use a D1005 Test Cable and a digital voltmeter to measure the voltage and compare the results with the factory-listed sensitivity range. Region Certification USA UL UROX: Smoke - Automatic Fire Detectors (UL268 and A), UROX7: Smoke - Auto- matic Fire Detectors Certified for Cana- da (cULus), CSFM see our website NYC- 274-93-E, Vol. VII MEA MSFM Hong Kong HKFSD D263\TH\THS Installation/configuration notes Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D263 Series detectors: Category Product ID Product Description Control Bosch Security Systems makes no claim written, oral, or Panels implied that the D263 Series detectors work with any two-wire control panels except those specified in the Control Panel Compatibility chart in Technical Service Note ON: 31866). Modules D132B Reversing relay module Mounting The detector has a mounting plate that attaches on a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (ISO 4 mm2) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. Parts included Quanti Component ty 1 Detector 1 Lit pack - Installation Manual, Technical Service Note on installation Technical Environmental Considerations Radio Frequency No alarm on critical frequencies in the Interference (RFI) range of 26 MHz to 950 MHz. Immunity: Relative Humidity: Up to 93%, non-condensing Temperature (operating): +32°F to + 120°F (0°C to +40°C) Mechanical Properties Dimensions (Diameter x H): 5 in. x 2 in. (12.7 cm 5.1 cm) Material: High impact, fire retardant ABS plastic Relay Contacts Auxiliary Form C: 1 A, 120 VAC/30 VDC at 1 A, 30W maximum Power Requirements [Current Draw (alarm).-) Determined by control panel -rent Draw (standby) '0.080 mA at 12 V, 0.1 mA maximum Current Draw (start-up) .0.12 mA [Current Draw (trouble):' 10.1 mA maximum, Power-up Time: 22 sec maximum RMS Ripple (maximum): 25% of DC input Voltage (stand-by): 8.5 VDC to 33 VDC Ordering liii'] 1i1P.14[s]i b263 two-Wire Smoke Detector' - - - 'Two-wire photoelectric smoke detector. Order number b26 D2631H Two-Wire Smoke/Heat Detector Two-wire photoelectric smoke detector with a 135°F (57°C) heat sensor. Order number D263TH 3 1 D263 Photoelectric Smoke and Smoke and Heat Detectors D263THS Two-Wire Smoke/Heat Detector with Sounder Ttwo-wire photoelectric smoke detector with a 135°F (57°C) heat sensor and a sounder. Order number D263THS Accessories D1005 Test Cable Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range Order number D1005 DT-2 Detector Removal Tool Use the DT-2 to remove, replace, or test the detector head Order number DT-2 TP280 Trim Plate For retrofit and remodeling purposes; 16.2 cm (6 in.) diameter Order number TP280 C Represented by: American: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Busch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O. Box 80002 Systems 203 Building, No. 333 Fuquan Road Via Anhanguera, Km 98 Fairport, New York, 14450, USA 5637 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone: -1 800 289 0096 Phone: 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Say Paulo, Brazil Fax: +1585 223 9180 security.sutes@us.kosch.com Fax: +3140 2577 330 emea.securitysystems@bosch.com Phone: +6165712808 Fax: *65 6571 2699 200335 China Phone *86 21 22181111 Phone: +55 19 2103 2860 Fax: *55 19 2103 2862 • www.boschsecurity.as www.boschsecurity.com apr.secaritysystems@bosch.com Fax: 086 21 22182398 latam.boschsecarity@bosch.com www.boschsecurity.asia www.boschsecurity.com.cn www.boschsvcxrity.com 0 Bosch Security Systems 2015 ) Data subject to change without notice 2700390283 1 en, V9, 14. Aug 2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1615:0134 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: Jon.wolski@us.bosch.com DESIGN: Models D285, D2850H, 0285TH, 0263, D2631H, 0273, D273TH, D273THS, D263THC, 0263TH5, D273THR, D273THC, D27315, D273THCS, D273THSR, D273THE, D273E5 and D273THES smoke detectors. Model D285TH, 0263TH and D273THxx employ an integral 1350 fixed temperature heat detector. This heat sensor is intended for use only as a supplemental device to assist the smoke detector. *Model 0285 series are separable detector heads which operate with separable base Models 0287, 0288, 0292, 0293A, D293E and D2935. *Models 0263 and D273 series detectors are nonseparable detector heads with terminal blocks and do not operate with separable bases. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. is MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control unit. Models 0285 and 0285TH are intended for use with separately listed bases. Model D285DH is intended for use with separately listed Duct Smoke Detector Housing Model 0341 or 0342 (CSFM Listing No. 3240-1615:181) or Model D340 (CSFM Listing No. 3240-1615:184). Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7272-0801:162 *Rev. 05-29-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Selectable-Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrAlert Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Field-selectable candela settings on wall units: 135, 150, 177, and 185 Rotary switch for low frequency sounder tone Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting R11gM1U--6-Ej - - D 3mv A111111111F.L111111111111 k' W4! The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount low frequency sounder, and low frequency sounder strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for low frequency sounder tones. Agency Listings SIGNAUNG @ <~> MFA LISTED APPROVED approved S4011 (sounder) S5512 (strobes) 3047563 MEA452-05-E 7135-1653:0223 7125-1653:0224 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-iflch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit ° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync.CircuitlM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync.Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/RNR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm Lx 119 mm W 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm Lx 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm Lx 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. [I UJI Current 1IDraw IData Max. Strobe Current Draw (n 8-17.5 Volts 16-33 Volts High 135 Candela Range 150 DC FWR DC FWR NA NA 228 207 NA NA 246 220 177 NA NA 281 251 UL Max. Low Frequency 185 Current Draw (rnA NA RMS) NA 286 258 Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 'Temporal High 191 262 1,138' 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 thuMax. Currenta 16-33 Volts '1 High11. *TI 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output (dBA) Switch Position Sound Pattern 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant DC FWR Anechoic DC FWR 1 Temporal 76 76 76 76 76 76 86 86 2 • Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 Sounder ratings provided are for continuous voltage as provided by the NAC 0 4.7 in. 6.4 in. Alert Advance Dimensions Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information It'1[iIi[1 Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF; Low Frequency Sounder, White), Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White Notes: 'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. T'S\ "STEM SENSOR Ohio Avenue • St. Charles, IL 60174 ©20t4 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 duct specifications subject ts Change wthoutflohce.Vtatsystemsensor.corfl for current product information, including the latest version of this data sheet www.systemsensor.com AVDS16402 • 1/14 [I: S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM CAL FIRE FIRE LISTING SERVICE LISTING No. 7135-1653:0223 Page 1 of I CATEGORY: 7135— AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models HR-LF and HW-LF horns. Intended for indoor use and suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal. *These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to manufacturer's Installation Manual for details. *Rev 07-22-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed - the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S r F It SYSTEM $ SENSOR® Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications Spectrkert@ Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNAUN S @ <~> MEA LISTED APPROVED approved 7125-1653:186 (indoor strobes) 7125-1653:198 )horn strobes, 54011 )chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 )strobeo) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also fount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuif° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently cf the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate i flash per second Nominal Voltage Regulated 12 DC/FvVR or regulated 24 DC/RNR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'L x 4.7"W x 2.5'D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7"W x 1.3'D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 Cd. 0 UL Current Draw Data S 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela (15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 ',15f75"30 75 95 110 115 (Temporal Highi 137 147 79 190 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t • Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. S SpectrAlert Advance Dimensions .j Wall-mount horn strobes SpectrAlert Advance Ordering Information Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUF_GO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W, (2-Wire Horn Strobe, Standard cd, White) P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Model Description Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW, Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75,30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. S' SIvsoR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visitsystemoensor.corn siivi 3825 Ohio Avenue • St. Charles, IL 60174 02014 SysteosSensor for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS10201 • 1/14 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, 134W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Hom/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR S INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Models Available Strobes Red White S1224MC S1224MCW S1224MCP S1224MCPW S1224MCK S1224M CSP Horn/Strobes Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP Horns Red White H12/24 H12/24W H12/24K Product Overview Operates on either 12V or 24V SpectrAlert® Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fea- Widest range of candela options: tures that Include the widest range of candela options available and the capability to 12V: 15 and 15/75 candela recognize and self-adjust for either 12 or 24 volt operation. With an overall feature 24V: 15, 15/75, 30, 75, 110 candela set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name. S Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClickTM Synchronizable with MDL SyncoC!rcu!tTm module Meets UL1971, NFPA72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patented voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. 0 @ LISTED 71.25-1209:222 S5512 54011 7135.1209:223 MEA approved 122.02-E 3014150 126-02-E Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4 x 4 X 11/2" back box or a single gang 2 x 4" x 1/8" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync-Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync•Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16 x 4"/16" x 2'/8" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Specifications Walk Test SpectrAlert horn/strobe and horn only work on "walk tests" with time dura- tions of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5 x 5/ x 215/i6 Strobe and horn/strobe with small footprint plate 3/8 x 5/e x 2/16" Horn with universal mounting plate 5 x 5/ x Horn without mounting plate 215/16" X 5/16 x 1/16" Weight, horn only 7.2 oz. Weight, strobe and horn/strobe 8.8 oz. Mounting 4" x 4 X 11/2 or 2" x 4 x 1/8 standard boxes Operating Temperature (Indoor) 32°F to 120°F (0°C to 49°C) Maximum humidity (Indoor) 95% as tested per UL464 Outdoor (K Series) Operating Temperature —40°F to 151°F (-40°C to 66°C) Outdoor rating NEMA 3R (per UL 50) Voltages 12 or 24VDC and FWR1 unfiltered Operating voltage range 12V: 8-17.5V; 24V: 16-33V Operating voltage range (with Sync.Circuit module, MDL)2 12V: 9-17.5V; 24V: 17-33V U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 S Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. The MDL causes a one-volt voltage drop in the notification appliance circuit. Table 1-A: SpectrAlert Strobe UL Max. Current Draw Candela Setting FWR Operating Current-Strobe (mA RMS) DC Operating Current-Strobe (mA RIVIS) 8.17.5V 16-33V 8-17.5V 16-33V 15 112 64 127 59 15/75 135 74 127 69 30 93 90 75 158 160 110 208 209 Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) Selectable Horn Tones DC FWR 8-17.5V 16-33V 8-17.5V 16-33V Temporal Low Volume Electromechanical 15 23 13 23 3000 Hz Interrupted 15 33 13 23 High Volume Electromechanical 36 53 20 44 3000 Hz Interrupted 43 57 21 40 Non- Temporal Low Volume Electromechanical 16 37 19 29 3000 Hz Interrupted 16 32 18 33 High Volume Electromechanical 38 49 46 49 3000 Hz Interrupted 1 44 56 42 58 Table 1-C: I2VDC Horn/Strobe UI Max. Current Draw Measurements (mA RMS) I Temporal Low Volume High Volume Candela Setting Electromechanical 3000 Hz Electromechanical 3000 Hz 15 111 111 112 112 15/75 127 127 126 129 Non-Temporal 15 113 112 114 115 15/75 128 128 130 134 Explanation of Published Voltage, Current, and SPI Specifications In May 2004 Underwriters Laboratories changed standard UL 1971 to require that operating current measuremments are made using RMS (root mean square) instead of peak or average values. RMS measurements more accurately predict the power consumption of a device since they take into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS cur- rent is the maximum operating current of that device within its operating voltage range. This current maximum may or may not occur at the endpoints of the voltage range. Similarly, UL tests the audibility of devices in accordance with UL 464 by measuring them across the operating volt- age range to determine the minimum sound pressure level produced at any particular setting. During May 2004, UL also changed the way they list the voltage range of a device. All 12V products will be listed between 8 - 17.5V and all 24V products will be listed between 16 - 33V. Those devices are considered "regulat- ed". Any product that does not operate within these ranges will be listed as a "special application" with its operating voltage specified on the device. Notes Current draw for strobe-only products is shown in Table 1-A. Current draw for horn-only products is shown in Table 1-13. I2VDC 2-wire horn/strobe current is shown in Table 1-C. 24VDC 2-wire horn/strobe current draw is shown in Table 1-D. Current draw for other horn/strobe power supplies can be calculated by adding the strobe current in Table 1-A to the horn current in Table 1-13 from the chosen settings. Table 1-D: 24VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS) Temporal Low Volume High Volume Candela Setting Electromechanical 3000 Hz Electromechanical 3000 Hz 15 71 70 73 75 15/75 86 85 87 88 30 99 98 100 100 75 166 166 167 170 110 209 209 210 213 Non-Temporal 15 74 74 79 82 15/75 86 88 93 96 30 101 101 107 110 75 167 167 173 176 110 213 213 1 218 222 SpectrAlert Strobe Candela Selections For strobe candela selection, adjust slide switch located on the rear of the product while watching the viewing window on the side of the reflector. Permissible Candela Settings Candela operating Voltage Setting 12V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK Viewing V #8-36 x 1/2 Flat Head Screw (4 total) ,-- slot Paper Liner For Plate Gasket Locking Rib A0135.02 SpectrAlert Horn Sound Measurements (dBA) Selectable Horn Tones 8-17.SV 16-33V Temporal Low Volume Electromechanical 67 75 3000 Hz Interrupted 68 75 High Volume Electromechanical 71 80 3000 Hz Interrupted 72 81 Non- Temporal Low Volume Electromechanical 71 79 3000 Hz Interrupted 72 79 High Volume Electromechanical 76 84 3000 Hz Interrupted 77 86 DIP Switch Operation on P1224MC Factory OFF ON Default DIP Switch Low 1 i.i High I raI Temporal Ii I Non-Temporal ls_1 I Electromech. II I 3000Hz [_]Base(rear) A0110-00 SpectrAlert Ordering Information Model Description P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, outdoor P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, FUEGO" housing S1224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt, white 51224MCP Selectable Output Strobe, 12/24 volt, red, plain housing S1224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing SI224MCK Selectable Output Strobe, 12/24 volt, red, outdoor S1224MCSP Selectable Output Strobe, 12/24 volt, red, "FUEGO" housing Typical weatherproof mounting with universal plate Model Description H12/24 Horn, 12/24 volt, red H12/24W Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red, outdoor Accessories MDL Sync.Circuit Module, red MDLW Sync.Circuit Module, white MDLWA Sync *Circuit Module, white, Canadian model S-MP Small Footprint Mounting Plate, red, for single- gang back box S-MPW Small Footprint Mounting Plate, white, for single- gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box Notes All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor - Far East System Sensor - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor In Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 0 2005 System Sensor. The company reserves the right to change product speiflcations without notice. A05-0325-006.9/05.#1526 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0252 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.esteban@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. Models ST-MC-CW, ST-HMC-CW, ZR-MC-CR, ZR-MC-CW, ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd • ZR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes I minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -w are wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: 9-10-2007mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division www.boschsecurity.com 0BOSCH Invented for life Single or dual action Terminal connections Gold-plated alarm contacts for corrosion resistance Surface or weatherproof back boxes TheM M-100family are versatile, high-quality, metal fire alarm manual stations. Single-action or dual-action models are available. All models come with a key lock and contain gold-plated contacts to resist corrosion. Operation Single-action When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft (15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual-action With the dual-action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Region Certification USA UL UNIU: Boxes, Non-Coded (UL38), UNIU7: Boxes, Non-Coded Certified for Canada (cULus) CSFM see our website NYC- 382-94-E, Vol. VI MEA Compatibility Information These manual stations are compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations These manual stations can be surface mounted on either the FMM-100BB-R Surface-mount Back Box or the FMM-100WPBB-R Weatherproof Back Box. They can also be flush mounted on a standard single-gang back box. 51 Notice When properly mounted on the FMM-100WPBB-R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wheelchair access and less than 54 in. (1.3 m) above the floor for side wheelchair access. Parts Quant. Component 1 Manual station 1 D102 Key (1358 key) 1 FMM-100GR Acrylic Break Rod 1 Hardware pack 1 Technical Literature pack .1.I1sI[JTTI[.].. Environmental Relative Humidity: 90% at +100°F (+38°C) Temperature -40°F to + 150°F (-40°C to +66°C) (operating): Mechanical Color: Red Dimensions 4.75 in. x 3.25 in. x 1.1 in. (HxWxD): (12 cm x 8.3 cm x 2.8 cm) Material: die-cast metal Inputs Switch Rating: 1 A at 30 VDC or 125 VAC (FMM-IOOSATK Single-action Manual Station (red)) Versatile, high-quality, metal single-action fire alarm ç?manual station with key lock and go!d-plated contacts Order numberFMM-100SATK FMM-100SATK-NYC Single-action Manual Station for New York City Versatile, high-quality, metal single-action fire alarm manual station for New York City with key lock and gold-plated contacts Order number FMM-100SATK-NYC FMM-100DATK Dual-action Manual Station (red) Versatile, high-quality, metal dual-action fire alarm manual station with key lock and gold-plated contacts Order number FMM-100DATK Accessories D102 Replacement Key Replacement key (#1358) for LOCK-1358 and the D1O1 lock. Order number D102 FMM-100BB-R Surface-mount Back Box (red) Red cast-metal back box Order number FMM-100BB-R FMM-100WPBB-R Weatherproof Back Box (red) Red cast-metal weatherproof back box Order number FMM-100WPBB-R FMM-100GR Scored Acrylic Break Rods Scored acrylic rods (12 per package) Order number FMM-100GR 3 I FMM-100 Die-cast Metal Fire Alarm Manual Stations Represented by Americas Bosch Security Systems, Inc. 130 Periston Parkway Fairport, New York, 14450, USA Phone: -1800 289 0096 Fax: +1585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5617 BA Eindhoven, The Netherlands Phone: +31 40 2577 284 Fax: +3140 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific; Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishas Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.secoritysystems@bosch.com www.boschsecurity.asia China Bosch )Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquas Rood North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: *86 21 22182398 www.bxschsecurity.com.cn America Latins: Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sax Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Busch Security Systems 2014 ) Data subject to change without notice 2708627339 1 en, V2, 11. Aug 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1615:0224 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FMM-100, followed by DAT (Dual Action with terminal strip) or SAT (Single Action with terminal strip) may be followed by K or K-NYC (key lock with single contact) or 2CK (Key lock with dual contacts) noncoded manual pull stations. FMM-100BB indoor back box, Suitable for outdoor use when installed with Model FMM-1 OOWPBB back box. *FMM100DBBR surface mount deep back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Only Models FMM-100DATK, -100SATK, -100SAT2CK manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Revised 09-01-2016 dc ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Copyrtht 2013 National Fire Protection Association (NFPA). Ucensed, by agreement, for Individual use and single download on November 13,2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact Ilcenslng@nfpa.org. DOCUMENTATION 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the System installation contractor at the time of system acceptance and approval. - It shall be permitted to m0d14' this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date:10/18/2017 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Quarry Creek Apts Address: 2925 Luiseno Way Carlsbad CA 92010 Description of property: Building 1 Name of property representative: Address: Phone: - Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Service organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 7607473050 Fax: 7607477561 E-mail: gwebster@hcisystems.net Testing organization: HCI Systems Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607000 Fax: 858-560-7007 E-mail: gwebster@hcisystems.net Effective date for test and inspection contract: Monitoring organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607007 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Account number: Al 63925 Phone line 1: NA Phone line 2: NA Means of transmission: Cellular dailer Entity to which alarms are retransmitted: Phone: NA DOCUMENTATION On-site location of the required record documents and site-specific software: FACP Room. DESCRIPTION OF SYSTEM OR SERVICE Permit number: _F201 60036 This is a: 'New system - Modification to existing system NFPA 72 edition: 201 4.1 Control Unit Manufacturer: Bosch 4.2 Software and Firmware Firmware revision number:____________________________ 4.3 Alarm Verification Number of devices subject to alarm verification: 0 02012 National Fire Protection Association FIGURE 7.8.2(a) System Record of Completion. (SIC-FUN) Model number: FPD7024 This system does not incorporate alarm verification. Alarm verification set for 0 seconds NFPA 72(p. 1 of 3) 2013 Edition Copyright 2013 National Firs Protection Association (NFPA). Licensed, by agreement, for Individual use and single download on November 13, 2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact llcenslng@nfpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 volt Control panel amps:1.3 amps Overcurrent protection: Type: Fuse Amps: 5A 250V SLO-BLO Branch circuit disconnecting means location: Circuit Breaker Number: CIA 16 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant:NA Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 52 Control Unit Ur This system does not have power extender panels U Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B 1 Device Power Initiating Device B 1 Notification Appliance Other (specify): REMOTE ANNUNCIATORS Type Location NA INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Hard Wire Alarm NA Smoke Detectors 1 Hard Wire Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches 1 Hardwaire Alarm NA Tamper Switches 1 Hard Wire Supervisory INA © 2012 National Fire Protection Association NFPA 72 (p. 2 o13) FIGURE 7.8.2(a) Continued 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13, 2013 to SIAPROCI for designated user PATRICiO FUSTILLOSI. No other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use contact licenslng@nlpa.org. DOCUMENTATION 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date:10/18/2017 Supplemental Pages Attached:_________ PROPERTY INFORMATION Name of property: Quarry Creek Apts Address: 2935 Luiseno Way Carlsbad CA 92010 Description of property: Building 2 Name of property representative: Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: _8585607000 Fax: 858-560-7007 E-mail: _gwebster@hcisystems.net Service organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 760-747-3050 Fax: 7607477561 E-mail: gwebster@hcisystems.net Testing organization: HCI Systems Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607000 Fax: 8585607007 E-mail: gwebster@hcisystems.net Effective date for test and inspection contract: Monitoring organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607007 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Account number: Al 63925 Phone line 1: NA Phone line 2: NA Means of transmission: Cellular dailer Entity to which alarms are retransmitted: NA Phone: NA DOCUMENTATION On-site location of the required record documents and site-specific software: FACP Room. DESCRIPTION OF SYSTEM OR SERVICE This is a: 'New system - Modification to existing system NFPA 72 edition: 201 4.1 Control Unit Manufacturer: Bosch 4.2 Software and Firmware Firmware revision number: Permit number: _F201 6-0037 Model number: FPD7024 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for 0 seconds © 2012 National Fire Protection Association NFPA 72 (p. 1 of 3) FIGURE 7.8.2(a) System Record of Completion. (SIC-FUN) 2013 Edition ria Copyrig,ht 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and Single download on November 13. 2013 to SIAPROCI for designated user PATRICLO FUSTILLOSI. No other reproduction or transmission in any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact ftcensing@nfpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 volt Control panel amps: 1.3 amps Overcurrent protection: Type: Fuse Amps: 5A 250V SLO-131O Branch circuit disconnecting means location: Circuit Breaker Number: CIR 16 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant:NA Calculated capacity of secondary power to drive the system: In standby mode (hours):24 In alarm mode (minutes): 5 5.2 Control Unit Ur This system does not have power extender panels O Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B 1 Device Power Initiating Device B 1 go Notification Appliance Y 1 Other (specify): REMOTE ANNUNCIATORS Type Location NA INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Hard Wire Alarm NA Smoke Detectors 1 Hard Wire Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches 1 Hardwaire Alarm NA Tamper Switches 1 Hard Wire Supervisory NA © 2012 National Fire Protection Association NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued 141 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI for designated user PA1RiCi0 FUSTiLLOSI. - ' No other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact ilcensing@nfpa.org. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 40 Mini Horns Visible Strobe Combination Audible and Visible Horn Strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown Fire/Smoke Dampers 0 Door Unlocking 0 Elevator Recall 0 Elevator Shunt Trip 0 INTERCONNECTED SYSTEMS i This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampler Date:_____________ Organization: HCI Systems Title: Lead Tech Phone: 61 98239552 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampler Date:_____________ Organization:_HCI Systems Thin: Lead Tech Phone: 6198239552 12.3 Acceptance Test Date and time of acceptance test:_________________________________________________________________ Installing contractor representative: Stephen Sampier Testing contractor representative: _Stephen Sampler Property representative:___________________________________________________________________________ AHJ representative: 02012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 7.8.2(a) Continued 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For Inquires or to report unauthorized use contact llcenslng@nfpa.org. DOCUMENTATION 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date:10/18/2017 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Quarry Creek Apts Address: 2945 Luiseno Way Carlsbad CA 92010 Description of property: Building 3 Name of property representative: Address: Phone: - Fax: E-mail: INSTALLATION, SERVICE, ESTING, AND MONITORING INFORMATION Installation contractor: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Service organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 760-747-3050 Fax: 7607477561 E-mail: gwebster@hcisystems.net Testing organization: HCI Systems Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607000 Fax: 858-560-7007 E-mail: gwebster@hcisystems.net Effective date for test and inspection contract: Monitoring organization: HCI Systems Inc 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607007 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Account number: Al 63925 Phone line 1: NA Phone line 2: NA Means of transmission: Cellular dailer Entity to which alarms are retransmitted: J± Phone: NA DOCUMENTATION On-site location of the required record documents and site-specific software: FACP Room. DESCRIPTION OF SYSTEM OR SERVICE This is a: .' New system - Modification to existing system NFPA 72 edition: 201 4.1 Control Unit Manufacturer. Bosch 4.2 Software and Firmware Firmware revision number:_______________________________ 4.3 Alarm Verification Permit number: _F201 6-0038 Model number: FPD7024 This system does not incorporate alarm verification. Number of devices subject to alarm verification: _0 Alarm verification set for .Q seconds © 2012 National Fire Protection Association NFPA 72 (p. lot 3) FIGURE 7.8.2(a) System Record of Completion. (SIG-FUN) 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for Individual use and Single download on November 13, 2013 to SIAPROCI for designated user PATRICIO FUSTIL.LOSI. No other reproduction or transmission in any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact llcensing@nlpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 volt Control panel amps: 1 .3 amps Overcurrent protection: Type: Fuse Amps: 5A 250V SLO-BLO Branch circuit disconnecting means location: Circuit Breaker Number: CIR 16 5.1.2 Secondary Power Type of secondary power:Battery Location, if remote from the plant:NA Calculated capacity of secondary power to drive the system: In standby mode (hours):24 In alarm mode (minutes): 5 5.2 Control Unit Ck This system does not have power extender panels U Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B 1 Device Power y Initiating Device B 1 Notification Appliance Other (specify): REMOTE ANNUNCIATORS Type Location NA INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Hard Wire Alarm NA Smoke Detectors 1 Hard Wire Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Wat.erflow Switches 1 Hardwaire Alarm NA Tamper Switches 1 Hard Wire Supervisory NA © 2012 National Fire Protection Association NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPHOCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact Ilcenslng@nfpa.org. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 24 Mini Horns Visible Strobe Combination Audible and Visible Horn Strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown Fire/Smoke Dampers 0 Door Unlocking 0 Elevator Recall 0 Elevator Shunt Trip 0 INTERCONNECTED SYSTEMS i This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampier Date:_____________ Organization: HCI Systems Title: Lead Tech Phone: 619-823-9552 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampier Date:_____________ Organization:_HCI Systems Title: Lead Tech Phone: 6198239552 12.3 Acceptance Test Date and time of acceptance test:________________________________________________________________________ Installing contractor representative: Stephen Sampier Testing contractor representative: Stephen Sampier Property representative:____________________________________________________________________________________ AHJ representative: @2012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 7.8.2(a) Continued 2013 Edition Wd Copyrit 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. Ir No other reproduction or transmission In any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact ltcenslng@nlpa.org. DOCUMENTATION 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 10/18/2017 Supplemental Pages Attached:__________ PROPERTY INFORMATION Name of property: Quarry Greek Apts Address: 2955 Luiseno Way Carlsbad CA 92010 Description of property: Building 4 Name of property representative: Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Service organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: gwebster@hcisystems.net Testing organization: HCI Systems Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail: gwebster@hcisystems.net Effective date for test and inspection contract:___________________________________________________________ Monitoring organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 8585607007 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Account number: A163925 Phone line 1: NA Phone line 2: NA Means of transmission: Cellular dailer Entity to which alarms are retransmitted: NA Phone:-NLA DOCUMENTATION On-site location of the required record documents and site-specific software: FACP Room. DESCRIPTION OF SYSTEM OR SERVICE This is a: -, New system Modification to existing system Permit number: _F20 16-0039 NFPA 72 edition: 201 4.1 Control Unit Manufacturer: Bosch 4.2 Software and Firmware Firmware revision number:... 4.3 Alarm Verification Number of devices subject to alarm verification:.P © 2012 National Fire Protection Association FIGURE 7.8.2(a) System Record of Completion. (SIG-FUN) Model number: FPD7024 This system does not incorporate alarm verification. Alarm verification set for 0 seconds NFPA 72 (p. 1 of 3) 2013 Edition no Copyrlgirt 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI fordesignated user PATRICIO FUS11L.LOS. No other reproduction or transmission in any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact iicenslng@nfpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 volt Control panel amps: 1 .3 amps Overcurrent protection: Type: Fuse Amps: 5A 250V SLO-131O Branch circuit disconnecting means location: Circuit Breaker Number: CIR 16 5.1.2 Secondary Power Type of secondary power:Battery Location, if remote from the plant:NA Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit ' This system does not have power extender panels O Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B 1 Device Power y Initiating Device B 1 Notification Appliance Other (specify): REMOTE ANNUNCIATORS Type Location NA INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Hard Wire Alarm NA Smoke Detectors 1 Hard Wire Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches 1 Hardwaire Alarm NA Tamper Switches 1 Hard Wire Supervisory INA © 2012 National Fire Protection Association NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued PRO 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Ucensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI for designated user PAIRICID FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact llcensing@nlpa.org. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 28 Mini Horns Visible Strobe Combination Audible and Visible Horn Strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown Fire/Smoke Dampers 0 Door Unlocking () Elevator Recall Elevator Shunt Trip 0 INTERCONNECTED SYSTEMS / This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampler Date:_____________ Organization: HCI Systems Title: Lead Tech Phone: 61 98239552 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampler Date:_____________ Organization: _HG! Systems Title: Lead Tech Phone: 619-823-9552 12.3 Acceptance Test Date and time of acceptance test:________________________________________________________________________ Installing contractor representative:Stephen Sampler Testing contractor representative:Stephen Sampler Property representative:____________________________________________________________________________________ AHJ representative: © 2012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 7.8.2(a) Continued 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and stogie download on November 13,2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For Inquires or to report unauthorized use, contact Hcenslng@nlpa.org. DOCUMENTATION 72-7 000 Lfro SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 10/18/2017 Supplemental Pages Attached:__________ PROPERTY INFORMATION Name of property: Quarry Creek Apts Address: 2965 Luiseno Way Carlsbad CA 92010 Description of property: Building 5 Name of property representative: Address: Phone: Fax: E-mail:___________________________ INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: HCI Systems Inc Address: 4585 Murphy Canyon Road, San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail: nwebster@hcisystems.net Service organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 760-747-3050 Fax: 760-747-7561 E-mail:_gwebster@hcisystems.net Testing organization: HCI Systems Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7000 Fax: 858-560-7007 E-mail: gwebster@hcisystems.net Effective date for test and inspection contract: Monitoring organization: HCI Systems Inc Address: 4585 Murphy Canyon Road. San Diego, CA 92123 Phone: 858-560-7007 Fax: 858-560-7007 E-mail:_gwebster@hcisystems.net Account number: A163925 Phone line 1: NA Phone line 2: NA Means of transmission: Cellular dailer Entity to which alarms are retransmitted: NA Phone: NA DOCUMENTATION. On-site location of the required record documents and site-specific software: FA'CP Room. DESCRIPTION OF SYSTEM OR SERVICE This is a: 'New system Modification to existing system Permit number: F201 60040 NFPA 72 edition: 9013 4.1 Control Unit Manufacturer: Bosch Model number: FPD7024 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: _0 Alarm verification set for 0 seconds 02012 National Fire Protection Association NFPA 72 (p. 1 of 3) FIGURE 7.8.2(a) System Record of Completion. (SIG-FUN) 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and Single download on November 13, 2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission in any form permitted without written permission of NFPA. For Inquires or to report unauthorized use contact llcensing@nfpa.org. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 volt Control panel amps:1 .3 amps Overcurrent protection: Type: Fuse Amps: 5A 250V SLO-BLO Branch circuit disconnecting means location: Circuit Breaker Number: CIA 16 5.1.2 Secondary Power Type of secondary power:Battery Location, if remote from the plant:NA Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit Ur This system does not have power extender panels U Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B 1 Device Power y Initiating Device B 1 Notification Appliance Other (specify): REMOTE ANNUNCIATORS Type Location NA INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Hard Wire Alarm NA Smoke Detectors 1 Hard Wire Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches 1 Hardwaire Alarm NA Tamper Switches 1 Hard Wire Supervisory NA © 2012 National Fire Protection Association NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued al 2013 Edition Cooyrlght 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on November 13,2013 to SIAPROCI for designated user PATRICIO FUSTILLOSI. No other reproduction or transmission In any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact ltcenslng@nlpa.org. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible 10 Mini Horns Visible 2 Strobe Combination Audible and Visible Horn Strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown Fire/Smoke Dampers 0 Door Unlocking 0 Elevator Recall o Elevator Shunt Trip 0 INTERCONNECTED SYSTEMS i This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Stephen Sampler Date:______________ Organization: HCI Systems Title: Lead Tech Phone: 619-823-9552 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein, Signed: Printed name: Stephen Sampler Date:______________ Organization:_HCI Systems Title: Lead Tech Phone: 6198239552 12.3 Acceptance Test Date and time of acceptance test:_________________________________________________________________ Installing contractor representative:Stephen Sampler Testing contractor representative: Stephen Sampler Property representative:________________________________________________________________________________ AHJ representative: © 2012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 7.8.2(a) Continued 2013 Edition