HomeMy WebLinkAbout5823 NEWTON DR; ; FPC2017-0205; Permitibtyof PERMIT REPORT Carlsbad Print Date: 12/14/2020 Permit No: FPC2017-0205 Job Address: 5823 NEWTON DR, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120504300 Track #: Applied: 07/24/2017 Valuation: $1,340,650.75 Lot #: Issued: 08/10/2017 Occupancy Group: Project #: Finaled Close Out: 12/14/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: THERMO FISHER DESIGN CENTER TI -FIRE ALARM EXPANSION FPContractor: JMG SECURITY SYSTEMS 17150 NEWHOPE ST, # 109 FOUNTAIN VALLEY, CA 92708-4273 (714) 545-8862 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 760-602-8561 f I www.carlsbadca.gov HIGHLIGHTED SET UL & FM Certificates of Compliance Cut Sheets and CSFM listings technologies TM Thermo Fisher Scientific - Design Center Tenant Improvements 5823 Newton Drive, Carlsbad, CA 92008 Installation Company: 7-zJMGSYSTEMS FILE Copy SECURITY Our service is your security. TM 17150 Newhope Street Fountain Valley, CA 92708 FPC20I 7-0205 (714) 545-8882 5823 NEWTON DR 01 U Applicant ID No: 257057-001 Service Center No: I Expires: 31-MAR-2018 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service Company: (257057-001) ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: (257057-001) ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category N BP103071 CRZM ' Monitoring Stations, National Industrial Security S8126.1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station / / If ***THIS CERTIFICATE EXPIRES ON 31MAR2018**,* 'LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE MR T SHUFF Applicant Subscriber No: 257057-001 ADVANCED PROTECTION INDUSTRIES INC. Service Center Number: 1 DBA NATIONAL MONITORING CENTER Service Contract No: - 25341 Commerce ntre Dr ACTIVE LISTINGS Lake Forest CA 92630 CCN File No. Vol. No. UUFX S8126 1 CRZM BP10307 1 Listed Service From: LAKE FOREST, CA Alarm Service Comoanv: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 01-APR-15 Service Center: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 4 D SILENT KNIGHT by Honeywell lntelliKnight® Model 5820XL Addressable Fire Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD and SK SLC devices on a FACP. IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the IntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The IntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows®- based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA @ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505-DTS-K Remote test switch. Used with 5D505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our Made in America product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203)484-7161, Fax: (203)484-7118. www.silentknight.com. © 2012 Honeywell International Inc. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel V*xbm Based Fadity Monag mud Sotwars Ir3ws Oned t*/Downtesd Sotwars InteIIiKnight 5820XL Addressable Fire Alarm System SK (System Sensor) Protocol Devices —+M 14 FC-232 10 CosEittle CS ____ Receiver __________ — A*oinotori $cnuT• tftrnet 5K-202U0 Conoe.ti,n (narMorm P CommunicMor LCFpndor 5K.r UK 10 $K4eam.T M*oIo AC3tG Bflotedor Modulo Module Interfuce Rthei I Module Model. O I I U5.4ur5IS4 I I 1)15 tT• 6000 to control up to 4 r — LEDncodor D SILENT KNIGHT by Honeywell Analog/Addressable Devices with Hochiki (SD) Protocol SD505-AIS An ionization smoke detector that has a sampling chamber and reference chamber for high stability .. and for a variety of applications ., f \ where early warning of trouble from \ / super-heated or flaming combustibles is desired. Presence of visible smoke or invisible gases greatly influences the current flow in SD505-AIS the sampling chamber, changing the (Base not included) voltage ratio between the chambers. The difference is amplified inside the detector. When reaching a critical level, the detector triggers an alarm. SD505-DUCT A addressable duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. This duct detector is housed in a heavy duty metal housing with a preinstalled SD505-APS photoelectric smoke detector. SD505-DUCT has an air velocity rating from 300 feet per minute to 4,000 feet per minute. Order 5D505-T2, SD505-T5, or SD505-T1O air sampling tubes separately. SD505-DUCTR A duct smoke detector that detects smoke and products of combustion present in air moving through an HVAC duct. The SD505- DUCTR provides a fully programmable Form C contact. This duct detector is housed in a heavy duty metal housing with a preinstalled SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the detector communicates the condition to the SD505-DUCTR FACP. The built-in relay module then turns off fans, blowers, and other devices. SD505- DUCTR has an air velocity rating from 300 feet per minute to 4,000 feet per minute Order SD505-T2, SD505-T5, or 5D505-T10 air sampling tubes separately. Optional 5D505-DTS-2 remote test switch available. SD Devices SD devices are intelligent analog/addressable devices for use with the following lntelliKnight addressable fire alarm control panels (FACP5): 5820XL, 5808 and 5700. SD detectors, modules, and accessories communicate to the FACP over the signaling line circuit loop (SLC loop) using a two wire connection. Shielded or twisted wire is not required. Up to 127 addressable SD devices can communicate with the FACP on a single SLC loop. Any combination of addressable SD devices and SD modules can be used on a single SLC loop. The assortment of SD detectors, modules, and accessories that are compatible with lntelliKnight addressable FACPs are described below. For detailed information on SD devices, see the device specification sheet. Detectors SD505-APS A photoelectric smoke detector. SD505-APS has an LED light source and silicon photo diode receiving element. The detector features automatic drift compensation for contamination and a simple detector calibration test procedure that can be run at the FACP or remotely using 5650/5651 Silent Knight Software Suite. SD505-APS (Base not included) SD505-AHS A fixed temperature heat detector that uses an externally mounted thermistor with a specially designed cover that protects the !31 thermistor while allowing maximum air flow. SD-505-AHS offers a programmable trip point temperature from .1 3511F - 150°F '. - (57°C - 650C). This detector is well suited for environments where smoke detectors 5D505-AHS cannot be used because of the presence of (Base not included) steam or cooking fumes, such as in a kitchen. SD Devices Modules SD500.AIM A dry contact input module that acts as an _ lHI9j interface to contact devices, such as waterflow switches and pull stations. The ° U SD500-AIM supports Class B supervised f wiring.This module monitors for alarm contact closures and open circuit wiring fault conditions. Mounts in a 4" square box. sD500-AIM SD500-MIM A compact and light weight monitor module that acts as an interface to contact devices, such as water-flow switches and pull stations. The SD500-MIM supports Class B supervised wiring. This module mounts in a single gang box. SD500-ARM A relay module that provides one relay with two Form C contacts rated at 2.OA @ 30 VDC or 0.6A @ 120 VAC. The SD500-ARM can control a wide variety of normally open or normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. SD500-ANM A notification module that lets you add notification circuits wherever they are needed on an FACP SLC loop. The SD500-ANM provides supervised monitoring of wiring to load devices such as bells, horns, and strobes. You can supply power to this module near the signaling appliance to reduce wire gauge requirements or supply power from a main power supply and control it separately by the individual notification modules. The SD500-ANM supports Class B and Class A wiring and all 16 notification patterns available on the FACP. SD500-SDM A two-wire interface module that allows an FACP to interface with and monitor two-wire conventional devices. This means you can retrofit an existing building and use existing conventional devices, including two-wire smoke detectors and devices with dry contacts, such as pull stations and heat detectors. The SD500-SDM transmits the status condition (normal, open, or alarm) of one full zone of two-wire devices to the FACP. The SD500-SDM supports Class B and Class A wiring SD500-LED An LED driver module that connects to the SLC loop and is capable of driving 80 LEDs. IntelliKnight FACPs support up to 40 SD500-LEDs per SLC loop. Accessories SD500-PS/SD500-PSDA The SD500-PS is a single action pull station requiring only one motion to activate the station. The SD500-PSDA is a dual action pull station requiring two motions to activate the station. Both pull stations feature a rugged metal construction and mount in a single gang box. SD505-DTS-2 SD500-PS A remote test switch for use with the SD505-DUCTR that provides remote key operated test function and annunciation of detector alarm. SD505-6SB A 6" mounting base adds an audible output function to SD505- APS, SD505-AIS, and SD505-AHS. The SD505-6SB can be used as a single station, multi-station, or as a system sounder. SD505-6RB A 6" mounting base with one Form C relay contact. The SD505- 6RB lets you control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. Because this relay is addressable, the relay device can be located at any point on the SLC loop. SD505-61B A 6" mounting base with a built-in isolator for SD505-APS, SD505-AIS, and SD505- AHS detectors. When the 8D505-61B is connected to the SLC loop, a short, open, J or ground fault occurring on the SLC loop ¶ is detected as a trouble but all SLC ...- devices continue to operate. SD505-61B ' -- - fits under SD505-6AB detector base -- (included). SD505-61B Isolator Base SD500-LIM SD505-6AB A line isolator module that isolates a " A 6" mounting base is for use with SD505-APS, SD505-AIS, short circuit wiring fault on an SLC J f and SD505-AHS. loop. When a short occurs on the SLC loop, it is detected as a trouble but all SD505-4AB A 4" mounting base is for use with SD505-APS, SD505-AIS, of the SLC devices protected by a SD500-LIM will continue to operate. ç ---j J and SD505-AHS. SD500-LIM D SILENT This document is not intended to be used for installation purposes. We try to keep MADE IN AMERICA our product information up-to-date and accurate. We cannot cover all specific KNIGHT applications or anticipate all requirements. All specifications are subject to change PN 53624 Rev B2 without notice. For more information, contact Silent Knight 12 Clintonville Road, © 2010 Honeywell International Inc. by Honeywell Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com Before You Begin Installing TO AC Input 0 ------------------- 0 oute all low voltage wiring through an of these krioôkouts. 10 [i 0J 0 0 J Maintain 1/4 spacing between I batterjcaEiles and input wiring. battery cables from under aluminum housing. --------------------- All circuits, except batterycables and AC, are power limited. Maintain at least 1/4 spacing between power limited and non-power limited circuits. Separate high and low voltage circuits. Fire alarm power-limited circuits are installed using types FPL, FPLR, FPLP or permitted substitute cables, provided these power-limited cable i conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.35 mm) or by a nonconductive sleeve or nonconductive barrier from all other conductors. Figure 3-1 Wire Routing Example 151209 3-5 tssis Jnting S y Switch ut rogramm i ng orts Chas Mou r Nuts lntelliKnight 5820XL Installation Manual 3.5 Board Assembly Diagram On-board Annunciator To AC Figure 3-2 Model 5820XL Assembly Figure 3-2 shows the circuit boards, metal housing and annunciator that attach the 5820XL assembly to the cabinet. If you should need to remove the board assembly for repair, remove the four mounting nuts which hold the assembly in the cabinet. Then lift the entire assembly out of the cabinet. Do not attempt to remove the circuit boards from the metal bracket. 3-6 151209 Intel/Knight 5820XL Installation Manual 3.6 Calculating Current Draw and Standby Battery This section is for helping you determine the current draw and standby battery needs for your installation. 3.6.1 Current Draw Worksheet Requirements The following steps must be taken when determining 5820XL current draw and standby battery requirements. You will use the Current Draw Worksheet to determine current draw and standby battery requirements. Use Table 3-1 if installing SK SLC Devices and Table 3-2 if installing Hochiki SLC Devices. For the 5820XL, the worst case current draw is listed for the panel, addressable devices, and all SBUS expanders. Fill in the number of addressable devices and expanders that will be used in the system and compute the current draw requirements for alarm and standby. Record this information in the Current Draw Worksheet on Line A. Add up the current draw for all auxiliary devices and record in the table at Line B. Add up all notification appliance loads and record in the table at Line C. For notification appliances and auxiliary devices not mentioned in the manual, refer to the device manual for the current ratings. Make sure that the total alarm current you calculated, including current for the panel itself, does not exceed 6.0 A. This is the maximum alarm current for the 5820XL control panel. If the current is above 6.0 A you will need to use a notification power expander(s) such as the Silent Knight 5495 or the 5895XL intelligent power expander, to distribute the power loads so that the 5820XL or the power expanders do not exceed their power rating. Refer to the current draw worksheets provided with the 5495 or the 5895XL manuals so you do not exceed their power requirements. 6. Complete the remaining instructions in the appropriate Current Draw Worksheet for deter- mining battery size requirements. 3-6 151209 Before You Begin Installing 3.6.2 Current Draw Worksheet for SK SLC Devices Use Table 3-1 to determine current requirements during alarm/battery standby operation when SK SLC devices are installed. You can install up 99 SK detectors per loop (396 max per panel) and 99 SK modules per loop (396 max per panel). Copy this section if additional space is required. Table 3-1: Current Draw Worksheet for SK SLC Devices Device # of Devices Current per Device Standby Alarm Current Current For each device use this formula: This column A This column = Current per number of devices. Fire Panel (Current draw from battery) 1 Standby: 215 mA 215 mA Alarm: 385 mA 385 mA Addressable SLC Detectors SK-Photo (99 max/loop & 396 max! panel) Alarm: SK-Acclimate Standby/Alarm: 0.27 mA mA mA SK-Photo-T mA mA SK-Ion mA mA SK-Heat mA mA SK-Heat-HT mA mA SK-Beam (without integral test) SLC Standby! Alarm: 2mA Aux. Pwr Standby 2 mA mA Alarm: 8.5 mA mA SK-Beam-T 5(with integral test) SLC Standby! Alarm: 2 mA Aux. Pwr Standby: 2 mA mA Alarm: 8.5 mA mA SK-Duct6 SLC Standby! 0.27 mA mA mA Standby/Alarm: 0.3 mA mA mA SK-Heat-ROR mA mA 151209 3-7 lntelliKnight 5820XL Installation Manual Device # of Devices Current per Device Standby Current I Alarm Current Addressable SLC Modules SK-Control (99 max/loop & 396 max! panel)' SLC I Standby! 0.375mA mA I Alarm 0.375mA mA Aux Pwr I Standby! 1.7mA I mA Alarm: 7mA mA SK-Monitor Standby/Alarm: 0.375 mA mA mA SK-Minimon mA mA SK-Pull-SA mA mA SK-Pull-DA SK-Monitor-2 Standby/Alarm: 0.75 mA mA mA SK-MonlO Standby/Alarm: 3.5 mA mA mA SK-Relay-6 Standby/Alarm: 1.45 mA mA mA SK-Control-6 SLC Standby! 2.25 mA mA Alarm: 2.25 mA Aux Pwr Standby! 1.7 mA mA Alarm: 20 mA mA SK-Relay Standby/Alarm: 0.255 mA mA mA SK-Zone Aux Pwr Standby 12 mA mA Alarm 90 mA mA SLC Standby/ Alarm 0.27mA mA mA SK-Zone-6 Aux Pwr Standby 50 mA mA Alarm 270 mA mA SLC Standby/Alarm 2 mA mA mA SLC Accessories B501 BHT-2 Sounder Base (99 max/loop & 396 max! panel) Aux Pwr Alarm: Standby: 1 mA mA 15 mA mA SLC Alarm: 0.7 mA mA B224RB Relay Base Standby/Alarm: 0.5 mA mA mA RTS151/151 KEY Alarm: 7.5 mA mA PA100Z Alarm: 10 mA mA SLC Isolator Devices SK-Iso (Isolator Module) (100 max/loop &400 max! panel) Standby/Alarm: 0.45 mA mA mA B224B1 Isolator Base Standby/Alarm: 0.5 mA mA mA Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA 5860 Remote Fire Alarm Annunciator (8 max) Standby: 20 mA mA Alarm: 25 mA mA 5824 Serial/Parallel Printer Interface Module (2 max.) Standby/Alarm: 45 mA mA mA 5496 Intelligent Power Module (8 max.) Standby/Alarm: 10 mA 5895XL IntelliKnight Power Module Standby/Alarm: 10 mA mA mA 3-8 151209 A IV C E F G H I J Before You Begin Installing Device # of Devices Current per Device Standby Current Alarm Current 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 I/O Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220 mA (22 mA per relay) mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Notification Appliance Circuits Refer to device manual for current rating. Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter!, 1-5.2.5): H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. Total alarm All AH 4 Total ampere hours Add lines G and I. required AH 1. Total does not include isolator devices or accessory bases. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. SK-Beam-T draws a maximum of 500mA from Auxiliary power only when the test feature is used. this should be considered when determining auxiliary power capacity but not calculated into current requirements for day to day operation. The SK-Duct housing contains a vacant mount for a SK-Relay (sold separately). Current draw for the SK-Relay is calculated by increasing the SK-Relay row of the calculation sheet by one for each SK-Relay used with a SK-Duct. 151209 3-9 lntelliKnight 5820XL Installation Manual 3.6.3 Current Draw Worksheet for Hochiki SLC Devices Use Table 3-2 to determine current requirements during alarm/battery standby operation when Hochiki SLC devices are installed. You can install up 127 Hochiki devices per loop (508 max per panel). Copy this section if additional space is required. Table 3-2: Current Draw Worksheet for Hochiki SLC Devices Device # of Devices Current per Device Standby Current Alarm Current For each device use this formula: Thfs column X this column Current per number of devices. IntelliKnight 5820XL Fire Panel (Current draw from battery) 1 Standby: 215 mA 215 mA Alarm: 385 mA 385 mA Addressable SLC Devices 5D500-AIM (508 max.)' Standby/Alarm: 0.55 mA mA mA SD500-NUM mA mA SD500-PS SD500-ARM mA mA SD505-AHS mA mA SD505-AIS mA mA SD505-APS mA mA SDSOO-ANM (508 max.)' Aux. Pwr Standby: 8 mA mA Alarm: 60 mA mA ______ SLC Standby/ Alarm: .55 mA mA mA 5D500-SDM (508 max.)' SLC Standby/ Alarm: .55 mA mA mA Aux. Pwr Standby: 20 mA mA Alarm: 106 mA mA SDSOO-LED (100 max.)' Aux. Pwr Standby: 10 mA mA Alarm: 220 mA mA LED: 10 mA mA mA SLC Standby/ Alarm: 0.55 mA mA mA SLC Accessory Bases 5D505-6RB (508 max.) Standby/Alram: .082 mA mA mA 5D505-6SB (508 max.) Aux. Pwr Standby: 1 mA mA Alarm: 32 mA mA ________ SLC Standby/ Alarm: .082 mA mA mA 5D505-ADI-IR SD505-DUCTR (508 max.) Aux. Pwr _ Standby: 35 mA2 mA Alarm: 75 mA2 mA SLC Standby/ Alarm: .082 mA mA mA 5D505-DTS SD505-DTS-K (508 max.) None, included with SD505-ADHR worst case. 5D505-ADH SD505-DUCT (508 max.) None, included with detector current. SLC Isolator Devices (1024 max.) Standby/Alarm 0.092 mA mA mA SD505-61B (508 max.) Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA 5860 Remote Fire Alarm Annun. (8 max.) Standby: 20 mA mA Alarm: 25 mA mA 3-10 151209 Before You Begin Installing A H1. C D E F G H Device # of Devices Current per Device Standby Alarm Current Current 5824 Serial/Parallel Printer Intertace (2 max.) Standby/Alarm: 45 mA mA mA 5895XL IntelIiKnight Power Expander (8 max.) Standby/Alarm: 10 mA mA mA 5496 Intelligent Power Module Standby/Alarm: 10 mA mA mA 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 LED I/O Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220 mA (22 mA per relay) mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines E and F. Total standby All AH Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) H Multiply lines E and H. Total alarm All AH 4 Total ampere hours Add lines G and I. required AH Total does not include isolator devices or accessory bases. If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC or 240 VAC. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. 151209 3-11 lntelliKnight 5820XL Installation Manual 3.6.4 Maximum Battery Standby Load Table 3-3 shows the maximum battery standby loadfor the 5820XL based on 24 and 60 hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-1 for SK devices and Table 3 -2 for Hochiki devices) must be less than the number shown in Table 3 -3 for the battery size used and standby hours required * 33AH max battery size for FM (Factory Mutual) installations.. Table 3-3: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max Load for 60 hrs. Standby, 5 mins. Alarm 7 A 270 m 105 m 12 A 475 m 190 m 18 A 685 m 270 m 35 A 1.3A 540 m * Requiredfor NFPA 72 Auxiliary Protected Fire Alarm systems for Fire Alarm Service (City Box) and Remote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DACT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-3. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Use Table 3-3 to calculate the correct battery amperes/hour rating needed for your installation. 3.7 Installation Tasks Overview This section provides a chart listing tasks that need to be performed when installing the IntelliKnight 5820XL system. The chart is intended to be a handy way for you to make sure you have completed all necessary tasks. Unless noted, these tasks do not have to be performed in the order they are listed here. Important: Connect and address SLC devices before running JumpStart. Task See Sec. (for more info.) Main Panel Hardware Installation El Mount the control panel cabinet. 4.1 El Connect AC. 4.2 El Connect phone lines. 4.11 El Install 5815XL SLC expander modules (if needed). Required if more than 127 SLC devices are used. 4.6 El Install 5860 Remote Fire Alarm Annunciator modules if used. 4.5 El Install 5865 or LED Annunciator modules if used. 4.9 El Install 5880 LED I/O module if customized LED annunciation will be used. 4.8 El Install notification appliances. 4.13 El Install auxiliary power devices (if used). 4.13.5 El If using a printer, install the 5824 Serial/Parallel Printer Interface Module. 4.7 El Connect batteries (typically last step). 4.3 3-12 151209 5815XL Specifications System Capacity 5820XL FACP supports three 5815XL SLC Expanders. Each expander supports 99 SK detectors and 99 SK modules or 127 SD addressable devices. Operating Voltage 24 VDC Current Draw 55 mA minimum - 125mA max. Ambient Temp. 32°F to 120°F (0°C to 49°C) Mounting Inside 5820XL, 5895XL cabinet, or 5815RMK cabinet D SILENT KNIGHT by Honeywell Signaling Line Circuit Expander Add flexibility to IntelliKnight® applications with the 5815XL SLC Expander The Model 5815XL SLC Expander is a signaling line circuit controller for Silent Knight's lntelliKnight 5820XL FACP or 5820XL-EVS FACP with Emergency Voice System. It allows you to add 99 SK modules and 99 SK devices or 127 SD addressable devices to the lntelliKnight system. Add up to three 5815XLs to a system to achieve the maximum number of devices on the system. 5815XL signaling circuits have the same functionality as the SLC that is built into the lntelliKnight panel and support the same addressable devices as the main panel. The 5815XL connects to the panel via the RS 485 bus. Model 5815XL Signaling Line Circuit Expander The 5815XL expands the capabilities of the lntelliKnight fire control panel by allowing an additional 99 SK modules and 99 SK detectors or 127 SD addressable devices to be attached to the system. All functionality of the built-in SLC is provided with the 5815XL. Three 5815XLs can be added to an 5820XL or 5820XL-EVS lntelliKnight system for a total of 396 SK detectors and 396 SK modules or 508 SD addressable devices per system. Operation The 5815XL communicates with the lntelliKnight FACP via an RS 485 system bus. A green LED on the 5815XL board blinks to indicate good communication. If an addressable device on a 5815XL fails, the loop communicates the failure to the panel and continues to operate normally. Features Adds 99 5K modules and 99 SK detectors or 127 SD addressable devices to an 5820XL/EVS lntelliKnight system Three 5815XLs per system 5815XL SLCs have same functionality as the 5820XL/EVS, including Style 6 (Class A) configuration Communicates with the lntelliKnight panel via RS 485 system bus LED indicates good communication UL 864 listed, complies with NFPA 72 and 101 Communicates on most standard wiring systems (ideal for retrofits) FM approved; CSFM approved; MEA Model 5815XL SLC Expander Engineering Specifications The contractor shall provide a signaling circuit expander compatible with the lntelliKnight 5820XL fire control panel that allows 99 SK Modules and 99 SK Detectors or 127 SD addressable devices to be added to the system. The lntelliKnight panel shall support three expanders per system. The expanders shall provide signaling line circuits that have the same installation and functionality as built-in SLCs and shall communicate to the main panel via an RS 485 system bus. A green LED on the expander board shall blink to indicate communication with the main panel. 3 22 21 20 19 1 0000' Used In Class A configurations 5815XL SC- 5+ SC- S+ - + A B IN OUT TO 0000 1~ Y TOSLC Used for Loop SIIe6SLC Configuredon 5815XL Block Diagram SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT D to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350098 Rev G subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2013 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.siIentknight.com SILENT 5860 Remote Annunciator 130 KNIGHT by oneyweII Bring the power to control an lntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to twelve 5860s per 5820XL/EVS or 5808 system Install up to eight 5860s per 5700 system Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color 5860R: Red 5860: Gray 5860 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Compatibility The 5860 is compatible with the following FACP's: 5820XL Addressable Fire Control Panel 5820XL-EVS Fire Control Panel with Emergency Voice System 5808 Addressable Fire Control Panel 5700 Addressable Fire Control Panel PN 350224 Rev G © 2014 Honeywell International Inc 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP SBUS - iE-Z 01111111111: 5860 6860 5860 Up to 12 5860$ Per IFP-100/ECS or IFP-1000/ECS System Up to Eight 5860s Per 5700 System Compatible lntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting This document is not intended to be used for installation purposes. We try to DSILENT KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac©honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listees data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, lFP-1000: Control Units 058200P : Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor lntelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SDSOO-ANM : Addressable Notification Module SD500-LIM: Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB: Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVA)(-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NP SERIES — NP 12-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation. Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Oeration Due to the perfetly sealed construction and the recombination of gasseswithin the cellii the battery is almost / maintenance free. I / Terminals Layout Fastbn tab: 250 D 2SOOO4 .020 h J 5 .310 7.90 .250 6.3 .16 4.0 .031 0.8 H °2° 0.5 Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Nominal Capacity (Ah) NPI2-12 20hrt0 1.75o.3OC 12 lOhr to 1, 75po 20'C 11.1 5hri .7Cvc 10 1 hr to 1 (3C.. 2cHC 7.2 Voltage 12 Energy Dorisit u a a 104 Specic Erieqy 36 Int. Resistanco ro OHma j 16 Maximum discharge iA( 75 Short Circuit currunt (A( 360 Dimensions (mm) Length 151 98 - th Height 97.5 VVeiqht (Kg) . 4.05 Terminal D Layout 4 Teniunal Toque Nrii - e / a. SELF DISCHARGE CHARACTERISTICS 1( -C (SOT) 25 Th r U U 12 S 0 STORAGE WE MON11ISI 'N lC 104 NP SERIES -NP 12-12 Lead Calcium Grids The heavy duty lead calcium alloy gilds provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME 0Jk caaj;. • rnvoy Cns. D$ 150 PVV.l Pm...t2 17 I tsz 16 / °5 0 io NP DISCHARGE CHARACTERISTICS CURVES AT 25C (77°F) FOR WV FOR 56 601*10 O05 0IFOIy staIRd 6%VI) 6*11w-p in n BATTERY BATIEJIS : NP ATzstl7fll :j 5.0 0.G aS — ---- —1).------- - I-CURS SERVICE LIFE NP RANGE 1061160 CON00010a3 01003161) 56470005 2.276600 AWOI4TTEM00R.0TUREi21rc 51F TO ?2I I I ___ )11fr( YUASA Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15°C to 50°C Discharge — 20°C to 60°C Storage — 20°C to 50°C (fully charged battery) FLOAT CHARGE CHARACTERISTICS a -18 U O.250A - 2.2756P0 COGOTANT VOLTAGE CHEAGING N-) (nCA) CA AT 20C 69F) 140 IV) 120 035 063006066*16 - 100 CkIARVE 14 / - PORES 70*1% UISERERGE 03* GO 13.0 AnrU11so%GSCw-IRGC 40 5601 12.0 20 (1.05 - I I30 RGI10.CPERE - 040503166 TIME TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING 000UD05ONS OISCFIAROE CURRENT. 2.17C Anp. )F.V I.7V10Eti CI-EARETIIAG CURRENT 0.09C P030 CHARGINGVOLUME, 125% 00 DISCHARGEDCAPACITY (AIRES) AMFIENT TEMPEV.VTVJIIE 2760102600761072761 o2 10. EEEEEi 100% 60% 30% DIVOT 00*1 *101) 000)50*1 4I- ZOO 400 — IwO (RE (001 NIJMOERGP CYCLES Distributed by Yuasa Battery Inc. 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat. No. I NP 12-12 March09 www.boschsecurity.com 0 BOSCH Invented for life A 1.5 mm (16 AWG) red steel enclosure for control panels. UL Listed for Central Station Fire, Local Fire, and Remote Station Fire (N EPA 72). Region Certification USA UL AMCX: Central Station Alarm Units, NBSX: Household Burglar Alarm System (nits, J CSFM see our website FDNY- #6174UL864 9th Edition CoA NYC- 12-92-E, Vol. 12 12-92-E, Vol. 12 MEA NYC- 12-92-E, Vol. XV MEA D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set. Order number D8109 Accessories D101F Lock and Key Set Short-body lock set with two keys supplied. Uses the D102F (#203) replacement key. Order number D101F D102F Replacement Key Replacement key (*203) for the D101F lock set. Order number D102F caLL U1 R ALA < COMMUNCATOR FOR LTE NETWORKS a COMMERCIAL FIRE PRODUCT FEATURES . Certified for use on Verizon's LTE network for long, sunset- free installation. *- Meets UL 864 requirements for sole, primary or backup path communications. J Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LIE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. h•- 4r ifJ iiWUhj!jJ *-Jil[)J. '1/-..-1iWJ • 4 . y ;tnç I. .y•:::••'-- UL Listings Commercial Fire 864 Commercial Burglary Residential Control units & 365 • Police Station 985 • Household fire accessories for connected warning systems fire alarm systems burglar alarm 1023 • Household burglar units and systems alarm systems 1610 • central station burglar alarm units; Line security servcies For the most current product specifications and UL Listings visit www.Teiguard.com. CELLULAR ALARM COMMUNICATOR FOR. LIE NETWORKS 0 ®iWi JJI'I ti IS-i LJ ?J!!I1L J I,jiI; l f f_fl iiLti ;jl I :3 TifliIL Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-budding penetration Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. 0 @rrilhij I'11iIii i'J iLll 1 IL.) i1fluI) Telguard, a Division of Telular corporation . 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339• USA 800-229-2326, Option 5 • www.Teiguard.com • copyright ©2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosarajuteluIar.com DESIGN: Models *TG7LV001 *TG7LVA01 *TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING Listee s name model number, electrical rating and UL label APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc seT' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5D500-AIM EM D SILENT KNIGHT by Honeywell S0500-AIM & SD500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the SD500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 502 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9W x 4.9" H x 1" D (12.4W x 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA71 &NFPA72 UL 864 CSFM 7300-0559: 132 MEA429-92-E Vol. IX FM Approved for use with the 5820XL SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4'-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Ordering Information SD500.AIM Input Module Addressable input module with ivory cover plate. SD500-MIM Input Module Addressable mini input module. Compatible FACPs 5820XL 5820XL-EVS 5808 5700 SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev. F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. .www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0132 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model SD500-ARM Relay Module and 5D500-AIM, 5D500-MIM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models 5D500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell Addressable Photoelectric Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The InteIliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO Analog I Addressable Photoelectric Type Smoke Detector The SD505-PHOTO is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-PHOTO units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved Specifications Operating Voltage: 24-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA SD505-PHOTO Smoke Detector Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% non- condensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) SD505-61B SD505-6RB SD505-6SB P/N 350225 Rev G © 2015 Honeywell International Inc. Diameter = 3-15/16" 4 [I] Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL@ listed compatible with Silent Knight's IntelIiKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The 5D505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 4 Diameter = 5-15/16' Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to keep our KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7272-0559:0178 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Model 5D505-PHOTO analog, photoelectric smoke detector for use with Model 5D505-6AB base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 17.0-39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as an analog photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0410:0204 10-22-15 gt .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SD500-PS and SD500-PSDA Addressable Pull-Station IntelIiKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby current: .55mA Alarm Current: .55mA SD500-PS Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB DSILENT KNIGHT A Mounting to Single Gang Electrical Box Wiring II I SD500-PS and SD500-PSDA Addressable Pull-Station 21 Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP 0 Awl 0 1 it nw.pac 0FZF5LC. CFC-.P$LC- 0 co Mounting to Options Surface Mount Box j SD500-PSDA I Lr1 Installing SD500LK !IetrII must ht Dimensions tkI1-vrI DSILENT KNIGHT t. A Ith CWWM 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2003 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0136 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model PS-SKSA and 5D500-PS fire alarm pull boxes. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *updated 08-29-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT 5499 Distributed KNIGHT Power Module 0 by Honeywell The NAC expander that packs quite a combination punch, a whopping nine amps and built-in synchronization for appliances The 5499 Distributed Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 9 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® - what you need to drive power-hungry components like ADA notification appliances. The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5499. Call Silent Knight today for more information at 1-800-328-0103. Description The 5499 is a 9 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls that have 9-32 VDC outputs, such as the Silent Knight Model 5208 Fire Control/Communicator. The 5499 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5499 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 9 amps of notification power Built-in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A (Style Z) or 4 Class B (Style Y), or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B (Style B) or 2 Class A (Style D) Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Stand alone operation. Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in Connection to Local Fire Control Firepower 5499 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5499. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the Firepower 5499, which provides supervision between the 5499 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5499 signal circuits using the 4.7kw end-of-line resistors provided. Since the 5499 draws very little power from the control, it is possible to connect one Firepower 5499 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. 5499 Supervision The 5499 supervises a variety of functions including: Low AC power. Low battery condition. Earth ground fault. Auxiliary output power limit condition. EOL supervision trouble or power limited condition at an output. When a trouble condition occurs, Firepower 5499 creates a trouble condition on the host control signal circuits to which it is connected. Firepower 5499 still maintains the ability to be activated by the host control. In addition, the 5499 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Model 5499 Distributed Power Module Model 5499 Block Diagram Signal Circuit Output Signal I Signal I Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input ________ Module 5499 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Electrical Specifications Mechanical Specifications Ordering Information AC Input: 120 VAC at 3.OA Dimensions: 12.25" W X 16" H X 3" D 5499 Distributed Power Module Output: 24 VDC at 9 A 30.88 cm W x 40.64 cm H x 7.62 D cm Accessories: Current Operating Temp: SK-scK Seismic Compliance Kit Standby: 75 mA 32° to 120° F (0° to 49° C) Alarm: 205 mA Humidity: 93% non-condensing max. Auxiliary Power Circuit: I Notification Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B) Amps Per Output: 3.0 (9.0 amps total) Notification Circuit Output: 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kQ EOL resistor required on each Class B circuit No. of Inputs: 2 Input Configuration: 2 Class B (Style Y) or 2 Class A (Style Z) Input Voltage Range: 9 - 32 VDC Battery charging Capacity: 35.0 AH Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux Trouble: Yellow Output troubles (1-4): Yellow Installation Surface mount Approvals NFPA72 UL Listed CSFM 7300-0559: 123 MEA 429-92-E Vol. XII OSHPD (CA) OSP-0065-10 (see accessories) DSILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or an:icipate all requirements. All specifications are FORM# 350396 Rev F subject to change without notice. For more information, contact Silent © 2013 Honeywell International Inc by Honeywell Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or (203) 484-7161, Fax: (203) 484-7118. For Techinical Support, Please call 800-446-6444. www.silentknight.com Terminal # Description Ratings TBI 1 AC (black—hot") 120 VAC 60 Hz, 3A 2 Earth Ground 3 AC (white—neutral") TB2 1 Auxiliary Power(-) 27.4 VDC 3.0 amps 2 Auxiliary Power (+) 3 Notification 4 Output (-) 27.4 VDC 3.0 amps 4 Notification 4 Output (+) 5 Notification 3 Output (-) 27.4 VDC 3.0 amps 6 Notification 3 Output (+) 7 Notification 2 Output (-) 27.4 VDC 3.0 amps 8 Notification 2 Output (+) 9 Notification 1 Output (-) 27.4 VDC 3.0 amps 10 Notification I Output (+) 11 Normally Closed contact 2.5 A @ 250 VAC or 2.5 A @ 30 VDC 12 Common 13 Normally Open contact 14 Input 9-3OVDC 15 Input 2(-) 16 Input 2(+) 17 Input 1 9-3OVDC 18 Input 1 (-) 19 Input 1 (+) Although each output is rated for 3 amps, the total current draw from the 4 outputs and the auxiliary power must not exceed 9 amps. System Overview Section 3 System Overview Each output circuit is rated at 3 amps. DO NOT OVERLOAD. Overloading a circuit will cause it to shut down (power limit). The circuit will automatically reset once you remove the overload condition. 3.1 Terminal Descriptions and Electrical Ratings 151253 3 System Overview 3.3 Notification Appliance Circuit Terminals Terminals 3 through 10 are the notification appliance circuit output terminals. Each of the four circuits are rated at 3 amps, although you can only draw a total of 9 amps from the 5499. The 5499 outputs are short-circuit protected (power limited) according to UL 864 standards. Overcurrent indicators are yellow LEDs. The output voltage can vary depending on the load and input voltage. The four power-limited NAC outputs can be configured as follows: Four Class B circuits Two Class A circuits One Class A and two Class B circuits Class B, ANSI temporal-coded circuits AMSECO synchronized outputs Faraday synchronized outputs Gentex synchronized outputs System Sensor synchronized outputs Wheelock synchronization outputs One or both 5499 signal inputs control the NAC outputs, depending on the specific configuration setup. Possible configurations for the 5499 are: For Option: These Inputs: Control These Outputs: As: 1 Input 1 All outputs Class B circuits Input 1 or Class B ANSI temporal- 2 Outputs l,2,3, and 4 Input 2 coded circuits Input I Outputs I and 2 Class B circuits Input 2 Outputs 3 and 4 Class B circuits Input 1 Output I Class B circuits Input 2 Outputs 2, 3, and 4 Class B circuits 5 Input I Outputs 1-2 and 3-4 Class A circuit pairs Input 1 Outputs 1 and 2 Class B ANSI temporal-coded 6 circuits Input 2 Outputs 3 and 4 Class B circuits Input 1 Outputs 1-2 Class A circuit pair Input 2 Outputs 3-4 Class A circuit pair Input I Outputs 1-2 Class A circuit pair 8 Input 2 Outputs 3 and 4 Class B circuits Input 1 (Strobe Class A or Class B g Control) All outputs Input 2 (Audio Control) Faraday Sync. Output Input 1 (Strobe Class A or Class B io Control) All outputs Input 2 (Audio Control) Gentex Sync. Output Input I (Strobe Class A or Class B 11 Control) All outputs Input 2 (Audio Control) System Sensor Sync. Output Input 1 (Strobe Class A or Class B 12 Control) All outputs Input 2 (Audio Control) Wheelock Sync. Output 151253 5 Installation 4.3 Current Requirements (Standby and Alarm) 4.3.1 Current Drawn From Host Panel Table 4-1 shows the 5499 current draw requirements from the main control panel when the panel's notification appliance circuit is in alarm. The current draw from the main panel when it is supervising the 5499 is the same current draw that would be present when the main panel supervises an ordinary notification appliance circuit. Table 4-1: Alarm Current Drawn From Main Control Panel Panel Voltage Current Alarm Current (for typical voltages) 12 VDC 6.5 mA drawn from main panel's notification 24 VDC One input circuit: 15 mA appliance circuits. Both input circuits: 30 mA 4.3.2 Current Drawn from Battery Batteries used with the 5499 must not exceed 35AH. (33AH max. for FM (Factory Mutual) Installations). Batteries larger than 7 AH will not fit into the 5499 cabinet and must be housed in the RBB Remote Battery Box. See Section 4.7 for battery installation. The following is the maximum current draw from the auxiliary power terminals for standby calculations. These currents assume 24 or 60 hours of standby time, followed by 5 minutes of maximum alarm current. 195 mA for 24 Hour Standby Current 39 mA for 60 Hours of Auxiliary Standby Current The above numbers were calculated assuming the use of 7 AH batteries at 100% of rated capacity. The total current of the 5499, plus all items powered from it, must not exceed 9 A when the panel is in alarm. Use Table 4-2 to ensure that the current does not exceed 9 A and, that the desired amount of standby is possible for the battery intended for use with the 5499. 151253 9 5499 Distributed Power Module Installation Manual Table 4-2: Battery Calculation Worksheet Device Number of Devices Current per Device Standby Current Alarm Current For each device use this formula: This column X This column = Current per number of devices. 5499 Distributed Power Module (Current draw from battery) Standby: 75 mA 75 mA Alarm: 205 mA 205 mA 5499 Current 75 mA 205 mA Auxiliary Devices Refer to device manual for current ratings. Alarm/Standby mA mA mA Alarm/Standby mA mA mA Alarm/Standby mA mA mA Alarm/Standby mA mA mA Auxiliary Device Current mA mA Notification appliances Refer to device manual for current ratings. Alarm: mA 0 mA mA Alarm: mA 0 mA mA Alarm: mA 0 mA mA Alarm: mA 0 mA mA Notification Appliance Current 0 mA mA Total current ratings of all devices in system (line A + line B + line C) mA mA Total current ratings converted to amperes (line D .001): A A Number of standby hours (24 or 60 for NFPA 72, Chapter 1 1-5.2.5). 24 Hrs. for NBC, section 3.2.7.8 H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. In accordance with NBC and LJLC. (For example, 5 minutes = .0833 hours.) H Multiply lines E and H. Total alarm AH AH Add lines G and I. Total standby and alarm AH AH Multiply line J by 1.20. (20% extra insurance to meet desired performance) Total ampere-hours required AH 10 151253 RI C L1 E F G H K Installation 4.4 Connecting the 5499 to a Control Panel Figure 4-2 shows the general layout of the 5499 PC board. This section also provides specific wiring details for accessories. AC Connection Terminals See Section 6 for LED Descriptions / Es.bhd or Enabled if Jumper on Pins 2 & 1,OlsabIed If Jumper on Pins I & - -. For UL Listed Notification Appliances Figure 4-2 The Model 5499 PC Board Layout Consult the installation manual for specific wiring information for the control panel being used. 151253 11 5499 Distributed Power Module Installation Manual 4.4.1 Common Trouble Relay The 5499 has a Form C trouble relay built into Terminals 11-13. The relay provides a normally open and a normally closed contact, both of which are rated at 2.5A. The trouble relay will deactivate under any trouble condition. A typical application of the trouble relay is to connect the 5499 normally closed (N.C.) contacts in series with the EOL supplied with the fire alarm control panel. This will cause a trouble on the fire alarm control panel when the 5499 opens its trouble contacts. Note: The N. C. contact is the contact that is closed when the 5499 has power and there are no trouble conditions. I 9 101 i 2 13 I 14 15 16 I 17 18 1 9j OUTI I Ic TR fBLEI2NPUTI I UIPUT IHI.111+ I C4IM SO A H C I A H C UL listed EOL I (supplied with fire panel) is .019 Model Must be connected to 20 5207 a power limited source Figure 4-3 Trouble Relay Connection Example 12 151253 5499 Distributed Power Module Installation Manual pass the added current load from notification appliances. L2_ I5AU*H* I I I UTIc ii RI NC COM NO 42 1: Regulated — + - I. + I - + L J Supervised Notification J,t---' ,— Class A notification Appliance Circuits outputs from FACP Power-Limited I-' I (Class 2) Class A In 0 out ut ,-. — /two separate wres / I 0 Icping twislfng single Yke tw wires Fi7a F11 JJ Incorrect For system supervision of terminals 15 and 18, do not use looped wire under the terminals. Break the wire run to provide supervision of connections. Figure 4-4 Class A Supervised Input/Output Connections 4.5.2 Class B Supervised Wiring Figure 4-5 shows how to wire for Class B input and output supervision. Use in/out wiring methods for proper supervision (Refer to the Appendix for notification appliances approved for use with the 5499.) Class B Output Notification Circuits Figure 4-5 shows four, 1.5 A devices wired as Class B. Place a 4.7k ohm EOL resistor (provided) at the end of each circuit to enable supervision when using all outputs as Class B notification appliance circuits. The 4.7k EOLs must be wired to the terminals whether or not you are using all output terminals. 14 151253 Instal/at/on Class B Supervised Input Circuits Figure 4-5 shows Class B supervised wiring from a fire alarm control panel to the 5499. Use an EOL resistor as shown to enable notification appliance circuit input supervision. Some panels use EOLs that have a different value from the 4.7k ohm EOL resistor used by the 5499. In this case, the EOL must be UL listed for the fire alarm control panel (not the 5499). O 1 2 3 4 6 7 8 I 9 O ii 12 13 14 13 16 7 1& 9 AUX hUh i Olfl'fl I OUT.. I RUT': TROW1L8 INPIJ'rX INPL 1 113. 051 NO COIl NO A U C 8 Regulated E. Supervised - + -... + - .•-• .L1. \ NACs Afl: 1):. f (")• Class BNAC Class B I output from FACP ,. .s 'b., ,•q if— Modi 7628 Model 7628 /1 4.7k EOL 4,7k EOL / EOL for the FACP) (must be UL listed + Figure 4-5 Class B Supervised Input/Output Connections 4.6 Ground Fault Detection Enable/Disable Jumper In some cases the ground fault detection feature on the 5499 may interfere with the ground fault detection feature of the main control panel in the system. To disable the ground fault detection feature on the 5499, place the jumper block on J1, across Pins 1 and 2 (see Figure 4-2). 151253 15 5499 Distributed Power Module Installation Manual 4.7 Battery Connection Use two 12 VDC, 7 AH gel cell batteries inside the 5499 cabinet. For batteries larger than 7 AH (not to exceed 35 AH) use the RBB Remote Battery Box. It is recommended that you replace the batteries every five years. The following steps and diagram explain how to connect the batteries. Connect the black wire from the Battery - terminal to the negative (-) side of Battery #2. Connect the jumper wire provided (PN 140694) from the positive (+) side of Bat- tery #2 to the negative side of Battery #1. Connect the red wire from the Battery + terminal to the positive (+) side of battery #1. Jumper (PN 140694) Model 6712 1 1 (Supervised) Battery #1 - Battery #2 Figure 4-6 Battery Connection 16 151253 DSILENT KNIGHT by Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203-484-7161 Fax: 203-484-7118 www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MNI0-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two I2VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Reced 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NP SERIES -NP7-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience'in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combinatiàn of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest Layout oxygen recombination technology to effectively control the neThtion of ga diiFibr?ial u / 4 ® Low Maintenance Operation Du5eto the pefectly sealed construction and the e recombination of gasses within the cell the battery is almosf maintenance free. I Ii I - Teçmunals Falon tab., 187 A Fstori tab! 251) D INCA = MM '° fl'hCf{= MM HH 7 TT .059 1.5a ri~lo D. 5 (4 Nominal Capacity (Ah) NP7-12 20hr to 1 7h5h5 hCiC . 7 1 Ohrto 1 75vpc 20C 6.4 5hr to 1.7Ci';hc HHC 5.9 1 hrtc .60vp 20C 4.2 Vcitg 12 Energy Do: ity: L 91 Specific Enerc0 H 32 Int. Resistancs in Ohms 25 MasimLJrn dischsrge Al 40/75 Short Circuit current (A) 210 Dimensions (mm) Length 151 Width .- 65 Height ovEuh 97.5 - Wright (Kq C 2.65 Term:na - ND Lsciut 4 .Terrsrr:.l 10005. NIuI - NP SERIES — NP7-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. ,CYCLIC RECHARGE REGIME IT— is It NP DISCHARGE CHARACTERISTICS CURVES AT 25°C (77°F) FOR I2V FOR NOIS C 01v02 cpocIl5 ll02 eE SD50y 0 All BATTERY BATTERY - - NI' AT 25CC (flY) 120 MINUTES HOURS DISC4flHGE TIME FLOAT SERVICE LIFE NP RANGE TESTEIG C srnoNasrloAllss VOLT#CE ZGISEPC AMBIENT S MPEHATIJRE OS'S (MT TO )'T'F( 100 l2 J 55 LIFE YEARS) Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge - 15°C to 50°C Discharge - 20°C to 60°C Storage - 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS 17~ I 0 60 : L is STORAGE TIME (MONThAl FLOAT CHARGE CHARACTERISTICS o"N EDSITA. 1.1 IS27SVFC CONSTANT VOLTAGE CHARGING AT 20C (05(7 IA M ISO 0-RN çVOlUOC 11.0 I0Q c.00 - — 000 - 5112 GE VOLTAGE 4.0 85 100, 5-14 CR400155 T870 0401.010) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING C000fl1ONS DISCHARGE CURRENT 0.17C HAp. (F.V I.7OCELL CHRISTINE CURRENTS SOC MR. CI-IRROINC VOLUME 125% 00 0I5C-IA11OHO 552051EV (A2114 AMBIENT TEIIPEHATUHU SOR( TO 25'C (SHY) TO 77'E( 100 . 0 100% 50% 30%CIPI 501) 000 OF 015ECR ROE SC 400 010 03 1300 410 11013 NUMOEROF CYCLES )11 r( YUASA Yuasa Battery Inc. 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat. No NP7-12 January 08 Distributed by Exceder Strobe, Horn Strobe, and Horn Notification Appliances IFITION Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pie-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TDO01017EN Effective October 2014 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 Ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover pr 11 Ak- L 1' T LLJ'. it Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance draw® 12/24VDC on a single appliance Easy to remember model numbers ® Patented Note: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range': All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI/OSHA RoHS 2 EATON www.eaton.com HN Series Technical Data TDO01017EN HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24VDCI24FWR 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current® at Anechoic 99 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 '0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 KS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range 16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VOC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per ULAnechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn H = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering (strobes only) HNC 16-33.0 0.084 0.044 0.022 KS = Horn Strobe AL = Alert Lettering (strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering (strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1: STRC = Strobe, Red, Ceiling Mount Table 4. Specification & Ordering information Example 2: HSR = Horn Strobe, Red, Wall Mount Sync w/ DSM , Example 3: HSW = Horn Strobe, White, Wall Mount - Wheelock Power 1V2% Mounting Example 4: ST'vV-AL = Strobe, White, Wall Mount, Alert Lettering Model roue ..enuele Supplies vu%.' jpluoris Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB® Strobes SIR 15/1575/30/75/95/110/135/185 X X UMB® ST\N 15/1575/30/75/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X UMB® STWC 15/30/60/75/95/115/150/177 X X UMB® Horn HNR .X X LIMBO HNW 4'' I x X UMB® HNRC ,. X X LIMBO Example: HSR HNWC JX X UMB® ® 12 VDC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base LL 100 Example: HSWC EATON www.eaton.com 3 Technical Data TDO01017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-nch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Powering Business Worldwide Eaton Cooper Notification 273 Branchport Ave. Long Branch, NJ 07740 CooperNotification.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. TDO01017EN October 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners, I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95,110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed :J\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I ~a5*129ACBLE Product Specification Issued: 2005 FIRE ALARM UNSHIELDED, RISER RATED -_ PART NUMBER: FPL1120 DESCRIPTION: 2/18 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Paramters: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.060" Number of Conductors 2 Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter 0.170" Approximate Cable Weight (lbs iKft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 201C 6.43 Ohms/KIt. nom. Capacitance Between Conductors @ I KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 °C to 60 'C Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D EF ZONE O 123456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 li 531825748Fx 6-531-257455l * 11 IL a7AIATTBLE Product Specification Issued: 2005 FIRE ALARM UNSHIELDED, RISER RATED PART NUMBER: FPL1I30 DESCRIPTION: 2/16 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 16 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.070" Number of Conductors 2 Nom. Lay Length 5.0" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter 0.180" Approximate Cable Weight (lbs JKft.) 30 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20 4.02 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 40 pFlft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 to 60 Insulation Colors Red and Black Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D EF ZONE O1 23456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 • I Product Specification Issued: 2005 FIRE ALARM JACKETED UNSHIELDED, RISER RATED - PART NUMBER: FPL1140 DESCRIPTION: 2/14 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable for Riser Applications. Construction Parameters-. Conductor 14 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.015" Insulated Conductor Diameter 0.094" Number of Conductors 2 Nom. Lay Length 5.5" Jacket Material PVC Jacket Thickness 0.025" Nom. Overall Cable Diameter 0.240" Approximate Cable Weight (Ibs./Kft.) 40 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20t 2.52 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 40 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 C to 60 C Insulation Colors Black and Red Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D EF ZONE 0123456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Jinan Pac Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Jinan Pac Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: Nov 19, 2005 I ..........................................iq ;. ti-Dtiict. Jrai. Ch,a.2CiO4 . .-1Vlt c IAOLE lTc -2574 -531..2746l S 51 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL [1 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1505:0100 Page 1 of 1 CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: JINAN PAC CABLE & WiRE COMPANY248 Avenida Victoria, Unit A, San Clemente, CA 92672 Contact: Christoper "Derek" McMullen (949) 531-8996 Email: derek.mcmullenlgmail.com DESIGN: Power Limited Fire-Protective Signaling Cable, Type FPL, FPLP and *FPLR Refer to listee's data sheet for additional detailed product description and operational considerations. Insulation: PVC, SRPVC with minimum average thickness of 6 mils, minimum at any point at 5 mils; PVC compound Apex 910 with minimum average thickness of 6 mils, minimum at any point at 5 mils, maximum average thickness at 14 mils. *PVC compound Teknor Apex 96-A025A-115 with mm. average thickness 6 mils, mm. at any point 5 mils. Shield (Optional): Aluminum/polyester tape. Core Wrap (Optional): Polyester tape, 2 mils thick max. Jacket: PVC compound Teknor Apex 4128, PVC Compound Apex 910, and *PVC Compound 90-A033A-1 0 INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Type FPL, FPLP or *FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. *Rev. 11-14-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I