HomeMy WebLinkAbout1890 RUTHERFORD RD; ; FA040038; Permit10/27/21, 10:20 AM FA040038 Permit Data
City of Carlsbad
Fire Alarm Permit
Permit No: FA040038
1890 RUTHERFORD
Job Address:
RD
Permit Type: FALARM
Parcel No: 2121203500
Lot #: 0
Status: ISSUED
Applied 4/22/2004
Approved: 4/28/2004
Reference No.: Issued: 4/28/2004
PC #: Inspector:
Project Title: ISIS PHARMACEUTICALS FIRE ALARM PLAN CHECK &
INSPECTIONS
Applicant: Owner:
PDG CARLSBAD 47&48 L P
4330 LA JOLLA VILLAGE DR #110
SAN DIEGO CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
90 90 0
1/1
fO967
FAo4003
FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS
ISIS-PHARMACEUTICALS
SUITE 100
1890 RUTHERFORD RD.,
CARLSBAD, CA.
FIRE ALARM SYSTEM
(a NOTIFIER®
GENERAL
An HVAC system supplies conditioned air to virtually every area
of a building. Smoke introduced into this air duct system is thus
distributed to the entire building. Smoke detectors for use in air
duct systems sense the presence of smoke in the duct.
The FSD-751 Pair duct smoke detector is a photoelectric detector,
combining this detection technology with an efficient housing
design that samples air passing through the duct, allowing detec-
tion of a developing hazardous condition. When sufficient smoke
is sensed, an alarm signal is initiated at the fire control panel
monitoring the detector, and appropriate action can be taken to
shut off fans and blowers and change over air handling sys-
tems, etc. This can isolate toxic smoke and fire gases or prevent
their distribution throughout the areas served by the duct system.
Two LEDs on each detector can be programmed by the system
control panel to provide a local alarm indication. A remote alarm
output is provided for use with auxiliary devices. The FSD-751 P
has remote test capability with the RTS451/RTS451 KEY Remote
Test Station.
Traditional panels support addresses of 0-99. The FlashScan®
protocol supports addresses of 0ā 159. Patented FlashScan®
is a new communication protocol developed by NOTIFIER Engi-
neering that greatly enhances the speed of communication be-
tween analog intelligent devices. Intelligent devices communi-
cate in a grouped fashion. If one of the devices within the group
has new information, the panel stops the group poll and concen-
trates on single points. The net effect is response speed greater
than five times that of earlier designs.
APPLICATIONS
Duct smoke detectors have specific limitations.
Duct smoke detectors are:
NOT substitute for open area smoke detectors
NOT substitute for early warning detection.
NOTa replacement for a building's regular fire detection sys-
tem.
Call NOTIFIER for a copy of System Sensor's application guide,
Proper Use of Smoke Detectors in Duct Applications, (A05-
1004-00).
INSTALLATION
Wiring: For signal wiring (the wiring between detectors or
from detectors to auxiliary devices), it is recommended that single
conductor wire be no smaller than 18 AWG (0.75 mm2). The duct
smoke detector terminals accommodate wire sizes up to 12 AWG
(3.25 mm2). Flexible conduit is recommended for the last foot
(30.48 cm) of conduit; solid conduit connections may be used if
desired.
Smoke detectors and alarm system control panels have specifi-
cations for Signaling Line Circuit (SLC) wiring. Consult the con-
trol panel specifications for wiring requirements before wiring
the detector loop. The FSD-751 PIFSD-751 RP detector is de-
signed for ease of wiring; the housing provides a terminal strip
with clamping plates.
LED Features: If programmed with the system control
panel, two LEDs on each duct smoke detector light to provide
June 5, 2001 DN-6821 ā¢ H-215
FSD-751 P and FSD-751 RP
Intelligent Photoelectric Duct
Smoke Detectors with FlashScan®
Section: Intelligent Addressable Devices
MEA
143-00-E
(FSD- 75 IP)
38900E Approved LISTED CS308 (FSD-751RP) (FSD-751PA, S1115 FSD-75IRPA) MARYLAND
U
California State Fire Marshal
State Fire Permit #2036 (FSD-751P)
.. Marshal Permit #2060 (FSD-751RP)
3240-0028:205
local visible indication. Remote LED annunciator capability is avail-
able as an option. Each duct smoke detector can only be wired to
one remote accessory.
NOTIFIER panels offer different feature sets across different
panel models. As a result, certain features of the FSD-751P/
FSD-751 RP may be available on some control panels, but not on
others. Possible features, if supported by the control panel are:
Panel controls the LED operation on sensor. Operational modes
are: RED blink, RED continuous, GREEN blink, GREEN continu-
ous, and OFF.
SPECIFICATIONS
FSD-751P
Operating voltage range: 15 to 32 VDC.
Standby current: 300 pA @24 VDC (one communication every
5 seconds with LED blink enabled).
Operating temperature range: 32° to 131°F (0° to 55°C).
Humidity range: 10% to 93% (non-condensing).
Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters!
mm.).
Dimensions: 14.375" (365.125 mm) wide x 5.500" (13.970 mm)
high x 2.750" (69.850 mm) deep.
Options: RTS-451, RTS-451 KEY, RA400Z. Separate auxiliary
power not required.
FSD-751 RP
Operating voltage range: 15 to 32 VDC (comm. line voltage)
and 24 VACNDC or 120!240 VAC auxiliary power* (separate
source). *NOTE: The FSD-751RP requires a separate auxil-
iary source.
Standby current: 300 pA @24 VDC (one communication every
5 seconds with LED blink enabled).
Auxiliary power current draw (@ 24 VDC): 26 mA (standby),
87 mA (alarm).
Options: RTS451, RTS451 KEY, RA400Z, APA451.
FlashScan® is a registered trademark of NOTIFIER.
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications
or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203) 484-7118 E. 4 ; I 3T" ri.]
PlO TI Fl E R° 12 Clintonville Road, Northford, Connecticut 06472 ENClNEEIIINC & MANUFACTVRIN
DN-6821 ā¢ 06/05/01 - Page 1 of 2
>- Ui
N.- 0 --j- Cz U, Iā
W < i-0 00 682 lwir3wmf
FSD-751 P
Detector
Terminals
COMMON TEST
~C4' 6
\ Field-Installed
/___\
\ JUMPER
LED RESET
RTS451/RTS451 KEY The RTS45IKEY
uperating temperature range: 32° to 131°F (0° to 55°C).'
Humidity range: 10% to 93% (non-condensing).
Duct air velocity: 500 to 4,000 feetlmin. (152.4 to 1219.2 meters!
mm.).
Dimensions: 14.375" (365.125mm) wide x 5.500(13.970mm)
high x 2.750° (69.850 mm) deep.
Relay contact ratings: 2 Form-C, DPDT, 10 A @250 VAC, 10 A
@ 30 VDC (resistive). Minimum switching current of 100 mA @
SVDC.
Programming specifications/requirements
for intelligent system control panels:
The number of devices that can have their LEDs programmed tc
illuminate is limited by the features of the panel and the individua
devices. The actual number of devices is determined by the
control panel and its ability to supply LED current. Refer to the
control panel installation manual for details.
INLET TUBE SELECTION
Outside Duct Width Inlet Tube*
Up to 2 feet (0.6096 m) ST-1.5
2 to 4 feet (0.6096 to 1.2192 m) ST-3
4 to 8 feet (1.2192 to 2.4384 m) ST-5
8 to 12 feet (2.4384 to 3.6576 m) ST-10
*NOTE: Inlet tube is required and must be purchased separately.
Order one inlet tube for each duct smoke detector ordered.
-113RODUCT LiNk IINFORMATION
Model Description
FSD-751P Duct detector housing with FlashScan® photoelec-
tric smoke detector.
FSD-751RP Duct detector housing with FlashScan® photoelec-
tric smoke detector, DPDT relay.
ST-1.5 Metal sampling tube, duct widths 1' to 2 (see table
at left for metric lengths).
ST-3 Metal sampling tube, duct widths 2' to 4'.
ST-5 Metal sampling tube, duct widths 4' to 8'.
ST-10 Metal sampling tube, duct widths 8' to 12'.
RA400Z Remote annunciator alarm LED.
RTS451 Remote test station. Mounts in single-gang box.
Includes red alarm LED and magnet test switch.
RTS45IKEY Key-activated remote test station.
F36-09-00 Replacement filters.
M02-04-00 Replacement test magnet.
S08-39-0I Replacement photo insect screen.
P48-55-00 Replacement end cap for plastic sampling tube.
P48-21 -00 Replacement end cap for metal sampling tube.
A5053FS Replacement photoelectric sensor board.
A5067 Replacement power board (without relay).
A5060 Replacement power board (with relay).
SAMPLE WIRING DIAGRAMS See product Installation Intruct ions
for wiring diagrams for the FSD-751 RP.
+
00
2nd Detector
in Loop 7
6821wir1.wmf
N
FSD.751P N....
using a U
CD
c 0 0
-
- 6821wir2.wnf
FSD-751P RA400Z
Detector
Terminals
( J -
Page 2 of 2 - DN-6821 06/05/01
COMMUNICATION
LINE
UL Listed
Control Panel
+ I
00 00
IJU%.,'.. II;ur IJeLe4.LU1
L Listed control panel
4 FSD-751P Duct
' Smoke Detector
with optional
RA400Z
FSD-751P Duct
Smoke Detector
with RTS451/
RTS451 KEY
NOTE: For RTS451,
Terminal 3 is not used.
RTS451 does not have
a Terminal 6.
For RTS45IKEY, Ter-
minals 3 and 6 are not
used.
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 3240-0028:205 Page 1 of 1
CATEGORY: Duct Smoke Detector Housing/Base
LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653
Contact: Lawrence Flood (203) 484-1200 Fax (203) 282-7309
DESIGN: Models FSD-751 P, -751 PL, -751 RP, and -751 RPL duct smoke detectors. Units consist of an
enclosure, electrical components, sampling and exhaust tubes, and listed photoelectric smoke
detector sensor. Refer to listee's data sheet for detailed product description and operational
considerations.
RATING: 15to32VDC
INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner
acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, electrical and air velocity rating and UL label.
APPROVAL: Listed as duct smoke detectors for use with separately listed compatible fire alarm control units.
*Models FSD-751 FL and -751 RPL are suitable for use i n ducts where air velocity varies
between 100 and 4000 fpm. *Models FSD-751P and -751RP are suitable for use in ducts
where air velocity varies between 500 and 4000 fpm. Refer to listee's Installation Instruction
Manual for details.
*Corrected 12-03-03
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: DECEMBER 3, 2003 Listing Expires June 30, 2004
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No.
CATEGORY:
LISTEE:
DESIGN:
INSTALLATION:
MARKING:
APPROVAL:
NOTE:
7300-1209:129 Page 1 of 1
Misc. Devices/Control Unit Accessories
System Sensor, 3825 Ohio Ave., St. Charles IL 60174
Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245
Models RTS451 and RT5451 KEY remote test switches, and Model RTC remote test station
kit. Refer to listee's data sheet for additional detailed product description and operational
considerations.
In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
Listee's name, model number and UL label.
Listed as accessory devices for use with separately listed compatible duct smoke detectors*.
Formerly 7300-0087:129
*Rev. 06-16-2003
This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test
J results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager