HomeMy WebLinkAbout1890 RUTHERFORD RD; ; FA040038; Permit10/27/21, 10:20 AM FA040038 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA040038 1890 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2121203500 Lot #: 0 Status: ISSUED Applied 4/22/2004 Approved: 4/28/2004 Reference No.: Issued: 4/28/2004 PC #: Inspector: Project Title: ISIS PHARMACEUTICALS FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: PDG CARLSBAD 47&48 L P 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 90 90 0 1/1 fO967 FAo4003 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ISIS-PHARMACEUTICALS SUITE 100 1890 RUTHERFORD RD., CARLSBAD, CA. FIRE ALARM SYSTEM (a NOTIFIER® GENERAL An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system is thus distributed to the entire building. Smoke detectors for use in air duct systems sense the presence of smoke in the duct. The FSD-751 Pair duct smoke detector is a photoelectric detector, combining this detection technology with an efficient housing design that samples air passing through the duct, allowing detec- tion of a developing hazardous condition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers and change over air handling sys- tems, etc. This can isolate toxic smoke and fire gases or prevent their distribution throughout the areas served by the duct system. Two LEDs on each detector can be programmed by the system control panel to provide a local alarm indication. A remote alarm output is provided for use with auxiliary devices. The FSD-751 P has remote test capability with the RTS451/RTS451 KEY Remote Test Station. Traditional panels support addresses of 0-99. The FlashScan® protocol supports addresses of 0ā€” 159. Patented FlashScan® is a new communication protocol developed by NOTIFIER Engi- neering that greatly enhances the speed of communication be- tween analog intelligent devices. Intelligent devices communi- cate in a grouped fashion. If one of the devices within the group has new information, the panel stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. APPLICATIONS Duct smoke detectors have specific limitations. Duct smoke detectors are: NOT substitute for open area smoke detectors NOT substitute for early warning detection. NOTa replacement for a building's regular fire detection sys- tem. Call NOTIFIER for a copy of System Sensor's application guide, Proper Use of Smoke Detectors in Duct Applications, (A05- 1004-00). INSTALLATION Wiring: For signal wiring (the wiring between detectors or from detectors to auxiliary devices), it is recommended that single conductor wire be no smaller than 18 AWG (0.75 mm2). The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.25 mm2). Flexible conduit is recommended for the last foot (30.48 cm) of conduit; solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have specifi- cations for Signaling Line Circuit (SLC) wiring. Consult the con- trol panel specifications for wiring requirements before wiring the detector loop. The FSD-751 PIFSD-751 RP detector is de- signed for ease of wiring; the housing provides a terminal strip with clamping plates. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide June 5, 2001 DN-6821 ā€¢ H-215 FSD-751 P and FSD-751 RP Intelligent Photoelectric Duct Smoke Detectors with FlashScan® Section: Intelligent Addressable Devices MEA 143-00-E (FSD- 75 IP) 38900E Approved LISTED CS308 (FSD-751RP) (FSD-751PA, S1115 FSD-75IRPA) MARYLAND U California State Fire Marshal State Fire Permit #2036 (FSD-751P) .. Marshal Permit #2060 (FSD-751RP) 3240-0028:205 local visible indication. Remote LED annunciator capability is avail- able as an option. Each duct smoke detector can only be wired to one remote accessory. NOTIFIER panels offer different feature sets across different panel models. As a result, certain features of the FSD-751P/ FSD-751 RP may be available on some control panels, but not on others. Possible features, if supported by the control panel are: Panel controls the LED operation on sensor. Operational modes are: RED blink, RED continuous, GREEN blink, GREEN continu- ous, and OFF. SPECIFICATIONS FSD-751P Operating voltage range: 15 to 32 VDC. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters! mm.). Dimensions: 14.375" (365.125 mm) wide x 5.500" (13.970 mm) high x 2.750" (69.850 mm) deep. Options: RTS-451, RTS-451 KEY, RA400Z. Separate auxiliary power not required. FSD-751 RP Operating voltage range: 15 to 32 VDC (comm. line voltage) and 24 VACNDC or 120!240 VAC auxiliary power* (separate source). *NOTE: The FSD-751RP requires a separate auxil- iary source. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Auxiliary power current draw (@ 24 VDC): 26 mA (standby), 87 mA (alarm). Options: RTS451, RTS451 KEY, RA400Z, APA451. FlashScan® is a registered trademark of NOTIFIER. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203) 484-7118 E. 4 ; I 3T" ri.] PlO TI Fl E R° 12 Clintonville Road, Northford, Connecticut 06472 ENClNEEIIINC & MANUFACTVRIN DN-6821 ā€¢ 06/05/01 - Page 1 of 2 >- Ui N.- 0 --j- Cz U, Iā€” W < i-0 00 682 lwir3wmf FSD-751 P Detector Terminals COMMON TEST ~C4' 6 \ Field-Installed /___\ \ JUMPER LED RESET RTS451/RTS451 KEY The RTS45IKEY uperating temperature range: 32° to 131°F (0° to 55°C).' Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feetlmin. (152.4 to 1219.2 meters! mm.). Dimensions: 14.375" (365.125mm) wide x 5.500(13.970mm) high x 2.750° (69.850 mm) deep. Relay contact ratings: 2 Form-C, DPDT, 10 A @250 VAC, 10 A @ 30 VDC (resistive). Minimum switching current of 100 mA @ SVDC. Programming specifications/requirements for intelligent system control panels: The number of devices that can have their LEDs programmed tc illuminate is limited by the features of the panel and the individua devices. The actual number of devices is determined by the control panel and its ability to supply LED current. Refer to the control panel installation manual for details. INLET TUBE SELECTION Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5 2 to 4 feet (0.6096 to 1.2192 m) ST-3 4 to 8 feet (1.2192 to 2.4384 m) ST-5 8 to 12 feet (2.4384 to 3.6576 m) ST-10 *NOTE: Inlet tube is required and must be purchased separately. Order one inlet tube for each duct smoke detector ordered. -113RODUCT LiNk IINFORMATION Model Description FSD-751P Duct detector housing with FlashScan® photoelec- tric smoke detector. FSD-751RP Duct detector housing with FlashScan® photoelec- tric smoke detector, DPDT relay. ST-1.5 Metal sampling tube, duct widths 1' to 2 (see table at left for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4'. ST-5 Metal sampling tube, duct widths 4' to 8'. ST-10 Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS451 Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS45IKEY Key-activated remote test station. F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. S08-39-0I Replacement photo insect screen. P48-55-00 Replacement end cap for plastic sampling tube. P48-21 -00 Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). SAMPLE WIRING DIAGRAMS See product Installation Intruct ions for wiring diagrams for the FSD-751 RP. + 00 2nd Detector in Loop 7 6821wir1.wmf N FSD.751P N.... using a U CD c 0 0 - - 6821wir2.wnf FSD-751P RA400Z Detector Terminals ( J - Page 2 of 2 - DN-6821 06/05/01 COMMUNICATION LINE UL Listed Control Panel + I 00 00 IJU%.,'.. II;ur IJeLe4.LU1 L Listed control panel 4 FSD-751P Duct ' Smoke Detector with optional RA400Z FSD-751P Duct Smoke Detector with RTS451/ RTS451 KEY NOTE: For RTS451, Terminal 3 is not used. RTS451 does not have a Terminal 6. For RTS45IKEY, Ter- minals 3 and 6 are not used. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0028:205 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Fax (203) 282-7309 DESIGN: Models FSD-751 P, -751 PL, -751 RP, and -751 RPL duct smoke detectors. Units consist of an enclosure, electrical components, sampling and exhaust tubes, and listed photoelectric smoke detector sensor. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15to32VDC INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical and air velocity rating and UL label. APPROVAL: Listed as duct smoke detectors for use with separately listed compatible fire alarm control units. *Models FSD-751 FL and -751 RPL are suitable for use i n ducts where air velocity varies between 100 and 4000 fpm. *Models FSD-751P and -751RP are suitable for use in ducts where air velocity varies between 500 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. *Corrected 12-03-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 3, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: 7300-1209:129 Page 1 of 1 Misc. Devices/Control Unit Accessories System Sensor, 3825 Ohio Ave., St. Charles IL 60174 Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 Models RTS451 and RT5451 KEY remote test switches, and Model RTC remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL label. Listed as accessory devices for use with separately listed compatible duct smoke detectors*. Formerly 7300-0087:129 *Rev. 06-16-2003 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test J results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager