HomeMy WebLinkAbout1896 RUTHERFORD RD; ; FS070008; Permit10/27/21, 10:22 AM FS070008 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS070008 1896 RUTHERFORD Job Address: RD Permit Type: FIXSYS Parcel No: 2121203000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 6/13/2007 Approved: 6/18/2007 Issued: 6/18/2007 Inspector: Project Title: ISIS PHARMACEUTICAL FIRE SUPPRESSION SYSTEM PLAN CHECK & INSPECTION Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: P DG CARLSBAD 46 LTD 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance($)j 124 0 124 J 0 1/1 Tso~-0009 ..1••S.. cosco Fire Protection San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16-577621 www.coscofi're.com Date: 6-13-07 PHARMACEUTICAL 1896 RUTHERFOIDIVE/ ROAD CARLSBAD, CA. 2008 LM JOB#10CD5046 nfl All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: H.VILLEGAS APPROVED SJJWITTED CARLSBAD'RTMENT Los Angeles 0 San Francisco • Orange 0 Fresno 0 San Diego • Seattle FM200 FIRE SUPPRESSION SYSTEM ISIS PHARMACEUTICAL 1896 Rutherford Road Carlsbad, CA 92008 , - fIIIL.L FIRE PROTECTION, INC. CALIFORNIA C-16, C-b 0 LIC. #577621 SAN DIEGO COUNTY OFFICE 10695 TREENA ST., STE. 105 SAN DIEGO, CA 92131 (858) 444-2000 (858) 444-2056 FAX JUNE 2007 CHEIIIETROI! FM-200 ® Gamma Series Systems Fire Systems GENERAL INFORMATION The Chemetron Fire Systems Gamma Series Systems are automatic suppression systems using the FM-200 chemi- cal agent and consisting of four basic components and their associated accessories. FM-200 Components Control Panels Detection and Alarm Devices Completer Kits Features The FM-200 components consist of agent containers, container supports (racks), and discharge nozzles. The control panel is the brains of the system and is used to monitor the detection and accessories. The detection, alarm devices, and accessories are the external devices that act as the eyes and voice of the system as they give audible or visual signals. The completer kits consist of warning signs, hoses, connection fittings, pressure gauges or solenoid valves, and the actuator required to operate the cylinder valve. The system and its components are agency tested for total flooding applications and should be used in accordance with the guidelines contained in National Fire Protection Association 2001. A total flooding application can be de- fined as injecting FM-200 into an enclosure or volume having the structural integrity to retain the agent during and after discharge. The design of such a system requires that the FM-200 chemical agent be discharged from its container within 10 seconds and be thoroughly mixed throughout the protected volume, reaching a minimum concentration level of 6.25%, but not exceeding 9% in normally occupied spaces. GAMMA SERIES SYSTEM EQUIPMENT DESCRIPTION The Gamma System permits higher discharge rates and is particularly adaptable to areas requiring larger quantities of FM-200. A description of the various equipment com- ponents unique to the Gamma System follows. Cylinder and Valve Assembly Gamma Series cylinders are available in four different capacities and are charged with FM-200 to a filling densi- ty up to 70 lb/ft' (1121 kg/m') of cylin- der volume. All cylinders are super- pressurized with dry nitrogen to a pressure of 360 psig (2482 kPa), at 70°F (21°C). Each cylinder is equipped with an identification nameplate indi- cating the quantity of FM-200. The standard cylinder assembly, hav- ing a rigid dip tube, is designed for mounting in a vertical position only. The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve. (L) 3/16 FLEXIBLE f MALE CONNECTOR CONNECTOR \ I r (M) BLEEDER VALVE ' PTEE / (J) PNEUMATIC ACTUATOR CYLINDER VALVE (I) CHECK (B) SPRING VALVE (0) 0-RING (A) PISTON (I) CHECK (C) ELASTOMER SEAT VALVE (G) SOLENOID PILOT VALVE PULL A LEVER PORT TLET ITTING MANUAL PORT CHECK VALVE PNEUMATIC B ACTUATOR (K) 3/1 6 PILOT 00 ' -%oä'. , FLEXIBLE o ONNECTOR STORAGE CYLINDER 0 4od 0 Y° RUPTURE DISC DIP TUBE" .(E) FILTER & (F) BALL CHECK Cylinder Valve - Standby Mode MALE CONNECTOR (VENTED) (e) SPRING (A) PISTON (F) BALL CHECK (G) SOLENOID PILOT VALVE ACTUATED PULL LEVER .0 0 00 0 Cylinder Valve - Actuated Mode © 2004 Chemetron Fire Systems, All rights reserved (4/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems. FM-200 is a registered trademark of Great Lakes Chemical Corporation. CHEmETRO TM FM-200 ® Gamma Series Systems Fire Systems PIPE BY INSTALLER (NOT SHOWN) BLEEDER VALVE, 2' NPT ADAPTER MALE CONNECTOR, BRANCH TEE, AND NIPPLE Id 3/16 X 20" LG FLEXIBLE CONNECTOR RADIAL 2' GROOVED NOZZLE COUPLING T ,_A' PNEUMATIC I - 2' - 90 ACTUATOR GROOVED ELBOW 3/16" X 28" LG FLEXIBLE CONNECTOR CYLINDER VALVE AND 0—RING - SOLENOID PILOT VALVE ''- MANUAL *7 PNEUMATIC ACTUATOR SYPHON TUBE ~RAIL 79 LIQUID LEVEL OPTIONAL LOCATOR SPRING NUT CYLINDER SPACER STRAP CYLINDER NAMEPLATE LOCK WASHER AND CAP SCREW Gamma Series FM-200 CylinderAssembly with Completer Kit, Mounting Bracket and Nozzle Fill Capacity Cylinder StockMinimum Maximum Number ____F_ lbskg - lb I kg 150 lb. 10480993 -------82 37.2 163 73.9 With LLl 1 10480994 250 lb. 10480982 --------- ' 138 62.6 274 124.3 With LLl 10480985 4001b. 10480983 ---------' 211 95.7 421 191.0 With LLl 10480986 550 lb. 10480984 -- ------- ' 282 127.9 500 226.8 With LLl 10480987 Cylinder: The welded seam steel cylinders are manufactured to the requirements of the Depart- ment of Transportation (DOT) for compressed gas and have internal neck threads for cylinder valve connection. ED Dip Tube: A threaded dip tube extends from the cyl- inder valve down to within approximately 1-1/2 in. (38 mm) of the bottom of the cylinder. Cylinder Valve: A pressure differential type cylinder valve having a forged brass body is attached to the cylinder neck and serves to control the flow of FM- 200 from the cylinder. The valve is secured to the cylinder by means of 4.5-12UN-2A screw threads and is sealed by a cylinder 0-ring. A synthetic rubber seat is attached to a steel seat retainer, which is screwed into the bottom of the valve. The seat re- tainer also supports the dip tube. The cylinder valve has six connections, as follows: J J Manual-Pneumatic Actuator Connection: This is a threaded connection housing a check valve and serves as the attachment point for the manual- pneumatic actuator. ID Pressure Gauge/Solenoid Pilot Valve Assembly Connection: This is a threaded connection housing a check valve and serves for the attachment of: Solenoid pilot valve assembly (with pressure gauge) for pilot cylinders. Pressure gauge assembly for all other system cyl- inders. Pneumatic Actuator Connection: This is a threaded connection housing a check valve located on top of the cylinder valve. It serves as an attachment point for the pneumatic actuators. ED Safety Disc Connection: Two frangible safety discs are located on opposite sides and serve to protect the cylinder against excessive internal pressure. The discs are designed to burst in a range of 850 psi to 1000 psi (5860 kPa to 6895 Kpa). ns Discharge Connection: This connection (2 in. nomi- nal pipe size) (51 mm) is in the form of an outlet fit- ting that threads into the valve body and is sealed with an 0-ring. The exposed end is grooved for at- tachment of grooved fittings (Victualic, etc.). The outlet fitting can be removed for replacement if necessary. COMPLETER KIT Either a primary or slave completer kit is required to complete the installation of each FM-200 cylinder. The components included in the primary and slave completer kits are detailed in the following chart. © 2004 Chemetron Fire Systems. All rights reserved (4/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems. FM-200 is a registered trademark of Great Lakes Chemical Corporation. C1EIETRO11 FM-200® Gamma Series Systems Fire Systems Description Completer Kits Primary 20480644 Slave 20480645 Quantity Quantity Solenoid valve 1 0 Solenoid valve w/Supervisory Pressure Switch 1* 0 Pneumatic actuator 1 1 Manual-pneumatic actuator 1 0 1/4' Bleeder valve 1 0 3/16' flex hose 20" long 1 0 3/16" flex hose 28" long 1 1 2" 900 Elbow, grooved 1 1 2" Coupling, grooved 1 1 2" Adapter nipple 1 1 Tee, 1/4" F x 1/4" F x 1/4" M 1 0 Tee, 1/4" FL x 1/4" FL x 1/4' MNPT 0 1 1/4" Male connector 1 0 Pressure gauge 0 1 Pressure gauge w/Supervisory Pressure Switch 0 1* Warning sign 1 0 Cylinder Nameplate 1 0 * Items are part of the Primary (S/N 20480714) and Slave (S/N 20480722) Completer Kits with Supervisory Pressure Switch If cylinders are used in a Main/Reserve system, order decals: Main Decal - S/N 50360753 Reserve Decal - S/N 50360752 Solenoid Pilot Valve Assembly The system utilizes a solenoid pilot valve assembly to pro- vide pilot pressure for actuation. The solenoid must be electrically supervised by a recognized fire suppression system control panel. The solenoid pilot valve assembly includes a pressure gauge and adapter with swivel nut, elbow, and 0-ring seal that is attached to the pressure gauge connection of the cylinder valve. Stock Description Number 20610259 Solenoid pilot valve assembly 120 V-60Hz/24VDC 20610260 Explosionproof Solenoid pilot valve assembly 24VDC 20610261 Solenoid pilot valve assembly with supervisory pressure switch 120V-6OHz/24VDC SINIVEL CONNECT( Top View Front View Solenoid Pilot Valve Assembly Manual-Pneumatic Actuator - S/N 10610729 This device is required for the manual actuation of a cylin- der and is attached to a check valve connection port. This is a dual purpose device, having an actuating piston con- nected to a pin to upset the fill check valve when pilot pressure is applied to the piston. With the check valve open, cylinder pressure is applied through the pilot con- nection to the piston of the pneumatic actuator, thereby opening the cylinder to discharge its contents. REBOOT PIN -5/8' PULL DOWN (41.3 rofl( 10 ACTUATE 1/4' (6.4 roro) APP ROE. FLARE (TIP) JPORT PORT "B" (OUTLET)! (INLET') / (-(/4" (31 6roro) L1.12. . I (103.2 roro( 5/8' (38.1 rn) (31.8roo) APPROX. ((5,9 -)APPROX Front View Side View Pneumatic Actuator - S/N 10630022 The pneumatic actuator has a pis- ton connected to a probe to upset 432I') the connection check valve T' NPT when pilot pressure is applied r CAP to the piston. With the check valve open, pressure above the t J J piston of the cylinder valve ,,- BODY is rapidly vented to atmo- (82.6 / mro) sphere, thereby causing SWIVEL the cylinder valve to open. NUT 24' LEADS (609.6 nvn) /2 NPT (13 rooT) CONDUIT ENTRY nf_q~ 3 1/16" (93.7roro) PRESSURE GAUGE © 2004 Chemetron Fire Systems, All rights reserved (4/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems, FM-200 is a registered trademark of Great Lakes Chemical Corporation. cKEmErRon Fire Systems FM-200 ® Gamma Series Systems Bleeder Valve - S/N 10610731 1 '3/4" A bleeder valve is used in the ._ (20 mm) pilot line to prevent accumula- tion of pressure due to acciden- tal leakage through a solenoid pilot valve assembly, which, if unvented, could cause a false (70mm) discharge of the system. L 1/4" NPT (6.35 mm) Discharge Connection Fittings - S/N 20710212 A 2 in. (50 mm) grooved elbow, nipple, and companion coupling and gasket are used to extend the discharge outlet fitting of the cylinder valve o the piping system. These fit- . LO NIPPLE I tings ease assembly and GROOVED END THREADED ONE END I accommodate some mi- 0 7 1/4" (18.4 cm) nor differences in align- - AND 2" GROOVED I ment. COUPLING GASKET I 2 GROOVED 90' ELBOW Flexible Connector Lengths of 3/16 in. (5 mm) flexible connectors are used to interconnect the cylinder valve devices. These hoses have a stainless steel wire braid cover and a Teflon liner, and are fitted at each end with a 1/4 in. swivel flare nut. 1/4" (6.4 mm) WIRE BRAID COVER -45 FLARE TYPE 304 STAINLESS SWIVEL NUT-BRASS \STEEL EXTRUDED TEFLON INN ER CORE LENGTH Stock Number Description 10260260 3/16 in. (5 mm) Connector 16 in. (40.6 cm) long 10260267 3/16 in. (5 mm) Connector 20 in. (50.8 cm) long 10260303 3/16 in. (5 mm) Connector 28 in. (71.1 cm) long Pressure Gauge Assembly In systems requiring more than one cylinder, a pressure gauge assembly is required for each cylinder other than the pilot cylinder as a means of visual surveillance of the pressure condition within the cylinder. - 3" - (72.6 mm) - 1-5/8" (41.3 mm) Pressure Gauge Stock Description Number 20240041 Pressure Gauge Assembly 20610262 Pressure Gauge Assembly w/supervisory pressure switch OPTIONAL EQUIPMENT Pressure Switch A pressure switch is used in the system to implement the shut down of power and various items of equipment, such as fans; and for annunciation and alarm purposes. 1/4(6.4 mm) N.P.T. PRESSURE 2-3/4" [APPROX. 3/8" (9 5 mm) CONNECTION (69 9mm) - FO PRESS RE SRRICR 6-1/2" MODEL 1-017-0089 PUSH PLUNGER IN 10 RESET (165.1 mm) 0 ®lJ® DWIINORMAL I- 4-5/8" POSITION (117.5 mm) 1NOPERATEO POSITION 02004 Chemetron Fire Systems, All rights reserved (4/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems, FM-200 is a registered trademark of Great Lakes Chemical Corporation. cIEmETRo! FM-200 ® Gamma Series Systems Fire Systems Stock Number Description 10170089 2 Pole Pressure Switch indoor use only 70170229 Explosionproof 2 Pole Pressure Switch 10170065 14 Pole Pressure Switch weatherproof Check Valve - S/N 70610499 A check valve is used between the cylinder valve dis- charge outlet flexible connection and the discharge mani- fold. The check valve prevents back flow from the mani- fold in the event that the system is discharged when one or more cylinders are discon- nected, such as for weighing or general servicing. A check valve is not required on single cylinder systems. 3 5/t6 C84. ,-w-,) CYLINDER RACK Single/Multiple Cylinders, Vertically Mounted 150,250 & 400 lb - S/N 20710229 550 lb - S/N 20710264 The cylinder rack, consisting of a rail, a strap, and miscella- neous hardware for interconnection, is shipped unassem- bled. The rail is provided with 1-1/8 in. (2.85 cm) slots on 2 in. (5.0 cm) centers for mounting bolts. Stock Number Nominal Cylinder Size Dimension A B_____ in cm in cm 10480993 150 lb. 28 71.1 16 40.6 10480982 250 lb. 42-3/8 107.6 26 66.0 10410983 4001b. 61-5/8 156.5 38-1/2 97.8 10480984 5501b. 46-3/8 117.8 33 83.8 Stock Number Empty Cylinder Weight Lb (Kg) Cylinder Assembly Dimensions Height - Diameter In cm in cm 10480993 177 (80) 343/8 87.3 16 40.6 10480982 213 (97) 483/4 123.8 16 40.6 10480983 279 (126) 68 172.7 16 40.6 10480984 347 (157) 52 3/4 i 134.0 i 22 55.9 5 9/16' (141 RAIL LENGTH CENTER LINE OF 150, 250 & DISCHARGE OUTLET 400 lb = 20' /f_ 550 lb = 26' ,-'] ANTI—RECOIL PLUG -18 1/4 (46.3 cm) '4, L Cylinder Rack NOZZLES Nozzles (8 port) are used to control the flow of FM-200 to insure it is discharged within 10 seconds and properly dis- tributed in the protected hazard. NOMINAL PIPE SIZE (no CARDOX A ORIFICE TYP8 PLACES 3600 Radial Nozzle NOMINAL PIPE SIZE ORIFICE TYP 8 PLACES 1800 Sidewall Nozzle © 2004 Chemetron Fire Systems. All rights reserved (4/2004). Chemetron Fire Systems and Cardox are registered trademarks of Chemetron Fire Systems. FM-200 is a registered trademark of Great Lakes Chemical Corporation. cHEmETRo! FM-200® Gamma Series Systems Fire Systems Stock Number Nominal Pipe Size Nozzle Height A Stainless Brass in mm 3600 Radial Nozzle 10371360 10371415 3/8in(lOmm) 2.031 51.6 10371361 10371416 1/2in(l3mm) 2.250 57.2 10371362 10371417 3/41n(l9mm) 2.688 68.3 10371363 1 10371418 lin(25mm) 2.875 73.0 10371364 10371419 1-1/4 in (32 mm) 3.250 82.6 10371365 10371420 1-1/2 in (38 mm) 3.625 92.1 10371366 10371421 2in(5lmm) 4.500 114.3 1800 Sidewall Nozzle 10371407 10371423 3/8in(lomm) 2.031 51.6 10371408 10371424 1/2in(l3mm) 2.250 57.2 10371409 10371425 3/4in(l9mm) 2.688 68.3 10371410 10371426 lin(25mm) 2.875 73.0 10371411 10371427 1-1/41n(32mm) 3.250 82.6 10371412 10371428 1-1/2 in (38 mm) 3.625 92.1 10371413 10371429 21n(5l mm) 4.500 114.3 PHYSICAL/CHEMICAL PROPERTIES FM-200 (CF3CHFCF3 - heptafluoropropane) is a compound that consists of carbon, fluorine and hydrogen. It is colorless, odorless, electrically non-conductive, and suppresses fire by interrupting the combustion process and affecting the available oxygen content in the area of the discharge. FM-200 is clean, efficient, environmentally acceptable, and leaves no residue, thus minimizing any downtime after a fire. If exposed to temperatures greater than 1300°F, toxic prod- ucts of decomposition (hydrogen fluoride) are formed. The system is designed to discharge in 10 seconds or less to mini- mize the amount of toxic byproduct formed during extin- guishment of flames. Most materials contained in areas protected by FM-200, such as aluminum, brass, rubber, plastics, steel, and electronic components, are unaffected when exposed to FM-200. FM-200 is stored as a liquid in steel containers and super- pressurized with nitrogen to 360 psig (2482 kPa) to increase its discharge flow characteristics. When discharged, FM-200 will vaporize at the discharge nozzles and effectively mix with the air throughout the protected area. SAFETY CONSIDERATIONS In accordance with NFPA Standard 2001 and the EPA Signifi- cant New Alternative Program (SNAP), personnel exposure to FM-200 total flooding system concentrations shall be limited to the following: - The discharge of FM-200 into a hazard may cause a reduction in visibility for a brief period. Any direct contact with the agent can cause frostbite. A cylinder containing FM-200 should be carefully handled. All anti-recoil devices must be in place at all times when the cylinder is not restrained. The FM-200 Material Safety Data Sheet (MSDS) should be read and understood prior to working with the agent. Time for Safe Human Exposure at Stated Concentrations for FM-200 FM-200 Human FM-200 Human Concentration Exposure Time Concentration Exposure Time %v/v ppm (Minutes) %v/v ppm (Minutes) 9.0 90,000 5.00 11.0 110,000 1.13 9.5 95,000 5.00 11.5 115,000 0.60 10.0 1 100,000 5.00 12.0 1 120,000 0.49 10.5 1 105,000 5.00 NOTES: Data derived from the EPA-approved and peer-reviewed PBPK model or its equivalent. Based on LOAEL of 10.5% in dogs. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. CHEETROfl TO Fire System A World of Protection 4801 Southwick Drive Third Floor Matteson, IL 60443 708/748-1503 • FAX 708/748-2847 email: info@chemetron.com © 2004 Chemetron Fire Systems. All rights reserved (4/2004). Chemetron Fire Systems and Caraox are registered trademarks of Chemetron Fire Systems. FM-200 is a registered trademark of Great Lakes Chemical Corporation. Technical Data Bulletin M1002- 30198 Micro 1002/1002E Special Hazard Control Panel The Micro 1002/1002E Control Panel is supplied with the following standard features: Two Class A or Class B supervised detection zones programmable for single zone or cross zone detection One Class A or Class B manual station input One Class A or Class B abort station input programmable to four different options Two Class B supervised solenoid outputs Supervisory input option Two Class A or Class B alarm outputs California Pre-discharge timer Auxiliary relay card option State Fire Marshal Battery volt I ammeter option \31 MEA (pwbiprn Description PENDING --, The Chemetron Fire Systems Micro 1002/1002E Control Panel has been designed as a compact control center for Special Hazard Fire Protection System applications. The microprocessor based unit is suitable to perform detection and control functions associated with the following: NFPA 12 High Pressure CO2 Systems NFPA 12A Halon 1 301 Systems NFPA 72 Local Signaling Systems NFPA 2001 Clean Agent Systems The Micro 1002/1002E features four power limited inputs that are Class A or Class B supervised: Two detection zones, suitable for smoke detectors, thermal detectors and normally open alarm initiating devices. The detection zones are programmable for single zone or cross zone detection. Inputs are also provided for Manual Station actuation and Programmable Abort Switch operation. Ordering Information Two Class A or B indicating Alarm Circuits and two Class B Releas ng Solenoid outputs are also provided. For single solenoid systems, the second release circuit is programmable to provide a dedbatad Supervi- sory Input for Trouble Only" indications. The Micro 1002/1002E is supplied premunted in a Nema 1 enclosure with a hinged door. It includes an integral 24 VDC standby battery system capable of pro- viding in excess of 90 hours of battery back-up service. Optioial modules available for the Micro 1002/ 1002E include: Volt / Amm?ter Module to monitor the battery volt- age aid the battery charging current. Zone Relay 3oard to provide an additional Alarm and Trouble contact as well as independent contacts that transer in conjunction with each of the Indicating Alarm outputs and Releasing outputs. Stock Number Description Size (Inches) Shipping Weight lbs (kgs) 70100702 Micro 1002 Control Panel, 120 VAC 16 x 14.5 x 5 16 (7.3) 70100744 Micro 1002E Control Panel, 230 VAC, 50 Hz 16 x 14.5 x 5 16 (7.3) 70100700 Volt I Ammeter Module 1 (.45) 70100699 Zone Relay Board 1 (.45) 70100320 Battery 12V, 7AH 5.94 x 3.7 x 2.56 6 (2.7) © 1998 Chemetron Fire Systems. All rights reserved (3/98). Chemelron Fire Systems is a registered trademark. cHEmETRon rM Fire Systems Technical Data Bulletin M1002. 30198 INITIATING DL'AUS CLASS A or 0 SUPERVISED POWER LOOTED FOR SNoUTS DETECTORS TUCRUAJ. DETECTORS AND NORMALLY OPEN CONTACT DEVICES 4.7K OTUTA IIOTICATINO APPLIANCE CIRCUITS CLASS A or B SUPERVISED 2400C POLMNZED DEVICES ONLY 4.70 OHM CLASS A or 8 SUPERVISED POWER LIMITED ABORT STATION MANUAL STATION CLASS Aor8 I ' I SUPERVISED POWER LIMITED RRHot 11 V Optional Amm,t.r Conn.otlan Bafti,i., Optional Voltmt.r Conoaction Distributed by The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment form. 4801 Southwick Drive, 3rd Floor C HE Ill ETR0fl Matteson, IL 60443 TM Fire Systems 708/748-1503 Fax 708/748-2847 0 1998 Chemetron Fire Systems. All rights reserved (3/98). Chemetron Fire Systems Is registered trademark. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0061:104 Page 1 of 1 CATEGORY: Control Units (Non High-Rise) LISTEE: Chemetron, 4801 Southwick Drive, 3d Floor, Matteson, IL 60443 Contact: Gary Kimble (708) 283-4447 *FA)( (708) 283-6500 DESIGN: Model MICRO-1001 (preaction/deluge); Model MICRO-1002 (release); and Model MICRO- 400 (conventional). Inherently power-limited; non-coded; local, auxiliary, remote station (protected premises), proprietary (protected premises) and central station service; sprinkler supervisory and releasing device service. Refer to listee's data sheet for system detailed product description and operational considerations. System components: 4XTM Transmitter Module 4XZM Relay Module 4XLM Interface Module 4XMM Meter Module DP-4X Dress Panel 4XARB-1 Main Board 4XARB-2 Main Boards 4XARB-4 Main Board INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control panels for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. Proprietary protected premises unit: the system shall be interconnected with Potter Model EFT-C electrically actuated transmitter (CSFM Listing No. 7330-0328:104). Central station protected permises unit: the system shall be connected to either of the following transmitters: Firelite Model NoTI-FIRE 91 1N91 IAC series with ADEMCO Model 685 (CSFM Listing No. 7165-0078:133) control unit, or separately listed compatible control unit. XLF: 7165-0028:161 *Rev. 06-04-2004 vt.....o This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CHEmETROn Fire Systems Technical Data Bulletin PESO 1012000 Photoelectric Smoke Detector The Photoelectric Smoke Detector is supplied with the following standard features: Stable operation under extreme environmental conditions Dual Bi-color LED status indication Low-Profile design - attractive, unobtrusive Conforms to U.L. Standard 268, latest edition Designed in accordance with NFPA Standard 72E FMRC approved Backward compatibility to preceding detector and base designs Description STATE-OF-THE-ART TECHNOLOGY The Chemetron Fire Systems Photoelectric Smoke Detector features 2 bi-colored LEDs. In standby the LEDs flash green once every second. If the detector sensitivity drifts outside the UL listed sensitivity window, the LEDs will flash red every 3 seconds. Using the latest in photoelectric and surface mount technology, this detector reacts positively to smoldering and flaming fires. SIMPLIFIED OPERATING PRECISION It utilizes a labyrinth-style nondirectional smoke chamber. An infrared LED is mounted on one side and a silicone photo diode receiver is mounted at an angle on the opposite side. In normal standby condition, the receiver senses little or no light from the LED. When smoke enters the chamber, smoke particles reflect light from the LED onto the receiver. The light received is converted into an electric signal; signals are measured and counted in a comparator. When two consecu- tive signals exceed the basic level within a specified period of time, the time delay circuit triggers the alarm signal. Both LEDs light continuously red during an alarm condition. The detector head is fitted with an Allen head locking pin to help eliminate unauthorized removal and discourage vandalism. ADDITIONAL FuNcrioNs OPTIONAL An optional relay base is available to permit the smoke de- tectorto activate additional devices such as remote visual and audible alarms, door closers, etc. The compact relay module fits into the detector junction box. Ordering Information ARCHITECT/ENGINEER SPECIFICATIONS Early warning smoke detector shall be Chemetron Fire Systems detector stock number (see ordering information). It shall be of the photoelectric type and shall operate on the light scatter principle. Detectors shall be of low-profile design and shall protrude from ceiling not more than 2 inches. Each detector shall be adequately protected against radio frequency interference and voltage transients. A labyrinth arrangement shall be used to protect the photo diode located in the smoke chamber from stray light pulses caused by camera flashes or other exterior high-energy light sources. Detector head shall be fitted with a locking pin that requires an "uncommon tool" to allow for removal from its base. The head shall incorporate dual pulsing bi-color green LEDs as an indication of power at the detector head and red when the detector is outside the UL window. The LED shall illuminate steadily to provide a positive indication when the detector is in the alarm condition. Wiring shall be accomplished by using screw terminals. The base shall be capable of being used with both photo- electric and ionization detector heads. An optional relay base shall permit detectors to activate additional devices such as remote alarms, door closers, etc. Stock Number Description Shipping Weight lbs (kg) 70100906 Photoelectric Detector head with 43 mA Standard Base .5 (.23) 70100907 Photoelectric Detector head with 43 mA Relay Base 1 (.45) 70100908 1 Photoelectric Detector head with 93 mA Base .5 (.23) 70100909 Photoelectric Detector head, 135• F fixed temperature with 43 mA Std. Base 1 (.45) 70100910 Photoelectric Detector head, 135• F fixed temperature with 43 mA Relay Base 1 (.45) CHEMETROn t 711 Fire Systems Technical Data Bulletin PESO 1012000 PHYSICAL CHARACTERISTICS PHOTOELECTRIC SMOKE DETECTOR HEAD AND BASE ASSEMBLED 04 HOLE LARGE BASE DIAMETER (5 HELPS ELIMINATE NEED FOR TRIM PLATES. BASE IS RUGGED, BUT CONFORMS TO SLIGHT SURFACE IRREGULARITIES. ELECTRICAL CHARACTERISTICS Listed Control Panel .ri + U.L. LISTING NO. 51383 F.M. APPROVAL IO5AI.AY CALIFORNIA STAll FIRE MARSHAL PENDING Concealed terminals with End or Line 6/32 screws and food' Resistor through wiring provide easy instal(tion. :) 4-1/ 3 I I I ' ,"Detector Wiring - 0 0 I I ° Supervised OOI-:? 6 I I 6 I r LF -- I I I (Values I ______ Renote Re5istor1 PHOTOELECTRIC DETECTOR CUT nayvary) L.E. __ ________ with OPTIONAL RELAY 6' BASE ASS?. ANNUNCIATOR OUTPUT _J When using annunciators a reset switch must be provided. Optional Relay Base for adding functions such us remote Indicators, door closers etc. Two Form 'C' relays rated at 1 amp at 125 VAC. Both contacts transfer when detector alarms. Compact relay module Fits into detector Junction box. DETECTORS MANUFACTURED AND APPROVALS/LISTINGS MAINTAINED BY HOCHIKI. I I Standby I Alarm I Weight I Description Voltage I Current I Current I Head and Base Assembly I Photoelectric Detector Assembly 15.0- 33.0 45 I microamps I 150 I milliamps I With Standard Base, 6.2 oz. I With Relay I Base, 8.6 oz. Distributed by The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in sel]ers sales contract or sales acknowledgment form. C HE 111 ETROfl 4801 Southwick Drive, 3rd Floor Matteson, IL 60443 TM 708/748-1503 email: info@chemetron.com Fire Systems Fax 708/748-2847 Web Site: www.chemetron.com 0 2000 Chemetron Fire Systems. All rights reserved (812000). Chemetron Fire Systems is a registered trademark. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0410:107 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Hochiki America, 7051 Village Dr., Suite 100, Buena Park, CA 90621 Contact: Bob Misiuk (714) 670-3251 Fax (714) 690-7890 DESIGN: Models SLG-12, SLG-24, SLG-24FH, SLG-24F, SLK-12, SLK-24F, SLK-24FH, SLK- 24F8, SLK-24FL, SLK-24FLB, SLK-835, SLK-835H, SLR-835, SLR-835W, SLR-835B- 2, SLR-835B-4, SLR-835B-2W, SLR-835B-4W, SLR-24, SLR-24H, SLR-24V, *SLR 24VN, SLR-835H, SLR-835HW, SLR-835BH-2, SLR-835BH-2W, SLR-835131-1-4, SLR- 835BH-4W photoelectric type smoke detectors. Unit with suffix -H or -FH employs a supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12 VDC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units when used in conjunction with listee's listed bases (CSFM Listing No. 7300- 0410:132). Models with supplemental heat sensor are not approved for use in lieu of required heat detectors. NOTE: Formerly 7257-0410:107 *Rev. 2-14-2003 IPI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CHEmETROn Fire Systems Technical Data Bulletin ISO 1012000 Ionization Smoke Detector The ionization Smoke Detector is supplied with the following standard features: Stable operation under extreme environmental conditions Dual Bi-color LED status indication Low-Profile design - attractive, unobtrusive Conforms to U.L. Standard 268, latest edition Designed in accordance with NFPA Standard 72E FMRC approved Backward compatibility to preceding detector and base designs Description STATE-OF-THE-ART TECHNOLOGY ARCHITECT/ENGINEER SPECIFICATIONS The Chemetron Fire Systems Ionization Smoke Detector features two bi-colored LEDs for status indication. In standby the LED's flash green once every second. When the detector senses smoke and goes into alarm, the LEDs latch on red. The detector is comprised of a patented dual chamber smoke sensing element utilizing advanced electronic circuitry. The sensing chamber is unique in that a single radioactive source ionizes both the reference and sample chambers. This provides for stable operation over a wide air flow range. SIMPLIFIED OPERATING PRECISION Advanced smoke chamber design is enhanced by the use of high quality components. Automated assembly and 100% functional testing assure uniform operation. Each detector contains an alarm LED that pulses in the standby mode when power is present. In an alarm condition, the LED illuminates steadily to pinpoint the location of the triggered detector. SIMPLIFIED TESTING Testing is easy and reliable. A built-in reed switch permits the detector to be test-activated by an external magnet. This simple magnet test simulates activation by smoke at a level between 4% and 6% obscuration. This magnet test is especially useful in environmentally unstable or clean areas. ADDITIONAL FUNCTIONS OPTIONAL An optional relay base is available to permit the smoke detector to activate additional devices such as remote visual and audible alarms, door closers, etc. The compact relay module fits into the detector junction box. Ordering Information Early warning smoke detector shall be Chemetron Fire Systems detector stock number (see ordering information). It shall operate on the ionization principle. The detector shall consist of a dual chamber smoke sensing element with sampling and reference chambers that use the same radioac- tive source. Detectors shall be of low-profile design and shall protrude from ceiling not more than 2 inches. Static shielding shall protect against the operation interference of electrical noise. The detector shall not be affected by pressure or humidity changes. Detector head shall be fitted with locking pin that requires an "uncommon tool" for removal from its base. The head shall incorporate dual pulsing green LEDs as an indication of power at the detector head. The dual LED shall illuminate steadily on red to provide a positive indication when the detector is in the alarm condition. Wiring shall be accom- plished by using screw terminals. Positive, convenient testing shall be provided by a built-in reed switch, permitting activation by an external magnet, simulating activation by smoke. The base shall be capable of being used with both ioniza- tion and photoelectric detector heads. An optional relay base shall permit detectors to activate additional devices such as remote alarms, door closers, etc. Stock Number Description Shipping Weight lbs (kg) 70100911 Ionization Detector head with 43 mA Standard Base .5 (.23) 70100912 Ionization Detector head with 43 mA Relay Base 1 (.45) 70100913 Ionization Detector head with 93 mA Base .5 (.23) U.L. LISTING NO. S1383 F.M. APPROV ID5A1.AY CALIFORNIA FIRE MARSHA (PENDING) HEAD & BASE CNEMETROn Fire Systems"' Technical Data Bulletin ISD 1012000 PHYSICAL CHARACTERISTICS IONIZATION SMOKE DETECTOR HEAD AND BASE ASSEMBLED R3/I6'(41 LARGE BASE DIAMETER (5 7J1 -. HELPS ELIMINATE NEED FOR - - TRIM PLATES. BASE IS RUGGED, BUT CONFORMS TO SLIGHT SURFACE IRREGULARI1ICS, ELECTRICAL CHARACTERISTICS End of Line Concealed terminals with Listed Control Panel Resistor .6/32' screws and feed- __________ _________ easy installation 7 0 0 to I 21 I 2 I through wiring provide Supervised 1 I I I 0 0 0 I 0 4 Detector Wiring o Remote ResistorI IIDNIZATION DETECTOR I LED. .-...,,,_,,, (volues G _____ may vary) I I I I with OPTIONAL RELAY -LI _i...I1 - LJ BASE ASSY. ANNUNC OUTPUT IATOR When using annunciators a reset switch must be provided, Optional Relay Bose for adding functions such as remote indicators, door closers etc. Two Form 'C' relays rated at 1 amp at 125 VAC. Both contacts transfer when detector otrms. Compact relay nodule fits Into detector junction box. eDETECTORS MANUFACTURED AND APPROVALS/LISTINGS MAINTAINED BY HOCHIKI. I I Standby I Alarm I Weight I Description Voltage Current Current Head and Base Assembly I Ionization Detector Assembly 15.0-33.0 I 40 I microamps I 150 I milliamps I With Standard Base, 6.2 oz. With Relay I Base, 8.6 oz. Distributed by The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment form. CHEETROfl TM Fire System 4801 Southwick Drive, 3rd Floor Matteson, IL 60443 708/748-1503 Fax 708/748-2847 email: lnfo@chemetron.com Web Site: www.chemetron.com 02000 Chemetron Fire Systems. All rights reserved (812000). Chemetron Fire Systems is a registered trademark. EM CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7271-0410:135 Page 1 of 1 CATEGORY: Ionization Smoke Detector LISTEE: Hochiki America, 7051 Village Dr., Suite 100, Buena Park, CA 90621-2268 *Contact: Bob Misiuk (714) 670-3251 FAX (714) 690-7890 DESIGN: Models SlH-24F and *SI,J..24 ionization type smoke detector. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as ionization smoke detectors when used in conjunction with listed bases (CSFM Listing No. 7300-0410:132) and separately listed compatible fire alarm control units. NOTE: Formerly 7256-0410:110 & 135 *Rev. 11-16-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager September 17, 2001 DN-6840 F-710 (a NOTIFIER® NBG-1 21.11 and NBG-1 2LRA Dual-Action Agent Release Stations Section: Releasing Panels GENERAL The NBG-12LR and NBG-12LRA are Agent Release Sta- tions designed for use with NOTIFIER Fire Alarm Control Panels with releasing capabilities and RP Series Releas- ing Systems. FEATURES Non-coded, dual action operation. Made with durable polycarbonate. Optional surface backbox. NBG-I2LRA includes: V Abort switch. i/ Power-on indication. V Released indication. V Manual release (dual-action). NBG-12LR includes: V Dual-action release only. APPLICATIONS The NBG-I2LRA and NBG-12LR are ideal for areas such as clean rooms and computer rooms where a chemical agent is used to extinguish a fire. PRODUCT LINE INFORMATION NBG-I2LRA Agent release station with abort switch, Release LED, Normal LED. NBG-12LR Dual-action agent release station. SBA-1O Surface backbox for NBG-I2LRA. SB-10 Surface backbox for NBG-12LR. California State Fire Marshal i 7150-0028:199 LISTED S692 Approved SYSTEM SYSTEM NORMAL ACTIVATED 0 0 • TO ABORT- HOLD IN Dual-Action NBG-I2LRA (shown activated) This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203) 484-7118 • 31"r.". cj N OTI Fl ER' 12 Clintonville Road, Northford, Connecticut 06472 ENGINEER116 & MANUFACTURIF DN-6840•09/17101 - Page lof 2 A B System Operated LED (Red) I. 10K 1/4W System Normal LED (Green) 10K 1/4W Dual-Action NBG-I2LR E 00 07 Normally Open Abort Switch - --i © NBG-I2LRA (rear view) Agent Release Pull Station Page 2 of 2 - DN-6840 • 09/17/01 E 6840sbba.wmf ------------ 24 VDC I N.OJ ------------- Release Relay WIRING N.O. Abort Switch TO 4 D ______ Abort 10K,1/4W Circuit E Resistors _ To (+)2 Manual h * Release (-) I r Circuit 4 I OK, 1/4W 6840wfr1.wmf Resistors *NOTE: Mount End-of-Line Resistor on the last unit. *Mount 4.7K ELR on the last unit when abort switch and manual release switch are connected to control panel circuits. Mount 47K resistor on last unit when abort switch and manual release switch are connected to monitor module or control module. Refer to control panel manual for the listed ELR. Refer to the following documents when connect- ing to the control panel: S-500/TC-2 (P/N 15019/15023); S-5000/TCM-2 (P/N 15583/ 15805); RP-1002 (P/N 15151); AFP-200 (P/N 15511), AFP-400 (P/N 50253). B A1 I DIMENSIONS, BACKBOXES I- 4-1/2" (11.43 cm)1 1 ° a a o F 4-1/8" (10.48 cm) 0 I 0 both a U 0- 8-3/16" are 5-1/2" (20.8) SBA-1O 1-3/8" SB-1O (13.97) deep (3.49) __ U cOj CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CI 06472-1653 Contact: Larry Flood (203) 484*7161 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-128, NBG-12LR,NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-1-0, NBG-I2LOB, NBG-12W, NBG-12LW, NBG-I2NC, NBG-12WP, NBG-12LWP, NBG- 12L, NBG-12LX, NBG-12LA, NBG-I2PS, NBG-12LSP, NBG-I2LPS, NBG-12LPSP, NBG- 12SP, NOT-BG12LX, and *NBG..I2J(SP fire alarm pull boxes. All units except Model NBG- 128 are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-I2LW, NBG-12W, NBG-I2LWP, NBG-12LAO, NBG-12L0, NBG- I2LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *Rev. 1-06-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation av criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 7, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Technical Data Bulletin .S 30198 C0036MEMOn Fire System Abort Station The Abort Station is supplied with the following standard features: Helps prevent accidental suppression system discharge Easy to distinguish from standard fire alarm stations Choice of Deadman or Maintained contact configuration Fits standard single gang electrical boxes UL listed L)escription The Chemetron Fire Systems Abort Station is a manually- activated, electric device designed to let the user suspend discharge of the fixed fire protection system. Noticeably different in appearance from conventional wall-mounted fire alarms, the station is activated by lifting the switchguard cover, which breaks the protective seal and allows the toggle switch to be pushed into the ON position. The faceplate is constructed of formed steel and painted red. For permanence, all operating instructions are in raised letters, stamped into the faceplate. For added clarity, the letters are silkscreened in a contrasting color. Instructions are arranged in an easy-to-read format. The station is available in Deadman and Maintained contact arrangements that accommodate a wide variety of fire alarms and agent-releasing control equipment. A back box is available for surface-mounted installations. ARCHITECT/ENGINEER SPECIFICATIONS The fire suppression system shall include an abort switch to help guard against accidental discharge of the suppres- sion agent. It shall be a Chemetron Fire Systems s:cck number (see ordering info-mation) that operates with a two- pole switch mounted to a steel plate. Operating instructions shall be in raised letters, stamped into the faceplate. The raised letters shall be si:kscreened in a contrasting color. To help prevent accicental operatior, the abort swi:ch shall be protected by a ed PhenoITM plastic cover. The switch cover shall have a seal that breaks when lifted to provide positive identification that the unit has been operated. To avoid confusion, :he unit shall appea distiictly different from a fire alarm manual staticn. Ordering Information Stock Number Description Shipping Weight lbs (kg) 20100144 Deadman Abort Station .5 (.23' 20100143 Maintained Contact Abort Station .5 (.23) 30100207 Back Box for Surface Mounting .5 (.23) 3¼" o e o Knockout For Ic" Conduit Connection C) Switch Opening V 'e• 6 Surface C Using Be SIN 3-01 ForK," I I Conduit '-III I -Z Connection II: I '0 I I ] Knockout I IC,) 110 End view Mounting Detail Using Box SIN 3-010-0207 CHEIRESTROn Fire System Technical Data Bulletin AS 30198 Dimensions and Mounting Details Is 3¼" Flush Mount (Commercial O Box Dictatet Installation) Electrical Switch Rating: Contact Configuration: Characteristics 1.00 amp at 28 VOC ' 14 çP —31 l5L42i I ' I Distributed by The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment form. CHEMETROn 4801 Southwick Drive, 3rd Floor TM Matteson, IL 60443 Fire System 708/748-1503 Fax 708/748-2847 © 1998 Chemetron Fire Systems. All rights reserved (3/98). Chemetron Fire Systems is a registered trademark. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0061:103 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Chemetron, 4801 Southwick Drive, 3rd Floor, Matteson, IL 60443 Contact: Gary Kimble (708) 283-4447 *FAX (708) 283-6500 DESIGN: Models 2-010-0139, -0140, -0141, -0142, -0144, -0145 electrical box station. Units are intended for use with separately listed compatible fire alarm control panels to providing maintained or momentary type releasing service, aborting services and transferring services respectively. Refer to listee's data sheet for additional detailed product description and operational considerations. Part Number Function Switch 2-010-0139 CO2 discharge Maintained 2-010-0140 CO2 discharge Momentary 2-010-0141 Halon discharge Maintained 2-010-0142 Halon Discharge Momentary 2-010-0144 Abort Momentary 2-010-0145 Transfer (main/reserve) Maintained RATING: 28VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature rating and FM label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units for releasing service. *Rev. 06-04-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or i recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: JUNE 8, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager 1 00 COOPER Wheelock Series MB Motor Bells Description The Wheelock Series MB Motor Belts provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higherdBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (Arnencan National Standard forAccessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). Features Approvals include: UL Standard 464, Factory Mutual (FM), Califor nia State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures 6" and 10" shell sizes in 12 or 24 VDC models Integral RFl suppression to minimize included noise on the NAC circuit Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Built-in trimplate makes semi-flush mounting simpler and less expensive Screw terminals permit fast in-out field wiring of #12 to 18 AWG wire Polarized for DC supervision of NAC circuits Operates on filtered or unfiltered DC The Series RSSP retrofit plates may be synchronized when • For combined audible (bell) and visual signaling, convenient retrofit installed with the Wheelock Series SM, DSM, Sync Modules plate assemblies are available with Multi-Candela or Single candela or the PS-24-8MC Power Supply with Wheelock patented sync strobes (Refer to Fire Alarm Products Catalog for Series RSSP protocol. Wheelock synchronized strobes offer an easy way Sync/Non-Sync Strobes specifications and technical information) to comply with ADA requirements concerning photo-sensitive epilepsy. Ordering Information Model Number Order Code Shell Size Input Voltage (VDC) Average RMS Current UL Max* dBA © 10 Ft. Mounting Options 1B-G6-12-R 3942 6" 12 0.060 0.090 92 0.040 D,E,J,K,N,O,P,R,S MB-G6-12-S 4221 6" 12 0.060 0.090 MB-G6-24-R 3941 6" 24 0.030 0.040 MB-G6-24-S 4222 6' 24 0.030 0.040 MB-G10-12-R 3944 10" 12 0.060 0.090 MB-G10-12-S 4223 10" 12 0.060 0.090 MB-G10-24-R 3943 10" 24 0.030 0.040 MB-GI0-24-S 1 4224 10" 1 24 1 0.030 NOTES: Typical dBAat 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. * RMS current ratings are per UL average RMS method. UL max current rating is O the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage APPROVED (33v for 24v units). For unfiltered FWR ratings, see installation instructions. E5946 151.92-E 7135-0786:113 Wiring Fig. I Bell Models + FROM TO NEXT PRECEDING APPLIANCE I __________ APPLIANCE } OR END-OF-LINE OR FACP RESISTOR (EOLR) rcnirecrs ana tngsneers The'alarm aJpliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built-in trimplate for semi-flush mounting to a standard 4" square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Model Number Order Code Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC UL Max* Mounting Options RSSP-24MCW-FR 9402 24 15/30/75/110 .041063/.109040 .060/.092/.165/.220 D,E,Z RSSP-241575W-FR 7793 24 15 (75 on-axis) .060 .090 D,E,Z RSSP-121575W-FR 1 7798 12 15 (75 on-axis) .152 .255 D,E,Z * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Fig. 2 Retrofit Strobe Plate Models (RSSP) AUDIBLE STROBE r+-i FROM PRECEDING - 1. NEXT APPlIANCe. OR APPLIANCE FACP + + OR ROLE FROM TO NEXT — - PRECEDING STROBE OR STROBE OR + + ED11l FACP Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. NAWMeism 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S1500 MB 06/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:113 Page 1 of 1 CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Conventional Detector Bases NS6 AND NS4 SERIES BASE NO Series Bases Alarm Current ID NS6-224 OR NS4-224 43mA (70rnA © 33.OV MAX) 118-5 NS6-220 OR NS4-220 93rnA (I36mA © 33.OV MAX) H13-3 NSO-221 OR NS4-221 46mA (77mA @ 33.OV MAX) -$8.4 N66-100 OR NS4-I00' ISOmA Q 15.0- 33.OV MAX l-IB-55 Requires e&en-,ai cunent )miling to 150mA madmun. HSC- (X)R RELAY BASE & HSC- 4R4WIRE BASE 2 Wire A.xiiii.ry Relay Bases Alarm Currant ID HSC-224R 43mA (58mA © 30.OV MAX) 118-73 HSC-220R 88nA (98mA Q 26.5V MAX) 118-72 HSC-221R 49mA (62mA Q 30.0V MAX) 118-71 4 Wire Base Alarm Current ID HSC-4R 43mA (58mA © 30.OV MAX) N/A HSC-41R12 47mA (75mA Q 1 8.0V MAX) N/A HSC- (X) L LATCHING LED BASE 2 Wire Latching I Alarm Current ID I I HSC-224L 35-42mA © 24V (54mA MAX) HB-62 IHSC-220L I 67-80mA © 24V (88.5mA (!g 26.5VDC MAX) I 118-64 I I I HSC-221L 37-45mA Q 24V (57mA MAX) HB-63 The NS6 and NS4 Series is designed specifically for use with HOCHIKI Conventional Models SlJ-24 Ionization Smoke Detector, SLR-24V Photoelectric Smoke Detector, SLR-24H Photoelectric with Heat Smoke Detector, SLR-835 Photoelectric Smoke Detector, SLR- 835H Photelectric Smoke Detector w/heat, or DCD-135/190 Fixed Temperature/Rate-of-Rise Heat Detector. The Base is an electronics free 6" base featuring a plastic tamper-lock lug. Each base is equipped with a resistor. Refer to the chart (left) for additional specifications. The NS4 base is a 4" version of the NS6 base. Models HSC-224R, HSC-220R and the HSC-221R are designed specifically for use with the HOCHIKI Conventional Models SIJ-24, SLR-24V, SLR-24H, SLR-835, SLR-835H or DCD-135/190. The HSC-(X)R series is a 6" base with two sets of Form "C" relay contacts. Models HSC-224R, HSC-220R and the HSC-221R are also approved for use with HOCHIKI previous Conventional Models SIH-24F, SLK-24F, SLK-24FH and the DFE 135/190. The HSC-4R is designed specifically for 24 volt 4 wire applications using HOCHIKI Conventional Models SIJ-24, SLR-24V, SLR-24H, SLR-835, SLR-835H or DCD-1 35/190. The 6' diameter base is current limited. Relay contact place a direct short occurs across the loop when the detector is actuated. Model HSC-4R is also approved for use with previous HOCHIKI Conventional Models SIH-2417, SLK-24F, SLK-24FH and the DFE 135/ 190. The HSC-4R12 is designed specifically for 12 volt 4 wire applications using HOCHIKI Conventional Models SLR-835, SLR-835H. The 6" diameter base is current limited. Relay contact place a direct short occurs across the loop when the detector is actuated. Model HSC-4R12 is also approved for use with previous HOCHIKI Conventional Models SLK-835, SLR-835, and SLR-835H. The HSC-L Base Series is designed specifically for use with the HOCHIKI Fixed Temperature Heat Detectors Models DFE-135/ 190. The HSC-L Series is a 6' base featuring a current limiting resistor, latching annunciator output and a latching circuit so the alarm LED will remain lit until the control panel has been reset. We try to keep our product information up-to-date and accurate. However, we cannot cover all specifications or anticipate all requirements. For additional information contact your local distributor or Hochiki America Corporation Hochiki America Corporation Find latest revision at www.hochikl.com 7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 Phone: 714/522-2246 Fax: 714/522-2268 TechnicalSupport800/845-6692ortechnicalsupportchochiki.com ________ F0014 042O54 Conventional Detector Bases NS4 AND NS6 SERIES BASE 2-WIRE OPERATION UL LISTED CONTROL PANEL PANEL POWER 'b SUPPLY am. T V NS4 SERIES NS6 SERIES Annunciation device must be current limited to 20 mA @1 24VDC Maximum. Not limiting current could result in damage to the detector or cause a no alarm condition. HSC-(x)R RELAY BASE 2-WIRE OPERATION LISTED END OF LINE DEVICE NOTE: - WIRING TERMINALS FOR THE NS4 AND NS6 ARE IDENTICAL BASES WITH THE 'W SUFFIX ARE WHITE IN COLOR ULLI CON P1 LISTED END OF LINE DEVICE PIGTAIL AUXILLIARY 'RN i CONTACTS TWO FORM "C" OPURI RELAYS SHOWN WITH POWER OFF. HSC-4R FOUR WIRE BASE 4-WIRE OPERATION INITIATINGH CIRCUIT LISTED END OF LINE DEVICE LISTED 1) OF LINE RELAY l-EOLR12 OR HA-EOLR.24 ULUSTEDI. POWER SUPPLY I2VDCOR24VDC HSC-4R OR HSC.4R12 HSC- (X) L LATCHING LED BASE 2-WIRE OPERATION COMPATIBLE UL LISTED ( CONTROL PANEL o PANEL Tail POWER Pig SUPPLY HSC-(X) L SERIES NS6 SERIES NEGATIVE oils r alit HI,H2 -TERMINAL oYEL PIGTAIL AUXILLIARY CONTACTS oORN ONE FORM "C LISTED END OP LINE DEVICE We by to keep our product infomiation up-to-date and accurate. However, we cannot cover all specifications or anticipate all requirements. For additional information contact your local distributor or HocMiki America Corporation. HoctkiAmirm Corporation Conventional Detector Bases Specsllcatims subject tochangewtihoitnotice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0410:132 . Page 1 of 2 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Hochiki America, *7051 Village Dr., Suite 100, Buena Park, CA 90621-2268 Contact: Bob Misiuk (714) 670-3251 Fax (714) 690-7890 DESIGN: Detector bases (2 and 4-wire). Unit is intended for use with a separately listed compatible detector head. Refer to listee's data sheet for detailed product description and operational considerations. Models listed below. HA-4W HA-4W1 HA-4WX HA-2 HA-SL HA-SR HA-SLR HA-RA2 HA-NRA2 HA-1-1 2R HA-2R HA-22R HA-1-2 HA-1-2A HA-L2R HA-1-22 HA-1-22A HA-1-22F HA-1-22R HA-1-225 HA-LA2 HA-LRA HA-LRA2 HA-LNA2 HA-LNRA2 HS-2 HS-21- HS-2D HS-21 HS-21L HS-21D HS-22 HS-22L HS-22D HS-100 HS-200D HS-220 HS-220L HS-220D HS-221 HS-221L HS-221D HS-221X HS-221XL HS-221XD HS-224 HS-224L HS-224D HS-225 HS-225L HS-225D HS-2RB HS-21RB HS-220RB HS-221RB HS-224RB HS-2RB4 HSB-2 HSB-2N HSB-12-1 HSB-12-1N HSB-12-4 HSB-12-4N HSB-21 HSB-21N HSB-100 HSB-200 HSB-200N HSB-220 HSB-220N HSB-221 HSB-22 IN HSB-221 S HSB-224 HSB-224N HSB-225 HSB-225N HSC-4R HSC-21 L HSC-220L HSC-220R HSC-221 L HSC-221 R HSC-224RA HSC-224L HSC-224R HSC-225L HSB-DCP-6 HSB-NSA-6 YBA-M2 YBA-M21 YBA-M22 YBA-M220 YBA-M221 YBA-M224 YBA-M225 YBA-M100 YBA-MAP YBA-R3 YBA-RU4 YBA-RL/4- I YBA-RU4-2 YBA-RL/4-RA YBC-RL/12 YBC-RLII2-1 YBC-R1112-2 YBC-RLI12-4 YBC-RLI4-RA YBC-RU2NC YBC-RL/2NBE YBJ-RL/2ND YBN-R/2NA YBN-NSA-4 NS4-100 NS4-220 NS4-221 NS4-224 NS6-100 NS6-220 NS6-221 NS6-224 Models may or may not come with suffix -W. *Con.eded 11-06-2001 Listing No. 7300-0410:132 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as bases for use with listee's separately listed compatible smoke and heat detectors. Refer to heat or smoke detector listings for compatibility. Models HA-2R, HA-SLR, HA-LRA2 and HSC Series w/ suffix R are also suitable for releasing device service. Model YBA-R3 is intended for use with thermostat detector only. NOTE: Formerly 7300-0410:100, 106, 115, 124, 125, 126, 130, 131 & 133 *Corrected 11-06-2001 ° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 4 recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 1 00 COOPER Wheelock Series NS Horn Strobes and Series NH Horns - % N / Series NH Series NS Description: The Series NS Horn Strobe Appliances are designed for indoor, wall and ceiling mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or the Wheelock patented Multi-Candela strobe with field selectable candela settings of 15/30/75/110cd for wall mount and 15/30175/95cd and 115/177cd for ceiling mount. These versatile Horn Strobe Appliances can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. The Wheelock patented 2-Wire Series NS Horn Strobes and Series NH Horns offer more features with lower current draw than competitors. MEA APPROVED E5846 151-92-E 7125-0785:142 S5391 Features: Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADAJNFPA/UFC/ANSI compliant Complies with OSHA 29, Part 1910.165 Wall mount model Field Selectable Candela Setting 15/30/75/110cd (24 VDC Multi-Candela models) or 1575cd in 12 or24VDC Ceiling mount model Field Selectable Candela Setting 15130/75195cd and 115/177cd (24 VDC Multi-Candela models) Selectable Continuous Horn or Temporal (Code 3) 2 Selectable dBA settings of 90 and 95 dBA in both tones Patented Universal Mounting Plate 12 and 24 VDC models with UL "Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Wall and Ceiling Mount Ceiling models with same look as Wheelock round ceiling strobes and speakers NH horn is selectable 12 or 24 VDC in I appliance The strobes can be synchronized using the Wheelock sync modules or power supplies with built in Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: AIrCAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" Is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (CD) NS-24MCW 24 16.0-33.0 15/30/75/110 NS-241575W 24 16.0-33.0 15(75onAxis) NS-121575W 12 8.0-17.5 15 (75 on Axis) NS-24MCC 24 16.0-33.0 15/30/75/95 NS-24MCCH 24 16.0-33.0 115/177 Table 2: dBA Ratings for Series NS/NH Horn Reverberant dBA Anechoic dBA ©1 Oft per UL464 ©loft Description Volume 12 24 12 24 VDC VDC VDC VDC Continuous High 83 87 89 95 Horn Low 1 76 81 84 90 Code 3 High 79 82 89 95 Horn Low 72 76 84 T —-90 Table 3: UL Max Current* Series NS/NH 24 VDC Audible Wall Mount Strobe Models Ceiling Mount Strobe Models NH-12/24 NS-241575W NS-24MCW NS-24MCC NS-24MCCH @24VDC 15!75cd 15cd 30cd 75cd llOcd 15cd 30cd 75cd 95cd 115cd 177cd High (95) dBA 24VDC 0.044 0.104 0.074 0.107 0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA 24VDC 0.018 0.096 0.066 0.101 0.177 0.232 0.071 0.114 0.201 0.261 0.306 0.429 Series NS/NH I2VDC Audible Wall Mount * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NH-12124 Aud/Strobe @12V NS-121575W High (89) dBA 12 VDC 0.021 0.220 Low (84) dBA I2VDC 0.012 0.210 (4'Mng Diagrams" NS/NH APPLIANCE FROM + + TO NEXT PRECEDING - -44-, - APPLIANCE APPLIANCE, SMIOSM, OR EO.LR PS42/24-8MP, PS-i 2/24-BCP OR FACP + - SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE SM + STROBE - STROBE Strobe A NAC Circuit NS +Audjbl D <EOLR Audible - Audibi NAC Circuit NOTE: NS/NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to Installation instruction (P83983, P83600 respectively). For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P63177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662 for PS-24-8MC. SPECIFICATION & ORDERING INFORMATION Model Number Order Code Strobe Candela Sync W/ SM, DSM or PS-24-81VIC 24 VDC 12 s/DC Mounting Options# Agency Approvals - UL - MEA CSFM - FM - BFP NS-24MCW-FR 9404 15/30/75/110 X X - B,D,E,F,GH,J,N,O,R,X X X X X X NS-24MCW-FW 9405 15/30/75/110 X X - B,DE,F,G,HJ,NO,R,X X X X X X NS-241575W-FR 7806 15(75onAxis) X X - B,D,E,F,GH,J,N,OR,X X X X X X NS-241575W-FW 7811 15(75onAxis) X X - B,D,E,F,G,HJ,N,O,R,X X X X X X NS-121575W-FR 7816 15(75onAxis) X - X B,D,E,FGH,J,N,O,R,X X X X X X NS-121575W-FW 7618 15(75onAxis) X - X BD,EF,G,H,J,NO,R,X X X X X X NH-1 2/24-R 7449 - X X X B,D,E,FG,H,J,N,O,R,X X X X X X NH-1 2/24-W 7500 - X X X B,D,E,FG,H,J,NO,R,X X X X X X NS-24MCC-FR 3754 15/30/75/95 X X - E X * X X * NS-24MCC-FW 3753 15/30/75/95 X X - E X * X X * NS-24MCCH-FR 3756 115/177 X X - E X * X X * NS-24MCCH-FW 3755 115/177 X X - E X * X X * NH-12/24R-R 3752 - X - X B,D,E,F,G,H,J,N,OR,X X * X X * NH-12/24R-W 3751 - X - X B,DE,F,G,H,JN,O,R,X X * X X * NS and NH Ceiling Mount Appliances will be available July 2006. *pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHItECtS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing- Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. Where ceiling mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/95 candela or 115/177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. smomwMaism 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com Member - WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS/NH 10106 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7 125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models NH-12/24, NH-12124R, and *ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-24110W; NS4-1215W, NS4- 121575W, NS4-2415W, NS4-241575W, NS4-2430W, NS4-2475W and NS4-2411OW, NS-24MCW, NS4-24MCW, NS-24MCC, NS-24MCCH, *ZNS..MCW *ZNS..MCC *zNs.. MCWH and *ZNS..MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, *ZNS..MCC and *ZNS MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) NS-24MCW, NS4-24MCW, *ZNS..MCW: Selectable 15cd, 30cd, 75cd, 110cd *Ns..24Mcc *ZNS.MCC: Selectable 15cd, 30cd, 75cd, 95cd *Ns..24MccH *ZNSMCCH: Selectable 115cd, 177cd *ZNSMC\(/I: Selectable 135cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *All units are for wall mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-1 2/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 13, 2006 Listing Expires June 30, 2007 Authorized By: KEN VOLLENWEIDER, Senior Deputy Program Manager Pyrom C he iii One Stanton Street Part No. 417881 4XZM ZONE RELAY MODULE CUT JUMPER FOR NOW I LATCHING (SILENCEABLE) USE DISABLE SWITCH TO RELAY OPERATION DISCONNECT THE RELAYS —1 NO - 2 NC RELAY #1 —3 C —4 NO - 5 NC RELAY #2 —6 C —7 NO - 8 NC RELAY #3 —9 C - 10 NO - 11 NC RELAY #4 - 12 C - 13 NO - 14 NC ALARM - 15 C - 16 NO - 17 NC TROUBLE - 18 C RELAY #1 THROUGH #4 WILL ACTIVATE WITH OUTPUT #1 THROUGH #4 AND REMAIN LATCHED UNLESS JUMPER LATCH IS CUT Description The 4XZM Zone Relay Module is an optional module with zone/function relays for use with the Pyro-Chem PCR-1 00 control systems. Listings for this module are under the control unit. The Zone Relay module provides Form-C general alarm and trouble contacts, plus four Form-C relays that acti- vate with each of the four output circuits. These relays can be silenced/non-silenced by jumper option. Technical Information Dry, Form-C contacts rated for: 2.0 amps © 30 VDC (resistive) 0.5 amps @ 30 VAC (resistive) Ordering Information Shipping Part Weight No. Description lb. (kg) 417881 4XZM Zone Relay Module 0.5 (0.23) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0061:104 Page 1 of 1 CATEGORY: Control Units (Non High-Rise) LISTEE: Chemetron, 4801 Southwick Drive, 3rd Floor, Matteson, IL 60443 Contact: Gary Kimble (708) 283-4447 *FAX (708) 283-6500 DESIGN: Model MICRO-1001 (preaction/deluge); Model MICRO-1002 (release); and Model MICRO- 400 (conventional). Inherently power-limited; non-coded; local, auxiliary, remote station (protected premises), proprietary (protected premises) and central station service; sprinkler supervisory and releasing device service. Refer to listee's data sheet for system detailed product description and operational considerations. System components: 4XTM Transmitter Module 4XZM Relay Module 4XLM Interface Module 4XMM Meter Module DP-4X Dress Panel 4XARB-1 Main Board 4XARB-2 Main Boards 4XARB-4 Main Board INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control panels for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturers Installation Manual for details. Proprietary protected premises Unit: the system shall be interconnected with Potter Model EFT-C electrically actuated transmitter (CSFM Listing No. 7330-0328:104). Central station protected permises unit: the system shall be connected to either of the following transmitters: Firelite Model NoTI-FIRE 91 1A/91 1AC series with ADEMCO Model 685 (CSFM Listing No. 7165-0078:133) control unit, or separately listed compatible control unit. XLF: 7165-0028:161 *Rev. 06-04-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager