Loading...
HomeMy WebLinkAbout1896 RUTHERFORD RD; ; AS060288; Permit10/27/21, 10:24 AM AS060288 Permit Data City of Carlsbad Sprinkler Permit 1896 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2121203000 Lot #: 0 Reference No.: Permit No: AS060288 Status: ISSUED Applied 11/29/2006 Approved: 12/5/2006 Issued: 12/5/2006 PC #: Inspector: Project Title: ISIS INSTRUMENT LAB TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: P D G CARLSBAD 46 LTD 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA r Fees ($) J Add'I Fees ($) Total ($) Balance ($) L 124 0 124 0 1/1 March 5, 2004 Sprinkler 10 a 1. PRODUCT NAME Viking CCCF Approved Standard Re- sponse Pendent Sprinkler Part Number 12727F8 Available since 2004. 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION Viking CCCF Approved Standard Re- sponse Sprinkler Part Number 12727 is a small thermosensitive spray sprinkler available with a 155 °F temperature rat- ing and chrome finish. The small frame and 5 mm glass bulb provide a pleasing appearance. During fire conditions, the heat-sensi- tive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler ori- fice strikes the sprinkler deflector, form- ing a uniform spray pattern to extinguish or control the fire. 4. TECHNICAL DATA APPROVALS Approved by the China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the chart on page 10 b. Spacing Requirements: Maximum spacing 15 ft. (4,6 m). Minimum spac- ing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65°F (-55 °C). Minimum Operating Pressure: 7 psi (48,3 kPa). Rated to 175 psi (1 207kPa)waterwork- ing pressure. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-051000 or Cop- per UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 AVAILABLE FINISH Chrome-Enloy5 (patents pending) ACCESSORIES Sprinkler Wrenches: Standard wrench: Part Number 10896W/B (available since 2000) or 05000CW/B (no longer available). Wrench for recessed Standard Re- sponse Sprinklers: Part Number 07398W** (available since 1990), or Part Number 12144W/B**, available since 2003. NOTE: Re- cessed pendent sprinklers with protective caps must use wrench 12144W/B. °A %" ratchet is required (not available from Vi- king). Refer to the "Sprinkler Accessories" section of the data book. 5. AVAILABILITY AND SERVICE Viking products are available through a network of domestic, Canadian, and international distributors. See the Viking Corp. Web site for your closest distribu- tor or contact The Viking Corporation. Viking technical data may be found on The Viking Corporation's Web site at http://www.vikingcorp.com. The Web site may include a more recent edition of this technical data page. Sprinkler 12727FB with a standard 1/8" (3,1 mm) surface-mounted escutcheon Ceiling Opening Size: 2-5/16' (59 mm) Minimum, 2-1/2" (64 mm) Maximum. 2-1/8- 2 1/8 (54 mm)- ............... (54 mm) mm) (51 2 1-1/2" (38 mrn) 17-3/4- um Minimum (44,5 mm) Minimum J_ Maximum Sprinkler 12727FB Sprinkler 12727FB installed with a Microfast® Model F-i Adjustable Escutcheon. Figure 1 Sprinkler 12727FB installed with a Micromatic® Model E-1 Recessed Escutcheon. Note: Units of measure in parentheses maybe approximations. New page 10 a-b, dated March 5, 2004. Refer to technical data Form No. F061303 page SRI-2 for general care, installation, and maintenance - information. Sprinkler 10 b March 5, 2004 CCCF APPROVED STANDARD RESPONSE j IIJI1G®- I II[.U'7If_ 't SPRINKLER (Part Number 12727FB) Approval Chart4 Temperature KEY Finish CCCF Approved Standard Response Pendent Sprinkler 12727FB AIX+- Escutcheon (if applicable) Maximum WWP _175_PSI Thread Size Nominal K-Factor Overall Length I Temperature classification Nominal Temp. Rating (Fusing Point) Maximum Ambient Ceiling Temperature' Bulb Color CCCF Approva12 NPT1BSPU I I S. metric5 Inch mm 1/2' 15 mm 5.6 8,1 2-3/16 I 56 Ordinary 155°F (68 °C) 100°F (38 °C) Red AiX Approved Escutcheons3 Approved Temperature Rating Approved Finish x - Standard surface-mounted escutcheons orthe Microfast® Model F-i Adjustable A - 155 °F(68 °C) 1 - Chrome-Enloy® Escutcheon, or recessed with the Micromatic® Model E-1 Recessed Escutch- eon Footnotes 1 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2Approved, China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered separately from sprinklers. Refer to Viking's current price schedule. This table shows the listings and approvals available at the time of printing. 5Metnc K-factorshown is for usewhen pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factor shown by 10.0. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). New page 10 a-b, dated March 5, 2004. Refer to technical data page SRI-2 for Form No. F_061303 general care, installation, and maintenance information. March 5, 2004 Sprinkler 10 a 1. PRODUCT NAME Viking CCCF Approved Standard Re- sponse Pendent Sprinkler Part Number 12727FB Available since 2004. 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcsvikingcorp.com 3. PRODUCT DESCRIPTION Viking CCCF Approved Standard Re- sponse Sprinkler Part Number 12727 is a small thermosensitive spray sprinkler available with a 155 °F temperature rat- ing and chrome finish. The small frame and 5 mm glass bulb provide a pleasing appearance. During fire conditions, the heat-sensi- tive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler ori- fice strikes the sprinkler deflector, form- ing a uniform spray pattern to extinguish or control the fire. 4. TECHNICAL DATA APPROVALS Approved by the China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the chart on page 10 b. Spacing Requirements: Maximum spacing 15 ft. (4,6 m). Minimum spac- ing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65°F (-55 °C). Minimum Operating Pressure: 7 psi (48,3 kPa). Rated to 175 psi (1 207 kPa) water work- ing pressure. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-051000 or Cop- per UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C1 1000 and Stainless Steel UNS-S30400 AVAILABLE FINISH Chrome-Enloy (patents pending) ACCESSORIES Sprinkler Wrenches: Standard wrench: Part Number 10896W/B (available since 2000) or 05000CWIB (no longer available). Wrench for recessed Standard Re- sponse Sprinklers: Part Number 07398W** (available since 1990), or Part Number 12144W/B**, available since 2003. NOTE: Re- cessed pendent sprinklers with protective caps must use wrench 12144W1B. °°A W ratchet is required (not available from Vi- king). Refer to the "Sprinkler Accessories" section of the data book. 5. AVAILABILITY AND SERVICE Viking products are available through a network of domestic, Canadian, and international distributors. See the Viking Corp. Web site for your closest distribu- tor or contact The Viking Corporation. Viking technical data may be found on The Viking Corporation's Web site at hftp:/Iwww.vikingcorp.com. The Web site may include a more recent edition of this technical data page. Sprinkler 12727FB with a standard 1/8" (3,1 mm) surface-mounted escutcheon. Ceiling Opening Size: 2-5/16" (59 mm) Minimum, 2-1/2" (64 mm) Maximum. 2-1/8- 2 1/8 (54 mm)— ......... (54 mm) MEM Maximum* Maximum mm) Sprinkler 12727FB Sprinkler 12727FB installed with a Microfast® Model F-i Adjustable Escutcheon. Figure 1 Sprinkler 12727FB installed with a Micromatid Model E-i Recessed Escutcheon. Note: Units of measure in parentheses maybe approximations. New page 10 a-b, dated March 5, 2004. Refer to technical data Form No. F 061303 page SRI-2 for general care, installation, and maintenance - information. Sprinkler 10 March 5, 2004 CCCF APPROVED STANDARD RESPONSE SPRINKLER (Part Number 12727F21 Approval Chart4 Temperature KEY Finish CCCF =d Standard Res Pendent Sprinkler 12727F Al X4— Escutcheon (if applicable) Maximum PSI _175_ _WWP Thread Size Nominal K-Factor Overall Length Temperature Classification Nominal Temp. Rating (Fusing Point) Maximum Ambient Ceiling Temperature 1 Bulb Color CCCF Approval2 NPT I BSPU S. metric5 Inch I mm h/2 15mm 5.6 1 8,1 2-3/16 1 56 Ordinary 155°F (68 °C) 100°F (38 °C) Red AiX Approved Escutcheons3 Approved Temperature Rating Approved Finish x - Standard surface-mounted escutcheons orthe Microfast® Model F-i Adjustable A - 155°F (68 °C) 1 - Chrome-Enloy® Escutcheon, or recessed with the Micromatic Model E-i Recessed Escutch- eon Footnotes Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2Approved, China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered separately from sprinklers. Refer to Viking's current price schedule. This table shows the listings and approvals available at the time of printing. 5Metnc K-factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factor shown by 10.0. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). New page 10 a-b, dated March 5, 2004. Refer to technical data page SRI-2 for Form No. F 061303 general care, installation, and maintenance information. March 5, 2004 Sprinkler 10 a 1. PRODUCT NAME Viking CCCF Approved Standard Re- sponse Pendent Sprinkler Part Number 12727FB Available since 2004. 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION Viking CCCF Approved Standard Re- sponse Sprinkler Part Number 12727 is a small thermosensitive spray sprinkler available with a 155 °F temperature rat- ing and chrome finish. The small frame and 5 mm glass bulb provide a pleasing appearance During fire conditions, the heat-sensi- tive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler ori- fice strikes the sprinkler deflector, form- ing a uniform spray pattern to extinguish or control the fire. 4. TECHNICAL DATA APPROVALS Approved by the China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the chart on page 10 b. Spacing Requirements: Maximum spacing 15 ft. (4,6 m). Minimum spac- ing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65 ¶ (-55 °C). Minimum Operating Pressure: 7 psi (48,3 kPa). Rated to 175 psi (1 207 kPa) water work- ing pressure. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-051000 or Cop- per UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C1 1000 and Stainless Steel UNS-530400 AVAILABLE FINISH Chrome-EnIoy (patents pending) ACCESSORIES Sprinkler Wrenches: Standard wrench: Part Number 10896W/B (available since 2000) or 05000CW/B (no longer available). Wrench for recessed Standard Re- sponse Sprinklers: Part Number 07398W** (available since 1990), or Part Number 12144W/B**, available since 2003. NOTE: Re- cessed pendent sprinklers with protective caps must use wrench 12144W/B. "A W ratchet is required (not available from Vi- king). Refer to the "Sprinkler Accessories" section of the data book. 5. AVAILABILITY AND SERVICE Viking products are available through a network of domestic, Canadian, and international distributors. See the Viking Corp. Web site for your closest distribu- tor or contact The Viking Corporation. Viking technical data may be found on The Viking Corporation's Web site at http://www.vikingcorp.com. The Web site may include a more recent edition of this technical data page. Sprinkler 12727FB with a standard 1/8" (3,1 mm) surface-mounted escutcheon. Ceiling Opening Size: 2-5/16" (59 mm) Minimum, 2-1/2" (64 mm) Maximum. 2-1/8- 2 1/8 (54 mm)- ... (54 mm) mm) Maximum* Maximum Sprinkler 12727FB Sprinkler 12727FB Sprinkler 12727FB installed with a Microfast® installed with a Micromati® Model F-i Adjustable Escutcheon. Model E-i Recessed Escutcheon. Note: Units of measure in parentheses maybe approximations. New page 10 a-b, dated March 5, 2004. Refer to technical data Form No. F_061303 page SRI-2 for general care, installation, and maintenance information. Sprinkler 10 b March 5, 2004 CCCF APPROVED A A A STANDARD RESPONSE N11a SPRINKLER Part Number 12727FB Approval Chart4 I Temperature KEY Finish CCCF Approved Standard Response Pendent Sprinkler 12727FB AIX+- Escutcheon (if applicable) Maximum PSI _175_ _WWP Thread Size Nominal K-Factor I Overall Length Temperature Classification I Nominal Temp. I Rating (Fusing Point) Maximum Ambient I Ceiling Temperature 1 I I I Bulb Color I CCCF Approva12 I NPT I BSPU S. metrics Inch mm 15mm 5.6 8,1 2-3/16 I 56 Ordinary I 155°F (68 °C) I 100°F (38 °C) I Red AiX Approved Escutcheons3 Approved Temperature Rating Approved Finish X -Standard surface-mounted escutcheons ore Microfast® Model F-i Adjustable A - 155°F (68 °C) 1 - Chrome-Enloy5 Escutcheon, or recessed with the Micromatic Model E-1 Recessed Escutch- eon Footnotes 1 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2Approved, China Certification Center for Fire Products (CCCF), standard GB5135-1993. Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered sprinklers. current price schedule. separately from Refer to Vikings 4 This table shows the listings and approvals available at the time of printing. 5Metnc K-factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factor shown by 10.0. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). New page 10 a-b, dated March 5, 2004. Refer to technical data page SRI-2 for Form No. F_061303 general care, installation, and maintenance information. Sprinkler 12727FB March 5, 2004 Sprinkler 10 a 1. PRODUCT NAME Viking CCCF Approved Standard Re- sponse Pendent Sprinkler Part Number 12727FB Available since 2004. 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION Viking CCCF Approved Standard Re- sponse Sprinkler Part Number 12727 is a small thermosensitive spray sprinkler available with a 155 "F temperature rat- ing and chrome finish. The small frame and 5 mm glass bulb provide a pleasing appearance. During fire conditions, the heat-sensi- tive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler ori- fice strikes the sprinkler deflector, form- ing a uniform spray pattern to extinguish or control the fire. 4. TECHNICAL DATA APPROVALS Approved by the China Certification Center for Fire Products (CCCF), standard G85135-1993. Refer to the chart on page 10 b. Spacing Requirements: Maximum spacing 15 ft. (4,6 m). Minimum spac- ing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65 "F (-55 "C). Minimum Operating Pressure: 7 psi (48,3 kPa). Rated to 175 psi (1 207 kPa) water work- ing pressure. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-051000 or Cop- per UNS-C 19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 AVAILABLE FINISH Chrome-Enloy' (patents pending) ACCESSORIES Sprinkler Wrenches: Standard wrench: Part Number 10896W/B (available since 2000) or 05000CWIB (no longer available). Wrench for recessed Standard Re- sponse Sprinklers: Part Number 07398Wk* (available since 1990), or Part Number 12144W/B**, available since 2003. NOTE: Re- cessed pendent sprinklers with protective caps must use wrench 121 44W/B. ""A %" ratchet is required (not available from Vi- king). Refer to the "Sprinkler Accessories" section of the data book. 5. AVAILABILITY AND SERVICE Viking products are available through a network of domestic, Canadian, and international distributors. See the Viking Corp. Web site for your closest distribu- tor or contact The Viking Corporation. Viking technical data may be found on The Viking Corporation's Web site at http://www.vikingcorp.com. The Web site may include a more recent edition of this technical data page. Ceiling Opening Size: 2-5/16" (59 mm) Minimum, 2-1/2" (64 mm) Maximum. Sprinkler 12727FB with a standard 1/8" (3,1 mm) surface-mounted escutcheon 2-1/8" (54 mm) mom 2" 1-1/2" (.38 Minimum Sprinkler 12727FB installed with a Microfast® Model F-i Adjustable Escutcheon. Sprinkler 12727FB installed with a Micromatid5 Model E-1 Recessed Escutcheon. Figure 1 I Note: Units of measure in parentheses maybe approximations. New page 10 a-b, dated March 5, 2004. Refer to technical data Form No. F 061303 page SRI-2 for general care, installation, and maintenance - information. Sprinkler 10 March 5, 2004 CCCF APPROVED ST N41 KJ STANDARD RESPONSE SPRINKLER (Part Number 12727FB) Approval Chart4 Temperature KEY I - Finish CCCF Approved Standard Response Pendent Sprinkler 12727FB Al X*— Escutcheon (if applicable) Maximum 175 PSI WWP Thread Size Nominal I K-Factor Overall Length Temperature Classification I Nominal Temp. i Rating (Fusing Point) I Maximum Ambient I Ceiling Temperature' Bulb Color CCCF I Approva12 I NPT T BSPUI S. I metric5 I In I mm 15mm 5.6 8,1 2-3/16 1 56 I Ordinary 155°F (68 °C) I 100 °F (38 °C) I Red I AiX Approved Escutcheons3 Approved Temperature Rating Approved Finish X - Standard surface-mounted escutcheons ore Microfast® Model F-i Adjustable A - 155 °F (68 °C) 1 - Chrome-Enloy® I Escutcheon, or recessed with the Micromatic Model E-1 Recessed Escutch- eon Footnotes Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2Approved China Certification Center for Fire Products (CCCF), standard G135135-1993. Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered separately from sprinklers. Refer to Viking's current price schedule. This table shows the listings and approvals available at the time of printing. 5Metnc K-factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factor shown by 10.0. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). New page 10 a-b, dated March 5, 2004. Refer to technical data page SRI-2 for Form No. F_061303 general care, installation, and maintenance information.