Loading...
HomeMy WebLinkAbout2105 RUTHERFORD RD; ; AS100093; Permit10/27/21, 12:29 PM AS100093 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS100093 2105 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2121202000 Lot #: 0 Status: ISSUED Applied 7/30/2010 Approved: 7/30/2010 Reference No.: Issued: 7/30/2010 PC #: Inspector: Project Title: GENOPTIX TWO FIRE INSPETIONS @ $65/EA Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: BLACKMORE RUTHERFORD INVESTMENT P0 BOX 424 RANCHO SANTA FE CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 F I Genoptix Customer Service Center TI Review Comments. Page 2 Review Comments Genoptix Customer Service Center TI, 2105 Rutherford Road, Carlsbad, CA Verify that the end sprinkler on each branch line is provided with vertical restraint, per NFPA- 13, section 9.3.6.3. This can be waived if the hanger rods supporting that pipe are not in excess of 6" long, when between the top of the pipe and the point of attachment to the building structure. Verify that lateral restraint of the branch lines is provided at spacing matching that required in NFPA-13 table 9.3.6.4 (attached), based on a Cp value of 0.70 (used for seismic brace calculations). This also can be waived if the hanger rods supporting that pipe are not in excess of 6" long, when between the top of the pipe and the point of attachment to the building structure. Since the available static pressure is in excess of 100 psi, and the branch lines do supply sprinklers to drops below a ceiling, verify that any armover, 12" or longer, is provided with a hanger, per NFPA-13, section 9.2.3.5.2.1. Table 9.3.6.4(a) Maximum Spacing (it) of Steel Branch line Restraints (ft) Seismic Coefficient (C1) Pipe (in.) Cp <O.50 0,71 Cp > 0.71 1 43 36 26 1'/4 46 39 27 1½ 49 41 29 2 53 45 31 I ASt000lS Flow Test Record F ILE COPY Test Hydrant Location t. £ ( Lt, 4. '' z r Hydrant ID No. Size Main______ Static ............ .t25 Residual........... Pressure Drop.. jOftT (PDI I).....K factor for JDX 1 Flow Hydrant(s) Hydrant 1 location Hydrant 2 location Hydrant 3 location Hydrant 1 Pitot--95______PSI GPM:jS4-1) Size of Orifice 2 12... Hydrant 2 Pitot PSI GPM: Size of Orifice___________ Hydrant 3 Pitot PSI GPM: Size of Orifice___________ TotJ: kVII ___________ (A1\ Calculated test and flow data - Qx PD2 k = Q2 PDIk Static: Desired Residual ....... .20 Pressure Drop (PD 2).. K factor PD 2: x divided by equals GPM at 20 psi residual Q PD2k PDIk Q2 re- Conducted by: —(—& A4LAJ JlfHi 4- 1t-I Ft' y Date:_9Zjj Time: JO Carlsbad Municipal Water District Potable Water Discharge Event Report Date: 7/2fF0 Location 2IQ FCb Reason for Discharge Event: R..E1'4.OIEEL__ Type of Event: Dewatering Water Mains Note: Includes flow testing and flushing Dewatering Reservoirs Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetatioTh. Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharge water. Initial IA Estimated Discharge Flow: 134Q &1'M Start Time k End Time )QOL Pre-Dechlorination Residual: Q q I Post- Dechlorination Residual: (less than 0,1 mg/L) pH within limits of 6.0 and 9.0 (sLj.5 Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. t Upon completioncompletion of dewatering, ensure that any sediment or silted areas are cleared. 1 Water Sampling Performed by: Comments: Submitted by: Reviewd by: (Name & Date) (Name &