Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; FS090004; Permit10/28/21, 9:25 AM FS090004 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS090004 Job Address: 2200 FARADAY AV Status: ISSUED Permit Type: FIXSYS Applied 1/20/2009 Parcel No: 2121204100 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: SIERRA WIRELESS SPECIAL CHEMICAL PLAN CHECK & INSPECTION Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: GRANDONA INVESTMENT ASSOCIATES L P 2610 HARRISBURG AVE FREMONT CA Fees ($) Add'I Fees ($) Total ($) 1IL Balance ($) _130 0 130 1/1 4 Sprinkler Base Part No. 09849 Sprinkler Base Part No. 10224 4 February 6, 2009 Sprinkler 14e ;,. . • ___________________ , TECHNICAL RESPONSE SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Micromatic and MicromaticHPe Standard Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester and Teflon5 coatings can be used in decorative applications where colors are de- sired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon5 and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 14f. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2012 and 2015 LPC Approved: Ref. No. 096e/06 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003 Refer to the Approval Chart on page 14g and Design Criteria on page 14h for cULus Listing and FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1996. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers VKII6 and VK015 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Viking Technical Data may be found on The Viking Corporation's Web site at http:/Iwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Overall Length: Refer to the Approval Chart *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bushing (for high pressure sprinkler 09997): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31600 or UNS-C31400 for Sprinklers 10171 and 10224. For all others: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment (for sprinklers 09849 and 09997): Brass UNS-C36000 For Teflon5 Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon5 Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Form No. F123096 Replaces page 14e-j, dated October 12, 2007. (Updated LPCB Approval for Sprinkler VK104. Added G-1 Escutcheon. Mm. operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Sprinkler 14f February 6, 2009 . .................. Mi iI* V [ - I -, ...T.CHNICL PAT RESPONSE HORIZONTAL . SIDEW LL SPRINKLERS . - The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, ChromeEnloye = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflone = N, Wax Coated = C, Wax Over Polyester = V-/W Temperature Suffix (°F/°C): 135°I68° A, 155°/68° = B, 175°/79° = D, 200°/93° = E, 212°/100° = M, 286°/141" = G, 360°I182° = H, OPEN = Z (Teflon' only). For example, sprinkler VK104 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No, 10224A8 Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) Wrench for wax coated sprinklers: Part No. 13577W/B** (available since 2006) **A '/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Standard Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Protective Flat ID sprinkler ShieLd 896 :=101 Figure 1: Standard Sprinkler Wrench 10896W!B February 6, 2009 Sprinkler 14g .1 .RESPONSE .. & 'i j1 1!SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com TABLE 1. AVAILABLE 1WIRINKLER TEMPERATURE RATJNGS' W&FINISHE Sprinkler Temperature Sprinkler Nominal Maximum Ambient IJ Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 "C) 100 "F (38 00) Red Intermediate 175 °F (79 00) 150 "F (65 "C) Yellow Intermediate 200 °F (93 00) 150°F (65 00) Green High 286 °F (141 "0) 225 "F (107 00) Blue Extra High 360 "F (182 "0) 300 °F (149 "0) Mauve Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester for sprinklers with the following temperature ratings: 135 "F (57 "C) Off-White Wax 155 "F (68 00) Lt. Brown Wax 175 "F (79 00) Brown Wax 200 "F (93 00) Brown Wax 286 "F (141 00) Dk. Brown Wax4 Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Wax melting point is 170 "F (76 "0) for 286 "F (141 00) temperature rated sprinklers. Sprinkler Wrench Port No. 13655\'I/B)IE or Recessed Horizontal Sidewoll Sprinklers Fit the wrench over the sprinkler and protective shield as shown. - II // I I 11 I III II I I/I I --I xNote: A 1/2" ratchet is required (not available from Viking) Figure 2: Wrench 13655W/13 for Recessed Horizontal Sidewall Sprinklers Sprinkler 14h February 6, 2009 _TICALDATA* Iii The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart T- P" KEY I - __• Micromatic" and MicromaticHP7 Standard Response Horizontal Sidewall Sprinklers A1X+ __t -Eiutcheon ap.h5b c1(1 Maximum 175 PSI (12 Bar) WWP (SeeFootnotesBelowforAllowableDeflectorDistanceBelowtheCeiling.) Base Part SIN Maximum I Thread Size I Nominal K-Factor Overall Length I Listings and Approvals' J (Refer alsoto Design Criteria onpg14i.) Number' Pressure I_I NPT f_BSP U.S. _U.S.j_metric2j_ Inches j_mm _FM5 _______________________ _NYC7 _LPCB Standard Orifice 10224 I_VK104 -7/16 I_62.4 B5W, B1W. Al X: C6X I A3X, 63Y I B5V, B1V, AlX, C6X A2Z, B57 D2Z D2Z 10171 _VK1O4 175 psi _175psi I_1/2"I 15mm _--_15mm _5.6 _-- _80.6 I 2 _80.6 _2-7/16 _62.4 Small Orifice 62.4 [--LU—Lus I FM I NYC L PCB J 0 09126 VK016 175 psi -- 10mm 4.2 60.5 2-7/16 - _-- _--_I_-- Maximum 250 PSI (17 Bar) WWP StandardOrifice,forInstallation 4"to12"(102mmto305mm)BelowtheCeiling. cULus4'8 1 FM I NYC LPCB I (( I 09849 VK116 250 psi 1/2" 15mm 5.6 80.6 2-11/16 67.6 _--_--_--_--_I_-- AiX,B1W Maximum 250 PSI (17 Bar) WWP Small Orifice9, for Installation 4"to6"(102mmto152 mm) Below the Ceiling. I us 4,9 I FM I_NYC LPCB I ( 0999712 VKO15 250 psi 1/2" 15 mm 2,8 40.3 2-3/4 69 B1W -- _--_I_--_I_-- I Approved Escutcheons V - Installed with standard surface-mounted Approved Temperature Ratings Approved Finishes escutcheons or the Viking Microfast Model 1 - Brass, Chrome-Enloy', White Polyester1314, Black Poly- F-i Adjustable Escutcheon's, or recessed A- 135°F (57 "C), 155°F (68 "C), 175 "F ester 314, and Black Teflon 113 with the Viking Micromatic Model E-1 or E-2 (79 "C), 200°F (93 "C), 286 "F (141 "C), 2 - Brass, Chrome-EnIoy5, White Polyester, and Black Poly- Recessed Escutcheon and 360 "F (182 "C) ester W - Installed with standard surface-mounted B - 135°F (57 "C), 155 "F (68 "C), 175 "F 3 - Brass and Chrome-Enloyo escutcheons or the Viking Microfast Model (79 "C), and 200 "F (93 "C) 4 - Wax-Coated Brass (corrosion resistant), White Poly- F-i Adjustable Escutcheon'-', or recessed C - 286 "F (141 "C) ester, and Black Polyester with the Viking Micromatic Model E-1, E-2, D - 155 "F (68 "C), 175 "F (79 "C), 200 "F 5 - Wax-Coated Brass and Wax Over Polyester (corrosion or Model G-1 Recessed Escutcheon X (93 "C), 286 "F (141 "C), and 360 "F resistant) - Installed with standard surface-mounted es- (182 "C) 6 - High Temperature 200 "F (93 "C) Wax Coating (corro- cut cheons or the Viking Microfast11 Model F-i E - 155 "F (68 "C), 175 "F (79 "C), and sian resistant); maximum ambient temperature allowed Adjustable Escutcheon's V - Recessed with the Viking Model G-1 Recessed "F "C) 200 (93 at ceiling = 150 "F (65 "C) Escutcheon Z - Installed with standard surface-mounted es- cutcheons only Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. "cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied, with the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. 6FM Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with the deflector 4" to 6" (102 mm to 152 mm) below the ceiling. 7Approved by the New York City Board of Standards and Appeals under Calendar Number 219-76-SA. cULus Listed for Light Hazard Occupancies where allowed by the installation standards being applied, and Ordinary Hazard Group I and II Occupancies. cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems. Certified, Standard EN 12259-1 EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. " 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. "The sprinkler orifice is bushed. '3cULus Listed as corrosion-resistant. "Other colors are available on request with the same Listings and Approvals as the standard colors. !'The Viking Microfast' Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. February 6, 2009 Sprinkler 14i . • k' II 1 I nfl. N&DT 4m L *h .4 4 RESPONSE HORIZONTAL II !A Ui The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 14h.) cULus Listing Requirements: Standard Horizontal Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in occupancy hazard classifications as indicated in the approval chart, below smooth, flat ceilings only. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. FM Approval Requirements: Standard Horizontal Sidewall Sprinklers are FM Approved for Light Hazard occupancies only, as indicated in the Approval Chart, for installation in ac- cordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No, F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Carefully press the wrench onto the sprinkler wrench flats. : [ILilIIjE': **A 1/2" ratchet is required (not available fron Viking). w'rerrch 13577'J/Brx for installing wax coated sprinklers Sprinkler 14j February 6, 2009 PER, A* -*A Aw Aw- RESPONSE HORIZONTAL - SIDEWALL SPRINKLERS A!A The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com WaU Opening Size: 2-5/16' (58.7 mm) minimum 2-1/2" (63,5 mm) maximum 2-7/16' (50.8 mm) 2-11/16' (61.9 mm) mm) Minimum mum (54 mm) 4 (15 mm) NPI HSW Sprinkiec 2-1/2' 09849 (VK116) (63,5 m) Installed with a standacd Maximum I m 1/8" (3,1 mm) surface- mounted escutcheon Installed with a Microfast Model F-i Adjustable Escutcheon Figure 4: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon A Wak Opening Size with the Model C-I or-E-2 Escutcheon. fl 1 1-3/4' 2-5/16 58.7 nM, n:n:mum Minimum 2" (63.5 mm) maximum 4.5mn) M:ninum 2-1/4" 25/8" I- (57.2 mm) Maximum Mo ximurn Installed with a Model E Installed with.a M:cromat:c nread-on Recessed Escutcheon Model E-1 Recessed Escutcheon Figure 5: Sidewall Sprinkler Dimensions with the Model E-I or E-2 Recessed Escutcheons Wall Opening Size with the Model 8-1 Escutcheon: 1/8" - 2-3/8 66 mm; minimum u ... mm, 3-3/4' (135 mm, rlax;nufl Adjustable Outer Cup \ Adapter \ Ring 4' (6E,mm) (102 mm) Depth Hi (27 mm) Maximum Recess: (27 mm) 1/2' (12.7 mm) Figure 6: Sidewall Sprinkler Dimensions with the Model G-1 Recessed Escutcheons Form No. F_123096 Replaces page 14e-j, dated October 12, 2007. (Updated LPCB Approval for Sprinkler VK104. Added G-1 Escutcheon. Mm. operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Schmidt Fire Protection Co., Inc. 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123• (858) 279-6122 • FAx (858) 279-3583 SIERRA WIRELESS 224)OOSMOS-CT. QZ7 2Iy' SAN DIEGO, CA 92009 SUBMITTAL PACKAGE (1) FM-200 FIRE SUPPRESSION SYSTEM -SERVER ROOM APPROVEDAS IJ:]!tl iiiI I.- cethz of ce 4w"2 oti thmo S S or Kidde Fire Systems JAMES MOORE SCHMIDT FIRE PROTECTION CO. 4760 MURPHY CANYON RD. SAN DIEGO, CA Phone: PH: 858-279-6122 FAX: 858-279-3583 ECS Series - KID3.03 UL: EX4674 Project: SIERRA WIRELESS File Name: 649-Sierra Wireless. FLC Consolidated Report Customer Information Company Name: SIERRA WIRELESS Address: 2290 COSMOS CT. CARLSBAD, CA 92009 Phone: Contact: Title: Project Data Project Name: SIERRA WIRELESS Designer: Number: Account: Location: Description: Page: 1 of Calculation Date/Time: Tuesday, January 13, 2009, 12:19:15 PM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal jKidde Fire Systems Consolidated Report Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: I Enclosure Number: Name: Enclosure Temperature... Minimum: Maximum: Maximum Concentration: Design Concentration... Adjusted: Minimum: Minimum Agent Required: Width: Length: Height: I ANECHOIC CHAMBER 70 F 70 F 7.021 % 7.021 % 7.000% 74.8 lbs 0.0 ft 0.0 ft 0.0 ft Volume: 0.0 cubic ft Non-permeable: 0.0 cubic ft S Total Volume: 2191.9 cubic ft Adjusted Agent Required: 75.0 lbs Number of Nozzles: I Page: 2 of 5 Calculation Date/Time: Tuesday, January 13, 2009, 12:19:15 PM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal fKidde Fire Systems Consolidated Report Agent Information Agent: FM-200 / Propellant N2 (FM-200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 75.0 lbs Container Name: 125 lb Cylinder w/LLI Container Part Number: 90-100121-001 Number of Main Containers: 1 Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Horizontal Agent Per Container: 75.0 lbs Fill Density: 41.9 lbs / cubic ft Container Empty Weight: 96.0 lbs Weight, All Containers + Agent: 171.0 lbs Floor Area Per Container: 0.89 square ft Floor Loading Per Container: 192 lbs / square ft Pipe Network Part I - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl. X 1 0 . 1 1-1/2 in 2.99 ft 2.99 ft Adapter 1 2 1-1/2 in 0.22 ft 0.00 ft Pipe 2 3 40T I in 11.00 ft 11.00 ft Pipe 3 4 40T 1 in 6.50 ft 0.00 ft Pipe 4 5 40T I in 1.25 ft 0.00 ft Pipe/El-NI 5 6 40T I in 1.00 ft -1.00 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 50.0 ft 1 2 0 0 0 0 0 1-1/2inVOA 0.00 ft 11.8 ft • Page: 3 of 5 Calculation Date/Time: Tuesday, January 13, 2009, 12:19:15 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal 'Kidde Fire Systems Part 2 - Equivalent Length Start End 90 45 Consolidated Report Thru Side Union Other Added Total 2, 3 1 0 0 0 0 0.00 ft 13.8 ft 3 4 1 0 0 0 0 0.00 ft 9.3 ft 4 5 1 0 0 0 0 0.00 ft 4.1 ft 5 6 1 0 0 0 0 0.00 ft 3.8 ft Part 3 - Nozzles Start End Flow Name Size Type Nozzle Area 0 1 75.0 lbs 1 2 75.0 lbs 2 3 75.0 lbs 3 4 75.0 lbs 4 5 75.0 lbs 5 6 75.0 lbs El-Ni I in 1800 0.3504 square in Parts Information Total Agent Required: 75.0 lbs Container Name: 125 lb Cylinderw/LLI (Part: 90-100121-001) Number Of Containers: 1 Nozzle Type Nozzle Area Part Number El-NI 1800 0.3504 square in 90-194015-234 Pipe: Type Diameter Length 40T 1 in 19.75 ft 'Other Items: I - 1-1/2 in. Valve Outlet Adapter (Part: 283904) List of 90 degree elbows: 4 - I in System Acceptance * WARNING - The data in this project may have been changed after the calculations were Page: 4 of 5 Calculation Date/Time: Tuesday, January 13, 2009, 12:19:15 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal O.r Fire Systems Consolidated Report performed. System Discharge Time: 8.8 seconds Percent Agent In Pipe: 17.7% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: ANECHOIC CHAMBER Minimum Design Concentration: 7.000% Adjusted Design Concentration: 7.021% Predicted Concentration: 7.021% Maximum Expected Agent Concentration: 7.021% (At 70 F) Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Nozzle Required Required Delivered (Average) El-Ni 74.8 lbs 75.0 lbs 75.0 lbs 172 psig Standard Isometric View E Cl-N 1 3 NkVOA 1 X 125 lb Cilir4er w/LLl . No Manifold w Page: 50f5 . Calculation Date/Time: Tuesday, January 13, 2009, 12:19:15 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal . ry A CD r. NJ APROX, 4O" 1" • 1" UNI ON i(EiK nE A D X " RLDUCL'" LcJ I [(\\u1 fu` L FM 200 - r1. L[II.. L 0. h:\ I ., PIPING ISOMETRIC. L (V H T 'L.. F L I 41 [P V) . iN ft. B 3u1 M 4It'9 (' PKLR('( D çT W . . \;'J.,E. F FM-200® Fire Suppression Agent / jfrKiddeFire Systems Effective: February 2004 K-90-1900 FEATURES Non-Ozone Depleting . Fast Acting Safe for Total Flooding of Occupied Spaces • Active Fire Suppression Agent Clean-No Residue to Clean Up • UL Component Recognized Non-Damaging to Hazard Contents • FM Approved EXTINGUISHING AGENT USE I FM-200 (1,1,1,2,3,3,3-heptafluoropropane) is a compound of carbon, fluorine and hydrogen (CF3CHFCF3). It is colorless, odorless and electrically non-conductive. It suppresses fire by a combination of chemical and physical mechanisms without affecting the available oxygen. This allows personnel to see and breathe, permitting them to leave the fire area safely. FM-200 has acceptable toxicity for use in occupied spaces when used as specified in the United States Environmental Protection Agency (EPA) Significant New Alternative Policy (SNAP) program rules. Although FM-200 is considered non- toxic to humans in concentrations necessary to extinguish most fires, certain safety considerations should be observed when applying and handling the agent. The discharge of FM-200 may create a hazard to personnel from the undecomposed agent itself and from the decomposition products which result when the agent is exposed to fire and other hot surfaces. Ex- posure to the agent is generally of less concern than is expo- sure to the decomposition products. Unnecessary exposure to the agent or the decomposition products should be avoided. TOXICITY In tests, the acute toxicity of FM-200 was shown to be equiva- lent to that of Halon 1301. FM-200 has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA's SNAP Program classifies FM-200 as ac- ceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP program rules for more information. CLEANLINESS FM-200 is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive "down-time" to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics, rubber and electronic components are unaffected by expo- sure to FM-200. APPROVALS FM-200 is used in total flooding fire suppression systems. It is stored in steel containers, and is super-pressurized with nitro- gen to aid in expelling the agent The discharge time is 10 seconds or less. The maximum fill density of the agent Storage is 70 lb/ft.3. Table 1. FM-200 Physical Properties Chemical Formula CF3CHFCF3 Molecular Weight 170.03 Freezing Point -204°F (-131°C) Boiling Point at 1 Atm. 2.6°F (-16.4°C) Critical Temperature 215.1°F (101.7°C) Critical Density 38.76 lb./ft3 (621 kg/m3) Critical Pressure 422 PSIA (29.0 bar absolute) Critical Volume 0.0258 cu.ftJlb. (1.61 L/kg) Ozone Depletion Potential 0 Table 2. FM-200 Fire Protection Properties Cup Burner Concentration (n-Heptane) 6.70% v/v Use Concentration for n-Heptane 8.00% v/v Use Concentration for Acetone 8.30% v/v Use Concentration for Isopropanol 9.00% v/v Use Concentration for Toluene 7.00% v/v Use Concentration for Class A (Surface Fires)* 6.25% v/v "Note: Automatic only per NFPA 2001. Table 3. FM-200 Toxicity Properties NOAEL 9.00% (No Observable Adverse Effect Level) LOAEL 10.50% (Lowest Observable Adverse Effect Level) FM-200 agent complies with the NFPA Standard 2001: Standard for Clean Agent Fire Extinguishing Systems, EPA - SNAP Program (Significant NewAlternate Policy), Underwrit- ers Laboratories, Inc. (UL) and Factory Mutual Research Cor- poration (FMRC). FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE-FENWALINC. assumes no Kidde Fire Systems responsibility for the product's suitability for a particular application. The product must be p 400 Main Street 11 erly applied to work correctly. Ashland, MA 01721 USA I If you need more information on this product, or if you have a particular problem or question, I contact KIDDE-FENWAf. INC.. Ashland, MA 01721. Telephone: (508) 881-2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-90-1900 02/04 ©2004 Kidde-Fenwal, Inc. Printed in USA http://www.kiddefiresystems.com 1~ FM-200® Component Description Cylinder and Valve Assembly 125 lb. (56.7 kg) Capacity ill Kidde Fire S ystems Effective: April 2002 K-90-2030 FEATURES For use with UL Listed, ULC Listed and FM Approved Systems P/N: 90-10012X-001 VALVE OUTLET PLAN VIEW ORDERING INFORMATION Part Number Description 90-100121-001 wILLI 90-100125-001 STD liVE itO LEVEL INDICATOR IFTING LUGS CYLINDER MATERIALS Valve Body: Cylinder: Brass Steel, Painted Red 35.93. CYLINDER NAMEPLATE 12,75 DIA Note: 1, The safety cap must be installed on the valve outlet at all times, except when the cylinders are connected to the system piping, or being filled. The safetly cap must not be removed from its chain. 2. See K-90-2020 for additional information. FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE-FENWALINC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2030 04/02 02002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddeftresystems.com FM-200® Component Description Valve Outlet Adapters ~00r Kidde Fire Systems Effective: April 2002 K-90-2100 FEATURES For use with UL Listed, ULC Listed and • See Kidde® Manual 90-FM200M-021 for FM Approved Systems USCG Approval P/N: 28390X B (VALVE OUTLET CONNECTION) C A (SYSTEM PIPE CONNECTION) Note: For direct connection of cylinder valve to distribution piping. MATERIAL Brass ORDERING INFORMATION Part Size A* B* C Number 1% 1.874 283904 1% 2.69 2.50 HEX 1IY2NPT I2UNJ 2 2. 500 283905 2 11%NPT 12UNJ 3.12 3.00 HEX 2% 3.00 3.00 283906 283906 21/2 8NPT 3.00 3.75 HEX *Note: Dimensions are in inches. FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE-FENWAL,INC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2100 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://wwW.kiddefiresysterns.com ORDERING INFORMATION PART NUMBER . CONTROL HEAD VOLTAGE CURRENT 890181 24VDC 2.OA 890149 125 VDC 0.3A 890165 115 VAC 1.OA K-90-8010 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA This literature is provided for informational purposes only. KIDDE-FENWAL,lNC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com FM-200® Component Description Electric Control Head jer,Kidde Fire Systems Effective: April 2002 K-90-8010 FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems P/N: 8901XX CONNECTION FOR FLEXIBLE ELECTRIC CONDUIT- 3/4" NPT FEMALE LOCKING PIN SEAL WIRE — I, ELECTRIC J FM-200 is a registered trademark of the Great Lakes Chemical Corporation. CONTROL HEAD 6.18" VOLTS NtPS (157mm) 0 INDICATOR AND TO RESET RESET STEM SET RELEASED MADE IN U. A. & 4.00" (102mm) LOCAL MANUAL RELEASE LEVER SWIVEL NUT 1.50" (38mm) HEX 1-114"-18 NF-3 THREAD In-Line Releasing Device Installation Instructions j'r"..Kidde Fenwal Effective: November 2004 DESCRIPTION The In-Line Releasing Device, P/N 06-220023-001, is used to make a single-or dual-solenoid releasing circuit power limited. See Figure 1. Figure 1. In-Line Releasing Device SUPPLIED PARTS In-Line Releasing Device, PIN 06-220023-001 REQUIRED TOOLS No. 2 Fiat-Head Screwdriver. Small Flat-Head Screwdriver. PROCEDURE The In-Line Releasing Device is polarity-sensitive and must be connected as shown in Figure 2 for a single- solenoid circuit or as shown in Figure No. 3 for a dual- solenoid circuit. The red lead of the In-Line Releasing Device must be connected to the field wiring from Terminal I of the ré- leasing circuit. The black lead must be connected to the control head or solenoid valve. Use wire nuts to connect the In-Line Releasing Device to field wiring and leads from control heads and sole- noid valves. Black Control Head for Agent Storage Red Container or \<Lin Releasing DevicU"7 Black Solenoid valve for Sprinkler System Rhl Release- or Combo- Circuit Terminals JUNCTION BOX (enlarged for clarity) Note: Junction box for In-Line Releasing Device must be close nippled to control head or enclosure for solenoid valve. Figure 2. Single-Control-Head or-Solenoid Releasing Circuit Red Black In-Line Releasing De JUNCTION BOX (enlarged for clarity) Control Head for Agent Storage Red Container or Black Solenoid Valve for Sprinkler System Control Head for Agent Storage Red Container or . Black . Solenoid Valve for Sprinkler System Release-Circuit Terminals .rn— Red ac In-Line Releasing Device Note: Junction box for In-Line Releasing Device must be close nippled to control head or enclosure for solenoid valve. Use separate junction boxes when control heads or solenoid valves are remote from each other. Figure 3. Dual-Control-Head or -Solenoid Releasing Circuit Kidde-Fenwal is a registered trademark of Kidde-Fenwal, Inc. ' L e is provided for informational purposes only. KlDDE-FENWAL,lNC. assumes no y for the product's suitability for a particular application. The product must be prop- to work correctly. more information on this product, or if you have a particular problem or question, E-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 06-236541-001 RevAA ©2004 Kidde-Fenwal Inc. Printed in USA I Kidde Fenwal Kidde-Fenwal, lnc.D 400 Main Streetfl Ashland, MA 01721 U.S.AO www.kidde-fenwal,com FM-200® Component Description 180 Degree Pendant Nozzle IjOr Kidde Fire Systems, Effective: April 2002 K-90-2150 FEATURES For use with UL, ULC and FM Approved Systems • See Kidde® Manual 90-FM200M-021 for USCG Approval P/N: 90-19401X-XXX METAL STAMP X-XXX (DASH NO.) IN .093 .031 HIGH CHARACTERS ON ANY FLAT S A 600 T) 30" / 180 DEGREE NOZZLE Pipe Size A B C D 1/2° (12.20mm) . 1.250" (31.75mm) 1.250" (31.75mm) 1.687' (42.84mm) 2.000" (50.80mm) 3/4" (19.05mm) 1.500" (38.10mm) 1.375" (34.92mm) 1.950" (48.89mm) 2.296" (58.31 mm) (25.40mm) 1.750" (44.45mm) 1.562" (39.67mm) 2.218" (56.33mm) 2.671" (67.84mm) 1-1/4" (31.75mm) 2.250" (57.15mm) 1.750" (44.45mm) 2.656' (67.46mm) 3.250" (82.55mm) 1-1/2" (38.10mm) 2.250" (63.50mm) 1.950" (48.89mm) 2.950" (74.93mm) 3.625" (92.07mm) (50.80mm) 3.000" (76.20mm) 1.968' (49.98mm) 2.875" (73.02mm) 3.656" (92.86mm) Note: A selection of orifices are available for each nozzle size. Consult your Kidde® design and installation manual for details. FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE.FENWAL,INC assumes no responsibility for the product's suitability for a particular application. The product must be prop- erty applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIODE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2150 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com FM-200® Component Description (jr Kidde Fire Systems Warning Nameplate (FM-200) - Effective: April 2002 K-90-9030 FEATURES For Use with UL Listed, ULC Listed and • See Kidde® Manual 90-FM200M-021 for FM Approved Systems USCG Approval P/N: 06-231865-739 10.000 0.063 0.340 9.360 'I 10.340 WARNING THIS AREA IS PROTECTED BY A 0.062 FM-200 EXTINGUISHING 5.000 4.360 SYSTEM. DO NOT ENTER WITHOUT AUTHORIZATION DURING OR AFTER DISCHARGE 0.281 .005 DIA. TYP. 4 HOLES MATERIALS Aluminum Type 1100—H14, 0.032 ± 0.003 Thick. All Letters to be 48 pt., Alternate Gothic #2, Etched 0.003 to 0.005 and Filled in With Red Chip Proof Enamel Color No. 21105 per Fed. Stc. 595 Finish: One Coat Clear Lacquer Both Sides 0 FM-200 is a registered trademark of the Great Lakes Chemical Corporation. I This literature is provided for informational purposes only. KIDDE-FENWALINC. assumes no Kidde Fire Systems I erly applied to work correctly. question, Ashland, MA 01721 USA If you need more information on this product or if you have a particular problem or quest I responsibility for the products suitability for a particular application. The product must be P r::] 400 Main Street contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-90-9030 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA http://www.kiddefiresystems.com KIDIX Welcome to the world of FEN AL Fire Protection! KIDDE-FENWAL AEGIS Fire Control Panel (This Calculation Form is taken from Appendix 'A' of the AEGIS Installation, Operation and Maint. Manual) Date: 13-Jan-09 Project: SIERRA WIRELESS 2290 Cosmos Ct. Carlsbad, CA 92009 Anechoic, Chamber BATTERY CALCULATIONS DEVICE QUANTITY Standby Current Load Total Standby Current Load Alarm Current Load Total Alarm Current Load CONTROL PANEL: Main Control Panel 1 0.1 amp 0.1 amp 0.24 amp 0.24 amp Auxiliary Power Output 0 1 amp 0 amp 1 amp 0 amp MCP Programmable Relay 3 0 amp 0 amp 0.02 amp 0.06 amp LED Display Module 0 0 amp 0 amp 0.04 amp 0 ahp FIELD DEVICES: 15 cd Horn/Strobe 1 0 amp 0 amp 0.067 amp 0.067 amp 75 c Horn/Strobe 0 0 amp 0 amp 0.142 amp 0 amp 75cd Ceiling Strobe 0 0 amp 0 amp 0.119 amp 0 amp Sync Module 0 0 amp 0 amp 0.017 amp 0 amp MT Horn 0 0 amp 0 amp 0.033 amp 0 amp 2-Wire Ionization Smoke Detector 0 0.00007 amp 0 amp 0.001 amp 0 amp 2-Wire Photoelectric Smoke Detector 3 0.00007 amp 0.00021 amp 0.001 amp 0.003 amp Detection Circuits 1 &2 2 0 amp 0 amp 0.07 amp 0.14 amp Contact Type Heat Detectors . 0 0 amp 0 amp 0 amp 0 amp DH-60 (2W) Duct Detectors 0 0.00007 amp 0 amp 0 amp 0 amp Agent Release Solenoid 1 0 amp 0 amp 0.2 amp 0.2 amp Deluge Release Solenoid 0 0 amp 0 amp 0.7 amp 0 amp Aegis Control Panel Capacity (Amperage rating of Power Supply): 4 amp 0.10021 amp[_Total Total System Current Demand: 0.71 am Total amps used in Standby: System Current Demand must not exceed Control Panel Capacity Total amps required for 24 Hours Standby: 2.40504 AH Total Amps required for 5 mm. of alarm: 0.059 AH Total Backup Battery Required: 2.46404 AH Total Backup Battery Provided: 12 AH 20% Derated Battery: 9.6 AH Total Backup Battery Reserved: 7.13596 AH Includes relays activated during pre-alarm conditions. I SIERRA WIRELESS 0 Gauge at 0 Ohms 0 2290 COSMOS CT. 10 Gauge at 1.02 Ohms AEGIS CONTROL PANEL . . . . MS44245 12 Gauge at 1.62 Ohms 6530 Actuator Circuit #1 14 Gauge at 2.60 Ohms 4110 bc Method 16 Gauge at 4.10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 ANECHOIC CHAMBER 20 Gauge at 10.40 Ohms 1020 22 Gauge at 16.40 Ohms 640. 24 Gauge at 26.20 Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop ACTU-1 24 0.2000000 0.2000000 25 14 0.0052 0.0262774 0.1095% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals . 0.200 25 0.02628 0.1095% S U-j 1/13/091:53 PM SIERRA WIRELESS 2290 COSMOS CT. AEGIS CONTROL PANEL Indicating Circuit #2 DC Method Voltage Drop Calculations ANECHOIC CHAMBER 10 Gauge at 1.02 Ohms 12 Gauge at 1.62 Ohms- 6530 14 Gauge at 2.60 Ohms 4110 16 Gauge at 4.10 Ohms 2580 :l8 Gauge at 6.50 Ohms 1620 20 Gauge at 10.40 Ohms 1020 .22 Gauge at 16.40 Ohms 640 24 Gauge.at 26.20Ohms 404. 0 Gauge at 0 Ohms 0 Page 1 of 1 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop B-IND 1 24 0.0670000 0.0670000 5 14 0.0052 0.0017606 0.0073% Total Percentage Amps Conductor Voltage Drop Voltage Drop, 0.0073% Totals 0.067000 5 0.00176 1/13/091:54 PM Page 1 of 1 S SIERRA WIRELESS OGaugeat 0 Ohms 0 2290 COSMOS CT 10 Gauge at 102 Ohms AEGIS CONTROL PANEL 12 Gauge at 1.62 Ohms 6530 Initiating Circuit #1 14 Gauge at 260 Ohms 4110 DC Method 16 Gauge at 4.10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 ANECHOIC CHAMBER 20 Gauge at 1040 Ohms 1020 22 Gauge at 16.40 Ohms 640 24 Gauge at 26.20 Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop P-1 24 0.0000700 0.0001400 5 14 0.0052 0.0000037 0.0000% P-3 24 0.0000700 0.0000700 15 14 0.0052 0.0000055 0.0000% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals 0.000140 20 0.00001 0.0000% S 1/13/091:55 PM Page 1 of 1 SIERRA WIRELESS OGaugeat 0Ohms 0 2290 COSMOS CT 10 Gauge at 102 Ohms AEGIS CONTROL PANEL 12 Gauge at 1 62 Ohms 6530 Initiating Circuit #2 14 Gauge at 260 Ohms 4110 DC Method 16 Gauge at 4.10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 ANECHOIC CHAMBER 20 Gauge at 1040 Ohms 1020 22 Gauge at 16.40 Ohms 640 24 Gauge at 26.20 Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop P-2 24 0.0000700 0.0000700 10 14 0.0052 0.0000037 0.0000% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals 0.000070 10 0.00000 0.0000% S 1/13/091:55 PM /5IrACMO) LD FF.NG I . ON lOP Of Cr1AAf3ER- I / EOL I I --------------------- i/2' MIN. EMT CONDUIT (TIP) . 2--WIRE I4AWG THHN . SOLID COPPER CONDUCTOR . rMY.00 YLNDL..r C r Aç.:j: A'\ • jI fl \L lI L...iJ iflc CI E* fl ("(Tr)(" \L'L-'L. t A'LJ 3 NJL t ACflDT CTAi.ITh iOFO STDLM . . . REFLECTED CEILING PLAN 5CAi /4 AEGISTM Conventional Fire Alarm-Suppression Control Unit r FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending! in-process Suppression focused Control Unit Listed for a Wide Range of Suppression Systems Kidde FM-200, FE13, CO2, 31WTM Novec 1230 Fire Protection Fluid, Argonite, and Halon Clean Agents Kidde INDTM Dry Chemical & WHDRTM Wet Chemical Systems Sprinkler Supervisory Service Deluge, Preaction, Foam, Foam-Water Systems Combination Clean Agent plus Pre-Action System Built-in Class-A and Class-B Circuitry Sophisticated Programmable Notification Appliance Circuits S . Independently Programmable Agent Releasing Circuits with Triple-A Protection DESCRIPTION The Kidde AEGIS is the technologically most advanced Con- ventional Single Hazard Agent Releasing Unit available to the Fire-Alarm Suppression industry today. It combines the high quality, system reliability, and flexibility required by modern commercial, high-tech and industrial applications in an aesthetically pleasing and physically robust package. The AEGIS is well equipped to handle all special hazard extinguishing systems due to the high degree of program- ming flexibility provided and the following full complement of input and output circuits: Three (3) Class A or Class B Detection Circuits Two (2) Class A or Class B SupervisoryCircuits One (1) Class A or Class B Manual Release Circuit One (1) Class A or Class. B Abort Input Circuit Three (3) Class A or Class B Notification Appliance Circuits . Two (2) Class B Agent Release Circuits Four (4) Form-C Relays IWO,KiddeFire Systems A UTC Fire & Security Company Effective: March 2007 84-100 Input and Output 3 Detection Circuits 2 Supervisory Circuits I Manual Release Circuit 1 Abort Input Circuit 3 Notification Appliance Circuits 2 Release Circuits 4 Form-C Relays Programmable Relays Robust Power Supply Elegant User-Interface Simple Configuration Password Protected Digital Release Countdown Battery Voltage and Charging Current Display Extensive Diagnostics Backwards Compatible Improved and Enlarged Cabinet Design 5-Year Warranty DETECTION CIRCUITS The Detection Circuits can support up to 25 Conventional • PD-705x Ionization Smoke, PSD-715x Photoelectric moke, or THD-705x Heat Detectors each as well as Nor- mally Open contact closure type devices. Two circuits are dedicated to the main suppression function and can be pro- grammed to activate the release circuits by either single- shot or cross-zone input. The user-configuration allows automatic release via detection to be delayed from 0 to 60 seconds in 10-second intervals and also allows a choice of which of the two Agent Release Circuits to activate. The third Detection Circuit is programmable for either Watert low or as an independent Detection circuit. When programmed for Waterf low, Notification Appliance Circuits can be programmed as Non-Silenceable as required by certain jurisdictions. SUPERVISORY CIRCUITS The Supervisory Circuits accept Normally Open contact clo- sure type devices such as pressure switches on the agent cylinders or on the water or air pipe network. The system configuration enables the supervisory input to be a partici- pant in the suppression function. For example, low air su- pervisory can be included with detection for release of pre-action systems as required by certain jurisdictions. SUPERVISORY SUPERVISORY 2 1 MANUAL RELEASE AND ABORT CIRCUITS Both the Manual Release and Abort Circuits accept Nor- mally Open contact closure type devices. Activation of the Agent Release Circuits can either be instantaneous or de- layed up to 30 seconds (maximum) upon receipt of Manual Release input. Agent release can be temporarily delayed by activating the Abort Circuit. The Abort input can be pro- grammed for 5 modes of operation. These include the UL 10-second mode, the full-delay mode, the IRI mode, the NYC mode, or the abort can be disabled. Aborts can also be programmed to be applicable for either one or both Agent Release Circuits thereby allowing use with Deluge/Pre-Ac- tion systems. NOTIFICATION APPLIANCE CIRCUITS (NAC) The three Notification Appliance Circuits are rated 1.5 Amps each and accept polarized 24 VDC Notification Appliances. Of the three circuits, NAC1 activates on FirstAlarm, NAC2 in Pre-Release condition and NAC 3 in Releasing condi- tion. Each circuit is driven independently and is user configurable for 60 BPM, 120 BPM, Temporal, or Continu- ous pattern. The MT and NS series appliances provide the option to use silenceable horns and non-silenceable strobes on the same NAC. Multiple NAC circuits (connected to audible .devices only) programmed with the same master code pattern are synchronized, regardless of any differing starting times that preceded their concurrent operation. The NACs configura- tion includes a user-selectable intelligent synchronization featurewhich allows a silenceable horn to be shut off while the strobe continues to flash in synchronized fashion. MANUAL WATERFLOW! ABORT RELEASE DETECTOR 3 DETECTOR 2 TROUBLE RELAY 3 RELAY 2 RELAY I BATT OUT AC IN ( '.. "00 "09 • h bJ'. .' • R232 I "190 @0• TB7 TB6 Q 1,TB5 TB4 TB3 TB2 TBB \ /' TB1 TB9 Oc0.oS AL 0 1 ________________________i Fire Systems Tall O' __ g:g:::: OvoI I 6 sl 0 N Rfl. 0 0 SVSTEMTBL I TB12 Qoai QaaasL ONAC,wL O9TEUSUP I 0 Os.w Qsu*ITBL 0NAC278I OPWTBt I Oo c ,v o AC SUPPLY SELECT SWITCH (S6) / TB19 E7 240 TBI4 TB15 T616 TBI7 TBI8 120 00 TBI3 . rmi DETECTOR I NAC I NAC 2 RELEASE 1 RELEASE 2 AUX NAC3 ARCI ARC2 24VDC Figure 1. Printed Circuit Board (PCB) I BUILT-IN CLASS A AND B CIRCUITRY For the input and NAG circuits, the choice of Class A or Class B supervision is made at site on the board itself by selecting the terminals used for wiring. Neither conversion boards nor additional hardware nor jumper selection is re- quired for this purpose. AGENT RELEASE CIRCUITS (ARC) The two circuits can be programmed for activation by dif- ferent inputs, with independent time delays and abort modes to fire combinations of two of the following releasing de- vices: 1 or 2 Kidde Continuous and Momentary Solenoid Control Heads 1 Kidde Initiator 1 Factory Mutual Group A, B, D, E, F, G, I, J, or K Solenoid In other words, operating in tandem, the two circuits can release: 1 or 2 Control Heads on ARC1 and 1 or 2 Control Heads on ARC2 1 or 2 Control Heads on ARC1 and 1 Initiator on ARC2 or vice-versa 1 or 2 Control Heads on ARC1 and 1 FM Sprinkler Solenoid on ARC2 or vice-versa 1 Initiator on ARC1 and 1 Initiator on ARC2 1 FM Solenoid on ARC1 and 1 FM Solenoid on ARC2 This configurability is useful for those jurisdictions where the gaseous suppression agent is required to be supple- mented with a pre-action system. TRIPLE-R PROTECTION FOR AGENT RELEASING CIRCUITS (ARC) The two ARCs feature a triple failure redundancy safeguard system to protect them from inadvertent activation by the main microprocessor. The Triple-R system requires that in order to activate an ARC, the main microprocessor issues two release commands of opposing polarity via separate channels and that these commands be combined with a third signal from the panel watchdog timer to confirm the microprocessor operation. The Triple-R system ensures that electrical transients or disturbances such as power surges that could interfere with the operation of the main micropro- cessor will not inadvertently activate the connected sup- pression system. The result is a more robust and reliable suppression-focused panel. PROGRAMMABLE RELAYS Of the 4 relays, three are user-programmable for a variety of alarm related conditions and the fourth is a dedicated trouble relay. All relay contacts are rated 3.0 Amps at 30 VDC/120 VAC (resistive). POWER-LIMITED CIRCUITRY All circuits, excluding ARCs are inherently power-limited. Agent Release Circuits, except when firing Initiators, can also be made power-limited by a field located inline releas- ing diode device thereby allowing cost effective installation with all wiring in the same conduit. ROBUST POWER SUPPLY UNIT (PSU) The AEGIS features a universal 120/240 V, 50/60 Hz AC Power Supply Unit with a robust 5.4 Amps of 24 YDC power. Input voltage selection is via a slider switch with no jumper cutting required. The on-board battery charger is able to charge 24 VDC (2.x 12) batteries of capacity up to 68 AH thereby allowing from 24 hours of supervision plus 5 min- utes of alarm to 90 hours of supervision plus 10 minutes of alarm required by some jurisdictions. AUXILIARY POWER SUPPLY Up to 1 Amp of auxiliary power at 24 VDC is available to power external 4-wire devices such as Flame Detectors, AlarmLine modules, Duct Detectors, etc. ELEGANT USER-INTERFACE The user-interlace consists of an array of LED Indicators, Control Switches, a Digital Display, and Buzzer. Over and above the System, Power Supply status, Input circuit Fire and Trouble and Output circuit Trouble LEDs, the AEGIS annunciates its suppression state-of-alarm via three addi- tional Pre-Release, Releasing and Post Release LEDs. Four switches are provided, one each for Acknowledge, Signal Silence, System Reset and Output Disable. The 3-digit dis- play provides a countdown of impending agent release. On command from the user-interlace switches, it also indicates the battery open circuit voltage and charging current. SIMPLE SITE-SPECIFIC CONFIGURATION Accessed via the digital display and user-interlace switches, site-specific configuration is simple, yet detailed and can typically be performed in a matter of minutes. To prevent unauthorized use, the configuration menu is protected by a user-changeable password. Factory technical support can provide assistance with lost or forgotten passwords. Apart from the input voltage selection performed on both the PSU and main board via a slider switch, no other on- board settings or jumper cuttings are required. EXTENSIVE DIAGNOSTICS Also initiated via the digital display and user-interface switches, the troubleshooting function displays diagnostic codes that assist in determining causes of trouble. A com- plete list of diagnostic codes and their meanings ships fac- tory installed on the inside of the enclosure door for easy reference. BACKWARDS COMPATIBILITY Consistent with previous generation Kidde control equip- ent, the AEGIS is listed to be backwards compatible with e full range of Kidde-Fenwal conventional detectors, alarm devices and suppression accessories. Going forward, this will allow older generation panels to be replaced with rela- tive ease. IMPROVED AND ENLARGED CABINET DESIGN The cabinet design allows for easy installation by fitting be- tween the studs of a standard 16 inch studded wall. It is large enough to house two 12 VDC, 12 AH Batteries and provides up to 2 inches (51 mm) of wiring and finger space between the circuit board and the cabinet wall. An optional door design features a factory installed Manual Release and Abort switch for applications with space con- straints. Both switches incorporate guards that prevent their inadvertent activation. Other cabinet options include a flush mounting trim-ring and a dead-front plate required for Canadian applications. TECHNICAL SPECIFICATIONS • Hazards Protected -One • Power Supply I - 120/240 Vac, 50/60 Hz (90 to 264 Vrms, 47 to 63 Hz) AC Main Input - 5.4 Amps at 27 Vdc Output - Battery capacity up to 68 AH @ 24 Vdc - Auxiliary power output rated at 1 Amp at 18.8 - 27.6 Vdc (resettable) Three (3) Detection Circuits - Compatible with up to 25 CPD-705x, PSD-715x, and THD-705x detectors and normally open contact-clo- sure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited - DET 1 and DET 2 used for suppression - DET3/WF configurable for detection or waterflow One (1) Manual Release Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited TECHNICAL SPECIFICATIONS (CONT'D) One (1) Abort Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Two (2) Supervisory Circuits - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Three (3) Notification Appliance Circuits (NACs) - Compatible with polarized 24 VDC Audio-Visual de- vices - Rated at 1.5 Amps each - Configurable as Class A/Style Z or Class B/Style V - Supervised for ground faults, shorts, and open cir- cuits - Power-limited - First Alarm operates NAC 1, Pre-Release operates NAC 2, Releasing operates NAG 3 - Common NAG/ARC output disconnect switch Two (2) Agent Release Circuits - Each compatible with 1 or 2 control heads, or 1 initia- tor, or 1 FM sprinkler solenoid - Circuits electrically capable of simultaneously releas- ing any combination of two of the above devices - Factory configured as Class B/Style Y - Supervised for ground faults and open circuits - Non-power-limited. May be power-limited (except with initiators) and supervised for short circuit using inline releasing resistor-diode device - Common NAC/ARC output disconnect switch Four (4) Relays -3 independently programmable, normally de-energized Form-C - 1 dedicated normally energized Form-C Trouble Re- lay - Relay contacts rated 3 Amps at 30 Vdc/120 Vac (re- sistive) 4 fl, TECHNICAL SPECIFICATIONS (CONT'D) Enclosure - NEMA 1 rated 18 gauge sheet steel with door - Red color - Suitable for wall and surface mounting - Optional Trim Ring - Optional Dead-Front Panel - Optional door with Manual Release and Abort switches - Dimensions: - with Standard Door: 14-1/4 in. W x 5 in. D 19 in. H (362 mm x 127 mm x 483 mm) - with Switch Door 14-1/4 in. W x 6 in. D 19 in. H (362 mm x 152 mm x 483 mm) Environmental Criteria - Indoor/Dry use only - Operating temperature range: 32°F to 120°F (0°C to 49°C) - Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C) Packaging/Shipping - Enclosure, PCB, and PSU packaged in individual car- tons -Accessories shipped include mounting hardware, bat- tery leads, IOM manual on CD-ROM, operating in- struction sheet, and EOL resistor kit - Order inline releasing resistor-diode device (if required) and batteries separately ORDERING INFORMATION DESCRIPTION PART NUMBER Kidde AEGIS Control Unit 84-732001-001 Kidde AEGIS Control Unit with Switches 84-732001-201 In-Line Releasing Diode (10K) Kit 06-220023-001 Trim Ring 76-600000-007 Dead-Front Panel* 06-236725-001 Battery Enclosure 76-1000107001 Kidde AEGIS Conventional Fire Alarm-Suppression Control Unit IOM 06-23671-001 Manual Kidde AEGIS Users CD 06-236727-001 *For Canadian applications, order Control Unit and Dead-Front Panel separately. 0 Kidde is a registered trademark of Kidde-Fenwal, Inc. AEGIS and Gemini are trademarks of Kidde-Fenwal, Inc. FM-200 is a registered trademark of Chemtura. FE-13 is a registered trademark of DuPont. 3M111 NovectM 1230 Fire Protection Fluid is a trademark of 3M. Argonife is a registered trademark of Ginge Kerr. This literature is provided for informational purposes only. KlDDE-FENWAL,INC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 84-100 3/07 ©2007 Kidde-Fenwal Inc. Printed in USA For detailed installation, operation, and configuration infor- mation, refer to the Kidde AEGIS Conventional Fire Alarm- Suppression Conventional Unit Installation, Operation, and Maintenance Manual PIN 06-236716-001. Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 vvww.kiddefiresystems.com List of Agency Listed Compatible Devices APPENDIX B LIST OF AGENCY LISTED COMPATIBLE DEVICES B-i DETECTORS AND BASES Table B-i. Detectors and Bases Device Model Part Number Ionization Smoke Detector CPD-7051 70-510000-001 Ionization Detector Duct Head CPD-7051D 70-510000-060 Advanced Ionization Smoke Detector CPD-7054 70-540000-001 Advanced Ionization Detector Duct Head CPD-7054D 70-540000-002 Photoelectric Smoke Detector PSD-71 55 71-550000-001 Photoelectric Detector Duct Head PSD-7155D 71-550000-060 Photoelectric Smoke Detector PSD-7 155P 71-550000-002 Photoelectric Detector with 135°F Sensor PSD7156 71-560000-001 Advanced Photoelectric Smoke Detector PSD-7157 71-570000-001 Advanced Photoelectric Detector Duct Head PSD-7 157D 71-570000-002 Electronic 135°F Fixed with 15°F ROR Heat Detector THD7052 70-520000-001 Electronic 135°F Fixed Temp Heat Detector THD7053 70-530000-001 2-Wire Detector Base 2W8 70-501000-001 2-Wire Detector Base 2WRLT 70-501000-002 2-Wire Detector Base 2WRB 70-501000-005 2-Wire Relay Module 2WRM 70-500000-004 2-Wire Duct Housing DH-60-2W 70-600000-200 2-Wire Duct Housing with CPD-7051D DH-60-2CPD 70-600000-251 2-Wire Duct Housing with CPD-7054D DH-60-2ACD 70-600000-254 2-Wire Duct Housing with PSD-7155D DH-60-2PSD 70-600000-255 2-Wire Duct Housing with PSD-7157D DH-60-2APD 70-600000-257 P/N 06-236716-001 B-I March 2007 fl I F_ L I List of Agency Listed Compatible Devices Table B-2. Releasing Solenoid Wire Length (ft.) Device I (Mm.) Amps Resistance (Max.) Ohms S 12 On Time AWG .14 AWG 16 AWG 18 AG Max. Number per Circuits Agency 890181 2.4 10 Momentary 300 200 120 - 1 or 2 UL, FM 895630 2.0 12 Momentary 300 200 120 - 1 or 2 UL, FM 899175 2.20 10.8 Momentary 300 200 120 - 1 or 2 UL, FM 48650001 0.24 103 Steady 3000 2000 1200 800 1 or 2 UL, FM 06-118329-001 0.225 108 Steady 3000 2000 1200 800 1 or 2 FM 06-118384-001 0.52 46 Steady 1440 760 480 340 1 or 2 UL 38-509834-001 0.632 38 Steady 1050 550 330 240 1 or 2 UL, FM 38-509837-001 0.4 60 Steady 2300 1460 915 570 1 or 2 UL, FM 81-100000-001 0.44 59 Steady 2300 1460 915 570 1or2 UL,FM 87120099001* 2 12 Momentary 360 240 140 - 1 or 2 UL, FM 87120099012* 2 12 Momentary 360 240 140 - 1 or 2 897494-000 1.5 14.2 Steady 380 240 150 - 1 UL, FM 897494-530 1.5 14.2 Steady 380 240 150 - 1 UL, FM 90487100001* 2 12 Momentary 360 240 140 -- 1 or 2 UL, FM FM Group A 0.458 52 Steady 1440 P 760 480 340 1 FM Group B, D 0.7 34 Steady 940 500 300 220 1 FM FM Group E, G 0.42 57 Steady 1570 760 525 370 1 FM FM Group F Skinner 24 Vdc, 22 Watt Solenoid 7312BN4TNLVNOC322C2 1 FM FM Group I Victaulic 24 Vdc, 8.7 Watts, 364 mA series 753-E Solenoid 1 FM FM Group 3 Viking Model No. 11591, 11592, 11595, and 11596, 24 Vdc, 10 Watts 1 FM FM Group K Viking Model No. 11601, 11602, and 13215, 24 Vdc, 9 Watts 1 FM * Must be used in conjunction with Microswitch P/N 87-120039-001 for momentary operation. Table B-3. Initiator-Based Releasina Devices Device I i (Mm.) Amps I Resistance j (Max.) Ohms I On Time Max. Number per Circuits Agency 83-131025-001 * 3 Momentary 1 * The maximum circuit resistance for this device must be 10 ohms, regardless of the number used. The firing current will be 2.5 Amps. Table B-4. Miscellaneous Devices Device Model Number Supplier/Mfg. eceiving Units for Central Station 5104 Silent Knight March 2007 B-2 P/N 06-236716-001 Suppression System' Abo ft EFFECTIVE FEBRUARY HE FEATURES UL Listed, File # S3743 Flush or Surface Mount Sized for Double Gang Box Large Yellow Push Button Switch One Normally Open Contact DESCRIPTION The KIDDE Abort Station features a large, easy-to-operate abort push button. The momentary type switch is very easy to see due to its highly visible yeiiow color. The abort station stainless steel faceplate is clearly labelled with operation procedures - eliminating indecision and hesitation. The Backbox is painted with red enamel and comes equipped with four 1/2" knockouts. The pre-drilled and tapped mounting tabs allow for easy attachment of the abort station. . TECHNICAL SPECIFICATIONS Electrical Ratings & Specifications: 1.1 amps @ 120 VDC Ambient Temperature: 70°C (158°F) to -20°C (-4°F) Terminals: Captive screws and saddle clamps accept 14 awg to 20 awg wire Includes: Four 6-32 x 1/2" mounting screws Diagrams with Dimensions I 2.85 I PUSH/HOLD 0 SUPPRESSION SYSTEM ABORT KIDDE ORDERING INFORMATION PIN Description Approx. Shipping Wt. 878752-01 Abort Station without Backbox 2 lbs. 878752-02 Abort Station with Backbox 3 lbs. 296105 Backbox This literature is provided for informational purposes only. KIDDE-FENWAL. INC. assumes no responsibility bar the products suitability for a particular application. This product must be properly applied to perform as described herein. It you need more information on this product, or it you have a question, contact KIDDE- PEN WAL INC . Ashland. MA 01721.(508) 881-2000 1-152 2/96 2.5M 51996 Kidde-Fenwal, Inc. Printed in U.S.A. CP 1 lb. LJ KI DDE! Fire Systems KIDDE-FENWAL, INC. 400 MAIN STREET. ASHLAND, MA 01721 TEL: (509) 881-2000 FAX: (508) 881-8920 Manual Pull Stations /or,Kidde Fire Systems Series 3300 A UTC Fire & Security Company Effective: April 2007 K-84-08 FEATURES fl' Exclusive KIDDE® Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Single Pole or Double Pole Keylock for Reset DESCRIPTION The Kidde® Conventional SPST and DPST Series 3300 Manual Pull Stations are high quality, non-coded alarm initiating devices. The Manual Pull Stations are con- structed of heavy die-cast aluminum for long life and use an internal toggle switch for reliable operation. The SPST Manual Pull Station provides an Single Pole, Single Throw switch with screw terminal connections for wiring to the Fire Alarm/Suppression Control Unit. The DPST Manual Pull Station provides a Dual Pole, Sin- gle Throw switch with screw terminal connections. One set of contacts must be wired to the Fire Alarm/Suppre- sion Control Unit and the other may be used for local or remote annunciation. These Manual Pull Stations are designed for quick, effi- cient response by personnel in an emergency, while the double action PUSH/PULL levers prevent accidental operation. This unit should use a break rod as an indica- tor of operation. The Manual Pull Stations can be mounted in an indoor or outdoor weatherproof backbox (Model SBG-32S or Model SGB-32C) or a North American 2-1/2 in. (64 mm) deep 1-gang box. The Manual Pull Station terminal block accepts 14, 16 and 18 AWG wire. FIRE ALARM OR SUPPRESSION RELEASE LABELING The kidde Series 3300 Manual Pull Stations have a unique labeling method which provides the installer the greatest amount of flexibility. Seven labels are shipped with each station: FIRE ALARM • FM-200 RELEASE CO2 RELEASE • FE-13 RELEASE FIRE SYSTEMS • HALON-1301 RELEASE RELEASE NOVEC 1230 RELEASE FM Approved cULus Listed for US and Canada Other domestic approvals in process Surface and Weatherproof Backboxes Backwards compatible mounting with the B-10 and B-Il rv! M1 These permanent, heavy-duty Lexan® self-adhesive labels are die-cut with raised lettering. During installation, the installer simply chooses the appropriate label, removes the protective backing, and places the label into the space on the top of the station. This flexibility allows installations to be customized for each customer, without the expense of having to carry extra inventory. OPERATION The dual action Series 3300 manual stations are oper- ated by simply pushing the PUSH bar inwards, allowing the PULL handle to be grasped in a one-handed motion. The handle is then pulled down as far as it will go. If the optional breakrod is installed, it would break at this point. The handle is now locked in place, and is easily visible from up to 50 feet away. The handle is reset by opening the station with the key and placing the handle in the nor- mal upright position. Place the switch actuator in the down position, insert breakrod into cavity beneath handle ORDERING INFORMATION if applicable), and re-lock the station. SPECIFICATIONS Part Number Description 84-330001 -001 Double Action Manual Pull Station with Station Type: Double Action, Non-coded Switch Type: P/N 84-330001-001: SPST P/N 84-330001-002: DPST Switch rating: 2 Amp @ 240 Vac or 125 Vdc Operating Tempera- -40°F to 150°F (-40°C to 66°C) ture Range: Operating Humidity 0-95% RH Range: Construction: Die-cast metal housing Compatible Electrical Indoor: Sheet metal Model SGB- Boxes: 32S Outdoor: Weatherproof Die-cast Model SGB-32C Shipping Weight: 1.12 lbs. (510 g) SGB-32S INTERIOR SURFACE BACKBOX SDimensions: 4.75 in. H x 3.25 in. W x 2.25 in. D Construction: Steel sheet metal. Conduit: Two knockouts for 1/2 in. conduit connectors, one on top and bottom. Mounting: Mounts to the box with (4) 8/32 screws, which ship with each box. SGB-32C WEATHERPROOF SURFACE BA CKBOX Dimensions: 4.75 in. H x 3.25 in. W x 2.25 in. D Construction: Cast aluminum. Conduit: One threaded opening for 1/2 in. conduit connector. Mounting: Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box. SPST Switch - ships with mounting hardware, 2 keys, 1 break rod, and label set. 84-330001-002 Double Action Manual Pull Station with DPST Switch - ships with mounting hardware, 2 keys, I break rod, and label set. 84-100009-001 SGB-325 Indoor Backbox 84-100009-002 SGB-32C Outdoor Waterproof Backbox 84-100008-002 Pkg. of (12) Breakrods 06-118013-001 Spare Key 06-231866-930 Label Set DIMENSIONS (shown with Fire System Release Label installed) 1.5164 In. (27 mn) 14 In -:: 61 —4 31132 in. ME FIRE SYSTEM Ak SYSTEM RELEASE 4-P RELEASE S Kidde is a registered trademark of Kidde-Fenwal, Inc. FM-200 is a registered trademark of the Greak Lakes chemical Corporation. 3M and Novec are trademarks of 3M. FE-13 is a trademark of DuPont. Lexan is a registered trademark of the General Electric Company. This literature is provided for informational purposes Only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The prod- uct must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. (<-84-08 Rev AA © 2007 Kidde-Fenwal Inc. Printed in USA 'Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com SERIES MT STROBE 11 MT4-115-WH SERIES MT-12124 Wheelock Series MT and MT Strobe Multitone Electronic Appliances Description: The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code- 3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol. The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC andUL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave- rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADA/N FPNUFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable c andela settings at 15/30/75/110cd or with single candela 1575cd strobes. The strobes can be synchronized using Wheelock sync modules or power supplies with built in Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 ®<*> APPROVED E5946 151-92.E 7135-0785:118 (MT4) 7125-0785:155 (MI) 7lflc fl7CQ.lC. /PIflA,O Table 2: Strobe Current Ratings RMS Current (amps) MT-121575 MT-241575 MTWP-2475 MT-24MCW 1575cd 1575cd 180cd 15cd 30cd 75cd 110cd 0.152 0.060 0.094 0.041 0.063 0.109 0.140 0.255 0.090 0.138 0.060 0.092 0.165 0.220 dela 24VDC UL max" NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR qtr TH TO YOU AND/OR OTHERS. eral Notes: obes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for 12VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-12/24, MTWP and MT4 models and listed for outdoor use at -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Current Ratings for Multitone Audible Portion RMS Current (amps) dBA@ lOft (UL Reverberant) dBA@l Oft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 12 and 24 VDC 120 VAC HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output T@ 24 VDC UL max* @ 24 VDC UL max* @ 24 VDC UL max* @ 24 VDC UL max" UL max* UL max" Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 99 93 88 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 92 87 82 75 March Time Horn 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 0.050 0.040 89 84 89 74 99 93 ______ 85 79 ______ Code-3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 99 93 85 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 95 90 79 .75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 99 94 88 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 0.041 89 84 89 75 98 93 85 82 HI/LO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 93 88 82 79 Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. fl' Wiring Diagrams (for all models) MT SIGNAL AUDIBLE SIGNAL AND STROBE AUDIBLE SIGNAL AND STROBE OPERATE OPERATE INDEPENDENTLY IN UNISON. RED AND BLACK SHUNT-WIRES + _________________ ARE SUPPLIED. rROM + To rxt AUME OP PRECEDING TO OR VACP - rmnAP FROM TO NEXT EN:i l LPOWER kACK OR = STROBE AUDIBLE 8R0 Specifications and Ordering Information Model Number Order Code Input Voltage Rated Candela Mounting Options*** Agency Approvals UL MEA CSFM FM BFP MT-12/24-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-12/24-W 5024 12/24 - D,E,F,L,M,O,P,R X X X X X MT241575WFR# 8422 24 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-24MCW-FR 3301 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * * MT-24MCW-FW 3303 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * * MT121575W.FR# 8421 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-121575W-NW 9747 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X * MTWP.2475WFR** 8420 24 180 @ 77°F (25°C) M X X X X * MTWP2475WNW** 9744 24 180 @ 77°F (25°C) M X X X X * MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-WH-VFRO 6224 120 VAC 15 D,E,J,K,N,O,R X X X X X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R X * * * * MT4-12/24-S 7997 12/24 - D,E,J,K,N,O,R X NOTE: **MTwP2475w is Weatherproof and rated for 180 cd @77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. * # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. Pending ## Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. 4ARNlNG: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12124, P84155 MT w/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS,. INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Ititone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #I8AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/75/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM and/or DSM Sync Modules or Wheelock's Power Supplies with Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-12/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. I eBran7hp7venue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2000 MT 06/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I ___ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:189 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Kidde Fire Systems Model AEGIS fire alarm control unit. Automatic, manual, local, central station, protected premises, waterflow, sprinkler supervisory and releasing device services. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label APPROVAL: Listed as a fire alarm, control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation instruction Manual for details. Control unit meets the requirements of the 9th Edition of ANSI/UL 864. This control unit can generate a distinctive three-pulse Temporal Pattern Fire. Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 04-18-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS USTING PROGRAM LISTING SERVICE LISTING No. 7272-1076:187 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector. LISTEE: Kidde-Fenwal, Inc., 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Models PSD-71 57 and PSD-71 57D photoelectric type smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 -36.8 VDC normal, 24 VDC alarm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's 2-WIRE, 2WRLT, 2WRB, 4WRB or MA-001 bases (CSFM Listing No. 7300-1076:116) and separately listed compatible control units. Model PSD-7157 for open area protection between 0 and 300 fpm and Model PSD- 7157D for open area protection between 0 and 4000 fpm. Suitable for releasing device - service when using Models 2WRB, 4WRB bases, and Mechanical Adapter base Model MA- 001. 12-02-2005 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM LISTING SERVICE LISTING No. 7271-1076:186 Page 1 of I CATEGROY: Ionization Smoke Detector LISTEE: Kidde-Fenwal, 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 *FA)( (508) 881-1773 DESIGN: Models CPD-7054 and CPD-7054D ionization type smoke detectors. Refer to Iistee's data sheet for detailed product description and operational considerations. RATING: 10.2-36.8 VDC normal, 24 VDC alarm INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as ionization smoke detectors for use with Models 2-wire, 2WRLT, 2WRB, 4WRB bases and mechanical adapter base MA-001 (CSFM Listing No. 7300-1076:116) and . separately listed compatible control units. Model CPD-7054 for open are protection between 0-300 fpm, Model CPD-7054D for open area protection between 0 and 500 fpm when using base models. Suitable for releasing device service when using Models 2WRB, 4WRB, and Mechanical Adapter base Model MA-001. 12-08-2005 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7300-1076:116 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Kidde-Fenwal Inc., 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Models 2-WIRE, 2WRLT, 2WRB, 4WRB, 4SB, 6SB smoke detector bases, Model ASM-6SB (70-200200-002) addressable signal sounder module with base and Models MA-001 and, MA- 002 smoke detector adapters. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2-36.8 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. . APPROVAL: Models 2-WIRE, 2WRLT, 2WRB, 4WRB are listed as smoke detector bases and Model MA- 001 is listed as a smoke detector adapter for use with Models CPD-7051 (CSFM Listing No. 7271-1076:115), PSD-71 55 or PSD-71 56 (CSFM Listing No. 7272-1076:117) smoke detector heads and separately listed compatible fire alarm control units. Models 2WRLT, 2WRB, 4WRB, 4SB and 6SB are also suitable for duct applications when used with Model RCM500 remote test/LED. Models 2WRB and 4WRB are suitable for releasing device service. Models 4SB, 6SB are listed as smoke detector bases and Model MA-002 is listed as a smoke detector adapter for use with listee's separately listed *compatible fire alarm control units. Model ASM-6SB is listed as a smoke detector base with addressable signal sounder module for use with detector Models PSD-7152 (CSFM Listing No. 7272-1076:142), CPD-7052 (CSFM Listing No. 7271-1076:145) and THD-7252 (CSFM Listing No. 7270-1076:143) smoke detector heads and separately listed compatible fire alarm control units. Rev. 03-21-08 mt This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: ' BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UWA FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:118 Page 1 of I CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Model MT-12/24, MT-115 and MT4-12/24, and MT4-115 multi-tone audible devices followed by R, W, S, or X to indicate package color. Models MT-12, MT4-12, MT-24, MT4-24 multi-tone audible/strobe signals followed by A, B, G, R or W to indicate lens color, followed by S (15 cd), H (15 cd) or M (117 cd) to indicate strobe intensity, and other suffixes to designate orientation, lens lettering and plate color. Models MT-1 15-WH and MT4-1 I 5-WH multi-tone audible/visual devices (Rated 15 cd). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Suffix -12: *8175V0C -24: *1633 VDC -115: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes S and ordinances and in a manner acceptable to the authority having jurisdiction. Models MT series are surface mount and suitable for outdoor with Model lOB back box. Models MT4 series are flush mount and suitable for outdoor with model WBB back box. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed, electrically compatible fire alarm control units. Not suitable for the hearing impaired application. These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 5 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE "7 LISTING No. 7300-1076:120 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland MA 01721-2150 Contact: Terrill Garland (508) 881-2000 *FA)( (508) 881-1773 DESIGN: Models PIN 30-232001-001 front panel w/cutout for audible and P/N 30-232001-002 front panel w/o cutout for audible. These units have a manual release switch and abort switch. Models 878752-01/-02, 30-193000-001/-002 abort stations. Models 296105, 30-193000-003 back boxes. Models 30-322003-003, 84-322003-003 Remote Display Unit Backbox. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, and UL label. APPROVAL: Models 30-232001-001 and 30-232001-002 are listed as control unit accessories when used in conjunction with listees' separately listed fire alarm control units. Models 878752-01/-02, 30-193000-001/-002 abort stations and Models 296105, 30- 193000-003 back boxes are intended for use with listed releasing device control units. Rev. 06-21-2003 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: I JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1076:147 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 *FA)( (508) 881-1773 DESIGN: Models B10 and Bil, 30-195000-002, 30-195000-004, *30..330001..001 *30..330001..002 *84..330001..001 and *84..330001..002 key lock, push bar, noncoded.manual pull stations; Models 30-195000-001 and 30-195000-003 key lock, no push bar, noncoded manual pull stations. Suitable for outdoor use when installed with Model SGB-32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. XLF: 7150-1408:107 *Rev. 04-12-2003 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division VFSchmidt Fire Protection. Co. Inc. 4760 MURPHY CANYON RD. • SAN DIEGO, CA 92123 • (858) 279-6122 • FAX (858) 279-3583 INSPECTIQNRE1ORT Job Name: Contract #: Job Address: Contractor/Owner Name: Con tractor/Owner Address: Insurance Rating Agency: Fire Department: 0 Pre-Action System No. of Systems: Sq. Ft. Smoke Detectors: - Heat Detectors: Accepted By: Date: 0 Alarm Rough-fit Smoke Detectors: Heat Detectors: Pull Stations: Horn/Strobes: Other: Accepted By: Date: o FM-200 System No. of Systems: Functional Test of Devices: Door Fan Test: Accepted By: Date: 0 Oilier System Type of System: Functional Test of Devices: Door Fan Test: Discharge Test: Accepted By: Date: • c1 du5 0/ Le 4uahk?oo S 0