Loading...
HomeMy WebLinkAbout890 PALOMAR AIRPORT RD; KSK 5; FPC2019-0065; PermitPERMIT REPORT eucity of Carlsbad Print Date: 11/03/2021 Permit No: FPC2019-0065 Job Address: 890 PALOMAR AIRPORT RD, # KSK 5, Permit Type: FIRE-Construction Commercial Parcel #: 2110213600 Valuation: $981,155.20 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: CARLSBAD, CA 92011-4443 Work Class: Fixed Extinguishing Syste Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check#: Status: Closed - Finaled Applied: 03/14/2019 Issued: 07/17/2019 Finaled Close Out: 11/21/2019 Inspector: Final Inspection: Project Title: Description: NOTORIOUS SLIDERS KIOSK 5 -NEW HOOD UL-300 SUPPRESSION SYSTEM FPContractor: SAN DIEGO FIRE PROTECTION 1934 BONUS DR SAN DIEGO, CA 92110-1325 (619) 251-7241 FEE AMOUNT FIRE Hood & Duct Extinguishing System Initial Sys $417.00 Total Fees: $417.00 Total Payments To Date: $417.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Fea2OI9 -°(o_ Kitchen Mister -. Restaurant Cooking Area Fire Suppression System I.. a... U.... ..... TECHNICAL MANUAL Components Design Installation Maintenance Recharge Buckeye Fire Equipment BFR-TM 110 Kings Road ULEX 6885 ULC-EX 6885 Kings Mountain, NC 28086 January 1, 2013 0 Chapter 1 Chapter 1 -General Page 1 - 1 Revision 5 General Information Introduction The Buckeye Fire Equipment Kitchen Mister Fire Suppression System is a pre-engineered wet chemical restaurant fire suppression system as defined by the NFPA-17A Standard for Wet Chemical Extinguishing Systems. It is designed to protect commercial restaurant cooking appliances, hoods, and ducts as described in this manual. Installation and maintenance of the Kitchen Mister System must be in compliance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Distributor. CAUTION This technical manual can in no way be considered sufficient to completely understand the proper design, installation, and/or maintenance of the Kitchen Mister System. Buckeye Certified Training is required to become Authorized to perform these procedures. Buckeye Fire Equipment will not be responsible for system(s) designed, installed, or maintained by individuals or companies not trained and Authorized by Buckeye Fire Equipment. How the Kitchen Mister Works The Kitchen Mister System utilizes a potassium based liquid fire extinguishing agent specifically designed for grease laden fires such as those associated with restaurant cooking areas. The Kitchen Mister agent works to suppress commercial kitchen fires in three ways: The agent interrupts the chemical chain reaction causing combustion, thus extinguishing the fire. The agent is discharged in a very fine mist, cooling the fire to below its auto-ignition temperature. The agent reacts with grease to form a foam-like layer commonly called saponification that starves the fire of oxygen, stopping combustion and preventing re-ignition. The system will automatically actuate upon detection of a fire or can be manually actuated by using a remote manual pull station positioned at the point(s) of egress from the hazard area. When the system is actuated, a pre-determined amount of fire extinguishing agent is discharged through the piping network and fixed nozzles to the duct, plenum, and cooking appliances. The agent is discharged as a very fine mist that quickly acts to suppress grease laden fires. System Temperature Limitations The operating temperature range of the Kitchen Mister System is 32°F (0°C.) minimum to 120°F (490C.) maximum. Listings and Approvals The Kitchen Mister Fire Suppression System is Listed and Approved by the following agencies: Underwriters Laboratories, Inc. (Listed to the requirements of UL-300/UL-1254) UL-EX 6885 Underwriters Laboratories of Canada, ULC-EX 6885 Approved by the New York City Fire Department COA# 5550 ISO-9001 Registered Manufacturers Warranty Buckeye Fire Equipment warrants the Kitchen Mister System against defects in material and workmanship for a period of one year from date of shipment to the purchaser under normal use and service. Buckeye Fire Equipment is not responsible for the installation and maintenance of the system. All warranty claims must be filed with Buckeye Fire Equipment within 30 days of the discovery of the defect to be valid. System Installation and Maintenance Requirements Any individual installing or performing maintenance on the Kitchen Mister System MUST be; fully trained and Authorized by Buckeye Fire Equipment, have a complete understanding of this manual in full, and have a complete understanding of all local, state, and federal requirements that may apply. The Buckeye Kitchen Mister System must be installed and maintained in accordance with the NFPA-17A Standard for Wet Chemical Extinguishing Systems, NFPA-96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, this manual, and all applicable local, state, and federal regulations. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 2 - Components Page 2 - 1 Revision 5 Chapter 2 System Components Cylinder Sizes The Buckeye Fire Equipment Kitchen Mister Fire Suppression System has available four (4) cylinder sizes; the Model BFR-5 (5 flow points), Model BFR-10 (10 flow points), Model BFR-15 (15 flow points), and Model BFR-20 (20 flow points). Cylinder sizes are based on the flow point capacity of the cylinder, for example, the BFR-5 is capable of supporting a maximum of five (5) flow points. All cylinders are manufactured, marked, and tested in accordance with DOT 4BW240. Each cylinder is shipped pre-filled with extinguishing agent, and charged with dry nitrogen to a pressure of 195 psig (1344 KPa) @700 F (21° C). Cylinder and valve assembly dimensions are shown in Figure 2-1. Note: Cylinders shall always be stored in an upright position. Figure 2-1. Cylinder and Valve Assembly Dimensions. Model Number A inches (cm) B inches (cm) C inches (cm) D inches (cm) Max. Flow Points Weight lbs. (kg) Mounting Bracket BFR-5 24.8 (63) 16.2 (41) 10 (25) 13.4 (34) 5 42 lbs. (19) MB-1 BFR-10 34.4 (87) 25.8 (66) 10 (25) 23 (58) 10 74 lbs. (33) MB-2 BFR-15 1 44.8 (114) 36.2 (92) 10 (25) 33.4 (85) 15 1 107 lbs. (48) MB-2 BFR-20 1 42.4 (108) 33.8 (86) 12 (31) 31 (79) 20 1 130 lbs. (60) MB-2 BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 0 Systems Releasing Module - SRM The Model SRM Systems Releasing Module is a fully mechanical control head that can be connected directly or remotely to the system valve and is required for system actuation. The Systems Releasing Module will support the following system inputs and outputs: One Fusible Link Detection Line One Gas Valve Line One Remote Pull Station Line Two windows in the front cover of the Model SRM allow for visual verification of the actuation cartridge presence and the status of the puncture pin mechanism. See Figure 2-5. EQUIPMENT 0 SRM 0 1 ACTUATION LEVER AND / ACTUATION CARTRIDGE PUNCTURE PIN VIEWING WINDOW V1EW1NG WINDOW Chapter 2 - Components Page 2 - 3 Revision 5 Model BFR-AC-L is a larger nitrogen cartridge that can actuate up to five agent cylinder (refer to Chapter 4 of this manual for limitations). See Figure 2-6. 5.12 (13 cm) 01.57 Of (4 cm) Model BFR-AC-L 3.70 I (9.4 cm) -- _L.____i_ 01.00 .:1111L111111113 (2.5 cm) Model BFR-AC-S Figure 2-6. Model BFR-AC-S and BFR-AC-L, Nitrogen Actuation Cartridges Mounting Brackets The Model MB-1 Mounting Bracket is used to mount the Model BFR-5 cylinder. See Figure 2-7. Figure 24. Model SRM, Systems Releasing Module The Model SRM can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with SRM and SRM-D) or five (5) agent cylinders when a Model BFR- AC-L Nitrogen Activation Cartridge is installed. Systems Releasing Module - SRM-D The Model SRM-D (Systems Releasing Module —Dual) is exactly the same as the Model SRM except that it supports a second independent fusible link detection line. Nitrogen Actuation Cartridges The Kitchen Mister System can use two types of actuation cartridges for system actuation. Model BFR-AC-S is a small nitrogen cartridge (included with System Releasing Module) that can actuate up to three (3) agent cylinders. BPN: BFR-TM Figure 2-7. Model MB-I, Shown With BFR-5 Cylinder The Model MB-2 Mounting Bracket is used to mount the Model BFR-10, Model BFR-I5, or Model BFR-20 cylinders. See Figure 2-8. LJLEX 6885 ULC-EX 6885 January 1, 2013 Chapter 2 - Components Page 2-4 Revision 5 Figure 2-8. Model M13-2, Shown With BFR-20 Cylinder Remote Mechanical Pull Station The Model RPS-M Remote Mechanical Pull Station provides remote mechanical actuation of the Systems Releasing Module. It is connected to the Systems Releasing Module with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2' (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. A remote pull station is required at the point of egress from the hazard area being protected. See Figure 2-9. Figure 2-9. Model RPS-M, Remote Mechanical Pull Station Mechanical Gas Shutoff Valves A gas shutoff valve is required for all systems protecting gas fueled appliances. A mechanical means of stopping gas flow is provided by the Models BFGV-75 /100 /125 / 150 I 200 / 250 I 300 Gas Shutoff Valves. It is connected to the Systems Releasing Module with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. The valves are rated for natural or LP gas (see Figure 2- 10) and are available in the following sizes: Model Number Valve Size In (cm) Maximum Operating Pressure BFGV-75 %(1.9) 5 psi (.4 bar) BFGV-100 1(2.5) 5 psi .4 bar) BFGV-125 1 1/4 (3.2) 5 psi .4 bar) BFGV-150 1 1/2 (3.8) 5 psi .4 bar) BFGV-200 2(5.1) 5 psi .4 bar) BFGV-250 2 1/2 (6.4) 5 psi .4 bar) BFGV-300 3(7.6) 5 psi (.4 bar) Note: Gas valve size must be no smaller than the size of the gas line it is connected to. 100i I Suva I Figure 2-10. Model BFGV-XXX, Mechanical Gas Valve IN CASE OF FIRE PULL HANDLE HARD ACTU FIRE SE SYSTEM RPS-M 0 ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 1116" 10.16 cm) STAINLESS DETECTION CABLE IBLE 0 Fusible Link Bracket Kit The Model FLB-1 Fusible Link Bracket kit (see Figure 2- II) includes the following: Standard high profile 10" (25 cm) fusible link bracket. Two (2) ½" (1.3 cm) EMT connectors. Two (2) cable crimps. Two (2) '5" hooks. Note: Fusible links must be ordered separately. FUSIBLE LINK BRACKET 112" 0.3 cm) EMT CONNECTOR BLE CRIMP Figure 2-11. Model FLB-1, 10" (25 cm) Fusible Link Bracket Assembly Fusible Link Holder The Model FLH Fusible Link Holder is designed to allow for the use of a continuous fusible link line, thus eliminating the need to cut and crimp each individual fusible link. They can be used either with or without fusible link brackets. They are available in packages of 25 (Model FLH-25). See Figure 2-12. STYLE) Figure 2-12. Model FLH, Fusible Link Holder Fusible Links The Kitchen Mister System uses Globe ML Fusible Links for automatic system activation. See Figure 2-13. Fusible links are designed to separate at specific temperatures, releasing tension from the fusible link Chapter 2 - Components Page 2 - 5 Revision 5 detection line and causing system actuation. Correct fusible link selection is an essential element in the design of any restaurant fire suppression system. After performing a temperature study to determine the maximum ambient temperature at the fusible link location, the correct fusible link should be selected from the following chart: Fusible Link Model Number Max. Ambient Temperature FL-280 225° F. (107° C.) FL-360 300° F. (149° C.) FL-450 375° F. (191° C.) FL-500 430° F. (221° C.) Figure 2-13. Globe ML Fusible Link Buckeye Shielded Cable As an alternative to using conduit and corner pulleys to connect the fusible link system, gas valve, and/or remote pull station to the Systems Releasing Module, the Kitchen Mister System utilizes Buckeye Shielded Cable to perform this function. Buckeye Shielded Cable is 1/16" (0.16 cm) stainless steel cable encased in a protective, flexible conduit. See Figure 2-14. Buckeye Shielded Cable requires no conduit or corner pulleys, as the name implies, provided it is installed in accordance with the guidelines set forth in this manual. Model BFR-SC-100 comes with 105 feet (32 m) of flexible conduit with 210 feet (64 m) of 1/16" (0.16 cm) stainless steel cable inside it. BUCKEYE SHIELDED CABLE 1116" (0.16 cm) STAINLESS STEEL CABLE Figure 2-14. Model 13FR-SC-100, Buckeye Shielded Cable BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Figure 2-18. Model N-SA, Swivel Adaptor cm) NPT MALE THREAD 300 ROTATIO , // 318' (1.0 cm) NPT FEMALE THREAD Chapter 2 - Components Page 2-6 Revision 5 Shielded Cable Interface The Model BFR-SCI Buckeye Shielded Cable Interface is required for connecting Buckeye Shielded Cable to any standard 1/2' (1.3 cm) EMT conduit connector or corner pulley. See Figure 2-15. Figure 2-15. Model BFR-SCI, Shielded Cable Interface Note: A 3/32" (0.2 cm) hex wrench is required to tighten the set screw. Compression Type Corner Pulley When Buckeye Shielded Cable IS NOT used to connect the fusible link system, gas valve, and/or remote pull station to the control head, a corner pulley is required whenever a change in stainless steel cable direction is necessary. The Model CPCT-1 corner pulley is equipped with a compression type fitting that connects to standard 1/2" (1.3 cm) EMT conduit. See Figure 2-16. 0 Model Number Flow Points Band Color N-IHP I Blue N-11-P I Red N-2HP 2 Green N-21-P 2 Yellow N-2W 2 White Note: Details on specific nozzle applications can be found in the Design Section of this manual. 13/16 (0.2 cm) HEX. t TETHERED / BLOW-OFF CAP COLOR ID BAND INTERNAL SCREEN RETAINING RING Figure 2-17. Discharge Nozzle Swivel Nozzle Adaptor The Model N-SA Swivel Adaptor can be used with any discharge nozzle to facilitate the nozzle aiming process. They are chrome plated and allow for a 300 rotation of the nozzle in any direction. See Figure 2-18. Misting type discharge nozzles have been specifically developed for appliance, duct, and plenum applications. Each nozzle has a predetermined flow point value and comes equipped with a blow-off cap to protect the end orifice from blockage. Each nozzle is identified by the model number stamped on the nozzle body and has a unique color band for easy visual identification. See Figure 2-17. Figure 2-16. Model CPCT-1, Compression Type Corner Pulley Discharge Nozzles ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 2 - Components p Page 2-7 Revision 5 Digital Thermometer The Model BFR-DT Digital Thermometer is used to accurately determine the maximum ambient temperature in the plenum in the air stream of each appliance. A thorough temperature survey is necessary for proper fusible link selection. The thermometer comes with a digital readout and remote sensing wand for ease of use. CAUTION A temperature study is required before the installation of any system in order to determine the correct temperature fusible link at each fusible link location. Pipe and Fittings Pipe and fittings must be furnished by the installer. Pipe shall be Schedule 40 black, chrome plated, or stainless steel pipe. Fittings shall be rated 150 LB (68 kg). BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1 2013 Chapter 3 - System Design Page 3 - 1 Revision 5 Chapter 3 System Design OVERVIEW OF SYSTEM DESIGN (127 cm) perimeter and a maximum one side length of 12-1/2" (32 cm) (square) and 16-3/4" (43 cm) The following chapter will cover the proper design of the (rectangular) respectively. It can also protect a round duct with a maximum circumference of 50" (127 cm) Buckeye Fire Equipment Kitchen Mister Fire [16" (41 cm) maximum diameter]. See Figure 3-1 & 3-2. Suppression System. It is divided into three sections: Nozzle Coverages and Placements Piping Limitations Detector Placement Design of the Kitchen Mister System must be in compliance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Dealer. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized. NOZZLE COVERAGE, PLACEMENT, AND AIMING This section will give detailed guidelines for determining nozzle type, positioning, and aim point for appliance, plenum, and duct protection. Ducts - 150" (381 cm) Maximum Perimeter Nozzle: N-2W (2 Flow Point) Coverage: Unlimited length with: 150" (381 cm) Maximum Perimeter with a longest side of 50" (127 cm) for rectangular ducts and 37-1/2" (95 cm) for square ducts or 150" (381 cm) Maximum Circumference [maximum diameter of 47-1/2" (121 cm)] for round ducts. Placement: Centered in duct opening, from 0-6" (0-15 cm) into the duct opening. Aim point: Center of duct. AIM: CENTER OF Duct Protection It is not necessary to shut down or damper the exhaust fan for the system to function properly. It is recommended that the exhaust fan be left on during system discharge to help distribute the extinguishing agent throughout the ductwork. Ducts - 5011 027 cm) Maximum Perimeter NOZZLE PLACEMENT: 1"- 6" (2.5-15 cm) o to 50(0-127cm), N-1 LP] 0"- 6(0-15cm) 0 to 150' (0-381 cm), N-2W] INTO THE DUCT Nozzle: N-1 LP (1 Flow Point) Coverage: Unlimited length with: 50" (127 cm) Maximum Perimeter with a longest side of 16-3/4" (43 cm) for rectangular ducts and 12-1/2" (32 cm) for square ducts or 50" (127 cm) Maximum Circumference (maximum diameter of 16" (41 cm)) for round ducts. Placement: Centered in duct opening, from 1-6" (2.5- 15 cm) into the duct opening. Aim point: Center of duct. The Model N-ILP nozzle is a one flow point nozzle that can protect a square or rectangular duct of unlimited length and changes of direction with a maximum 50" BPN: BFR-TM FOR DUCTS(VERTICAL OR HORIZONTAL) WITHOUT A TRANSITION AIM: CENTER OF N - ENTRANCE TO HORIZONTAL DUCT NOZZLE PLACEMENT: r.... 1/2L 1 6" (25-15 cm) N (Per. 0 t 50" (0-127 cm), N-1LP] 0"- 6"(0-15 cm) [Per. 0 to 150(0-381 cm), N-2W] L INTO THE DUCT TRANSITION FOR DUCTS WITH A VERTICAL TO HORIZONTAL TRANSITION Figure 3-1. Proper Duct Nozzle Placement ULEX 6885 ULC-EX 6885 January 1, 2013 0 Plenum Protection Nozzle: N-1 HP (1 Flow Point) Coverage: Length: 12 feet (3.7 m) max. Width: 4 feet (1.2 m) max. Placement: See Figure 3.7. Aim point: See Figure 3.7. The Model N-IHP nozzle is a one (I) flow point nozzle that can protect a plenum (either single bank or V-bank) of 12 feet (3.7 m) in length and 4 feet (1.2 m) in width per nozzle. Larger plenums must be divided into 12 foot (3.7 m) sections, with each section protected with a separate nozzle. See Figure 3-7. Plenum: V-bank Nozzle Placement The nozzle must be located at the center of the V-bank width and down 1/3 of the vertical height, within 6 inches (15 cm) of the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. Plenum: Single Filter Bank Nozzle Placement The nozzle must be located at a point that is 2" (5.1 cm) from the back edge of the filter and 1/3 of the veitical height of the filter, within 6 inches (15 cm) off the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. 112W 113H 1V SANK 12FT.'' 4(3.7Xm) FT SINGLE SANK Figure 3-7. Model N-IHP Plenum Nozzle Placement and Aiming Note: These examples are typical and do not represent every acceptable nozzle configuration, only a representative sample of them. Designer Note For plenums that exceed 12 feet (3.7 m) in length and therefore require multiple nozzles, it is recommended that the total length be divided into equally sized protection zones and protected accordingly. So a 16 foot (4.9 m) long plenum should be divided into two 8 foot (2.4 m) zones, with a nozzle protecting each, as opposed to a 12 foot (3.7 m) zone and a 4 foot (1.2 m) zone. BPN: BFR-TM Chapter 3 - System Design Page 3 - 3 Revision 5 APPLIANCE PROTECTION Each different appliance must be protected in a specific manner with regard to nozzle selection, placement, and aiming. No deviations from these parameters are allowed and failure to comply completely with these requirements will void the UL Listing of the system and may render the system ineffective. In order to properly understand this section, several key terms need to be defined in advance. DESIGN TERMINOLOGY Nozzle Height: The distance from the tip of the discharge nozzle to the top surface of the appliance (except for woks, in which case the bottom of the wok is used). Hazard Area: All nozzle coverages include the maximum size of the hazard area they can protect. Hazard area is NOT the overall size of the appliance being protected, but rather the actual size of the portion of the appliance used for cooking. Appliances Requiring Multiple Nozzles Some appliances may need to be protected by multiple nozzles because of their size. If the size of an appliance is larger than the approved coverage for that appliance, multiple nozzles must be used. This is accomplished by dividing the hazard area into individual zones that comply with the parameters of the listing for that appliance. In this case, each zone will be protected as an individual appliance with respect to nozzle placement and aiming. RANGE PROTECTION Two (2) Burner Ranae - LOW Proximit Nozzle: N-I LP (1 Flow Point) Coverage: 12" (30.5 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 16" (41 cm) —30" (76 cm) Placement: 3" (7.6 cm) from either edge of appliance, on appliance's long centerline. Aim point: 6" (15 cm) from opposite edge of appliance, on appliance's long centerline. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a range cooking area of 12" (30.5 cm) wide by 24" (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and positioned on the appliance's long centerline within 3" (7.6 cm) of either the front or back edge of the ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design Page 3 - 4 Revision 5 appliance. The nozzle must be aimed at the appliance's long centerline 6" (15 cm) off the opposite edge of the appliance. See Figure 3-8. MAXIMUM HEIGHT 30' (76 cm) NOZZLE PLACEMENT AREA (FRONT OR BACK OF APPLIANCE) MINMUMUBIAMI - AIM P01676" 1K' (41 cm) ' .. Ilk.) FROM RANGE ' OPPOSITE EDGE CENTER NOZZLE LOCATED 3' (7.6 cn,) FROM FRONT OR BACK HAZARD HAZARD 300N: EDGE MAOIMUI(' LENGTH: 12' _- 24(81 AU) Figure 3-8. Low Proximity, 12" (30.5 cm) x 24" (61 cm) Range Model N-1LP Nozzle Four (4) Burner Ranges: 1) Four Burner Rancie— HIGH Proximity Nozzle: N-1 LP (1 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm)-40" (102 cm) Placement: Within 3" (7.6 cm) of the center of appliance. Aim point: Center of appliance. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-9. MAXIMUM HEIGHT (lEG cm) NOZZI l6 cm) PLACE FROM ARE NTER MINIMUMH 30' — "12 )SE.6 cm) 6' CENTER BURR TO LENGTH: BURNER 24- 151 ml WIDT >T~~ 4" H: cm) Figure 3-9. High Proximity, 24" (61 cm) x 24" (61 cm) Range Model N-I LP Nozzle ULEX 6885 ULC-EX 6885 January 1, 2013 2) Four Burner Rancie — LOW Proximity Nozzle: N-2W (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 16" (41 cm) —30" (76 cm) Placement: Center of appliance. Aim point: Center of appliance. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and be centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-10. MAXIMUM HEIGHT 3(Y'(76 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 16(41 cm) ,' RANGE CENTER LENGTH WIDTH: 24" (61 cm) : 24)61 cm) J Figure 3-10. Low Proximity, 24" (61 cm) x 24" (61 cm) Range Model N-2W Nozzle Six (6) Burner Range Nozzle: N-2LP (2 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 35" (89 cm)— 43" (109 cm) Placement: Centered over appliance. Aim point: Center of appliance. The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a range cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located 35" (89 cm) to 43" (109 cm) above the cooking surface and centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-Il. BPN: BFR-TM 11" (28 cm) MAX. MAX. HEIGHr: 24" (81 MN. HEIGHT 18" (41 cm)_1 12 RANGE CENTER MAX. HAZARD LENGTH: 12" (30.5 cm) IF EHELP (6 HIGHER. THEN NOZZLE HEIGHT r MAY INCREASE I PROPORTIONALLY. SHELF MAXINIUM MAY BE EXCEEDED IF NOZZLE (44 Cm) 11P IS PLACED BELOW SHELF HEIGHT. AIM: 6" (16 cm) FROM OPPOSITE EDGE, ON LONG CENTER LINE NOZZLE LOCATED 3" (1.6 cm) FROM FRONT EDGE MAX. HAZARD WIDTH: 24" (61 cm) o Chapter 3 - System Design Page 3 - 5 Revision 5 Model N-ILP Nozzle Figure 3-11. 36" (91 cm) x 24" (61 cm) Range Model N-2LP Nozzle Range I Griddle Combination Appliance Nozzle: N-ILP(1 Flow Point) Coverage: 30" (76 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm) - 40" (102 cm) Placement: Within 3" (7.6 cm) of the center of appliance. Aim point: Center of appliance. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a combination range I griddle with a cooking area of 30" (76 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-11. MAXIMUM HEDHT 40" (102 mc) NOZZLE PLACEMENT FRO AREA CENTER MINIMUM HEIGHT 3 0" (76 en) RANGE-GRIDDLE CENTER BURNER ,MDTH: 12 I(MEX BURNER TO BURNEIUGRJDDLE BURNER TO GRID WI 071.4 GRIDDLE WIDTH: 18 (46 4'73C e) LENGTH: MAX. 30•• ITS en,) Figure 3-12. 30" (76 cm) x 24" (61 cm) Combination Range! Griddle BPN: BFR-TM Protection For Appliances With a Back- shelf The protection of an appliance (such as a range) that has a shelf that can interfere with a nozzle discharge can be accomplished by either using the low proximity coverage for that appliance or placing the nozzle in a position within its stated limitation where the discharge pattern will not be affected. Sample coverages for a range with a back-shelf are shown in Figures 3-13 and 3-14. SHELF WIDTH: NOT TO EXCEED THE CENTERLINE OF THE RANGE UNLESS NOZZLE IS LOCATED UNDER SHELF OR OBSTRUCTION. NOZZLE . MAX. HEIGHT: 11P LOCATED BELOW OR LENEL ". PLACEMEIS WITH THE BO11OM OF THE OBS1RUCT1ON BUT '..CENTER OF MOTTO EXCEED 30" (78 cnn) MIN. HEIGHT 16(41 cm) NOZZLE TIP MJB1 BE AIM: CENTER OF BELOW SHELF OR RANGE DESTRUCTION. 7"9 SUR.El cm) ER WIDTH: BURNERTO BURNER (61 cm) LENGTH 24 (61 cm) Figure 3-13. 24" (61 cm) x 24" (61 cm) Range with Back-shelf Model N-2W Nozzle Figure 3-14. 12" (30.5 cm) x 24" (61 cm) Range with Back-shelf Model N-I LP Nozzle ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design Page 3 - 6 Revision 5 Four Burner Range with a Back-shelf - HIGH Proximity Nozzle: N-2LP (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm)-40" (102 cm) Placement: 6" (15 cm) outside the front edge of the burners within 9" (22.6 cm) from the centerline. Aim point: 6" (15 cm) from the back edge of the burner on the centerline of the appliance. Shelf Height: Minimum of 16' (41 cm) from the top of the appliance. Shelf Width: A maximum of 11" (28 cm). Wok Protection Nozzle: N-1 HP (1 Flow Point) Coverage: 12" (30.5 cm) Min. x 30" (76 cm) Max. Nozzle Ht: 30" (76 cm) - 48" (122 cm) (measured from bottom) Placement: Anywhere over the surface of the appliance. Aim Point: Center of bottom of appliance. MAXIMUM HEIGHT NOZZLE AIMED 48° (122 cm) CENTER OF OK BOTTOM NOZZLE PLACEMENT AREA The Model N-21-P nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface 6" (15 cm) from the front edge of the burners and within 9" (22.5 cm) of the centerline of the appliance. The nozzle must be aimed 6" (15 cm) from the back edge of the burner on the centerline of the appliance. The backshelf shall not be less then 16" (41 cm) from the top of the appliance and extend more then 11(28 cm) over the back edge of the burners. See Figure 3-14a. MAXIMUM WOK DIAMETER: 30' (76 cm) MINIMUM WOK DIAMETER: 12" (30.5 cm) MINIMUM HEIGHT 30" (76 cm) SHELF 191Dm: NOT TO EXCEED 11'(28 cm) MAX. €11941: 40* (102m) NOZZLE PLACEMENT AREA MIN, €IGHT30 (76 cm) AIM: 6'(15 cm) FROM SACK EDGE ON CENTERLINE MAX,K L 9(22.5 cm) BURNER EDGE TO BURNER EDGE: ..(61 cm) NIML91 SHELF I€IGHT l6(4l 0m) (15 CM) > > BURNER EDGE TO BURNER EDGE: 24 (61 511) Figure 3-14b. Wok Protection Model N-IHP Nozzle The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a wok with a minimum diameter of 12" (30.5 cm) up to a maximum diameter of 30" (76 cm). The nozzle must be located 30" (76 cm) to 48" (122 cm) above the bottom of the wok and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-14b. Figure 3-14a. 24" (61 cm) x 24" (61cm) Range with Back-shelf Model N-21-P Nozzle ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3 - 7 Revision 5 Tiltina Brazina Skillet Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25" (51 cm) x 24" (61 cm) per nozzle Nozzle Ht: 24" (61 cm) —45(114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim Point: Center of the protected zone. The Model N.2HP nozzle is a two (2) flow point nozzle that can protect a tilting brazing pan I skillet with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep per nozzle. The nozzle must be located 24" (61 cm) to 45" (114 cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area, See Figure 3-16, MAXIMUM HEIGHT 45(114cm) COVER MUST ,f // NOZZLE NOT INTEFERE j9 / / PLACEMENT WITH NOZZLE \ j' / AREA DISCHARGE MINIMUM HEIGHT 24 61 cm) Figure 3-16. Tilting Skillet! Brazing Pan Model N-2HP Nozzle GRIDDLE PROTECTION 0 Deep Fat Fryer Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25" (51 cm) x 24" (61 cm) Nozzle Ht: 24" (61 cm) - 45" (114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim point: Center of appliance. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a deep fat fryer with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (61 cm) to 45" (114 cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-15. NOZZLE TO BE LOCATED V.flThIN THE PERINETER OP ThE HAZARD MAXIMUM HEIGHT 45" (114 NOZZLE PLACEMENT AREA MINIMUM HEIGHT 24" (91 cm) NOZZLE AIMED CENTER OF HAZARD AREA MAXIMUM WIDTH: 24" (61 cm) MAXIMUM LENGTH: 20,25"(51 Standard riddle: 42"(107 cm) x 30" (76 cm Figure 3-15. 20.25" (cm) x 24" (cm) Deep Fat Fryer Model N-2HP Nozzle Fryers Requiring Multiple Nozzles Fryers that exceed the coverage of a single nozzle can be protected with multiple nozzles. The fryer must be divided into equal sized modules, so that each module does not exceed the maximum coverage allowed for a single nozzle. CAUTION The maximum size fryer that can be modularized is 864 square inches (5,574 sq. cm). BPN: BFR-TM Nozzle: N-1 LP (1 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 24" (61 cm) - 48" (122 cm) Placement: Directly over the edge of the cooking area. Aim Point: 6" (15 cm) from center of appliance in-line with the nozzle. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positioned directly above the edge of the cooking area. The nozzle must be aimed 6" (15 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-17. ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design Page 3 - 8 Revision 5 NOZZLE TO BE LOCATED ON THE PERIMETER OF MAXIMUM HEIGHT THE HAZARD 48 (122 cm) NOZZLE PLACEMENT - AREA MINIMUM HEIGHT 24"(61 cm) NOZZLE E(16-) FROM CENFHP.ZARD LE MAXIMUM -- - 6 mEWTH 16cm)1 LENGTH: 42(107cm) 30" (76 cm) Figure 3-17. Standard Griddle: 42" (107 cm) x 30" (76 cm) Model NA LP Nozzle Large Griddle - 48" (122 cm) x 30" (76 cm) Nozzle: N-1 LP (1 Flow Point) Coverage: 48" (122 cm) x 30" (76 cm) Maximum Nozzle Ht: 30" (76 cm) - 43" (109 cm) Placement: On the centerline of the appliance, 6" (15 cm) off the short edge. Aim Point: 3" (7.6 cm) from center of appliance in-line with the nozzle. MAXIMUM HEIGHT 43" (109 cm) The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a griddle with a maximum cooking area of 48" (122 cm) wide by 30" (76 cm) deep. The nozzle must be located 30" (76 cm) to 43" (109 cm) above the cooking surface, on the centerline of the appliance and 6" (15 cm) off the either short edge. The nozzle must be aimed 3" (7.6 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-18. Extra Larae Griddle - 60" (152 cm) x 30" (76 cm) Nozzle: N-2LP (2 Flow Point) Coverage: 60" (152 cm) x 30" (76 cm) Maximum Nozzle Ht: 24" (61 cm)— 48" (122 cm) Placement: Directly over the edge of the cooking area. Aim Point: 8" (20 cm) from center of appliance in-line with the nozzle. The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area of 60" (152 cm) wide by 30' (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positioned directly above the edge of the cooking area. The nozzle must be aimed 8' (20 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-19. NOZZLE TO BE LOCATED ON MAXIMUM HEIGHT THE PERIMETER OF THE 48(122cm) HAZARD NOZZLE PLACEMENT AREA MINIMUM HEIGHT 24" (61 cm) H NOZZLE PLACEMENT AREA MINIMUM HEIGHT 30" (76 cm) _\.c'(7.6 cm) MAXIMUM WIDTH: (76 cm) MAXIMUM LENGTH: 4(12 8 2 cm) -- FROM CENTER NOZZLE AIMED 8 QHAZARO AREA LENGTH: 60 AXIM> INL WITH NOZZLE MAXIMUM (152 WIDTH: 30(76cm) Figure 3-19. Figure 3-18. Extra Large Griddle: 60" (152 cm) x 30" (76 cm) Large Griddle: 48" (122 cm) x 30" (76 cm) Model N-2LP Nozzle Model N-ILP Nozzle ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3 - 9 Revision 5 of 60" (152 cm) wide by 30" (76 cm) deep. The nozzle must be located 10" (61 cm) to 30" (122 cm) above the cooking surface and positioned 0" to 3" (7.6 cm) outside the short side edge of the cooking area of the griddle. This allows the nozzle to be placed anywhere over the short edge and up to 3" (7.6 cm) outside of the short edge of the appliance. The nozzle must be aimed at the point one-quarter the longest side length (114L) from the griddle short edge, in-line with the nozzle. See Figure 3-19b. MAXIMUM OF 3" (7.6cm) FROM EDGE 7 MAXIMUM HEIGHT 30 (76 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 10)25cm) MAXIMUM LENGTh(L): 60" (152 cm) MAXIMUM 1-1 WIDTH: 30' (76 cm) o Extra Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 2" (5 cm) - 10" (25 cm) Placement: Over any corner, at a 450 angle to the surface. Aim Point: At cooking surface, equal distance from both edges. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle must be located 2" (5 cm) to 10" (25 cm) above any corner of the cooking surface and positioned on the edge of the cooking area of the griddle. The nozzle must be aimed at the point over the cooking surface equal distance from both edges. See Figure 3-19a. MAXIMUM HEIGHT 10(25cm) NOZZLE PLACEMENT AREA MAXIMUM LENGTH(L): 42" (107 cm) MAXIMUM >' \MDTH: 30(78cm) Figure 3-19b. 60" (152 cm) x 30" (76 cm) Griddle Model N-2W Nozzle CHARBROILER PROTECTION Figure 3-19a. 42" (107 cm) x 30" (76 cm) Griddle Model N-2W Nozzle Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 60" (152 cm) x 30" (76 cm) Maximum Nozzle Ht: 10" (25 cm) - 30" (76 cm) Placement: From 0" to 3(7.6 cm) outside the short side edge of the cooking area, Aim Point: One-quarter the length (1/4L) of the longest side, in-line with the nozzle. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area Radiant Charbroiler Nozzle: N-1 HP (1 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: 30" (76 cm) —48" (122 cm) Placement: Anywhere over the surface of the appliance. Aim Point: Center of appliance. The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a radiant charbroiler with a cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 48" (122 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-20. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design 'I) Page 3-10 Revision 5 NOZZLETOBE /.. NOLETOBE OCATED L WITHIN LOCATED WTh THE PERIMETER OF MAXIMUMHEIGHT THE PERIMETER OF THE HAZARD THE THE HAZARD 48' (122 n MAXIMUM HEIGHT 40 (101 cm) __ j... NOZZLE __________ _________________ PLACEMENT - - PLACEMENT NOZZLE AREA AREA MINIMUM HEIGH 30" (78 cm) MINIMUM HEIGHT 24" (61 cm) MAXIMUM WIDTH: T"(61 cm) NOZZLE MED CENTER OF - - . CENTEROF I LENGTH: 38(91 cm) ' '.V WOTH: 24)81 cm) Figure 3-20. Radiant Charbroiler Model N-IHP Nozzle Lava Rock Charbroiler Protection Nozzle: N-2HP (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum Nozzle Ht: 24" (61 cm) - 40" (102 cm) Placement: Anywhere over the surface of the appliance. Aim Point: Center of appliance. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a lava rock charbroiler with a cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (61 cm) to 40" (102 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-21. LENGTH: 24" (61 cn Figure 3-21. Lava Rock Charbroiler Model N-2HP Nozzle Upright Broiler Protection Nozzle: N-1 LP (1 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: Upper corner of broiling chamber. Placement: Positioned in the corner of the front opening of the appliance. Aim Point: Center of cooking grate. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect an upright broiler (salamander broiler) with a cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located in the top front corner of the broiler and aimed at the center of the cooking grate. See Figure 3-22. ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3 - 12 Revision 5 COVERAGE SUMMARY TABLE 'O COVERAGE COLOR FLOW NOZZLE HI. PLACEMENT AIMING APPLICATION Inches (cm) NOZZLE BAND POINT Inches (cm) Inches (cm) Inches (cm) PAGE DUCT, RECTANGLE UP TO 50 (127) PER., MAX N-1LP RED 1 1-6(2.5.15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 SIDE OF 16-3/4 (43) DUCT OPENING DUCT, SQUARE UP TO 50 (127) PER., MAX. SIDE OF 12-1t2 (32) N-ILP RED 1-6 (2.5-15) INTO DUCT OPENING CENTERED IN DUCT CENTER OF DUCT 3-1 DUCT, ROUND UP TO 50 (127) CIRCUM [16 (41) DIA.] N-1LP RED 1 1.6(2.5-15) INTO DUCT OPENING CENTERED IN DUCT CENTER OF DUCT 3-1 DUCT, RECTANGLE UP TO 150 (381) PER.; MAX. SIDE OF 50 (127) N-2W WHITE 2 0-6 (0-15) INTO DUCT OPENING CENTERED IN DUCT CENTER OF DUCT 3-1 DUCT, SQUARE UP TO 150 (381) PER., MAX. SIDE OF 37-1/2 (95) N-2W WHITE 2 0-6 (0-15) INTO DUCT OPENING CENTERED IN DUCT CENTER OF DUCT 3-1 DUCT, ROUND UP TO 150 (381) CIRCUM N.2rN WHITE 2 0-6 (0-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 [47-1/2 (1.21) DIA.) DUCT OPENING PLENUM, SINGLE 12 FT (3.7 m) IN LENGTH; N-IHP BLUE 1 1/3 H FROM TOP; 2(5) IN FROM 0-6 (0-15) FROM END OPPOSITE END OF 3-3 BANK 4 FT (1.2 m) IN WIDTH FILTER BOTTOM PLENUM PLENUM, "V BANK 12 FT (3.7 m) IN LENGTH; N-1HP BLUE 1/3 H FROM TOP; 0-6(0-15) FROM END OPPOSITE END OF 3-3 4FT(1.2m)INW1DTH 1/2W PLENUM RANGE, TWO BURNER 12(30.5) X 24 (61) N-1LP RED 1 16 (41) -30(76) * 3(7.6) FROM FRONT OR 6(15) FROM OPPOSITE EDGE ON 3-3 (Back-shelf) * BACK EDGE ON C'LINE C'LINE RANGE, FOUR 24 (61)X 24 (61) N-1LP RED 1 30(76) -40 (102) WITHIN 3(7.6) OF CENTER OF 3-4 BURNER CENTER APPLIANCE RANGE FOUR BURNER- LOW PROXIMITY 24 (61)X 24 (61) N-2W WHITE 2 16 (41) - 30 (76) * CENTER OF APPLIANCE CENTER OF APPLIANCE 3-4 (BscksheIf)* RANGE, SIX BURNER 36 (91) X 24 (61) N-2LP YELLOW 2 35 (89) - 43 (109) CENTER OF APPLIANCE CENTER OF 3-4 APPLIANCE RANGE/GRIDDLE 30 (76)X 24(61) N-ILP RED 1 30(76)- 40(102) WTHIN 3(7.6) OF CENTER OF 3-5 COMBINATION CENTER APPLIANCE RANGE, FOUR BURNER w/B SHELF - 24 (61)X 24 (61) N-2LP YELLOW 2 30(76) -40 (102) 6(15) OFF FRONT 6(15) from BACK 3-6 HIGH PROXIMITY EDGE EDGE WOK 12(30.5) TO 30 (76) DIA. N-IHP BLUE 1 30(76)- 48 (122) ANYWHERE OVER HAZARD AREA BOTTOM CENTER 3-6 DEEP FAT FRYER, SINGLE VAT 20.25 (51) X 24 (61) N-2HP GREEN 2 24(61)- 45 (114) ANYWHERE OVER CENTER OF 3-7 HAZARD AREA APPLIANCE TILTING SKILLET, BRAISING PAN 20.25(51) X 24 (61) N-2HP GREEN 2 24(61)- 45 (114) ANYWHERE OVER HAZARD AREA CENTER OF APPLIANCE 3-7 GRIDDLE, STANDARD 42 (107) X30 (76) N-1LP RED 1 24(61)- 48 (122) DIRECTLY OVER EDGE 6(15) FROM CENTER, IN-LINE 3-7 OF HAZARD AREA WITH NOZZLE 6 (15) OUTSIDE OF 3(7.6) FROM GRIDDLE, LARGE 48 (122) X 30 (76) N-1LP RED 1 30(76)-43(109) SHORTER EDGE OF CENTER, IN-LINE 3-8 HAZARD AREA ON WITH NOZZLE C'LINE GRIDDLE, EXTRA LARGE 60 (152) X 30 (76) N-2LP YELLOW 2 24(61). 48 (122) DIRECTLY OVER EDGE 8(20) FROM CENTER, IN-LINE 3-8 OF HAZARD AREA WITH NOZZLE GRIDDLE, OVER ANY CORNER AT AT COOKING STANDARD, EXTRA 42 (107) X 30 (76) N-2W WHITE 2 2(5) —10(25) A 450 ANGLE TO SURFACE, EQUAL 3-9 LOW PROXIMITY COOKING SURFACE DISTANCE FROM EDGES GRIDDLE, LOW PROXIMITY 60 (152) X 30 (76) N-2W WHITE 2 10 (25) - 30 (76) 0' to 3(7.6 cm) outside 1/4 Length of the longest side, in-line 3-9 the short side edge with _the _nozzle CHARBROILER, 36(91) X 24 (61) N-1HP BLUE 1 30(76)- 48(122) ANYWHERE OVER CENTER OF 3-9 RADIANT HAZARD AREA APPLIANCE CHARBROILER, LAVA 24 (61)X 24(61) N-2HP GREEN 2 24(61)- 40(102) ANYWHERE OVER CENTER OF 3-10 ROCK HAZARD AREA APPLIANCE CHARBROILER, UPPER CORNER FRONT CORNER OF UPRIGHT 36 (91) X24 (61) N-1LP RED 1 OF BROILING OPENING TO BROILER CENTER OF 3-10 (SALAMANDER) CHAMBER CHAMBER COOKING GRATE * Coverages can be used when a range with a back-shelf or other type of obstruction, as long as the discharge pattern is not affected, ** Cover must not interfere with nozzle discharge. For the High Proximity Back-shelf coverage the shelf shall not exceed more then 11" (28 cm) over the back edge of the burners and be a minimum of 16" (41 cm) from the top of the appliance. ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3-13 Revision 5 PIPING LIMITATIONS This section contains detailed piping limitations that are necessary to design the piping network for The Buckeye Fire Equipment Kitchen Mister Fire Suppression System. Because the system is of the pre-engineered type, maximum and minimum piping parameters have already been established for each cylinder size. No variations to these limitations are allowed under the UL Listing. The maximum and minimum pipe length for each size agent cylinder is based on total internal pipe volume, regardless of the diameter of the pipe used. All piping parameters are based on total system piping and do not make a distinction between branches and supply line piping. Note: Pipe and fittings must be furnished by the installer. Pipe shall be Schedule 40 black, chrome plated, or stainless steel pipe. Fittings shall be rated 150 lb (68 kg). PIPING VOLUME CHART Allowable Pipe Sizes Volume Per foot 3/8 in. (17.1 mm OD) pipe 37.5 mL./ft. (123mLJm) 1/2 in. (21.3 mm OD) pipe 59.8 mL,/ft. (196mLJm) Example: 20 feet (6.1 m) of 3/8" (17.1 mm OD) pipe is equal to 750 mL. of pipe volume [20 ft. (6.1 m) X 37.5 mL./ft. (123mL/m) = 750 mL.). MAXIMUM PIPING PER CYLINDER SIZE Max. Max. Pipe Max. Pipe Cylinder Flow Volume Vol. Between Size Points (mL.) any two (2) Nozzles. (mL.) BFR-5 5 1500 1000 BFR-10 10 2500 2000 BFR-15 15 2800* 2500 BFR-20 20 2800* 2500 * Total volume of 3/8" (17.1 mm 00) piping allowed on the BFR-15 or BFR-20 is 2500 mL. Minimum Piping Requirements Note: Minimum piping requirements ONLY apply when protecting a wok, deep fat fryer, or range. Minimum number of elbows before the closest nozzle protecting a fryer, range, or wok shall be five (5). The minimum piping volume before the closest nozzle protecting a fryer, range, or wok shall not be less then 360 mL. The total system pipe volume shall not be less then 660 mL. for all cylinder sizes. A system shall have a minimum of three (3) flow points. General Piping Requirements All piping must be either 3/8" (17.1 mm OD) or 1/2" (21.3 mm OD). The maximum number of elbows allowed per system are: BFR-5: 20 elbows maximum BFR-10/15/20: 25 elbows maximum The maximum number of elbows between any two nozzles is five (5). The maximum vertical rise of the supply line is 10 feet (3 m), this is either the maximum elevation difference between tank outlet and the highest nozzle or tank outlet and the highest or lowest point in the piping system. The maximum vertical rise of any nozzle above the supply line is 2 feet (0.6 m). No traps are allowed in the piping system. Note: A "trap" is defined as a section of pipe that would allow liquid to accumulate, such as, either a low point in the piping layout or piping that extends past the last discharge point. When different sized piping is used in the same system, the largest diameter pipe must be closest to the cylinder and sizes are to decrease as they reach the nozzle. So piping always runs from larger to smaller diameter. Elbow(s) or swivel adaptors used at the nozzle for aiming DO NOT count toward the total elbows allowed per system or the number of elbows between two (2) nozzles. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design Page 3- 14 Revision 5 0 DETECTOR PLACEMENT Detectors (fusible links) are required to be placed in the air stream of each appliance (one detector per appliance) and in the opening of the exhaust duct(s) of protected ventilation hoods. Detectors shall be located in the plenum area of the ventilation hood behind the filters, which provide protection for the detection system. Exhaust Duct Detector Placement Each exhaust duct must have at least one (1) detector installed. The detector is to be centered in the duct entrance and no more than 12" (30.5 cm) into ductwork. Cooking Appliance Detector Placement Each cooking appliance with a continuous cooking surface area of less than 48" (122 cm) x 48" (122 cm) must be protected by one (1) detector. The detector is to be located over the surface of the appliance and in its air stream when the ventilation system is turned on. Cooking appliances with continuous cooking surfaces larger than 48" (122 cm) x 48" (122 cm) must be protected by multiple detectors, using one detector for every 48" (122 cm) x 48" (122 cm) of continuous cooking area. Exception: If a cooking appliance or appliances are located under a duct opening where a detector has been mounted, it is not necessary to utilize an additional detector as long the duct detector is not more than 12" (30.5 cm) into the duct opening. See Figure 3-26. APPLIANCE APPLIANCE APPLIANCE APPLIANCE COVERED COVERED COVERED COVERED BY BY BY BY DETECTOR DETECTOR DETECTOR DETECTOR A B B C Figure 3-26. Proper Detector Placement Appliances and Duct ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 DEEP FAT FRYER, LG. SINGLE VAT NOZZLE: N2HP PLACEMENT: FLOW PTS.: 2 WITHIN THE COLOR BAND: -,,,-PERIMETER OF GREEN THE HAZARD MAX. HEIGHT: 45" (114) MIN. HEIGHT: 24" (61) AIM: CENTER OF HAZARD AREA Note: Total hazard area can not exed 884 In2 MAX. LEN I 24'(61) (5,574 cm2). 20,25" (51) NOZZLE: N-2HP FLOW PTS.: 2 COLOR BAND: GREEN FOR MIN. & MAX. NOZZLE HEIGHTS, 20SrTION AND AIM POINT REFER TO FRYER NOZZLE PARAMETERS —F COVER MUST NOT INTEFERE WITH NOZZLE DISCHARGE This Section Intentionally Blank HAZARD COVERAGE AREA: 20.25" (51) x 24" (61) Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR-TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. it is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in inches (cm) unless otherwise noted. NOZZLE: N-1LP FLOW PTS.: 1 COLOR BAND: RED ) MAX. oucTç 16"(41 I 6 NOZZLE TIP (15) NOZZLE TIP HOODLENUM - NOZZLE LONGEST SIDE: 16-3/4" (43) PLENUM, SINGLE & 4 F w 1/3H "V" BANK ...1.2M) j/ NOZe BLUE FLO COL VBANK —1/3 X. SINGLE BANK NOZZLE: N-2W FLOW PTS.: 2 COLOR BAND: WHITE 121) DUCT(i MAX. NOZZLE TI!L147-1; /2~" O"6(15) jj NOZZLE _'7" W NOZZLE TIP 112 IN TIP - HOOD/PLENUM LONGEST SIDE: 60"(127) This Section Intentionally Blank RANGE, TWO BURNER CAN BE USED WITH RANGE, FOUR BURNER, (LOW PROXIMITY) BACK-SHELF. SHELF MUSTNOT (HIGH PROXIMITY) NOZZLE: N-1 LP INTEFERE WITH NOZZLE DISCHARGE NOZZLE: N-1LP FLOW PTS.: j MAX. HEIGHT'.,. 40 (102) PLACEMENT FLOW PTS.: I COLOR BAND: WITHIN 3" (7.8) COLOR BAND: RED MIN. HEIGHT: OF CENTER RED OPPOSITE EDGE, 8) 30" (16) MIN.HEIGHT: WI X. HT'50M ON LONG CENTER LINE CENTER OF AIM ' RANGE 6"(15) MAX. B ERTO LENGTH: 12" (305) " . MAX,HAZARD WIDTh: 24" (61) BURNER URN TO LENGTH: BURNER WIDTH PLACEMENT. 3"(7.6) " (61) 24" (61) FROM FRONT OR BACK EDGE, ON LONG CENTER LINE RANGE, SIX BURNER PLACEMENT: RANGEIGRIDDLE COMBINATION CENTER OF RANGE NOZZLE: N-1 LP NOZZLE: N-2LP MAX. HEIGHT: FLOW PTS.: 1 FLOW PTS.: 2 : I43" (109) HAND- HEIGRA MAX COLOR BAND _MIN. RED HT- YELLOW HEIGHT AC 40'(102 ) WITHIN 3" (1.6) MIN. HEIGHT: OF CENTER CENTER COLOR , 30"(78) AIM: CENTER OF OF RANGE GE-GRIDDLE 0 MAXI2" (30.5 0 BURNER TO BURNER 0 BURNER TO MAX. LEN TH: MAX. MDT BURNER 30"(78) 24"(61) WIDTH: 24"(61 RANGE, FOUR BURNER, (LOW PROXIMITY) PLACEMENT: NOZZLE: N-2W CENTER OF RANGE FLOW PTS.: 2 —MAX. HEIGHT: 30"(78) COLOR BAND: WHITE —MIN. EIGHT: 18"(41) AIM: CENTER CM BE USED Wifil OF RANGE BACK.SHELF. SHELF MUST NOT INTEFERE WITH NO22LE DISCHARGE BURNER TO BURNER BURNER LENGTH: 24" (81) TO BURNER 10Th: 24" (61) SHELF W22TItNOT1O RANGE, WITH BACKSHELF, EXCEED I1"(28) (HIGH PROXIMITY) MAX HEIGHT. NOZZLE: N-2LP 40 (102)— FLOW PTS.: 2 NOZZLEPLACEM AFFA COLOR BAND: MIN. HEIGHT:— YELLOW 38" (76) AIM: 6" 1151 MINIMUM SHELF HEIGHT FROM BACK 16" 1411. EDGE ON CENTERLINE (15) MAX R EDGE B" (22.6) 10 BURNER BURNER EDGE 0.(22.5) EDGE: 24" 1611 CAN BE USED TO BURNER EDGE: 24"(61) 6" WITHOUT A 1151 BACK-SHELF BPN: PIS1 0374 REV. 5; DATE: JANUARY 1, 2013 Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR-TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. it Is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in inches (cm) unless otherwise noted. GRIDDLE, STANDARD (42"(107) MAX.1 NOZZLE; N-ILP FLOW PTS.: I COLOR BAND: RED PLACEMENT: ON METER OF THE HAZARD AIM:8(I5) FROM CENTE -48- (122) OF HAZARD AREA. INLINE -MIN. HEIGHT.' WITH NOZZLE 24(81) 4(1;07)A OF T H MAX. HEIGHT: M LENGTH:X. DTH: 4 (76) MAZIMUM OF GRIDDLE, LOW 3m (7.6) / PROXIMITY MAN NOZZLE: N-2W 30 FLOWPTS.:2 NoZ COLOR BAND: WHITE PLACIMIENr AIGE M HIHEIG MAIGMUM 114 UM wimiVix B.(16) RADIANT CHARBROILER NOZZLE: N-IHP PLACEMENT* WITHIN FLOW PTS.: 1 ' THE PERIMETEROF COLOR BAND: THE HAZARD BLUE "> HEIGHT 48' (122) AIM: CENTER MIN OF HAZARD NT AREA LENGTH: WIDTH: 36"(91) 24'(81) GRIDDLE LARGE 148" (122) MAX.] NOZZLE: N-ILP FLOW PTS,: 1 PLACEMENT: 6' COLOR BAND: RED (15) OFF GRIDDLE I EDGE, ON LONG I CENTER LINE l MAX. HEIGHT: 43' _L&. I?III(" (109 CENTER.IN LINE WITH HEIGHT: NOMEMIN. MATH: LENG MAX WIDTH: 4(122) GRIDDLE, EXTRA MMIHUM HEIGHT NOZZLE: N-2W FLOW PTS.: ZL NOZZLE PLACEMENT COLOR BAND: SHALl. BE ABOVE MINIMUM ANY CORNER WHITE HEIGHT <$XIMITY MAZIMUM MAXIMUM LENGTH(I4 WIDTh 42' (107) 20' (75) LAVA ROCK CHARBROLER NOZZLE: N-2HP FLOW PTS.: 2 COLOR BAND: PLACEMENT: WITHIN THE GREEN 0 PERIMETER OF ThE HAZARD MAX.HEIGHT EN. HE 10 NT: AIM: CEN HALAR 24'(81) GRIDDLE, X-LARGE [60" (152) MAX.] NOZZLE: N-2LP PLACEMENT: ON ER COLOR BAND OFRD YELLOW MAX. FLOW PTS.: 2 0 2C HEIGHT: AIM: 8'(20)48'(122) OF HAZARD FROM CENTER IN AREA INUNE EIGHT: NTH NOZZLE (61) MAX LENGTH: 60' WOK NOZZLE: N-1HP AIM: AT CENTER OF MAX OKBOTEOM HEIGHT: FLOW 45'(122) 1 COLOR WITHIN THE PERIMETER OF THE WOK DIA.: 30' WOK DIA.: 12 , BROILER AND UPRIGHT BROILER NOZZLE: N-ILP FLOW PTS.: I COLOR BAND: RED AIM CENTER OF COOKING ti GRATE PLACEMENT: TOP CORNER OF FRONT OPENING LENGTH: 35"(91) MAX WIDT MAX. MAXIMUM PIPING PER CYLINDER SIZE Piping Limitations: >3/8(17.1 mm 00) or 112"(21.3 mmi 00) Sch. 40 black pipe. > pipe sized largest to smallest only. > No "traps" allowed. Max. number of elbows between any (2) nozzles: 5. 'Max. vertical flee: 10 feet (3m). > Max. vertical rise from nozzle to supply line: 2 feet (06 m). Minimum Piping Requirements (Wok, Range, & DFF only): > Mm. if of elbows before closest nozzle: 5. Mm. pipe volume before closest nozzle: so mL. >Total system pipe volume: 600 mL. > Minimum number of flow points in system: 3. CYLINDER SIZE MAX. FLOW POINTS MAX. PIPE VOLUME ALLOWED (mL) MAX. PIPE VOL.BETWEEN ANY TWO NOZZLES (mL) MM, if OF ELBOWS BFR-5 5 1500 1000 20 BFR10 10 2500 2000 25 BFR-15 15 2800' 2500 2 BFR-20 20 2800' 2500 25 i otsi voiuma UT IO piping BIIOWOD IS ZOIJU mL. CONDUIT AND BUCKEYE SHIELDED CABLE (BSC) LIMITATIONS r PIPE SIZE (SCH. 40) PIPE VOLUME FUNCTION MAX. CONDUIT LENGTH FT (M) MAXIMUM NUMBER OF CORNER PULLEYS MAX. LENGTH OF BSC FT (M) MAXIMUM NUMBER OF BENDS IN THEBSC (MIN. BEND RADIUS) BSC TO CONDUIT TRANSITIONS (NUMBEROF BSCI) MAXIMUM NUMBER OF FUSIBLE LINKSAND HOLDERS 3/8 In. (17.1 mm OD) pipe I 37.5 mUtt. (123mLJm) 1/2 In. (21.3 mm OD) pipe I 59.8 mL,Ift. (196m1Jm) REMOTE CYLINDER ACTUATION LIMITATIONS ACTUATION CARTRIDGE PART NUMBER NUMBER OF CYLINDER(S) THAT CAN BE ACTUATED BETWEEN MAX. LENGTH OF 1/4' (0.6) OD COPPER TUBING MAX. LENGTH OF TUBING CYLINDERS FUSIBLE LINK LINE; CONDUIT & BSC 25(7.6) 8 35 (10.7) 6 19"(23)] 1 8 10 GAS VALVE LINE; CONDUIT & BSC 25(7.8) 8 35 (10.7) 8 [9" (23)] 8 NA RPS-M LINE; CONDUIT& BSC 25(7.8) 8 35(10.7) 8 [9" (23)] 6 NA FUSIBLE LINK LINE; CONDUIT ONLY 150 (45.7) 35 NA NA NA 20 GAS VALVE LINE; CONDUIT ONLY 150(45.7) 35 NA NA NA NA BFR-AC-S 1.3 15 FEET (4.6 m) 3 FEET (0.9 m) RPS-M LINE; CONDUIT ONLY 150 (45.7) 35 NA NA NA NA FUSIBLE LINK LINE; BSC ONLY NA NA 35(10.7) 8 [9" (23)] 6 10 BFR-AC-L 1-5 25 FEETT (7.6 m) 3 FEET I (0.9 m) GAS VALVE LINE; BSC ONLY NA NA 1 35 (10.7) 6[9' (23)] 6 NA RPS-M LINE; BSC ONLY NA NA 35 (10.7) 6 [9" (23)] 6 NA > BSC CAN NOT be coiled or looped when installed. BPN: P1S10374 REV. 5 DATE: JANUARY 1, 2013 o Quilgg o 1fl a a E-mail* bfecbuckeyef.coni • Internet: httpJIwww.buckeyet.con/ftre September 17, 2008 Subject: Gyro Cooker Protection To: Authorized Buckeye Kitchen MisterTM Distributors To Whom It May Concern: Underwriters' Laboratories Inc. (UL) does not currently have a testing procedure for gyro cookers; however, these appliances may require protection based on the judgment of the local authority having jurisdiction. When protection is required, gyro cookers are protected in the same manner as an upright broiler (see page 3-8 and 3-9 of the Buckeye Technical Manual, PIN BFR-TM). One model N-1LP nozzle is used to protect a gyro cooker with a maximum cooking area of 36" wide by 24" deep. For this application, the nozzle is to be located in the top corner of the appliance and aimed at the bottom center. If the appliance is equipped with doors, the nozzle must be positioned in such a manner that the doors do not interfere with the discharge of the nozzle. If you have any additional questions please do not hesitate to contact me. Sincerely, 6/ILcf Bruce Euler Pre-engineered Systems Manager Buckeye Fire Equipment company ISO 9001 Registered E-mail:bfecbuckeyef.com Website: www.buckeyefire.com June 29, 2017 Mr. James Wiseman San Diego Fire Protection Subject: Response to your inquiry regarding the applicable NFPA-96 requirements for replacement air shut-down upon fire extinguishing system activation. Dear Mr. Wiseman, The NFPA-96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, Section 8.3.2, is the binding code requirement regarding replacement air (makeup air) shut-down during system activation. The Kitchen Mister System, and any other restaurant area fire suppression system for that matter, must comply with this requirement. It states: "8.3.2 When the fire-extinguishing system activates, makeup air supplied internally to the hood shall be shut off." The term "internally", as sited in this section, is intended to specify that only makeup air that is supplied directly into the hood itself (i.e., into the catch basin of the hood) is required to be shut off. Any makeup air supplied outside of the hood itself is not required to be shut off. I hope this information helps clarify the issue. I should point out that I am on the NFPA-96 Technical Committee and have a very good working knowledge of both the current document and its history. Kind Regards, kt-L. tv_ William Vegso Buckeye Fire Equipment Buckeye Fire Equipment Company ISO 9001-2008 Registered I nuttnhmanc, 3Ebucatitrnzt1 'iIreiif Hours IEarne: 09/08/2020 - 3eñn Bober Iresient ucbege 3irt lquipment (iIumpzn