HomeMy WebLinkAbout2560 ORION WAY; ; FPC2020-0181; PermitPERMIT REPORT (70ty of Carlsbad Print Date: 03/09/2021 Job Address: 2560 ORION WAY, CARLSBAD, CA 92010-7240 Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: 2090502600 Track #: Valuation: $1,656,546.67 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: CARLSBAD SAFTEY CENTER - BACKFLOW REPLACEMENT Permit No: FPC2020-0181 Status: Closed - Finaled Applied: 10/15/2020 Issued: 11/02/2020 Finaled Close Out: 03/09/2021 Inspector: Final Inspection: Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $756.00 Total Payments To Date: $756.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov Hydraulic calculations using HydraCALC COSCO FIRE PROTECTION 4990 GREENCRAIG LANE SAN DIEGO, CA 92123 1-858-444-2000 Job Name : CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Drawing : FP-1 Location : 2560 ORION WAY Remote Area BOR Contract : 10.CA_5506 Data File : SAFETY CENTER BOR CALC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 COSCO FIRE PROTECTION CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC HYDRAULIC CALCULATIONS for Project name: CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Location: 2560 ORION WAY Drawing no: FP-1 Date: 9-14-2020 Design Remote area number: BOR Remote area location: RISER ROOM Occupancy classification: OFFICE Density: .10 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: N/A - SqFt Type of sprinklers calculated: N/A No. of sprinklers calculated: 53 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 374.63 - GPM Type of system: OVERHEAD WET PIPE Volume of dry orpreaction system: N/A - Gal Water supply information Date: 9-30-2020 Location: ORION CIR. Source: H20625 Name of contractor: COSCO FIRE PROTECTION Address: 4990 GREENCRAIG LANE I I SAN DIEGO, CA 92123 Phone number: 1-858-444-2000 Name of designer: MJ LOVELY Authority having jurisdiction: CARLSBAD FIRE Notes: (Include peaking information or gridded systems here.) Page 1 Date 9-14-2020 @ 72-Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C COSCO FIRE PROTECTION V Page 2 CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Date 9-14-2020 City Water Suppjy: Demand: Cl - Static Pressure : 80 Dl - Elevation : 0.217 C2 - Residual Pressure: 72 D2 - System Flow : 374.6 C2 - Residual Flow : 1565 D2 - System Pressure : 10.426 Hose ( Demand) : 250 D3 - System Demand : 624.6 Safety Margin : 68.111 150 140 130 p120 R11° E10° Q90 - Cl ________ _________ ___________ ____________ 80 2 u 70 R6° E5° 40 30 20 D2 10 201400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO FIRE PROTECTION Page 3 CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Date 9-14-2020 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 1¼ 2 2Y2 3 3¼ 4 5 6 8 10 12 14 16 18 20 24 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zig Wilkins 375DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations: Hazen-Williams COSCO FIRE PROTECTION Page 5 CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Date 9-14-2020 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pt/Ft Eqv. Ln. Total P1 Pn BOR 374.60 6.16 3L 38.734 10.000 0.0 Qa = 374.63 to 140.0 0.0 38.734 1.949 UGI 374.6 0.0040 0.0 48.734 0.194 Vel = 4.03 UG1 0.0 6.09 0.0 37.000 2.143 to 150.0 0.0 0.0 0.0 UG2 374.6 0.0037 0.0 37.000 0.138 VeI= 4.13 UG2 0.0 6.16 L 12.911 7.500 2.281 to 140.0 0.0 12.911 -3.032 BF1 374.6 0.0040 0.0 20.411 0.081 Vel = 4.03 BFI 0.0 6.16 / Zig 0.0 2.500 -0.670 to 140.0 0.0 0.0 9.470 * * Fixed Loss = 947 BF2 374.6 0.0044 0.0 2.500 0.011 Vel = 4.03 BF2 0.0 6.16 L 12.911 7.500 8.811 to 140.0 0.0 12.911 3.032 UG3 374.6 0.0040 0.0 20.411 0.081 Vel = 4.03 UG3 0.0 6.09 G 4.625 12.500 11.924 to 150.0 T 46.249 50.874 -1.732 TEST 374.6 0.0037 0.0 63.374 0.234 Vel = 4.13 250.00 Qa = 250.00 624.60 10.426 K Factor = 193.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 4 CARLSBAD SAFETY CENTER BACKFLOW - BOR CALC Date 9-14-2020 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. BOR 0.5 0.0 na 374.63 UGI -4.0 2.14 na UG2 4.0 2.28 na BF1 3.0 -0.67 na BF2 3.0 8.81 na UG3 -4.0 11.92 na TEST 0.0 10.43 na 250.0 The maximum velocity is 4.13 and it occurs in the pipe between nodes UG1 and UG2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NSF/ANSI 61 Model 475DA/475DAV Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 475DA/475DAV shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance ASSE® Listed 1047 (4" thru 8") AWWA Compliant C550 UL® Classified (4" thru 10") C-UL® Classified (4" thru 10") FM® Approved (4" thru 8") NYC MEA 170-02-M VOL 2 (4" thru 8") Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (4" thru 8") Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLM Springs Stainless Steel, 300 series MODEL 475DAV MODEL 475DA Options (Suffixes can be combined) with OS & Y gate valves (standard) LI L - less shut-off valves (grooved body connections) LM - less water meter - with gpm meter (standard) - with cu ft/min meter J V - vertical flow up configuration Li G - with groove end gate valves FG - with flanged inlet gate connection and grooved outlet gate connection BG - with grooved end butterfly valves with integral supervisory switches E BF - with flanged end butterfly valves with integral supervisory switches P1 - with post indicator gate valve LI —509 - with AWWA C509 gate valves Features 4", 6", 8", 10" .Sizes: Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI 1316.1 Class 125 Relief Valve discharge port: 2 1/2"- 6" -2.75 sq. in. 8"- 10" - 3.69 sq. in. Dimensions & Weights (do not include pkg.) WEIGHT I I MODELS LESS WITH WITH WITH BFLY I WITH BFLY I 4750A & SHUTOFF OS&Y OS&Y VALVES VALVES I 475DAV VALVES GATES GATES (GXF) (GXG) I SIZE (GXF) (GXG) I lbs.I kg lbs. I kg lbs. kg lbs. I kg lbs. I kg I 4' 1131 51 303 137 279 127 183 83 161 73 I 6" 1871 85 487 221 465 211 291 132 261 I 118 I 8" 421 191 897 407 843 382 611 277 565 I 256 I 10' 439 199 1113 505 1055 479 713 323 655 I 297 I Accessories Ej Air gap (see spec sheet BF-AG) Ej Repair kit (rubber only) LIJ Thermal expansion tank (Model XT) Valve setter (Model FLS or MJS or MJFS) Gate valve tamper switch (OSY-40) QT-SET Quick Test Fitting Set DIMENSIONS (approximate) B B B C C MODELS 475DA & A WITH GATE WITH BFLY LESS GATE OS&Y WITH BFLY 0 475DAV VALVES VALVES VALVES PEN CLOSED VALVES SIZE in. mm in. mm in. mm in. mm in. mm in. mm in. I mm in. I mm 4" 475DA 185/16 465 30 '762 273/4 705 21 583 223/4 578 181/4 464 9 229 8 203 4" 475DAV 187/8 479 361/2 927 32 813 1 181/2 470 1 223/4 '578 181/4 464 9 229 8 203 6" 475DA 1811/16 475 351/2 902 321/8 816 25 635 1 301/8 '•765 233/4 603 1 'TTh 260 10 254 6" 475DAV 21 533 1 42 1067 351/4 855 21 533 1 301/8 765 233/4 603 101/4 260 10 254 8" 475DA 29 737 46 1168 429/16 '19 347/16 875 37314 959 291/4 743 _12 13 330 8" 475DAV 305/16 770 531/2 1359 469/16 1183 305/16 770 373/ 959 291/4 743 12 305 13 330 10" 475DA 29 771 471/2 1207 447/16 1129 347/16 875 453/4 1162 353/8 899 13 330 13 330 10" 475DAV 1 305/16 770 1 561/2 1435 505/16 127830 5/16 770 1 453/4 TT 353/8 899 13 330 13 330 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn•com Rev. G Date: 3/20 Document No. BF.475DA&V Product No. Model 4750A & 475DAV Page 1 of 2 138 ' 0. (150mm) 103 69 w 34 U) w 0 0 1600 189.3 iia a 103 U) 0 -J 3000 Flow Characteristics ORated Flow (established by approval agencies) ("UL curve) 100.9 0 400 800 1200 FLOW RATES (GPM) MODEL 475DA & 475DAV 8" & 10" (STANDARD & METRIC) 0.0 63.1 FLOW RATES (us) 126.2 20 '200mml 15 0 10 w CL 0 0 1000 2000 FLOW RATES (GPM) fl 0.0 0 20 U) 0. 15 U) 0 —ii w - - - U) 5 U) W - MODEL 475DA & 475DAV 4" & 6" (STANDARD & METRIC) FLOW RATES (us) 25.2 50.5 75.7 Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of 0 the unit can be submerged. Capacitythru Schedule 40Pipe(GPM) Pipesize 5ft/sec 7.5ft/sec 10ft/sec 15ft/sec 2 1/2' 75 112 149 224 3' 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8' 780 1169 1559 2339 10" 1229 1843 2458 3687 MODEL SIZE in. I mm DIMENSIONS (approximate) Al SETTER END TO END FLS in. I mm Al SETTER END TOEND MJS in. I mm 4 100131 5/161 795 295/16 745 6 150 343/4 884 323/4 832 8 200 47 1194 445/8 1133 10 250 51 1295 47 1194 ZURN WIU VERTICAL INSTALLATION DIRECTION OF FLOW OUTDOOR INSTALLATION Specifications The Reduced Pressure Detector Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1047, and supplied with full port OS & Y gate valves. The main body and access covers shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The Reduced Pressure Detector Assembly shall be a ZURN WILKINS Model 475DA or 475DAV. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 655-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 /\1i' POTTER ROEMER RRE PR 0. Member of Morris Group InternationaIm CONNECTIONS (FDC) EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE Model/Series No. 5710-5734 SERIES MODEL DIMENSIONS TWO-WAY WITH SINGLE CLAPPER UL Listed File #EX4078 MODEL 5710-5715 Model #S201 B tWPROVEU TWO-WAY WITH DOUBLE CLAPPER Outlet Approvals Outlet Approvals Size A #EX3314 B C D Back Model No. c®us LISTED #B(3314 Angle Model No. c®us LISTED 5721 Yes 5731 Yes 4x2-1/2x2-1/2 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 71/4e MODEL 5721 - 5734 S UL Listed File #EX3314 Model #A105 Call Potter Roamer Fire Pro for current listings and approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roemer- - FIRE EQUIPMENT __ MANUFACTURERS' Ot'IFSA POTTER ROEMER/FIRE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of void or - ASS OCIATION P.O. Box 3527 New York (800) 526-4592 superceded data. @ Copyright Potter Roamer. Fire Pro, City of Industry, CA Chicago (800) 547-3473 Member of Morris Group International " Please visit potterroemer.com for most current specifications. - - no E 9 'GsP 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866)961-3473 800-366-3473 Dallas (866) 644-3473 5710-5734 SERIES Date: 12/11/18 NFPA 626-855-4890 www.potterroemer.com /\\\\N n,9E POTTER ROEMER PRO. Member of Morris Group lnternafionalre CONNECTIONS (FDC) EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE Model/Series No. 5710-5734 SERIES SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER, 300 PSI RATED Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4" x 2-1/2" x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER, 175 PSI RATED Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. C®US UL File #EX4078 LISTED Model #S201B APPROVED MODEL 5710 (Shown) MODEL SELECTION TWO-WAY WITH SINGLE CLAPPER Li 5710 Back Outlet (UL Listed) 4 FM IJ 5715 Angle Outlet (UL Listed) 4 FM Do- TWO-WAY WITH DOUBLE CLAPPER Li 5721 Back Outlet EJ 5722 Back Outlet 5723 Back Outlet Li 5724 Back Outlet 5731 Angle Outlet lJ 5732 Angle Outlet Li 5733 Angle Outlet Li 5734 Angle Outlet PRODUCT OPTIONS FINISHES: IJ -B Polished Brass Li -C Rough Chrome Plated Body U -D Polished Chrome Plated THREADS: Li N.S.T. Li Other_ LETTERING AVAILABLE: Li AUTO. SPKR. IJ STANDPIPE Note: Refer to Model Dimensional Chart for UL & FM Listing Call Potter Roamer- Fire Pro for current listings and POTTER ROEMER/FIRE PRO approvals. Dimensions are subject to manufacturer's tolem nce and may change without notice. Potter Roamer- 7 FIRE EQUIPMENT MANUFACTURERS OtJFSA ASSOCIATION Headquarters: Also in: Fire Pro assumes no responsibility for use of void or - - P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roamer- Fire Pro, . City of Industry, CA Chicago (800) 547.3473 Member of Morris Group International " Please visit potterroemer.com for most current specifications. 91744 U.S.A. Atlanta (800) 762-0542 r NAFDf E NFPAn10 A Los Angeles Area Miami (866) 961-3473 800-366-3473 Dallas (866) 644-3473 51105134 SERIES Date: 12/11/18 626-855-4890 www.potterroemer.com WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov T.. drYLER UNION® DUAL PURPOSE CUTTING-IN SLEEVE MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment MJ x FE Cutting-In Sleeve with Dual Purpose Accessories Size Dimensions For Pipe Size L L1 T Shipping Wt. Assembled 4 4.80-5.00 O.D. 10 9.5 .35 33 6 6.90-7.10 O.D. 10 9.5 .37 50 8 9.05-9.30 O.D. 10 9.5 .39 67 10 11.10-11.400.D. 10 9.5 .41 122 12 13.20-13.50 O.D. 10 9.5 .43 157 Flanged ends are faced and drilled per ANSI/AWWA C110/A21.10. Mechanical ioint ends are designed to receive both stan- dard and oversize gray or ductile iron pipe as shown above. MJ x FE Flange TYPICAL CUTTING-IN SLEEVE INSTALLATIONS VALVE _______________ INSTALLATIONS JLTiffiiii._ *RETAINER GLAND ASSEMBLY Pipe Wall Thickness: Sizes 3-12" are recommended for ductile iron pipe class 50 thru 56. Sizes 14" thru 24" are recommended for ductile iron pipe class 53 thru 56. DUCTILE IRON RETAINER GLANDS Mechanical Joint Retainer Glands are designed to provide a method for restrain- ing mechanical joint pipe and fittings and other standardized mechanical loints against possible joint separation, rupture or blow-out caused by internal water pres- sure. The set screws are square-headed with Type C knurled cup points, and are shipped already assembled in the Glands. They are manufactured of 4140 grade alloy steel, and are heat treated to a Rock- wall "C" 45/53 case hardness. Tee-head bolts and gaskets are not included, but may be ordered separately. Recommend- ed torque for set screws is 75 foot pounds, and set screws on opposite sides of the glands should be tightened alternately. Tee-head bolt hole size and spac- ing are equal to Mi Glands as shown in AWWA C-i 11. Standard mechanical Joint gaskets as shown in C- i 11 should be used. i.i 1 Ns ,flststsjstrts,stst2rfl'sjflrrsflrfl A See Installations Instructions........................................................Page 50 Pressure Gland Pipe O.D. D.I. Pipe No of Size of Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces. 3 350 7.69 3.96 50-56 4 5/8x2 5 7 4 350 9.12 4.80 50-56 4 5/sx2 6 13 6 350 11.12 6.90 50-56 6 5/8x2 11 20 8 250 13.37 9.05 50-56 9 5/sx2 13 25 10 250 15.62 11.10 50-56 12 %x2 18 33 12 150 17.88 13.20 50-56 16 5/8x2 23 38 14 250 20.25 15.30 53-56 20 %x21/2 44 55 16 200 22.50 17.40 53-56 24 %x21/2 51 64 0 18 200 24.75 19.50 53-56 24 %x2½ 62 72 20 200 27.00 21.60 53-56 28 %x3 73 91 24 150 31.50 25.80 53-56 32 5/8x3 93 118 * Not included in AWWA C 11 Tyler Utilities Division • 11910 C 492 • Tyler, Texas 75706 . (800) 527-8478 Union Foundry Company • Box 309 • Anniston, Alabama 36202 . (800) 226-7601 02/01/08 TYLER UNIONS SOLID & TAPPED PLUGS & CAPS TT DII 3-12' 14-24" 3-12" 14-24" MJ Plug Mi Cap Dimensions Max. Weights Size I Tap Plugs Caps 3 .46 2 9 8 4 .46 2 9 10 6 .46 2 18 18 8 .46 2 25 26 10 .56 2 36 32 12 .56 2 47 46 14 .62 2 76 85 16 .62 2 98 94 18 .65 2 138 121 20 .66 2 158 149 .68 2 223 210 .24 30 .66 2 355 345 36 .74 2 688 626 TAPPED TEE Mi Tapped Tee (2" Tap) Dimensions MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment SOLID SLEEVES Short Long Dimensions Weights Size T V L2 Short Long 3 .34 7.5 12 13 22 4 .35 7.5 12 19 25 6 .37 7.5 12 28 39 8 .39 7.5 12 38 55 10 .41 7.5 12 48 68 12 .43 7.5 12 62 81 14 .56 9.5 15 116 146 16 .57 9.5 15 138 174 18 .68 9.5 15 160 230 20 .69 9.5 15 212 269 24 .75 9.5 15 272 380 30 .66 15.0 15 500 30 .66 ... 24 ... 640 36 .74 15.0 15 725 36 .74 ... 24 ... 925 42 .82 ... 24 ... 1146 48 .90 ... 24 ... 1455 ADAPTERS IF MJxFE FExPE Dimensions Weights Size I L1 V MJxFE FExPE 18 26 23 36 35 50 50 60 69 88 88 127 155 149 275 470 750 7 3 .34 6 12 Size T L Max. Tap Weights 4 .35 6 12 3 .34 6 2 19 6 .37 6 12 4 .35 6 2 23 8 .39 6 12 6 .37 6 2 35 10 .41 6 12 8 .39 6 2 54 12 .43 6 12 10 .12 .41 .43 6 6 2 2 68 88 14 16 .51 .52 6 6 12 12 16 .52 6 2 164 20 .60 6 30 .66 7 36 .74 8 Tyler Utilities Division • 11910 C 492 . Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601 OrYLER UNION® WYES/LATE RAL MJxMJ MJSEBxPE MJLEBxPE PExPE 18 28 28 36 39 53 59 54 67 64 57 63 104 104 100 100 132 136 128 120 140 201 196 175 180 194 225 214 208 225 233 320 314 325 325 315 475 495 525 478 1185 1505 17 25 26 34 38 46 48 52 61 58 62 61 107 107 102 101 131 128 124 123 139 180 180 170 181 180 210 208 198 215 220 302 325 319 310 305 565 590 560 495 890 874 746 725 17 27 27 36 39 51 52 52 68 66 65 65 112 108 100 100 141 136 128 119 138 195 185 190 200 190 210 210 205 222 300 322 340 18 20 26 33 30 49 47 60 54 60 57 100 128 136 123 113 133 02/01/08 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment Dimensions Mi SEB LEB PE Weights Size T T1 L L L L Mi SEB LEB PE HAH - 43 .35 .34 3.0 8.5 8.5 14.0 *Wyes 6x3 .37 .34 5.0 10.5 10.5 16.0 6x4 .37 .35 4.0 9.5 9.5 15.0 Size A Dimensions V T T1 Weights 8x4 .39 .35 5.0 10.5 10.5 16.0 8x6 .39 .37 4.0 9.5 9.5 15.0 3 2.5 7.5 .34 .34 36 10x4 .41 .35 7.0 12.5 12.5 18.0 43 2.0 8.5 .35 .34 39 10x6 .41 .37 5.0 10.5 10.5 16.0 4 2.5 8.5 .35 .35 45 10x8 .41 .39 4.0 9.5 9.5 15.0 6x4 1.5 11.0 .37 .35 67 12x4 .43 .35 9.0 14.5 14.5 20.0 6 3.0 13.0 .37 .37 85 12x6 .43 .37 7.0 12.5 12.5 18.0 8x4 0.5 13.0 .39 .35 86 12x8 .43 .39 5.0 10.5 10.5 16.0 8x6 2.0 14.5 .39 .37 109 12x10 .43 .41 4.0 9.5 9.5 15.0 8 3.5 16.0 .39 .39 117 146 .51 .44 9.0 17.0 14.5 22.5 10x4 0.0 15.0 .41 .35 112 148 .51 .45 7.0 15.0 12.5 20.5 10x6 1.0 16.0 .41 .37 129 1410 .51 .46 5.0 13.0 10.5 18.5 10x8 2.5 17.0 .41 .39 162 14x12 .51 .47 4.0 12.0 9.5 17.5 10 3.5 19.0 .41 .41 199 16x6 .52 .45 11.0 19.0 16.5 24.5 12x4 0.0 16.5 .43 .35 141 16x8 .52 .46 9.0 17.0 14.5 22.5 12x6 1.5 18.5 .43 .37 170 16x10 .52 .47 7.0 15.0 12.5 20.5 12x8 1.5 18.5 .43 .39 177 16x12 .52 .48 5.0 13.0 10.5 18.5 12x10 3.0 20.0 .43 .41 216 16x14 .52 .51 4.0 12.0 12.0 20.0 18x8 .59 .45 14.0 22.0 19.5 27.5 12 4.5 22.5 .43 .43 269 18x10 .59 .47 12.0 20.0 17.5 25.5 t14 6.0 25.0 .51 .51 476 18x12 .59 .49 10.0 18.0 15.5 23.5 16x6 0.0 21.0 .52 .45 300 18x14 .59 .56 8.0 16.0 16.0 24.0 16x8 0.5 22.5 .52 .46 349 18x16 .59 .57 7.0 15.0 15.0 23.0 t16x12 3.5 25.0 .52 .48 471 20x10 .60 .47 14.0 22.0 19.4 27.5 t16 6.5 28.0 .52 .52 635 20x12 .60 .49 12.0 20.0 17.5 25.5 * Not included in A%WAC153 20x14 .60 .56 10.0 18.0 17.8 26.0 f Rated at 250 PSI. 20x1 6 .60 .57 8.0 16.0 15.8 24.0 MJ x 20x18 .60 .59 7.0 15.0 15.0 23.0 FE Flange Dimensions are on inside _cover. front ______________ 24x12 .62 .49 16.0 24.0 21.4 29.5 24x14 .62 .56 14.0 22.0 21.8 30.0 24x16 .62 .57 12.0 20.0 19.8 28.0 T 24x18 .62 .59 10.0 18.0 18.0 26.0 2420 .62 .60 8.0 16.0 16.0 24.0 30x16 .66 .50 30.0 39.0 30x18 .66 .54 28.0 37.0 30x20 .66 .57 24.0 33.0 U MfxPExMJTee 30x24 .66 .61 10.0 24.5 Dimensions 36x16 .74 .50 ... S Size T T1 H i' Z Weights 36x20 .74 .57 45.0 6 .37 .37 5.0 5.0 11.5 57 36x24 .74 .61 19.0 33.0 8x6 .39 .37 5.5 6.5 11.5 79 36x30 .74 .66 ... 24.5 8 .39 .39 6.5 6.5 12.5 83 42x30 .82 .66 20.0 ... 10 .41 .41 7.5 7.5 13.0 133 48x30 .90 .66 40.0 ... Tyler Utilities Division • 11910 C 492 . Tyler, Texas 75706 . (800) 527-8478 6 Union Foundry Company • Box 309 • Anniston, Alabama 36202 (800) 226-7601 18x6 .59 .44 6.5 14.5 15.5 18.0 275 261 279 18x8 .59 .45 7.5 14.5 14.5 ... 280 351 18x10 .59 .47 8.5 12.5 ... ... 286 18x12 .59 .49 9.5 12.5 ... ... 372 18x14 .59 .56 10.5 12.5 ... ... 415 18x16 .59 .57 11.5 12.5 ... ... 445 18 .59 .59 13.0 12.5 ... ... 490 20x6 .60 .44 7.0 16.0 17.0 19.5 335 362 358 20x8 .60 .45 8.0 14.0 ... ... 390 • 20x10 .60 .47 9.0 14.0 ... ... 417 20x12 .60 .49 10.0 14.0 ... ... 460 20x14 .60 .56 11.0 14.0 ... ... 475 20x16 .60 .57 12.0 14.0 ... ... 530 20x18 .60 .59 13.0 14.0 ... ... 560 20 .60 .60 14.0 14.0 ... ... 605 246 .62 .44 7.0 18.0 19.0 21.5 465 451 457 248 .62 .45 8.0 16.0 ... ... 475 2410 .62 .47 9.0 16.0 ... ... 516 24x12 .62 .49 10.0 18.0 ... ... 549 580 2414 .62 .56 11.0 16.0 ... ... 585 2416 .62 .57 12.0 19.5 ... ... 625 744 2418 .62 .59 13.0 16.0 ... ... 675 2420 .62 .60 15.0 17.0 ... ... 740 24 .62 .62 17.0 17.0 ... ... 844 30x6 .66 .36 7.00 20.0 ... ... 700 30x8 .66 .38 8.50 20.0 ... ... 739 30x12 .66 .42 10.0 20.0 ... ... 739 30x16 .66 .50 12.5 20.0 ... ... 959 30x20 .66 .57 15.0 20.0 ... ... 995 30x24 .66 .61 16.0 20.0 ... ... 1160 30 .66 .66 20.0 20.0 ... ... 1323 36x16 .74 .50 12.5 23.5 ... ... 1350 36x24 .74 .61 16.0 23.5 ... ... 1498 36x30 .74 .66 20.0 23.5 ... ... 1555 36 .74 .74 23.5 23.5 ... ... 1900 42 .82 .82 30.0 30.0 ... ... 3175 f Weights include swivel gland. Swivel x Solid Adapter with Swivel Gland Size by Wall Laying Length Thickness Weight 6x13 .37 52 6x18 .37 65 6x24 .37 69 8x12 .39 52 Swivel x Swivel Adapter Size by Wall Laying Length Thickness Weight 6x12 .37 28 6x18 .37 49 6x24 .37 52 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION Sizes 3" thru 12" UL Listed For Fire Main Equipment TEES (Continued) MJ GLANDS MJ Tee MJ x FE Tee MJ x Swivel Tee Dimensions Weights Size T T1 H i1 J2 J3 Mi MJxFE fMJxS Glands Size Weight Size Weight 3 3 12 10 4 4 14 17 6 5 16 21 8 6 18 22 10 9 20 32 24 37 Tyler Utilities Division • 11910 C 492 • Tyler, Texas 75706 (800) 527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston, Alabama 36202 (800) 226-7601 5 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment drYLER UON® TEES CROSS MJ Tee MJ x FE Tee MJ x Swivel Tee Cross Dimensions Weights Size T Ti H J1 J2 P MJ MJxFE fMJxS Cross 3 .34 .34 3.5 3.50 5.5 ... 26 29 ... 31 43 .35 .34 3.5 4.00 6.5 ... 35 34 ... 39 4 .35 .35 4.0 4.00 6.5 ... 36 39 ... 45 6x3 .37 .34 4.0 4.00 6.5 ... 51 54 6x4 .37 .35 4.0 5.00 8.0 ... 52 57 ... 62 6 .37 .37 5.0 5.00 8.0 10.50 66 68 77 79 8x3 .39 .34 4.0 6.50 9.0 ... 56 8x4 .39 .35 4.5 6.50 9.0 ... 72 82 ... 84 8x6 .39 .37 5.5 6.50 9.0 11.50 79 81 105 98 .39 .39 6.5 6.50 9.0 11.50 90 101 116 112 .8 100 .41 .34 4.0 7.50 11.0 ... 80 10x4 .41 .35 4.5 7.50 11.0 ... 82 92 ... 98 10x6 .41 .37 5.5 7.50 11.0 13.00 99 116 114 121 10x8 .41 .39 6.5 7.50 11.0 13.00 116 128 138 135 10 .41 .41 7.5 7.50 11.0 ... 132 144 ... 156 120 .43 .34 4.0 8.75 12.0 ... 99 12x4 .43 .35 4.5 8.75 12.0 ... 108 118 ... 119 12x6 .43 .37 5.5 8.75 12.0 14.25 119 133 132 138 12x8 .43 .39 6.5 8.75 12.0 14.25 126 146 149 149 1200 .43 .41 7.5 8.75 12.0 ... 159 174 ... 187 12 .43 .43 8.75 8.75 12.0 ... 171 198 ... 202 146 .51 .44 6.5 10.50 14.0 16.00 183 205 211 210 148 .51 .45 7.5 10.50 14.0 ... 211 ... ... 231 14x10 .51 .46 8.5 10.50 14.0 ... 229 244 ... 255 1412 .51 .47 9.5 10.50 14.0 ... 245 284 ... 269 14 .51 .51 10.5 10.50 14.0 ... 281 291 ... 299 16x6 .52 .45 6.5 11.50 15.0 17.00 222 230 243 250 16x8 .52 .46 7.5 11.50 15.0 ... 245 248 ... 264 16x10 .52 .47 8.5 11.50 15.0 ... 265 287 ... 286 16x12 .52 .48 9.5 11.50 15.0 ... 277 312 ... 312 16x14 .52 .51 10.5 11.50 15.0 ... 317 348 16 .52 .52 11.5 11.50 15.0 ... 337 324 ... 457 30 .66 .66 22.0 22.00 ... ... ... ... ... 1840 36 .74 .74 26.0 26.0 ... ... ... ... ... 2655 0 f Weights include swivel gland Tyler Utilities Division • 11910 CR 492 • Tyler, Texas 75706 (800) 527-8478 4 Union Foundry Company• Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/08 I-' MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION® Sizes 3" thru 12" UL Listed For Fire Main Equipment C BENDS Y ./ 900 Bend MJ x PE (1/4) 450 Bend Mix PE (1/8) 221/20 Bend MJ XPE (1/16) 11¼° Bend MJ x PE (1/32) Size I Dimensions A Y R Weight Dimensions A Y R Weight A Dimensions Y R Weight A Dimensions Y R Weight 3 .34 3.5 9.0 2.5 18 2.0 7.5 2.41 17 1.50 7.00 2.51 19 1.25 6.75 7.62 15 4 .35 4.0 9.5 3.0 26 2.5 8.0 3.56 22 1.75 7.25 3.81 20 1.50 7.00 5.12 20 6 .37 6.0 11.5 5.0 45 3.2 8.7 5.49 38 2.25 7.75 6.35 33 1.50 7.00 5.12 32 8 .39 7.5 13.0 7.0 64 4.0 9.5 8.44 55 2.84 8.34 11.80 51 2.05 7.55 15.80 44 10 .41 9.5 15.0 9.0 108 5.0 10.5 10.88 78 3.35 8.85 14.35 66 2.31 7.81 18.36 60 12 .43 9.0 14.4 6.0 114 6.0 11.5 13.25 104 3.50 9.00 12.70 89 2.56 8.06 20.90 79 14 .51 12.0 20.0 11.5 219 5.5 13.4 10.85 165 3.93 11.93 17.25 152 2.59 10.59 21.25 137 16 .52 13.0 21.0 12.5 254 6.0 14.0 13.25 206 3.98 11.98 17.50 181 2.62 10.62 21.50 161 24 .62 17.0 25.0 15.5 710 7.5 16.6 14.69 460 9.00 17.66 37.69 455 9.00 26.12 12.00 475 30 .68 21.5 30.5 -- 865 10.5 19.5 -- 715 6.75 15.75 -- 600 -- -- -- -- 90° Bend MJ x Flange 45° Bend MJ x Flange 221/20 Bend MJ x Flange 111/4* Bend MJ x Flange (1/4) (1/8) (1/16) (1/32) Dimensions Dimensions Dimensions Dimensions Size T A R F Weight A R F Weight A R F Weight A R F Weight 3 .34 3.5 2.5 5.5 21 ... ... .. .. ... ... .. .. ... 4 .35 4.0 3.0 6.5 28 2.50 3.56 4.0 34 1.75 3.81 4.0 34 1.50 5.12 4.0 19 6 .37 6.0 5.0 8.0 45 3.25 5.49 5.0 57 2.25 5.35 5.0 57 1.50 5.12 5.0 30 8 .39 7.5 7.0 9.0 73 4.25 7.93 5.5 83 2.50 7.62 5.5 83 1.75 7.70 5.5 50 10 .41 9.5 9.0 11.0 113 5.00 9.76 6.5 122 3.00 10.16 6.5 122 2.00 10.25 6.5 75 12 .43 10.5 10.0 12.0 141 6.00 12.19 7.5 159 3.50 12.70 7.5 159 2.25 12.82 7.5 88 14 .51 12.0 11.5 14.0 217 5.50 10.85 8.5 207 16 .52 13.0 12.5 15.0 280 6.00 12.02 9.5 290 B 90° Swivel x Swivel Hydrant Ell Dimensions J Size T A B E F R 1 *Weight S o .37 10.5 15.5 6.90 11.2 6.81 7.98 6.0 74 * Weight includes two swivel glands. Tyler Utilities Division • 11910 CR 492 • Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company ' Box 309 . Anniston, Alabama 36202 . (800) 226-7601 3 MJxMJ *OFFSETS MJxPE Dimensions Weights Size D L1 L MJxMJ MixPE 4 6 10 -- 45 -- 4 12 16 -- 55 -- 4 18 22 -- 65 -- 4 24 28 -- 75 -- 6 6 12 17.5 41 54 6 12 18 -- 65 -- 6 18 24 -- 75 -- 6 24 30 -- 85 -- 8 6 13 -- 84 -- 8 . 8 12 19 -- 90 -- 18 25 -- 100 -- * Not included in AWWAC153. D MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS .TYLER UNION Sizes 3" thru 12" UL Listed For Fire Main Equipment BENDS 900 Bends (1/4) 450 Bends (1/8) 221/2° Bends (1/16) 111/4° (1/32) Dimensions Dimensions Dimensions Dimensions Size T A R Weight A R Weight A R Weight A R Weight 3 .34 3.5 2.5 19 2.00 2.41 17 1.50 2.51 15 1.25 2.53 16 4 .35 4.0 3.0 26 2.50 3.56 22 1.75 3.81 20 1.50 5.12 20 6 ' .37 6.5 6.0 49 3.50 7.25 39 2.25 6.35 31 1.50 5.12 29 8 .39 7.5 7.0 64 4.00 8.44 56 2.85 11.80 50 2.06 15.80 45 10 .41 9.5 9.0 102 5.01 10.88 78 3.35 14.35 66 2.32 18.36 59 12 .43 10.5 10.0 129 5.98 13.25 102 3.86 16.90 87 2.56 20.90 82 14 .51 12.0 11.5 214 5.50 12.06 155 3.93 17.25 142 2.59 21.25 136 .52 13.0 12.5 273 5.98 13.25 204 3.98 17.50 178 2.62 21.50 157 8 40 6 .59 15.5 14.0 411 6.50 12.36 292 7.50 30.19 286 3.00 60.84 283 20 .60 17.0 15.5 519 7.00 13.59 372 8.50 35.19 376 3.50 71.07 374 24 .62 17.0 15.5 721 7.50 14.89 490 9.00 37.69 512 3.50 76.12 487 30 .66 21.50 19.0 930 10.50 9.31 716 6.75 21.36 665 4.75 22.84 600 36 .74 24.50 22.0 1450 11.50 21.73 1110 7.75 26.39 960 5.00 25.38 820 42 .82 29.25 26.7 2205 14.00 27.76 1610 9.00 32.68 1350 6.00 35.54 1180 48 .90 33.25 30.75 2990 15.00 30.17 2090 10.00 27.70 1760 6.50 40.61 1475 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 . (800) 527-8478 2 Union Foundry Company Box 309 • Anniston, Alabama 36202 (800) 226-7601 02/01/08 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS C TYLER UNION Sizes 3" thru 12" UL Listed For Fire Main Equipment SAMPLE SPECIFICATIONS Mechanical Joint watermain fittings with accessories, 3" through 48" shall be manufactured from Ductile Iron in accordance with and meet all applicable terms and provisions of standards ANSI!AWWA Cl 53/A21.53 ANSI! AWWA 1111/A21 .11 (current revisions). Ductile Iron Mechanical Joint Fittings 3" through 24" shall be rated for 350 PSI working pressure. 30" through 48" shall be rated for 250 psi working pressure. Flanged ductile-iron fittings in 24-in. (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. All coated fittings meet requirements of NSF-61. NOTE - EXCEPTIONS: Mechanical Joint Fittings with flanged branches are rated for water pressure of 250 PSI. NOTE: Fittings are CEMENT LINED and seal coated in accordance with ANSI/AWWA Cl 04/A21.4; also available double cement-lined, bare or epoxy coated. S IT JOINT DIMENSIONS IN INCHES BOLTS Size A Dia. B C Dia. D Dia. F Dia. J Dia. K1 Dia. K2 Dia. L M S I X Size No. 3 3.96 2.50 4.84 4.94 4,06 6.19 7.62 7.69 .58 .62 .39 33 3/4 5/sx3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9,06 9.12 .60 .75 .39 .34 '/s 3/4X31/2 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 /8 3/401/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 7/ 3/401/2 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 /8 3/401/2 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 /8 3/401/2 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .56 .47 ?'/ 3/4X4 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .57 .50 /s 3/4x4 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 /8 3/4X4 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 /8 3/4x4 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1,56 .75 .61 % 3/4X4½ 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1'/s 1x5½ 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1 Y 1x51/2 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1% 1¼x6V2 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1/s 11/4x6½ 32 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 II S / a I - Mechanical Joint C1 53/A21.53 go TYLER UNION* Quality Waterworks products Revised 10/09 (Curr,.nt Revisionsf SIZES ............................2" through 48" (2" Not Referenced in C1 53/A21.53) STANDARDS: ................. ANSI/AWWA C153/A21.53-06 and NFPA 3"-12" UL Listed (EX2 111) Note: Cast with tested and traceable ASTM A536 Ductile Iron PRESSURE RATING: 2"- 24" rated @ 350 PSI; 30"- 48" & all fittings with Flanged branches rated @ 250 PSI Note: With use of special flange gasket 2"-24" flanged fittings can be rated @ 350 psi Note: Compact Wyes over 12" are not pressure rated. Contact manufacturer for rating in your application. DEFLECTION:.................Upon completion of installation, Mechanical Joint fittings 2"-12" are rated for a maxi- mum of 50 deflection and 14"-48" a maximum of 30 deflection NSF-61 ..........................Meets all requirements, UL Registered (2"-48") BITUMINOUS COATING: ...................... ANSI/AWWA C104/A21 .4-08 CEMENT LINING: .......... ANSI/AWWA C1 04.A21.4-08, Double cement lining available EPDXY COATING:.......... ANSI/AWWA Cl16/A21.16-09 Note: Epoxy coated fittings are available to the specification required for your application(s) BARE'............................. Available BOLTS . ........................... ANSI/AWWA C111/A21.11-7 INSTALLATION: ............. Per AWWA C600-99 using pipe conforming to ANSI/AWWA C151/A21.51-02 I Size A Dia. B C Dia. D Dia. F Dia. J Dia. K1 Dia. K2 Dia. L M S I X Size No. 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 3/4 %x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 /8 3/4x31/2 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 /8 3/4X31/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 /8 3/4x4 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 /8 3/4x4 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 78 3/4X4 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 78 3/4x41/2 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 78 3/4X41/2 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 7/8 3/4X41/2 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 ¼ 3/4x41/2 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 ¼ 3/4x5 16 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1Y8 1x6 20 S 30 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1Y8 1x6 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1,25 .82 1% 1 1/4x61/2 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1% 1 1/4x61/2 32 Tyler Pipe Company' 11910 CR 492 'Tyler, Texas 75706 ' (800) 527-8478 Union Foundry Company 1501 W. 1 7th Street Anniston, Alabama 36202 (800) 226-7601 www.tylerunion.com