Loading...
HomeMy WebLinkAbout5630 PASEO DEL NORTE; 135D; FPC2019-0193; PermitPermit No: FPC2019-0193 CARLSBAD, CA 92008-4469 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Status: Closed - Finaled Applied: 08/13/2019 Issued: 09/03/2019 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: PERMIT REPORT (Ccity of Carlsbad Print Date: 11/03/2021 Job Address: 5630 PASEO DEL NORTE, # 135D, Permit Type: FIRE-Construction Commercial Parcel #: 2110222202 Valuation: $434,124.34 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: ADIDAS -SPRINKLER TI (41 HEADS) Applicant: COSCO FIRE PROTECTION MAlT JORGENSEN 4990 GREENCRAIG LN SAN DIEGO, CA 92123-1673 (858) 444-2000 FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov San Diego Branch Office . I cosco 4990 Greencraig Lane S San Diego, CA 92123 S •. ... Fire Protection (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www. coscofire. CO1H MATERIAL SUBMITTAL Date: 8-2-19 ADIDAS - CARLSBAD PREMIUM OUTLETS 5630 PASEO DEL NORTE SUITE 135D "Oil CARLSBAD, CA 92008 JOB # 1O.CD 5928 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. FPC20I9-0193 5630 PASEO DEL NORTE #1350 ADIDAS - SPRINKLER TI (41 HEADS) 2110222202 8/13/2019 Submitted by: MATT JORGENSEN FPC20I 9-0193 - - Los Angeles • San Francisco • Orange 0 Fresno 0 San Diego • Seattle Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Standard Response Fusible Link Upright Sprinkler VK108 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in Approval Chart 1. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Classes 2016 and 2017 Refer to the approval charts and design criteria for Listing and approval requirements that WARNING: Cancer and Reproductive Harm- must be met. www.P65Warnings.ca.gov TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT Nominal K-Factor: 5.6 U.S. (80.6 metric**) Overall Length: 2-1/4" (58 mm) ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C 19500 Fusible Link Assembly: Brass UNS-C40500 and UNS-051000 NOTE: For chrome sprinklers, the fusible link assembly is painted silver for decorative purposes only. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Seat: Copper UNS-C11000 Pip Cap Attachement: UNS-C36000 For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Viking Standard Response Fusible Link Upright Sprinkler VK108 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-AN, Black Polyester = M-/B, Wax Coated = C Temperature Suffix: 165 °F (74 °C) = C, 220 °F (104 °C) = F, 286 °F (141 °C) = G For example, sprinkler VK108 with a 1/2" thread, Brass finish and a 165 °F (74 °C) temperature rating = Part No. 12973AC Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B (available since 2000) Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A ½" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) Form No. F_052214 18.10.11 Rev 17.2.P65 Replaces Form No. F_052214 Rev 17.2 (Added P65 Warning.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Standard Response Fusible Link Upright Sprinkler VK108 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. S S Form No. F_052214 18.10.11 Rev 17.2.P65 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Maximum Ambient Temperature Rating' Ceiling Temperature2 Ordinary 165 OF (74 °C) 100 OF (38 °C) Intermediate 220 OF (104 °C) 150 OF (65 °C) High 286 OF (141 °C) 225 OF (107 °C) Sprinkler Finishes: Brass, Chrome, White Polyester, and Black Polyester Corrosion-Resistant Coatings": White Polyester and Black Polyester in all temperature ratings. Wax-Coated Brass for sprinklers with the following temperature ratings: 165 OF (74 °C) Lt. Brown Wax 220 OF (104 °C) Dark Brown Wax' Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 CC). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 °C) response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. Wax melting point is 170 OF (76 °C) for 220 °F (104 °C) temperature-rated sprinklers. Protective Sprinkler Cap - Wrench Flat 21475:=* 10896 Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475M/B Coated Sprinklers 10896W/B Figure 1: Standard Sprinkler Wrenches Form No. F_052214 18.10.11 Rev 17.2.P65 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY Standard Response Upright Sprinkler VK108 Maximum i75 PSI (12 ba)P Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Base Part SIN (Refer also to UL Design Criteria.) Number' NPT I BSP U.S. I metric2 Inches I mm cULus4 VdS LPCB (E Standard Orifice El2973 VK108 1/2" 115 mm 1 5.6 80.6 2-1/4" 1 58 1 A2, Bi - NOTICE7Product Limited 7Availability (Contact Local 05557 VK108 1 1/2" 115 mm 1 5.6 80.6 2-3/16" 1 56 A2, 61 -- -- -- Approved Temperature Ratings Approved Finishes A - 165 °F (74 °C), 220 °F (104 °C) and 286 °F 1 - Wax-Coated Brass (corrosion resistant) (141 °C) B - 165 °F (74 °C) and 220 °F (104 °C) 2 - Brass, Chrome, White Polyester5'6, and Black Polyester5'6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Viking Standard Response Fusible Link Upright Sprinkler VK108 is cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. S I Form No. F_052214 18.10.11 Rev 17.2.P65 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) - -.. Standard Response Upright Spr inkler VK108 +ç— Fjnth Maximum 175 PSI (12 bar) WWP AiX4scutth&'n aI3e) Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals' Part Number' SIN (Refer also to Design Criteria below.) NPT I BSP U.S. metric2 Inches mm Standard Orifice 12973 1 VK108 1/2" 1 15 mm 1 5.6 80.6 2-1/4' 58 Al L.1tt Limited Availability (ContactTJLocal T7Viking I.J/il 05557 VK108 1/2" 15 mm 5.6 1 80.6 1 2-1/4" 1 58 Al Approved Temperature Ratings Approved Finishes A- 165°F (74 °C), 220°F (104 °C), and 286°F (141 °C) 1 - Brass, White Polyester', and Black Polyester' Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. DESIGN CRITERIA-FM (Also refer to Approval Chart 2) FM Aooroval Requirements: Sprinkler VK108 is FM Approved as a standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052214 18.10.11 Rev 17.2.P65 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. Wax Coated Upright Sprinkler ** A 1/2" ratchet is required Step 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Socket Wrench 13577W/B for Wax Coated Sprinklers S Form No. F_052214 18.10.11 Rev 17.2.P65 Replaces Form No. F_052214 Rev 17.2 (Added P65 Warning.) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com The 'liking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and-are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 11 VdS Approved: Certificates G414009 and G414010 LPCB Approved (( CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer toApproval Chart I and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Crite for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.02.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY S The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. S Protective Sprinkler Wrench Flat Clip LL_ [iProtective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 17.02.02 Rev 17.1 Sprinkler wrench 13655W/B* for recessed pendent , sprinklers ** A 1/2" ratchet is required (not available from Viking) Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE W AVAI LABLE 11I •TEMPERATURE R1ll[ IIIFINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb C I u o or Ordinary 135 OF (57 °C) 100 OF (38 °C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 OF (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. Thesi tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers p Form No. F033314 17.02.02 Rev 17.1 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature The Viking Microfast Quick Response KEY Pendent Sprinkler VK302 A&' Escutcheon (f appabe) Maximum 1,75, PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN style K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric- Inches mm cULus' VdS LPCB CE 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, BIY D1Z, C1Y -- 19780 VK302 Pendent 1/2" -- 56 80.6 2-1/4 58 -- -- -- -- -- 03 21354 VK302 Pendent -- 15 mm 1 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 NOTICE - 17TI:1F Availability (Contact T.J/ilj 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, 02, C2X -- -- -- -- 18021 VK302 n Pe dent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1X,B1Y Al A1X,B1Y D1X,C1Y8 D1X,C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester5'6, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter5'6 Y - Standard surface-mounted escutcheon or the (79 °C), and 200 OF (93 °C) 2 - ENT' Viking Microfast5 Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C -155°F (68 °C), 175°F (79 °C), and 3-Chrome matice Model E-1, E-2, or E-3 Recessed Escutcheon 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the 0-155°F (68 °C), 175°F (79 °C), 200°F Viking Microfast Model F-1 Adjustable Escutcheon 93 °C), 286 OF (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA UL (Also refer to Approval Chart I above) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- iards, whenever applicable. Form No. F033314 17.02.02 Rev 17.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) KEY The Viking Microfase Quick Response F,th AIX 4— Escutcheon (f appcab1e) Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AIZ, B1Y, D2X, C2 L.)tI. I:It1'I Limited Availability(Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, BIY, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the 135 °F(57 °C), 155 °F(68 °C), 175 °F(79 °C), 200°F Viking Micromatic® Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon 135 -F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1- Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfast® Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 °F (141 °C) or E-2 Recessed Escutcheon 0 - 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or th Viking Microfast® Model F-i Adjustable Escutcheo Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA.- FM (Also refer to Approval Chart 2 above) FM Arrnroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. I Form No. F_033314 17.02.02 Rev 17.1 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1/2" (15 mm) NPT. Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-1/4" (57 mm) 2" (51 mm) Max. 1-1/2" (38 mm) Mm. Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon C 2-1/8' - (54 mm) 1-3/4" (45 mm) Max. : (54 mm) 21119 (51 mm) iq *14 -.;.- Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-I Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.02.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) KfA AVA AA LC7- SchedulewlO/ScheduleAO - ABFII S Fully Listed and FM Approved Sprinkler Pipe When you specify Allied Schedule-10/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (11/4"- 8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. > Galvanized Pipe Schedule-10/Schedule-40 -ABFII product can be hot-dip galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII" In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* > American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ) Specifications & Approvals Schedule-10/Schedule-40-ABFll pipe are in compliance with the following: ASTM A-i 35, Type E Grade A, and NEPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall RiirltIIr 1 I'ABFIIIIISpecifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 1.049 1.680 2.05 25 26.6 2.5 3.05 - 11/4 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 11/2 2.720 3.61 1 40 40.9 4.0 5.37 - 2.067 3.650 5.13 1 50 52.5 5.4 7.63 - 21/2" 2.469 5.790 7.86 1 65 62.7 8.6 11.73 - Sch-10 - ABFII Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 11/4 1.442 1.810 2.525 7.0955 32 36.6 2.7 3.75 - 11/2 2.080 3.04 5.6570 40 42.7 3.1 4.52 - 2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 - 21/2" 2.635 3.530 5.89 3.5196 65 66.9 5.3 8.77 - 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - * See ABFII warranty APPMOVED Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com (-T~alhed • 16100 S Lathrop Ave. • 11350 Norcorn Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 **,rnoAtkOre * (~~ <lt~> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 FITTINGS S • 'A Division ofSiar Pipe Produces t.1_I IIRONII'!DEGREE EL :JsY NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS W13GK1 - A B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 21/2 CB90077 300 2.70 2.70 4.75 wE.1: I :t.] 1:1 'XsL.1U Jul NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WAGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST IRON STRAIGHTji I NOMINAL SIZE (INCH) ITEM CODE ___ MAX. WORKING P.5.1. DIMENSIONSj WEIGHT EACH PIECE 1 CT333 300 EB 1.21 11/4 CT444 300 1.87 11/2 CT555 300 2.51 2 CT666 300 2.25 2.25 3.96 21/2 C1777 300 2.70 2.70 6.45 CAST1IRON 45 DEGREE I I NOMINAL SIZE (INCH) ITEM CODE I MAX. IDIMB4S WORKING P.S.I. IONS I WEIGHT I EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 CB45055 1 300 1.43 1.43 1.80 2 1 CB450661 300 1 1.68 1 1.68 1 2.79 O C.I. THREADED FITTINGS CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME B16.14. THREADS ARE NPT PER ANSI/ASME 13I.20.1. I CASTIIRON1RED. 90 DEG.ELBOW NOMINAL SIZE (INCH) ITEM CODE WORKING P.S.I. ' MAX. IDIMENSI0NS WBGHT I EACH PIECE - A I - B 1X1/2 C690031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 C890043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 t65 1.80 1.51 Ii 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB900641 300 1.90 2.10 1 2.30 2X1 1/2 1 CB900651 300 2.02 2.16 1 2.60 Page 38 CASTgIRON PLUGS I NOMINAL SIZE (INCH) I ITEM CODE ' MAX. IDIM WORKING P.S.I. B4SIONI WBGIff I EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPLOO4 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPLOO6 300 1.56 0.91 .1:I IIRON CROSS NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. IDIM I0I WEIGHT' EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1 1.65 1 1.80 2.40 2X1 CX063 300 1 1.73 1 2.02 2.75 A A C.I. THREADED FITTINGS FITTINGS A Di'tios fSIar Pipe Products (q (~~ <*> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CASTIIRONI REDUCING I NOMINAL SIZE (INCH) ITEM I CODE _ _______ MAX. ' WORKING P.S.I. DIMB1SIONS 'WEIGHT EACH PIECE A B C 1X1X172 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT 32 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 114X2 CT446 300 2.10 2.10 1.90 --2-.F5- 1 1/2X1X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 112X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 C 154 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 I 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 16 2.25 3.75 2X2X1/2 CT661 300 49 1.88 2.60 2X2X3/4 CT662 300 60 1.97 2.71 2X2X1 CT663 300W 2.O2 300 73 2.02 2.97 2X2X1 1/4 CT664 300 90 2.10 3.32 2X2X1 1/2 CT665 300 02 2.16 3.72 2x2x2 1/2 CT667 300 60 2.39 1 5.10 Page 39 STYLES 920 AND 920N STYLE 920 CROSS PATENTED Mechanical-I® Bolted Branch Outlets ICBI VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N S Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. .JOB/OWNER System No. Location CONTRACTOR Submitted By Date ENGINEER Spec Sect Para Approved Date www.victaulic.com VIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REV K X, A C_ _ta _U1 ii C r 11.02 1 GROOVED OUTLET CARBON STEEL PIPE - HOLE CUT PRODUCTS 1. i.0 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IvthIgI FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 750 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Dimensions III Map Mao . WW iiii u QD (M It 2 ½ (a) C 920N 500 I 1.50 200 2.53 - 1.61 I 5.35 275 -- 3.1 50 15 -3450 ) P' I '. I ZP 1.5 3/4 (a) C 920N 500 1.50 1.97 2.53 1.61 I 5.35 2.75 3.1 20 3450 38.1 50 - 64 41 136 70 1.5 - 1(a) C 9 0 2 N 500 I 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 47 - 41 136 70 1.4 - 1 114 (a) to 920N 500 I 1.75 2.05 2.75 I 3.00 1.61 5.35 3.00 3.5 3.2 32 3450J 44.5 52 70J 76 41 136 76 1.7 LS 1 ½ (a) to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 500 44.5 1.50 52 70 79 41 91.82 136 5.64 83 2.75 1.7 3.0 1.5 21/2 1/2 (a) §" 920N 2.21 2.74 65 15 3450 38.1 56 70 - 46 143 70 1.4 1 - 1/4 (a) §0 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 1.82 5.64 2.75 2.9 1(a) §0 920N 500 1.50 2.06 2.74 25 3450 38.1 52 70 - 46 143 70 1.4 - 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 1/41(a) C 3.2 32 3450 44.5 58 76 83 46 160 76 1 1.7 1.5 500 3.25 1.82 6.26 3.25 1 3.6 3.3 11/2 1(a) a 920N 2.00 2.28 3.00 40 3450 50.8 58 76 83 46 2.25 159 6.46 83 4, 3.18 1.7 3.9 1.6 ½ (a) 76.1 x 920N 300 1.50 2.22 2.75 15 2065 381 56 70 - 57 164 81 18 - 920N 300 1.50 2.19 2.25 6.46 3.9 3/4 (a) 3.18 20 2065 38.1 56 70 - 57 4 164 81 1.8 - 300 1.50 2.07 2.75 - 2.25 6.46 3.8 1(a) 920N 3.18 - 25 2065 38.1 53 70 1 57 164 81 1.7 1'/4(a) C 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 920N 2.28 3.00 3.31 1.92 6.29 3.25 3.5 1112 (a) C 500 2.00 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 x 1/2 (a) C 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - '14 )a) C 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 -1 58 156 1 70 1.6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 - 1.75 2.55 3.25 3.56 2.28 6.15 1 1/4 (a) tC 920N 500 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1,8 1 1.8 1½ (a) IC 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40)b) 3450 0.8 I 71 89 90 58 156 83 1.9 1.8 50 !63.5 4.6 2 (a) C 920N 500 2.75 -t..----------3.50 3.56 2.28 6.75 3.88 4.9 50 3450 70 89 90 1 58 1172 1 99 2.3 2.1 31/2 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 __50 90 3450 _63.5 I 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order, I Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 2 \4taulicr REV K STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 112150 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets IJI[h.1[.1d. I " ' !L .i( - - J(...._ - TABLE CONTINUED FROM PAGE 2 4 ½ (a) 920N 500 1.50 303 1 3.56 2.69 701 2.75 3.7 100 15 3450 ,J 38.1 77 90 - 68 178 70 1.8 - 3/4 (a) 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 1(a) a 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1¼ (a) ta 920N 32 (b) 3450 44.5 78 96 102 , 68 178 76 1.9 1.8 920 N 7.01 1 1/2 (a) (u 500 2.00 3.28 4.00 4.00 2.69 3.25 4.2 3.9 40(b) 3450 50.8 83 102 - 102 .-----.+ 68 178 83 2.0 1.9 -. -- 500 3.25 4.00 4.00 3.88 5.0 2(a) to 920N 2.50 2.69 7.01 1 4.6 50 3450 63.5 83 102 102 68 178 99 23 2.1 21/2 (a) 1 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4,63 5.8 5.0 65 - 52_ 69.9... 73 19 48 ...i!L .i 500 2.88 4.00 2.69 7.34 761 mm 920 2.75 4,63 6.4 3450 69.9 73 - 102 68 186 118 - L2.9 920 500 3.50 3.31 4.50 4.12 2.69 7.73 3(a) t 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 1 2.9 500 1.75 3.08 3.78 2.63 764 3.05 5.0 1¼ (a)u 108.0 x 920N 32 3450 44.5 78 96 67 1 194 78 2.3 - 920N 500 2.00 3.28 4.00 2.63 764 11/2 (a)u 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 2.3 - 2 (a) 920N 500 2.50 3.25 4.00 I 2.63 764 4.00 4.0 50 3450 63.5 83 102 - J 67 194 102 1.9 - 2 0 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 76.1 mm 3450 1 69.9 1 73 102 102 j 67 194 109 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 763 4.88 6.8 6.5 80 3450 88.9 84 114 114 .4.., 67 194 124 3.1 3.0 5 11/2 (a)'( 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 74 76 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a) t 50 920 500 3450 2.50 63.5 4.00 102 4.75 121 4.75 121 3.16 80 9.70 1 246 4.38 111 8.2 3.7 8.0 3.6 21/2 (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm u 920 500 2.75 3.75 4.75 3.16 9.70 4,63 8.0 3450 69.9 95 - 121 80 246 118 - 3,6 3 (a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 1 127 1 118 80 3.17 246 8.00 135 3.88 3.8 --4.0 2 133.0 x 920 N 500 2.50 3.75 4.50 8.0 50 3450 63.5 95 114 - 81 203 99 3.6 - 500 3.50 3.81 5.00 3.00 920 9.46 5.31 8.0 t - 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be 1- Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections, # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. Vds approved for fire protection services u LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV K htauiicr 11.07 3 CARBON STEEL PIPE- HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET 151 oil, h :M-W FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Style Max. Work No. Pressure@ DimensionsSize - We TABLE CONTINUED FROM PAGE 3 1 ½ t 139.7 x 920N 500 2.00 378 ' 450 330 8.23 3.25 7.0 40 3450 508 96 114 - 84 209 83 3.2 - 92 ON 4.50 3.30 8.23 3.88 9.0 2 t I 500 2.50 3.75 50 3450 63.5 95 114 - 84 209 99 3.25 4.1 5.1 - 4.8 6 1 '< 920N 500 1.75 4.43 513 513 3.79 9.15 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 1 1/2 (a) ta 920N 500 40(b) 3450 50.8 112 130 1 130 96 232 83 2.4 2.3 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 2(a) to 920N 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 920 I 4.15 5.21 3.69 10.51 4.63 761 mm a 500 2.75 8.4 3450 69.9 j 105 - 132 94 267 118 - 3.8 920 500 3.50 4.31 5.50 5.13 3.69 10,51 5.31 3 (a)t 9.9 8.4 80 3450 .24 110 140 130 94 267 1 135 4.5 3.8 920 500 4.50 3.81 5.38 3.69 10.51 6.25 10.1 10.1 4(a) to 5.75 100 3450 500 114.3 97 146 137 94 267 159 4.6 7.8 4.6 1590 x 1½ (a) 920N 2.00 4,41 5.13 3.63 9.40 3.25 40 3450 50.8 112 130 - 92 239 83 3.5 - 2(a) 920N 500 2.50 4,38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 761 mm 920 3450 69.9 111 140 130 92 239 118 4.3 - 4.3 8.1 14.0 920 500 3.50 4.31 5.50 5.13 3.63 I 9.40 5.31 80 3450 88.9 110 140 130 92 239 135 3.7 614 920 I 4.45 5.38 9.40 1080 mm 500 4.50 3.63 6.12 10.0 3450 114.34 113 - 137 92 239 155 - 4.5 920 3.81 3.63 9.40 6.25 18.0 500 4.50 5.75 100 3450 114.3 96.80 146 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services I..PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com vlcTAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 4 \,Ltaulic REV K I CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm Style Max.Work Approx. Size No.IItnI.l,I.11.l,I. Weight ______________ 'Z!) L1t1i. . ij4 nJ J 't 1 'fl13 UiLW3 I.1L 'r- I.fl1iLL .3:€7.. 1.€jjj Lk 4i611 TABLE CONTINUED FROM PAGE 4 165.1 x 25 920N 500 3450 50 381 3.88 99 4.56 116 - 3,79 96 9,34 237 2.75 70 8.0 3.6 I - 1 1/4 32 920N 500 3450 1.75 1 44.5 4.43 113 5.13 130 - 3.79 96 9.34 237 3.25 83 8.4 3.8 - 1½ (a) t 920N 500 8.4 5.4 2.00 -- 4.41 5.13 - 5.13 I 3.79 -- 9.34 3.25 40 3450 50.8 112 130 130 j 96 237 83 3.8j 2.4 920N 500 2.50 4.38 5.13 9.34 3.88 2 (a) 1' 5.13 3.79 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 8.6 ' 7.6 500 2.75 4.01 5.13 5.21 3.63 10,51 4.63 761 mm 3(a)to 920 3450 j 500 69.9 I 3.50 110 4.31 130 5.50 132 5.13 92 3.63 267 10.51 118 3.9 3.4 10.2 8.4 5.31 920 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 920 500 4.50 3.81 5.75 6.25 4(a) to 5.38 j 3.63 10.51 10.5 8,4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 21/2 (a) 't 3450 500 69.9 2.75 138 5.07 157 6.19 159 6.19 122 4.81 316 12.42 114 4.50 5.3 5.3 11.6 11.6 65 920 3450 69.9 129 157 157 122 316 114 5.3 5.3 920 500 3450 2.75 69.9 5.25 133 - 12.42 316 76.1 mm 6.25 159 4.81 122 4.56 116 11.6 - 5.3 3(a) to 12.42 t ---- I 5.31 12.6 11.6 1 920 500 3.50 5.31 6.50 6.50 4.81 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 1 12,42 6.25 1 15.3 12.5 100 3450 114.3 122 171 162 I 122 316 159 1 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. S 0 IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2010 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV K htauiicr 11.fl2 5; FLOW DATA Exaggerated for clarity CARBON STEEL PIPE - HOLE CUT PRODUCTS .1. .1. .0 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C, ,K Values: AP = Where: - P = Where: c2 Q = Flow (GPM) - K Q = Flow (m3/h) AP = Pressure Drop (psi) V AP = Pressure Drop (bar) Q = C x JEF C=FlowCoefflcient Q = K x /AP K = Flow Coefficient Equivalent Length of Outlet Size Schedule OUTLET SIZE (C 120)t FT JL 13tI1i) C,/Kv Values 1.11]i i3I:liii1i ½ 0.840 15 21.3 9.4 .-- 3/4 i 1.050 16 20 26.7 - - 13.7 1 1 1.315 21 - - 8.7 25 33 - 1.8 1 1/4 1.660 50 48 32 42.7 5½ 6 42.9 41.1 1 ½ 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.373 112 104 50 60.3 9 1 * 96 -- 119 89.1 150 - 21/2 2.875 65 73.0 20 121/2 102 - - 128.5 3.001) 76.1 MM 16 - 161 - 76.1 138.1 249 237 3 3.500 80 88.9 14 15 /2 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 1 343.6 Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0,165inJ4.2rnm. www.victaulic.com VIcTAULIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. X44 _Cta _U, ii ice 11.02 6 REV K CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Approval Agency Outlet Size A'. 21/2 - 6 2.875 - 6.625 400 400 400 290 232 I 362 65-150 730-1683 All 10,40 DF 2755 300 2755 2755 1999 290 1599 232 2496 21/2 -4 2.875 - 4.500 All 300 300 I 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 I 362 21/2 -4 2.875 - 4.500 All SF 300 300 300 290 232 65-100 73.0-114.3 6.625 4 10 2065 300 2065 300 2065 250 1999 290 1599 232 1 2496 I 362 6 150 168.3 6.625 2065 300 2065 300 1724 300 1999 1599 232 2496 362 6 290 150 168.3 8.625 34 3040 2065 400 2065 - 2065 1999 1599 145 2496 - 8 21/2 10,40 - 200 219.1 34 10 2755 300 - - - 1000 145 - 8 8.625 250 200 219.1 8.625 2065 300 1724 - 1000 145 - 8 34 3040 - 300 200 219.1 1 2065 1 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 67150mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vIcTAuLIc IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV K \ /' -C tauIicr 1102 7 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. I For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 A—C—ta—uho- VICTAULIC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2010 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. 11.02 K E\ 1 Pipe Clamps • Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line 133183) Size Range: 3/4 (20mm) thru 2 (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact ) tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a 1. pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. ØTOLCQ ® C bS LISTED S CPVC Pipe Size A B C Max. Hanger Spacing Fastener Hex Head Size Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/4 3/4" (20) 2 /16" (58.7) 1/32 (27.8) 1/16' (30.2) - 51/2 (1.67) /16' (7.9) 9 (4.1) 24-1 1" (25) 2/8' (66.7) 1/16' (33.3) 1/16' (30.2) 6 (1.83) /16 (7.9) 9 (4.1) 24_11/4 11/4 (32) 3' (76.2) 11/2' (38.1) 1/16' (30.2) 61/2 (1.98) /16 (7.9) 11 (5.0) 24_11/2 11/2 (40) 31/4 (82.5) 1/8' (42.3) 1/16 (30.2) 7 (2.13) /16' (7.9) 12 (5.4) 24.2 2" (50) 311/16" (93.7) 121/32 (43.6) 1/16' (30.2) 8 (2.44) /16' (7.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2' 140mm1 pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2" (40mm). Patent #5,344,108 B-Line by EX'N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" )15mm( thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily 44 installed around pipe. For hanger with non-captured nut order Fig. 200S. 7 (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in 7 _- hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig.200-1t0200-2 Conforms to Federal Specifications \MN-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size \\ Designed to meet or exceed requirements of Fig. 200C Fig. 200F Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. WtJ100 lbs. (kg) 200-1/2 1/2" (15) /8".16 31/8 (79.4) 2/8 (66.7) 11 (5.0) 200-/4 3/4" (20) /8'-16 31/8 (79.4) 21/2" (63.5) 11 (5.0) 200-1 1' (25) /8'-16 33/' (85.7) 2/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) /8".16 33/4' (94.0) 2/8' (73.0) 13 (5.9) 200-11/2 11/2" (40) /8"-16 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200-2 2' (50) /8"-16 41/2 (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) /8"-16 5/8 (142.9) 41/8" (104.7) 27 (12.3) 200-3 3' (75) /8"-16 5/8' (149.1) 4' (101.6) 29 (13.3) 200-31/2 31/2" (90) /8"-16 7/8 (187.3) 51/4' (133.3) 34 (15.6) 200-4 4' (100) /8"-16 7/8 (187.3) 5" (127.0) 35 (16.0) 200-5 5' (125) 1/2'-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2'-13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 13/8" (333.4) 8/4" (222.2) 136 (62.3) fl B Fig. 2001/2. 200./4 Fig. 200-21I2 to 200-8 Fig. 200 I Fig. 200S Pipe Hangers ®TOLCcT c®us USYD Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by T4J A Thread Size Part No. & Size Threads Per Inch Recommended Load Lbs. (kN) Approx. Wt./100 Ft. Lbs. (kg) ATR 1/4" x '1' 20 240 (1.07) 12 (5.44) AIR 3/8" x 'U 16 730 (3.24) 29 (13.15) ATR /2" x'1' 13 1350 (6.00) 53 (24.04) ATR /" x 'U 11 2160 (9.60) 89 (40.37) ATR 3/4" x '1' 10 3230 (14.31) 123 (55.79) ATR 7/8" x'L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog I Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ®TDLCcT • B32051 - Threaded Rod (right & left hand threads) Size Range: /8°16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°c) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish [1 Standard Design Load Thread Size Thread Length TL 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x /8'-16 21/2 (63.5) 730 (3.25) 572 (2.54) B3205-1/2 X '1' 1/2 13 21/2 (63.5) 1350 (6.00) 1057 (4.10) B3205-5/8 x '1' f8-11 21/2 (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x L /4-10 3 (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 x 1' /8'-9 31/2 (88.9) 4480 (19.93) - 3508 (15.60) For larger sizes consult full line pipe hanger catalog AIR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2"-6 rod in 10' )3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°cl Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. b--Line All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by E'l'N 94 Fire Protection Solutions - ----- .. .-- I SAMMYS® FOR WOOD E "No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drildriver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. (jWafth a video demonsvavon'\ www.itwbuildex.comJ #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Part #8114910 1/4" 8002957 GST 100 1/4 x1" 25 125 9 [ 1/4 8003957 GST 200 1/4x2 1760(Fir) - 25 5 3/8" 8007957 GST 10 1/4 xl 300 25 125 670 8008957 GST 20 1t4x2 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 2O SS 114x2 1760 (Fir) 850 25 125 3/8 8009925 GST 25-380 3/8x21/2 - 2113 (Fir) 1500 25 125 tL' 3/8" 8010957 GST 30 1/4x3 2060 (Fir) 1500 1475 25 125 3/8 - 8069925 GST30SS 114x3 2060 (Fe) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125 - -- 1/2 - 8015925 GST3 1/4x3 - 2275 (Fir) - 25 125 10105"If _ S MAM.FACTwED U.S.A. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 6~Affmlyg Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & 5" pipe I A * Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. -No pre-drilling required. Joi Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. OWah a video demonstration www.itwbuildex.comj V 1/4" 8019957 SWG 200 1/4x2" 1725 (Fir) 25 125 L_TT 1o57 . SWG10 1M 622 (Fir) 300 - 25 125 LL 3/8 8021957 SWG20 1/4x2" 1725 (Fir) 1050 25 125 SWG2OSS 4x2 1725(Fv) 850 25 125 - 3/8°" 8022925 SWG25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 #14 SW Red 3/8" 8023925 SWG3O - - 1/4x3" 1884 IFir) - 25 - 125 Nut Driver Part # 8114910 * May require pre-drilling; consult joist manufacturer. oo womim IWMIGLEN Eliminates distortion of threaded rod. Accommodates up to 3 '/2" x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. S XIIIIIIIIIIIIIII L Test Load FM Test Min _____ U Nut Driver 4 /<S" 3/8' 8139957 SH-GST2O 1/4x2" 1257 (Fir) 1050 1475 Part#8113910 —f-- - - ...... 3/8" 8269957 SH-GST/CST2O 5/16x1-3/4" 1 903 Dim Lumber 1500 1406@45°off vertical J Dim. Lumber I 903 Dim. Lumber . 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical L Dim. Lumber * May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part #8273910 25 125 25 125 25 125