HomeMy WebLinkAbout1964 KELLOGG AVE; ; AS000081; Permit11/3/21, 9:57 AM AS000081 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1964 KELLOGG AV Permit Type: SPRINK Parcel No: 2120930200 Lot #: 0 Reference No.: PC #: Project Title: FLOREXPO Permit No: AS00008I Status: ISSUED Applied 6/1/2000 Approved: 6/12/2000 Issued: 6/12/2000 Inspector: Applicant: Owner: JORKENLLC 1964 KELLOGG AV CARLSBAD CA Fees ($)J Add'l Fees ($) Total ($) Balance ($) 90J 0 90 0 1/1 Carlsbad Eire Department 990030 1635 Faraday Ave. re Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category.- Auto. Sprinkler, OH Date of Report: 06/06/2000 Reviewed by: Name: Grinnell Fire Prot. Address: 4223 Ponderosa Av Ste D City, State: San Diego CA 92123 Plan Checker: Job #: 990030 Job Name: FLOREXPO Bldg #: CB990369 Job Address: 1964 KELLOGG AV Ste. or Bldg. No. r Approved The item you have submitted for review has been approved. The approval is "SI based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. U Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID FD Job # 990030 FD File # ASocoo~( INDUSTRIAL FIRE SPRINKLER CO., INC. 2733 Via Orange Way, Suite 103, Spring Valley, CA HYDRAULIC CALCULATIONS COVER SHEET FLUREXPO - 2nd Floor Pendents WATER SUPPLY STATIC PRESSURE (psi) 99 RESIDUAL PRESSURE (psi) 94.5 RESIDUAL FLOW (gp) 1188 BOOSTER PUMPS 4- vQt (wiD Ayt- Uri SPRINKLERS MAXIMUMMUM SPACING OF SPRINKLERS (ft) 15 MAXIMUM SPACING OF SPRINKLER LINES (ft) 15 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .1 THIS SPRINKLER SYSTEM WILL DIVER A DENSITY OF .1 gpm/sq. ft. FOR A DESIGN AREA OF 1500 SQ. FT. OF FLCOR AREA THIS SYSTEM OPERATES AT A FLOW OF 388.80 gpm AT A PRESSURE OF 75.21 psi AT THE BASE OF THE RISER (REF. PT. 10) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 101 CAST IRON CEMENT LINED (150) 012 DYNA-FLOW 10 013 DYNA-THREAD-40 INDUSTRIAL FIRE SPRINKLER CO., INC. FLUREXPO - 2nd Floor Pendents PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: I ] TEST AREA 1 [ I TEST AREA 2 D<1 TEST AREA 3 C<I REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 207 5.60 27.00 31.00 30.63 208 5.60 27.00 29.11 27.02 209 5.60 27.00 27.88 24.79 210 5.60 27.00 25.83 21.28 211. 5.60 27.00 23.24 17.22 212 5.60 27.00 22.50 16.14 214 5.60 27.00 30.51 29.68 215 5.60 27.00 28.40 25.72 216 5.60 27.00 25.82 21.26 217 5.60 27.00 23,24 17,22 218 5.60 27.00 22.50 16.14 220 5.60 27.00 33.66 36.12 221 5.60 27.00 32.80 34.31 222 5.60 27.00 32.30 33.27 THE SPRINKLER SYSTEM FLOW IS THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS I THE INSIDE HOSE [ ] RACK SPKL1R' S. {)) YARD HYUr. FLOW IS THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS sWIIIAJUJ 100.00 gpm 0,100 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. Fr. 1 <--- STATIC PRESSURE 99.00 psi RESIDUAL PRESSURE 94.50 psi AT 1188.00 gpm TOTAL SYSTEM FLOW 488.80 gpm AVAILABLE PRESSURE 98.13 psi AT 488.80 gpm OPERATING PRESSURE 86.50 psi AT 488.80 gpm PRESSURE REMAINING 11.63 psi THE ABOVE RESULTS INCLUDE 10.00 psi FRICTION LOSS AT REF. PT. # [ BACKFLOW PREVENTER [1METER DETECTOR CHECK VALVE [ I OTHER DEVICE 2 FOR A INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXEO - 2nd Floor Pendents PAGE 2 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. T Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS EV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gprn) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 488.80 40.00 35 58.96 150 107 7.980 0.002 0.000 86.50 86.34 0.16 2 3 488.80 15.00 2222 69.18 140 101 7.980 0.002 0.000 86.34 76.18 10.16 3 4 488.80 30.00 2 19.65 150 107 7.980 0.002 0.000 76.18 76.10 0.08 4 5 388.80 25.00 0.00 150 107 6.090 0.004 0.000 76.10 76.00 0.10 5 6 388.80 90.00 2256 81.72 150 107 6.090 0.004 0.000 76.00 75.32 0.68 6 10 388.80 10.00 2 10.38 140 101 5.890 0.005 0.000 75.32 75.21 0.11 10 11 388.80 25.00 0.00 120 12 3.340 0.112 10.833 75.21 61.58 2.79 11 12 388.80 85.00 22 15.12 120 12 3.340 0.112 0.000 61.58 50.34 11.25 12 200 388.80 12.00 3 19.66 120 12 3.340 0.112 0.000 50.34 46.78 3.56 200 201 229.24 11.00 0.00 120 12 3.340 0.042 0.000 46.78 46.30 0.48 201 202 98.77 11.00 0.00 120 12 3.340 0.009 0.000 46.30 46.28 0.02 200 203 159.56 2.00 3 9.50 120 13 2.115 0.200 0.867 46.78 43.62 2.30 201 204 130.48 2.00 3 9.50 120 13 2.115 0.138 0.867 46.30 43.85 1.58 202 205 98.77 2.00 3 9.50 120 13 2.115 0.082 0.867 46.28 44.47 0.94 203 206 159.56 22.00 3 9.50 120 13 2.115 0.200 0.000 43.62 37.33 6.29 206 207 159.56 10.00 0.00 120 13 1.650 0.669 0.000 37.33 30.63 6.69 207 208 128.57 8.00 0.00 120 13 1.650 0.449 0.000 30.63 27.02 3.62 208 209 99.46 8.00 0.00 120 13 1.650 0.279 0.000 27.02 24.79 2.23 209 210 71.57 11.00 0.00 120 13 1.416 0.319 0.000 24.79 21.28 3.51 210 211 45.74 8.00 0.00 120 13 1.087 0.505 0.000 21.28 17.22 4.05 211 212 22.50 8.00 0.00 120 13 1.087 0.136 0.000 17.22 16.14 1.08 204 213 130.48 3.00 3 9.50 120 13 2.115 0.138 0.000 43.85 42.13 1.72 213 214 130.48 27.00 0.00 120 13 1.650 0.461 0.000 42.13 29.68 12.45 214 215 99.97 14.00 0.00 120 13 1.650 0.282 0.000 29.68 25.72 3.96 215 216 71.57 14.00 0.00 120 13 1.416 0.319 0.000 25.72 21.26 4.46 216 217 45.74 8.00 0.00 120 13 1.087 0.505 0.000 21.26 17.22 4.04 217 218- 22.50 8.00 0.00 120 13 1.087 0.136 0.000 17.22 16.14 1.08 205 219 98.77 5.00 3 9.50 120 13 2.115 0.082 0.000 44.47 43.28 1.19 219 220 98.77 26.00 -0 0.00 120 13 1.650 0.275 0.000 43.28 36.12 7.16 220 221 65.11 14.00 -0 0.00 120 13 1.650 0.127 0.000 36.12 34.31 1.81 221 222 32.30 14.00 -0 0.00 120 13 1.416 0.073 0.000 34.31 33.27 1.04 A MAX. VOCITY OF 23.93 ft./sec. OCCURS BETWEEN REF. PT. 206 AND 207 Sprinkler-CALC Release 6.3 By Walsh Engineering Inc. North Kingstown R.I. U.S.A. coN::cr NAME FO 1? FL X Po - SHEET OF z NOZZLI IDINT AND (.00ATION FLOW IN C.P.M. PIPI SIZI Pin AND DIVICLS Q I PIPE UNCT4 LOSS P,$.$./FQQT PRESSURE $UhO4ARY NORMAL PLSSUE cc - NOT 14 --6 L I IZ Pt IC1I Pt E1 F 7 Pe 7Z Pv. Q22.S N / Pr q L Pt 1 09 Pt Pn F .PO Pv r N L Pt Pt Pe Pv Q 1' Pf Pr I Pt Pt Pn F Pe Pv T Pf — L Pt Pt Pr, F Pe Pv Q T N I Pt Pt Pr, F Pe Pv T Pf q I Pt Pt Pn ______ -- F Pc Pv T Pf I Pt Pt Pn F Pe Pv Q T N • q I Pt Pt - Pe. Pv Q I Pf Pn • ___ q I' Pt Pt F Pe Pv Q ___ I N Pr q I Pt Pt Pn F Pe Pv _______ ____ I Pf ~Pl- - __ Lj FL (p -2 345X@PJL INFO STATUS USTATUS DEVICE=ON USTATUS PAGE=ON @PJL @PJL USTATUS TIMED INDUSTRIAL FIRE SPRINKLER CO., INC. 2733 Via Orange Way, Suite 103, Spring Valley, CA HYDRAULIC CALCULATIONS COVER SHEET F1REXPO - Grid Shift STATIC PRESSURE (psi) RESIDUAL PRESSURE (psi) RESIDUAL FLOW (gpm) WATER SUPPLY 99 94.5 1188 BOOSTER PUMPS SPRINKLERS MAXIMUM SPACING OF SPRINKLERS (ft) 8 MAXIMUM SPACING OF SPRINKLER LINES (ft) 15 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .2 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .2 gpm/sq. ft. FOR A DESIGN AREA OF 1500 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 404.12 gpm AT A PRESSURE OF 77.90 psi AT THE BASE OF THE RISER (REF. PT. 10) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 101 CAST IRON CEMENT LINED (150) 01.2 DYNA-FLOW 10 013 DYN7-\-THR.EAD-40 FLOREXPO - 113 .05 107.10 101.15 P 95.20 R 89.25 E 83.30 S 77.35 S 71.40 U 65.45 R 59.50 E 53.55 (psi) 47.60 41.65 35.70 29.75 23.80 17.85 11.90 5.95 0.00 345X@PJL INFO STATUS @PJL USTATUS DEVICE=ON @PJL USTATUS PAGE=ON @PJL USTATUS TIMED INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXO - Grid Shift PAGE 1 --------------------------------------------------------------------------------------------- SPRINKLER SYSTEM ANALYSIS TO SHOW THE MAXIMUM DENSITY AVAILABLE WITH ZERO PRESSURE REMAINING --------------------------------------------------------------------------------------------- THE FOLLOWING SPRINKLERS ARE OPERATING IN: [] TEST AREA 1 [ I TEST AREA 2 [ I TEST AREA 3 [XI REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. yr. K ELEV. FLOW PRESSURE ft gpm psi 132 5.60 27.00 26.61 22.58 133 5.60 27.00 26.57 22.50 134 5.60 27.00 25.74 21.13 135 5.60 27.00 25.70 21.05 136 5.60 27.00 25.48 20.71 137 5.60 27.00 25.44 20.63 138 5.60 27.00 25.48 20.70 139 5.60 27.00 25.43 20.62 140 5.60 27.00 25.69 21.03 141 5.60 27.00 25.72 21.10 142 5.60 27.00 26.54 22.45 143 5.60 27.00 26.50 22.39 146 5.60 27.00 29.49 27.72 147 5.60 27.00 29.21 27.20 148 5.60 27.00 29.21 27.20 149 5.60 27.00 29.45 27.65 THE SPRINKLER SYSTEM FLOW IS THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO, 1 IS THE INSIDE HOSE [ I RACK SPKLR' S. [XI YARD HYEIT. FLOW IS THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 428.25 gpm [iWIIOzj 250.00 gpm 0.212 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. yr. 1 <--- STATIC PRESSURE 99.00 psi RESIDUAL PRESSURE 94.50 psi AT 1188.00 gpm ]UI'AL SYSTEM FLOW 678.25 gpm AVAILABLE PRESSURE 97.41 psi AT 678.25 gpm OPERATING PRESSURE 97.41 psi AT 678.25 gpm PRESSURE REMAINING 0.00 psi THE ABOVE RESULTS INCLUDE 10.00 psi FRICTION LOSS AT REF. yr. # 2 FOR A L)(I EACKFLDW PREVENTER [ ] METER INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXO - Grid Shift PAGE 2 --------------------------------------------------------------------------------------------- HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: TEST AREA 1 [ I TEST AREA 2 [ I TEST AREA 3 [XI REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 132 5.60 27.00 25.11 20.11 133 5.60 27.00 25.07 20.04 134 5.60 27.00 24.28 18.80 135 5.60 27.00 24.24 18.74 136, 5.60 27.00 24.04 18.43 137 5.60 27.00 24.00 18.37 138 5.60 27.00 24.04 18.43 139 5.60 27.00 24.00 18.37 140 5.60 27.00 24.24 18.74 141 5.60 27.00 24.26 18.77 142 5.60 27.00 25.03 19.98 143 5.60 27.00 25.00 19.93 146 5.60 27.00 27.85 24.73 147 5.60 27.00 27.58 24.25 148 5.60 27.00 27.57 24.24 149 5.60 27.00 27.80 24.64 THE SPRINKLER SYSTEM FLOW IS THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS THE INSIDE HOSE [ I RACK SPKLR' S. LX YARD HYDT. FLOW IS THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS THE FOLLOWING PRESSURES & FLOWS OCCUR AT REF. PT. 1 STATIC PRESSURE 99.00 psi RESIDUAL PRESSURE 94.50 psi AT 1188.00 gpm TOTAL SYSTEM FLOW 654.12 gpm AVAILABLE PRESSURE 97.51 psi AT 654.12 gpm OPERATING PRESSURE 89.55 psi AT 654.12 gpm PRESSURE REMAINING 7.96 psi 404.12 gpm [IW•IIej 250.00 gpm 0.200 gpm/sq. ft. THE ABOVE RESULTS INCLUDE 10.00 psi FRICTION LOSS AT REF. PT . # 2 FOR A t)j BACKFWW PREVENTER { ] METER I DETECTOR CHECK VALVE { ] OTHER DEVICE INDUSTRIAL FIRE SPRINKLER CO., INC. FLDREXPO - Grid Shift PAGE 3 --------------------------------------------------------------------------------------------- FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3="T'/Cross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO'. DI FF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 654.12 40.00 35 58.96 150 107 7.980 0.003 0.000 89.55 89.27 0.28 2 3 654.12 15.00 2222 69.18 140 101 7.980 0.003 0.000 89.27 79.00 10.27 3 4 654.12 30.00 2 19.65 150 107 7.980 0.003 0.000 79.00 78.86 0.14 4 5 404.12 25.00 0.00 150 107 6.090 0.004 0.000 78.86 78.76 0.11 5 6 404.12 90.00 2256 81.72 150 107 6.090 0.004 0.000 78.76 78.02 0.74 6 10 404.12 10.00 2 10.38 140 101 5.890 0.006 0.000 78.02 77.90 0.12 10 11 404.12 25.00 0.00 120 12 3.340 0.121 10.833 77.90 64.05 3.02 11 12 404.12 85.00 22 15.12 120 12 3.340 0.121 0.000 64.05 51.97 12.08 12 13 404.12 2.00 3 19.66 120 12 3.340 0.121 0.000 51.97 49.36 2.61 13 14 378.08 12.00 0.00 120 12 3.340 0.107 0.000 49.36 48.08 1.28 14 15 355.07 12.00 0.00 120 12 3.340 0.095 0.000 48.08 46.94 1.14 15 16 334.92 12.00 0.00 120 12 3.340 0.085 0.000 46.94 45.92 1.02 16 17 317.42 13.00 0.00 120 12 3.340 0.077 0.000 45.92 44.92 1.00 17 18 302.54 14.00 0.00 120 12 3.340 0.071 0.000 44.92 43.94 0.98 18 19 290.21 14.00 0.00 120 12 3.340 0.065 0.000 43.94 43.02 0.91 19 20 280.16 14.00 0.00 120 12 3.340 0.061 0.000 43.02 42.16 0.86 20 21 272.10 14.00 0.00 120 12 3.340 0.058 0.000 42.16 41.35 0.81 21 22 265.71 14.00 0.00 120 12 3.340 0.056 0.000 41.35 40.57 0.78 22 23 260.64 14.00 0.00 120 12 3.340 0.054 0.000 40.57 39.82 0.75 23 24 256.43 14.00 0.00 120 12 3.340 0.052 0.000 39.82 39.10 0.73 24 25 252.53 14.00 0.00 120 12 3.340 0.051 0.000 39.10 38.39 0.71 25 26 248.30 14.00 0.00 120 12 3.340 0.049 0.000 38.39 37.70 0,69 26 27 243.17 14.00 0.00 120 12 3.340 0.047 0.000 37.70 37.04 0.66 27 28 236.68 14.00 0.00 120 12 3.340 0.045 0.000 37.04 36.42 0.63 28 29 228.37 13.00 0.00 120 12 3.340 0.042 0.000 36.42 35.87 0.55 29 30 171.95 12.00 0.00 120 12 3.340 0.025 0.000 35.87 35.55 0.32 30 31. 97.09 12.00 0.00 120 12 3.340 0.009 0.000 35.55 35.45 0.10 31 32 22.32 12.00 0.00 120 12 3.340 0.001 0.000 35.45 35.44 0.01 32 33 10.26 12.00 0.00 120 12 3.340 0.000 0.000 35.44 35.44 0.00 40 41 26.04 12.00 0.00 120 12 2.731 0.002 0.000 41.54 41.51 0.03 41 42 49.05 12.00 0.00 120 12 2.731 0.006 0.000 41.51 41.42 0.09 42 43 69.20 12.00 0.00 120 12 2.731 0.012 0.000 41.42 41.27 0.15 43 44 86.70 13.00 0.00 120 12 2.731 0.019 0.000 41.27 40.92 0.35 44 45 101.58 14.00 0.00 120 12 2.731 0.025 0.000 40.92 40.57 0.35 45 46 113.91 14.00 0.00 120 12 2.731 0.031 .0.000 40.57 40.14 0.43 46 47 123.96 14.00 0.00 120 12 2.731 0.036 0.000 40.14 39.63 0.50 47 48 132.02 14.00 0.00 120 12 2,731 0.041 0.000 39.63 39.07 0.57 48 49 138.41 14.00 0.00 120 12 2.731 0.044 0.000 39.07 38,45 0.62 49 50 143.48 14.00 0.00 120 12 2.731 0.047 0.000 38.45 37.78 0.66 50 51 147.69 14.00 0.00 120 12 2.731 0.050 0.000 37.78 37.09 0.70 51 52 151.60 14.00 0.00 120 12 2.731 0.052 0.000 37.09 36.35 0.73 52 53 155.82 14.00 0.00 120 12 2.731 0.055 0.000 36.35 35.58 0.77 INDUSTRIAL FIRE SPRINKLER CO., INC. FLOPEXPO - Grid Shift PAGE 4 --------------------------------------------------------------------------------------------- FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS E)QV. H-W PIPE DIA. ERIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 53 54 160.95 14.00 0.00 120 12 2.731 0.058 0.000 35.58 34.77 0.82 54 55 167.44 14.00 0.00 120 12 2.731 0.063 0.000 34.77 33.88 0.88 55 56 175.75 13.00 0.00 120 12 2.731 0.069 0.000 33.88 32.99 0.89 56 57 121.37 12.00 0.00 120 12 2.731 0.035 0.000 32.99 32.64 0.35 57 58 49.48 12.00 0.00 120 12 2.731 0.007 0.000 32.64 32.56 0.08 58 59 -22.32 6.00 0.00 120 12 2.731 0.002 0.000 32.56 32.56 -0.01 13 70 26.04 5.00 33 12.00 120 13 1.416 0.049 0.867 49.36 47.66 0.83 14 71 23.01 5.00 33 12.00 120 13 1.416 0.039 0.867 48.08 46.55 0.66 15 72 20.15 5.00 33 12.00 120 13 1.416 0.031 0.867 46.94 45.56 0.52 16 73 17.50 5.00 33 12.00 120 13 1.416 0.024 0.867 45.92 44.65 0.40 17 74 14.88 5.00 33 12.00 120 13 1.416 0.017 0.867 44.92 43.75 0.30 18 75 12.33 5.00 33 12.00 120 13 1.416 0.012 0.867 43.94 42.86 0.21 19 76 10.05 5.00 33 12.00 120 13 1.416 0.008 0.867 43.02 42.01 0.14 20 77 8.06 5.00 33 12.00 120 13 1.416 0.006 0.867 42.16 41.20 0.10 21 78 6.39 5.00 33 12.00 120 13 1.416 0.004 0.867 41.35 40.42 0.06 22 79 5.07 5.00 33 12.00 120 13 1.416 0.002 0.867 40.57 39.67 0.04 23 80 4.21 5.00 33 12.00 120 13 1.416 0.002 0.867 39.82 38.93 0.03 24 81 3.90 5.00 33 12.00 120 13 1.416 0.001 0.867 39.10 38.21 0.02 25 82 4.23 5.00 33 12.00 120 13 1.416 0.002 0.867 38.39 37.49 0.03 26 83 5.13 5.00 33 12.00 120 13 1.416 0.002 0.867 37.70 36.80 0.04 27 84 6.49 5.00 33 12.00 120 13 1.416 0.004 0.867 37.04 36.11 0.06 28 85 8.32 5.00 33 12.00 120 13 1.416 0.006 0.867 36.42 35.45 0.10 29 86 56.42 5.00 33 12.00 120 13 1.416 0.206 0.867 35.87 31.51 3.49 30 87 74.86 5.00 33 12.00 120 13 1.416 0.347 0.867 35.55 28.78 5.90 31 88 74.77 5.00 33 12.00 120 13 1.416 0.346 0.867 35.45 28.69 5.89 32 89 12.07 5.00 33 12.00 120 13 1.416 0.012 0.867 35.44 34.37 0.20 33 90 10.26 5.00 33 12.00 120 13 1.416 0.009 0.867 35.44 34.42 0.15 40 100 -26.04 3.00 33 12.00 120 13 1.416 0.049 -0.867 41.54 43.14 -0.74 41 101 -23.01 3.00 33 12.00 120 13 1.416 0.039 -0.867 41.51 42.96 -0.59 42 102 -20.15 3.00 33 12.00 120 13 1.416 0.031 -0.867 41.42 42.75 -0.46 43 103 -17.50 3.00 33 12.00 120 13 1.416 0.024 -0.867 41.27 42.49 -0.35 44 104 -14.88 3.00 33 12.00 120 13 1.416 0.017 -0.867 40.92 42.15 -0.37 45 105 -12.33 3.00 33 12.00 120 13 1.416 0.012 -0.867 40.57 41.62 -0.18 46 106 -10.05 3.00 33 12.00 120 13 1.416 0.008 -0.867 40.14 41.13 -0.13 47 107 -8.06 3.00 33 12.00 120 13 1.416 0.006 -0.867 39.63 40.58 -0.08 48 108 -6.39 3.00 33 12.00 120 13 1.416 0.004 -0.867 39.07 39.99 -0.05 49 109 -5.07 3.00 33 12.00 120 13 1.416 0.002 -0.867 38.45 39.3 -0.04 50 110 -4.21 3.00 33 12.00 120 13 1.416 0.002 -0.867 37.78 38.68 -0.03 51 111 -3.90 3.00 33 12.00 120 13 1.416 0.001 -0.867 37.09 37.98 -0.02 52 112 -4.23 3.00 33 12.00 120 13 1.416 0.002 -0.867 36.35 37.25 -0.03 53 113 -5.13 3.00 33 12.00 120 13 1.416 0.002 -0.867 35.58 36.49 -0.04 54 114 -6.49 3.00 33 12.00 120 13 1.416 0.004 -0.867 34.77 35.69 -0.06 55 115 -8.32 3.00 33 12.00 120 13 1.416 0.006 -0.867 33.88 34.84 -0.09 INDUSTRIAL FIRE SPRINKE1ER CO., INC. FDJREO - Grid Shift PAGE 5 --------------------------------------------------------------------------------------------- FIITING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FROM TO FID.AI PIPE FITS DQV. H-W PIPE DIA. FRIC. ELEV, FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 56 116 54.38 3.00 33 12,00 120 13 1.416 0.192 -0.867 32.99 30.98 2.88 57 117 71,89 3.00 33 12.00 120 13 1.416 0.322 -0.867 32.64 28.67 4.83 58 118 71.81 3.00 33 12.00 120 13 1.416 0.321 -0.867 32.56 28.60 4.82 59 119 -22.32 3.00 33 19.00 120 13 2.115 0.005 -0.867 32.56 33.55 -0.12 70 100 26.04 92.00 0.00 120 13 1.416 0.049 0.000 47.66 43.14 4.52 71 101 23.01 92.00 0.00 120 13 1.416 0.039 0.000 46.55 42.96 3.59 72 102 20.15 92.00 0.00 120 13 1.416 0.031 0.000 45.56 42.75 2.81 73 103 17.50 92.00 0.00 120 13 1.416 0.024 0.000 44.65 42.49 2.16 74 104 14.88 92.00 0.00 120 13 1.416 0.017 0.000 43.75 42.15 1.60 75 105 12.33 92.00 0.00 120 13 1.416 0.012 0.000 42.86 41.62 1.24 76 106 10.05 92.00 0.00 120 13 1.416 0.008 0.000 42.01 41.13 0.88 77 107 8.06 92.00 0.00 120 13 1.416 0.006 0.000 41.20 40.58 0.62 78 108 6.39 92.00 0.00 120 13 1.416 0.004 0.000 40.42 39.99 0.44 79 109 5.07 92.00 0.00 120 13 1.416 0.002 0.000 39.67 39.35 0.32, 80 110 4.21 92.00 0.00 120 13 1.416 0.002 0.000 38.93 38.68 0.25 81 111 3.90 92.00 0.00 120 13 1.416 0.001 0.000 38.21 37.98 0.23 82 112 4.23 92.00 0.00 120 13 1.416 0.002 0.000 37.49 37.25 0.25 83 113 5.13 92.00 0.00 120 13 1.416 0.002 0.000 36.80 36.49 0.31 84 114 6.49 92.00 0.00 120 13 1.416 0,004 0.000 36.11 35.69 0.43 85 115 8.32 92.00 0.00 120 13 1.416 0.006 0.000 35.45 34.84 0.61 86 146 56.42 33.00 0.00 120 13 1.416 0.206 0.000 31.51 24.73 6.78 146 147 28.56 8.00 0.00 120 13 1.416 0.058 0.000 24.73 24.25 0.48 147 148 0.99 8.00 0.00 120 13 1.416 0.000 0.000 24.25 24.24 0.01 148 149 26.58 8.00 0.00 120 13 1.416 0.051 0.000 24.24 24.64 -0.40 149 116 -54.38 33.00 0.00 120 13 1.416 0,192 0.000 24.64 30.98 -6.34 87 130 74.86 17.00 0.00 120 13 1.416 0.347 0.000 28.78 22.88 5.90 88 187- 74.77 9.00 0.00 120 13 1.416 0.346 0.000 28.69 25.58 3.12 187 131 74.77 8.00 0.00 120 13 1.416 0.346 0.000 25.58 22.81 2.77 130 132 74.86 8.00 0.00 120 13 1.416 0.347 0.000 22.88 20.11 2.78 131 133 74.77 8.00 0.00 120 13 1.416 0.346 0.000 22.81 20.04 2.77 132 134 49.75 8.00 0.00 120 13 1.416 0.163 0.000 20.11 18.80 1.31 133 135 49.70 8.00 0.00 120 13 1.416 0.163 0.000 20.04 18.74 1.30 134 136 25.47 8.00 0.00 '120 13 1.416 0.047 0.000 18.80 18.43 0.37 135 137 25.46 8.00 0.00 120 13 1.416 0.047 0.000 1874 18.37 0.37 136 138 1.43 8.00 0.00 120 13 1.416 0.000 0.000 18.43 18.43 -0.00 137 139 1.46 8.00 0.00 120 13 1.416 0.000 0.000 18.37 18.37 0.00 138 140 -22.62 8.00 0.00 120 13 1.416 0.038 0.000 18.43 18.74 -0.31 139 141 -22.54 8.00 0.00 120 13 1.416 0.038 0.000 18.37 18.77 -0.40 140 142 -46.86 8.00 0.00 120 13 1.416 0.146 0.000 18.74 19.98 -1.24 141 143 -46.80 8.00 0.00 120 13 1.416 0.145 0.000 18.77 19,93 -1.16 142 144 -71.89 8.00 0.00 120 13 1.416 0.322 0.000 19.98 22.56 -2.58 143 145 -71.81 8.00 0.00 120 13 1.416 0.321 0.000 19.93 22.50 -2.57 144 117 -71.89 19.00 0.00 120 13 1.416 0.322 0.000 22.56 28.67 -6.12 INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXPO - Grid Shift PAGE 6 --------------------------------------------------------------------------------------------- FITI'ING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS DQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 145 118 -71.81 19.00 0.00 120 13 1.416 0.321 0.000 22.50 28.60 -6.10 89 170 12.07 9.00 0.00 120 13 1.416 0.012 0.000 34.37 34.26 0.11 170 171 12.07 8.00 0.00 120 13 1.416 0.012 0.000 34.26 34.17 0.09 171 172 12.07 8.00 0.00 120 13 1.416 0.012 0.000 34.17 34.08 0.09 172 173 12.07 8.00 0.00 120 13 1.416 0.012 0.000 34.08 33.98 0.09 173 174 12.07 8.00 0.00 120 13 1.416 0.012 0.000 33.98 33.98 0.01 174 175 12.07 8.00 0.00 120 13 1.416 0.012 0.000 33.98 33.88 0.09 175 176 12.07 1.00 0.00 120 13 1.416 0.012 0.000 33.88 33.87 0.01 176 177 12.07 4.00 0.00 120 13 1.416 0.012 0.000 33.87 33.82 0.05 90 178 10.26 9.00 0.00 120 13 1.416 0.009 0.000 34.42 34.34 0.08 178 179 10.26 8.00 0.00 120 13 1.416 0.009 0.000 34.34 34.27 0.07 179 180 10.26 7.00 -0 0.00 120 13 1.416 0.009 0.000 34.27 34.21 0.06 180 181 10.26 1.00 -0 0.00 120 13 1.416 0.009 0.000 34.21 34.29 -0.08 181 182 10.26 14.00 22 4.98 120 13 1.416 0.009 0.000 34.29 34.12 0.17 182 183 10.26 8.00 -0 0.00 120 13 1.416 0.009 0.000 34.12 34.05 0.07 183 184 10.26 8.00 -0 0.00 120 13 1.416 0.009 0.000 34.05 33.98 0.07 184 177 10.26 10.00 23 8.49 120 13 1.416 0.009 0.000 33.98 33.82 0.16 177 119 22.32 45.00 22 7.82 120 13 2,115 0.005 0.000 33.82 33.55 0.28 182 185 0.00 1.50 3 4.99 120 13 1.087 0.000 0.000 34.12 34.12 0.00 183 186 0.00 1.50 3 4.99 120 13 1.087 0.000 0.000 34.05 34.05 0.00 A MAX- VELOCITY OF 15.25 ft. /sec. OCCURS BETWEEN REF. PT. 130 AND 132 16 INDUSTRIAL FIRE SPRINKLER CO., INC. F1OREXFO - Grid Shift PAGE 7 --------------------------------------------------------------------------------------------- SUMMARY OF REMOTE DESIGN AREA SEARCH ----------------------------------------------------------------------------- The design area PRECDING the remote area requires the following pressures and flows at Ref. Pt. 1 'ICJrAL SYSTEM FLOW 653.34 gpm AVAILABLE PRESSURE 97.51 psi OPERATING PRESSURE 88.87 psi PRESSURE REMAINING 8.64 psi THE REMOTE AREA requires the following pressures and flows at Ref. Pt. 1 TOTAL SYSTEM FLOW 654.12 gpm AVAILABLE PRESSURE 97.51 psi OPERATING PRESSURE 89.55 psi PRESSURE REMAINING 7.96 psi The design area FOLLOWING the remote area requires the following pressures and flows at Ref. Pt. 1 TOTAL SYSTEM FLOW 653.86 gpm AVAILABLE PRESSURE 97.51 psi OPERATING. PRESSURE 89.30 psi PRESSURE REMAINING 8.21 psi Sprinkler-CALC Release 6.3 By Walsh Engineering Inc. North Kingstown R. I. U.S.A. INDUSTRIAL FIRE SPRINKLER CO., INC. 2733 Via Orange Way, Suite 103, Spring Valley, CA HYDRAULIC CALCULATIONS COVER SHEET FLOREXPO - Grid @ Angled Wall WATER SUPPLY STATIC PRESSURE (psi) 99 RESIDUAL PRESSURE (psi) 94.5 RESIDUAL FLOW (gpm) 1188 BOOSTER PUMPS SPRINKLERS MAXIMUM SPACING OF SPRINKLERS (ft) 8 MAXIMUM SPACING OF SPRINKLER LINES (ft) 14 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .2 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .2 gpm/sq. ft. FOR A DESIGN AREA OF 1500 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 430.48 gpm AT A PRESSURE OF 79.67 psi AT THE EASE OF THE RISER (REF. PT. 10) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 101 CAST IRON CEMENT LINED (150) 012 DYNA-FLOW 10 013 DYNA-THREAD-40 FLOREXPO - 113.05 107.10 101.15 P 95.20 R 89.25 E 83.30 S 77.35 S 71.40 U 65.45 R 59.50 E 53.55 (psi) 47.60 41.65 35.70 29.75 23.80 17.85 11.90 5.95 0.00 345X@PJL INFO STATUS @PJL USTATUS DEVICE=ON @PJL USTATUS PAGE=ON @PJL USTATUS TIMED INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXPO - Grid © Angled Wall PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: I 'lEST AREA 1 )c'] TEST AREA 2 [ ] TEST AREA 3 [] PEIvDTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 170 5.60 27.00 25.55 20.81 171 5.60 27.00 24.55 19.22 172 5.60 27.00 24.21 18.69 173 5.60 27.00 24.20 18.67 174 5.60 27.00 24.34 18.89 176 5.60 27.00 25.04 19.99 178 5.60 27.00 24.83 19.66 179 5.60 27.00 23.64 17.81 181 5.60 27.00 23,16 17.10 184 5.60 27.00 23.41 17.48 185 5.60 27.00 22.40 16.00 186 5.60 27.00 22.44 16.05 187 5.60 27.00 25.05 20.00 131 5.60 27.00 23.85 18.14 133 5.60 27.00 23.36 17.41 135 5.60 27.00 23.29 17.30 137 5.60 27.00 23.35 17.39 139 5.60 27.00 23.80 18.05 THE SPRINKLER SYSTEM FLOW IS THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS I THE INSIDE HOSE [ ] RACK SPKLR' S. I] YARD HYDr. FLOW IS THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 430.48 gpm [IWSISN!J] 250.00 gpm 0.200 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. PT. 1 <--- STATIC PRESSURE 99.00 psi RESIDUAL PRESSURE 94.50 psi AT 1188.00 gpm TOTAL SYSTEM FLOW 680.48 gpm AVAILABLE PRESSURE 97.40 psi AT 680.48 gpm OPERATING PRESSURE 91.48 psi AT 680.48 gpm PRESSURE REMAINING 5.92 psi THE ABOVE RESULTS INCLUDE 10.00 psi FRICTION LOSS AT REF. PT. r)(] BACKFLOW. PREVENTER [ ] 4EV DETECTOR CHECK VALVE [ ] OTHER DEVICE 2 FOR A INDUSTRIAL FIRE SPRINKLER CO., INC. FLOREXPO - Grid @ Angled Wall FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H -W PIPE DIA. FR IC. ELEV. FROM TO DIFF (gpm) (ft) (ft.) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 680.48 40.00 35 58.96 150 107 7.980 0.003 0.000 91.48 91.18 0.30 2 3 680.48 15.00 2222 69.18 140 101 7.980 0.003 0.000 91.18 80.89 10.29 3 4 680.48 30.00 2 19.65 150 107 7.980 0.003 0.000 80.89 80.74 0.15 4 5 430.48 25.00 0.00 150 107 6.090 0.005 0.000 80.74 80.62 0.12 5 6 430.48 90.00 2256 81.72 150 107 6.090 0.005 0.000 80.62 79.80 0.83 6 10 430.48 10.00 2 10.38 140 101 5.890 0.006 0.000 79.80 79.67 0.13 10 11 430.48 25.00 0.00 120 12 3.340 0.136 10.833 79.67 65.44 3.39 11 12 430.48 85.00 22 15.12 120 12 3.340 0.136 0.000 65.44 51.86 13,58 12 13 430.48 2.00 3 19.66 120 12 3.340 0.136 0.000 51.86 48.92 2.94 13 14 402.84 12.00 0.00 120 12 3.340 0.120 0.000 48.92 47.48 1.44 14 15 378.44 12.00 0.00 120 12 3.340 0.107 0.000 47.48 46.20 1.28 15 16 357.05 12.00 0.00 120 12 3.340 0.096 0.000 46.20 45.05 1.15 16 17 338.48 13.00 0.00 120 12 3.340 0.087 0.000 45.05 43.92 1.13 17 18 322.68 14.00 0.00 120 12 3.340 0.080 0.000 43.92 42.81 1.11 18 19 309.61 14.00 0.00 120 12 3.340 0.074 0.000 42.81 41.79 1.02 19 20 298.99 14.00 0.00 120 12 3.340 0.069 0.000 41.79 40.82 0.97 20 21 290.56 14.00 0.00 120 12 3.340 0.065 0.000 40.82 39.90 0.92 21 22 284.04 14.00 0.00 120 12 3.340 0.063 0,000 39.90 39.02 0.88 22 23 279,12 14.00 0.00 120 12 3.340 0.061 0.000 39.02 p8.17 0.85 23 24 275.50 14.00 0.00 120 12 3.340 0.059 0.000 38.17 37.34 0.83 24 25 272,83 14,00 0.00 120 12 3.340 0.058 0.000 37.34 36.52 0.82 25 26 270.68 14.00 0.00 120 12 3.340 0.057 0.000 36.52 35.72 0.80 26 27 268.46 14.00 0.00 120 12 3.340 0.057 0.000 35.72 34.93 0,79 27 28 265.59 14.00 0.00 120 12 3.340 0.055 0.000 34.93 34.15 0.78 28 29 261.68 13.00 0.00 120 12 3.340 0.054 0.000 34.15 33.45 0.70 29 30 256.42 12.00 0.00 120 12 3.340 0.052 0.000 33.45 32.83 0.62 30 31- 249.70 12.00 0.00 120 12 3.340 0.049 0.000 32.83 32.23 0.59 31 32 164.90 12.00 0.00 120 12 3.340 0.023 0.000 32.23 31.95 0.29 32 33 84.61 12.00 0.00 120 12 3.340 0.007 0.000 31.95 31.85 0.10 40 41 27.63 12.00 0.00 120 12 2.731 0.002 0.000 40.39 40.35 0.04 41 42 52.04 12.00 0.00 120 12 2.731 0.007 0.000 40.35 40.24 0.11 42 43 73.42 12.00 0.00 120 12 2.731 0.014 0.000 40.24 40.06 0.18 43 44 92.00 13.00 0.00 120 12 2.731 0.021 0.000 40.06 39,78 0.29 44 45 107.80 14.00 0.00 120 12 2.731 0.028 0.000 39.78 39.38 0.40 45 46 120.87 14.00 0.00 120 12 2.731 0.034 0.000 39.38 38.87 0.51 46 47 131.49 14.00 0.00 120 12 2.731 0.040 0.000 38.87 38.30 0.56 47 48 139.92 14.00 0.00 120 12 2.731 0.045 0.000 38.30 37.67 0.63 48 49 146.43 14.00 0.00 120 12 2.731 0.049 0.000 37.67 36.98 0.69 49 50 151.35 14.00 0.00 120 12 2.731 0.052 0.000 36.98 36.25 0.73 50 51 154.98 14.00 0.00 120 12 2.731 0.055 0.000 36.25 35.49 0.76 51 52 157.64 14.00 0.00 120 12 2.731 0.056 0.000 35.49 34.70 0.79 52 53 159.80 14.00 0.00 120 12 2.731 0.058 0.000 34.70 33.90 0.81 INDUSTRIAL FIRE SPRINKLER CO., INC. DREXPO - Grid @ Angled Wall PAGE 3 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3=T'/Cross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FR4 TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpr) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 53 54 162.02 14.00 0.00 120 12 2.731 0.059 0.000 33.90 33.07 0.83 54 55 164.89 14.00 0.00 120 12 2.731 0.061 0.000 33.07 32.21 0.86 55 56 168.80 13.00 0.00 120 12 2.731 0.064 0.000 32.21 31.38 0.83 56 57 174.06 12.00 0.00 120 12 2.731 0,068 0.000 31.38 30.57 0181 57 58 180.78 12.00 0.00 120 12 2.731 0.072 0.000 30.57 29.70 0.87 58 59 122.87 6.00 0.00 120 12 2.731 0.035 0.000 29.70 29.49 0.21 13 70 27.63 5.00 33 12.00 120 13 1.416 0.055 0.867 48.92 47.13 0.93 14 71 24.40 5.00 33 12.00 120 13 1.416 0.044 0.867 47.48 45.88 0.74 15 72 21.39 5.00 33 12.00 120 13 1.416 0.034 0.867 46.20 44.76 0.58 16 73 18.57 5.00 33 12.00 120 13 1.416 0.026 0.867 4505 43.74 0.45 17 74 15.80 5.00 33 12.00 120 13 1.416 0.019 0.867 43.92 42.72 0.33 18 75 13.07 5.00 33 12.00 120 13 1.416 0.014 0.867 42.81 41.71 0.23 19 76 10.62 5.00 33 12.00 120 13 1.416 0.009 0.867 41.79 40.76 0.16 20 77 8.43 5.00 33 12.00 120 13 1.416 0.006 0.867 40.82 39.85 0.10 21 78 6.52 5.00 33 12.00 120 13 1.416 0.004 0.867 39.90 38.97 0.06 22 79 4.92 5.00 33 12.00 120 13 1.416 0.002 0.867 39.02 38.12 0.04 23 80 3.63 5.00 33 12.00 120 13 1.416 0.001 0.867 38.17 37.28 0.02 24 81 2.66 5.00 33 12.00 120 13 1.416 0.001 0.867 37.34 36.46 0.01 25 82 2.15 5.00 33 12.00 120 13 1.416 0.000 0.867 36.52 35.65 0.01 26 83 2.22 5.00 33 12.00 120 13 1.416 0.001 0.867 35.72 34.84 0.01 27 84 2.87 5.00 33 12.00 120 13 1.416 0.001 0.867 34.93 34.05 0.01 28 85 3.91 5.00 33 12.00 120 13 1.416 0.001 0.867 34.15 33.26 0.02 29 86 5.26 5.00 33 12.00 120 13 1.416 0.003 0.867 33.45 32.54 0.04 30 87 6.72 5.00 33 12.00 120 13 1.416 0.004 0.867 32.83 31.89 0.07 31 88 84.80 5.00 33 12.00 120 13 1.416 0.437 0.867 32.23 23.93 7.43 32 89 80.29 5.00 33 12.00 120 13 1.416 0.395 0.867 31.95 24.37 6.72 33 90 84.61 5.00 33 12.00 120 13 1.416 0.435 0.867 31.85 23.58 7.40 40 100 -27.63 3.00 33 12.00 120 13 1.416 0.055 -0.867 40.39 42.08 -0.82 41 101 -24.40 3.00 33 12.00 120 13 1.416 0.044 -0.867 40.35 41.87 -0.65 42 102 -21.39 3.00 33 12.00 120 13 1.416 0.034 -0.867 40.24 41.62 -0.51 43 103 -18.57 3.00 33 12.00 120 13 1.416 0.026 -0.867 40.06 41.32 -0.39 44 104 -15.80 3.00 33 12.00 120 13 1.416 0.019 -0.867 39.78 40.93 -0.29 45 105 -13.07 3.00 33 12.00 120 13 1.416 0.014 -0.867 39.38 40.45 -0.21 46 106 -10.62 3.00 33 12.00 120 13 1.416 0.009 -0.867 38.87 39.90 -0.17 47 107 -8.43 3.00 33 12.00 120 13 1.416 0.006 -0.867 38.30 39.29 -0.12 48 108 -6.52 3.00 33 12.00 120 13 1.416 0.004 -0.867 37.67 38.62 -0.09 49 109 -4.92 3.00 33 12.00 120 13 1.416 0.002 -0.867 36.98 37.91 -0.06 50 110 -3.63 3.00 33 12.00 120 13 1.416 0.001 -0.867 36.25 37.17 -0.04 51 111 -2.66 3.00 33 12.00 120 13 1.416 0.001 -0.867 35.49 36.39 -0.04 52 112 -2.15 3.00 33 12.00 120 13 1.416 0.000 -0.867 34.70 35.60 -0.03 53 113 -2.22 3.00 33 12.00 120 13 1.416 0.001 -0.867 33.90 34.80 -0.03 54 114 -2.87 3.00 33 12.00 120 13 1.416 0.001 -0.867 33.07 33.97 -0.04 55 115 -3.91 3.00 33 12.00 120 13 1.416 0.001 -0.867 32.21 33.12 -0.05 INDUSTRIAL FIRE SPRINKLER CO., INC. F'LOREXFO - Grid @ Angled Wall PAGE 4 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. 'T Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3=1 T'/ross, 4=Butterfly Valve, 5--Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. ERIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 56 116 -5.26 3.00 33 12.00 120 13 1.416 0.003 -0.867 31.38 32.29 -0.04 57 117 -6.72 3.00 33 12.00 120 13 1.416 0.004 -0.867 30.57 31.50 -0.06 58 118 57.91 3.00 33 12.00 120 13 1.416 0.216 -0.867 29.70 27.33 3.24 59 119 122.87 3.00 33 19.00 120 13 2.115 0.123 -0.867 29.49 27.65 2.71 70 100 27.63 92.00 0.00 120 13 1.416 0.055 0.000 47.13 42.08 5.04 71 101 24.40 92.00 0.00 120 13 1.416 0.044 0.000 45.88 41.87 4.00 72 102 21.39 92.00 0.00 120 13 1.416 0.034 0.000 44.76 41.62 3.14 73 103 18.57 92,00 0.00 120 13 1.416 0.026 0.000 43.74 41.32 2.42 74 10.4 15.80 92.00 0.00 120 13 1.416 0.019 0.000 42.72 40.93 1.79 75 105 13.07 92.00 0.00 120 13 1.416 0.014 0.000 41.71 40.45 1.26 76 106 10.62 92.00 0.00 120 13 1.416 0.009 0.000 40.76 39.90 0.86 77 107 8.43 92.00 0.00 120 13 1.416 0.006 0.000 39.85 39.29 0.56 78 108 6.52 92.00 0.00 120 13 1.416 0.004 0.000 38.97 38.62 0.35 79 109 4.92 92.00 0.00 120 13 1.416 0.002 0.000 38.12 37.91 0.21 80 110 3.63 92.00 0.00 120 13 1.416 0.001 0.000 37.28 37.17 0.12 81 111 2.66 92.00 0.00 120 13 1.416 0.001 0.000 36.46 36.39 0.07 82 112 2.15 92.00 0.00 120 13 1.416 0.000 0.000 35.65 35.60 0.04 83 113 2.22 92.00 0.00 120 13 1.416 0.001 0.000 34.84 34.80 0.05 84 114 2.87 92.00 0.00 120 13 1.416 0.001 0.000 34.05 33.97 0.08 85 115 3.91 92.00 0.00 120 13 1.416 0.001 0.000 33.26 33.12 0.14 86 146 5.26 33.00 0.00 120 13 1.416 0.003 0.000 32.54 32.46 0.08 146 147 5.26 8.00 0.00 120 13 1.416 0.003 0.000 32.46 32.44 0.02 147 148 5.26 8.00 0.00 120 13 1.416 0.003 0.000 32.44 32.42 0.02 148 149 5.26 8.00 0.00 120 13 1.416 0.003 0.000 32,42 32.37 0.05 149 116 5.26 33.00 0.00 120 13 1.416 0.003 0.000 32.37 32.29 0.08 87 130 6.72 17.00 0.00 120 13 1.416 0.004 0.000 31,89 31.82 0.07 88 187 84.80 9.00 0.00 120 13 1.416 0.437 0.000 23.93 20.00 3.93 187 131 59.75 8.00 0.00 120 13 1.416 0.229 0.000 20.00 18.14 1.86 130 132 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.82 31.79 0.03 131 133 35.90 8.00 0.00 120 13 1.416 0.089 0.000 18.14 17.41 0.74 132 134 6.72 8.00 0.00 120 13 1.416 0.004 0,000 31.79 31.76 0.03 133 135 12.53 8.00 0.00 120 13 1.416 0.013 0.000 17.41 17.30 0.10 134 136 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.76 31.73 0.03 135 137 -10.76 8.00 0.00 120 13 1.416 0.010 0.000 17.30 17.39 -0.09 136 138 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.73 31.70 0.03 137 139 -34.11 8.00 0.00 120 13 1.416 0.081 0.000 17.39 18.05 -0.66 138 140 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.70 31.64 0.06 139 141 -57.91 8.00 0.00 120 13 1.416 0.216 0.000 18.05 19.78 -1.73 140 142 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.64 31,60 0.03 141 143 -57.91 8.00 0.00 120 13 1.416 0.216 0.000 19,78 21.50 -1.73 142 144 6.72 8.00 0.00 120 13 1.416 0.004 0.000 31.60 31.57 0.03 143 145 -57.91 8.00 0.00 120 13 1.416 0.216 0.000 21.50 23.23 -1.73 144 117 6.72 19.00 0.00 120 13 1.416 0.004 0.000 31.57 31.50 0.08 INDUSTRIAL FIRE SPRINKLER CO., INC. FTOREXPD - Grid @ Angled Wall FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3=1 T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing check Valve FROM TO FLOW PIPE FITS EQV. H-N PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 145 118 -57.91 19.00 0.00 120 13 1.416 0.216 0.000 23.23 27.33 -4.10 89 170 80.29 9.00 0.00 120 13 1.416 0.395 0.000 24.37 20.81 3.56 170 171 54.74 8.00 0.00 120 13 1.416 0.194 0.000 20.81 19.22 1.59 171 172 30.19 8.00 0.00 120 13 1.416 0.065 0.000 19.22 18.69 0.53 172 173 5.97 8.00 0.00 120 13 1.416 0.003 0.000 18.69 18.67 0.02 173 174 -18.22 8.00 0.00 120 13 1.416 0.025 0.000 18.67 18.89 -0.22 174 175 -42.56 8.00 0.00 120 13 1.416 0.122 0.000 18.89 19.86 -0.98 175 176 -42.56 1.00 0.00 120 13 1.416 0.122 0.000 19.86 19.99 -0.13 176 177 -67.60 4.00 0.00 120 13 1.416 0.287 0.000 19.99 21.14 -1.15 90 178 84.61 9.00 -0 0.00 120 13 1.416 0.435 0.000 23.58 19.66 3.92 178 179 59.78 8.00 -0 0.00 120 13 1.416 0.229 0.000 19.66 17.81 1.85 179 180 36.15 7.00 -0 0.00 120 13 1.416 0.090 0.000 17.81 17.18 0.63 180 181 36.15 1.00 -0 0.00 120 13 1.416 0.090 0.000 17.18 17.1b 0.08 181 182 12.99 14.00 22 4.98 120 13 1.416 0.014 0.000 17.10 16.84 0.26 182 183 -9.41 8.00 -0 0.00 120 13 1.416 0.007 0.000 16.84 16.91 -0.0' 183 184 -31.85 8.00 -0 0.00 120 13 1.416 0.071 0.000 16.91 17.48 -0.57 184 177 -55.26 10.00 23 8.49 120 13 1.416 0.198 0.000 17.48 21,14 -3.66 177 119 -122.87 45.00 22 7.82 120 13 2.115 0.123 0.000 21.14 27.65 -6.50 182 185 22.40 1.50 3 4.99 120 13 1.087 0.135 0.000 16.84 16.00 0.84 183 186 22.44 1.50 3 4.99 120 13 1.087 0.135 0.000 16.91 16.05 0.86 A MAX. VELOCITY OF 17.27 ft. /sec. OCCURS BETWEEN REF. PT. 88 AND 187 Sprinkler-CLC Release 6.3 By Walsh Engineering Inc. North Kingstown R.I. U.S.A. I INDUSTRIAL FIRE SPRINKLER CO., INC. FLDREXPO - Grid @ Angled Wall PAGE 5 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 Indicates Equivalent Length. T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-N PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpni) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 145 118 -57.91 19.00 0.00 120 13 1.416 0.216 0.000 23.23 27.33 -4.10 89 170 80.29 9.00 0.00 120 13 1.416 0.395 0.000 24.37 20.81 3.56 170 171 54.74 8.00 0.00 120 13 1.416 0.194 0.000 20.81 19,22 1.59 171 172 30.19 8.00 0.00 120 13 1.416 0.065 0.000 19.22 18.69 0.53 172 173 5.97 8.00 0.00 120 13 1.416 0.003 0.000 18.69 18.67 0.02 173 174 -18.22 8.00 0.00 120 13 1.416 0.025 0.000 18.67 18.89 -0.22 174 175 -42.56 8.00 0.00 120 13 1.416 0.122 0.000 18.89 19.86 -0.98 175 176 -42.56 1.00 0.00 120 13 1.416 0.122 0.000 19.86 19.99 -0.13 176 17.7 -67.60 4.00 0.00 120 13 1.416 0.287 0.000 19.99 21.14 -1.15 90 178 84.61 9.00 -0 0.00 120 13 1.416 0.435 0.000 23.58 19.66 3.92 178 179 59.78 8.00 -0 0.00 120 13 1.416 0.229 0.000 19.66 17,81 1.85 179 180 36,15 7.00 -0 0.00 120 13 1.416 0.090 0.000 17.81 17.18 0,63 180 181 36.15 1.00 -0 0.00 120 13 1.416 0.090 0.000 17.18 17.10 0.08 181 182 12.99 14.00 22 4.98 120 13 1.416 0.014 0.000 17.10 16.84 0.26 182 183 -9.41 8.00 -0 0.00 120 13 1.416 0.007 0.000 16.84 16.91 -0,07 183 184 -31.85 8.00 -0 0.00 120 13 1.416 0.071 0.000 16.91 17.48 -0.57 184 177 -55.26 10.00 23 8.49 120 13 1.416 0.198 0.000 17.48 21.14 -3.66 177 119 -122.87 45.00 22 7.82 120 13 2.115 0.123 0.000 21.14 27.65 -6.50 182 185 22.40 1.50 3 4.99 120 13 1.087 0.135 0.000 16.84 16.00 0.84 183 186 22.44 1.50 3 4.99 120 13 1.087 0.135 0.000 16.91 16.05 0.86 A MAX. VELOCITY OF 17.27 ft . /sec. OCCURS BETWEEN REF. PT. 88 AND 187 Sprinkler-CLC Release 6.3 By Walsh Engineering Inc. North KingstownR.I. U.S.A. As0000gl A DRY SPRINKLERS PENDENT, DEEP CEILING PENDENT, RECESSED PENDENT, AND UPRIGHT MODEL F960 DESIGNER, SR, 5 mm BULB TYPE, 1/2(15m)-QFICE The .1/2 inch (15 mm) orifice Model F960 Designer Pendent, Deep Ceiling Pendent, Recessed Pendent, and Up- right Dry Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are standard re- sponse - standard orifice spray sprink- lers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recog- nized by the applicable Listing or Ap- proval agency (e.g., UL Listing is based on NFPA 13 requirements). The Pendent, Deep Ceiling Pendent, Re- cessed Pendent, and Upright Sprink- lers all produce a hemispherical water discharge pattern below the deflector. Available in a wide range of operating temperatures and order lengths, the the F960 is intended for use in the following types of applications: Where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures e.g. sprinkler drops from unheated portions of buildings) Where sprinklers and/or a portion of the connecting piping may be ex- posed to freezing temperatures (e.g. sprinkler drops from wet systems into freezers or sprinkler sprigs from vet systems into unheated attics) Where pendent sprinklers are used on systems that are seasonably drained to avoid freezing (e.g. vaca- tion resort areas) When the F960 is in service, water is prevented from entering the assembly by the Plug & 0-ring (Ref. Figure C) in the Inlet of the Sprinkler. Upon expo- sure to a temperature sufficient to op- erate the Bulb, the Bulb shatters and the Bulb Seat is released. The com- pressed Spring is then able to expand an: :ush the WaterTube as well as the Tuc ouiwarc. This ac10n Si- _:aneousiv :u:s ;r,'a-: on the witnorawina tne iuc & 0-ring me inie,, an: Inmatinc water flow. The Standard, Deep Ceiling, and Re- cessed Escutcheons for the F960 Dry Pendent Sprinklers are separable two- SPRINKLER r (REFER TO SYSTEM DES G.. SECTION)7 C N FACE FITTING\ OF ORDER LENGTH CE WRENCH, C EiING EFER TO SYSE'. :55 s _\ 1 - - _ FAcE OF FITTING ORE LENGT-. FILL- CEI Older length 'R of 3-1/2 to 48 inSies (88.9 to 1219.2 mm - 1/4 inch (5.4 mr' rcements. RECESSED PENDENT (With Recessed Escutcheon) SPRINKLER ITTING (REFER TO SYSTEM DESIGN SECTION)7 I '•).___j FACEOF I NPT FITTING LD,\ LJ ORDER LENGTH FACE OF WREN CEILING FLAT Order Length "0" è1f.1/2 to 46 inches (12,7 to 1168,4 mm) in. 1/2 inch (12,7 mm) increments. DEEP CEILING PENDENT (With Deep Ceiling Escutcheon) TOP OF \ DEFLECTOR ORDER LENGT FITTING H \ Z 7 FACE OF H \ I, :5 SPRINKLER ITTING (REFER TO SYSTEM DESIGN SECTION) Order Length "U' of 5 to 48 inches (127,0 to 1219.6 mm) in 1/2 inch (12.7 mm) increments. UPRIGHT (Without Escutcheon) Order Length S of 2-1/2 to 48 inch' - (63,5 to 1219,2 mm) in 1/2 inch (12,7 mm) increments. PENDENT (With Standard Escutcheon) Pipe thread connechcns per ISO 7/1 can be provided on special request. -FIGURE A MODEL F960 DRY SPRINKLERS Printec in U.S.A. 12-96 T0552 DISCHARGE 14 U.S GALLONS PER MINUTE (CPU) DISC'.ARGE IN LITERS PER MINUTE SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL I CHROME RATING LIQUID COLOR BRASS I PLATED I 135F/57'C Orange PENDENT 155F/68C Red DEEP CEILIN,9 PENDEN 175F/79'C and 1,2,3,5 Yellow > 200F/93C Green UPRIGHT 286'F/141*C Blue 360F/182C Mauve 135'F/57C Orange RECESSED PENDENT** 155F/68C Red 12,4,5 175'F,79'C Yellow 200F/93C Green NOTES: Listed by Underwriters Laboratories, Inc. Listed by Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corporation. Approved by Factory Mutual Research Corporation for use in Light Hazard and Ordinary Hazard (Groups 1 and 2) Occupancies. The FM Approvals for Ordinary Hazard Occupancies is limited to wet pipe sprinkler systems and preaction systems qualifying as ''el pipe systems. Accepted by the City of New York under MEA 39-92-M. Order lengths of 2-1/2 to 48 inches (63,5 to 1219,2 mm) in 1/2 inch increments. Order lengths of 1/2 to 46 inches (12,7 to 1168,4 mm) in 1/2 inch increments. Order lengths of 5 to 48 inches (127,0 to 1219,2 mm) in 1/2 inch increments. Order lengths of 3-1/2 to 48 inches (88,9 to 1219,2 mm) in 1/4 inch increments. TABLE A LABORATORY LISTINGS AND APPROVALS FIGURE B NOMINAL DISCHARGE CURVE PLUG B 0-RING -INLET YOKE CASING SPRING piece desians which allow installation of the sprinklers and pressure testing of the fire protection system. prior to installation of a suspended ceiling. They also permit removal of sus- pended ceiling panels without having to first shut down the fire protection system and remove the sprinklers. The combination of the outside diameter for the outer piece and the diameter of the ceiling hole also contributes to the ease of installation by covering offset clearance holes. Laboratory listings and approvals for the 1/2 inch (15 mm) orifice Model F960 -Dry Sprinklers are given in Table A. WARNING The Model F960 Dry Sprinklers de- scribed herein must be installed and maintained in compliance with this documerz. as well as applicable stan- ccrs of he Varionc Fire Protection 0n to the stan acrds or cn.y outer cuthorities having tsdcr:on. Faure to do so may tin- pair the integrity of these devices. The owner is responsible for main- taining their fire protection system and detices in proper operating con- dition. The installing contractor or manufacturer should be contacted rel- atiue to any questions. The Model F960 Dry Sprinkler must on/v be installed in fittings that meet the requirements of the System Design section. The 1/2 inch (15 mm) orifice Model F960 Dry Sprinklers are rated for use at a maximum service pressure of 175 psi (12,1 bar). The available tempera- ture ratings, order lengths, sprinkler finishes, and escutcheon finishes, as applicable, are given in Tables B, C, D, and E. The nominal discharge curve plotted in Figure B represents the flow "Cl" in GPM (LPM) as determined by the fol- lowing formula: 0 = Ko wnere tne nominal discharge coeffi- cient "K" equals 55 (79,2); and, 'p' equals the residual pressure in psi (bar). Listing standards permit the ac- tual value of "K" to vary from 5.3 to 5.8 (76,4 to 83,6); however, for hydraulic INSERT TU BULB SEAT VENT HC.S-- -t11 BULB FRAME . FLECTOR FIGURE C MODEL F960 DRY SPRINKLER —ASSEMBLY— (Pendent Deflector Shown) calculations a K-factor of 5.5 (79,2) is to be apec. Figure C .iIus:aes the F960 assem- bly. The u: an: niet are brass per ASTMBi C2:c:.andtheO-rings silicone rLTte. Tne Casing is galva- nized caon steel per SAE 1008 Class M. The rame is bronze per ASTM B62 (C53600), the Deflector is D.7/Q" flit, 3' D'A 76,2 mm) 1-3/4" DIA, 44,5 mm) 1-3/81 /8' (34,91 3,2 mm 2-3/16" ± 1/4 (55,6 6,4mm) -l/2' lilt, PENDENT DEEP CEILING PENNT RECESSED PENDENT (With Two-piece 7wQpieiee (With Two-piece Standard Escutcheon) DeepCT1ffig Escutcheon) Recessed Escutcheon) FIGURE D PENDENT, DEEP CEILING PENDENT, AND RECESSED PENDENT CEILING DETAILS p brass per ASTM B36 (022000), the Compression Screw is bronze per ASTM B140 (C31400).The Water Tube is brass per ASTM B135 (033000). The Bulb Seat, Spring, and Yoke are all Type 302 stainless steel. The Guide Tube sub-assembly is con- structed of Type 302 stainless steel and brass per ASTM B16 (031600). The two pieces of the Standard, Deep Ceiling, and Recessed Escutcheons are low carbon steel. The inner piece of each type escutcheon is perma- nently secured to the F960 assembly. SYSTEM DESIGN The F960 Dry Sprinklers are to be in- stalled in the 1 inch NPT outlet of a malleable iron threaded tee fitting per ANSI B16.3 or cast iron threaded tee fitting per ANSI 816.4 with the end sprinkler fitting on a branch line to be plugged as shown in Figure A: or, in- stalled in the side outlet of a Gruvlok® Figure 7105 Sock-ItTM x 1 inch NPT side outlet fitting manufactured by Grinnell, Corporation. Only use maxi- mum 2-1/2 inch size reducing tee's for dry pipe sprinkler systems. NOTES Do not install the F960 into any other type fitting without first consulting the Technical Data Department. Fail- ure to use the cDropr1ate ñtting ma\ resu.t zr: 0" :i .jrinkler to proeri' ooerare dui' to r'ormarion of ice over the nie: P'ug or binding of the inlet Plug; or, insufficient engagement of the inlet pipe threads with conse- quent leakage. - In the case of a dry pipe sprinkler system subject to freezing, the use of a fitting of other than the types specified may result in failure of the sprinkler to properly operate due to the forma- tion of ice over the F960 Inlet. Branch, cross, and feedmain piping connected to F960 Dry Sprinklers and subject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When F960 Dry Sprinklers are to be used in wet pipe sprinkler systems pro- tecting areas subject to freezing tem- peratures (e.g., sprinkler drops into freezers or sprinkler sprigs into attics), consideration must be given to the ap- propriate length of the sprinkler that will prevent freezing of the water in the connecting pipes, due to conduction. When the temperature surrounding the wet pipe sprinkler system is main- tained at a minimum temperature of 40'F/40, the following are the mini- mum recommended lengths between the face of the F960 sprinkler fitting and the outside surface of the pro- tected area (i.e., length exposed to minimum ambient of 40F/4'C): 12 inches (300 mm) when the tem- perature within the protected area is -20' Fl-29 'C 18 inches (450 mm) when the tern- Derature within tne Drotected area is -40F/-400: and. 24 inches (600 mm) when the tem- perature within the protected area is -60'F/-51'C. NOTE When the F960 Pendent, Deep Ceiling Pendent, or Recessed Pendent Sprink- lers penetrate a ceiling into an area subject to freezing, the clearance space around the Sprinkler Casing must be completely sealed, in order to prevent the leakage of moist air into the freez- ing area which might result in the formation of condensate around the Frame, Deflector, Bulb Seat, or Bulb. Failure to prevent the formation of condensate could result in the build- up of ice around the releasing compo- nents and, consequently, either an in- adL'ertant operation of the sprinkler or, impaired operation due to reduced thermal sensitivity. -3- t DuPont Registered Trademark TA\ INDIC-TING BOSSES RE I.\ LINE WITH SPRiN.ER FRAME ARMS FIGURE E MODEL P870 WRENCH NOTES The Model F960 Dry Sprinkler must only be installed in fittings that meet the requirements of the System Design section. Refer to the System Design section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Ccs:r.g. Do rot install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The diame- ter of the a:r bubble varies from ap- proximately 1/16 inch (1,6 mm) for the 135'F/57'C rating to 1/8 inch (3.2 mm) for the 360'F/ 182'C rating. Prior to installing either Pendent, Deep Ceiling Pendent, or Recessed Pen- dent Sprinklers, verify that the sprink- ler fitting is located so that the face-of- fitting to face-of-ceiling distance is within plus or minus 1/4 inch (6,4 mm) of the sprinkler order length for Stan- dard or Deep Ceiling Escutcheon in- stallations or within plus or minus 1/8 inch (3,2 mm) for Recessed Escutch- eon installations. The remaining es- cutcheon adjustment can then be used to compensate for the possible manu- facturing variations in the take-out of the fittings. as well as in the make-in of the sDrinklers as oerrnitted by ANSI Proceed with the installation as fol- lows: 1. Apply pipe thread sealant sparingly to the 1 inch NPT sprinkler threads PSN 60 - XXX.- X - XXX ORDEP I LENGTH I 2.5 to 4E : In 1/2 In: I MPERANF r I Incremer RATING PRINKLER ESCUTCHEON (EXAMPLE- E 960 960 135F/57C PLATE I FINISH 961 155F/68'C 055 5.5 0 CHROME 962 175F/79'C PLATED 080 8.0' 963 200F/93'C 1 NATURAL WHITE 185 18.5' BRASS PAINTED 964 286F/ 141 'C 36.5' 9 CHROME CHROME 965 360'F/182C PLATED PLATED 370 TABLE B PSN SELECTION - MODEL F960 DRY PENDENT SPRINKLERS 't53 I OR PSN 60 - XXX.- X - XXX LE NG'I 0.5" to 4E I TEMPERATURE In 1/2 In: RATING Incremer:s (EXAMP..EPLATE 930 135'F/5FC R 7FN ESCUTCHEO FINISH 0.5' 931 155'F/68'C 005 0 CHROME WHITE 8.0 932 175'F/79'C PLATED PAINTED 080 933 200'F/93'C 1 NATURAL WHITE 185 BRASS PAINTED 36.' 934 286'F/141C 1 365 CHROME M CHROME 37C' 935 360'F1182'C PLATED PLATED 370 TABLE C PSN SELECTION - MODEL F960 DEEP CEILING DRY PENDENT SPRINKLERS levels of torque may distort Inlet with consequent leakag impairment of the sprinkler Do not attempt to make-up for sufficient adjustment in the es- cutcheon by under- or over-tit- ening the sprinkler. Readjust e position of the sprinkler fittir. o suit. When using the F870 Wre-.: push up on the Wrench while being turned to ensure thc: Wrench recess stays fully with the sprinkler wrench fic:. 3. After a suspended ceiling has :en installed or the finish coat has ceen applied to a fixed ceiling (as app:ca- bie), slide on the outer piece c .e only. Use of a Tefiont based pipe joint sealant is recommended. 2. Install the F960 by wrenching on the Casing with a pipe wrench, when- ever the Casing is readily access- able. Otherwise, use a 10 inch adjustable wrench applied to the sprinkler wrench flats for Standard and Deep Ceiling Escutcheon installations or, the Model F870 Sorinkler Wrench (Ref. Fiaure El with a 1/2 inch s:sec Escutch- eon instaiiauons. NOTES A leak tight 1 inch NPT sprinkler joint should be obtained with a torque of 20 to 30 ft.lbs. Higher -4- 0 PSN 60 - XXX.- X- XXX ORDER LENGTH 3.5" to 48.0" In 1/4 Inch Increments SPRINKLER ESCUTCHEON (EXAMPLE) INISH PLATE TEMPERATURE FINISH RATING 055 5.50" - - 0 CHROMEN WHITE - 970 135F /57"C PLATED -..INTED 082 8.25" 971 155'F 68'C 1 NATURAL W TE 180 18.00" BRASS PAIN 972 175"F /79"C - ___________ 187 1875 9 CHROME CHROME 973 200"F / 93"C PLATED PLATED 372 37.25" TABLE D PSN SELECTION - MODEL F960 DRY RECESSED PENDENT XXX. X - XXX ORDER PS\NN 6 I LENGTH I 5.0". to 48.0" TEMPERATURE F1 In 1/2 Inch Increments RATING 980 135"F/57C (EXAMPLE) 981 155"F168"C SPR1N.LER 055 5.5" 8.0" FINISP..\ 982 175"F179"C 080 983 200F I 93C 1 NATURAL 185 18.5" - BRASS 36.5" - 984 286F1 141"C 365 - CHROME 37.0" 985 360"FI 182C PLATED S" TABLE PSN SELECTION - MODEL F960 DRY UPRIGHT SPRINKLES 0 Escutcheon until it comes in contact with the ceiling. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Ceiling Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Automatic sprinklers must never be shipped or stored where their temper- attires will exceed 100F/38"C and they mist never be painted, plated, coated or otherwise altered after leav- ing the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated. should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - both before and after installation. Sprinklers dam- aged by dropping. striking, wrench twist/slippage, or the like, must be re- placed. Also. repiace ani sprinkler ma: has a cracked bulb or that has los: liquid from its bulb. (ret. Installation Section Note.) NOTES Absence of the outer piece of an es- -5- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in afire situation. Before closing a fire protection system control value for maintenance work on the fire protection system which it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quar- terly by a qualified Inspection Service. NOTES It is recommended that the piping connected to pendent and recessed pendent sprinklers be periodically checked to assure that proper pitch and drainage is in accordance with the minimum requirements of the Na- tional Fire Protection Association, if the piping is subject to freezing tem- peratures. .4. 'Hnt Hole is provided i n the iieih Seat (Ref Figure C) to indicate if the Dry Sprinkler is remaining diy. Evi- dence of leakage from the Vent Hole is an indication that the Plug and 0. ring may be leaking and, therefore, is an indication that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improper in- stallation or an ice plug). The fire protection system control valve must be closed and the system drained b. fore removing the sprinkler. Seller warrants for a period of one year from the date of shipment (warranty period) that the products furnished hereunder will be free from defects in material and workmanship. For further details on Warranty. see Price List. ORDERI NG PROCEDURE 1 Model F960 Dry Sprinklers are fur- nished based upon "Ordered Lengths' (refer to Figure A). After the measured length is taken, round the measure- ment up or down to the nearest incre- ment available (i.e., 1/2" for Pendent, Deep Ceiling Pendent, and Upright; or, 1/4" for Recessed Pendent). Orders must include the description and Prod- uct Symbol Numbers. Unless otherwise specified, F960 Sprinklers are provided with NPT pipe thread connections. Pipe thread con- nections per ISO 7/1 can be provided on special request. Dry Pendent Sprinklers with Standard Escutcheon: Specify: (temperature rating) Model F960 Dry Pendent Sprinkler with Stan- dard Escutcheon, (specify type) finish Sprinkler, (specify type) finish Es- cutcheon Plate, and "S" Order Length of (specify) inches, PSN (specify from Table B). Replacement Parts: Specify: F960 Standard Outer Es- cutcheon with (specify finish), PSN (specify). Painted White .............PSN 56.960-0-007 Chrome Plated ............PSN 56-960-9-007 Specify: Deep Ceiling Escutcheon for F960 Dry Sprinkler with (specify fin- ish), PSN (specify). Painted White .............PSN 56-4320-004 Chrome Plated ............PSN 56-432-9-004 Specify: F960 Recessed Outer Es- cutcheon with (specify finish), PSN (specify). Painted White .............PSN 56-701-4-010 Chrome Plated ............PSN 56-701-9-010 U.S.A. Patent No. 5,188185 applies to the Model F960 Dry Sprinkler. Dry Pendent Sprinklers with Deep Ceiling Escutcheon: Specify: (temperature rating) Model F960 Dry Pendent Sprinkler with Deep Ceiling Escutcheon, (specify type) fin- ish Sprinkler, (specify type) finish Es- cutcheon Plate, and "0" Order Length of (specify) inches, PSN (specify from Table C). Dry Pendent Sprinklers with Recessed Escutcheon: Specify: (temperature rating) Model F960 Dry Pendent Sprinkler with Re- cessed Escutcheon. (specify type) fin- ish Sprinkler. (specify type) finish Es- cutcheon Plate, and "R' Order Length of (specify) inches, PSN (specify from Table 0). Dry Upright Sprinklers: Specify: (temperature rating) Model F960 Dry Upright Sprinkler (specify type) Sprinkler with "U" Order Length of (specify) inches. PSN (specify from Table E). Sprinkler Wrench: Specify: Model F870 Sprinkler Wrench, PSN 56-870-1-001. Contact your local distributor for avail- ability. 0 Rag. trademark of GRINNELL CORPORATION, 3 TYCO PARK, EXETER, NH 03833 A t1jc17 INTERNATIONAL LTD. COMPANY