Loading...
HomeMy WebLinkAbout1969 KELLOGG AVE; ; FPC2018-0382; PermitPERMIT REPORT (qity of Cdlsbad Fire Sprinklers Print Date: 11/03/2021 Job Address: 1969 KELLOGG AVE. CARLSBAD, CA 92008-6582 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2120921200 Track #: Valuation: $275,000.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0382 Status: Closed - Finaled Applied: 11/21/2018 Issued: 12/18/2018 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: Project Title: Description: KELLOGG FLOWER MARKET COOLER PROJECT -SPRINKLER TI (77 HEADS) Applicant: FPContractor: WEST COAST FIRE PREVENTION INC WEST COAST FIRE PROTECTION DAN AMATO 271 ROYMAR RD, # SUITE F 5416 LOGANBERRY WAY OCEANSIDE, CA 92058-1301 OCEANSIDE, CA 92057-4640 (760) 754-8472 (760) 754-8472 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tqL:L70 Worldwide Contacts I www.tyco-fire.com Model DSB-2 Dry Sprinkler Boot For Use With TFP Dry Type Sprinklers General Description The TYCO Model DSB-2 Dry Sprinkler Boot (Ref. Figure 1) is designed for use with TFP Dry Type Sprinklers. When properly installed, it will help close the air gap created by the clearance hole through a wall or ceiling through which the dry type sprinkler has penetrated. The DSB-2 is intended predominately for use with clearance holes through freezer ceiling structures. In these types of installations, due to the greater temperature difference between the inside and outside of the freezer than found with other type installations, the potential for the formation of conden- sation in the sprinkler and subsequent ice build-up is increased. If this con- densation is not controlled, ice build-up can occur that might damage the dry type sprinkler and/or prevent proper operation in a fire situation. The DSB-2 is intended to help stop the air exchange between the inside and outside of the freezer (or any other type of similar construction) to help prevent transfer of moist air into the freezer space. The use of the DSB-2 provides a quick and efficient means of closing the air gap created by the dry type sprinkler clearance hole. The DSB-2 provides the added feature of eliminat- ing the occurrence of cracking of some commonly used sealants, that subse- quently allows the passage of moist air. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 L(s1ItII The Model DSB-2 Dry Sprinkler Boot described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Approvals The TYCO Model DSB-2 Dry Sprin- kler Boot does not require laboratory approval to be installed in accordance with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION. The use of the DSB-2 does not alter any of the applicable labo- ratory approvals for TFP Dry Type Sprinklers. The 2007 edition of NFPA 13, Section 8.4.10.2 requires that dry sprinklers connected to wet pipe sprinkler systems protecting insulated freezer structures, the clearance space around the sprinkler barrel shall be sealed. Dry Type Sprinkler Compatibility and Technical Data Sheet Reference Series DS-1, Standard Response Standard Coverage, Pendent, Upright and HSW ....................TFP500 Series DS-1, Quick Response Standard Coverage, Pendent, Upright and HSW ....................TFP51O Series DS-C, Standard Coverage Concealed Pendent ............TFP515 Series DS-ECC, Extended Coverage Concealed Pendent ............TFP518 AUGUST 2018 Series DS-1, Extended Coverage Horizontal Sidewall ............TFP52O Series DS-2, Standard Coverage Pendent ............. TFP53O Series DS-2, Extended Coverage Pendent .............TFP54O Series DS-3, ECOH Horizontal Sidewall ............TFP55O NOTE: Use of the Model DSB-2 Dry Sprinkler Boot with non-TFP Dry Type Sprinklers will void the warranty. Failure may result due to dimensional differ- ences in the outside diameter of the barrel. The DSB-2 has not been tested with any non-TFP Dry Type Sprinklers with regard to fit or performance. Physical Characteristics The Boot is EPDM, the Strap Ties are nylon, and the Adhesive is ethyl cyano- acrylate based. The adhesive is formu- lated for instant bonding of the Boot to metal, plastic, or rubber surfaces. Design Criteria There are four items to be considered: Dry Type Sprinklers, Clearance Hole, Exposure Length, and Sprinkler Fitting. Dry Type Sprinklers This Technical Data section provides a list of all of the compatible dry type sprinklers and their associated techni- cal data sheets. Refer to the applicable technical data sheet for installation and maintenance information for the sprin- kler being utilized. TFP591 'ADHESIVE' 3-3/4' DIA. STRAP TIES (953 mm) REF. (ENDS ON OPPOSING SIDES OF BOOT) 2 (50,8 mm) REF. 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE V TFP .- DRY TYPE SPRINKLER FIGURE 1 TYPICAL INSTALLATION OF MODEL DSB-2 DRY SPRINKLER BOOT WITH SERIES DS-1 DRY PENDENT SPRINKLER TFP59I Page 2 of 4 NOTICE The TFP Dry Type Sprinklers must be installed and maintained in compli- ance with the applicable technical data sheet. Failure to do so may impair the performance of these devices. Clearance Hole The Model DSB-2 Dry Sprinkler Boot may be used with a maximum 2-1/2 in. (63,5 mm) diameter clearance hole (i.e., the diameter of the hole in the ceiling or wall being penetrated by the dry type sprinkler, Ref. Figures 1 or 2). Based on the diameter of the Dry Type Sprinkler Barrel, the designated maximum clearance hole will com- pensate for non-centering of the Dry Type Sprinkler Barrel within the clear- ance hole. Where centering can be maintained, a clearance hole as large as 3 in. (76,2 mm) in diameter can be accommodated. NOTE: The clearance hole adjacent to the DSB-2 cannot be larger than 2-1/2 in. (63,5 mm) diameter for a non-concentric installation or 3 in. (76,2 mm) diameter for a concentric installation. Otherwise, the DSB-2 cannot perform as intended by closing the air gap. NOTE: Clearance holes greater than specified cannot be filled in with foam insulation, etc. In order for the DSB-2 to be effective in closing the air gap it must seat and seal against the smooth material of the ceiling or wall. Exposure Length When Dry Sprinklers are to be used in wet pipe sprinkler systems protecting areas subject to freezing temperatures (e.g., sprinkler drops into freezers), con- sideration must be given to the appro- priate length of the sprinkler that will prevent freezing of the water in the con- necting pipes due to conduction. When the temperature surrounding the wet pipe sprinkler system is maintained at a minimum temperature of 40°F (4°C), the following are the minimum recom- mended lengths between the face of the sprinkler fitting and the outside sur- face of the protected area (i.e., length exposed to minimum ambient tempera- ture of 40°F (4°C) - Ref. Figure 3): 12 inches (300 mm) when the tem- perature within the protected area is -20°F (-29°C) 18 inches (450 mm) when the tem- perature within the protected area is -40°F (-40°C) 24 inches (600 mm) when the tem- perature within the protected area is -60°F (-51°C) For protected area temperatures between those given above, the minimum recommended length from TFP59I Page 3 of 4 SPRINKLER FITTING Ir ' EXPOSURE LENGTH '°B - 2 (SEE DESIGN CRITERIA SECTION) I1 hi1 1iI TFP DRY TYPE SPRINKLER FIGURE 3 EXPOSURE LENGTH TO WET SYSTEM SPRINKLER FITTING (SEE DESIGN SIDE CRITERIA OUTLET SECTION) PLUGGED DSB-2 S]L)~J FIGURE 4 SPRINKLER FITTING IN HEATED AREA DRY RUN SYSTEM OUTLET PLUGGED SPRINKLER FITTING (SEE DESIGN CRITERIA SECTION) DSB-2 FIGURE 5 SPRINKLER FITTING IN UNHEATED AREA the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. NOTE: The temperature within the protected area must be based on the lowest expected temperature. For example: a freezer may be rated at -20°F (-290C), yet the condenser is emitting -30°F (-350C). The dry sprin- kler length must be calculated based on the lower temperature of -30°F (-35°C). Sprinkler Fitting TEP Dry Type Sprinklers must be installed in the 1 in. NPT outlet or run of a malleable or cast iron threaded tee as described in the applicable technical data sheets. With reference to Figure 4 and in conjunction with use in a wet pipe system, the sprinkler drop may be installed as shown. The information in Figure 4 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freezing. In areas subject to freez- ing, the pipe connected to the dry type sprinkler must be configured to allow complete drainage as shown in Figure 5. Installation The TYCO Model DSB-2 must be installed in accordance with this section. !FAY:IL'IIA'(cI The Adhesive contains cyanoacrylate ester. Irritation will occur when inhaled. This adhesive bonds skin in seconds. Contact through clothing may cause bums. EYE IRRITANT Always refer to the Material Safety Data Sheet for additional adhesive handling recommendations. The Material Safety Data Sheet should be obtained from the adhesive manufacturer via their web site noted on the adhesive con- tainer label before using the adhesive. In case of skin contact, flush with water, and for eye contact seek medical attention. Provide adequate ventilation in area of usage. When possible ventilation should be achieved by the use of local exhaust ventilation and good general ventilation. Vapors are heavier than air, therefore, downward ventilation should be used. When handling cyanoacrylate adhesives, goggles or safety glasses should always be worn. Polyethylene gloves should be used to protect the hands. TFP59I Page 4 of 4 'IY:lJII'(CI DO NOT USE RUBBER OR CLOTH GLOVES. RUBBER GLOVES WILL BOND WHEN BROUGHT IN CONTACT WITH THE ADHESIVE AND POROUS COTTON GLOVES WILL ABSORB THE ADHESIVE AND BOND THE GLOVES TO THE SKIN. Step 1. Prepare the clearance hole per the applicable TFP Dry Sprinkler Tech- nical Data Sheet. Step 2. Insert the dry sprinkler through the clearance hole and slide the Boot over threaded inlet of the dry sprinkler. NOTE: When installing on Series DS-2 Dry Sprinklers, the Boot will require stretching. The use of a grooved cou- pling gasket lubricant will ease installa- tion. Use only a petroleum free silicone grooved coupling gasket lubricant to avoid freezing of the Dry Sprinkler Boot to the Dry Sprinkler. NOTE: When sliding the Boot over the length of the Dry Sprinkler, sliding is easily accomplished by slightly squeez- ing the Boot around the cone area. Step 3. Thread the dry sprinkler into the sprinkler fitting per the applicable TFP Dry Sprinkler technical data sheet. NOTE: Refer to the sprinkler technical data sheet for tightening torque spec- ifications. The use of higher levels of torque then specified may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Step 4. Clean the contact surfaces of the Boot and the building (ceiling or wall) structure with a damp cloth. Moist surfaces will aid in a quick adhesion. NOTE: Use only a cloth that has been dampened with water. The use of other cleaning techniques, solvents, etc. may render the adhesive incapable of sealing. Step 5. Apply the provided Adhesive to the building structure in a zig-zag pattern. Refer to Warning regarding the adhesive. Step 6. Slide the Boot so that it comes in contact with the building structure, and then press the Boot firmly against the building structure to help ensure that the Adhesive is fully applied to both surfaces. NOTE: When sliding the Boot over the length of the Dry Sprinkler, sliding is easily accomplished by slightly squeez- ing the Boot around the cone area. Step 7. Wait two minutes to allow the Adhesive to sufficiently cure and then apply the two Strap Ties. The Strap Ties are to be applied to the straight section of the Boot as shown in Figure 1 and so that the ends are on opposing sides of the Boot. NOTE: The ties are to be pulled suf- ficiently tight to the point that there is no gap between Dry Sprinkler Boot and the Dry Sprinkler. When properly installed a paper clip or wire of similar dimension cannot be slipped between the Dry Sprinkler Boot and the Dry Sprinkler. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002 * Includes one Boot, two Strap Ties, and 1/3 oz of Adhesive (quantity of adhesive is sufficient for installing one Boot). 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NFPA ororogoierodcwle,eofuof Natoosi Fire Pratoccon itasoatafun Johnson •Z'0 Controls FPC20I8-0382 1969 KELLOGG AVE KELLOGG FLOWER MARKET COOLER PROJECT - SPRINKLER TI (77 HEADS) 2120921200 11/21/2018 FPC20I 8-0382 Worldwide I tqca Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 56K Pendent, Upright1 and Horizontal Sidewall Quick Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are decora- tive glass bulb automatic sprinklers designed for commercial use. Dry-type sprinklers are typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprinkler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors sprinklers are used on systems that are seasonally drained to avoid freezing (e.g., vacation areas) NOTICE The Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any authorities IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contact the installing contrac- tor or product manufacturer with any questions. The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Numbers (SINs) 3/4 in. NPT: 1Y3935 -Pendent TY3735 - Horizontal Sidewall 1 in. NPT: 1Y3235 —Pendent TY3135 - Upright TY3335 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved under MEA 352-01-E Previous New York City Approval and MEA certification numbers apply to product as shown in this data sheet. In accordance with Section BC 3502 of the Construction Code, current NYC Approvals for use in the City of New York apply to all products that contain UL or FM Approvals and Listings; therefore, not all products currently Approved for use in the City of New York will carry an actual MEA Certifi- cation number. Refer to Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 3/4 in. NPT 1 in. NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psil/2 (80,6 Ipm/barl/2) AUGUST 2018 EI! Temperature Ratings Refer to Tables A and B Finishes Sprinkler: Natural Brass, Chrome Plated, or Signal White Escutcheon: Signal White, Chrome Plated, or Brass Plated Physical Characteristics Inlet .............................Copper Plug............................Copper Yoke.......................Stainless Steel Casing .............Galvanized Carbon Steel Insert ...........................Bronze Bulb Seat...................Stainless Steel Bulb...............................Glass Compression Screw .................Bronze Deflector .........................Bronze Frame ............................Bronze Guide Tube .................Stainless Steel Water Tube .................Stainless Steel Spring .....................Stainless Steel Plug Spring*Stainless Steel Sealing Assembly. Beryllium Nickel w/TEFLON Escutcheon ...................Carbon Steel For 3/4 inch NPT only TFP5IO TFP5IO Page 2 of 10 PLUG WITH INLET SEALING ASSEMBLY ME INLET YOKE PLUG SPRING BAND II SPRING WATER TUBE CASING GUIDE INSERT TUBE BULB / SEAT FRAME 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1, 3/4 INCH NPT, DRY-TYPE SPRINKLER ASSEMBLY PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER II TUBE - CASING GUIDE - INSERT TUBE BULB FRAME / SEAT 3 mm BULB VENT HOLE _____ COMPRESSION DEFLECTOR SCREW FIGURE 2 SERIES DS-1, 1 INCH NPT AND ISO 7-R 1 DRY-TYPE SPRINKLER ASSEMBLY Operation When the TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hor- izontal Sidewall, Quick Response (3 mm bulb) and Standard Cover- age are intended for use in fire sprin- kler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1 inch NPT Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 inch NPT outlet or run of the follow- ing fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP5IO Page 3 of 10 3/4 Inch NPT TY3935 Pendent TY3935 Pendent TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon (Figure 5) with Standard Escutcheon (Figure 8) without Escutcheon (Figure 6) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C) Orange 1,2 1,2 Blue 1*,2* 155°F (68°C) Red (79°C) Yellow f (93°C)Green (141°C) Notes: I. Listed by underwriters Laboratories, Inc. (maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches) * Light and Ordinary Hazard occupancies only TABLE A 3/4 INCH NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 Inch NPT (and ISO 7-R 1) TY3235 Pendent 1Y3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figures) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upri9ht without Escutcrteont without Escutcheon (Figure 10) (Figure 7) Finish Bulb Natural ___________________________ Chrome White Natural Chrome White Natural Chrome White Color Code 6Temperature Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester Orange 2 3 4 ' ' ' Green 1 2 4 ' ' 1, 2, 3, 4 1, 2, 4 1,2,4 1',2-,3-14 1*1 2*1 4 Red 1 Yellow 200°F (93°C) 286°F (141°C) Blue Notes: Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches) Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches) Approved by Factory Mutual Research Corporation (maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E The Upright Sprinkler without an Escutcheon (TY3135) is available in I inch NPT Only * Light and Ordinary Hazard occupancies only ** Light Hazard occupancies only TABLE B 1 INCH NPT (AND ISO 7-R 1) SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP5IO Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FIUING ORDER LENGTHS: 2-3/4 to 48" 1-3/4' DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4(6,4 mm) INCREMENTS FACE OF CEILING 2-3/16±1/8' 3" DIA. (55,6 ± 3,2 mm) - (76,2 mm) FIGURE 3 PENDENT TY3235 AND TY3935 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4' to 48' (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4' DIA. INCREMENTS (57,2 mm) F OF ACE .1j, , CEILING mm) FIGURE 4 PENDENT TY3235 AND TY3935 WITH RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FIlliNG ORDER LENGTHS: 3-1/2' DIA 1/2 to 46" (88,9 mm) (12,7t01168,4mm) IN 1/4° (6,4 mm) 2-1/2 DIA INCREMENTS (6 3,5 FACE OF CEILING 4-1/4'± 1/8 (108,0±3,2 mm) FIGURE 5 PENDENT TY3235 AND TY3935 WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5" to 48 (127,0 to 1219,2 mm) IN 1/4 (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT TY3235 AND TY3935 WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5' to 48" (127,0 to 1219,2 mm) IN 1/4° (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT TY3135 WITHOUT ESCUTCHEON 1 INCH NPT ONLY SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 1-314 UIPI. (44,5 mm) CENTERLINE OF WATERWAY 3" DIA. (76,2 mm) 5/16" (7,9 mm) FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2 to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 4-1/4" ± 1/8" ' 2-1/2" DIA. FACE OF - (108,0 ± 3,2 mm) FACE OF (63,5 mm) fl MOUNTING SPRINKLER FITTING I JSURFACE SPRINKLER FITTING !77 (88,9 mm) 3-1/2" DIA. (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS FACE OF I- SPRINKLER FITTING MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE TFP5IO Page 5 of 10 ORDER LENGTHS: 2-3/4 to 48" (69,9 to 1219,2 mm) IN 1/4 (6,4 mm) INCREMENTS 2-3/8" ± 1/8 (60,3 ± 3,2 mm) The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of the 1 inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249) For wet pipe system installations of the the 3/4 inch NPT Series DS-1 Sprin- klers connected to CPVC piping, use in the 3/4" x 3/4" NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry-Type Sprin- klers and the branch line. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install the Series DS-1 Dry-Type Sprinkler into any other type fitting without first consulting the Technical Services Department Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON TFP5IO Page 6 of 10 FACE OF SPRINKLER - - FITTING EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES 77ulci FIGURE 11 EXPOSURE LENGTH STRAP TIES J (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE f 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER TO WET SIDE SYSTEM OUTLET PLUGGED cm DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) FIGURE 12 SPRINKLER FITTING HEATED AREA 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE I STRUCTURE DSB-2 BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE SYSTEM DESIGN CRITERIA SECTION) I DSB-2 INTENDED FOR FREEZER STRUCTURES ThJL"1it FIGURE 13 SPRINKLER FITTING UNHEATED AREA WRENCH RECESS WRENCH I FLAT 0120 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 16 W-TYPE 7 SPRINKLER WRENCH Temperatures for Heated Areal 40°F I 50°F I 60°F Ambient Temperature Exposed to (4°C) (10°C) (16°C) Discharge End of Sprinkler Minimum Exposed Barrel Length2, Inches (mm) 40°F 0 0 0 (4°C) 30°F 0 0 0 (-1°C) 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) 1 (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TFP5IO Page 7 of 10 Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin- kler Boot, described in Technical Data Sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Installation The TYCO Series DS-1 Dry-Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be installed in accordance with this section. General Instructions The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 286°F (141 °C) rating. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright position. The deflector of a pendent or upright sprinkler must be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their cen- terline of waterway perpendicular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 2. With a non-hardening pipe- thread sealant such as TEFLON tape applied to the Inlet threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Ref. Figures 1 and 2) the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 16) Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. TFP5IO Page 8 of 10 Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry-Type Sprin- klers, 5.61K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figures 1 and 2) to indicate if the Dry-Type Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage (e.g., an improper installation or an ice plug). Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). DS-1 Dry-Type Sprinklers When ordering TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Stan- dard Coverage, specify the following information: SIN: Pendent - TY3935 or TY3235 Sidewall - TY3735 or TY3335 Upright - TY3135 5.6 K-factor Deflector Style: Upright, Pendent, or Horizontal Sidewall Quick Response, Standard Cover- age, Dry-Type Sprinkler Order Length: Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10. After taking the measurement, round it to the nearest 1/4 inch increment. Inlet Connections: 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 Temperature Rating Sprinkler Finish Escutcheon Style and Finish, as applicable Part Number (P/N) from Table D The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only. Part Numbers are for 3/4 in. and 1 in. NPT standard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhesive (a sufficient quantity for installing one boot). TFP5IO Page 9 of 10 P/N*60_ XXX- X- XXX F- SIN H 01 Pendent with Standard TY3935 Escutcheon (3/4° NPT) (Figure 3) 02 Pendent with Deep TY3935 Escutcheon (3/4 NPT) (Figure 5) 03 Pendent with Recessed TY3935 Escutcheon (3/4° NPT) (Figure 4) 04 Pendent without TY3935 Escutcheon (3/4° NPT) (Figure 6) 05 Sidewall with Standard TY3735 Escutcheon (3/4 NPT) (Figure 8) 06 Sidewall with Deep TY3735 Escutcheon (3/4° NPT) (Figure 9) 07 Sidewall without TY3735 Escutcheon (3/4' NPT) (Figure 10) 36 Pendent with Standard TY3235 Escutcheon (1° NPT) (Figure 3) 33 Pendent with Deep TY3235 Escutcheon (1" NPT) (Figure 5) 37 Pendent with Recessed 1Y3235 Escutcheon (1 NPT) (Figure 4) 32 Pendent without TY3235 Escutcheon (1" NPT) (Figure 6) 34 Sidewall with Standard TY3335 Escutcheon (1° NPT) (Figure 8) 43 Sidewall with Deep TY3335 Escutcheon (1° NPT) (Figure 9) 44 Sidewall without TY3335 Escutcheon (1° NPT) (Figure 10) I SPRINKLER ESCUTCHEON FINISH FINISH1 0 CHROME PLATED SIGNAL WHITE (RAL9003) 1 NATURAL BRASS SIGNAL WHITE (RAL9003) 2 NATURAL BRASS BRASS PLATED SIGNAL WHITE SIGNAL WHITE (RAL9003) (RAL9003) 9 CHROME PLATED CHROME PLATED I TEMPERATURE RATINGS 0 135-F (57-C) 1 155°F (68°C) 2 175-F (79-C) 3 200°F(93°C) 4 286°F (141°C) 055 082 180 187 372 480 SAMPLE I ORDER LENGTHS2 5.50" 8.25" 18.00" 18.75" 37.25" 48.00" Notes: Escutcheon Finish applies to sprinklers provided with escutcheons. Dry-Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. Use Prefix °l" for ISO 7-R 1 Connection (e.g., 1-60-010-4-055). 38 Upright without TY3135 Escutcheon (1" NPT) (Figure 7) TABLED SERIES DS-1 DRY-TYPE SPRINKLERS PART NUMBER SELECTION