Loading...
HomeMy WebLinkAbout1944 KELLOGG AVE; ; FPC2020-0185; PermitPERMIT REPORT (Laty of Carlsbad Print Date: 12/07/2020 Job Address: 1944 KELLOGG AVE. CARLSBAD, CA 92008-6581 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120922900 Track #: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check U: Permit No: FPC2020-0185 Status: Closed - Finaled Applied: 10/22/2020 Issued: 11/02/2020 Finaled Close Out: 12/07/2020 Inspector: Final Inspection: Project Title: Description: BDR COMMUNICATIONS -REPLACE FIRE ALARM CONTROL PANEL, ADD CELLULAR COMMUNICATOR, CONNECT DEVICES Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC ROBERT HAUl P0 BOX 3042 3870 MURPHY CANYON RD, U STE 140 BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-4403 (561) 226-8210 (858) 243-4901 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 1 I www.carlsbadca.gov 9tZom -5 Project: BDR Communications 1944 Kellogg Ave. Carlsbad, CA 92008 Sprinkler Monitoring System Replacement Contractor: Johnson Of(# Controls 3870 Murphy Canyon Rd Ste. 140 San Diego, CA 92123 Contact: Robert Haut 858-243-4901 1111:,, , t% G-cRtCAC. I4*4 O CLASSIFICATION — z 12 c-la J) LICENSE No. -i& 977249 Honeywell Home Control Panels VISTA-12 8FBPT VISTA7 Commercial PartitiOned Fire and Bu rglary AlarrrY COntrol Panel The VISTA-128FPT provides the ultim ate protection for Life and property, This commercial fire and burglary control pa net supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V-Plex addressabletechnologies. A diverse Line of Honeywell Home initiating devices, hotification appLiances, communication devices, keypads, RF receivers and relays satisfy a.wide range of installation requirements. and synagogues, banks, schools, strip mall and factory or warehouse environments. The VISTA-128F9PT control is suitable for fire-only applications, as welt as foiñstallations requiring i ntegrated fire/burglary systems. Itis the perfect solution for medical and professional office buildings, churches VISTA-12F8PT is compatible with a number of Alarm Net@ comm unication products for alarm reporting, uploading! downloadi no and ResldeoTotal Connect Remote Services. i—ri nrc' !_c_&II .r-tL3 a Eight hardwired zones standard, expandable to 120 V-Plex add ressable points/zones or 128 wireless points/zones Supports upto 128 wireless zones (fewer if using hardwired and/or V-Plex zones) a Can control eight separate areas independently (8 partitions) + Common Lobby partition -auto arm or disarm based upon assigned partitions Master partition - used for viewing status of alipartitions Supports commercial wirelessfire and burglary devices Stores up to 512 events Accommodates 150 user codes and upto 250 access card holdersusing VI STAKE Supports V-Plex addressable VISTAKEY access control (ito B doors) Two on-board NACS delivering a total of2.3Ai2V 'Automatic smoke detector sensitivity maintenance testing* Four-wire smoke reset using on- board Form Crelay Supports Dynamic Signaling for AlarmN eCorn municators Supports Internet and GSM alarm reporting Supports graphical user interfaces for burglary use (e.g. 6280 and Tuxedo Touch") 'Supports 6160cP-2 multi-LED fire keypad cyvif via Alarm Net Communicators Carbon monLlde (CO) zone support On-board serial port for communication with WIN-PAK, Pro-Watch'and approved third party applications Supports Tota t Connect Remote Services* * Ent report ing on FMforfire partition. VISTA-i 28 FBPT VISTAS Commercial Partitioned Fire and Burglary Alarm Control Panel ADDITIONAL FEATURES Notification Appliance Circuits (two): - Programmable - Individuallysilenceable False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning -Call waiting defeat - Recent close report Supports commercial hardwired, addressable V-Plex7 polling loop and wireless zones Hardwired zones - Provides eight style B .hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.C. or N.0 sensors - Individually assignable to any of eight partitions (all fire zones on partition 1) - Up to 16 two-wire smoke detectors each on zone one and two (32 total) Patented addressable V-Ptex polling loop technology - Class B, Style 3 SLC - Supports 120 two-wire addressable points - Global polling technology for faster processing - Supervised by panel - Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay - 4,000 ft. capability without the use of shielded cable - Extender/Isolation bus modules - Eight zone - ClassA and 8 expander module - Eight zone - Class B expander module - Single-zone supervised contact module - Single relay module for auxiliary fire functions - Supports anti-masking feature on 'smart" motion detectors (e.g, DT7500SN) UL Listed wireless expansion - Supports up to 128 wireless zones/points - Supervised bycontrolfor check-in signals - Tamper protection for transmitters Individually assignable up to eight partitions - Supports commercial wireless smoke detectors Up to eight doors using VISTAKEY® V-Plex Access Control Event reporting Local printer for event log printing Communication - Phone line. GSM and IP communicator support - Panel operation during download - Four or 10-digit subscriber account numbers Extra security feature that requires master code to allow installer into program mode (enabled through Compass Downloader) VISTA-128FBPT VISTA Commercial Partitioned Fire and BurglaryAlarm Control Panel SPECIFICATIONS Electrical: Primary power: 18VAC @ 7 2V Honeywell Home No. 1451-UL9 Control panel quiescent current draw: 300mA Backup battery: 12VDC, 12AH min to 34.44H max Lead acid battery (gel type) Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3Al2V Aux. standby pwr: 12VDC, 1A max Total power: 2.3A at 12VDC Standby time: 24 hours with 14 standby load using 34.44H battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors All outputs are power limited. Optional 24-volt kit Communications Dialer: Line seize: Double Pole Ringer equiv: 0.7 B Formats: AD EM CO* Low Speed, ADEMCO4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Backup Communication: Dual phone line capability using 5140DLM module AlarmNet® Communicators: GSM, i-GSM and IP Communicators Cabinet Dimensions: 18 H x 14.5Wx4.3D Environmental: Storage temp: 14°F to 158°F (-10°C to 70°C) Operating temp: 32°F to 122°F (0°C to 50°C) Humidity: 85°Io RH EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - lEC EMC Directive Agency Listings: UL864/NFPA72 Local, Central Station and Remote Station ULC-5559-04 -Equipment for Fire Signal Receiving Centers and Systems UL1076 - Proprietary Burglar Alarm Units and Systems UL1610—Central Station Burglar Alarm Units CAN/U LC-S304-06 - Signal Receiving Centre and Premise Burglar Alarm Control Units UL1635— Digital Alarm Communicator System Units UL365 - Police Station Connected Burglar Alarm Units and Systems UL609-. Local Burglar Alarm Units and Systems UL985 - Household Fire Warning System Units UL1023 - Household Burglar Alarm System Units ULC-5545-02 - Residential Fire Warning System Control Units ULC/0RD-C1023-74— Preliminary Standard for Household Burglar Alarm System Units ULC-5303-M91 —Standard for Local Burglar Alarm Units and Systems Factory Mutual (FM) California State Fire Marshal (CSFM) FDNY Certificate #6140 COMPATIBLE DEVICES Auxiliary Devices 4190SN Remote Point Module - 6160CR-2 - Red Fire Keypad two zones 4193SN and 4193SNP Two-zone 6160— Burglary Keypad Expander Modules 6280, Tuxedo Touch, Tuxedo Touch V-Plex Extender/Isolation Modules with Wi-Fi Graphic Keypads - Burglary 4297 Extender/Isolator Module 4204— Relay Module, four Form C VSI Isolator Module contacts 4204CF - Two supervised NAC circuits 5881ENHC Series RF receivers 5883H RF receiver 6220S— System printer Two-Wire Smoke Detectors Conventional System Sensor ESL DSC Horn/Strobes System Sensor Wheelock G entex Manual Pull Stations 5140M PS-i 5i40M PS-2 V-Plex (Addressable) Devices 4208U Universal Eight-zone Expansion Module 4208EX Universal Eight-zone Expansion Module (Canada) 42085N Eight-zone Expansion Module 4101SN Single Relay/Zone Module 42085NF Class A/B Expander Module V-Ptex Smoke Detectors 51935D 5193SDT 5193SDTA V-Plex Passive Infrared Detectors IS2500SN DT7 500SN V-Plex (Addressable) Contacts 49395N-WH 49595N V-PLex Glassbreak Detectors FGI62SSN Seismic Detectors SCiOO SC1OS Commercial Wireless Devices 5808W3/5808W3A- Photoelectric Smoke/Heat Detector 5806W3 - Photoelectric Smoke Detector 5809 - Wireless Heat Detector 5817C8 - Wireless Commercial Transmitter 5869- Hold-Up Transmitter ORDERING V128FBPT Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBPT24KT Commercial Fire and Partitioned Burglary A[arm Control Panel with External J.S. Only) 24V Power Supply (13A four outputs, synchronized) For more information security.honeywellhom e.com Resideo Technologies, Inc. 2 Corporate Center Drive, Suite 103 P.O. Box 9040 Melville, NY 11747 1-800-645-7492 resideo.com Atttrademarks are property of their respective owners LJVSI28FBPTO/D I 11119 Cli) 2019 ResideoTechnotogies Inc This product is manufactured by Resideo and its affiLiates. The koneywett Home trademark is used under license from Honeywell. International Inc. All rig hts reserved. VISTA-128FBPT VISTAS Commercial Partitioned Fire and Burglary Alarm Control Panel 580000/580000A - Carbon Monoxide Detector 5800P1R-COM - Commercial PIR Access Control VISTAKErV-Plex (addressable) Access Control VISTAKEY-SK Starter Kit VISTA KEY-EX Expansion Kit Integrates with WIN-PAK and Pro-Watch systems Alarm Communications U.S. GSMV4G - Digital Cellular Communicator with Two-way Voice Transport Capability iGSMV/iGSMV4G - Internet and Digital Cellular Communicator iGSMCF/iGSMCFP4G - Commercial Fire Digital Cellular Communicator with Internet iGSMHS/iGSMHS4G - High Security Internet and Digital Cellular Communicator 7845i-ENT - Internet/Intranet Enterprise Communicator 78471 - Internet Communicator Canada GSMV4GCN - Digital Cellular Communicator with Two-way Voice Transport Capability iGSMVCN/iGSMVCN4G - Internet and Digital Cellular Communicator Product specifications subject to change Honeywell Home CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1645:0197 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: ADEMCO INC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawadHoneywell.com DESIGN: Models Vista-32FBPT, Vista-128FBPT, Vista-250FBPT, *C250F *TYCMSM250 FA1670CT and FA1700CT control units. Suitable for local, remote station, proprietary and central station applications. Minimum system configuration may include any of the following components: SAVISI00-24;Main Board 1451 Transformer COM-UL; Enclosure 700-00709-02; Enclosure(for use with Vista-32FBPT) 6160CR-2;Alpha Keypad (for use with Vista series) FA570CR;Alpha Keypad (for use with First Alert series) ECP; Isolator 4146;Keyswitch 5I400LM;Dialer Module 7845i-ENT; Internet Communicator 4208U ; Remote Conventional Zone Expander 4208SNF V-Plex Class A Adapter Vplex VSI; Short Isolator 4204CF;Supervised 41905N; Expansion Module 4193;Serial Number Interface Module 4297;Polling Loop Extender 5881 ENHC, 5883-H;Short Range RF Receiver For additional accessories and devices refer to the manufacturer's installation instructions. RATING: 120 Vac, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. *Rev 11-04-15gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7165-1645:0197 Page 2 of 2 NOTE: Burglary and other non-fire functions were not examined. *Rev 11-04-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other, data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 6160CR-2 COMMERCIAL FIRE ALPHA KEYPAD UL864 REV 9 LISTED The 61 6OCR-2 is an addressable remote keypad intended for use in commercial fire applications with Honeywell's commercial fire control panels. The keys are continuously backlit for convenience and easy visibility. The LCD display FEATURES is backlit only when a key is depressed*, or when the system is in alarm or trouble condition. *Note. The LCD may be programmed to remain on at all times (see panel instructions for details). Four programmable function keys Built-in sounder Seven Status LEDs - Armed (Red) - Ready (Green) - Power (Green) - Fire Alarm (Red) - Silenced (Yellow) - Supervisory (Yellow) Trouble (Yellow) Large easy-to-read display Red removable door Physical 5.250" W x 7.437" H x 1.312' D SPECIFICATIONS Sounder High-quality speaker Electrical 45mA standby 1 60mA in alarm (sounder, back light and LED on) Compatibility Supports Control Panels - VISTA-32FB Rev 5 and higher - VISTA-1 28FBP Rev 4 and higher - VlSTA-250FBP Rev 4 and higher UL/CUL and residential Listed for commercial fire and burglary installations. To be employed with manufacturer's listed control units as indicated in the installation instructions. Product specifications subject to change. ORDERING 6160CR-2 Commercial Fire Alpha Keypad For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com LJ6160CR2o/D September 2009 0 2009 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0115 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: ADEMCO lNC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawadresideo.com DESIGN: Models 6139, 6139R, 6160VADT, 6160V, 6270, 6270ADT, FA700KP, 6160CR, 6150V, 6I50VADT, CPI50KP, FA560VKP, FA615OKP-GP, 6160VBAY, 6164, 61645P, 8132i, 8142i, FA800KPi, FA850Kpi, 6270PL2, 6271V, 6271 VADT, FA270VKP, FA570VKP, FA270KP, FA570KP, FA574KP, 6271 C, 6271 CV, FA701CKP, FA701CVKP, FA701VKP, FA570CR, 6160CR-2, 6164U5, FA27IKP, 6149EX, 6165EX remote keypads, 4146 keyswitch, and *6280s *6280w *TUXS *TUXW touchscreen keypads. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, UL and ETL label. APPROVAL: Listed as remote keypads for use with listee's separately listed compatible fire alarm control units. Refer to listee's installation Instruction Manual for details. rev. 09-23-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM $ SENSOR® Photoelectric Smoke Detectors System Sensor series smoke detectors represent significant advancement in conventional detection. The J3 family is founded on three principles: installation ease, intelligence, and instant inspection. t Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & LISTED <~> 0 MEA MSFM APPROVED approved approved AVU8 5911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors.To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the j3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The j3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 1j Smoke Detector Specifications Smoke detector shall be a System Sensor il Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 u maximum average; 4-wire: 50 qA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24V Peak Standby Current 2-wire: 100 qA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height. Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble . 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every S seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20 mA@ 12V,23 mA@ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter SY'STEA7 3825 Ohio Avenue. St. Charles, IL 60174 2OOgSYst&nSeeSO, P,oductspec,tcat,ons subject to change without notice. Visit systen'oensor.com to, 5ff J5Q° Phone: 800-SENSOR2 . Fax' 630-377-6495 current productinfcrrnaton, including the latest version of this data sheet. A05-0318-007 .6/09.#2t69 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE fl~qj LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 2W-B, 2W1-B, 4W-B and 4W1-B photoelectric type smoke detectors. Models 2W-B and 2W1-B are 2-wire and model 4W-B and 4VVT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Honeywell Home Alarm Communications LiG LTE+IP LIE and Internet Multi-Path Communicators Honeywell Home is focused on providing the best alarm communication solutions for the security industry. Alternative communication methods are critical in the marketplace due to inconsistencies in VoiP, migration from POTS and the evolution of cellular networks. LTE network connectivity provides the longest viable cellular lifespan available. All sig nals are delivered to the AlarmNet' Network Control Center, which routes the information to the appropriate central station. The state-of-the-art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery. Honeywell Home End-to End Solutions 0criONS Sensors LTE+IP Control WO Communications Panels DEALERS w LU co 2\\ One -Stop AlarmNet 360 j -\\ Support Totat Connecr - OlNG suPPO s$o FEATURES LeG LTE network and I compatibility . Fu IL Contact ID Contact ID reporting using ECP mode with compatible Honeywell Home control panels. .256-bit AES Encryption Advanced encryption standard used for secure communications. Upload/DownLoad Available with select Honeywell Home control panels. Requires Compass version 1.5.8.54a or higher. Diagnostic LEDs Provide signal strength and status indications. QOS Quality of Service diagnostics via AlarmNet supply vital information including when a message was received, battery voltage, input voltage, signal strength and message path. ALarmNet360 Online Management Platform Remote programming and diagnostics to improve business efficiencies and reduce truck rolls. www.alarmnet360.com Remote Services Capability* Optional Resideo Total Connect Remote Services - Boost RMR while providing on-the-go security and home control, video viewing, and real-time alerts, anytime, anywhere, on any PC or smart device. FOTA Firmware Upgrading Complete over-the-air firmware upgrading capability. Provides remote service management ability. Dual Technology Reporting Provides I P and cellular transmission paths with added flexibility and reliability. (LTE-IV, LTE-IA, LTE-IC) Six Input Zones Used for universal control panel compatibility. (LTE-IV, LTE-IA, LTE-IC) Built-in Power Supply! Backup Battery On-board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. 6V 3.1Ah battery supplied to deliver up to 24 hours of standby operation. *Service subscription required. SPECIFICATIONS VISTA 4G LTE Multi-Path Communicators (LTE-IV/LTE-IA/ LTE-IC) VISTA 4G LTE Multi-Path Communicators (LTE-CFA/LTE-CFV) Multi-path IP and Cellular Technologies DESCRIPTION Integrated VISTA ECP design LTE CAT1 PANEL COMPATIBILITY All VISTA® controls with ECP radio support. Universal panel compatible using zone inputs. DIMENSIONS 8.4"x 8.0"x 1.5" (2 1.3cm x 20.3cm x 3.8cm) Input Power: 16.5VAC, 40VA transformer, ELECTRICAL Model No. 1361 Backup Battery: 6V, 3.IAH RF Antenna: Internal Penta-Band antenna with receive diversity for LTE CATI. Average 3.8dBi gain. Operating Temperature: -41 to 131° F (-201 to 55° C) ENVIRONMENTAL Storage Temperature: -400 to 158° F (-401 to 70° C) AGENCY LISTINGS ETL Listed DESCRIPTION Commercial Fire Internet and LTE Communicator PANEL COMPATIBILITY VISTA-32F8, VISTA-32FBT, VISTA-I28FBP, VISTA-128FBPT, VISTA-250FBP, VISTA-2508PT. DIMENSIONS 15.0"H X12,75"Wx3.0"D I2VDC supplied by the control panel ELECTRICAL 90mA Standby, 105Ma active Frequency Peak Gain (dBi) Radiation 698 to 960 MHz 0.84 to 1.09 Omni-directional RF 1710 to 2170 MHz 1.81 to 1.87 Omni-directional Operating Temperature: 0°Cto49°C ENVIRONMENTAL Storage Temperature: -400 to 158° F-40° Cto 70° C AGENCY LISTINGS UL864 1011 Edition, CSFM VISTA 4G LTE Multi-Path Communicators (LTE-HSV) I SPECIFICATIONS DESCRIPTION High Security Internet and Cellular Communicator PANEL COMPATIBILITY VISTA® Control panels with ECP radio support. Universal panel compatible using zone inputs DIMENSIONS 8.4" x 8.0" x 1.5" (21.3cm x 20.3cm x 3.8cm) Input Power: 16.5VAC, 40VA transformer, ELECTRICAL Backup Battery: 319mA Standby, 380Ma active RF Antenna: Internal Penta-Band antenna with receive diversity for LTE CATI Average 3.8dBi gain. Operating Temperature: ENVIRONMENTAL -41to1311 F(-20° to 55° C) Storage Temperature: -40° to 158° F (-40° to 70° C) AGENCY LISTINGS UL365, UL1610, Encrypted Line Security, NIST ORDERING U.S. Canada LIE-IA LTE-IV LTE-CFA/ LIE-CFV AT&T Verizon AT&T! Verizon VISTA-15P VISTA-20P VISTA-I28BPT VISTA-250BPT (universal panel compatibility using zone inputs) VISTA-15P VISTA-20P VISTA-I28BPT VISTA-250BPT VISTA-32FB VISTA-32FBT VISTA-I28FBP VISTA-I28FBPT VISTA-250FBP VISTA-250BPT IGSMV4G GSMX4G/CDMA-X IGSMCFP4G VISTA-I5PCN VISTA-20PCN VISTA-I28BPTCN LIE-IC Bell VISTA-250BPTCN IGSMV4G (universal panel compatibility using zone inputs) LTE-HSV Verizon VISTA-15P VISTA-20P VISTA-I28BPT VISTA-250BPT (universal panel compatibility using zone inputs) IGSMHS4G For more information security.honeyweLlhome.com r resideo Resideo Technologies, Inc. 2 Corporate Center Drive, Suite 100 P.O. Box 9040 MeLviLle, NY 11747 1-800-645-7492 resideo.com L/LTEIMPCD/D I 07/19 2019 Resideo Technologies, Inc. This product is manufactured by Resideo and its affiliates. The Honeywell Hornetrademark is used under license from Honeywell International Inc. ALL rights reserved. Honeywell Home CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ~[im OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0509 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: ADEMCO INC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com DESIGN: Models LTE-CFA (AT&T) and LTE-CFV (Verizon) Commercial Internet and LTE Communicator. The unit uses the Internet as its primary reporting path, and switches to cell service (secondary path as backup) when the Internet is not available. Refer to listee's product specification data sheets and installation, operation, and maintenance manual for detailed product description and operational considerations. RATING: 12VDC (supplied by the Control Panel) 90 mA standy 160 mA active INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible commercial fire alarm control units. Intended for use with specific Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. 05-28-2019 dcc TO This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division