Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; FA080029; Permit11/3/21, 12:32 PM FA080029 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA080029 Job Address: 2200 FARADAY AV Status: ISSUED Permit Type: FALARM Applied 5/9/2008 Parcel No: 2121204100 Approved: 5/27/2008 Lot #: 0 Reference No.: Issued: 5/27/2008 PC #: Inspector: Project Title: CATALINA RESTAURANT GROUP TI FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: DIVERSIFIED PROTECTION SYSTEMS D L FARADAY L P C/O DRA ADVISORS LLC 220 E 42ND ST #27 1241 NORTH BARSTEN WAY NEW YORK NY 714-632-0929 Fees ($) 1.Add'I Fees ($) Total ($) Balance ($) 125 0 125 I 0 1/1 FAO'S oo2-j [Z> tco E - I DIVERSIFIED PROTECTION SYSTEMS INC Equipment Submittal Building Life Safety System For: Catalina Restaurant Group 2200 Faraday Avenue Carlsbad, Ca 92008 A PP RO ITTE D e&*A7j CARLSBAD VIREI DEPARTMENT DPSI Job #1778 May 7, 2008 1241 NORTH BARSTEN WAY 4580 ENTERPRISE STREET ANAHEIM, CA 92806 I I FREMONT, CALIFORNIA 94538 WEB: WN.DPS-SC.COM I PHONE: 714*632O929 I CA. LIC. #703883 I PHONE: 510-490-7766 FAX: 714-632-0930 I FAX: 510-490-7767 lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. lntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description 5700 performs drift compensation and calibration checks on each of the sensors in the system. The basic lntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Up to 50 addressable points Up to 125 zones and 125 output groups Uses standard wire—no shielded or twisted pair required Built-in digital communicator. Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Distributed, intelligent power Drift compensation 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5A at 27.4 VDC Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power-limited Standby Current: 200 mA Alarm Current: 325 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Mechanical Specifications Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Model 5700 Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:144; MEA429-92-E Vol. XVI. D SILENT KNIGHT I by Honeywell fl 1 5113 'a3MOboy1Ulltl — I L4 4 J____ -J 5496 MADE IN AMERICA FORM# 350392 Rev. D, 04/06 Copyright © 2006 Silent Knight SLC Detectors SD505-APS Addressable photoelectric smoke detector. SD505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F-150°F (0°C-37°C). SD505-6AB Six inch base for use with detector heads SD505-APS, SD505-AIS and S0505-AHS. SD505-4AB Four inch base for use with detector heads SD505-APS, SD505-AIS, and 5D505-AHS. SD505-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61B Short circuit isolator base for 5D505-AHS, SD505-APS, and SD505-AIS detectors. SD505-6RB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-ADH Duct housing that detects smoke in HVAC ducts. 5D505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and SD505-AIS sensors. Compatible with 5D505-DTS remote test switch. SD500-PS/SD500-PSDA SD500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules Model SD500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500-MIM Mini dry contact input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SD500-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500-SDM Two-wire detector input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500-LEDs can be used per system. S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-ADHR. U I I I I E., I CO - WIll-US 1C5l5.A?I 1D*l$.11ll WSOI.CTS -- - 5DIlS.D$ll 8DSOO.P5 5OIlIO$ WIll- 1111 5Dsll,ARM Pd5 51. -- -.- 5700 DSILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0559:144 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models *IFp..50 and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: RATING: IFP-50, 5700 7628 5860/5860R1RA-1000 5897 5496 5824 5865-3/5965-4 5880 5883 SD500-LIM 5D505-61 B RA-100 3158 5220 120 VAC Primary, 24 VDC Secondary Control Units EOL Resistor Annunciator Power Supply *Notification Power Expander Serial/Parallel Interface LED Annunciator LED 10 Module Relay Interface Board Line Isolation Module Isolation Base Remote Annunciator Reverse Polarity Module Direct Connect Module INSTALLATION MARKING In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE- 360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912- 1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911- 1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 81h Edition Standards Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *ReceWRev. 08-17-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 5, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager 1 _______ ____ - - __.4• --..- ,45.. ______________ .4 .-.-- - ' - .-,.,. 1.1 ._ - - , 4----.- - -.. - I I Rechargeable Sealed Lead-Acid Batteries Model Nominal Nominal Voltage V Nominal Capacity@ A.H. Current @ 20 hr. rate mA Length Width Height Ht. Over Terminal Weight Standard Terminals in. mm in. mm in. mm in. mm lbs. kgs. PS-260 2 6.0 300 1.97 50 1.34 34 3.94 100 4.13 105 0.90 0.41 Fl PS-445 4 4.5 225 1.89 48 2.09 53 3.70 94 3.86 98 1.40 0.64 F2 PS-490 4 1 9.0 450 3.97 101 1.73 44 3.74 95 4.02 102 2.80 1.27 F2 PS-4100 4 10.0 500 4.02 102 1.97 50 3.72 94 3.92 100 3.10 1.41 Fl PS-605 6 0.5 25 2.24 57 0.55 14 1.97 50 1.97 50 0.20 0.09 WL PS-610 6 1.0 50 2.00 51 . 1.65 42 2.00 51 2.20 56 0.60 0.27 Fl PS-612 6 1.3 65 3.82 97 0.94 24 1 2.00 51 2.19 56 0.60 0.27 Fl PS-628 6 2.8 140 2.60 66 1.30 33 3.86 98 4.06 103 1.25 0.57 Fl PS-630 6 3.0 150 5.28 134 1.34 34 2.35 60 2.56 65 1.50 0.68 Fl PS-632 6 32 160 2.60 66 1.30 33 4.65 118 4.80 122 1.50 0.68 Fl PS-640 6 4.5 225 2.76 70 1.89 48 4.02 102 4.25 108 1.95 0.89 Fl PS-650L 6 5.0 250 2.63 67 2.63 67 3.78 96 428 109 2.00 0.91 SP PS-665 6 6.5 325 3.86 98 220 56 4.05 103 4.05 103 3.00 1.36 FP PS-670 6 7.0 350 5.95 151 1.34 34 3.70 94 3.86 98 3.00 1.36 Fl PS-682 6 8.0 400 3.86 98 2.20 56 4.65 118 4.65 118 3.30 1.50 Fl PS-6100 6 12.0 600 5.95 151 2.00 51 3.70 94 3.86 98 4.60 2.09 Fl or F2 PS-6120 6 12.0 600 4.26 108 2.75 70 5.54 141 5.54 141 520 2.36 FP PS-6120Toy 6 12.0 600 4.26 108 2.75 70 5.54 141 5.54 141 520 2.36 TSorTH PS-6200 6 20.0 1000 6.18 157 3.27 83 4.92 125 4.92 125 820 3.73 NB PS-6360 6 36.0 1800 6.25 1 159 3.35 85 6.50 165 6.95 177 113.80 6.27 F2orNB PS-832 8 32 160 5.28 134 1.42 36 2.49 63 2.70 69 1 1.90 0.86 Fl PS-1208 12 0.8 40 3.78 96 0.98 25 2.42 62 2.42 62 0.80 0.36 WI. PS-1212 12 12 60 3.82 97 1.65 42 2.00 51 2.13 54 1.30 0.59 Fl PS-1220 12 2.2 110 7.01 178 1.34 34 2.36 60 2.56 65 1.90 0.86 Fl PS-1223 12 2.3 115 7.17 182 0.94 24 2.42 62 2.42 62 1.76 0.80 PC PS-1229 12 2.9 145 7.01 178 1.34 34 2.36 60 2.56 65 2.20 1.00 Fl PS-1230 12 3.0 150 5.23 133 2.64 67 2.36 60 2.60 66 2.60 1.18 Fl PS-1250 12 5.0 250 3.54 90 2.75 70 4.01 102 420 107 420 1.91 Fl or F2 PS-I 270 12 7.0 350 5.95 151 2.56 65 3.70 94 .3.86 98 5.702.59 F1orF2 PS-1282 12 8.0 400 3.86 98 4.40 112 4.65 118 4.65 118 6.703.05 Fl PS-12100 12 12.0 600 5.95 151 4.00 102 3.70 94 3.86 98 9.204.18 F1orF2 PS-1 2120 12 12.0 600 5.95 151 3.86 98 3.70 94 3.94 100 9.004.09 F2 PS-12180 12 18.0 900 7.13 181 2.99 76 6.57 167 6.57 167 13.105.95 F2orNB PS-12260 12 26.0 1300 6.55 166 6.88 175 4.95 126 4.95 126 20.809.45 F2 or NB PS-12280 12 28.0 1400 6.54 166 4.95 126 6.89 175 6.89 175 20.809.45 NB PS12330* 12 33.0 1650 7.70 196 5.19 132 6.10 155 7.00 178 24.0010.91 NBorB PS-12400 12 40.0 2000 7.75 197 6.50 165 6.75 172 6.75 172 32.2514.70 NB PS-125504 12 55.0 2750 9.04 230 5.45 138 8.15 207 8.98 228 41.1018.68 NBorB PS-12750 12 75.0 3750 10.25 260 6.60 168 8.15 207 8.98 228 54.7024.86 NBorB PS-121000 12 100.0 5000 12.00 305 6.60 168 8.15 207 8.98 228 65.70 2986 NBorB *Also available with handle. To order, add "H to model number. Note: for 12550H, 12750H and 1210001-1 overall length increases. The PSG Series of batteries are models which corresoond in size to Gates (Hawker-Sidlev) batteries of the same size and capacity: PSG-450 4 5.0 250 3.54 90 1.94 49 2.87 73 2.87 73 1.70 0.77 F2 PSG-480 4 8.0 400 3.54 90 1.94 49 4.00 102 4.00 102 2.50 1.14 F2 PSG-625 6 2.5 125 4.15 105 1.63 41 2.70 69 2.70 69 1.50 0.68 Fl PSG-650 6 5.0 250 5.28 134 1.94 49 3.00 76 3.00 76 2.50 1.14 F2 PSG-680 6 8.0 400 5.28 134 1.94 49 3.99 101 3.99 101 3.70 1.68 F2 I I I I [1 U I I I LI I I I I I I I "Fl" FASTON Spring "SP" 0.187 x 0.032° m Fully collapsible spring quick disconnect terminals for positive tabs. fi and negative contacts. "F2" FASTON 0.250' x 0.032° quick disconnect tabs. "FP" FASTON Polarized Positive: °F2° Negative: "Fl" Nut&Bolt "NB" Terminal post (lead alloy or tin-plated brass) Button "B" "PC" Pressure Contacts Threaded insertion On PS-1223 battery. terminal "WL" Insulated, stranded wire leads terminated with: Molex Housing 5264-02 & 5263-PBT plug on PS-605 AMP Housing 1-480318-0 & 8116-1 on 1208 I "TS/TH" Toy battery connectors: 6120 TS 6120TH I S-connector 'i!lluIJ.: • H-connector All data subject to change without notice. I Characteristic Discharge Curves Effect of Temperature on Capacity 120 6.5 13 ---.005C 100 6.0 12 > ) 5.51-11 80 Cs m 60 co . 40 0 20 0 -20 -10 4.0 8 n 1 2 3 5 10 20 30 60 2 3 5 10 20 30 I. mm -1 h Discharge Time © 20°C (68°F) 0 10 20 30 40 50 60 Temperature (°C) Cycle Applications: Limit initial current to 0.30C (C is the nominal A.H. capacity of the battery). Charge until battery voltage (under charge) reaches 2.45 volts per cell at 68°F (20°C). Hold at 2.45 volts per cell until current drops to approximately 0.01C amperes. Battery is fully charged under these conditions, and charger should be disconnected or switched to "float" voltage. "Float" or "Stand-by" Service: Hold battery across constant voltage source of 2.25 to 2.30 volts per cell continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Continuous over or undercharging is the single worst enemy of a lead-acid battery. Caution should be exer- cised to insure that the charger is disconnected after cycle charging, or that the float voltage is set correctly. Because there is a chance of off-gassing hydrogen and oxygen if the battery is overcharged, it is important to provide adequate air circulation. Batteries should not be stored in a discharged state (or in a hot place). If a battery has been discharged for some time it may not readily take a charge. To over- come this, leave the charger connected and the battery will eventually begin to accept a charge. Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged after 6 months of storage at 20-25°C, otherwise permanent loss of capacity might occur as a result of sulfation. To prolong shelf life without charging, store batteries at 50°F (10°C) or less. — Sales & Marketing 1HsI% " ISO 9002 3106 Spring Street CERTIFIED Redwood City, CA 94063 USA FM 39170 Tel: 650-364-5001 Fax: 650-366-3662 national-sales@power-sonic.com www.power-sonic.com I-'rinted in the U.S.A. Customer Service I 9163 Siempre Viva Road San Diego, CA 92154 USA Tel: 619-661-2030 Fax: 619-661-3648 battery@power-sonic.com --_-- Apr. 2001 - 2.5M I Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 50 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1' D (12.4Wx 12.4 Hx2.5Dcm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing D SILENT KNIGHT a by Honeywell 0 Ho SD500-AIM SD500-MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL SD500-AIM & SD-500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The 5D500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor Support for Class A (Style 6 & Style 7) or Class B (Style 4) wiring Attractive ivory cover plate with the 5D500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation I I I I I I ri I I I I 1 I I I I I I SD500-AIM & SD500-MIM Addressable Input Modules I Engineering Specifications I The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight I FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate I I To contact being mentioned OL I NI Wiring is Supervised I Power Limited I ) I Toconta being monit ct oredy EOL J - 0 00 00 0 _ 1 I Compatibility lntelliKnight 5820 FACP lntelliKnight 5808 FACP lntelliKnight 5700 FACP Ordering Information SD500-AIM Input Module Addressable input module with Ivory cover plate. SD500-MIM Mini Input Module Addressable mini input module. I I D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350231 Rev.C, 05/06 Copyright © 2006 Silent Knight I I I I 1 I I Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:132 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM, SD500-FRCM-4 Monitor Modules and Model 5D505-ARM Relay Module. Models SD500-ARM, 5D500-AIM, SD500-MIM Addressable Input Modules. Models 5D500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models 5D505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SDSOO-FRCM, -FRCM4, -ARM, -AIM, -MIM: 24 VDC 5D505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0410:145 Li I I I I I I I I I 1 I 0mi A_0 - SD505-ADHR I I I Model 5D5054DHR Duct Detector Housing with Relay Module and Model SD505-DTS Remote Test Switch Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector The SD505-ADHR/DTS addressable duct smoke detector detects smoke and products of combustion present in I air moving through an HVAC duct to prevent re-circulation of smoke into the air handling system. The SD505-ADHR is a heavy duty metal housing with a pre-installed detector base and relay module. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight FACP. The built-in relay module, in I turn, turns off fans, blowers, and other devices. The SD505-DTS is a remote test switch that is used with the SD505-ADHR so you can remote test the Duct Detector. It also provides LED indication of the status of the SD505-ADHR. I The SD505-ADHR/DTS is designed to be used with Silent Knights SD505-APS Photoelectric Smoke Detector and SD505-AIS Ionization Smoke Detector. Models SD505-ADHR and Sampling tube for 2.5' to 5.0' duct width SD505DTS Sampling tube for 5.0' to 10.0' duct width ( / " si-s-io.o Features t \ i --- - ,. ,.. Operating Voltage: 24VACNDC iwo-wire connect-ion to OLL, LED alarm indication and Current @ 24 VDC: communication on sensor head Alarm: Rugged steel backbox with clear Standby: plastic cover SLC Current: Installation template included Standby/Alarm: Large terminal connection screws Alarm Relay: Interchangeable "plug-in" photoelectric or ionization heads UL listed Trouble Relay: Operates on 24 VACNDC or Air Velocity: 120/240 VAC 5004000 fpm Specifications 300-4000 fpm Included Parts: Sensitivity: Metal housing with 7.5" exhaust tube 1.1 5D5054AB detector base 0.8 Installation template Humidity: 4 mounting screws Ambient Temperature: Parts not included with SD505-ADHR/DTS: SD505-ADHR Photoelectric Smoke Det. 50505-APS Dimensions: Ionization Smoke Det. 5D505-AIS Sampling tube for 6" to 2.5' duct width STS-2.5 120/240 VAC 75 mA Max. 35 mA Max. .082 mA 1OA@ 24VDC 10 A@ 120/240 VAC 2.5A@ 30VDC 5D505-APS 5D505-AIS 5D505-APS 5D505-AIS 10 to 85% RH 32°F to 100°F (0°C to 37°C) SD505-DTS SD505-DTS Dimensions: 4.5" H x 2.75" W x 1-5/8" 0 Color: SD505-ADHR: Gray SD505-DTS: Red 2.25" 0 10"Hx8.25"Wx DSILENT KNIGHT Model 5D505-ADHR Duct Detector Housing with Relay Module , T and Model 5D505.DTS Remote Test Switch Engineering Specifications The air duct smoke detector with relay module remote test switch shall be Silent Knight module SD505-ADHR/DTS. The housing shall contain a detector base, Silent Knight model SD505-4AB. The detector base and housing shall be compatible with Silent Knight smoke detectors models SD505-APS and SD505-AIS. Alarm Relay rated at IOA@ 120/240 VAC and 24 VDC to control HVAC power. Module shall have separate LEDs that indicate normal or alarm condition. Module shall have a momentary key switch for testing of the duct detector. Class A (St)le 6) Wiring SD505-ADHR and 5D505-DTS Wiring Connections Class B (Style 4) Wiring D SILENT KNIGHT 0 7550 Meridian Circle, Maple Grove, MN 553694927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350236, Rev. 11/01 FAX: 763493-6475 World Wide Web: http://www.silentknight.com Copyright © 2001 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0559:139 Page 1 of 1 CATEGORY: Duct smoke Detector Housing/Base LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD505-ADHR duct smoke detector housing with relay and SD-505-DTS detector test station. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, and UL label. APPROVAL: Listed as a duct smoke detector housing/base and test station for use only with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog I Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6" Base) 5D505-4AB (4" Base) D SILENT KNIGHT by Honeywell Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications I The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight 5D505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. I Diameter = 5-15/16" I Diameter = 3-15/16" 0 / 0) Height = 2 inches, Including base D1Q1Qff Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:129 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model SD505-APS analog addressable photoelectric type smoke detector with model 5D505- 4AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:149 I I a I I 1 I I *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager I I 111 III I I I I I 1 I