Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; FS080012; Permit11/3/21, 1:22 PM FS080012 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS080012 Job Address: 2200 FARADAY AV Permit Type: FIXSYS Parcel No: 2121204100 Lot #: 0 Status: ISSUED Applied 6/11/2008 Approved: 6/11/2008 Reference No.: Issued: 6/11/2008 PC #: Inspector: Project Title: CATALINA RESTAURANT HOOD & DUCT PLAN CHECK & INSPECTIONS Applicant: Owner: CHRISTOPHERSON FIRE PROTECTION D L FARADAY L P C/O DRA ADVISORS LLC P.O. BOX 2302 220 E 42ND ST #27 CHINO, CA NEW YORK NY 909-591-0438 Fees ($) Add'I Fees ($) Total ($) Balance 130 0 130 0 1/1 FSoSoot~- This manual Is Intended for use with ANSUL® R-102 Restaurant Fire Suppression Systems. Those who Install, operate, recharge, or maintain these fire sup- pression systems should read this entire manual. Specific sec- tions will be of particular Interest depending upon one's responsibilities. Design, Installation, recharge, and maintenance of the system must conform to the limitations detailed In this manual and per- formed by an Individual who attended an ANSUL training pro- gram and became trained to Install, recharge, design, and main- tain the Ansul system. Fire suppression systems are mechanical devices. They need periodic care. Maintenance Is a vital step in the performance of your fire suppression system. As such It must be performed in accordance with NFPA 96 (Standard for the Installation of Equipment for the Removal of Smoke and Grease-Laden Vapors from Commercial Cooking Equipment) and NFPA 17A (Standard on Wet Chemical Extinguishing Systems) by an authorized ANSUL distributor. To provide maximum assurance that the fire suppression system will operate effectively and safely, mainte- nance must be conducted at six-month intervals, or earlier if the situation dictates. Twelve-year maintenance must include agent tank hydrostatic testing. ANSUL PART NO. 4180877010 ANSUL, ANSUL. AUTOMAN and ANSULEX are trademarks of Ansul incorporated or its affiliates. SECTION I - GENERAL INFORMATION UL EX. 3470 ULCCEx747 Page 1-1 4-1-06 REV. 4 DESIGN AND APPLICATION The ANSUL R-102 Restaurant Fire Suppression System is designed to provide fire protection for restaurant cooking appli- ances, hoods, and ducts. It is a pre-engineered group of mechan- ical and electrical components for installation by an authorized ANSUL distributor. The basic system consists of an ANSUL AUTOMAN regulated release assembly which includes a regulat- ed release mechanism and a liquid agent storage tank housed within a single enclosure. Nozzles, detectors, cartridges, liquid agent, fusible links, pulley tees, and pulley elbows are supplied in separate packages in the quantities needed for each fire suppres- sion system arrangement. The system provides automatic actuation; or it can be actuated manually through a remote manual pull station. The system is also capable of shutting down appliances at system actuation. For appliance shutdown requirements, refer to the current version of NFPA 17A, "Standard For Wet Chemical Extinguishing Systems," and NFPA 96, "Standard For Ventilation Control and Fire Protection of Commercial Cooking Operations." Additional equipment includes: remote manual pull station, mechanical and electrical gas valves, pressure switches, and elec- trical switches for automatic equipment and gas line shut-off. Accessories can be added, such as alarms, warning lights, etc., to installations where required. The R-102 system suppresses fire by spraying the plenum area, the filters, cooking surfaces, and the exhaust duct system with a predetermined flow rate of ANSULEX Low pH Liquid Fire Suppressant. When the liquid agent is discharged onto a cooking appliance fire, it cools the grease surface, and reacts with the hot grease (saponification) forming a layer of soap-like foam on the surface of the fat. This layer acts as insulation between the hot grease and the atmosphere, thus helping to prevent the escape of combustible vapors. Exhaust fans in the ventilating system should be left on. The forced draft of these fans assists the movement of the liquid agent through the ventilating system, thus aiding in the fire suppression process. These fans also provide a cooling effect in the plenum and duct after the fire suppression system has been discharged. The system is UL listed with or without fan operation. Make up or supply air fans, integral to the exhaust hood(s) being protected, shall be shut down upon system actuation. Along with the fire suppression system, the total system design must include hand portable fire extinguisher(s) located within the cooking/restaurant area that can be used to manually suppress a fire that may be burning in an unprotected area. Refer to NFPA 10, "Standard For Portable Fire Extinguisher," for additional information. UL LISTING The R-102 Restaurant Fire Suppression System has been tested and is listed by Underwriters Laboratories, Inc. as a pre-engi- neered system. The system is in compliance with UL Test Standard 300. These tests require extinguishment of fires which are initiated in deep fat fryers, ranges, griddles, char-broilers, woks, upright broilers, chain-broilers, filters, plenum chambers, hoods, and ducts after pre-loading each appliance with a pre- scribed amount of cooking grease. Each fire is allowed to progress to maximum intensity before the fire suppression system is actuated. DEFINITION OF TERMS Actuation Gas Line: Piping from the ANSUL AUTOMAN Regulated Release Assembly which supplies nitrogen or carbon dioxide to the Regulated Actuator Assembly for multiple-tank sys- tem actuation. Agent Tank: A pressure vessel containing the liquid agent. ANSUL AUTOMAN Regulated Release Assembly (Electrical): An assembly which contains the regulated release mechanism, agent tank (ordered separately), expellant gas hose, solenoid, and electric switch within a metal enclosure. The enclosure contains knockouts to facilitate component hookups. ANSUL AUTOMAN Regulated Release Assembly (Mechani- cal): An assembly which contains the regulated release mecha-nism, agent tank (ordered separately), and expellant gas hose within a metal enclosure. The enclosure contains knockouts to facilitate component hookups. Authority Having Jurisdiction: The "authority having jurisdiction" is the organization, office, or individual responsible for "approving" equipment, an installation, or a procedure. The phrase "Authority Having Jurisdiction" is used in a broad manner since jurisdictions and "approval" agencies vary as do their responsibilities. Where public safety is primary, the "authority having jurisdiction" may be a federal, state, local, or other regional department or individual such as a fire chief, fire marshal, chief of a fire prevention bureau, labor department, health department, building official, electrical inspector, or others having statutory authority. For insurance pur- poses, an insurance company representative may be the "author- ity having jurisdiction." In many circumstances the property owner or his designated agent assumes the role of the "authority having jurisdiction;" at government installations, the commanding officer or departmental official may be the "authority having jurisdiction." Blow-Off Cap: A cap which covers the end of the nozzle tip and prevents grease from plugging the nozzle orifice. Branch Line: The agent distribution piping which extends from the supply line to the nozzle(s). Bursting Disc: A disc installed in the tank adaptor which elimi- nates the siphoning of the agent up the pipe during extreme tem- perature variations. Cartridge: A sealed, steel pressure vessel containing nitrogen or carbon dioxide gas used to pressurize the agent tank. Cooking Appliance: Includes fryers, griddles, ranges, upright broilers, chain broilers, natural charcoal broilers, or char-broilers (electric, lava rock, gas-radiant, or mesquite). Cooking Area: Cooking area is defined as the maximum surface that requires protection. Each type of appliance has a defined cooking area. For example, the maximum cooking area is the fry- pot for a fryer without a dripboard and the maximum cooking area is the combined frypot and dripboard for a fryer with a dripboard. Conduit Offset Assembly: A pre-formed piece of conduit which can be installed between the ANSUL regulated release and the conduit to allow the wire rope for the detection, gas valve and remote manual pull station to be installed in a more convenient manner. Depth: When referring to depth as a linear dimension, it is the horizontal dimension measured from front to back of the appliance or plenum. SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its appropri- ate manual. Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Lane Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any Installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical Including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the size of duct being protected. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 4-1-06 REV.6 GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2-8 IN. (5 - 20 cm) FIGURE 1 000173 In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assem- bly that will not interfere with the damper. Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER! 16 IN. (41 cm) DIAMETER One 1W nozzle (Part No. 419336) = one flow number 50 in. (127 cm) perimeter maximum 16 In. (41 cm) diameter maximum DUCT SIZES UP TO 100 IN. (254 cm) PERIMETER/ 32 IN. (81.3 cm) DIAMETER One 2W Nozzle (Part No. 419337) = two flow numbers 100 in. (254 cm) perimeter maximum 32 in. (81.3 cm) diameter maximum A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi- mum diameter of 24 in. (61 cm) of coverage. The chart below shows the maximum protection available from each duct nozzle. Part 3.0 Gallon 1.5 Gallon Description No. System System 2W Nozzle 419337 Maximum Maximum l0o in. (254cm) l0o in. (254cm) Perimeter Perimeter 1W Nozzle 419336 Maximum Maximum 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter FIGURE 6 000197 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4-1-06 REV.4 Plenum Protection The R-102 system uses the 1W Nozzle (Part No. 419336) or the 1 Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the 1 N nozzle tip is stamped with 1 N, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The plenum width must . not exceed 4 ft. (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. b. When protecting plenums with the 1W nozzle, two options of cov- erage are available: j. Option 1: The 1W nozzle must be on the center line of the single or "V" bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See Figure 7. Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the filter. See Figure 8. 201) 20 cm) UM NOZZLE TIP MUST BE w THIS AREA FIGURE 8 000200 HORIZONTAL PROTECTION - OPTION 1 1 N NOZZLE - PART NO. 419335 — SINGLE BANK PROTECTION One IN nozzle will protect 10 linear feet (3.1 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the L nozzle. See Figure 9. 2-4 IN. 10 Fr. (3.1 m) 10 cm) MAXIMUM je 000201 000202 FIGURE 9 20 IN. (51 con) MAXIMUM 1 IN. (2.5 cm) MINIMUM 201N.(51 Cm) MAXIMUM I IN. (2.5 cm) MINIMUM FIGURE 7 990199 RIGHT-TO-LEFT cI_— 000008 0000 CENTERLINE .- FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-9 4-1-06 REV. 8 \.. ' Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in. x 19 in. 19.5 in. x 253/8 in. 290 13 in. to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 3N See Figure See Figure 18 (50 cm x 48 cm) (50 cm x 65 cm) 18 18 in. x18in. l8 in. x273/4in. 3N 25 in. to35in. See Figure 19 (46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND ± 1 . IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 17 002288 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA FIGURE 18 002287 - Range Protection 1-Flow Nozzle The R-102 system uses five different nozzles for the protection of ranges. Two of the design options require a one-flow nozzle and three of the design options require two-flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. When protecting hot top ranges, the entire cooking surface must be protected. Range Protection (1-Flow Nozzle) Single and multiple burner ranges can be protected using a IN nozzle, Part No. 419335. The nozzle tip is stamped with IN, indi- cating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm) per nozzle. When protecting a range, the 1 N nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figure 26. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULCCEx747 Page 4-13 4-1-06 REV. 6 When this type of hazard is equipped with a back shelf located above the range top, two protection options are available: One requires a IF nozzle, Part No. 419333, and the other option requires a 260 nozzle, Part No. 419341. Option 1: 1 F Nozzle: When using the 1 F nozzle for range protec- tion with or without back shelf, the maximum length of the burner grates being protected must not exceed 28 in. (71 cm) and the maximum area of the burner grates must not exceed 336 sq. in. (2168 sq. cm). See Figure 27 for nozzle location details. IF NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 =) Aim Il (51 cm) 40-481N. f II MINIMUM I II 20 IN. (102-122 CM) 1211 14 IN. MAXIMUM MAXIMUM FRONT TO REAR MAXIMUM CENTERLINE IF NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 27 Option 2: 260 Nozzle: When using the 260 nozzle for range pro- tection with or without back shelf, the maximum length of burner grates being protected must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. Cm). Nozzle must be located on the front edge of the burn- er grates and aimed at a point 10 in. (25 Cm) from the back edge of the burner grates. Nozzle must be mount- ed 30 to 40 in. (76 to 102 cm) above the hazard sur- face. See Figure 28. 260 NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 cm) rt 10 IN. (25 cm) MAXIMUM IN NOZZLE 32 IN. (81 cm) MAXIMUM 30-4OIN. (76-102cm) 18 IN. (45.7 cm) MINIMUM AIMING POINT 10 IN. / (25 cm) MAXIMUM 10 IN. (25 cm) FROM BACK OF BURNER GRATES FIGURE 28 FIGURE 26 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV.5 10-1-02. Range Protection 2-Flow Nozzle High Proximity Application (2-Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this Is a two-flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 sq. in. (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 29 and 30. 01 245 NOZZLE TIP LOCATION CENTER 0 COOKING SURFACE OR 113/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZ TO CENTER OF ANY BURNER GRATE ING 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 501. (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 40 IN. (102 cm) MINIMUM HEIGHT OF 245 NOZZLE TIP 245 NOZZLE TIP LOCATION CENTER OF ) COOKING SURFACE OR 113/B IN. (29cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE COOKING AREA COOKING AREA 000766 FIGURE 30 000238 FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULCCEx747 Page 4-19 10-1-02 REV. 3 2-Flow Griddle Protection (Continued) Option 2— Nozzle Perimeter Located High Proximity Application: 30 in. to 50 in. (76 cm to 127 cm) above the cooking surface. This high proximity application uses the 260 nozzle, Part No. 419341. The nozzle tip is stamped with 260 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 260 nozzle will protect a maximum cooking area of 1440 sq. In. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to 2 In. (5.1 cm) inside perimeter, and aimed at the center of the cooking surface. See Figure 39 and 40. I NOZZLE LOCATION II 0-2 IN. (0-5Cm) I I INSIDE PERIMETER I 50 IN. OF COOKING SURFACE I (127 cm) I MAXIMUM HEIGHT OF 260 NOZZLETIP Al CM) / / I MINIMUM I 1/ HEIGHT EDGE I 1/ I 0F260 OF i // , NOZZLETIP COOKING I I SURFACE I Jfr' 000243 COOKING AREA [ r MIDPOINT OF COOKING SURFACE I -V j_cOLNG AIM POINT AREA L ----- 260 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0-5 cm) OF COOKING SURFACE EDGE NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. I. FIGURE 40 000241 FIGURE 39 000243 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-21 10-1-02 REV. 3 2-Flow Griddle Protection (Continued) Option 2— Nozzle Perimeter Located (Continued) Low Proximity Application: 10 In. to 20 In. (25 cm to 51 cm) above the cooking surface. . The low proximity application uses the 2120 nozzle, Part No. 419343. 1' The nozzle tip Is stamped with 2120 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 2120 nozzle will protect a maximum cooking area of 1440 sq. In. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in. (5.1 cm) inside perime- ter, and aimed at the center of the cooking surface. See Figure 43 and 44. I NOZZLE LOCA11ON I O-2 IN. (O-5cm) I INSIDE PERIMETER I 201N. - L.— OF COOKING SURFACE i (51cm) MAXIMUM HEIGHT I 0F2120 NOZZLE TIP " I 1O IN. (25CM) I I / I MINIMUM I HEIGHT I I ii 0F2120 I NOZZLE TIP I i. I EDGE OF COOKING SURFACE p. FIGURE 43 000243 - .. COOKING AREA -1 CENTER OF I COOKING SURFACE - I Y I p COOKING AREA: l— AIM POINT A I I 2120 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE _ - . • -. WITHIN O-2 IN. (0-5 cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT CENTER OF COOKING SURFACE. FIGURE 44 000241 Upright/Salamander Broiler Protection The R-1 02 system uses two 1/2N Nozzles (Part No. 419334) for all upright/salamander broiler protection. The nozzle tip is stamped 1/2N, indicating that this is a half-flow nozzle. A pair of these noz- zles will equal one flow number. Two 1/2N nozzles will protect a maximum hazard area (internal broiler chamber) of 30 in. x 32.5 in. (76 cm x 82.5 cm). These noz- zles must always be used in pairs on an upright/salamander broil- er. One nozzle must be positioned above the grate and pointed at the back opposite corner of the broiler chamber. The second noz- zle must be pointed down into the center of the drip pan through the open slot. See Figure 50. Note: If metal blow-off caps are required for upright broiler or sala- mander broiler protection, use (2) two IN nozzles, Part No. 419335, instead of 1/2N nozzles. SALAMANDER BROILER 000251 BROILER CHAMBER SIDE VIEW 000252 FIGURE 50 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-23 4-1-06 REV.7 - - Overhead Chain Broiler Protection (Continued) Example No. 1 - Internal broiler size is 24 in. long x 20 in. wide (61 x 51 cm), with an opening of 16 in. x 16 in. (40.6 x 40.6 cm). To determine minimum opening size, multiply the internal length and the internal width by 0.6: Length of opening -24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Width of opening -20 in. x 0.6 = 12.0 in. (51 cm x 0.6 = 30.5 cm) The minimum allowable opening for overhead protec- tion would be 14.4 in. x 12.0 in. (36.6 x 30.5 cm). This example would be acceptable for overhead pro- tection. Example No. 2 - Internal broiler size is 30 in. long x 24 in. wide (76 x 61 cm) with an opening of 22 in. x 12 in. (56 x 30 cm). To determine minimum opening size, multiply internal length and internal width by 0.6: Length of opening -30 in. x 0.6 = 18.0 in. (76 cm x 0.6 = 45.7 cm) Width of opening -24 in. x 0.6 = 14.4 in. (61 cmx0.6=36.6cm) Minimum allowable opening for overhead protection would be 18 in. x 14.4 in. (45.7 x 36.6 cm). Because this broiler has an opening of 22 in. x 12 in., the 12 in. width is below the minimum allowable cal- culated dimension of 14.4 in. (36.6 cm) and therefore would not be acceptable for overhead protection. Upright/Salamander Broiler Protection UPRIGHT BROILER The R-102 Restaurant Fire Suppression System uses one IN Nozzle, Part No. 419335, for upright/salamander broiler protection. The nozzle tip is stamped with 1 N, indicating that this is a one-flow nozzle. One IN nozzle will protect a maximum hazard area (internal broil- er chamber) of 16 in. (41 cm) deep x 29 in. (74 cm) wide. The single IN nozzle must be located directly in line with either vertical edge of the broiler opening, 6 in. (15 cm) to 12 in. (30 cm) in front of the broiler, and 0 in. to 12 in. (30 cm) above the top of the broiler. The nozzle must be aimed at the center of the broiler opening. See Figure 49. VERTICAL EDGE OF BROILER OPENING AIM AT CENTER OF BROILER OPENING FIGURE 49 007128 AT CENTER OF BROILER OPENING IN NOZZLE (PART NO. 419335) 12 IN NOZZLE 4- LOCATION ZONE (30 crn) 6 IN. (15 cm) 6 IN. (15 cm) SECTION IV -SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV.6 4-1-06 Gas-Radiant/Electric Char-Broiler Protection The A-i 02 system uses the IN nozzle, (Part No. 419335) for gas- radiant/electric char-broiler protection. The nozzle tip on the 1 nozzle is stamped with a IN, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip mustbe located 15 to 40 In. (38 to 102 cm) above the hazard surface. When using this nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 51. COOKING AREA COOKING AREA COOKING AGEA 40 IN. (102 an) MAXIMUM MINIMUM 000257 - •-- FIGURE 51 • LINE MUST NOT 3 BRANCH LINES EXCEED 24 FT. (7.3 m) 2W NOZZLE ) IN NOZZLE p-w IN NOZZLE SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-49 4-1-06 REV. 4 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements —3.0 Gallon System The maximum length between the start of the first branch line and the start of the last branch line must not exceed 24 ft. (7.3 m). When the supply line Is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. (7.3 m). See Figure 93. . The total length of all branch lines must not exceed 36 ft. (10.9 m). See Figure 93. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. A maximum of two nozzles are allowed per duct branch line. The requirements of the following table must not be exceeded: [fj 23O NOZZLE (/ / 245 NOZZLE 1/2N NOZZLE (BRANCH LINE IN BOLD) - COMBINED LENGTH MUST 000502 NOT EXCEED 36 FT. (10.9 m) FIGURE 93 Duct Plenum Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft. 12 ft. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. , 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 900 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11* 4 2 4 Numbers Twelve (12) flow numbers are allowed In any one tank for duct and plenum protection only. Twelve (12) flow numbers are allowed with any one tank using only two-flow appliance nozzles. S. Twelve (12) flow numbers are allowed with any one tank using only three-flow appliance nozzles. Special Instructions: Twelve (12) flow numbers are allowed when four (4) Dean Industries GTI Gas Fryers are protected at low proximity as shown in Figure 58 on Page 4-32. The discharge piping must beas shown ln Figure 590n Page 4-32. For certain McDonalds applIcations. 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 1/2N electrostatic precipitator nozzle, one (1)1 N plenum nozzle, and four (4) two-flow appliance nozzles. Contact Ansul Applications Engineering Department for additional Information. Detector Placement Requirements EXHAUST DUCTS Each exhaust duct must have at least one detector installed in the duct entrance, located in the airstream of the cooking vapors, or at a maximum of 20 ft. (6.1 m) into the duct opening. See Figure 98. FIGURE 98 000271 NOTICE When gas appliances are used and the flue gases from the burner are exhausted into the duct, the detector must be kept out of the air stream of these exhaust gases. These gases can be very hot and could actuate the system unnecessarily. Duct openings that are long and narrow or large enough to require multiple duct nozzles may require additional detectors. ELECTROSTATIC PRECIPITATOR If an electrostatic precipitator is located at or near the base of the exhaust duct, it is necessary to locate a detector below the pre- cipitator, at the base of the duct, and also locate one in the duct, just above the precipitator. See Figure 99. When, Installing the detector bracket and system conduit, make certain they do not interfere with the operation of the precipitator. 'Note: On secondary filtration units utilizing multiple filter stages/media, contact Ansul Technical Services for instructions. 16. FIGURE 99 000268 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-53 4-1-06 REV.3 DETECTION SYSTEM REQUIREMENTS Once the fire suppression system design has been determined, a detection system design must be completed. This section contains guidelines and limitations for detection system installation. Detector Identification The two types of detectors are distinguished from each other by their location in the detection system. The Terminal Detector (Part No. 56838, 15375, or 417368) is the last in a series of detectors, or the only detector used in a single-detector system. This detector is thus named because it is at the point at which the wire rope ends, or "terminates." A Series Detector (Part No. 56837, 15373, or 417369) is any detector located in-line between the regulated release mech- anism and the terminal detector. Detector/Pulley Elbow Quantity The quantity of detectors used in the system will vary depending on the style of detector used. Conduit runs, pulley elbows, and number of detectors per sys- tem must be within the approved system guidelines. The fol- lowing requirements must not be exceeded: Maximum Maximum Maximum Number of Number of Length of 1/2 Detectors Elbows in. Conduit per System per System per System Clip on Style 12 18 125 ft. (38.1 m) Detector Hinge Style 5 8 103 ft. (31.3 m) Detector Scissors Style 15 20 150 ft. (45.7 m) Detector If hinge style detectors are mixed in a system with either clip- on or scissor style, 4 series and 1 terminal is the maximum number allowed. If clip-on style are mixed with scissor style, the maximum allowed Is 11 series and 1 terminal. NOTICE When using the "clip-on" style detector, the ter- minal detector may use the "hinged" style mounting bracket with the "clip-on" style linkage. This Is only allowed with the terminal detector. No other linkages are allowed to be mixed with other brackets. When using this option, the total number of "clip-on" style detectors (11 series and 1 terminal) is still allowed. If hinge style detectors are mixed in a system with either clip- on or scissor style, the maximum length of wire rope must not exceed 103 ft. (31.4 m) and the maximum number of pulley elbows must not exceed 8. If clip-on style are mixed with scis- sor style, the maximum length of wire rope must not exceed 125 ft. (3.81 m) and the maximum number of pulley elbows must not exceed 18. 4. If the hazard requires more than 15 detectors, up to five 101 Remote Releases (Part No. 32381) can be used for system actuation. Each 101 remote release allows the use of a maxi- mum of 15 "scissor" style detectors (14 series and 1 terminal) for a total of 75 detectors if needed. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-54 REV.3 4-1-06 j Detector Replacement Requirements (Continued) COOKING APPLIANCES If the cooking appliance is located under an exhaust duct where a detector has been mounted, it is normally not necessary to utilize another detector for that cooking appliance, provided the detector ' is not more than 12 in. (30 cm) into the duct. See Figure 100. APPLIANCE APPLIANCE APPLIANCE APPLIANCE REQUIRES COVERED BY COVERED BY REQUIRES SEPARATE DETECTOR DETECTOR SEPARATE DETECTOR UNDER DUCT UNDER DUCT DETECTOR FIGURE 100 000269 Each cooking appliance with a continuous cooking surface not exceeding 48 In. x 48 in. (122 x 122 cm) can be protected by a min- imum of one detector. Cooking appliances with a continuous cook-ing surface exceeding 48 in. x 48 in. can be protected by at least one detector per 48 In. x 48 In. cooking area. Detectors used for cooking appliances must be located above the protected appli- ance toward the exhaust duct side of the appliance. The detector should be located in the air stream of the appliance to enhance system response time. Note: For overlapping detector coverage, see Page 4-42 for design requirements. Detection Une Requirements CONDUIT Rigid conduit or 1/2 Inch EMT thin-wall conduit. may be used. Standard steel conduit fittings (compression type are recommend- ed) must be employed to properly Install the detection system. All conduit or pipe must be firmly supported. When using pipe, make certain that all ends are carefully reamed, deburred and blown clear of chips and scale before assembly. NOTICE The conduit offset can be used at the top or bot- tom of the regulated release to change direction - of the conduit. The conduit offset cannot be used with pulley tees. All other changes in direc- tion must be made by using ANSUL approved pulley elbows, Part No. 423254 or 415670. See Figure 101. FIGURE 101 000270 Fusible Link Selection When 'possible, temperature readings should be taken at each detector làcation to determine correct fusible link temperature rat- ing. Temperature can be recorded using either a maximum regis- tering thermometer, Part No. 15240, temperature tape or any other accurate thermometer. 9e; A8i26L. TEMPERATURE RATING STAMPED ON FUSIBLE LINK BODY 0 _ OD0170 000171 K S M L STYLE (260 C) ONLY FIGURE 102 Select correct UL Usted fusible link(s) for installation in detector(s) according to the temperature condition. Two styles are available. See Figure 102. See Component Section for detailed temperature ratings. SECTION V - INSTALLATION INSTRUCTIONS UL EX. 3470 ULC CEx747 Page 5-4 REV.4 10-1-02 INSTALLING THE ACTUATION AND EXPELLANT GAS LINE (Continued) Actuation Gas Line (Continued) Run piping up through the regulated release assembly enclo- sure knockout to the inlet on top of each regulated actuator assembly used within the system. The total combined length of the actuation gas line from the regulated release assembly to all regulated actuator assem- blies must not exceed 20 ft. (6 m) when using an LT-20-R nitro- 10. cartridge, an LT-30-R nitrogen cartridge, a 101-10 CO2 cartridge, or a 101-20 CO2 cartridge. See Figure 8. If an expellant gas line is connected to the regulated release assembly along with an actuation gas line, the total combined length of the actuation and expellant gas line must not exceed 30 ft. (9 m). See Figure 9. A combined total of nine fittings may be used in these lines, eight 900 elbows and one tee. Two 450 elbows equal one 900 elbow. ACTUATION GAS LINE WITH AN LT-20-R, LT-30-R, 101-20 OR 101-30 CARTRIDGE MAXIMUM LENGTH -20 Ft (6 m). -.. MAXIMUM NO. OF FITTINGS -9 REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED ACTUATOR ASSEMBLY REGULATED ACTUATOR ASSEMBLY ANSULAUTOMAN FIGURE 8 REGULATED RELEASE ASSEMBLY 000775 ACTUATION AND EXPELLANT GAS LINES WITH A DOUBLE-TANK OR 101-30 CARTRIDGE MAXIMUM COMBINED LENGTH -30 Ft (9 m), MAXIMUM COMBINED FITTINGS -9 ASSEMBLY ACTUATOR SSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN COMBINED TOTALS REGULATED ACTUATOR ASSEMBLY REGULATED ACTUATOR ASSEMBLY REGULATED RELEASE ASSEMBLY FIGURE 9 ANSUL AUTOMAN REGULATED 298 RELEASE ASSEMBLY