Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; AS090006; Permit11/3/21, 12:37 PM AS090006 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2200 FARADAY AV Permit Type: SPRINK Parcel No: 2121204100 Lot #: 0 Permit No: AS090006 Status: ISSUED Applied 1/16/2009 Approved: 1/16/2009 Reference No.: Issued: 1/16/2009 PC #: Inspector: Project Title: SIERRA WIRELESS FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: PARAMOUNT FIRE SYSTEMS, INC P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: D L FARADAY L P C/a DRA ADVISORS LLC 220 E 42ND ST #27 NEW YORK NY Fees ($) Add'I Fees ($) Total ($) Balance 130 0 130 0 1/1 ASOI000(a PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 92072 C16-788204 HYDRAULIC CALCULATIONS FOR SIERRA WIRELESS 2200 FARADAY CARLSBAD, CALIFORNIA 1ST FLOOR DATE: JAN 18, 2009 REMOTE AREA "A" 1ST FLOOR CONVERSION TO LIGHT HAZARD SPACE -DESIGN DATA- OCCUPANCY CLASSIFICATION: Light Hazard DENSITY: .10 gpm per sq. ft. AREA OF APPLICATION: 1851 sq. ft. COVERAGE PER SPRINKLER: Varies NUMBER OF SPRINKLERS CALCULATED: 5 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 204.2 gpm TOTAL WATER REQUIRED (including hose): 304.2 gpm FLOW & PRESSURE (at base of riser) 204.2 gpm @ 46.8 psi (at node BOR) SPRINKLER ORIFICE SIZE: 17/32" K= 8.00 NAME OF CONTRACTOR: PARAMOUNT FIRE SYSTEMS, INC. DESIGN/LAYOUT BY: TT AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE MARSHAL SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ!D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) FLOWTEST 110.0 100.0 1546.0 109.5 304.2 48.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 304.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 204.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A 16.5 - - - - 39.6 - - - B 16.5 - - - - 39.4 - - - 1 16.5 - - - - 39.6 - - - 2 12.0 K= 6.50 37.9 40.0 3 12.0 K= 6.54 37.8 40.2 4 12.0 K= 6.50 38.0 40.1 5 16.5 - - - - 39.4 - - - 6 16.5 - - - - 39.6 - - - 7 12.0 K= 6.71 39.6 42.2 8 12.0 K= 6.63 39.6 41.7 9 16.5 - - - - 39.4 - - - 10 16.5 - - - - 39.6 - - - 11 16.5 - - - - 39.4 - - - 12 16.5 - - - - 39.6 - - - 13 16.5 - - - - 39.4 - - - 14 16.5 - - - - 39.6 FLOWTEST -4.0 SOURCE 48.8 204.2 16 16.5 - - - - 39.6 - - - 17 16.5 - - - - 39.5 - - - 18 16.5 - - - - 39.6 - - - 19 16.5 - - - - 39.5 - - - 20 16.5 - - - - 39.6 - - - 21 16.5 - - - - 39.5 - - - TOR 16.5 - - - - 39.8 - - - BOR 0.5 - - - - 46.8 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT), SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 8.2 2.067 PL 192.46 PP 0.2 A 16.5 0.0 39.6 0.0 0.8 120 FTG 4T PE 0.0 B 16.5 0.0 39.4 0.0 0.001 TL 232.46 PV Pipe: 2 8.2 6.065 PL 10.00 PP 0.0 1 16.5 0.0 39.6 0.0 0.1 120 FTG ---- FE 0.0 A 16.5 0.0 39.6 0.0 0.000 TL 10.00 PV Pipe: 3 -8.2 4.026 PL 10.00 PP 0.0 5 16.5 0.0 39.4 0.0 0.2 120 FTG ---- PE 0.0 B 16.5 0.0 39.4 0.0 0.000 TL 10.00 PV Pipe: 4 53.3 2.067 PL 105.46 PP 3.7 1 16.5 0.0 39.6 0.0 5.1 120 FTG 2T PE 1.9 2 12.0 6.5 37.9 40.0 0.029 TL 125.46 PV Pipe: 5 13.3 2.067 PL 14.00 PP 0.0 2 12.0 6.5 37.9 40.0 1.3 120 FTG ---- PE 0.0 3 12.0 6.5 37.8 40.2 0.002 TL 14.00 PV Pipe: 6 -26.9 2.067 PL 18.00 PP 0.1 3 12.0 6.5 37.8 40.2 2.6 120 FTG ---- FE 0.0 4 12.0 6.5 38.0 40.1 0.008 TL 18.00 PV Pipe: 7 -66.9 2.067 PL 54.96 PP 3.4 4 12.0 6.5 38.0 40.1 6.4 120 FTG 2T FE -1.9 5 16.5 0.0 39.4 0.0 0.045 TL 74.96 PV Pipe: 8 61.6 6.065 PL 10.00 PP 0.0 6 16.5 0.0 39.6 0.0 0.7 120 FTG ---- PE 0.0 1 16.5 0.0 39.6 0.0 0.000 TL 10.00 PV Pipe: 9 8.0 2.067 PL 192.46 PP 0.2 6 16.5 0.0 39.6 0.0 0.8 120 FTG 4T PE 0.0 9 16.5 0.0 39.4 0.0 0.001 TL 232.46 PV Pipe: 10 58.7 4.026 PL 10.00 PF 0.0 9 16.5 0.0 39.4 0.0 1.5 120 FTG ---- PE 0.0 5 16.5 0.0 39.4 0.0 0.001 TL 10.00 PV Pipe: 11 69.6 6.065 PL 10.00 PF 0.0 10 16.5 0.0 39.6 0.0 0.8 120 FTG ---- PE 0.0 6 16.5 0.0 39.6 0.0 0.000 TL 10.00 PV - Pipe: 12 7.8 2.067 FL 192.46 PP 0.2 10 16.5 0.0 39.6 0.0 0.7 120 FTG 4T PE 0.0 11 16.5 0.0 39.4 0.0 0.001 TL 232.46 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 50.7 4.026 PL 10.00 PF 0.0 11 16.5 0.0 39.4 0.0 1.3 120 FTG ---- PE 0.0 9 16.5 0.0 39.4 0.0 0.001 TL 10.00 PV Pipe: 14 77.4 6.065 PL 12.00 PH 0.0 12 16.5 0.0 39.6 0.0 0.9 120 FTG ---- PE 0.0 10 16.5 0.0 39.6 0.0 0.000 TL 12.00 PV Pipe: 15 36.0 2.067 PL 120.96 PH 2.0 12 16.5 0.0 39.6 0.0 3.4 120 FTG 2T PE 1.9 7 12.0 6.7 39.6 42.2 0.014 TL 140.96 PV Pipe: 16 -6.2 2.067 PL 18.00 PH 0.0 7 12.0 6.7 39.6 42.2 0.6 120 FTG ---- PE 0.0 8 12.0 6.6 39.6 41.7 0.001 TL 18.00 PV Pipe: 17 -47.9 2.067 PL 54.96 PH 1.8 8 12.0 6.6 39.6 41.7 4.6 120 FTC 2T PE -1.9 13 16.5 0.0 39.4 0.0 0.024 TL 74.96 PV Pipe: 18 42.9 4.026 PL 12.00 PF 0.0 13 16.5 0.0 39.4 0.0 1.1 120 FTG ---- PH 0.0 11 16.5 0.0 39.4 0.0 0.001 TL 12.00 PV Pipe: 19 113.5 6.065 PL 9.71 PH 0.0 14 16.5 0.0 39.6 0.0 1.3 120 FTG T PE 0.0 12 16.5 0.0 39.6 0.0 0.001 TL 39.71 PV Pipe: 20 -90.7 6.065 PL 2.29 PH 0.0 16 16.5 0.0 39.6 0.0 1.0 120 FTG T PE 0.0 14 16.5 0.0 39.6 0.0 0.000 TL 32.29 PV Pipe: 21 7.2 2.067 PL 192.46 PH 0.2 16 16.5 0.0 39.6 0.0 0.7 120 FTC 4T PE 0.0 17 16.5 0.0 39.5 0.0 0.001 TL 232.46 PV Pipe: 22 90.7 4.026 PL 12.00 PF 0.0 17 16.5 0.0 39.5 0.0 2.3 120 FTG ---- PE 0.0 13 16.5 0.0 39.4 0.0 0.003 TL 12.00 PV Pipe: 23 -83.6 6.065 PL 12.00 PF 0.0 18 16.5 0.0 39.6 0.0 0.9 120 FTG ---- PE 0.0 16 16.5 0.0 39.6 0.0 0.000 TL 12.00 PV Pipe: 24 6.3 2.067 PL 192.46 PH 0.1 18 16.5 0.0 39.6 0.0 0.6 120 FTG 4T PH 0.0 19 16.5 0.0 39.5 0.0 0.001 TL 232.46 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 83.6 4.026 PL 12.00 PF 0.0 19 16.5 0.0 39.5 0.0 2.1 120 FTG ---- PE 0.0 17 16.5 0.0 39.5 0.0 0.003 TL 12.00 PV Pipe: 26 -77.3 6.065 PL 5.58 PF 0.0 20 16.5 0.0 39.6 0.0 0.9 120 FTG L PE 0.0 18 16.5 0.0 39.6 0.0 0.000 TL 14.58 PV Pipe: 27 77.3 6.065 PL 189.46 PF 0.1 20 16.5 0.0 39.6 0.0 0.9 120 FTG T PE 0.0 21 16.5 0.0 39.5 0.0 0.000 TL 219.46 PV Pipe: 28 77.3 4.026 PL 5.58 PF 0.1 21 16.5 0.0 39.5 0.0 1.9 120 FTG T FE 0.0 19 16.5 0.0 39.5 0.0 0.002 TL 25.58 PV Pipe: BULKMAIN -204.2 6.065 PL 47.18 PF 0.2 14 16.5 0.0 39.6 0.0 2.3 120 FTG 4L PE 0.0 TOR 16.5 0.0 39.8 0.0 0.002 TL 83.18 PV Pipe: RISER -204.2 6.065 PL 16.00 FE' 0.1 TOR 16.5 0.0 39.8 0.0 2.3 120 FTG C PE 6.9 BOR 0.5 0.0 46.8 0.0 0.002 TL 48.00 PV Pipe: 8"-UG1 -204.2 8.390 PL 110.00 PF 0.1 BOR 0.5 0.0 46.8 0.0 1.2 140 FTG TLG FE 1.9 FLOWTEST -4.0 SRCE 48.8 (N/A) 0.000 TL 199.00 PV NOTES: Calculations were performed by the HASS 7.6 computer program under license no. 3808132110 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.037 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 6.4 ft/sec at pipe 7. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A U N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 2.067 5.00 10.00 3.00 11.00 6.00 1.00 10.00 10.00 10.00 PAGE: A MATERIAL: DTHRD HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 4.026 10.00 20.00 6.00 22.00 12.00 2.00 20.00 10.00 20.00 6.065 14.00 30.00 9.00 32.00 10.00 3.00 28.00 19.00 30.00 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) B T L C B G N Eli Tee LngEll ChkVlv BfyVlv GatVlv NPTee 8.390 31.00 60.00 22.00 78.00 21.00 7.00 60.00 120. 0 WATER SUPPLY ANALYSIS Static: 110.00 psi Resid: 100.00 psi Flow: 1546.0 gpm G A U G P R E S S 60.0 U R E 40.0 p S ± 20.0 -14.7 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) S SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 1/18/2009 C:\HASS77\FILES\PARAMOUNT\SIERRA WIRELESS\SIERRA.SDF JOB TITLE: SIERRA WIRELESS REMOTE AREA A .10/1851 EXT COV HEADS WATER SUPPLY CURVE 120+ \\\\\\\\\\ 100+ * <-100.0 psi @ 1546 gpm I Flow Test Point 90+ P 80+ R I B S I S 70+ U I R I E I 60+ P S I I50+X 40+ 30+ 20+ LEGEND I I, I X = Required Water Supply I 48.82 psi @ 304.2 gpm 10+ U 0 = Available Water Supply I 109.51 psi 8 304.2 gpm +------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) ASo'oeo7 tqCLl IF/re & Building 0 1 ,Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series EC-8 - 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 inch (19,1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY4232 - Pendent, 8.0K TY4232 is a redesignation for C4232. JANUARY, 2005 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 8.0 GPM/psi112 (115,2 LPM/barl'2) TFP223 Page 2 of 6 TFP223 Components: 3/4" ** ESCUTCHEON PLATE 1 - Frame NPT j SEATING SURFACE 2 - Button Sealing Assembly Bulb 1 -M I J8" Compression _________ 2 Screw 3 1/2' _ (54,0 mm) Deflector * * t f1 (l2,7mm)1i11 '1111 I Temperature rating is NOMINAL 1-7" /16 I indicated on Deflector. i:i MAKE-IN mm) ** Pipe thread connections per ISO 7/1 can be provided 6* on special request. FIGURE 1 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINISH (See Note 4) HAZARD TYPE TEMP. BULB NATURAL I CHROME WHITE BRASS PLATED I LIQUID POLYESTER LIGHT PENDENT 135F/57°C Orange Refer to Table B for UL and C-UL ______________ 1,2,3,5 155°F/68°C Red REC. PENDENT 135°F/57C Orange Sensitivity Rating and W/ Style 30 Esc. 1, 2, 3, 5 Refer to Table C for FM 155OF/680C Red REC PENDENT 135°F/57°C Orange Sensitivity Rating w/ Style 40Esc. 1,2,5 155°F/68°C Red NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Temperature Ratings 135°F/57°C and 155°F168°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ........Glass (3 mm dia.) Compression Screw ......... .......Bronze Deflector ............Brass t Registered trademark of DuPont Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be in- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C).. UL and C-UL Listing Requirements The Series EC-8 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and haz- ard group for all of the sprinklers in the design area. With respect to heat sensitivity, the Series EC-8 Sprinklers can be used with unobstructed construction con- sisting of flat, smooth ceilings (in- cluding bar joists) with a maximum pitch of one in six as defined and permitted by NFPA 13. The minimum allowable spacing be- TFP223 135°F 155°F AREA STYLE 16x16 Pendent OR OR 16 x 16 Style 30 Recessed OR OR 16 x.16 Style 40 Recessed OR OR 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR SR 18 x 18 Style 40 Recessed OR SR 20x20 Pendent OR SR 20 x 20 Style 30 Recessed OR SR 20 x 20 Style 40 Recessed SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 135°F 155°F AREA STYLE 16x16 Pendent OR OR 16 x 16 Style 30 Recessed OR N/A 16 x 16 Style 40 Recessed N/A N/A 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR N/A 18 x 18 Style 30 Recessed N/A N/A 20 x 20 Pendent OR OR 20 x 20 Style 30 Recessed OR N/A 20 x 20 Style 40 Recessed N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS Page 3 of 6 Installation The Series EC-8 Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment of an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads, and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten pendent sprin- klers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprinklers using only the W-Type 4 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). tween the Series EC-8 Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to ceiling distance. Page 4 of 6 TFP223 DESCRIPTION AREA GPM PSI TY4232 (K=8.0) PENDENT 16 x 16 26 10.6 18x18 33 17.0 20x20 40 25.0 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS - 2-7/8" DIA. 1/2±1/8' (73,0 mm) 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF II (57,2 mm) SPRINKLER /8" I FITTING (3,2 mm) /JL MOUNTING MOUNTING SURFACE TIN PLATE CLOSURE 1-1/4' (31,8 mm) 1" (25,4 mm) FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8 DIA. - 9/16±1/4" (73,0 mm) 3/4(19,1 mm) r (14,3±6,4 mm) _ 2-1/4' DIA. 1/4(64mm) FACE OF I (57,2 mm) SPRINKLER I •7J I 1/8' FITTING L._I (3,2mm) / \ MOUNTING SURFACE// OUNTING OUNTING PLATE CLOSURE 6"33,3mm 13/16(20,6mm) FIGURE 3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS L fl I U WRENCH LUGS FIGURE 5 W-TYPE 4 RECESSED SPRINKLER WRENCH Care and Maintenance The Series EC-8 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers that are found to be leaking or exhibiting visible signs of Corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to TFP223 Page 5 of 6 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: TY4232, (specify temperature rating), Extended Coverage Pendent Sprinkler with (specify finish), P/N (specify). 135°F157°C Natural Brass .............PSN 50-801-1-135 White Coated .............PSN 50-801-4-135 White (RAL9O1O). .......... PSN 50-801-3-135 Chrome Plated ............PSN 50-801-9-135 l55°FI68C Natural Brass .............PSN 50-801-1-155 White Coated .............PSN 50-801-4-155 White (RAL9O1O). .......... P5W 50-801-3-155 Chrome Plated ............PSN 50-801-9-155 Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style (30 or 40) Recessed Escutcheon with (specify finish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL9O1O). .......... PSN 56-705-3.011 Brass Plated ..............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700.9-010 White Color Coated ........PSN 56-700-4-010 White (RAL9O1O). .......... PSN 56-700-3-010 Brass Plated ..............PSN 56-700-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1 -001 Specify: W-Type 4 Recessed Sprinkler Wrench, P/N 56-875-4-001 Page 6 of 6 TFP223 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCD /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB - 2.8,4.2,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TV-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.0K, 314"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I Page 2 of 10 TFPI7I ESCUTCHEON PLATE SEATING SURFACE -r- 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 7/16(11,1 mm) STYLE 10 or 2( NOMINAL RECESSED MAKE-IN ESCUTCHEON DEFLECTOR 6 (11,1mm) H / 7/16" 1 _5 NOMINAL MAKE-IN 2-3/16" " (55,6 mm) I I/2"NPT f SSP DEFLECTOR * 1- 2-7/8' (73,0 mm) DIA. -1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI 13 1) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) PLATE SEATING NOMINAL SURFACE 12 MAKE-IN 23il6' NPT (55,6 mm) f 1-1/2" (38,1mm) STYLE 10 or 20 RECESSED * ESCUTCHEON I]II(SJ NOMINAL 4 NOMIr FLATS 4 SSP DEFLECTOR ( 2-7/8" (73,0 mm) DIA, PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) CROSS SECTION TFPI7I Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2 MAKE-IN NPT F_ 2-3/16° \ A (55,6 mm) 1-1/2" (38,1mm) STYLE 100r20 RECESSED ESCUTCHEON SSU DEFLECTOR 1 7/16" I (11,1 mm) NOMINAL ; MAKE-IN 2-3/16° WRENCH ______ __ 55,6 mm FLATS 1/2"NPT t SSP DEFLECTOR - 2-7/8 (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION '1 - Frame 3 - Sealing 4 - Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2"(12,7 mm) PLATE SEATING NOMINAL SURFACE a" MAKE-IN NPT 2-5/16" _ (58,7 mm) 1-9/16" (39,7 mm) / 3/4' NPT UPRIGHT WRENCH FLATS SSP DEFLECTOR * I 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR 1 - Frame 3 - Sealing 4- Bulb 6- Detector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw -r- 2-1/4" (57,2 mm) 1-9116" (39,7 mm) - ssP* DEFLECTOR CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. !hli CH S Page 4 of 10 TFPI7I 1/2' NPT 7/16(11,1 mm) NOMINAL MAKE-IN ssu * DEFLECTOR FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/bar1l2) K = 4.2 GPM/psil/2 (60,5 LPM/bar112) K = 5.6 GPM/psi1/2 (80,6 LPM/bar1l2) K = 8.0 GPM/p51112 (115,2 LPM/bar1I2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL I CHROME I WHITE" LIQUID BRASS PLATED IPOLYESTER 135"F/57°C Orange PENDENT (TY1231) and 12,3,5 155"F/68"C Red 175°F/79°C Yellow 2.8 1/2" UPRIGHT (TY1131) 200°F193°C Green 286"F/141"C Blue NPT 135°F/57°C Orange RECESSED PENDENT 155"F/68°C Red 175°F/79°C Yellow (1Y1231)* Figure 6 1, 2, 5 200°F/93°C Green 135°F157°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY1231) Figure 7 200"F/93°C Green 135"F/57°C Orange PENDENT (TY2231) "F/68° 155 C Red 175"F179"C Yellow and UPRIGHT 200°F/93°C Green 4.2 1/2" (TY2131) 1,2 286"F/141°C Blue 135°F/57"C Orange NPT RECESSED PENDENT 155"F168"C Red 175"F/79°C Yellow Y2231)* Figure 8 200°F/93"C Green 135"F/57°C Orange RECESSED PENDENT 155"F168°C Red 175°F179°C Yellow (TY2231) Figure 9 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I - SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME I WHITE LEAD I LIQUID BRASS PLATED IPOLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) and 1,23,45,6,7 1,2,3,5 155°F/68"C Red 175F/79°C Yellow 5.6 UPRIGHT (TY3131) 1/2" 200"F/93"C Green 286°F/141°C Blue NPT 135"F/57"C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231)* 155"F/68°C Red 175"F/79°C Yellow Figure 10 200"F/93°C Green 135F/57°C Orange 1,2, 3,4, 5 N/A RECESSED PENDENT (TY3231)" 155°F/68"C Red 175°F/79°C Yellow Figure 11 200"F193°C Green 135"F/57°C Orange PENDENT (1Y4231) and UPRIGHT 1,2, 3,4, 5,6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93"C Green 8.0 3/4,, (1Y4131) 286"F/141°C Blue NPT 135F/57°C Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)* 155"F/68°C Orange 175°F/79°C Red Figure 12 200F/93°C Yellow 135"F/57°C Orange 1,2, 3,4, 5 N/A RECESSED PENDENT (TY4231) 155F/68°C Red 175°F/79°C Yellow Figure 13 2007/93°C Green 135°FI57C Orange 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 1,2,4,5,6 1,2,5 155°F/68"C Red 175°F/79"C Yellow 200°F/93"C Green 286"F/141"C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers: however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD BRASS I PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4,, RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2' 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-7/8" DIA. - 518±1/4" (73,0 mm) 3/4"(19,11 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4"(6.4 mm) FACE OF mm) 1 *(3.u2 NTING I SPRINKLER ATEFITTING /8" 3,2 mm) MOUNTING SURFACE CLOSURE SERIES TY-FRB 13/16(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/811/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF 2mm) I MOUNTING I SPRINKLER PLATE FITTING 1/8" MOUNTING SURFACE/ •.'. CLOSURE SERIES 1-1/4(31,8 mm)1 TY-FRB 3/4"(19,11 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 - 2-7/8" DIA. 1/2±1/8" I (73.0 mm) 1I2"(12,7mm) [(12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) 1 FACE OFqR 572 mm) i1 I MOUNTING SPRINKLE _PLATE FITTING 1/8" (32mm) SURFACE 1-5/16"(33,3 mm) MOUNTIN CLOSURE SERIES TY-FRB 1-1/16" (27,0mm). FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 1/2±1/8" (73.0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I FACE OF (57 2mm) MOUNTING I I SPRINKLER PLATE I I / 1/8" (32 FITTING ? mm) I T__\ MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31.8 mm)1 1Y-FRB 1"(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic Sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFPI7I - 2-7/8' DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-114" DIA. 1/4" (6,4 mm) I FACE OF MOUNTING (57,2 SPRINKLER PLATE FITTING 1/8" (3,2mm) MOUNTING t SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TYFRB 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4"(6,4 mm) (57,2 mm) I I FACE OF I MOUNTING PLATE SPRINKLER FITTING _______ 1/8" I _____ __ _________________ (3,2 mm) /k/ L H MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2'(12.7 mm) r (12,7±3,2 mm) H— 2-1/4" DIA. 1/4"(6.4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE 1/8" FITTING mm) I f \ MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2'(12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING PL I SPRINKLER ATE I FITTING 1/8 2 m " I , ( 3,m) T-7- MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-Up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2°NPT) TY2231 370 5.6K UPRIGHT (1/2'NPT) TY3131 371 5.6K PENDENT (112NPT) TY3231 390 8.0K UPRIGHT (3/4°NPT) 1Y4131 391 8.0K PENDENT (3/4'NPT) TY4231 360 8.0K UPRIGHT (1/2NPT) 1Y4831* 361 8.0K PENDENT (1/2"NPT) TY4931* PIN 57-XXX-X-XXX I I - MODEL/SIN TEMPERATURE RATING * Eastern Hemisphere sales only. SPRINKLER 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED rmmw_l 816107A11101 135 135°FI57C 155 155°F/68°C 175 175°F179°C 200 200°F193°C 286 I 286°F/141°C Page 10 of 10 TFPI7I TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness for a oar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446