Loading...
HomeMy WebLinkAbout5962 LA PLACE CT; 150; FPC2018-0150; PermitPERMIT REPORT ((7city of Carlsbad Print Date: 11/03/2021 Job Address: 5962 LA PLACE CT, # 150, CARLSBAD, CA 92008-8807 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120620600 Track #: Valuation: $17,038.56 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: SPEC SUITE 150 -SPRINKLER TI (19 HEADS) (FORMERLY SUITE 185) Permit No: FPC2018-0150 Status: Closed - Finaled Applied: 05/15/2018 Issued: Finaled Close Out: 11/03/2021 Inspector: Final Inspection: FPContractor: TOTAL FIRE PROTECTION INC 1611S MELROSE PL #244 VISTA, CA 92081-5471 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $0.00 Balance Due: $536.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Tfi r- 'rote in inc. MATERIAL DATA SUBMITTA Spec Suite 150 5962 La Place Court, Suite 150 Carlsbad, CA 92008 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 . 11-12 Fittings Tyco Ductile Iron Fittings Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Reliable F1FR56 Sprinkler 20 Hanger Afcon Fig. 100 Beam Clamp 21 Hanger Afcon Fig. 162 Retaining Strap 22 Hanger Afcon Fig. 300 Ring Hanger 23 Hanger Afcon Fig 655 All Thread Rod 24-25 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohncgmaiI.com DynamThreado O Full Line Sch-40 Replacement Dyna Threada offers the life expectancy of $ch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 0 S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (P <i~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40fDyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). iTItfThii NPS Nominal I.D. Wt. WI. (H20 Filled) Pcs/ WtIl.itt (21') WtJLift (241) WI/LIft (25') In; mm in; aim Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs;Kg Lbs;Kg Lbs;Kg 1 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2* 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 tqccl/Flow Control 1' 16100 S. Lathrop Harvey, IL 60426 dhed 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna-Thread S Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here S Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WII1.11111 (21') Wt/I.ift (24') WIfl.ilt (25' In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1051 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2' 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 1034 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured Us L jj with Exterior galvanized coating. BIT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: S Engineer: Specification Reference: System Type: Locations: Comments: (II S3 -4 tqC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 S S Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco5 Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI 131.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or detect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de Nemours and Company or its affiliates. TFPI7IO Page 2of 10 TFPI7I0 Nominal Pipe Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DNJ20 (33,3) (0115) 1 1.50 0.48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 86782 C C S r A it FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW Figure 811 Figure 813 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 1 TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 .94 1.00 2.70 DN65 (68,3) (39,6) (1,49) 86204 (49,3) (25,4) (1,22) S TFPI7IO Page 3 of 10 FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Inches Inches Inches Inches Inches Weight Lbs. Part Number DN (mm) (mm) (mm) (mm) (kg) 314x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20x15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 0N25 x 15 (31,8) (35,1) (14,2) (20,6) (0120) 1 x314 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4 x 1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32x15 (33,3) (38,1) (160) (23,9) (0,29) 1-1/4x3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-114x1 1.56 1.68 0.88 1.00 0.77 86214 0N32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 0N40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7). (0,45) 1-112x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 0N50 x 20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 0N50 x 25 (44,4) (52,3) (50,8) (33,3) (0,72) 2x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2x2 2.38 2.63 1.25 1.88 3.01 86262 0N65 x 50 (60.5) (66,8) (31,8) 1 (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 0 S S TFPI7I0 Page 5of 10 Nominal Pipe Size Approx. ANSI Inches Weight Part DN Lbs. Number (kg) 1/2 0.18 72779 DNI5 (0,08) 3/4 0.26 72778 DN20 (0111) 1 0.44 72755 DN25 (0,20) 1-1/4 0.54 72754 0N32 (0,24) 1-1/2 0.71 72753 0N40 (0,32) 2 1.15 72752 DN50 (0,52) 2-1/2 2.29 72758 DN65 (1,04) S T 1_Al L 0 L B FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 A B Approx. A B Inches Inches Weight Part Inches Inches (mm) (mm) Lbs. Number (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 (28,7) (14,2) (0,15) (35,1) (7,9) 1.31 0.75 0.50 86341 1.63 0.56 (33,3) (19.0) (0,23) (41,4) (14,0) 1.50 0.81 0.85 86230 1.75 0.38 (38,1) (20,6) (0,38) (44,4) (9,7) 1.75 1.06 1.30 86231 2.00 0.56 (44,4) (26,9) (0,59) (50,8) (14,0) 1.94 1.19 1.63 86232 2.19 0.75 (49,3) (30,2) (0,74) (55,6) (19,0) 2.25 1.50 2.63 86233 2.63 1.13 (57,1) (38,1) (1,19) (66,8) (28,7) 2.69 1.56 4.55 86234 3.00 0.75 (68,3) (39,6) (2,06) (76,2) (19,0) S TFPI7I0 Page 6of 10 S S I Page 7 of 10 TFPI7IO C7 FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part ON Lbs. Number (mm) (mm) (mm) (mm) (mm) (mm) (kg) 1-112x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 DN40x32x15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,1) (0.47) 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (38,1) (36,6) (44,5) (19,0) (19,0) (30,1) 1-1/2x 1-114x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 0N40 x 32 x 25 (41,4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40 x 32 x 50 (55.6) (54,1) (50,8) (36.6) (36,6) (57,1) (0,88) 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 0N40 x 40 x 15 (36.6) (36,6) (42,9) (17,5) (17,5) (28,7) (0,52) 1-1/2 x 1-1/2 x 3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0.56) 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2 x 1-1/2 x 1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0.68) 1-1/2x1-112x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40 x 40 x 50 (55,5) (55,5) (50,8) (36,6) (36,6) (31.7) (0.91) 2x1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DN50x25x50 (57,2) (50,8) (57,2) (38,1) (33,3) (38,1) (0.99) _______ 2x1-1/4x2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 86267 DN50 x 32 x 50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 2x1-112x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (38.1) (36,6) (47,8) (19,0) (17,5) (33,3) (0,68) 2x1-1/2x314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 DN50x40x20 (41,4) (38,1) (49,3) (22,4) (19.0) (35.0) (0,73) 2 x 1-1/2 x 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50x40x25 (44,5) (41,4) (50,8) (25,4) (22,4) (33.3) (0,75) 2x1-1/2x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 DN50 x 40 x 40 (52,4) (49,2) (55,5) (333) (30,2) (36,6) (0,92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (57,1) (55,5) (6315) (38,1) (36,6) (38,1) (1,07) 2x2x1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 86222 DN50 x 50 x 15 (38,1) (38,1) (47,8) (19,0) (19.0) (33,3) (0,68) 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49.3) (22,4) (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 DNSO x 50 x 25 (44,5) (44,5) (50,8) (25,4) (25,4) (33,3) 2x2x1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28.7) (36.6) (0.93) 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50.8) (50,8) (55.6) (31,8) (31.8) (38,1) (0,96) 2x2x2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 86227 DN50 x 50 x 65 (66,8) (66,8) (60,5) (44,5) (47,8) (36,6) (1,66] 2-1/2x2x3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65 x 50 x 20 (44.5) (41,4) (58,7) (15,9) (22.4) (44,5) (1.01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO S uuiimi iiiiiiu Ll FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) 1/2 (kg) 8 0.15 72776 1.88 0.81 0.47 86207 0.94 0.1086292 DN15 (0,06) (47,8) (20,6) (0,21) (23,9) F(22,4) 0 0.22 72777 (0,04) 3/4 2.00 0.94 0.66 86275 1.13 0.18 86293 DM20 4) (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 8 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 DM32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0123) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 0N50 (38,1) (0,43) (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 0 TFPI7IO Page 9 of 10 S FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - 0N15 x 15 (38,1) (0109) 1 112x112 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4x1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - - - (43,2) (17,5) (0,17) I x 1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25x 15 - - (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 - - (26,9) (0,08) (43,2) (12,7) (0,24) 1-1/4x1 1.19 0.31 72763 - - - - DN32 x 25 - - - (30,2) (0,14) 1-1/2x1 1.25 0.53 72757 - - - - DN40x25 - - - (31,7) (0,24) 1-1/2x1-1/4 1.25 0.35 72764 - - - - DN40x32 - - (31,7) (0,10) 2x1 1.38 0.75 72759 - - - - DN50 x 25 - (35,1) (0,34) 2x1-1/4 1.38 0.69 72761 - - - - DN5O x 32 - - (35,1) (0,31) 1 1.38 0.62 72775 - - - - DN50x40 - (35,1) (0,28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 3 S tJJC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description Listing/Approval information The Figure40-5Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las with theapp/icable standards of the National Fire Protection Association, in addition to the standards ofanyotherauthorities ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type III Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade 'E" EPOM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade 'E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Are Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership withlyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards ofanyotherAuthoritiesHaving Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Are Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforif,anyotherobligationinconnectionwifh the sale of products or parts of products. Tyco Are Productsshallnotberesponsibleforsprinklersystem designerrorsorinaccurateorincompletelnfomiation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHE11-IERTYCOFIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. 1HEFOREJThV WARRANTY IS MADE IN LIEU OF ANYAND ALL OilIER immum Effm Oil Page 1 of 2 September 2004 TFPI 720 3f12 TFP172O Figure 40-5 Strap rtem Devon 1 Housing 2 Gasket Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) i' X 1I & 11V?x ? 6 2/'x 1 4 for these outlets is specified in eel 11W of 1 inch Schedule 40 (C=120} pipe. nch outlets can be used with a nipple leading to a spthifder. These fittings should be used eaetcaiKy calculated systems only. Pipe Nominal Dimensions Hole Net Size Size WI. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. ii.' x Ile 2.00 1.50 3.50 1.20 Wis 0.84 50.8 38.1 88.9 30.5 302 1 0.4 1W xW 2.00 1.50 3.50 1.20 the 0.88 50.8 38.1 88.9 1 30.5 30.2 0.4 iv" x 1' 2.31 1.68 3.50 1.20 1/6 1.13 58.7 42.7 88.9 30.5 30.2 0.5 iw° x ,%- 2.12 1.62 3.50 1.32 1/i& 0.84 53.8 41.1 88.9 33.5 30.2 0.4 VI? x 2.12 1.62 3.50 1.32 13/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1V2" x t' 2.43 1.80 3.50 1.32 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2 x 112, 2.36 1.86 3.74 1.55 the 0.88 59.9 47.2 95.0 39.4 30.2 0-4 2 x 3W 2.36 1.66 3.74 1.55 13/te 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2x 1" 2.67 2.04 3.74 1.55 13/i 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21!? 2.61 2.11 4.25 1.80 13/16 0.90 663 53.6 108.0 45.7 30.2 0.4 2W X3I4tm 2.61 2.11 4.25 1.80 the 0.99 66.3 53. 108.0 45.7 30.2 0.4 2'!? x r 2.92 2.29 4.25 1.80 13A6 121 74.2 58.2 108.0 45.7 30.2 0.5 Note: Outlet threads conforming to ISO 7-1 are available, contact Tyco Fire Products. 12 N the Designer's respcnsibihty to select podscts suitable for the intended service and to ensure IS 01 - and performance data is not exceeded. Always read and understand the installation 90 ,dons (n-i-boo). Never remove any piping component or correct or modify any piping deficiencies without pvessurzng and draining the system. Materiel and gasket selection should be verified lobe compatible t specific application. Certified Company RE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely XLH Upright XLH Pendent Conventional c Recessed PendentJF1/F2 Recessed Pendent/FP XLH Recessed Pendent F1/F2 4 XLH Recessed Pendent FP manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Upright Pendent Vertical Sidewall Horizontal Sidewall H4 Recessed Concealed Horizontal Sidewall Pendent Bulletin 014 Rev. L bile Model Fl FR Series Quick Response Standard Spray C J C -J r_ Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Ell Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Spunkier Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH 'NSF Certified to NSF/ANSi Standard 61 Annex C EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1 475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, is F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be • exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. */fl tie Deflector (XLH Only) Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL1) K5.6 Quick 1/2" NPT See See F1FR42 **F1 FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" Fl FRXLH Ratings" Table. F1FR28 K2.8 "Low Lead Sprinklers available only with Temperature Rating 200°F/93°c Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDAAlloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. S Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor Sprinkler _______________ Approval Sprinkler Identification Number (SIN) Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2"05mm)1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1,2,3,4,6 7/16' (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA1413 4 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA1421 14 RA1411 4 Conventional-Install in Upright or Pendent Position 15mm" 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 J RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US J Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm)') 1/2" NPT (R1/2) [ 5.6 I 80 2.25" (57mm) 1,5 RA1415 7/16(11mm) 1/2" NPT (R1/2)[_4.2 _60 2.25"(57mm) 1,5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. S *DuPont Registered Trademark 3. Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) S [ S Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(l) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA 1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler 1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) 1/2" NPT (R1/2) 1 4.2 60 1 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions - 5 URIC RUNT AGAINST GEIN'RUR I / FACE OF FITTING I To FACE OF ECU/NC DIMENSION \ FI.IICEECW AT IBUM RECESS La VTM - 4/8 lnLllrlrlr- J I AT- RECESS 1:1,11T2~1,- VA5° - AT MAXIMUM RECESS I -/R2&6,nmj AT MINIMUM RECESS - -5/a 41 3m,,, - Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 I I S I/2 REDUCER 2 HOLE IN CEILING 2 5/I6 DM. Cup .:JCEXIAG FACET OF FInING TO FACE OF CEILING VIMESSON AT ABWMUM RECESS: I-I/2TINJ AT MINIMUM RECESS I72S4.',,,,,J JTI2.7Rvf It AAT T MUM RECESS - 9/lOfI4.3mmJ MINIMUM RE - ?725.4a,rRJ - (aZ6.nmJ Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US I Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT(R1/2) 5.6 80 2.25" (57mm) 1,2,3 RA1 485(2)(3) 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon)* Plated - cULus listed corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4. Horizontal Sidewall S Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifice Thread Size Nominal K Factor _________________ Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identification Numbers (SIN)Hazard US Metric Light Hazard Ordinary ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant S I I (7) I 15/16" OL4 I 4-12" ..(,L [IO1,6mm-304.8mm] /32" OIA. CEILING TO 2.2mm] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER _ WRENCH ROSS. Fl ESCUTCHEON 3/4(19mm] ADJUSTMENT H F2ESCUTCHEON 1/2'r12. 7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = I "[25.4mm] AT MINIMUM RECESS 3/8(9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[I9mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE OIA. [57.2mm] 1" x 7/2' REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS = 1-3/8(34.9mm] AT MINIMUM RECESS = 2-1/16(52.4mm] Iml F2 ESCU AT MAXIMUM RECESS = 1-5/8(41.3mm] AT MINIMUM RECESS 2-1/16"[52.4mm] (3 RECESSED HSW w/F1ORF2ESCUTCHEON (I) FM APPROVED FOR 4" - 6" [701.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K"Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover 1/2"(15mm) 5.6 80 ½" NPT F1 FR 1350F/570C 1350F/570C 100°F/380C Orange 1 RA1414 1/2"(15mm) 5.6 80 1 112" NPT F1 FR 1550F/680C 1350F/570C 100°F/380C Red 1 1,4(1),6 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1 FR 1750F/790C 1650F/740C 100°F/38°C Yellow 1 RA1414 1/2"(15mm) 5.6 80 ½" NPT F1 FR 200°F/930C 1650F/740C 1501F/650C Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K"Factor I I Thread Size I Model Temp. Rating Max. Ambient Bulb Color Approvals Sprinkler Identification US Metric Sprinkler I I Cover Temp Number(SIN) 1/2"(15mm) 5.6 _80 1/2" NPT _F1FR56LL 200°F/930C _1650F/740C 1500F/650C Green 1,5 RA1414 *DuPont Registered Trademark 0 S S C I " x 1/2'S REDUCING TEE OR ELBOW —E '' 2 5/i6 A— HOLE IN CEILING CUP FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING COVER / ADJUSTMENT / COVER PLATE — ASSEMBLY SPRINKLER CONCEALED, 1/2" ADJUSTMENT 07FcOA Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½" orifice, 1/2" NPT (R1/2), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FlFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 1 x 1/2' REDUCING TEE OR ELBOW 8 IN 2 5/16' 0/A '1 .1 HOLE"CEILING CUP I 1 1/2'MAX. I--.---.-.-'—' FACE OF FITTING I TO FACE OF CEILING DIMENSION CEILING 5116" MAX. 314 COVER ADJUSTMENT COVER PLATE H ASSEMBLY 3 5/16" 0/A SPRINKLER CONCEALED, 5/16" ADJUSTMENT 000 Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C OF Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High 141 1 286 1 2250F(1070C) Blue " Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for light hazard" only, while FM limits use for same hazard with F2 escutcheon only Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) *DuPont Registered Trademark Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate(l) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate0 Electroless Nickel PTFE(TefIon )*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass 3> Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint 21161 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish appliesonly to RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. S 7. S 100 BEAM CLAMP SMALL MOUTH S ze A)US SIZE - 3/8" and 1/2" rod. MATERIAL - Ductile iron with hardened cup point set screw and jam nut. FINISH - Plain, Electro-Galvanized and H.D.G. and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL- Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-171E Type 19 and 23 and Manufactures Standardization Society ANSI/MSS-SP-58 Type 19 and 23. FUNCTION - To hang from steel beam with flange thickness of less than 3/4". INSTALLATION - Per NFPA #13 - 3/8" rod will support 1/2" thru 4" pipe and 1/2" rod 5" thru 8" pipe. Install in accordance with ANSI/MSS-SP-69. Torque - 3/8"= 60 inch pounds. Torque - 1/2"= 125 inch pounds. In the absence of a torque wrench, the set screw should be finger tightened and then an additional 1/3 turn applied to the set screw. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back prevents twisting during installation. ORDERING - Part #, rod size and finish. S Index IA 1 (T) S 162 UNIVERSAL - RETAINING STRAP Nut optional, if insufficient rod dimension fl SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING - UL in US and CANADA. PATENT - No. 5,897,088 FUNCTION - To offer more secure fastening of Beam Clamp to beam when danger of movement might be expected. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts per good installation practice (See drawings provided) ORDERING - Part # and overall length. S Index 1 ')Iflfl () S 300 RING HANGER I thru 4 Inch pipe 1/2 and 3/4 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 17 1 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1thru4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE ROD 1/2 318 400 10 3/ 3/8 400 20 10 1 3/8 400 s 10 1 114 3/8 400 1 32 10 1/2 3/8 400 40 10 2 3/8 400 50 10 21/2 3/8 600 65 to 3 600 80 10 31/2 318 600 1 to 3/8 1000 100 10 5 1250 125 12 6 112 1250 150 12 8 1/2 1 1250 200 1 12 * Order Part #300m Note: 1/2 Ring Hanger not <FM> approved F~ 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 1810 1610 L5/8 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. S 2/00 E3 WOOD - 1/4" Rod (Veftical Mount) Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Box Qty Weight (per l) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 CST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 GST300 1 3 1/4 100 7.50 1000 24 IGST600 1 6 1/4 50 9.00 500 S WOOD - Sammys i #14 (Item #100-black) Sammys 1/4", 3/8" rod WOOD - 3/8 Rod r (Veitical mmii Use #14 Nut Driver (Item #100) Approvals Item # Model Shk Lgth Shk Dia FMlest Loa lb. ULTest Load lb. WFMActual Pipe Size Pullout Box Qty 10 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 CST 10 1 1/4 210# - 7/16 6704 - 3/4"OSB Ply 100 UL•FM•NFPA 12 CST 20 2 1/4 9404 850# 3/4-2 1/2 17604-Fir 100 UL-NFPA * 27 CST 25-380 2 1/2 3/8 15004 4 21134 - Fir 50 UL-FM-NFPA 13 GST30 3 1/4 14754 15004 3/4-4 2060# -Fir 100 NFPA 403 CST 40 4 1/4 2180#-Fir 50 NFPA 14 1GST60 1 6 1 1/4 1 2230# - Fir 50 #I4SW (Item #101-red) Sidewinders & Sammys 112" rod Y[III] I V)lilRod r&ni 1ITTTT1 Use #14SWNutDriwr (Item #101) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case Qty 8 CST 2 2 1/4 17604- Fir 50 7.00 500 * 06 CST 2.5-380 21/2 3/8 21134-Fir 50 1000 500 15 IGST3 1 3 1 1/4 1 22754- Fir 1 50 1 10.50 500 16 ICST4 1 4 1 1/4 1 2180#-Fir 50 10.60 500 17 JGST6 1 6 1 1/4 1 22304- Fir 50 10.95 500 Not less than 2" nominal width (11/2") q Wood Joist TJI Joist/ Truss Consult truss manufacturer for recommended installation point *pre. drilling may be required for items #27 and #06. Tools available on page 9. S Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance For vertical use. Install in center oflowerface. 13 24 Page 4 Note: &re ws must be installed with appropriate nut driver to comply with warranty WOOD —Sidewinders It #I4SW (Item #101-red) Sidewinders & Sammys 112" rod '!(III] iiRod ri(Itmizontall IITIT1T1 Use #14SWNut Driver (Item #101) Item# Model IShk Lgth l Shk Dia I I I Actual Shear/Pullout I Box Qty Weight (per 100) ICase Qty I 4016 SWG 100 1 1/4 100 7.50 I 1000 300 SWG 200 2 1/4 1725# -Fir 100 8.00 1000 L![11I] I,IIRod 'Use #I4SW ri rtflviunl9LUITmTh Nut Driver (Item #101) Approvals Item # Model Shk Lgth Shk Dia IL Test Load lb. UIJFM Pipe Size ActualBox Shear/Pullout Qty Weight (per 100) 18 SWG 10 1 1/4 100 6.00 UL•NFPA 19 SWG20 2 1/4 1250# 3 1725# -Fir 100 7.00 UL•NFPA * 26 1 SWG25-380 21/2 3/8 1 1500# 1 4 2249# -Fir 1 50 1 10.25 25 SWG30 3 1/4 50 8.50 S Not less than 2" nominal width (1112") up to3112" pipe; not less than 3" nominal width 4" & 5" pipe Floorjoist r TJI Joist! Truss Consult truss manufacturer for recommended installation point. *pre_drilling may be required for item #26. Tools available on page 9. 113 Minimum 2112" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: I This requirement shall not apply to 2" orthicker nailing strips resting SHEETROCK -Toggle on top of steel beams. 1I I N I (II VEI 1Y rinm Mount) Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty (per 100) 71 SST 300 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock #14 (Item #100-black) Sammys 1/4,318" rod MI I N (II ii: im r&Yflflt1 Mount) 'Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100) 70 SST 30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock Note: Screws must be installed with appropriate nut driver to comply with warranty Prestressed Concrete 47 C2 E Page 5