HomeMy WebLinkAbout7104 KINGFISHER LN; ; AS010176; Permit11/3/21, 3:47 PM AS010176 Permit Data City of Carlsbad Sprinkler Permit 7104 KINGFISHER Job Address: LN Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: PC #: Permit No: AS010176 Status: ISSUED Applied 9/18/2001 Approved: 10/16/2001 Issued: 10/16/2001 Inspector: Project Title: AVIARA TIME SHARES -PH 5 Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 486.5 0 486.5 0 1/1 :T7THU 15:03 CARLSBAD FIRE DEPT FAX NO. 6199290256 P.03 / Carlsbad Fire Department 1 I Fire Protection System Application t Information Fee Check or fill in pertinent information for type of permit you are submitting. I / AS - Automatic Sprinklers 2. f Commercial Residential .j i '? (Z, Tenant Improvement - New Construction -1- (••• Number of heads per system /> 131 It System # 1 0 ','- Heads J System # 9 c' Heads_.. 4-8 System # '01 Heads --a-ce System # Heads co 9 4P System# IOZ Heads 6- System # Heads. FA Fire Alarm Number of devices _______ V FS - Fixed Systems - Circle One Hood and Duct, Halon, Special Chemical Agent, Standpipe, -------------- Spray Booth, or Appliance . There may be an additional charge of $40.00 per 1/2 hour for failed inspections. Total Amount of Fees Paid B. Address of job siteL Suite # '- I I - -U Ar, I' 7Io4,.- I,O, 1 I2Z J (7J3,i341h(4O e'i UO/ J CI235j' loll \ 50 °'°0, I 5O\O\b;— KO I q 0 ~, 50 1? 4 353 Asoo1% 0**# 1 oIZ2.. - Fire Protection by Computer Design SCHMIDT FIRE PROTECTION 4760 MURPHY CANYON ORAD SAN DIEGO CA 92123 858-279-6122 Job Name : VILLA 4 HEAD CALC. A Building : 51.52.53.54.55,56 and 57 Location 7VILLA!S @ KINGFISHER LANE System Contract Data File : A-VILLA.WXF Computer Programs by 1-lydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 2 VILLA 4 HEAD CALC. A Date HYDRAULIC DESIGN INFORMATION SHEET Name - VILLA 4 HEAD CALC. A Date - 9-6-2001 Location - 7VILLA'S @ KINGFISHER LANE Building - 51.5253.54.55.56 and 57 System No. - Contractor - ROEL CONSTRUCTION CO. Contract No. - Calculated By - R. W Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height VARIES OCCUPANCY - VILLA STYLE TIME SHARE UNITS - Type of Calculation: ( )NFPA 13 Residential (X)NFPA 13R ( )NFPA 13D Number of Sprinklers Flowing: ( )1 ( )2 (X)4 )Othe SEE CALC.'S B~TH~RU~EFOR SINGLE ~ HEA ~ DCAL~C'S )Specific Ruling ade Date Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 16.4 Psi (i (X) Wet ( ) Dry MAXIMUM LISTED SPACING 20 x 20 Deluge ( ) PreAction Domestic Flow Added - NONE Gpm Sprinkler or Nozzle Additional Flow Added - NONE Gpm Make CENTRAL Model OPTIMA Elevation at Highest Outlet - 30.50Feet Size 7/16 K-Factor 4.2 Note: Temperature Rating 155 Calculation Gpm Required 68.2 Psi Required 108.763 at test Summary C-Factor Used: Overhead 150 Underground 150 S Y S T E M D E S I G N W Water Flow Test: A Date of Test - 10-10-95 T Time of Test - E Static (Psi) - 118.86 R Residual (Psi) - 114.36 Flow (Gpm) - 1257 S Elevation - 0 Pump Data: Tank or Reservoir: Rated Cap. Cap. @ Psi Elev. Elev. 0 Other Well Proof Flow Gpm 5 i ' P Location: FOUR SEASONS POINT - SEE BREAKDOWN ON SITE PLAN P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CHMIDT FIRE PROTECTION VILLA 4 HEAD CALC. A City Water Supply: Cl-Static Pressure: 118.86 PSI C2-Residual Pressure: 114.36 PSI C2-Residual Flow: 1257 GPM Page 3 Date Pump Data: - - 1.OfI. iZ' Di-Elevation: 12.560 PSI D2-System Flow:68.2 GPM D2-System Pressure:108.763 PSI Hose ( Adj City ):0 GPM Hose ( Demand ) :0 GPM Safety Margin: 10.077 PSI I / 7 - )2 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85 omputer rograms by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 4 VILLA 4 HEAD CALC. A Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Added Req. Req. 17 .1 170 7 15.21 .1 130 7 17.42 .1 130 7 18.57 .1 130 7 1 29 4.2 16.38 na 2 29 4.2 13.11 na 3 30.5 17.07 na 4 28 4.2 17.2 na 5 30.5 18.71 na 7 29 4.2 19.56 na 6 30.5 23.65 na 8 30.5 24.02 na 6 30.5 23.65 na 10 30.5 31.87 na 9 30.5 64.9 na 11 8.5 80.63 na 12 3 90.32 na 13 0 92.38 na BKF1 0 97.91 na BKF2 0 105.77 na SRC 0 108.76 na The maximum velocity is 16.72 and it occurs in the pipe between nodes 5 and 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 5 VILLA 4 HEAD CALC. A Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIUL Eqv. Ln. Total Pf Pn 1 17.00 1.101 26.500 16.383 K Factor = 4.2 to 150 -0.650 3 17.00 0.0504 26.500 1.335 Vel = 5.729 17.00 17.068 K Factor = 4.11 2 15.21 .874 36.500 13.112 K Factor = 4.2 to 150 -0.650 3 15.21 0.1262 36.500 4.607 Vel = 8.134 3 17.00 1.101 10.000 17.068 to 150 5 32.21 0.1643 10.000 1.643 Vel = 10.854 32.21 18.711 K Factor = 7.45 4 17.42 .874 16.000 17.199 K Factor = 4.2 to 150 -1.083 5 17.42 0.1623 16.000 2.596 Vel = 9.316 5 32.21 1.101 13.500 18.711 to 150 6 49.63 0.3656 13.500 4.935 Vel = 16.725 49.63 23.646 K Factor = 10.21 7 18.57 .874 28.000 19.556 K Factor = 4.2 to 150 -0.650 8 18.57 0.1826 28.000 5.113 Vel = 9.931 18.57 24.019 K Factor = 3.79 6 17.57 1.101 7.000 23.646 to 150 8 17.57 0.0536 7.000 0.375 Vel = 5.921 8 18.58 1.101 201.000 24.021 to 150 9 36.15 0.2034 201.000 40.885 Vel = 12.182 36.15 64.906 K Factor = 4.49 6 32.05 1.101 50.500 23.646 to 150 10 32.05 0.1628 50.500 8.221 Vel = 10.800 10 1.101 241.000 31.868 to 150 9.528 11 32.05 0.1628 241.000 39.234 Vel = 10.800 32.05 80.630 K Factor = 3.57 9 36.15 1.101 30.500 64.902 to 150 9.528 11 36.15 0.2034 30.500 6.204 Vel = 12.182 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 6 VILLA 4 HEAD CALC. A Date Hyd, Qa Dia. Fitting Pipe Pt Pt Rf. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 11 32.05 1.394 35.000 80.634 to 150 2.382 12 68.20 0.2086 35.000 7.301 Vel = 14.337 12 2.067 2E 5.000 6.500 90.316 to 120 10.000 1.299 13 68.20 0.0463 16.500 0.764 Vel = 6.521 (i'\ 2.0 03 155.000 92.379 g) 150 BKF1 68.20 0.0357 155.000 5.534 Vel = 6.944 • BKF1 2.067 1E 5.000 3.500 97.913 to 120 iT 10.000 15.000 7.000 Fixed loss = 7 BKF2 68.20 0.0463 18.500 0.856 Vel = 6.521 BKF2 1.959 iT 11.635 45.000 105.769 to 150 3E 5.818 30.250 SRC 68.20 0.0398 1G 1.164 75.250 2.993 Vel = 7.259 68.20 108.762 K Factor = 6.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Cn nc) F '~5 - Fire Protection by Computer Design SCHMIDT FIRE PROTECTION 4760 MURPHY CANYON ORAD SAN DIEGO CA 92123 858-279-6122 Job Name : VILLA 1 HEAD CALC. B Building Location System Contract Data File : B-VILLA.WXF Jdm? 4t1_ 44' 1#4 rL Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CHMIDT FIRE PROTECTION 'ILIA 1 HEAD CALC. B City Water Supply: Cl-Static Pressure: 118.86 PSI C2-Residual Pressure: 114.36 PSI C2-Residual Flow: 1257 GPM Page 2 Date Pump Data: 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 10 I - - Di-Elevation: 12.560 PSI D2-System Flow:24 GPM D2-System Pressure: 74.647 PSI Hose ( Adj City ):0 GPM Hose C Demand ) :0 GPM Safety Margin: 44.210 PSI - - - c2 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N ^ 1.85) omputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCH}'IIDT FIRE PROTECTION Page 3 VILLA 1 HEAD CALC. B Date Node Elevation K-Fact Pt Pa Flow Density Area Density NO. Actual Actual Added Actual Deviation 1 29 4.2 32.65 na 24 0.1 240 0 % 3 30.5 42.72 na 5 30.5 43.67 na 6 30.5 44.96 na 8 30.5 45.16 na 6 30.5 44.96 na 10 30.5 46.16 na 9 30.5 51.02 na 11 8.5 61.44 na 12 3 64.88 na 13 0 66.29 na BKF1 0 67.09 na BKF2 0 74.21 na SRC 0 74.65 na The maximum velocity is 12.83 and it occurs in the pipe between nodes 1 and 3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 4 VILLA 1 HEAD CALC. B Date Hyd., Qa Dia. Fitting Pipe Pt Pt Ref± "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 24.00 .874 36.500 32.653 K Factor = 4.2 to 150 -0.650 3 24.00 0.2935 - 36.500 10.713 Vel = 12.834 3 1.101 10.000 42.716 to 150 5 24.00 0.0953 10.000 0.953 Vel = 8.088 5 1.101 13.500 43.669 to 150 6 24.00 0.0953 13.500 1.287 Vel = 8.088 6 -11.35 1.101 7.000 44.956 to 150 8 12.65 0.0291 7.000 0.204 Vel = 4.263 8 1.101 201.000 45.160 to 150 9 12.65 0.0292 201.000 5.860 Vel = 4.263 12.65 51.020 K Factor = 1.77 6 11.35 1.101 50.500 44.956 to 150 10 11.35 0.0239 50.500 1.205 Vel = 3.825 10 1.101 241.000 46.161 to 150 9.528 11 11.35 0.0239 241.000 5.749 Vel = 3.825 11.35 61.438 K Factor = 1.45 9 12.65 1.101 30.500 51.021 to 150 9.528 11 12.65 0.0291 30.500 0.889 Vel = 4.263 11 11.35 1.394 35.000 61.438 to 150 2.382 12 24.00 0.0302 35.000 1.057 Vel = 5.045 12 2.067 2E 5.000 6.500 64.878 to 120 10.000 1.299 13 24.00 0.0067 16.500 0.111 Vel = 2.295 (0 2.003 155.000 66.288 150 BKF1 24.00 0.0052 155.000 0.802 Vel 2.444 BKF1 2.067 1E 5.000 3.500 67.089 to 120 iT 10.000 15.000 7.000 Fixed loss = 7 BKF2 24.00 0.0067 18.500 0.124 Vel = 2.295 BKF2 1.959 iT 11.635 45.000 74.213 to 150 3E 5.818 30.250 SRC 24.00 0.0058 1G 1.164 75.250 0.434 Vel = 2.555 24.00 74.647 K Factor = 2.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design SCHMIDT FIRE PROTECTION 4760 MURPHY CANYON ORAD SAN DIEGO CA 92123 858-279-6122 Job Name : VILLA 1 HEAD CALC. C Building Location System Contract Data File : C-VILLA.WXF a 2 to " s 4 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CHMIDT FIRE PROTECTION Page 2 i. £Jtt .L £iC1-W City Water Supply: Pump Data: Cl-Static Pressure: 118.86 PSI C2-Residual Pressure: 114.36 PSI C2-Residual Flow: 1257 GPM 150 140 130 P 120 R110 - Di-Elevation: 12.560 PSI D2-System Flow:18 GPM D2-System Pressure: 51.103 PSI Hose ( Adj City ) :0 GPM Hose ( Demand ) :0 GPM Safety Margin; 67.755 PSI - = - E 100 S 90 80 U 70 R 60 E -I '2 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85 omputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHMIDT FIRE PROTECTION Page 3 VILLA ,1 HEAD CALC. C Date Node Elevation K-Fact Pt Pn Flow Density Area Density No. Actual ActualAdded Actual Deviation 2 29 4.2 18.37 na 18 0.1 180 0 % 3 30.5 24.01 na 5 30.5 24.57 na 6 30.5 25.33 na 8 30.5 25.44 na 6 30.5 25.33 na 10 30.5 26.03 na 9 30.5 28.89 na 11 8.5 38.94 na 12 3 41.94 na 13 0 43.3 na BKF1 0 43.78 na BKF2 0 50.85 na SRC 0 51.1 na The maximum velocity is 9.63 and it occurs in the pipe between nodes 2 and 3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHI'4IDT FIRE PROTECTION Page 4 VILLA 1 HEAD CALC. C Date - Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 2 18.00 .874 36.500 18.367 K Factor = 4.2 to 150 -0.650 3 18.00 0.1724 36.500 6.292 Vel = 9.626 3 1.101 10.000 24.009 to 150 5 18.00 0.0560 10.000 0.560 Vel = 6.066 5 1.101 13.500 24.569 to 150 6 18.00 0.0560 13.500 0.756 Vel = 6.066 6 -8.51 1.101 7.000 25.325 to 150 8 9.49 0.0171 7.000 0.120 Vel = 3.198 8 1.101 201.000 25.445 to 150 9 9.49 0.0171 201.000 3.444 Vel = 3.198 9.49 28.889 K Factor = 1.77 6 8.51 1.101 50.500 25.325 to 150 10 8.51 0.0140 50.500 0.707 Vel = 2.868 10 1.101 241.000 26.033 to 150 9.528 11 8.51 0.0140 241.000 3.375 Vel = 2.868 8.51 38.936 K Factor = 1.36 9 9.49 1.101 30.500 28.887 to 150 9.528 11 9.49 0.0171 30.500 0.523 Vel = 3.198 11 8.51 1.394 35.000 38.937 to 150 2.382 12 18.00 0.0177 35.000 0.621 Vel = 3.784 12 2.067 2E 5.000 6.500 41.940 to 120 10.000 1.299 13 18.00 0.0039 16.500 0.065 Vel = 1.721 13 2.003 155.000 43.305 150 BKF1 18.00 0.0030 155.000 0.471 Vel = 1.833 BKF1 2.067 1E 5.000 3.500 43.775 to 120 iT 10.000 15.000 7.000 Fixed loss = 7 BKF2 18.00 0.0039 18.500 0.073 Vel = 1.721 BKF2 1.959 iT 11.635 45.000 50.848 to 150 3E 5.818 30.250 SRC 18.00 0.0034 iG 1.164 75.250 0.255 Vel = 1.916 18.00 51.103 K Factor = 2.52 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design SCHMIDT FIRE PROTECTION 4760 MURPHY CANYON ORAD SAN DIEGO CA 92123 858-279-6122 Job Name : VILLA 1 HEAD CALC. D Building Location System Contract Data File : D-VILLA.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CI-IMIDT FIRE PROTECTION Page 2 TTT\ 1 1-T?7Xr ('?T (' fl Date City Water Supply: Pump Data: Cl-Static Pressure: 118.86 PSI C2-Residual Pressure: 114.36 PSI C2-Residual Flow: 1257 GPM 150 140 130 R - Di-Elevation: 12.127 PSI D2-System Flow:18.02 GPM D2-System Pressure: 46.635 PSI Hose ( Adj City ) :0 GPM Hose ( Demand ) :0 GPM Safety Margin: 72.223 PSI - - - P 120 110 S E 100 90 U 80 70 E -a-- R60 50 4 1 40 30 20 10 -- _____ 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) omputerPrograms by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHNIDT FIRE PROTECTION Page 3 VILLA 1 HEAD CALC. D Date ,Node Elevation K-Fact Pt Pa Flow Density Area Press No. Actual Actual Added Req. Req. 4 28 4.2 18.42 na 18.03 .10 180.25 7 5 30.5 20.1 na 6 30.5 20.85 na 8 30.5 20.97 na 6 30.5 20.85 na 10 30.5 21.56 na 9 30.5 24.42 na 11 8.5 34.47 na 12 3 37.47 na 13 0 38.84 na BKF1 0 39.31 na SKF2 0 46.38 na SRC 0 46.63 na The maximum velocity is 9.63 and it occurs in the pipe between nodes 4 and 5 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SCHNIDT FIRE PROTECTION Page 4 VILLA 1 HEAD CALC. D Date Hd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Egv. Ln. Total Pf Pn 4 18.01 .874 16.000 18.418 K Factor = 4.2 to 150 -1.083 5 18.01 0.1726 16.000 2.761 Vel = 9.631 5 1.101 13.500 20.095 to 150 6 18.01 0.0561 13.500 0.757 Vel = 6.069 6 -8.51 1.101 7.000 20.852 to 150 8 9.50 0.0171 7.000 0.120 Vel = 3.201 8 -0.01 1.101 201.000 20.972 to 150 9 9.49 0.0171 201.000 3.444 Vel = 3.198 9.49 24.416 K Factor = 1.92 6 8.52 1.101 50.500 20.852 to 150 10 8.52 0.0140 50.500 0.709 Vel = 2.871 10 -0.01 1.101 241.000 21.561 to 150 9.528 11 8.51 0.0140 241.000 3.375 Vel = 2.868 8.51 34.464 K Factor = 1.45 9 9.50 1.101 30.500 24.416 to 150 9.528 11 9.50 0.0172 30.500 0.524 --Vel = 3.201 11 8.51 1.394 35.000 34.467 to 150 2.382 12 18.01 0.0178 35.000 0.622 Vel = 3.786 12 0.01 2.067 2E 5.000 6.500 37.471 to 120 10.000 1.299 13 18.02 0.0039 16.500 0.065 Vel = 1.723 003 155.000 38.835 150 BKF1 18.02 0.0030 155.000 0.472 Vel = 1.835 BKF1 2.067 15 5.000 3.500 39.307 to 120 IT 10.000 15.000 7.000 Fixed loss 3 7 BKF2 18.02 0.0039 18.500 0.073 Vel = 1.723 BKF2 1.959 IT 11.635 45.000 46.380 to 150 35 5.818 30.250 SRC 18.02 0.0034 1G 1.164 75.250 0.255 Vel = 1.918 18.02 46.635 K Factor = 2.64 Computer Programs by Hydratec Inc. Route lii Windham N.H. USA 03087 II W~. O/2353 - - Fire Protection by Computer Design SCHMIDT FIRE PROTECTION 4760 MURPHY CANYON ORAD SAN DIEGO CA 92123 858-279-6122 Job Name VILLA 1 HEAD CALC. E Building Location System Contract Data File : E-VILLA.WXF 9-1001*0 1 *7 I I:) % -4 0*06- T atkol Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CHMIDT FIRE PROTECTION ILLA 1 HEAD CALC. E City Water Supply: Cl-Static Pressure: 118.86 PSI C2-Residual Pressure: 114.36 PSI C2-Residual Flow: 1257 GPM Page 2 Date Pump Data: • - - Dl-Elevation: 12.560 PSI D2-System Flow:18.02 GPM D2-System Pressure: 57.300 PSI Hose ( Adj City ) :0 GPM Hose ( Demand ) :0 GPM Safety Margin: 61.558 PSI - - - - - p _ - _____ I •....... I I ........ I,,,, _______________ 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85 omputer Programs by H atec Inc. Route ill Windham N.H. USA 03087 SCH?YIIDT FIRE PROTECTION Page 3 VILLA 1 HEAD CALC. E Date Node Elevation K-Fact Pt Pn Flow Density Area Density No. Actual Actual Added Actual Deviation 0.1 180.25 0 % 7 29 4.2 18.42 na 18.03 8 30.5 22.61 na 6 30.5 35.6 na 10 30.5 35.6 na 9 30.5 33.89 na 11 8.5 45.13 na 12 3 48.14 na 13 0 49.5 na BKF1 0 49.97 na BKF2 0 57.05 na SRC 0 57.3 na The maximum velocity is 9.64 and it occurs in the pipe between nodes 7 and 8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 SC}MIDT FIRE PROTECTION Page 4 I7ILLA 1 HEAD CALC. E Date I Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Fe Pv Notes Point Qt Pf/UL Egv. Ln. Total Pf Pn 7 18.02 .874 28.000 18.418 K Factor = 4.2 to 150 -0.650 8 18.02 0.1727 28.000 4.836 Vel = 9.637 8 1.101 201.000 22.608 to 150 9 18.02 0.0561 201.000 11.277 Vel = 6.073 18.02 33.885 K Factor 3.10 6 0 1.101 50.500 35.603 0 to 150 0 10 0 0 50.500 0 0 Vel = 0 10 0 1.101 241.000 35.603 0 to 150 9.528 0 11 0 0 241.000 0 0 Vel = 0 45.131 K Factor = 9 18.02 1.101 30.500 33.891 to 150 9.528 11 18.02 0.0561 30.500 1.711 Vel = 6.073 11 1.394 35.000 45.131 to 150 2.382 12 18.02 0.0178 35.000 0.622 Vel = 3.788 12 2.067 2E 5.000 6.500 48.136 to 120 10.000 1.299 13 18.02 0.0039 16.500 0.065 Vel = 1.723 13 003 155.000 49.500 150 - BKF1 18.02 0.0030 155.000 0.472 Vel = 1.835 BKF1 2.067 1E 5.000 3.500 49.972 . to 120 iT 10.000 15.000 7.000 Fixed loss = 7 BKF2 18.02 0.0039 18.500 0.073 Vel = 1.723 BKF2 1.959 iT 11.635 45.000 57.045 to 150 3E 5.818 30.250 SRC 18.02 0.0034 1G 1.164 75.250 0.255 Vel = 1.918 18.02 57.300 K Factor = 2.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087