Loading...
HomeMy WebLinkAbout7130 KINGFISHER LN; ; FPC2018-0322; PermitPERMIT REPORT Cr 7city of Carlsbad Print Date: 11/03/2021 Permit No: FPC2018-0322 Job Address: 7130 KINGFISHER IN, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2159410400 Track #: Valuation: $107,242.65 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fire Alarm Applied: 09/27/2018 Issued: 11/08/2018 DEV2016-0017 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: Project Title: FOUR SEASONS RESIDENCE CLUB Description: FOUR SEASONS -NEW FIRE ALARM SYSTEM FOR STORAGE BLDG AND RESTROOM BLDG W/ SPORT SUPPLY CLOSET FPContractor: DYNALECTRIC COMPANY - DO NOT USE 9505 CHESAPEAKE DR SAN DIEGO, CA 92123-6393 (858) 712-4750 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov APONEWWWOr- Dynalectric San Diego 9505 Chesapeake Drive San Diego, CA 92123 Phone: 858.712.4700 Fax: 858.712.4701 www.dyna-sd.com Four Seasons Residence Club Fire Alarm Sprinkler Monitoring System Submittal for Approval Revision 000 0 C Prepared September 24, 2018 Dynalectric Job No. 4182173 O(N LOQ o • (N CO uJ Tom 0 N af z 50 C) L1J of 0.. ("1 LU w LI.. N- 9 coQ 0 9 ;a9 1O Ui C Dynalectric Service & Systems Group 9505 Chesapeake Drive San Diego, CA 92123 Phone: 858.712.4700 Fax: 858.712.4797 www.dyna-sd.com Fire Alarm Submittal Table of Contents Mfg. Part# Description CSFM Listing Edwards EST3X (EXISTING) Fire Alarm Control Panel 7165-1657:0306 (EXISTING - FOR REFERENCE ONLY) Edwards SIGA-CT1 /CT2 Input Module, Single/Dual 7300-1657:0121 E STRATEGIC PARTNER California State License No. 749757 An EMCOR Company EDV/ARLJS Catalog P Mid-Sized Systems LIFE SAFETY NCIDE-Nf MANAGEMENT EST3X Life Safety Control System (EXISTING - FOR REFRENCE ONLY) FDNY COA 6087 a 7165-1657: 0186/0306 S3000 Description EST3X represents the latest generation of life safety control panels for mid to large sized applications. With large multi-message dis- plays and innovative controls, intuitive interfaces, and bold colored cabinets - these systems capture the imagination, and catch the eye. But behind the LCD display is where they really shine. New microprocessors and chipsets take full advantage of the lat- est advances in computing technology, leading to smarter, faster, higher-capacity processing and more efficient designs. EST3X's patented Voltage Boost' technology, for example, delivers consis- tent voltage - even at low battery power - resulting in lighter cable requirements and/or longer runs. That saves time and money. Meanwhile, advanced communications provide integrated IP com- munications via existing Ethernet networks directly to subscribed central stations. Email and text messaging options enrich this advanced communication environment with instant notification - anywhere, any time. High performance processing also leads to powerful networking features and versatile digital audio functionality. The wide range of EST3X configurations include standalone operation, networking with up to 64 nodes, or integration with an EST3 network com- prising as many as 64 nodes - complete with mass notification capabilities and display of security events. EST3X sets a new standard in front-panel life safety control interfaces. Its exclusive SpeedTouch rotary control offers nimble forward and back scrolling through events and options, while a mere tap of the control selects items with a clean fluidity of motion Its extra-large backlit display reveals up to eight concurrent mes- sages, and switch/LED strips provide ample space for meaningful custom labels. And for end users, large tactile control buttons instill confidence and promote quick response when time is of the essence. Pagel 0110 Standard Features Up to six intelligent analog loops hosting as many as 1,500 Signature Series devices per panel Optional integrated eight-channel digital audio 10 amp power supply with universal 94 to 264 Vac input voltage Patented Voltage Boost' technology delivers consistent volt- age - even at low battery power Four built-in 3-amp notification/auxiliary circuits Large 24-line by 40-character backlit LCD Simplified operation with the SpeedTouch" rotary control 65 amp hour battery charger 64-node network nodes using copper and/or fiber Supports up to 30 R-Series remote annunciators Part of an end-to-end audio solution suitable for low frequency signaling in sleeping areas Space for up to three additional option cards such as extra SLC loops, amplifiers, or dialer/modem Optional Ethernet Interfaces for central station communication, email, and diagnostics 1,100 event history log Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 UL2572 Listed for Mass Notification, UL864 UUKL Listed for Smoke Control, UL864 Listed for releasing applications using SIGA-REL DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 I I I I I I I I I I I I I I I I I I I Application Application flexibility is where EST3X's computing power is put to best use. This generation of control panels is equally at home as the center of a simple single-building standalone system as it is when part of a sophisticated life safety network serving thousands of points across multiple buildings. Optional voice evacuation bridges the gap left by other mid-range systems, and makes these panels a cost-effective solution for most applications. Strong Networking Networking is among EST3X's strong suits. Highly efficient RS485 connectivity, plus fiber-optic communications deliver faster re- sponse times and more sophisticated diagnostic capabilities, while cost-effective remote annunciation solutions keep basic monitor- ing and control always within reach. A simple EST3X network can comprise up to 64 nodes - enough to serve the needs of most campuses and larger buildings. Its ability to join an EST3 network with as many as 64 nodes extends EST3X's reach into mass notification applications, security report- ing, as well as making it an ideal candidate for retrofits. High Capacity Audio EST3X features a full eight channels of integrated digital audio with up to two min- utes of on-board programmable message storage. An optional high quality paging microphone gives live access to local, as 10 An optional paging microphone well as remote, audio functions. Auxiliary provides iocaas well as inputs are available for mass notification remote, audio functions. operations, and ZA Series amplifiers may be mounted directly on the EST3X rail assembly. High Fidelity Audio Approved for Sleeping Areas EST3X is part of an end-to-end low frequency/high fidelity solu- tion listed to UL 464 and UL 864. Its audio system approved for code-compliant 520 Hz signaling in sleeping areas when used in conjunction with: a factory-supplied 520 Hz audio file one or more of the following amplifiers: 3-ZA20A, 3-ZA20B, 3-ZA40A, 3-ZA40B, 3-ZA95, SlGA-AA30, SlGA-AA50, 1133- 125, or 1B3-250 one or more Genesis High Fidelity speakers (G4HF or GCHF series) Consult the EST3X Compatibility List for details. Seamless System Integration EST3X borrows much from it's larger sibling, the venerable EST3 Life Safety Platform. And for good reason: by integrating with the EST3 networking and computing environment, an EST3X control panel can serve as a cost-effective remote node for extinguishing, smoke control, or even mass notification functions - all within the same compliance framework. Retrofits and expansions benefit enormously from this arrange- ment, but programming and equipment management for new in- stallations is equally efficient as a result of these shared resources. EST3X will accommodate up to three EST3 modules on its own rail assembly, giving it access to such proven EST3 successes as zoned amplifiers, conventional device circuits, modem communi- cators, and RS-485 functions. Meanwhile, installers familiar with EST3 configuration will find that the two systems share many of the same programming and diagnostic conventions. Page 2 of 10 Local and Remote Annunciation - Up to 30 R-Series LCD, LED annun- ciators and driver interlace cards may be configured for each node on the EST3X network. No additional nodes are required for annunciation purposes. In -. addition, EST3X supports EST3 network - annunciators, while GCI and GCIX driver Up to 30 R-Series annunciators interface cards provide cost-effective may be configured for each graphic annunciation solutions. And all node on the EST3X network. annunciator inputs and outputs are easily programmable through the rules and labels function of EST3X's Software Definition Utility. Power to Count On EDWARDS' patented Voltage BoostTM technology delivers a con- sistent 22.5 Vdc - even at low battery power. This means lighter gauge cable can be used for equivalent distances compared with conventional power supplies, or longer wire runs on the same gauge cable. Either way, this breakthrough technology saves time and equipment costs, making EST3X not only a high-performance solution - but a cost-effective one as well. EST3X's four on-board Notification Appliance Circuits are fully syn- chronized to UL 1971 standards - without the need for external modules or other electronics. It's ample 10-amp power supply is finely tuned to get the most out of EDWARDS' widely-acclaimed low profile Genesis notification appliances. Dimensions The backbox is designed for semiflush or surface mounting. Con- duit and nail knockouts, keyhole style mounting holes, and wide wiring troughs facilitate efficiency during installation. R8L9 ,n (cm) 66 4.82 Top view 21.72 (55.17) i48 - - 14 - -1 0 1 I.. .1 c2) 0 eackbox 35A7 (90.09) 84 3) -o 73) Side view Side view I. Bottom view Note: Add 0.25 in (0.64 cm). to height and width dimensions to allow for knockouts when framing in the backbox for semiflush mounting. DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 8.0 (20. 10. (27. 8.1 (20. 5.0 (12. 0) .2 00 (5.08) 2.16 (5.49) Four 3-amp Class B NACs. Four Class A NACs with CLA-PSIO. NAC 1 1 NAC 2 NAC 3 NAC 41 + Up to three EST3 Local Rail Modules including: Signature Series Drivers Zoned Amplifiers e Modem Communicators Network Short Haul Modems Fiber Optic Communications Interfaces Hardwired Initiating Device Modules Up to three Control/Display Modules 3X-NET8, 3X-FlB8 H'1 I Upto30 Class B Annunciators. 4,000 ft. max. LgL 3X-NET 3X-FIB . Ono= it 9 EST3 Network... up to i- 64 nodes Or.,. UL Used Signaling UL Listed Life Safety Detection * — UL Listed Security UL Listed Mass Notification Relays: 3 Form C Aux. Power: 24 VDC. 1.0 A total EST3X Network... up to eight nodes UL Listed Signaling UL Listed Life Safety Detected I St-Si -UPU Must SOSfO To next L network Class A only node Network data circuit, Class B audio Io er esor,se 5FS1 -CPU Main Board To next network 3-Asu/3x-PMI node Primary Audio Data Network data circuit, Class A audio taec (t er ene nn,r • om MINE, SEEMS I & To next network node I System Layout Wiring Up to six intelligent analog loops hosting as many as 250 devices each. 7Standad SLC2 SLC3 1 SLC4 SLC5 1 SLC6 3-SDC1 3-SDDC1 3-SDDC (' (occupies one (occupies one LRM expansion slot) LRM expansion slot) I I 6311 © © 7 Fire Works Ethernet U Signature (initiating) Data Circuit To two-wire smoke detector Auxiliary power, +24 V Auxiliary power, common If shielding is used, it must be continuous 9J and free from earth ground. A AifO PIL 5 2arC LOO user u.m All wiring is power limited. SFS1-CPU Main Board O Notification Appliance Circuits PSi O-4B Power supply Normal - + - + - + - + EOL Active ! ! ! resistor Wiring is supervised and power limited. T82 terminal marking indicates signal polarity when the circuit is active. Polarity reverses when the circuit is active. For proper circuit supervision, break the wire run at each notification appliance and install the EOL resistor at the end of the circuit. Do not loop wires around notification appliance terminals. U Network data circuit I'I'L'L"k'!flJrIi I Page 3of 10 DATA SHEET E850050133 Not to be used for installation purposes. Issue I Main Component Assembly I EST3X systems are designed for quick assembly and easy access in the field. Components are modular and require no special tools to service or replace. The 3-SFS1 Electronics Chassis provides the mounting, internal power, and data distribution for the SFS1 -CPU main board and up to three local rail modules. It installs over the PSi 0-413 Power :Supply. The SFS1 -CPU main board mounts to the Electronics Chassis. Common Relay flutputs Signaling Network, J'SFSl -cpu annunciator, Main Board RS-232 circuits SLC2 Signaling line circuit The 4X-LCD as- sembly mounts to hinge pins on the CPU and connects with a single ribbon cable. 4X-LCD User Interface I I I I I I I I I I I I I I I I Two cables connect the PS10-413 Power Supply to the back of the SFS1 - CPU main board. SFS1-CPU Main Board SFS1 -CPU Main Board The SFS1 -CPU main board processes all infor- mation from modules installed within the cabinet as well as data received from other panels over the network data riser. When a network card is installed, the CPU employs a command set to determine its type. ,. SFS1 -CPU Specifications Voltage 24 VDC Current Standby 115 mA at 24 VDC Alarm 115mAat24VDC Relay outputs Quantity 3 (alarm, supervisory, and trouble) UL type Common Contact arrangement Form C 30 VDC at 1 A resistive AUX power outputs Quantity 2 Voltage 24 VDC, resettable or continuous Current 1.0 A each circuit, 1.0 A total Data network (RS-485) Nodes 2 to 64 (requires optional network card) Performance class. Class A or Class B Wire type Twisted pair, 6 twists per foot, mm. Circuit length 5,000 ft. (1,524 m) between any three panels Circuit resistance 90 0, max. Circuit capacitance 0.3 pF, max. Serial Port (RS-232) The on-board serial port supports communication to the Fire Works graphical users interface or the FSB-PC series of protocols converters for ancillary communications to BMS systems. Circuit length 20 ft. (6 m) max. Circuit resistance 13 0, max. Circuit capacitance 0.7 i.iF, max. Annunciator port (RS-485) Performance class Class B and Redundant Class B Baud rate 9600 and 38400 Wire type Twisted pair, 6 twists per foot, mm. Circuit length 4,000 ft. (1,219 m) Circuit resistance 90 0, max. Circuit capacitance 0.3 pF, max. Signaling line circuit Quantity 2 (second SLC requires optional 3-SDC1 card) Performance class Class A or Class B Circuit capacity 125 detectors, 125 single address modules Circuit resistance 100 0, max. Circuit capacitance 0.5 pF, max. Wire size 18 to 12 AWG (0.75 mm2 to 2.50 mm2) Ground fault 10 k0 impedance Operating environment Temperature 32 to 120°F (0 to 49°C) Relative humidity 0 to 93% noncondensing Notes For battery calculations, standby and alarm currents include all listed primary power supplies. The common trouble relay operation does not include AC trouble delay functionality and cannot be used for reporting troubles off premises per UL 864 9th edition. Page 4of 10 DATA SHEET E850050133 Not to be used for installation purposes. Issue 1 Wiring Mains input2 Supervised, non power-limited Battery input Supervised, non power-limited NAC outputs Supervised, power-limited Wire size 18 to 12 AWG (0.75 mm2 to 2.50 mm2) Ground fault impedance 10 kO Operating environment I Battery charging capacity 65 Ah max. Total Power Voltage 24vdc Standby Current 88mA Alarm Current 169mA Supply Ratings Current 10 amps (UL), 9.0amps (ULC) PSi O-4B Power I Supply Card The PSi 0-413 Power Supply Card provides the required power and related supervision functions I for the control panel, as well as filtered, regulated power to the rail chassis modules. It also provides 24 VDC for operating ancillary equipment. PSi O-4B Specifications Mains voltage 94 to 264 VAC, 50/60 Hz AC Input Current Standby 1.5 amps Alarm 3.0 amps Brownout level 93 VRMS Notification appliance/Auxiliary power circuits UL rating Quantity 4 Circuit configuration Class B1 Output voltage Special: 24 Vdc Regulated: 24 Vdc Output current Special: 3 amps Regulated: 1.5 amps EOLR 15 k) (UL P/N EOL-15, ULC P/N EOL-P1) Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing 'Class A when a cLA-pslo class A adapter card is installed. 2 Connect the mains supply using a dedicated branch. 3-SDC1 Signature Standard Data Circuit Card SDC1 card for SLC1 S. Each 3-SDC1 Signature Data Optional Circuit Card provides one Class SDC1 card A or Class B signaling line circuit for 51.02 'tev, Ir (SLC1) that supports up to 125 SFS1'P1 Signature Series detectors and CID 125 Signature Series module MainZard addresses. These modules also provide connection for powering conventional two-wire smoke detector circuits on Signature Series modules. EST3X comes standard with one 3-SDC1 card installed as SLC1. An optional second 3-SDC1 card may be installed to provide SLC2, thus doubling system signaling line capacity. 3-SDC1 Specifications Voltage 24 VDC Operating current with fully loaded loop Standby 3-SSDC1 144 mA; 3-SDDC1 264 mA Alarm 3-SSDC1 204 mA; 3-SDDC1 336 mA Smoke power 19.95 VDC max.' Circuit Configuration Class B, Style 4, DCLB; Class A, Style 6, DCLA Capacity 125 Signature Series detectors and 125 Signature Series modules per SLC Resistance 100 0 with 250 devices Capacitance 0.5 jjF max. Wire size 12 AWG (1.5 mm2) max. Termination Removable plug-in terminal strips on the SFS1 -CPU main board and Signature module Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing 'For special applications, refer to EST3 ULVULC Compatibility usts (P/N 3100427) I I 4X-LCD User Interface Included in the EST3X basic package, the 4X- LCD provides the user interface for the EST3X system. It connects to the SFS1 -CPU main board with a ribbon cable, and attaches to the CPU via hinges. Only one display module is required to provide a point of control for the entire network. Additional displays can be added to any EST3X panel in the network to provide additional points of control. 4X-LCD Specifications Operating current Standby 55mA Alarm 66mA LCD display Backlit liquid crystal display 240 x 320 pixels 24 lines of 40 characters Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing SFS1 LED Control! Display Module LED Rail The SFS1 LED Control/Display Module Control/ Module provides additional operator interface Display capability for the SFS1 system. It can Module be mounted on any of the three right- most local rail modules on the 3-SFS1 electronics chassis. Inserts are provided for labeling switches and LEDs. SFS1 Specifications Voltage 24 VDC Operating current Standby 2.0 mA plus 1.5 mA for each active LED Alarm 2.0 mA plus 1.5 mA for each active LED Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing Page 5of 10 DATA SHEET E850050133 Not to be used for installation purposes. Issue 1 I 3X-FIB fiber optic 1SFS1-CPU network module ?il . "9 Main Board The 3X-FIB fiber optic network mod- ule gives an EST3X panel the ability to network 64 EST3X panels, or interface 3X-FIB8 Class B connections are supported. The with an EST3 network. Both Class A and module consists of the adapter card and adapter electronics card. card The 3X-FIB supports the following fiber optic transceivers: Model Description SMXL02 Standard output single mode fiber optic transceiver 5MXH12 High output single mode fiber optic transceiver MMXVR Standard output multimode fiber optic transceiver The 3X-FIB provides terminals for connecting a 24 VDC backup power source to maintain data transmissions in the event the panel is powered down. Note: All networked panels must have the 3X-FIB network card installed. 3X-FIB Specifications Voltage 19.2 to 27.6 VDC (24 VDC nominal) Fiber optics network and audio Budget SMXL02 15 dBm between two interfaces SMXHI2 25 dBm max. and 8 dBm mm. 10 dBm between two interfaces MMXVR 50/125, 62.5/125, or 100/140 for MMXVR Cable type Connectors 50/125, 62.5/125, or 100/140 for SMXLO2, SMXHI2 Type Duplex SC MMXVR Type ST Network data circuit Circuit configuration Class B (style 4) or Class A (style 7) Data rate 19.2 K, 38.4 kbps Isolation Isolated from previous panel CPU when using copper. Total isolation when using fiber optics. Digitized audio data circuit Circuit configuration Class B (style 4) or Class A (style 7) Data rate 327 kbps Isolation Isolated from previous panel CPU when using copper. Total isolation when using fiber optics. Copper wired network data circuit segment Circuit Length 5,000 ft. (1,524 m) max. between any three panels Resistance 90 0 max. Capacitance 0.3 lJF max.' Wire type Twisted Pair, 18 AWG (0.75 mm2) mm. Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing include shield capacitance, if shielding is used I I I Page 6 of 10 3X-F1B8 fiber optic sFs1-cPu network module r'"I fI. Main Board The 3X-FIB8 fiber optic network mod- r ule gives an EST3X panel the ability to network up to eight EST3X nodes. Both Class A and Class B connections are supported. The module consists of the 3x-FIB adapter card and electronics card. The 3-F1B8 supports the following fiber adapter card optic transceivers: Model Description SMXL02 Standard output single mode fiber optic transceiver 5MXH12 High output single mode fiber optic transceiver MMXVR Standard output multimode fiber optic transceiver The 3X-F1B8 provides terminals for connecting a 24 VDC backup power source to maintain data transmissions in the event the panel is powered down. Note: All networked panels must have the 3X-F1B8 network card installed. 3X-FIB8 Specifications Voltage 19.2 to 27.6 VDC (24 VDC nominal) Fiber optics network and audio Budget SMXL02 15 dBm between two interfaces SMXHI2 25 dBm max. and 8 dBm mm. 10 dBm between two interfaces MMXVR 50/125, 62.5/125, or 100/140 for MMXVR Cable type Connectors 50/125, 62.5/125, or 100/140 for SMXL02, SMXH12 Type Duplex SC MMXVR Type ST Network data circuit Circuit configuration Class B (style 4) or Class A (style 7) Data rate 19.2 K, 38.4 kbps Isolation Isolated from previous panel CPU when using copper. Total isolation when using fiber optics. Digitized audio data circuit Circuit configuration Class B (style 4) or Class A (style 7) Data rate 327 kbps Isolation Isolated from previous panel CPU when using copper. Total isolation when using fiber optics. Copper wired network data circuit segment Circuit Length 5,000 ft. (1,524 m) max. between any three panels Resistance 90 0 max. Capacitance 0.3 pF max.' Wire type Twisted Pair, 18 AWG (0.75 mm2) mm. Copper wired audio data circuit Circuit Length 5,000 ft. (1,524 m) max. between any three panels Resistance 90 0 max. Capacitance 0.09 pE, max' Wire type Twisted pair, 18 AWG (0.75 mm2) mm. Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing 'Include shield capacitance, if shielding is used. DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 I 3X-NET Network I Adapter Card The 3X-NET network adapter card gives an SFS1 -CPU main board the ability to network up to 64 nodes on an EST3 I network. The card supports Class B and Class A wiring. The 3X-NET adapter card provides two 1i independent RS 485 circuits: one for network data communica- tions and one for digital audio communications. 3X-NET Specifications Voltage 24 VDC Operating Current Standby 98 mA at 24 VDC Alarm 98 mA at 24 VDC Circuit configuration Network data Class A, Style 6 & Class B, Style 4 Network audio Class A, Style 6 & Class B, Style 4 Isolation Network data Network A port not isolated; Network B port isolated Network audio Audio A IN and Audio B IN isolated Audio A OUT and Audio B OUT not isolated Wire size Twisted pair' 18 AWG (0.75 mm) min. Circuit length 5,000 ft. (1,524 m) between any three panels Circuit resistance 90 0 max. Circuit capacitance Data: 0.3 pF max.; Audio 0.09 pF max. Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing 'Six twists per foot minimum 3X-NET8 ) SFS1-CPU network card Main Board The 3X-NET8 RS-485 network card gives an SFS1 -CPU main board the ability to network through dedicated copper wire up to eight EST3X control panels. The card supports Class B and - 3X-NET Class A wiring. card Note: All networked panels must have a 3X-NET8 network card installed. 3X-NET8 Specifications Voltage 24 VDC Operating Current Standby 98 mA at 24 VDC Alarm 98 mA at 24 VDC Circuit configuration Network data Class A, Style 6 & Class B, Style 4 Isolation Network data Network A port not isolated, Network B port isolated Wire size Twisted pair' 18 AWG (0.75 mm) mm. Circuit length 5,000 ft. (1,524 m) between any three panels Circuit resistance 90 0 max. Circuit 0.3 pF max. capacitance Operating environment 32t0 120 °F (0 to 49 °C) Temperature 0 to 93% noncondensing Relative humidity 1 Six twists per foot mm 3X-ETH Ethernet Adapter Cards SFS1 -CPU 0i r 1 Main Board Three optional Ethernet adapter cards are available for EST3X applications. Each of these provide specific features such as panel programming, diagnostics, and status monitoring, as well as central station connectivity, and email or email- card to-text messaging capability. Supported communications ETHI ETH2 ETH3 Cu communications with the Panel for Programming and Diagnostic Functions FireWorks (ECP/IP) Gateway Communications • • IF Dialer Communications Email and Text Communications Each EST3X control panel supports up to eight IP services, which can provide con- nection to any combination of the following functions: Programming FireWorks Graphical User Interfaces IF Dialer (IP-DACT) Email Each EST3X network supports up to: 10 ECP Connections, and; 100 Dialer Accounts, and; 100 Email Accounts (up to 20 email addresses er account). 3X-ETHI, 3X-ETH2, 3X-ETH3 Specifications See Ordering Information for adapter card functional descriptions Ethernet 10/100 Base-T Voltace 24 VDC Operating current Standby 42 mA at 24 VDC Active 42 mA at 24 VDC Connection mode Auto negotiation Wire runs Distance 200 ft. (60 m) max.' Type Cat 5 Connector RJ-45 Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing 'Panel to communication equipment I Page 7 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 I I I I I I I I I I I I I I I I I I I 3X-PMI Paging Microphone Interface The 3X-PMl Paging Microphone Interface provides controls for emergency voice/alarm communica- tions. It consists of an audio mount- ing bracket, EAEC Emergency Audio Evacuation Controller card, audio enclosure, and paging microphone. 3X-PMI Paging Microphone Interface Specifications Voltage 24 VDC Current Standby 23mA Alarm 29mA Ground fault impedance 10 ko Wire size 18 to 12 AWG (0.75 to 2.50 mm2) Audio channels 8 simultaneous Audio inputs Local microphone Isolated and supervised Remote microphone Isolated and supervised Remote audio Isolated and supervised EAEC communication See the EAEC Emergency Audio Evacuation Control Installation Sheet (P/N 3101789) Messages Storage 2 mm. total Length 39 sec. max. Controls and indicators Common Paging Volume Indicates relative signal strength during active page Ready To Page Flashes during preannouncement Paging Microphone tone, steady when ready to page All Call Activates/deactivates page to all areas All Call Minus Activates/deactivates page to areas not receiving EVAC or Alert message Page To Evac Activates/deactivates page to areas currently receiving the EVAC message Page To Alert Activates/deactivates page to areas currently receiving the Alert message Operating environment Temperature 32 to 120°F (0 to 49°C) Relative humidity 0 to 93% noncondensing SFs1•cpu I tt0It 01 t?°j.t I°tI°i'I Network I I Network option card option card installed not installed KEY OUT Remote AUDIO—OUT microphone SHIELD MN-PASM2 1 UL 864 and I UL 2572 listed MN-FVPN J equipment with compatible ratings Page 8 of 10 CLA- PSi 0 Class A PS1O-4B Adapter Card Power The CLA-PS10 Class A Adapter Card is I supply IO an optional card used to convert the four Class B notification appliance/auxiliary power circuits on the power supply card to Class A. cLA-Pslo class A CLA-PSIO Specifications Adapter card Voltage 24 VDC Notification appliance/Auxiliary power circuits UL rating Special application or Regulated Quantity 4 Performance class Class A Output current Special 3.0 A Regulated: 1.5 A each circuit EOLR 15 IcC (UL P/N EOL-1 5, ULC P/N EOL-131) Wiring Supervised, power-limited Wire size 18 to 12 AWG (0.75 mm2 to 2.50 mm2) Operating environment Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing DATA SHEET E85005-0133 Not to be used for installation purposes. issue 1 Ordering Information Intelligent Analog Control Panels Model I Door Color Language Description 3X-SFS1 B Bronze FACP, complete system with user interface, CPU, one loop with second loop expansion, three option card > 3X-SFS1 R English Red slots, four Class B NAC, universal 110/220v 10 amp power supply. Order 3-SDC1 for second loop. 3X-SFS1Bi Bronze 3X-SFS1 Ri I Selectable Red 1R1M6 Flush trim ring communication option cards I Network 3X-NET8 RS485, eight node max. Class NB network. Use on 3-SFS systems only. 3X-NET RS485, Class NB network. For connection with node counts above eight or to EST3 systems. 3X-F1B8 Fiber, 8 node max. Uses MMXVR, 5MXH12, SMXL02. Use on 3-SFS systems only. 3X-FIB I Fiber motherboard for connection to EST3 systems. Used with MMXVR, SMXHI2 and SMXL02. SMXL02 Standard output single mode fiber optic transceiver 5MXH12 High output single mode fiber optic transceiver MMXVR Standard output multimode fiber optic transceiver I Communication Options (See 3X-ETH installation sheet P/N 3101794-EN for details on wiring specific applications.) 3X-ETH1 Ethernet Adapter, 10/100. Provides Ethernet connection from system to 3-SDU for remote programming and diagnostics, and to FireWorks computer graphics workstation. 3X-ETH2 I Ethernet Adapter, 10/100. Provides the functions of ETH1 plus IF for central station communications. 3X-ErH3 Ethernet adapter card. Provides the functions of the 3X-ETH2 plus the added capability of sending email messages as well as SMS text messages by means of email-to-text. I Front Panel LED/Switch display modules 4X-1 2/Si GY LED Display/Control Module - 12 Switches, 1 Green, 1 YELLOW LED per switch. 4X-1 2/Si RY LED Display/Control Module - 12 Switches, 1 RED, 1 YELLOW LED per switch. 4X-1 2SR LED Display/Control Module - 12 Switches with 12 RED LEDs. 4X-1 2RY LED Display Module - 12 pairs of LEDs (1 Red; 1 Yellow) 4X-24Y LED Display Module - 24 YELLOW 4X-24R LED Display Module - 24 RED 4X-6/3S1 G2Y LED/Switch Module - six groups of three Switches with one LED each. 4X-6/3S1 GYR LED/Switch Module - six groups of three Switches with one LED each. 4X-4/3SGWVR LED/Switch Module, four groups of three switches and four LEDs. LED colors: Green, Red, Yellow and White. 4X-LKF Label Kit, French Option Cards and Interfaces 3X-PM1 Paging Microphone Interface 3-SSDC1 Single Signature Driver Controller, c/w one 3-SDC1 3-SDDC1 Dual Signature Driver Controller, c/w two 3-SDC1 s 3-SDC1 Signature Device Card - expands the 3X base panel to two loops 3-SDC1 -HC 3-SDC1 -HC used with circuits that contain more than 90 isolators. 3-ZA20A 20 Watt Zoned Amplifier w/Class NB Audio & Class NB 24 VDC outputs 3-ZA20B 20 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs 3-ZA40A 40 Watt Zoned Amplifier w/Class NB Audio & Class NB 24 VDC outputs 3-ZA40B 40 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs 3-MODCOM Modem/Dialer (DACT) 3-MDC1 Addressable Analog Module 3-1DC8/4 Initiating Device Circuit Module 3-LDSM LED Display Support Module. Provides interface for one LED/Switch display module. Mounts in an option card slot where no Option cards are installed. 3-OPS Off Premises Signaling module CLA-PSi 0 Class A Adapter, PSi 0 NACs CDR-3 PSNl Coder Module GCI Graphic Annunciator Driver Master, provides outputs for 32 LEDs and connection to common control switches and LEDs for R-Series annunciators. GCIX Graphic Annunciator Driver Expander, provides outputs for 48 LEDs and inputs for 24 switches. I I [1 Page 90110 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 Accessories PSi O-4B Power Supply, Replacement SFS1 -ELEC Base Electronics, replacement 4X-LCD Main user interface assembly, monochrome. Eight line 1/4 VGA LCD, four controls plus rotary knob. English language. 4X-LCD-LC Main user interface assembly, monochrome. Eight Line 1/4 VGA LCD, four controls plus Rotary knob. Insertable language, shipped with English inserts. Order alternate languages separately. 4X-DR Blank hinged local rail module door 4X-CAB6D Replacement door, bronze 4X-CAB6DR Replacement door, red CAB6B Backbox, black CAB6BEQ Seismic hardening Kit for batteries up to 17Ah. Note: For earthquake anchorage, including detailed mounting weights and center of gravity detail, please refer to Seismic Application Guide 3101676-EN. Approval of panel anchorage to site structure may require local AHJ, structural, or civil engineer review. LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 10 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r1i77 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0306 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: EST/Edwards Brand 3X-SFSI B(i) and 3X5FS1 R(i) Fire alarm control systems. Automatic, manual, coded, noncoded, local, auxiliary , remote station , (DACT), (reverse polarity), proprietary (multiplex), central station, waterfiow, sprinkler supervisory service and releasing device. Model EST3X is also suitable for mass notification system and smoke control. Refer to listee's data sheet for additional detailed product description and operational considerations. System subassemblies: 3X-PMl, 4X-12/Si GY, 4X-12/Si RY, 4X-1 2SR, 4X-24R, 4X-6/3S1 G2Y, 4X-6/3SlGYR, 4X-4/3SGYWR, 4X-DR, 4X-LRMF, SFSi-CPU, 4X-LCD(-LC)3X-ETHI, 3X-FlB8, 3X-NET8, 3X-NET SFSI(i)-ELEC, CLA-PSIO, PSI0-413, 4X-CAB6DR, 4X-CAB6D, CAB613 Components: 3-SDC, 3-SDC1, *3..SDC1..HC: Signature Data Card 3-CCI: City Module URSM: Universal Riser Supervisory Module RMi: Supervisory Module MN-COMlS, 3-FlBMNB2, MN-ABPM, 3-ATPINT, ATPC: Interface Modules PTi-S: System Printer PTi-P: System Printer Paralle 3-NSHM1, 3-NSHM2: Modem Communication Cards MN-NETSW1: Network Switching Hub MN-PASM: Audio Preamp Module MN-FVPN: VoIP Encoding/Decoding Unit SMXL02, SMXHI2, SMXXLO, SMXHI, MMXVR: Fiber Transceiver 3X-PMl: Paging Microphone Interface 3-SSDC1, 3-SDDC1: Single Signature Drive Controllers 3-ZA20A, 3-ZA2013, 3-ZA40A, 3-ZA40B: Amplifiers 3-MODCOM, 3-MODCOMP: Modem Dialers 3-AADC1: Addressable Analog Module 3-IDC 8/4: Initiating Device Circuit Module CDR-3: PSNI Coder Module 3-OPS: Off Premise Signaling Module *3x..ETHI *3XETH2, *3XETH3: Ethernet Adapter Rev. 11-28-17jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 I Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0306 Page 2 of 2 RATING: 120 VAC 50/60HZ, 240 VAC 50/60HZ, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Suitable for high-rise applications. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 edition and UL Standard 864 9th edition. Refer to manufacturer's Installation Manual for details. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Alarm Verification shall not be implemented on initiation-device circuits that have the option of releasing and extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. *Rev. 11-28-17jp T1 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SEA I FAILMI L"l. Un d Tec nolog u EDWARDS Catalog Intelligent Input-Output LIFE SAFETY T INCIDENT MANAGEMENT Input Modules SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 I I I Overview SIGA-MCT2 Standard Features J I U1 '. ¶Yf flhilT II L • • 4444 - SIGA-CTI/2 MEA 7300-1657: 0121 83424 The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personal- ity code' selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CTIHT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 "F to 158 "F (0 "C to 70 "C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UlO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four 'personality codes" to be downloaded to the mod- ule through the loop controller. SIGA-CTI HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. I Installation SIGA-CTI, SIGA-CTI HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) Status LED viewing ports II • II SIGA-MCT2: mount the UlO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SlGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UlO Motherboard 6-32 Sell-tapping screws C Plug n OCaPhve Module screws #6 Flat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SlGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. I Page 2of4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1pF per Circuit For Design Reference: Wire Size I Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) 4,000 ft (1,219 m) Typical N.O. Initiating Device A AAStyle B (Class B) TB2 Red LED (Alarm/Active) TB1 f DATA IN (+)> DATA OUT (+) DATA IN (-) > . DATA OUT C-) From Signature Controller Y To Next Device or Previous Device SIGA-CT1, SIGA-CT1 HT Typical N.C. Initiating Device INPUT 1 'C X Style B (Class B) UL/ULC Listed 47 EOL l Red LED (Alarm/Active) TB1 f DATA B'i(+)>—._ DATA IN C-)> From Signature Controller or Previous Device A SIGA-CT2 UL/ULC Listed . . S 471(0 EOL Green LED (Normal) DATA OUT DATA To Next Device INPUT UL/ULC Listed 471(0 EOL Green LED (Normal) Typical NO Initiating Device ,J, ,j, NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to signature controller installation sheet for wiring specifications. Maximum 10 Vdc@350 pA The SIGA-UI06R and the SIGA-ul02R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. ullsjLc Iiled 47N 501. :: ure Data IL Data Out Groan LED (Normal) Red LED thotivol UL/ULC L,eood 5 711W (01 MCTS u101RlsenIeo motherboard l o connections oniumpe, Sottings 1requirnd to, MCr2. SlGA-MCT2 Page 3of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CTI HT I SIGA-CTI SIGA-CT2 I SlGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pAT Activated = 680pA' Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates UI02R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) to ° Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled: On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog Description Number Ship Wt. lbs (ku) SIGA-CT1HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) > SIGA-CT2 Dual Input Module - UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs 032 015 - Two Module Positions SIGA-UI06R Universal Input-Output Module Board w/Riser Inputs 0 62 0 28 - Six Module Positions SIGA-UI06 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0 (3.1) Mounting Plates SIGAMB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES I LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 I Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CTI, SIGA-CTI HI, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI, SlGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, I SIGA-MCCI, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SlGA-MB4, SIGA-MPI, SIGA-MP2 and SIGA-MP2L mounting plates. I Models SIGA-U102R, SlGA-U106 and SIGA-U106R motherboards. Model CS-SIGA-CCIP releasing module. Models SIGA-CCIS and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model I SIGA-CTI HI; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational I consideration. RATING: 15.2 - 19.95 VDC I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. I NOTE: Formerly 7300-1591:121 and 7300-1388:178 I *Rev 01-11-16 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 I Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division