HomeMy WebLinkAbout2530 EL CAMINO REAL; 507; FA160013; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160013 2530 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1670305000 Lot #: 0 Reference No.: FIJ Status: ISSUED Applied 3/10/2016 Approved: 3/10/2016 Issued: 3/10/2016 Inspector: Project Title: SDCCU #507 REPLACE EXISTING FACU, KEYPAD, AND COMMUNICATOR WITH NEW EQUIPMENT. RECONNECT AND MONITOR ALL OHTER EXISTING DEVICES. THIS DEDICATED FUNCTION FIRE ALARM CONTROL UNIT WILL REPORT TO A CENTRAL STATION. GSM UNIVERAL WIRELESS ALARM COMMUNICATOR. Applicant: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Owner: VONS COMPANIES INC A A E PACIFIC PARK ASSCS C/O HUGHES INVESTMENTS-MANAGER P0 BOX 8700 NEWPORT BEACH CA Fees ($) Add'l Fees ($) I Total ($) Balance ($) 452 0 452 0 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 PROTECTED PREMISE Sari Diego County Credit Union #507 2530 El Camino Real Carlsbad, Ca 92008 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 ifi. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1 (800) 470-1000 Contractor License # 880138 fA~~Do 6 addressable fire system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC1XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XRI50FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on • Multiple on-board status LEDs XR550FC • Up to 100 output schedules to control relays and panel outputs Up to 142 two-wire smoke detector or fire initiating zones on • 32 individual reporting areas, with common areas • Output Groups: Maximum functionality—Minimum programming Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection XR1 5ODNFC/XR55ODNFC SYSTEM FEATURES Up to .7 Amps 12 VDC supervised bell output • All above listed System Features Up to 506 fully-programmable Form C relays • On-board Ethernet connection for Network MonitoringTM Serial 3 Digital Dialer or CID reporting to multiple receivers • Customizable check-in time and retry time Eight communication paths between the panel and Central Station • Suitable for multi-site applications where the Internet or Built-in remote or on-site feature upgrade capability LAN/WAN is available 1k!t1Y The XR1 5ODFC and XR5500FC provide basic fire monitoring for any single site application. The XR1 5ODNFC and XR55ODNFC panels provide all the same basic fire monitoring as the XR1500FC and XR550DFC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DAd. NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. 12 or 24 VDC NACI 12 or 24 VDC Sync Module Strobe lorn 12or24VDC Power Supply Sync Module Horn Strobe 505-12 or other 1 2/24VDC UL Motor Bell Commercial Fire Approved Digital Digital SLC Power Supplies Annunciator Bus I Loop I Digital SLC '., Additional 630F Any expansion device Loop 1 - Fire Command can operate on SLC Loop Centers 1 or2 630F Fire Command Center I FLEXIBLE COMMUNICATION The XR15ODNFC and XR55ODNFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path. the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. 1c:PEC SHEET --- --- ----------- -------- - EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignaL, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR1 50FC and XR550FC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LX_BusTM using Expansion Modules. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR550FC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary, panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX-Bus for Missing, Overlapping and/or Extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATEABLE The XR150FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR1 SOFC/XR55OFC feature updates release, perform the flash update remotely. OUTPUTS ------ The XR150FC and XR550FC allow the use of two SPOT relay outputs and four open collector outputs, that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 50FCand XR550FC panels can display keypad Status List and User Menu text using multiple Languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad locations. 12,000 EVENT MEMORY Allows the user to view the Last 10,000 door accesses or 2.000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindowsTM. The XR1 50FC and XR550FC include an interface connection for installers to use to connect a laptop computer. @1i F}( ) tLI3 11iki -- - KEYPADS 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS 263C COMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (At[ require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12/LX 5 Amps @ 12 VDC 505-12L 5 Amps @12VDC 505-12A 5 Amps @12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke, CleanMe 521 LXILXT Addressable Smoke/Heat. CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18 Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Corn patable with Central Station Receivers that accept Standard CID. DD, or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS TWO, / 1100X Receiver 1100XH High Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365, 366. 368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) ORDERING INFORMATION XR1 5ODFC-R XR1 50 Fire Control Panel LISTINGS AND APPROVALS Refer to the XR150FCIXR550FC Installation Guide (LT-1297). XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. XR1 5ODNFC-R XR55ODFC-R XR1 50 Fire Control Panel with Network XR550 Fire Control Panel XR550 Fire Control Panel with 0 4jx~ 250: North partnership Boulevard Designed. Engineered & Assembled Springfield, Missouri 65803-8877 in Springfield. Missouri I 6.8 Power Requirements During AC power failure, the XR1 50FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. All devices must be taken into consideration when calculating the battery standby capacity. The I following table lists the panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. Standby Battery Power Calculations Standby Current Alarm Current XR150FC/XR550FC Series Control Panel Qty 1 x 174mA 174 mA Qty 1 x 217mA 217 mA Relay Outputs 1-2 (ON) Qty _______ 30mA Qty _______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones 1-8 Qty ______ 1.6mA Qty ______ 2mA* Active Zones 9-10 Qty ______ 4mA Qty ______ 30mA 2-Wire Smoke Detectors Qty ______ 0.1mA Qty ______ 01mA Panel Bell Output 1 500mA mA 893A Dual Phone Line Module Qty x 12mA Qty _______ x 50mA 263C CDMA Cellular Communicator Qty x 13mA Qty ______ x 13mA 263H HSPA+ Cellular Communicator Qty x 24mA Qty _______ x 28mA 277 Buzzer Module Qty x 5mA Qty _______ x 5mA 1 100X Wireless Receiver Qty x 46mA Qty _______ x 46mA 1100XH Wireless High Power Receiver Qty x 160mA Qty _______ x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty x 34mA All four relays active 138mA I 38mA 865 Style V or Z Notification Module Qty x 26mA Qty _______ x 85mA 866 Style W Notification Module Qty _______ x 45mA Qty x 76mA 867 LX-Bus Style W Notification Module Qty x 30mA Qty _______ x 86mA 869 Dual Style D Initiating Module Qty x 25mA Qty _______ x 75mA 630F Remote Fire Command Center Qty _______ x 63mA Qty _______ x 92mA 7060/7160Thinline/7060AAquaLite Keypad Qty x 72mA Qty ______ x 80mA 7063/7163 Thinline/7063AAqualite Keypad Qty x 85mA Qty _______ x lOOmA 7070/7170 Thinline/7070AAqualite Keypad Qty x 72mA Qty x 87mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA 7073/7173 Thin line /7073AAqualite Keypad Qty x 85mA Qty _______ x lOOmA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7872 Graphic Touchscreen Keypad Qty x 145mA Qty ______ x 215mA Active Zones (EOL Installed) 1.6mA Qty x 2mA* 7873 Graphic Touchscreen Keypad Qty x 143mA Qty _______ x 243mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 734 Wiegand Interface Module Qty x 15mA Qty _______ x 15mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA 734N Wiegand Interface Module Qty x 146mA Qty x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA 734N-WiFi Wiegand Interface Module Qty x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA Copy Sub-Totals to next page Sub-Total Standby mA Sub-Total Alarm ______mA *Based on 10% of active zones in alarm. I Digital Monitoring Products XR150FC/XR550FC Series Installation Guide 10 6/5/14 DMP Commercial Fire UL listed control panels WILL NOT display a GROUND FAULT MESSAGE but rather a trouble condition on the LCD display. For DMP Commercial Fire UL listed control panels, Ground Faults are annunciated locally at the LCD display and transmitted to the Central Monitoring Station as a trouble condition as required. See the following. UL 864 Control Units and Accessories for Fire Alarm Systems 3.46 GROUND FAULT - A circuit impedance to ground sufficient to result in the annunciation of a trouble condition. NFPA 722010 23.5 Performance of Initiating Device Circuits (IDC) 23.5.2 An open or ground condition shall result in the annunciation of a trouble signal. 23.6 Performance of a Signaling Line Circuit (SLC) 23.6.2 An open, short circuit, or ground fault shall result in the annunciation of a trouble signal. 23.7 Performance of Notification Appliance Circuits (NAC) 23.7.2 An open or ground condition shall result in the annunciation of a trouble signal. Terry Shelton, MBA I Director of Technical Design Digital Monitoring Products I dmp.com 417.831.93621 Fax 417.447.9698 2500 N. PARTNERSHIP BLVD, SPRINGFIELD, MISSOURI 65803-8877 P-417,831.9362 800.641.4282 F-800,743.5724 www.dmp.com I SECURITY SIGNAUNS I LISTED I I I, i i ------------------ @L LISTED Your Source for Cellular Solutions —e XR550 and 263H HSPA+ Shown with XT30 and 263C CDMA Shown with 383 383 Rubberduck Antenna. Rubberduck Antenna. (Not to scale) The switch is on to cellular for many reasons. In isolated Locations, cellular may be the best primary communications path option. Where land lines could go down, cellular provides a reliable backup path. In critical installations Where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need. DMP has the technology to create reliable panel-to-central station digital cellular communications. Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station Uses digital cellular COMA or HSPA+ data networks in the US and Canada Transmits email and SMS status messages to multiple recipients I DIGITAL CELLULAR COMMUNICATORS CDMA&HSPA+ I SYSTEM FEATURES Modular add-on to XI or XR Series Panels • Check signal strength indication at the keypad Plug-and-play installation and activation of add-on • MyAccessTM Messaging features, including text message communication modules alerts from the panel, and ability to send commands to the U . Power from panel or separate power supply, with low panel via text messages current draw for long standby battery life • Supports the DMP App Fully supervised to ensure the health of communication • XR500EIXR550E provides privacy for your data with DMP I . DMP Adaptive TechnologyTM switches communication paths encryption technology white maintaining supervision if the current path becomes • XR1 00FCIXR500FC and 463C have FDNY approval for network unavailable on the XR SeriesTM panels or cell primary communication I . Direct reporting to any DMP Central Station receiver with no relaying or intermediary retransmission of alarm signals Can be equipped with local or remote antenna 75-2 . - - PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path. providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 263C/263H/463C can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or, use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones. Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable. Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available. communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the CDMA or HSPA+ wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Cellular Service from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, the unit is ready to use the SecureCom service. After installing the panel or card, activate the unit via Remote LinklM. After programming the panel. Remote Link recommends the optimum data plan based on the level of security, desired communication path configuration, and specific programming for the account. REMOTE CONTROL VIA MY ACCESSTM: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems, including the ability to arm /disarm, control outputs, retrieve system status, and perform automation functions. Each command received by the panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. REMOTE CONTROL VIA DMP APP The App provides Apple© iPhone and iPad owners, as well as Android users, with the ability to access a number of system functions remotely via cellular connection. As a dealer, the App provides the opportunity to load a company logo into the App. For both residential and commercial system owners, the attractive interface provides fast, easy access to the most commonly used system functions. APP CAPABILITIES At a glance, check system status including programmed areas. Arm or disarm the system in an instant Select from the Home/Sleep/Away arming options for home systems. Select from the All/Perimeter arming options for office systems Select from Area Arming Options Tap any programmed outputs to turn them on or off. Adjust lighting/thermostat/locks Video capability - up to six cameras, remote viewing. XTL SERIES The XTLC (CDMA) is available with on-board cellular which allows for MyAccessTM Messaging Email/SMS message commands to be sent directly to the panel. It is also available with on-board network or WiFi allowing for mobile App Control. This powerful burglary, residential fire, and door access panel provides cellular communication with built-in two-way wireless. Cr L CELLULAR (1L JNICATOR XR1 00/XR500 Series panel users can plug in the 463C expansion card to quickly and easily incorporate cellular communications. In the panel enclosure, it requires no additional enclosures, power supplies, batteries, cabling or conduit connections — simplicity available only from DMP. It can be equipped with local antenna that attaches to the panel, or where necessary for improved signal strength a remote SMA antenna can be used, offering more installation flexibility. The 463C draws half the current of other comparable units. With the long standby battery life of the system batteries, the 463C can continue to provide a communications link for up to 80 hours during a power failure with appropriate standby batteries. The 463C does not include a SIM card and is activated with the MElD number using SecureCom Wireless. -------------- DIGITAL L.LJ 1 7 NICATOR The 464-263H or462-263Ccel1ularmodules can be plugged onto the XR1 00/XR500 panel boards to add cellular communications inside the panel enclosure. It requires no additional enclosures, power supplies, batteries, cabling or conduit connections. They can be equipped with a Local or remote antenna. 263C/263H DIGITAL CELLULAR COMMUNICATOR For existing XT & XR150 1 XR350 I XR550 Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263C/263H allows alarm messages to be communicated to an SCS- I R or SCS-VR Receiver over their respective COMA orHSPA+ networks. It provides a fully supervised alarm communication path over the network. I The 263C/263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or I battery back-up is needed*. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263C does I not include a SIM card and is activated with the MElD number. All modules are ready for activation with SecureCom Wireless. I *4 381 cable is required for the XR1 501 XR350 I XR550 Series. ' The XR5001C Series Fire panels used with the 463C Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path. the 463C provides the security of a communication link that continues to function, even when land lines are cut or compromised. This interface works on the CDMA data networks over a variety of carriers in the USA. I TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in COMA 263C/263H 463C 464-263C/464-263H XT30IXT50 X XR100 Series X X XR500 Series X X XTL Series X XR15O I XR350 I XR550 Series X I ------- -------_--_ - -- L___ 263C/263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (263C) Standby 13mA Alarm 13mA Current Draw (263H) Standby 24mA Alarm 28mA 463C SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 22mA Alarm 22mA 464-263C/464-263H L, Primary Power 12 VDC from panel Current Draw Standby 15mA Alarm (Nominal) 48mA Peak (-150mS) 85mA 2630/263H COMPATIBILITY )Cr Version 112 or higher & XR1 50 I XR350 I XR550 Series Panels (A 381 cable is required for the XR1 50 I XR350 XR550 Series) 463C COMPATIBILITY DMP XR1 OOIXR500 Series panels using Software Version 202 or higher 464-263C/464-263H COMPATIBILITY DMP XR1 00IXR500 Series panels using Software Version 212 or higher ACCESSORIES 381-2 18' Coax Extension 381-12 12 Coax Extension 381-25 25 Coax Extension 383 Rubber Duck Antenna 386 Wall Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna 387-4 4' SMA to N Extension Cable 387-8 8' SMA to N Extension Cable 387-25 SMA TO N CABLE, 25FT, LM R1 95 387-50 SMA TO N CABLE, SOFT. LM R1 95 C 263C CDMA Cellular Communicator (Verizon) 263C/381-2 CDMA Cellular Communicator w/ 381-2 Cable (Verizon 463C CDMA Cellular Communicator (Verizon) 263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (263HCAN - Rogers)) 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T. T-Mobile. (263HCAN - Rogers)) 464-263C CDMA Cellular Communicator (Verizon) 464-263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (464-263HCAN - Rogers)) L .' 263C/263H/463C California State Fire Marshal (CSFM) 263C/463C/464-263C FCC ID: MIVCNNO301 Industry Canada: 6160ACNN0301 263C/463C/464-263C Verizon Certified 263H PTCRB Certified (AT&T) 263H/464-263H FCC ID: RI7HE91ONA Industry Canada: 5131 A-HE91 ONA 463C New York City (FDNY COA #6123 & #6145) Underwriters Laboratories (UL) Listed 263C/263H ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarms Units and Systems Accessory ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglary ANSI/UL 1635 Digital Burglar ANSI/UL 864 Fire-Protective Signaling 9th Edition (XR1 50 p XR350 I XR550 Series Panels only) 463C ANSI/UL 365 Police Station Connect Burglar Alarm Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 864 Control Units for Fire-Protective Signaling Systems 464-263C/464-263H ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units Underwriters Laboratories Canada (ULC) Listed 263H (XR150 I XR350 I XR550 Series Panels only) ULC S304-06 Central Station Burglar ULC Subject-C1023 Household Burglar ULC/ORD-C1076 Proprietary Burglar ULC 5545 Household Fire ULC S559-04 Equipment for Fire Receiving Centers and Systems 464-263H ULC/ORD-C1 076 Proprietary Burglar ULC S304-06 Central Station Burglar For additional information, access www.dmp.com and select Compliance. I 4282 dm 641. p.com 2500 North Partnership Boulevard 800. I Springfield, Missouri 65803-8877 Designed. Engineered & Assembled in Springfield. Missouri -- - -r -I Effective, cost-efficient DC power supplies Suitable for fire, access control, and burglary system applications Perfect for any 12 VDC application Primary applications include notification appliance circuit (NAC) expansion and auxiliary power to support burglary and access control accessories. Search drripalarms SECUR - SIGPJAUNG You I LISTED 12 Volt Power SuppHes ReliablerL;IE; any Application DMP power supplies are a reliable and versatile choice. 505 SERIES POWER SUPPLIES FEATURES Regulated and filtered power system Power-indicating LEDs Built-in overload protection Battery backup/charging circuit 5 Amp output 12 VDC power supplies Battery cutoff to prevent deep discharge of batteries Rugged cold-rolled steel enclosure Lock-and-key mechanism for security Optional tamper switch 505-I2LX ADDITIONAL FEATURES Connects to the LX-Bus of the XR1 00 and XR500 Series Provides 2 independent Class B NAC outputs L1r- 1P 0o T 6 U, P0 !7777VISUAL INDICATORS Each power supply provides a green AC power LED and a red DC LED for a visual indication of the power supply input and output voltage status. Charging circuit for a battery backup included with each power supply. TRANSIENT PROTECTION AC input and DC output circuits include metal oxide varistors (MOVs) for transient protection. MONITOR AC INPUT The power supplies monitor the AC input voltage for power failure or brownout conditions. During AC power failure, current is supplied by the backup battery until AC power is restored. BATTERY CUTOFF RELAY The battery cutoff relay is included to prevent deep-discharge of the battery which helps reduce the risk of damage to the battery or to the power supply itself. ENCLOSURE FEATURES The power supplies are mounted and stabilized in rugged enclosures for protection from the elements. Each enclosure includes a lock and key and provides space to include a backup battery. Optional tamper switches may be mounted in the enclosures to monitor door tampering. 505 SERIES The 501 Series power supplies are power limited, switching power supplies that meet UL. CSFM. NFPA. and FCC standards. The 505-12 provides 5 Amps of continuous power. 505-12A AND 505-12L The 505-12A is mounted in a gray 350A Grade A, attack-resistant enclosure with lock and key and a tamper switch. The 505-12L is mounted in a red or gray 350 enclosure with lock and key. 505-12LX The 505-12LX power supplies include all of the features of the 505-12. The LX version includes two independent Class B NAC outputs. Using an 867 Notification Module provides an on-board Power Supply Monitor LED to indicate any loss of power from the auxiliary power supply. All trouble indications are communicated to the FACP via the 4-wire LXBusTM digital loop. DIGITAL LX-BUSTM FEATURES The 505-12LX power supplies connect to the FACP via a 4-wire LX_BusTM (SLC) loop. This connection supervises communication between the panel and the NAC modules. Trouble conditions on the NAC circuit (Ground Fault. Open. Short, power supply AC or Battery trouble) or loss of communication between the NAC module and the FACP. cause the specific trouble condition to be indicated at the system keypads and reported to the Central Station. NAG MODULE FEATURES Provides steady, pulsed. Temporal Code 3, and California Schools Code bell outputs. Supervised silence switch disables the bell output during service or maintenance. On-board status LED indicates good communication with the control panel. Rotaryswitches provide easy addressing. ACCESSORIES 867 Notification Module 307 Clip-on Tamper Switch 307-S Screw-on Tamper Switch 3012 Clip-on Tamper Switch Sealed lead-acid rechargeable batteries PANEL COMPATIBILITY DMP Power Supplies are compatible with all DMP panels. LISTINGS AND APPROVALS California State Fire Marshal (CSFM) FCC Part 15 Underwriters Laboratories (UL) Listed UL 294 Access Control System Units UL 603 Power Supplies for Use with Burglar Alarm Systems UL 1481 Power Supplies for Fire Protective Signaling Systems SPECIFICATIONS Voltage/Current Input 120 VAC @ 1.5 Amps Voltage/Current Output 12 VDC © 5 Amps max. Secondary (Battery) Power Charge Current 1.5 Amps max. Current Draw 200mA Only use sealed lead-acid rechargeable batteries. For additional information, access www.dmp.com and select Compliance. WMV DlØt.1 M..iti..9 P&&t j 2500 North Partnership BouLevard 8006414282 dmp.com Springfield, Missouri 65803-8877 Made in the USA Superior Notification Options DMP Notification Modules provide quality supervision for faults, such as grounds, shorts, and opens. 12 or 24 VDC, UL Listed devices Devices alert on-site personnel of fire and burglary alarms Silence switch can disable module bell output during service and maintenance Select the module that is best for your application. I 8659 8669 8677 U - NOTIFICATION MODULE FEATURES 867 FEATURES Powered from panel. or auxiliary power supply I Provides Steady, Pulse, Temporal Code 3, and California Suitable for use wth 2 VDC or 24 VDC devices Schools Code bell outputs Supervised Silence Switch disables the bell output Provides supervision for opens, shorts, and ground fault I . during service or maintenance conditions on the belt circuit Provide supervised Style W 2-wire circuit for notification On-board status LED indicates panel communication is appliances good I 86S LEATURES On-board Power Supply Monitor LED indicates loss of Provides one 4-wire circuit or two 2-wire circuits power from an auxiliary power supply Provides Style Y, L W, or X notification circuit for the . Easy rotary addressing; no difficult binary switches connection of appliances Ideal for mounting near notification devices Provides one Trouble a nd one Ground Fault LED Connects to the 4-wire LX-Bus on XR500 Series, XRZOO, or XR200 485 panels Supervises UL listed, 3olarized notification devices Allows installation of multiple Style W notification devices 'Supervises auxthar 2pEy I - --- C INSTALLING THE NOTIFICATION MODULES You can install the Notification Modules in any of the panel enclosure three-hole mounting locations using the plastic standoffs provided. NOTIFICATION APPLIANCES The 865, 866, and 867 Modules easily connect notification appliances, such as horns and strobes. By connecting the appliances in parallel, it is possible to connect several appliances to one module. Referto the module installation sheet for more information. AUXILIARY POWER SUPPLY You can connect a maximum 5 Amp, 12 or 24 VDC UL listed auxiliary power supply to the Notification Modules to support alarm power requirements beyond the panel alarm output capacity. SILENCE SWITCH OPERATION The Silence switch on the Notification Modules allows technicians to test or perform maintenance on the DMP fire system without sounding the building's fire alarm notification devices. POWER SUPPLY SUPERVISION The panel can supervise the auxiliary power supply through the normally closed trouble contacts on the power supply that also connect to terminals 7 and 8 on the 866 and 867 Modules. When the bell circuit is in a bad condition, the modules indicate the bad condition to the panel. 865 DESCRIPTION The 865 is suitable for use with 2- or 4-wire Style Y, Z, W, or X circuits. It provides one Trouble and one Ground Fault LED and a set of trouble contacts to indicate off normal conditions. 865 SELECTABLE CIRCUIT STYLES By setting a jumper on the 865 Module, you may use Style W (2-wire) or Style X (4-wire) notification circuits to connect appliances. You may also use Style Y (2-wire) or Style Z (4-wire) circuits. This flexibility allows the use of one module in a variety of applications. 866 DESCRIPTION The 866 Notification Module provides one 5 Amp Style W notification circuit for supervising UL Listed, polarized notification devices such as bells, strobes, and horns. The 866 is compatible with DMP Command Processor panels. MULTIPLE 866 MODULES You may install up to 25 Model 866 Style W Notification Modules on each XR500 Series XR200, XR200-485 panel by using the relay outputs available on the panel. 867 DESCRIPTION The 867 connects to the panel LX-Bus and provides one supervised Style W circuit, and four LEDs to indicate circuit Trouble and Ground Fault conditions. 867 ADDRESSING The 867 has two pairs of rotary switches. One pair sets the module Bell Relay Address. The second pair sets the Supervisory zone address. Having a separate Bell Relay Address allows multiple modules to be activated in groups and yet monitored by individual Supervisory zones. 867 BELL RING STYLE You can specify the bell output cadence on the 867 module by setting the Bell Ring Style jumper for Steady, Pulsed, Temporal Code 3, or California Schools. The 867 can then be activated by the Fire Bell output or by a panel Zone Alarm Output. POWER SUPPLIES 502-12 Provides 2 Amps @ 12 VDC 505-12/LX Provides 5 Amps @ 12 VDC 508 8 Amps @ 12 or 24 VDC PANEL COMPATIBILITY 866 and 865 Modules - all DMP Command Processor panels. 867 Module - XR500 Series, XR200, and XR200-485, Command Processor Panels. 865 MODULE SPECIFICATIONS 867 MODULE SPECIFICATIONS Operating Voltage 9.6 to 14.2 VDC from panel Operating Voltage Current Draw LX-Bus: 8.0 to 15.0 VDC Standby: 26mA, Bell Power: 10.2 to 28 VDC Maximum: 85mA Operating Current Maximum Alarm 5 Amps ® up to 30 VDC LX-Bus: 30mA maximum Circuit Styles One 2-wire Style W or Y Bell Power: 30mA standby, 80mA maximum or One 4-wire Style X or Z Alarm-Switching Current 5 Amps at 12 or 24 VDC 866 MODULE SPECIFICATIONS Module Dimensions 3" x 5" Operating Voltage 12 VDC LISTINGS AND APPROVALS Current Draw (from panel) Underwriters Laboratories (UL) Listed Standby: 45mA, UL 864 Fire Protective Signaling Maximum: 75mA UL 985 Household Fire Warning Contact Ratings UL 1023 Household Burglary Alarm 5 Amps at 24 VDC resistive FCC Part 15 Trouble 2 Amps at 30 VDC resistive I 2500 North Partnership Boulevard Digital Monitoring Products Springfield, Missouri 65803-8877 .9 Or@ U SECURTTY SIGNAUNG NYC MEA LISTED The most affordable I codeless arming and disarming available - I with a slim new look! I I __— i I I iT 3 4 7000 Series Thinline LCD Keypads offer f high quality, cost-effective security control in a CHIM I stylish, sleek new design. I Visual and audible alarm notification Silence alarm while system remains armed II Optional integrated proximity reader I Four optional on-board fully programmable zones I . Retrofit to any DMP panel Enhanced Options 7063 and 7073 keypad proximity readers accept DMP 1 1300 Series proximity credentials. THUMLIME Tm LCD KEYPADS 7060170631707017073 FEATURES Attractive Thinline keypad housing available in several colors Large, 32-character, Liquid Crystal Display (LCD) Custom 16-character home or business name Keypad and logo backlighting turns Red in alarm conditions User-adjustable brightness, tone, and volume controls Supports Cancel/Verify feature Built-in diagnostics for ease of service Simple harness connection to 4-wire keypad bus Connect devices directly to keypad zones View system events/user activity through keypad display AC power and Armed LED Suitable for access, burglary, and fire applications Distinct fire, burglary, zone monitor, and prewarn tones Displays time of day, armed zones, and armed areas Optional backboxes for conduit or wall-mount applications Unique silence feature allows the user to silence alarm bells and still keep the system armed Compatible with all DMP panels VERSATILE SUPERVISED AND UNSUPERVISED OPERATION When programmed for supervised operation, the keypad occupies its own unique device address on the keypad data bus. Unsupervised operation allows you to install an unlimited number of keypads set to the same device address. Increasing the number of keypads allows maximum system operating flexibility. USER-FRIENDLY MENU FUNCTIONS The User Menu allows you to quickly browse through menu options. Disarming and Arming functions are fast and easy. Any function allowed by the user authority level is simply accessed through the keypad, such as silencing alarms, resetting sensors, or displaying events. 2-BUTTON PANIC KEYS The top row of keys can be used as 2-button panic keys. The user simply presses and holds two of the keys simultaneously to send either a panic, non-medical emergency, or fire report to the Central Station. Top Row Select Keys f Police Emergency ire Label shows Icons only Panic Key Labels CANCEL/VERIFYTM In a Home/Sleep/Away or All/Perimeter system, you can CANCEL a burglary alarm or VERIFY that a valid burglar alarm has occurred. Selecting VERIFY manually verifies the alarm and sends an alarm verification message to the central station. KEYPAD SHORTCUT KEYS Keypad shortcut keys are provided to simplify operation and allow the user to more quickly arm, check in, monitor, exit, or reset the system. One-button arming creates the simplest keypad available. Use the one-button shortcut keys for common functions, or use the ATM style menu for advanced functions, whichever method meets the user's needs or level of expertise with the system. END-USER CONTROL Each of the Thinline Series keypads provides a simple User Options menu for adjusting brightness, speaker tone, and volume. VALUABLE VISUAL ALARM INDICATOR In a normal state, both the keypad and logo backlighting remain Green. However, during an alarm state, the keypad and logo turn Red. The change in color allows persons on-site to instantly recognize an alarm condition. Red Backlighting JdL. --, -. - 8 - -# DISTINCT SOUND PATTERNS The keypads also provide distinct sound patterns for fire, burglary, zone monitor, and prewarn that can help users identify the event occurring on their system. RETROFIT ANY EXISTING DMP SYSTEM Retrofitting is quick and easy. Thinline keypads have the same footprint as existing DMP keypads and mount in currently installed backboxes. Thinline Series keypads require no special modules or panel upgrades. You can provide a new look and greater functionality to an existing system at just a fraction of the cost of all new equipment. MULTIPLE-KEYPAD SAVINGS Install multiple keypads on the same wire run. Compatibility and cost savings make the Thinline Series an asset in every installation. OPTIONS The Thinline Series keypads also provide Keypad Options and Keypad Diagnostics menus available only to system installers and service technicians. Enter Keypad Options to set the keypad address and change the default keypad message. Test the keypad operation at any time without disabling the system. The diagnostics program tests the LCD segments and backlighting, each of the 16 keyboard keys, and the four zones on the 7070 and 7073 keypads. I I Green Backlighting nrrr 1 UNIVERSAL PROGRAMMING TOOL System installation and programming can be achieved without carrying around or purchasing expensive external programmers since panel and add-on module programming is integrated into DMP Keypads. Individually program panels, an iCOM Network Alarm Router, iCOMSL Network Alarm Communicator, and other programmable add-on modules directly from the keypad. 707017073 FOUR EXPANSION ZONES Zone expansion is available right on the keypad where you need it the most. The four expansion zones on the 7070 and 7073 models are fully programmable Class B protection zones that can be used for a variety of fire, burglary, and access control applications. ZONE TYPE SELECTION Keypad zones can be programmed using the same zone types available on the panel. Select supervised, unsupervised, night, fire, panic, exit, and emergency operation depending on the user requirements. ZONE DEVICE CHOICES Connect PIRs, door and window contacts, pull stations, sprinkler tamper switches, and silent panic buttons. Plan the installation to afford the best coverage while eliminating potential problems associated with multiple wire runs. 7063/7073 CODELESS ARMING AND DISARMING The innovative 7063 and 7073 Thinline keypads contain an on-board DMP proximity reader that allows users to simply present their proximity credentials to the keypad to gain access to a protected area. 7073 SOFT-SHUNT® MOMENTARY BYPASS To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the Soft-Shunt® feature. Soft-Shunt allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open /short is sent to the panel for the keypad Zone 2. REQUEST-TO-EXIT (REX) To enable easy user exit from an area, connect a motion sensing or mechanical device to Zone 3 on the keypad. As the user trips the zone, the keypad activates the door strike allowing the user to exit the area without presenting a card or entering a user code. PRIVATE LABELING DMP offers dealers the option to present their company Logo on the 7000 Series keypads. The logo displays on the rubber logo insert and replaces the DMP logo. The backlighted logo glows Green during normal operation and turns Red in an alarm state. Logo Location - Place Your - - , Logo Here U I KEYPAD MODEL FEATURES Model 2-Button Panic Red in Alarm 4-Zones Internal Prox Reader Wiegand Input Internal Form C Door Strike Relay 7060 X X 7063 X X X 7070 X X X 7073 X X X X X I I I _ Digital Monitoring Products KEYPAD ORDERING INFORMATION The Thinline Series keypads are available in White, Ivory or Black to complement any decor. Select from the following options: KEYPAD ACCESSORIES Backboxes 695 Keypad Conduit Backbox 696 Keypad Backbox Keypad Wiring Harness 300 4-wire harness 300-5 5-wire harness 300-12 12-wire harness 300-512 12-wire harness, 5 ft. tong Proximity Credentials 1306 Prox Patch' 1306PW Prox Patch 1326 ProxCard H® Card 1346 ProxKey Il® Access Device 1351 ProxPass® 1386 ISOProx Il® Card External Proximity Readers PP-6005B ProxPointo Plus Proximity Reader MP-5365 MiniProx1 Proximity Reader PR-5455 ProxProo II Proximity Reader MX-5375 MaxiProx Proximity Reader TL-5395 ThinLine 111, Proximity Reader 7060-W 7063-W 7070-W 7073-W 7060-I 7063-I 7070-1 7073-1 I 7060-B 7063-B 7070-B 7073-B SPECIFICATIONS Operating Voltage 12 VDC Dimensions 7" W x 5.25" H x 0.5" D Display Type LCD Colors White, Ivory, Black COMPATIBILITY 7000 Thinline Series keypads are compatible with all DMP panels. Thinline keypads are not available in a Fire Keypad Variation. CURRENT DRAW 7060 Standby 72mA Alarm 87mA 7063 Standby 85mA Alarm lOOmA 7070 Standby 72mA + 1 .6mA per active zone Alarm 87mA + 2mA per active zone 7073 Standby 85mA + 1 .6mA per active zone Alarm lOOmA + 2mA per active zone I Digital Monitoring Proth,cts LISTINGS AND APPROVALS California State Fire Marshall (CSFM) FCC Part 15 ID: CCKPCO086 Industry Canada ID: 5251A-PC0086 New York City (MEA) Underwriters Laboratory (UL) Listed ANSI/UL 294 Access Control System Units ANSI/UL 365 Police Connected Burglar ANSI/UL 609 Local Burglar ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 864 Fire Protective Signaling 9th Edition (7070,7073) For additional information, access www.dmp.com and select Compliance. a o 89@999 a GA 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 SECURITY SIGNALING LISTED Simple Expansion Solutions 1 71/1O • I Expand your DMP Command Processor' panel options I with a wide array of expansion modules. 1 Loll • Add supervised Class B burglary zones. I - . • Connect non-powered burglary or fire type - devices for intrusion, glassbreak, and motion detection. I / • Add 12 VDC zones for addressable 2-wire smoke - detectors with 715 moduels. I I ZONE[EXPAMSCO N MODULES: SUG1GflE AND MUMPILE P©flET ZONE EXPANSION MODULE FEATURES Provides Class B zones for burglary and fire • Easy connection to 4-wire keypad or LX-Bus I . Compatible with DMP Command Processor Panels that allow • Proven design ensures stability and performance zone expansion • Data LED on zone expander indicates good panel Suitable for mounting near protection devices communication Connect devices using 4-wire bus • Durable and attractive plastic or metal housing Easily mount attractive cases on wall or 3-gang box • Low current draw Compatible with all panel zone types • Can be powered from panel or auxiliary power supply Ii 7Z ) INi rE IE rP' IN1 S fl ) rn [?"fl c rt tLJ rL rE S________ USE ON THE DMPLXBUSTM 708 BUS EXTENDER MODULES 710 CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, 715-16, and 725 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the cover snaps on to form tight-fitting protection against incidental contact or tampering. 714-8, 714.16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708, 710, 710F, and 725 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorats to remote DMP SCS-1 R Receivers. noise on the wires. The 708 Bus Extenders are received from the factory as a pair of modules that connect between the panel and LX-Bus or keypad bus devices. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710171 OF BUS SPLITTER! REPEATER MODULES The 710 and 710F Bus Splitter/Repeater Modules allow you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710/710F Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional 12 VDC LX-Bus or keypad bus circuits. This makes the 710 module an excellent junction box when terminating multiple LX-Bus/keypad bus runs at one Location. As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 710F As well as providing all of the functions of the 710 listed above, the 710F also allows you to use the 725 Zone Expander to expand the number of 24 VDC zones. The 710F Bus Splitter/Repeater allows the connection of a 24 VDC power supply to the 725 to power smoke detectors and isolate the 24 Volt source from the panel. Therefore, the 710F must be used when using the 725 Zone Expander. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP Command Processor panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included The modules can be used on the LX-Bus The 708 Bus Extender Modules allow you of DMP Command Processor Panels. The to increase the length of wire used to run modules connect to the 4-wire bus and an LX-Bus or keypad bus by a maximum of use only one zone address. To assign an 4,000 feet, while providing immunity to additional zone expander use the next available zone address. 7141715 FEATURES I Four protection zones on each module I . Comes with 12-conductor wire harness Optional 12-position screw terminal I I 1 I s G=> Is rxj 714-8,714-16,71 5-8, AND 725 24 VDC EXPANSION 714/715 ZONE EXPANDERS The 714 contains four Class B burglary 715-16 DESCRIPTION MODULE zones and is suitable for use with burglary The expanders are housed in a Model The 725 provides four 24 VDC powered and fire devices that are normally opened 340 locking metal enclosure suitable zones that enable you to connect or normally closedjndividual zones are for mounting in a remote location. 2-wire smoke detectors to the XR500 - supervised with 1k Ohm EOL resistors and Each expander provides screw terminal can be programmed with any burglary or strips for zone inputs and data bus I I I I I fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 7181 Plug-in Screw Terminal. The enclosure can also accommodate the 7191 Terminal Boards for the 714 or the 7201 Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 7201. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. 714-8/714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8171 S- 1 6 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. 714-8,714-16,715-8, AND 715-16 FEATURES -8 or 16 protection zones per expander Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14 to 22 gauge wire for easy connection Suitable for mounting in a remote location Series, XR2500F, XR200, and XR200-485 Command Processor Panels. As a result, the 725 provides you the flexibility to retrofit a 24 Volt system without the need to run more wire or change to 12 Volt smoke detectors. 725 FEATURES Provides four 24 VDC zones Sensor reset performed through panel relay or 716 Output Expander Powered from 24 VDC power supply Supervised operation 24 Volt surge protection from 710F Provides ability to use 24 VDC 2-wire smoke detectors Easily mounted in 3-hole pattern 711 DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. ill FEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing connections, a two position jumper to designate connection to the keypad bus or the LX-Bus, and an LED to indicate communication with the panel. Separate zone End-of-Line resistors are included with each expander. • __ I Digital Monitoring Products ci 0 — = o — _ ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-Hole Plastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC AILDMP 12 VDC 710 N/A N/A Yes Yes 12 VDC 710F N/A N/A Yes Yes 712-8 Dip Switch 8 Yes No 12 VDC XT Series, XRI00/XR500 Series, XR2500F 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure 725 Rotary 4 24 VDC Class B I No Yes 24 VDC XR500 Series, XR2500F P1 L MODULE SPECIFICATIONS 708 SPECIFICATIONS (NONE UL) Operating Voltage 8.8 to 15.0 VDC Operating Current 20mA Per Pair Dimensions 4.5" X 2.75" X 1.75" Maximum Distance 4,000 feet between the two 708 Modules 710171 OF SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 710 30mA 710F 40mA Dimensions 4.5" X 2.75" X 1.75" Distance 2,500 feet (one module), 15,000 feet maximum III SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current Average 11 m + 1.6mA per active zone Alarm 11 mA + 2mA per zone in alarm Zone Voltage 5 VDC (1.6mA across EOL) Dimensions 4.5" X 2.75" X 1.75" 712-8 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Current Draw 17mA + 1.6mA per active zone 17mA + 2mA per zone in alarm Dimensions 4.5" H x 2.5" W 725 SPECIFICATIONS Operating Voltage 24 VDC Nominal Average Current 8mA + 4mA per active zone Alarm Current 8mA + 4mA per active zone + 30mA per smoke in alarm + 47mA per shorted device EOL Resistor Model 316 6.8k EOL 7141715 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714 Average 7mA + 1.6mA per zone Alarm 7mA + 2mA per zone 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 7mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Dimensions 4.5" X 2.75" X 1.75" 714-8,714-16,715-8, AND 715-16 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714-8/16 Average 20mA+ 1.6mA per zone Alarm 20mA + 2mA per zone 715-8/16 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 20mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Enclosure 20-Gauge cold-rolled steel Dimensions 12.5" W 11.5" H x 3.5" D 714-8/-16 Color Gray 715-8/-16 Color Red LISTINGS AND APPROVALS Refer to the appropriate panel programming and installation guide for specific compliance listings for installation and programming requirements necessary to meet a particular approval. Underwriters Laboratories (UL) Listed California State Fire Marshall (CSFM) New York City MEA accepted (711, 714, 715 only) For additional information, access www.dmp.com and select Compliance. _M;1 I 000-WA19 0 IO u 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 I Email: tshelton@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, I remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: I XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures I 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads I 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders I 716: Output Expander 717: Annunciator Module 860 Relay Module 893A: Dual Phone Line Module I 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module I 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 263H: Cellular Communicator *(May be used as the standalone primary communicator) I 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch I 1100X, 1100XH: RF Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren I *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator I Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. Rev 04-08-15 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1157:0114 Page 1 of I ' CATEGORY: 7315 -- POWER UNITS LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models 505-12, *50512A *50512L 505-I2LX, *505..12u(L *50512u(A 504-24, 504-24LX power supplies/battery chargers. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12or24VDC In accordance with listee's printed installation, applicable codes & ordinances and in a INSTALLATION: manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as power supplies/battery chargers to provide auxiliary power for fire alarm and access control systems. Refer to listee's Installation Instruction Manual for details. NOTE: [1 I I I I H H Rev. 06-24-2005 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division