Loading...
HomeMy WebLinkAbout7750 EL CAMINO REAL; ; FPC2021-0059; PermitPERMIT REPORT (r,city of Carlsbad Print Date: 11/03/2021 Job Address: 7750 EL CAMINO REAL, CARLSBAD, CA 92009-8517 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2161241600 Track U: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms Orig. Plan Check U: Plan Check U: Permit No: FPC2021-0059 Status: Closed - Finaled Applied: 04/22/2021 Issued: 09/21/2021 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: Project Title: Description: BEACON PHASE II - REVISED PLANS FOR WET PIPE AUTOMATIC SPRINKLER SYSTEM FOR EXISTING BLDG C (327 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, U STE 14 1341 DISTRIBUTION WAY, U STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 FIRE NFPA 13 System > 100 heads Add'l Inspection $112.00 FIRE Plan Review (per hr - Regular Office Hours) $223.50 FIRE Reinspection (per Inspection) $212.00 FIRE Reinspection (per Inspection) $212.00 Total Fees: $1,617.50 Total Payments To Date: $1,617.50 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov (ITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS BEACON BLDG. C 7750 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Dlstñbution Way, Su& 14- Vita, CA 9201 760-295-3$81 —phona - 760.295-3437— fax www.titanfpinc.com Page "L ENMN Municipal Water District Fire Flow Test Results Asset ID # WFHD3117 I I EAM# 340713 Flow Test Requested By:: Mayra Marron Telephone: 951-302-2163 Email: mmarron@titanfpinc.com Project Name:7720 El Camino Real )MWD Personnel Conducting: Mike Salazar, Bryan Rickards Date: 3/8/2021 1~:rn11:20a ddress:7720 El Camino Real k ounty: San Diego Pressure Zone: Hydrant (flow) Elevation: 58feet Pipe Diameter: 8 inches Hydrant (gauge) Elevation: 63feet Pipe Diameter: 8 inches Reservoirs Involved: P.R. Stations Involved:: rsf north & south, village park, la costa, vales 1, gardendale, southeast 2, wanket, quails Distribution System: Dead End Looped Static Pressure (prior to flow test): 167 P.S.I. Residual Pressure (during flow test): 145 P.S.I. PlTOT Residual Pressure, 2 1/2 inch port: 110 P.S.I. Calculated Flow: 1 696 G.P.M. Comments: lest Results Reviewed By: MS Job Name FOR HYDRAULIC CALCULATIONS Job Location - REFERENCE ONLY. INSTALLATION BY Engineer _____ OTHERS. 110. No Approval Representative 'A fj i I IL.T14 Detector Backflow Prevention Assemblies The FEB00 MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-.health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. The coating on this backflow assembly uses ArmorleklM technol- ogy to resist corrosion duo to microbial induced corrosion (MIC) or exposed metal substrate. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler sys- tems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal"N-Pattern" Installations Vertical-Up 2-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Utilizes advanced Arn1orTekM coating technology to resist cor- rosion of internals Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between tst & 2nd Check Components Captured 0-ring Design Auxiliary Bypass Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4 Check Assembly No Special Tools Required for Servicing Field Replaceable Seat & Disc Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF876V Double Check Detector Assembly Specifications The FEB00 MasterSerios LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL' FM inlet/outlet resilient seated shutoff valves and contain four (4) properiy located resilient seated test cocks as specified by AW/VA Standard C510. The auxiliary bypass line contains a %'x%" Water Meter that complies with ANSI/AWWA Standard C700 coupled with an approved check assembly, The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The valve body shall utilize a coating system with built-in electrocheml- cali corrosion inhibitor and microbial inhibitor. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of A\MNA Standard C510 flow and pressure loss performance parameters, The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety Information before beginning the installation of this product. Inquire with governing authorities for local installation requirements *The wetted surface of this product contacted by consumable water contains less than 0.25!/o of lead by weight. FERCO product specifications In U.S. customary unto and metric are apprordrnato and are provided for reference onl For precise measurements, please contact FERCO Technical Service. PERCO reserves the right to change or modify, product design, construction, specifications, or materials with- out prior notice and without Incurring any obligation to make such changes and rrrodiflcallonson FERCO products previously or oubsequenttrsold A WATTS Brand Shutoff Valves: OSY resilient wedge gate valve ,A (uL'Frvr) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: AWWA C606 Options - Suffix OSY: UL/FM Approved OS&Y Gate Valves [ANSI/AWWA C515 Compliant] DNRS: Domestic Non-Rising Stem Gate Valves [ANSI/AWWA C509 Compliant] CFM: Totalizing Cubic feet/min Wx 1/4 Water Meter [ANSI! AWWA C700 Compliant] GPM: Totalizing Gallons/mm %x 3/4"Water Meter[ANSI/ AWWA C700 Compliant LO: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4 LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4 LF876V-OSYCFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer; FDA Approved (ASME 616,11 Class 125 & AWWA Class D Flange] Series 611 Valve Setter MJ x MJ Mechanical Joint x Mechanical Joint [AWWA C111/A21.11] MJ x FL - Mechanical Joint x Range [AMA C111/A21.11; ASME B1 61 Class 125/AWWA Class D Flange] FL x FL - Flange x Flange [ASME B16.1 Class 126 & AWWA Class D Flange] Materials Below is a general materials list of the Model LF876V All assemblies size 21/2" through 10" is similar in materials and construction. Please contact your local FEBCO Representative if you require further information, Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA C550-90 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard C510 Compliant End Connections: Compliant to ASME 516.1 Class 125 & AWWA Class D Flange "Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations, Assembly Flow Orientation: Horizontal (N-Pattern 21/2 - 10) - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Lip (Z-Pattern 21h - 10) - Approved by FCCCHR-USC, ASE, cULus, FM, IAPMO/cUPC C C e Approved C®US 1048 864.5 Pressure - Temperature Max. Working Pressure: 175psi (12,1 bar) Mm. Working Pressure: lOpsi (0,7 bar) Hydrostatic Test Pressure: 350psi (24,1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F (0.5°C- 60°C] Continuous Dimensions - Weights Size: 21/21' - 10" Below are the nominal dimensions and physical weights for the Model LF876V size 2½' through 10". Allowances must be made for normal manufacturing tolerances. Please visit our websfte to download a copy of this product's installation instructions, or contact your local FEBCO Representative for more information, Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) 'I Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE DIMENSIONS h A In, mm B in. mm C in mm 0 In, ,nm 6 In, mm F in, mm S in, mm fri in, mm in mm J il mm l(" in mm L in, fl1'p OSY Ibs, kg, 2½ 291A 740 121h 318 61/4 159 251/4 642 171/2 445 13% 346 271/4 692 51/2 140 111/8 283 31h 69 16/, 416 11½ 292 216 98 3 291/h 740 121h 316 61/4 159 251/4 654 173/4 451 141/, 359 281/4 718 51/2 140 111/, 283 3Y4 95 1W/s 479 111/2 292 242 110 4 31½ 791 14 356 7 176 27% 705 181/4 476 151h $94 31 187 6 152 111/8 283 41h 114 22% 578 13 330 347 157 6 351/4 908 16 406 8 203 32/4 831 221A 562 18'/ 473 37'/a 946 r/4 184 121h 316 51h 140 301A 765 13 330 529 240 8 401/4 1035 18½ 470 81/4 36~ 933 25¼ 638 20~ 527 41½ 1054 8½ 216 14 356 6~ 172 37~ 959 14½ 368 827 375 10 46% 1175 21 533 10'/is f26":4 4Wis 10471281/a 714 23'/ts 601 473/8 120219 5/8 244 15h1/1 396 8 203 453/4 11621131A 333 1335 606 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) ** Indicates weight of complete Bacictiow Assemblies with specified Gate Valves 60 LF87SV PSI 18 16 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 l600gpm 757 2271 3785 5300 1pm 7.5 11.4 17.0 fps Service Flow Rated Flow *j9. Rated Flow - - -/---- _L —r pal 8" LFS76V Service Flow Rated Flow *IJL Rated Flow 18 18 14 'I 12 0 400 800 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 Ips 0 500 1000 1500 2000 2500 3000 35009pm 1812 3785 5678 7570 9463 11356 13248/pm 75 9.4 14.l fps 10" LFS7BV pal 10 a 8 7 oil 6 5 4 i: 3 0 Service Flow Rated Flow UL Rated Flow Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.51ps. AWWA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps, UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern te,rr1 2W' LF876V Service Flow Rated Flow *111. Rated Flow 22 20 I 18 I 10 0 25 50 75 too 125150175200225250275300325350gpm 284 568 852 11$6 1pm 7.5 14.7 22.0 fps Pipe Support ) (turnished by customer) t for valve weight only. VerJcaJ Qentatn Z-PaUew" Flow Curve Z Standard 0rierTtaorI "N-Pattern" Row Curve N 311 LFB76V Psi Service Flow Rated Flow UL Rated Flow 22 20 18 18 r ________ 12 10 HH 0 50 100 150 200 250 300 350 400 450 500 gpm 379 757 1136 1514 1pm 75 . its 22.0 Ips 4" pal LF876V Service Flow Rated Flow U1. Rated Flow 18 18 14 I 12 10 0 100 379 200 300 400 1136 715 500 600 1893 12.8 700 800gpm 2650 1pm 19.1 fps A WAfl'S Brand ES-F-LF876V 2015 USA 1 (800) 767-1234 • F: (800) 788-4491 • rFecoonline.com Canada T (888) 208-8927 • F: (888) 479-2887 • F5500onIine.ca Latin America: T: (52) 55-4122-0138 • FEacoon/inecom 0 2019 FEBCO HYDRAULIC CALCULATIONS for Job Information Project Name: The Beacon - Building C (Rev. 1) Contract No. : 21176 City: Carlsbad, California 92009 Project Location: 7750 El Camino Real Date: 4/12/2021 Contractor Information Name of Contractor: Titan Fire Protection Address: 1341 Distribution Way City: Vista, CA 92081 Phone Number: E-mail: Name of Designer: JCR Authority Having Jurisdiction: City of Carlsbad Design Remote Area Name 1 Remote Area Location 2nd Floor Office Occupancy Classification Light Density (gpm/ft2) 0.116 Area of Application (ft2) 1586 Coverage per Sprinkler (ft2) 128 Number of Calculated Sprinklers 16 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 100 Total Water Required (incl. Hose Streams) (gpm) 375 Required Pressure at Source (psi) 127.6 Type of System Wet Volume - Entire System (gal) 7586.4 gal Water Supply Information Date 03-08-21 Location 7720 El Camino Real Source Wi Notes 10% CUSHION TAKEN OFF FLOW TEST. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 Job: The Beacon - Building C (Rev. 1) Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1: Wi Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 150.3 1696 128.3 Node at Source Static Pressure I Residual Pressure Flow I I I Available I Pressure I I Total Demand I I Required Pressure (psi) I (psi) (gpm) I I (psi) I (gpm) I (psi) Wi 150.3 128.3 1696 149 375 127.6 Hoses Inside Hose Flow I Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) 100 Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 100 Sprinklers Ovehead Sprinkler Flow (gpm) 275 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 275 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 118.7 BOR -Flow (gpm) 275 Demand w/o System Pump(s) N/A File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job The Beacon - Building C (Rev.1) Hydraulic Analysis for: I 1 0 Supply a System Demand CJ Add. Out. Hose 0 AvailableAt Source Li - ILJF.I1th-m'Tr- i&if Psi Ca ijMEN INS ]}_ fu L rsit 1 hf iL1 Jft["uf:Thi IIIIML w1jr'jT' !LiU]FiH — 1!T Lu.iJ1ihriP. n is i'JlT:i'i .1ui D Tff'1 JL]IIjiL1 k a. ,I'ZaIeAaIs;I.I.Ii'iDIIIs [iI. !ZeDKIsI. I-I File: Beacon Building C FP Plans.dwg Page 3 Date 7/14/2021 Copyright 2002-2012 Tyco Fire Protection Products Job The Beacon - Building C (Rev.1) Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 -Static 0 150.3 S2 Supply point #2-Residual 1696 128.3 Dl Elevation Pressure 0 12.6 D2 System Demand 275 127.6 D3 System Demand + Add.Out.Hose 375 127.6 Curve Intersections & Safety Margins Curve Name Intersection I I Safety Margin I Pressure (psi) I Flow (gpm) I Pressure ow (gpm) I Supply 149.4 302.1 21.4 1 375 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) siol Overhead Sprinkler 128 5.6 0.1 12.8 7 0.116 14.8 7 S102 Overhead 128 5.6 0.1 12.8 7 0.117 15 7.1 Sprinkler S103 Overhead 128 5.6 0.1 12.8 7 0.121 15.4 7.6 Sprinkler S104 Overhead 128 5.6 0.1 12.8 7 0.126 16.2 8.4 Sprinkler S105 Overhead 128 5.6 0.1 12.8 7 0.14 17.9 10.3 Sprinkler S106 Overhead 128 5.6 0.1 12.8 7 0.117 15 7.2 Sprinkler S107 Overhead 128 5.6 0.1 12.8 7 0.119 15.2 7.3 Sprinkler S108 Overhead 128 5.6 0.1 12.8 7 0.122 15.7 7.8 Sprinkler S109 Overhead 128 5.6 0.1 12.8 7 0.128 16.4 8.6 Sprinkler 5110 Overhead 128 5.6 0.1 12.8 7 0.142 18.2 10.6 Sprinkler Sill Overhead 128 5.6 0.1 12.8 7 0.143 18.3 10.6 Sprinkler S112 Overhead 128 5.6 0.1 12.8 7 0.144 18.5 10.9 Sprinkler S113 Overhead 128 5.6 0.1 12.8 7 0.15 19.2 11.7 Sprinkler File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 4 S114 Overhead Sprinkler 128 5.6 0.1 12.8 7 0.151 19.4 11.9 Overhead Sprinkler 128 5.6 0.1 12.8 7 0.153 19.6 12.2 S116 Overhead Sprinkler 128 5.6 0.1 12.8 7 0.159 20.3 13.1 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/ps11/2 ft ft psi ft2 ft S S1O1 HEAD 5.6 25 142.23 Overhead Sprinkler 128 862.11 S102 HEAD 5.6 25 142.23 Overhead Sprinkler 128 852.61 S106 HEAD 5.6 25 152.23 Overhead Sprinkler 128 862.11 S107 HEAD 5.6 25 152.23 Overhead Sprinkler 128 852.61 S103 HEAD 5.6 25 142.23 Overhead Sprinkler 128 844.11 S108 HEAD 5.6 25 152.23 Overhead Sprinkler 128 844.11 S104 HEAD 5.6 25 142.23 Overhead Sprinkler 128 837.66 S109 HEAD 5.6 25 152.23 Overhead Sprinkler 128 837.66 S105 HEAD 5.6 25 142.23 Overhead Sprinkler 128 828.41 Silo HEAD 5.6 25 152.23 Overhead Sprinkler 128 828.41 Sill HEAD 5.6 25 163.23 Overhead Sprinkler 128 862.53 S112 HEAD 5.6 25 163.23 Overhead Sprinkler 128 852.53 S113 HEAD 5.6 25 163.23 Overhead Sprinkler 128 841.86 S114 HEAD 5.6 25 173.23 Overhead Sprinkler 128 862.53 S115 HEAD 5.6 25 173.23 Overhead Sprinkler 128 852.53 S116 HEAD 5.6 25 173.23 Overhead Sprinkler 128 841.86 722 NODE 23.5 142.23 Node us.Tee 862.11 720 NODE 23.5 142.23 Node us.Tee 852.61 703 NODE 23.5 152.23 Node us.Tee 862.11 702 NODE 23.5 152.23 Node us.Tee 852.61 718 NODE 23.5 142.23 Node us.Tee 844.11 700 NODE 23.5 152.23 Node us.Tee 844.11 717 NODE 23.5 142.23 Node us.Tee 837.66 699 NODE 23.5 152.23 Node us.Tee 837.66 001 NODE 23.5 142.23 Node us.Tee 1 828.41 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations I Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev x Type Fitting Stat. Pres. Coverage y FD Time gpm/ps11/2 ft ft psi ft2 ft S 698 NODE 23.5 152.23 Node us.Tee 828.41 676 NODE 23.5 163.23 Node us.Tee 862.53 674 NODE 23.5 163.23 Node us.Tee 852.53 673 NODE 23.5 163.23 Node us.Tee 841.86 658 NODE 23.5 173.23 Node us.Tee 862.53 656 NODE 23.5 173.23 Node us.Tee 852.53 655 NODE 23.5 173.23 Node us.Tee 841.86 004 NODE 23.5 142.23 Node us.Tee 814.48 007 NODE 23.5 152.23 Node us.Tee 814.48 009 NODE 23.5 168.88 Node us.Tee 814.48 010 NODE j 23.5 180.46 Node us.Tee 814.48 024 NODE 23.5 261.77 Node us.Tee 814.48 054 NODE 10 277.71 Node us.Tee 890.25 045 NODE 10 245.27 Node us.Tee 890.25 064 NODE 10 254.62 Node us.Tee 949.58 BFV-O NODE 2.92 254.63 Node 952.25 BFV-I NODE 2.6 254.63 Node 952.25 BFP-I NODE 2 263.31 Node 958.34 BOR NODE 1 254.63 Node 952.25 078 NODE -4 254.63 Node us.90 952.25 079 NODE -4 262.65 Node us.90 958.69 BFP-O NODE 2 266.79 Node 956.54 083 NODE -4 267.45 Node us.90 956.19 407 NODE -4 277.53 Node us.Tee 975.58 420 NODE 1 -4 1 348.18 Node us.Tee 948.58 File: Beacon Building C FP Plansdwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/psi1/2 ft ft psi ft2 ft S 413 NODE -4 -428.1 Node us.Tee 1067.22 418 NODE -4 346.96 Node us.Tee 785.6 Wi SUPPLY -4 347.46 Supply 785.62 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiV2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I S101 25 5.6 14.8 1 lx(us.Tee-Br)=5 1.5 120 7 722 23.5 14.8 1.049 5 0.0744 0.6 6.5 0.5 722 23.5 0 1.25 9.5 120 8.1 720 23.5 14.8 1.442 0 0.0158 0 9.5 0.2 720 23.5 15 1.25 8.5 120 8.3 718 23.5 29.8 1.442 0 0.0576 0 8.5 0.5 718 23.5 15.4 1.25 6.46 120 8.8 717 23.5 45.2 1.442 0 0.1247 0 6.46 0.8 717 23.5 16.2 1.25 9.25 120 9.6 001 23.5 61.4 1.442 0 0.2199 0 9.25 2 001 23.5 17.9 1.25 lx(us.Tee-Br)=7.43 13.92 120 11.6 004 23.5 79.4 1.442 7.43 0.3535 0 21.35 7.5 004 23.5 0 2 10 120 19.2 007 23.5 79.4 2.157 0 0.0497 0 10 0.5 007 23.5 80.5 2 16.65 120 19.7 009 23.5 159.8 2.157 0 0.1819 0 16.65 3 009 23.5 55.9 2 11.58 120 22.7 010 23.5 215.7 2.157 0 0.317 0 11.58 3.7 010 23.5 59.2 2 lx(us.Tee-Br)=12.31 81.31 120 26.4 024 23.5 275 2.157 12.31 0.4968 0 93.62 46.5 024 23.5 0 2.5 5x(us.90)=41.19 118.7 120 72.9 054 10 275 2.635 41.19 0.1874 5.8 159.88 30 054 10 -110.4 3 2x(us.Tee-Br)=40.32 82.42 120 108.7 064 10 164.5 3.26 3x(us.90)=28.22 68.54 0.0257 0 150.96 3.9 064 10 110.4 3 lx(us.90)=9.41 9.74 120 112.6 BFV-O 2.92 275 3.26 9.41 0.0665 3.1 19.15 1.3 BFV-O 2.92 0 3 0.32 116.9 BFV-N BFV-I 2.6 275 0 0 2.7241 0.1 'K 0.32 0.9 BR/-I 2.6 0 3 1.6 120 117.9 BOR 1 275 3.26 0 0.0665 0.7 1.6 0.1 BOR 1 0 6 lx(us.90)=24.19 5 140 118.7 078 -4 275 6.4 24.19 0.0019 2.2 29.19 0.1 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright @2002-2012 Tyco Fire Protection Products Page 9 Job : The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pt) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 078 -4 0 6 lx(us.90)=21.4 10.29 150 120.9 079 -4 275 6.08 21.4 0.0021 0 31.69 0.1 079 -4 0 6 lx(us.90)=24.19 8.71 140 121 BFP-I 2 275 6.4 24.19 0.0019 -2.6 32.9 0.1 BFP-I 2 0 6 3.92 118.5 Watts BFP-O 2 275 0 0 1.5787 0 709DCDA 3.92 6.2 *** BFP-O 2 0 6 2x(us.90)=48.39 6.75 140 124.6 083 -4 275 6.4 48.39 0.0019 2.6 55.14 0.1 083 -4 0 6 lx(us.Tee-Br)=45.85 21.85 150 127.3 407 -4 275 6.08 45.85 0.0021 0 67.7 0.1 407 -4 -81.7 10 lx(us.Tee-Br)=81.94 76.83 140 127.5 420 -4 193.2 10.58 lx(elbow.22.5)=9.01 90.95 0.0001 0 167.78 0.0 420 -4 0 8 lx(us.Tee-Br)=61.64 163.09 140 127.5 418 -4 193.2 8.55 lx(elbow.22.5)=7.93 69.56 0.0002 0 232.65 0.1 418 -4 81.7 8 0.5 140 127.6 Wi -4 275 8.55 0 0.0005 0 ______ 0.5 0 W 127.6 Path No: 2 S102 25 5.6 15 1 lx(us.Tee-Br)=5 1.5 120 7.1 720 23.5 15 1.049 5 0.0758 0.6 6.5 0.5 720 8.3 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 10 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 3 S106 25 5.6 15 1 lx(us.Tee-Br)=5 1.5 120 7.2 703 23.5 15 1.049 5 0.0763 0.6 6.5 0.5 703 23.5 0 1.25 9.5 120 8.3 702 23.5 15 1.442 0 0.0162 0 9.5 0.2 702 23.5 15.2 1.25 8.5 120 8.5 700 23.5 30.2 1.442 0 0.0591 0 8.5 0.5 700 23.5 15.7 1.25 6.46 120 9 699 23.5 45.9 1.442 0 0.128 0 6.46 0.8 699 23.5 16.4 1.25 9.25 120 9.8 698 23.5 62.3 1.442 0 0.2256 0 9.25 2.1 698 23.5 18.2 1.25 lx(us.Tee-Br)=7.43 13.92 120 11.9 007 23.5 80.5 1.442 7.43 0.3627 0 ______ 21.35 7.7 007 19.7 Path No: 4 S107 25 5.6 15.2 1 lx(us.Tee-Br)=5 1.5 120 7.3 702 23.5 15.2 1.049 5 0.0778 0.6 6.5 0.5 702 8.5 Path No: 5 S103 25 5.61 15.4 1 lx(us.Tee-Br)=5 1.5 120 7.6 718 23.5 15.4 1.049 5 0.0803 0.6 6.5 0.5 718 8.8 Path No: 6 S108 25 5.6 15.7 1 lx(us.Tee-Br)=5 1.5 120 7.8 700 23.5 15.7 1.049 5 0.0824 0.6 6.5 0.5 700 9 Path No: 7 5104 25 5.6 16.2 1 lx(us.Tee-Br)=5 1.5 120 8.4 717 23.5 16.2 1.049 5 0.0877 0.6 6.5 0.6 717 9.6 File: Beacon Building C FP Plans.dwg Date 7/14/2021 copyright © 2002-2012 Tyco Fire Protection Products Page 11 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiY2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 8 Slog 25 5.6 16.4 1 lx(us.Tee-Br)=5 1.5 120 8.6 699 23.5 16.4 1.049 5 0.0899 0.6 6.5 0.6 699 9.8 Path No: 9 S105 25 5.6 17.9 1 lx(us.Tee-Br)=5 1.5 120 10.3 001 23.5 17.9 1.049 5 0.1061 0.6 001 11.6 Path No: 10 5110 25 5.6 18.2 1 lx(us.Tee-Br)=5 1.5 120 10.6 698 23.5 18.2 1.049 5 0.1088 0.6 6.5 0.7 698 11.9 Path No: 11 Sill 25 5.6 18.3 1 lx(us.Tee-Br)=5 1.5 120 10.6 676 23.5 18.3 1.049 5 0.1097 0.6 6.5 0.7 676 23.5 0 1.25 10 120 12 674 23.5 18.3 1.442 0 0.0233 0 10 0.2 674 23.5 18.5 1.25 10.67 120 12.2 673 23.5 36.7 1.442 0 0.0849 0 10.67 0.9 673 23.5 19.2 1.25 2x(us.Tee-Br)=14.86 33.02 120 13.1 009 23.5 55.9 1.442 lx(us.90)=3.72 18.58 0.1848 0 ______ 51.6 9.5 009 22.7 Path No: 12 5112 25 5.61 18.5 1 lx(us.Tee-Br)=5 1.5 120 10.9 674 23.5 18.5 1.049 5 0.1118 0.6 6.5 0.7 674 12.2 Path No: 13 S113 25 5.6 19.2 1 lx(us.Tee-Br)=5 1.5 120 11.7 673 23.5 19.2 1.049 5 6.51 0.1199 1 0.6 0.8 673 13.1 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 12 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 14 S114 25 5.6 19.4 1 lx(us.Tee-Br)=5 1.5 120 11.9 658 23.5 19.4 1.049 5 0.1221 0.6 6.5 0.8 658 23.5 0 1.25 10 120 13.4 656 23.5 19.4 1.442 0 0.0259 0 10 0.3 656 23.5 19.6 1.25 10.67 120 13.7 655 23.5 38.9 1.442 0 0.0945 0 10.67 1 655 23.5 20.3 1.25 lx(us.Tee-Br)=7.43 34.6 120 14.7 010 23.5 59.2 1.442 4x(us.90)=14.86 22.3 0.2056 0 ______ 56.9 11.7 010 26.4 Path No: 15 S115 25 5.6 19.6 1 lx(us.Tee-Br)=5 1.5 120 12.2 656 23.5 19.6 1.049 5 0.1244 0.6 6.5 0.8 656 13.7 Path No: 16 S116 25 5.6 20.3 1 lx(us.Tee-Br)=5 1.5 120 13.1 655 23.5 20.3 1.049 5 0.1333 0.6 6.5 0.9 655 14.7 Path No: 17 054 10 0 3 lx(us.Tee-Br)=20.16 32.44 120 108.7 045 10 110.4 3.26 20.16 0.0123 0 52.59 0.6 045 10 0 2.5 1x(us.Tee-Br)=16.47 68.69 120 109.3 064 10 110.4 2.635 lx(us.90)=8.24 24.71 0.0346 0 93.41 3.2 064 112.6 Path No: 18 407 413 -4 -4 0 81.7 10 10.58 lx(us.Tee-Br)=81.94 3x(elbow.22.5)=27.04 720.62 108.98 829.6 140 0.0000 127.5 0 0.0 413 -4 0 8 1x(us.Tee-Br)=61.64 1081.2 140 127.5 418 -4 81.7 8.55 9 0.0000 0 61.64 0.1 1142.9 3 418 127.6 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 13 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 24.14 ft/s occurs in the following pipe(s): (024-010) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 14 HYDRAULIC CALCULATIONS for Job Information Project Name: The Beacon - Building C (Rev. 1) Contract No. :21176 City: Carlsbad, California 92009 Project Location: 7750 El Camino Real Date: 4/12/2021 Contractor Information Name of Contractor: Titan Fire Protection Address: 1341 Distribution Way City: Vista, CA 92081 Phone Number: E-mail: Name of Designer: JCR Authority Having Jurisdiction: City of Carlsbad Design Remote Area Name 2 Remote Area Location 1st Floor Retail Occupancy Classification OH, G2 Density (gpm/ft2) 0.2 Area of Application (ft2) 1535 Coverage per Sprinkler (ft2) 123 Number of Calculated Sprinklers 13 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 250 Total Water Required (incl. Hose Streams) (gpm) 591.7 Required Pressure at Source (psi) 137.6 Type of System Wet Volume - Entire System (gal) 7605.8 gal Water Supply Information Date 03-08-21 Location 7720 El Camino Real Source WI Notes 10% CUSHION TAKEN OFF FLOW TEST. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 Job: The Beacon - Building C (Rev. 1) Hydraulic Analysis for: 2 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lbs/ft2) Water Supply Parameters Supply I: WI Supply Analysis Demand Hazen-Williams Water © 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 150.3 1696 128.3 Node at Source Static Pressure I Residual Pressure I I Flow I I I Available A bl il I Pressure I I Total Demand I I Required Pressure I (psi) I (psi) I (gpm) I I (psi) I (gpm) I (psi) Wi 150.3 128.3 1696 147.2 591.7 137.6 Hoses Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) 250 Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 250 Sprinklers Ovehead Sprinkler Flow (gpm) 341.7 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 341.7 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 128.6 BOR -Flow (gpm) 341.7 Demand w/o System Pump(s) N/A File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: The Beacon Building C (Revi) Hydraulic Analysis for: 2 )1y 0 System Demand -a-Add. Out. Hose 0 AvailableAt 147.2 psi ii Jfl I I so LIJi±LTIIi2. 'UI! &I'' L'1T ,i'J LIP1 ii MONISM Lim .ni :.i ui a ai.a, as ;as ii ass a, as is ii Si .55 ii ;aa S SI File: Beacon Building C FP Plansdwg Page 3 Date 7/14/2021 Copyright 20O22012 Tyco Fire Protection Products Job: The Beacon - Building C (Rev. 1) Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 -Static 0 150.3 S2 Supply point #2 - Residual 1696 128.3 Di Elevation Pressure 0 7.4 D2 System Demand 341.7 137.6 D3 ISystem Demand + Add.Out.Hose 591.7 137.6 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I I Pressure (psi) I Flow (gpm) I Pressure (psi) @ Flow (gpm) I Supply 149.1 357.7 9.6 1 591.7 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) S201 Overhead Sprinkler 123 5.6 0.2 24.6 19.3 0.2 24.6 19.3 Overhead S202 Sprinkler 123 5.6 0.2 24.6 19.3 0.202 24.9 19.8 S203 Overhead 123 5.6 0.2 24.6 19.3 0.211 25.9 21.5 Sprinkler S204 Overhead 123 5.6 0.2 24.6 19.3 0.224 27.5 24.1 Sprinkler S205 Overhead 123 5.6 0.2 24.6 19.3 0.201 24.7 19.5 Sprinkler S206 Overhead Sprinkler 123 5.6 0.2 24.6 19.3 0.204 25 20 S207 Overhead 123 5.6 0.2 24.6 19.3 0.212 26.1 21.7 Sprinkler S208 Overhead 123 5.6 0.2 24.6 19.3 0.225 27.7 24.4 Sprinkler S209 Overhead 123 5.6 0.2 24.6 19.3 0.205 25.3 20.3 Sprinkler S210 Overhead 123 5.6 0.2 24.6 19.3 0.208 25.6 20.8 Sprinkler S211 Overhead 123 5.6 0.2 24.6 19.3 0.217 26.6 22.6 Sprinkler S212 Overhead 123 5.6 0.2 24.6 19.3 0.229 28.2 25.4 Sprinkler S213 Overhead 123 5.6 0.2 24.6 19.3 0.24 29.5 27.8 Sprinkler File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 4 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/ps1½ ft ft psi ft2 ft S S201 HEAD 5.6 13 15.37 Overhead Sprinkler 123 855 S205 HEAD 5.6 13 25.37 Overhead Sprinkler 123 855 S202 HEAD 5.6 13 15.37 Overhead Sprinkler 123 842.75 S206 HEAD 5.6 13 25.37 Overhead Sprinkler 123 842.75 S209 HEAD 5.6 1 13 35.37 Overhead Sprinkler 123 855 S210 HEAD 5.6 13 35.37 Overhead Sprinkler 123 842.75 S203 HEAD 5.6 13 15.37 Overhead Sprinkler 123 830.5 S207 HEAD 5.6 13 25.37 Overhead Sprinkler 123 830.5 S211 HEAD 5.6 13 35.37 Overhead Sprinkler 123 830.5 S204 HEAD 5.6 13 15.37 Overhead Sprinkler 123 818.25 S208 HEAD 5.6 13 25.37 Overhead Sprinkler 123 818.25 S212 HEAD 5.6 13 35.37 Overhead Sprinkler 123 818.25 S213 HEAD 5.6 13 45.37 Overhead Sprinkler 123 830.5 154 NODE 11.5 15.37 Node us.Tee 855 164 NODE 11.5 25.37 Node us.Tee 855 153 NODE 11.5 15.37 Node us.Tee 842.75 163 NODE 11.5 25.37 Node us.Tee 842.75 171 NODE 11.5 35.37 Node us.Tee 855 170 NODE 11.5 35.37 Node us.Tee 842.75 152 NODE 11.5 15.37 Node us.Tee 830.5 162 NODE 11.5 25.37 Node us.Tee 830.5 169 NODE 11.5 35.37 Node us.Tee 830.5 156 NODE 11.5 15.37 Node us.Tee 818.25 166 NODE 11.5 25.37 Node us.Tee 818.25 150 NODE 11.5 15.37 Node. us.Tee 826.79 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations I Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/psi1/2 ft ft psi ft2 ft S 149 NODE 11.5 25.37 Node us.Tee 826.79 173 NODE 11.5 35.37 Node us.Tee 818.25 148 NODE 11.5 35.37 Node us.Tee 826.79 176 NODE 11.5 45.37 Node us.Tee 830.5 146 NODE 11.5 45.37 Node us.Tee 826.79 045 NODE 10 245.27 Node us.Tee 890.25 054 NODE 10 277.71 Node us.Tee 890.25 064 NODE 10 254.62 Node us.Tee 949.58 BFV-O NODE 2.92 254.63 Node 952.25 BR/-I NODE 2.6 254.63 Node 952.25 BFP-I NODE 2 263.31 Node 958.34 BOR NODE 1 254.63 Node 952.25 078 NODE -4 254.63 Node us.90 952.25 079 NODE -4 262.65 Node us.90 958.69 BFP-O NODE 2 266.79 Node 956.54 083 NODE -4 267.45 Node us.90 956.19 407 NODE -4 277.53 Node us.Tee 975.58 420 NODE -4 348.18 Node us.Tee 948.58 413 NODE -4 -428.1 Node us.Tee 1067.22 418 NODE -4 346.96 Node us.Tee 785.6 Fsuip SUPPLY 347.46 ply -4 785.62 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job : The Beacon - Building C (Rev.1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I S201 13 5.6 24.6 1 lx(us.Tee-Br)=5 1.5 120 19.3 154 11.5 24.6 1.049 5 0.1903 0.6 6.5 1.2 154 11.5 0 1.25 12.25 120 21.2 153 11.5 24.6 1.442 0 0.0404 0 12.25 0.5 153 11.5 24.9 1.25 12.25 120 21.7 152 11.5 49.5 1.442 0 0.1475 0 12.25 1.8 152 11.5 25.9 1.25 lx(us.Tee-Br)=7.43 3.71 120 23.5 150 11.5 75.4 1.442 7.43 0.3219 0 11.14 3.6 150 11.5 27.5 2.5 10 120 27.1 149 11.5 102.9 2.635 0 0.0304 0 10 0.3 149 11.5 103.5 2.5 10 120 27.4 148 11.5 206.5 2.635 0 0.1103 0 10 1.1 148 11.5 105.7 2.5 10 120 28.5 146 11.5 312.2 2.635 0 0.2371 0 10 2.4 146 11.5 29.5 2.5 lx(us.Tee-Br)=16.47 264.86 120 30.8 045 10 341.7 2.635 2x(us.90)=16.47 32.95 0.2803 0.6 297.81 83.5 045 10 -159 3 2x(us.Tee-Br)=40.32 32.44 120 115 054 10 182.7 3.26 40.32 0.0312 0 72.75 2.3 054 10 0 3 lx(us.Tee-Br)=20.16 82.42 120 117.2 064 10 182.7 3.26 3x(us.90)=28.22 48.38 0.0312 0 130.8 1 4.1 064 10 159 3 lx(us.90)=9.41 9.74 120 121.3 BFV-0 2.92 341.7 3.26 9.41 0.0994 3.1 19.15 1.9 BFV-O 2.92 0 3 0.32 126.3 BFV-N BFV-I 2.6 341.7 0 0 4.2385 0.1 0.32 1.4 BFV-I 2.6 0 3 1.6 120 127.8 BOR 1 341.7 3.26 0 0.0994 0.7 1.6 0.2 BOR 1 0 6 lx(us.90)=24.19 5 140 128.6 078 -4 341.7 6.4 24.19 0.0028 2.2 29.19 0.1 078 -4 0 6 lx(us.90)=21.4 10.29 150 130.9 079 -4 341.7 6.08 21.4 0.0032 0 31.69 0.1 079 -4 0 6 lx(us.90)=24.19 8.71 140 131 BFP-I 2 341.7 6.4 24.19 0.0028 -2.6 32.91 1 0.1 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I BFP-I 2 0 6 3.92 128.5 Watts BFP-O 2 341.7 0 0 1.5315 0 709DCDA 3.92 6 *** BFP-O 2 0 6 2x(us.90)=48.39 6.75 140 134.5 083 -4 341.7 6.4 48.39 0.0028 2.6 55.14 0.2 083 -4 0 6 lx(us.Tee-Br)=45.85 21.85 150 137.2 407 -4 341.7 6.08 45.85 0.0032 0 67.7 0.2 407 -4 -101.6 10 lx(us.Tee-Br)=81.94 76.83 140 137.4 420 -4 240.1 10.58 ix(elbow.22.5)=9.01 90.95 0.0001 0 167.78 0.0 420 -4 0 8 lx(us.Tee-Br)=61.64 163.09 140 137.5 418 -4 240.1 8.55 lx(elbow.22.5)=7.93 69.56 0.0004 0 232.65 0.1 418 -4 101.6 8 0.5 140 137.6 Wi -4 341.7 8.55 0 0.0007 0 0.5 0 Wi 137.6 Path No: 2 S205 13 5.6 24.7 1 ix(us.Tee-Br)=5 1.5 120 19.5 164 11.5 24.7 1.049 5 0.1923 0.6 6.5 1.3 164 11.5 0 1.25 12.25 120 21.4 163 11.5 24.7 1.442 0 0.0408 0 12.25 0.5 163 11.5 25 1.25 12.25 120 21.9 162 11.5 49.8 1.442 0 0.1491 0 12.25 1.8 162 11.5 26.1 1.25 lx(us.Tee-Br)=7.43 3.71 120 23.7 149 11.5 75.9 1.442 7.43 0.3254 0 11.141 1 3.6 149 27.4 Path No: 3 S202 13 5.61 24.9 1 1x(us.Tee-Br)=5 1.5 120 19.8 153 11.5 24.9 1.049 5 0.1945 0.6 6.5 1.3 153 21.7 Path No: 4 S206 13 5.6 25 1 ix(us.Tee-Br)=5 1.5 120 20 163 11.5 25 1.049 5 0.1966 0.6 6.5 1.3 163 21.9 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 8 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 5 S209 13 5.6 25.3 1 lx(us.Tee-Br)=5 1.5 120 20.3 171 11.5 25.3 1.049 5 0.1998 0.6 6.5 1.3 171 11.5 0 1.25 12.25 120 22.3 170 11.5 25.3 1.442 0 0.0424 0 12.25 0.5 170 11.5 25.6 1.25 12.25 120 22.8 169 11.5 50.8 1.442 0 0.1549 0 12.25 1.9 169 11.5 26.6 1.25 1x(us.Tee-Br)=7.43 3.71 120 24.7 148 11.5 77.5 1.442 7.43 0.338 0 11.141 3.8 148 28.5 Path No: 6 S210 13 5.61 25.6 1 lx(us.Tee-Br)=5 1.5 120 20.8 170 11.5 25.6 1.049 5 0.2043 0.6 6.5 1.3 170 22.8 Path No: 7 S203 13 5.6 25.9 1 lx(us.Tee-Br)=5 1.5 120 21.5 152 11.5 25.9 1.049 5 0.21 0.6 6.5 1.4 152 23.5 Path No: 8 S207 13 5.6 26.1 1 lx(us.Tee-Br)=5 1.5 120 21.7 162 11.5 26.1 1.049 5 0.2123 0.6 6.5 1.4 162 23.7 Path No: 9 S211 13 5.61 26.6 1 lx(us.Tee-Br)=5 1.5 120 22.6 169 11.5 26.6 1.049 5 0.2205 0.6 6.5 1.4 169 24.7 Path No: 10 S204 13 5.6 27.5 1 lx(us.Tee-Br)=5 1.5 120 24.1 156 11.5 27.5 1.049 5 0.2338 0.6 6.5 1.5 156 11.5 0 1.25 lx(us.Tee-Br)=7.43 8.54 120 26.3 150 11.5 27.5 1.442 7.43 0.0496 0 15.981 0.8 150 27.1 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 9 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pt) (ft) (gpm/psil/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 11 S208 13 5.6 27.7 1 lx(us.Tee-Br)=5 1.5 120 24.4 166 11.5 27.7 1.049 5 0.2363 0.6 6.5 1.5 166 11.5 0 1.25 lx(us.Tee-Br)=7.43 8.54 120 26.6 149 11.5 27.7 1.442 7.43 0.0502 0 15.98 0.8 149 27.4 Path No: 12 S212 13 5.6 28.2 1 lx(us.Tee-Br)=5 1.5 120 25.4 173 11.5 28.2 1.049 5 0.2454 0.6 6.5 1.6 173 11.5 0 1.25 lx(us.Tee-Br)=7.43 8.54 120 27.6 148 11.5 28.2 1.442 7.43 0.0521 0 15.981 0.8 148 28.5 Path No: 13 5213 13 5.6 29.5 1 lx(us.Tee-Br)=5 1.5 120 27.8 176 11.5 29.5 1.049 5 0.267 0.6 6.5 1.7 176 11.5 0 1.25 lx(us.Tee-Br)=7.43 3.71 120 30.2 146 11.5 29.5 1.442 7.43 0.0567 0 11.141 1 0.6 146 30.8 Path No: 14 045 10 0 2.5 1x(us.Tee-Br)=16.47 68.69 120 115 064 10 159 2.635 lx(us.90)=8.24 24.71 0.068 0 93.4 6.3 064 121.3 Path No: 15 407 413 -4 -4 0 101.6 10 10.58 lx(us.Tee-Br)=81.94 3x(elbow.22.5)=27.04 720.62 108.98 829.6 140 0.0000 137.4 0 0.0 413 -4 0 8 lx(us.Tee-Br)=61.64 1081.2 140 137.5 418 -4 101.6 8.55 9 0.0001 0 61.64 0.1 1142.9 3 418 137.6 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 10 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 20.1 ft/s occurs in the following pipe(s): (045-146) "f" Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 11 HYDRAULIC CALCULATIONS for Job Information Project Name: The Beacon - Building C (Rev. 1) Contract No. :21176 City: Carlsbad, California 92009 Project Location: 7750 El Camino Real Date: 4/12/2021 Contractor Information Name of Contractor: Titan Fire Protection Address: 1341 Distribution Way City: Vista, CA 92081 Phone Number: E-mail: Name of Designer: JCR Authority Having Jurisdiction: City of Carlsbad Design Remote Area Name 3 Remote Area Location Exterior Hallway Occupancy Classification Light Density (gpm/ft2) 0.138 Area of Application (ft2) 749 Coverage per Sprinkler (ft2) 107 Number of Calculated Sprinklers 7 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 100 Total Water Required (incl. Hose Streams) (gpm) 231.7 Required Pressure at Source (psi) 117.6 Type of System Wet Volume - Entire System (gal) 7583.2 gal Water Supply Information Date 03-08-21 Location 7720 El Camino Real Source Wi Notes 10% CUSHION TAKEN OFF FLOW TEST. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 Job: The Beacon - Building C (Rev. 1) Hydraulic Analysis for: 3 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1: Wi Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 150.3 1696 128.3 I Static Pressure I Residual I ow Fl I Available I I I Total Demand I Required Pressure Node at Source (psi) I Pressure I (gpm) Pressure I I (gpm) I (psi) (psi) I (psi) I Wi 150.3 128.3 1696 149.7 231.7 117.6 Hoses Inside Hose Flow I Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) 100 Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 100 Sprinklers Ovehead Sprinkler Flow (gpm) 131.7 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 131.7 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 107.3 BOR -Flow (gpm) 131.7 Demand w/o System Pump(s) N/A File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job: The Beacon Budding C (Revi) Hydraulic Analysis for: 3 J Supply .0 System Demand .0 Add. Out. Hose 0 AvaflableAt Source 111IMEMEMEMMMMMM Ii Ili on 1111110 mom MM 1111100 II • h.{1. 1111Hr 1111110 LJJUUJL1 jJJ 1' irrP = Ti 41 IS .55 II ;I, •S. III IS II II SI •SI SI SS! I II File: Beacon Building C FP Plansdwg Date 7/14/2021 copyrightei 2002-2012 Tyco Fire Protection Products Page 3 Job: The Beacon - Building C (Rev. 1) Hydraulic Analysis for: 3 Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 - Static 0 150.3 S2 Supply point #2 - Residual 1696 128.3 Dl Elevation Pressure 0 5.9 D2 System Demand 131.7 117.6 D3 System Demand + Add.Out.Hose 231.7 117.6 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I Pressure (psi) I Flow (gpm) I I Pressure (psi) I I © Flow (gpm) I Supply 150 151.2 32.1 1 231.7 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) S301 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.138 14.8 7 S302 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.14 15 7.1 S303 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.148 15.9 8 S304 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.161 17.2 9.5 S305 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.182 19.4 12 S306 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.211 22.6 16.3 S307 Overhead Sprinkler 107 5.6 0.1 10.7 7 0.251 26.8 23 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 4 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/psi1/2 ft ft psi ft2 ft S301 HEAD 5.6 9.5 15.75 Overhead Sprinkler 107 866.22 S302 HEAD 5.6 9.5 24.75 Overhead Sprinkler 107 866.22 S303 HEAD 5.6 9.5 30.93 Overhead Sprinkler 107 866.22 S304 HEAD 5.6 9.5 42.94 Overhead Sprinkler 107 866.22 S305 HEAD 5.6 9.5 54.94 Overhead Sprinkler 107 866.22 S306 HEAD 5.6 9.5 66.94 Overhead Sprinkler 107 866.22 S307 HEAD 5.6 9.5 78.94 Overhead Sprinkler 107 866.22 002 NODE 12.83 15.75 Node us.Tee 866.22 006 NODE 12.83 24.75 Node us.Tee 866.22 011 NODE 11.5 30.93 Node us.Tee 866.22 012 NODE 11.5 42.94 Node us.Tee 866.22 013 NODE 11.5 54.94 Node us.Tee 866.22 014 NODE 11.5 66.94 Node us.Tee 866.22 015 NODE 11.5 78.94 Node us.Tee 866.22 138 NODE 11.5 97.21 Node us.Tee 826.79 045 NODE 10 245.27 Node us.Tee 890.25 054 NODE 10 277.71 Node us.Tee 890.25 064 NODE 10 254.62 Node us.Tee 949.58 BFV-O NODE 2.92 254.63 Node 952.25 "1' NODE 2.6 254.63 Node 952.25 BFP-I NODE 2 263.31 Node 958.34 BOR NODE 1 254.63 Node 952.25 078 NODE -4 254.63 Node us.90 952.25 079 NODE -4 262.65 Node us.90 958.69 BFP-O NODE 2 1 266.79 Node 956.54 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 Job The Beacon - Building C (Rev.1) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y FD Time gpm/psil/2 ft ft psi ft2 ft S 083 NODE -4 267.45 Node us.90 956.19 407 NODE -4 277.53 Node us.Tee 975.58 420 NODE -4 348.18 Node us.Tee 948.58 413 NODE -4 -428.1 Node us.Tee 1067.22 418 NODE -4 346.96 Node us.Tee 785.6 Wi SUPPLY -4 347.46 Supply 785.62 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I S301 9.5 5.6 14.8 1 lx(us.Tee-Br)=5 3.33 120 7 002 12.83 14.8 1.049 5 0.0744 -1.4 8.33 0.6 002 12.83 0 1.25 9 120 6.2 006 12.83 14.8 1.442 0 0.0158 0 9 0.1 006 12.83 15 1.25 2x(us.90)=7.43 7.52 120 6.3 011 11.5 29.8 1.442 7.43 0.0575 0.6 14.95 0.9 011 11.5 15.9 1.25 12.01 120 7.8 012 11.5 45.6 1.442 0 0.1269 0 12.01 1.5 012 11.5 17.2 1.25 12 120 9.3 013 11.5 62.9 1.442 0 0.2296 0 12 2.8 013 11.5 19.4 1.25 12 120 12 014 11.5 82.3 1.442 0 0.3781 0 12 4.5 014 11.5 22.6 1.25 12 120 16.6 015 11.5 104.9 1.442 0 0.5927 0 12 7.1 015 11.5 26.8 1.25 2x(us.Tee-Br)=14.86 57.7 120 23.7 138 11.5 131.7 1.442 14.86 0.9039 0 72.56 65.6 138 11.5 0 2.5 lx(us.Tee-Br)=16.47 213.02 120 89.3 045 10 131.7 2.635 2x(us.90)=16.47 32.95 0.048 0.6 245.97 11.8 045 10 -61.3 3 2x(us.Tee-Br)=40.32 32.44 120 101.7 054 10 70.4 3.26 40.32 0.0053 0 72.75 0.4 054 10 0 3 lx(us.Tee-Br)=20.16 82.42 120 102.1 064 10 70.4 3.26 3x(us.90)=28.22 48.38 0.0053 0 130.8 0.7 064 10 61.3 3 lx(us.90)=9.41 9.74 120 102.8 BFV-0 2.92 131.7 3.26 9.41 0.017 3.1 19.15 0.3 BFV-O 2.92 0 3 0.32 106.2 BFV-N BR/-I 2.6 131.7 0 0 0.7767 0.1 *** 0.32 0.2 BR/-I 2.6 0 3 1.6 120 106.6 BOR 1 131.7 3.26 0 0.017 0.7 1.6 0.0 BOR 1 0 6 lx(us.90)=24.19 5 140 107.3 078 -4 131.7 6.4 24.19 0.0005 2.2 29.19 0.0 078 -4 0 6 lx(us.90)=21.4 10.29 150 109.5 079 -4 131.7 6.08 21.4 0.0005 0 31.69 0.0 File: Beacon Building C FP Plarts.dwg Date 7/14/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 079 -4 0 6 lx(us.90)=24.19 8.71 140 109.5 BFP-I 2 131.7 6.4 24.19 0.0005 -2.6 32.9 0.0 BFP-I 2 0 6 3.92 106.9 Watts BFP-O 2 131.7 0 0 2.0526 0 709DCDA 3.92 8 *** BFP-O 2 0 6 2x(us.90)=48.39 6.75 140 115 083 -4 131.7 6.4 48.39 0.0005 2.6 55.14 0.0 083 -4 0 6 ix(us.Tee-Br)=45.85 21.85 150 117.6 407 -4 131.7 6.08 45.85 0.0005 0 67.7 0.0 407 -4 -39.2 10 lx(us.Tee-Br)=81.94 76.83 140 117.6 420 -4 92.6 10.58 lx(elbow.22.5)=9.01 90.95 0.0000 0 167.78 0 420 -4 0 8 ix(us.Tee-Br)=61.64 163.09 140 117.6 418 -4 92.6 8.55 ix(elbow.22.5)=7.93 69.56 0.0001 0 232.65 0.0 418 -4 39.2 8 0.5 140 117.6 Wi -4 131.7 8.55 0 0.0001 0 0.5 0 Wi 117.6 Path No: 2 S302 9.5 5.6 15 1 ix(us.Tee-Br)=5 3.33 120 7.1 006 12.83 15 1.049 5 0.0757 -1.4 8.33 0.6 006 6.3 Path No: 3 5303 9.5 5.6 15.9 1 ix(us.Tee-Br)=5 2 120 8 011 11.5 15.9 1.049 5 0.0845 -0.9 7 0.6 011 7.8 Path No: 4 S304 9.5 5.6 17.2 1 ix(us.Tee-Br)=5 2 120 9.5 012 11.5 17.2 1.049 5 0.0983 -0.9 7 0.7 012 9.3 Path No: 5 S305 9.5 5.6 19.4 1 lx(us.Tee-Br)=5 2 120 12 013 11.5 19.4 1.049 5 0.1229 -0.9 7 0.9 013 12 File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 S Job The Beacon - Building C (Rev. 1) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 6 S306 9.5 5.6 22.6 1 1x(us.Tee-Br)=5 2 120 16.3 014 11.5 22.6 1.049 5 0.1627 -0.9 7 1.1 014 16.6 Path No: 7 S307 9.5 5.6 26.8 1 1x(us.Tee-Br)=5 2 120 23 015 11.5 26.8 1.049 5 0.2237 -0.9 7 1.6 015 23.7 Path No: 8 045 10 0 2.5 1x(us.Tee-Br)=16.47 68.69 120 101.7 064 10 61.3 2.635 lx(us.90)=8.24 24.71 0.0116 0 93.4 1.1 064 102.8 Path No: 9 407 413 -4 -4 0 39.2 10 10.58 lx(us.Tee-Br)=81.94 3x(elbow.22.5)=27.04 720.62 108.98 829.6 140 0 117.6 0 0 413 -4 0 8 lx(us.Tee-Br)=61.64 1081.2 140 117.6 418 -4 39.2 8.55 9 0.0000 0 61.64 0.0 1142.9 3 418 117.6 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 25.88 ft/s occurs in the following pipe(s): (138-015) Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Beacon Building C FP Plans.dwg Date 7/14/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 9 H C ffz~~K '-4 L—FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION MATERIAL SUBMITTAL BEACON BLDG. C 7750 EL CAMINO REAL CARLSBAD, CA. 92009 CONTRACT NO. 21176 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page F?! n E ffz~~K '4 L-FIRE PROTECTION Fire Protection Contractor - License #989280 TABLE OF CONTENTS SPRINKLERS OVERHEAD PIPE AND FITTINGS HANGERS AND SEISMIC VALVES OTHER 1341 Distribution Way, Suite 14 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page Page 1 of 4 ® MICROFAST® QUICK iQ 'RESPONSE UPRIGHT Vi I SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. ItWARNING: Cancer and Reproducdve Harm- www.P65Wamings.ca.gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast'5 Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/VV, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 2 of 4 J.10~ R MICROFAST® QUICK 11(1 l:II[iu.7f RESPONSE UPRIGHT SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient o Bulb Color U Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 C) Orange Ordinary 155 F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 F (93 C) 150 ¶ (65 °C) Green High 286 ¶ (141 C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes I The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap-------. Wrench Flat - Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 18.10.11 Rev 17.1.P65 Page 3 of 4 2.R; MICROFAST® QUICK I( I'J ri l:II[1u.rM RESPONSE UPRIGHT •• 1• 'I% SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Terrpe:tu'e KEY MicrofastO Quick Response Pirish A1X4 Escutch€,c 'app cab's) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN Number' NPT BSP U.S. metric2 Inches mm cULus VdS I LPCB NYC8 CE 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, 132 -- -- See footnote 7. -- 06661B VK300 1/2" 1 15 mm 1 5.6 80.6 2-3/16 56 Al, B2 -- -- see footnote 7.1 -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200°F (93 °C), and I1A.1\ uu ' 1 - Brass, Chrome, White Polyester5'6, and Black Polyester56 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT' Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - _UL (Also refer to Approval Chart 1 above.) The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 4 of 4 MICROFAST® QUICK A D A A RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Microfast5 Quick Response M)( Finish 4 E fappUcabIe) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN (Refer also to Design Criteria below.) NPT =BSP U.S. metric2 Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 - 06661B VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 White Polyester", and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyesierl 2 - ENT' Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. V DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfase Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 1 of 7 N ® MIRAGE® STANDARD AND QR CONCEALED PENDENT I(iN SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- Ri profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approval: Class 2015 / WARNING: Cancer and Reproductive Harm- I NYC Approved: MEA 89-92-E, Volume 32 www.P65Warnings.ca.gov I VdS Approved: Certificate G4080021 OLKB LPCB Approved: Certificate number 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart I Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-530400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 OF (68 "C) = B, 175 OF (79 "C) = D, 200 OF (93 "C) = E For example, sprinkler VK463 with a 155 OF (68 °C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 OF (74 "C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 OF (57 °C) UL (139 OF (59 "C) FM and LPCB) = A, 165 OF (74 °C) = C For example, cover 21876 with a 165 OF (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 OF (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a V2' ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3 of 7 MIRAGE® STANDARD AND N 61 NCO QR CONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Nominal Ambient Cover Plate Large Cover Temperature Rating of Cover I Square Cover I Temperature Temperature Ceiling Base Part Plate Base Part Assembly (Required) Plate Base Part Bulb Color Classification Rating' Temperature2 Number3 Number3 Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135 °F (57 °C) cULus 13504 or 218765 13642 or 218751 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 21875 15394 1 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 21875 5 1 15394 1 Green Cover Plate Finishes5: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings': ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. \\ \!IKII° I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers , Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com r - - - SprinklerTemperature RatingApproval Chart I (UL) Cover Plate Temperature Rating Mirages Concealed Pendent Sprinklers VK462 and VK463 AWloVer Pale Finish KEY Sprinkler Thread Nominal Maximum Listings and Approvals4 SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' I Inch mm U.S. meU1c2 Pressure cULus' I NYC I VdS7 I LPCB I CE 12 Standard Response Applications 13503A VK462 1/2' - 5.6 80.6 175 psi (12 bar) -- -- AY1,CZ1 AY1,BZ1 AY1,CZ1' AY3 -- 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - -- - -- -- -- AY2, CZ2 21356A VK462 - 15 5.6 1 80.6 175 psi (12 bar) -- -- - -- -- -- AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1, BX16 - - -- AY3 -- __________ AS3, BT3 AV1, BX1, 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1' - - -- -- -- AS3, BT3 13667A VK463 1/2" 15 6 80.6 250p51(17.2 bar)' I AV1,BX1 I AV1,BX1' -- -- -- -- -- Cover Plate Assembly Temperature Ratings1'9 Sprinkler Temperature S - 135 "F (57 "C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings I - 165 °F (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A - 155 °F (68 °C) °F V - 135 (57 C) cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) Brass, Brushed Brass, Brushed Copper, Painted White, B - 175 "F (79 °C) and 200 ¶ x - 165 °F (74 °C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y - 135 °F (57 °C) cover 13504 LPCB Approved as 139 °F 2 - Brass C - 200 °F (93 "C) (59 °C) 3 - Stainless Steel Z - 165 °F (74 °C) cover 13504 Footnotes I Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 'CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139°F cover has an orange label. The 165 °F (74 °C) cover has a white label. '° Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 12 MED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F103005 18.10.11 Rev 18.2.P65 Page 5 of 7 A: MIRAGE" STANDARD AND QR CONCEALED PENDENT l:II[.qJuuyM SPRINKLER VK462 AND HP IQ NC; SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL - (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Aooroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 6017 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Sprinkler Temperature Rating - Cover Plate Temperature RaVng Miragea Standard Response Concealed Pendent Sprinkler VK462 .Awl* _Cover Plate Finish KEY -- Sprinkler Base NPT Thread Size Nominal K-Factor I I Maximum FM Approvals' Part No.' SIN I i I Water Working I (Refer also to Design Criteria below.) I Inch I mm U.S. I metric2 I Pressure 13503A VK462 1/2' 15 5.6 80.6 175 psi (l2bar) AW1, BX1, AY2, BZ2 Cover Plate Assembly Temperature Ratings14 Cover Plate Assembly Finishes' Y - 139°F (59 °C) cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175 °F (79 °C) and 200 °F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 2-1/4" (57 mm) diameter opening required in the ceiling. Page 7of7 MIRAGE STANDARD AND l.l:II[.q..u.7M QR CONCEALED PENDENT yj SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrench Part No. 14047WB** Step 1: Carefully slide the wrench sideways around the deflector and pins Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler and Adapter Assembly Protective cap removed Use wrench 14047WB** NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 112" ratchet is required (Not available from Viking) Sprinkler frame arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum / 2-1/16" (52 mm) \ Minimum ar o E un fl I I '4) SAM 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 14 's. ni ri MICROFAST®QUICK k Q 77 A RESPONSE HORIZONTAL IIl9I[ I IY SIDE WALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. LISTINGS AND APPROVALS c®us cULus Listed: Category VNlV <a> FM Approved: Class 2020 China Approval: Approved according to China GB Standard Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. WARNING: Cancer and Reproductive Harm- www.P65Warningsca.gov TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4" (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F / 57 °C = A, 155 °F / 68 °C = B, 175°F / 79 °C = D, 200 °F / 93 °C = E, and 286 °F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) **A 1/2" ratchet is required (not available from Viking). Form No. F_060914 19.11.21 Rev 19.2 Replaces form F_060914 Rev. 19.1 (Revised China approval.) Page 2 of 6 MICROFAST® QUICK l9I[iUI7f RESPONSE HORIZONTAL ' IQm IJ SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F060914 19.11.21 Rev 19.2 Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. Page 3 of 6 irn MICROFAST®QUICK 'I.II( l.I:II[iu.7Iv RESPONSE HORIZONTAL 'SIDEWALL SPRINKLER VK3 K The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature I I Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color U Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 OF (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. A 1/2" ratchet is required Step 2: Carefully press the wrench onto the (not available from Viking) sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers Form No. F060914 19.11.21 Rev 19.2 Page 4 of 6 Kj E.\ r MICROFAST®QUICK RESPONSE HORIZONTAL ' SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Tenperaue KEY 4', Finish Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 AIX4 Escutcheon app cable) For Light or Ordinary Hazard Occupancies Maximum 175 PSI (12 Bar) WWP Deflector must be located 4" to 12" (102 mm to 305 mm) below the ceiling. Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Base Part SIN (Refer also to UL Design Criteria.) Number' NPT BSPT U.S. metric2 Inches mm cULus4 China Approval 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z -- 197821 VK305 1/2" -- 5.6 80.6 2-11/16 68 E3 E3 12121 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z -- Approved Temperature Ratings A - 135 OF (57 "C), 155 OF (68 °C), 175 OF (79 °C), Approved Escutcheons 200 OF (93 'C), and 286 OF (141 °C) Approved Finishes W - Installed with standard surface-mounted escutcheons B - 135°F (57 'C), 155 OF (68 °C) 175°F (79 'C) 1 - Brass, Chrome, White Poly-ester56, X - Installed with standard surface-mounted escutch- and 200 OF (93 °C) and Black Polyester56 eons or recessed with the Viking Micromatic® Model C - 155°F (68 'C), 175 OF (79 °C), 200 OF (93 °C), 2 - ENT E-1, E-2, or G-1 Recessed Escutcheon and 286 OF (141 °C) Z - Installed with standard surface-mounted escutch- D - 155 OF (68 'C), 175 OF (79 'C), and 200 OF - Chrome eons or recessed with the Viking Micromatic Model (93 'C) E-1 E - 155 OF (68 °C) I Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Approved according to China GB Standard. DESIGN CRITERIA -UL (Also refer to Approval Chart 1.) cULus Listing Reguirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate with the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F060914 19.11.21 Rev 19.2 Page 5 of 6 MICROFAST® QUICK \ I 17 I RESPONSE HORIZONTAL i i l.II[sYIU.7..If. SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 'empera1ure KEY Fr sn Approval Chart I (FM) Escutcheon fappIrcabe) Microfast® Quick Response Sidewall Sprinklers Maximum 175 PSI WWP Sprinkler - Thread Size Nominal K-Factor Overall Length FM Approvals34 - Base Part SIN ___________________ NPT BSPT U.S. ________ metric2 Inches mm Number' (Refer also to Design Criteria below.) 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X 12121 VK305 1/2" 115 mm 1 5.6 80.6 1 2-11/16 68 AIW, B1X, C2W, D2Z -- Approved Temperature Ratings Approved Escutcheons X - Installed with standard surface-mounted escutch- A - 135 ¶ (57 AC), 155 °F (68 CC), 175 F (79 Approved Finishes eons or recessed with the Viking Micromatic® Model °C), 200 °F (93 °C), and 286 °F (141 °C) 1 - Brass E-1, E-2, E-3, or G-1 Recessed Escutcheon B - 135 °F (57 °C), 155 ¶ (68 °C), 175 ¶ (79 °C), V - Installed with standard surface-mounted escutch- and 200 oF (93 °C) eons Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. Approved according to China GB Standard. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F060914 19.11.21 Rev 19.2 Page 6 of 6 MICROFAST® QUICK VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 2-3/4" (68 mm) 2-7/16" (62 mm) I Wall Opening Size: Installed with a Standard 2-5/16" (58.7 mm) minimum 1/8" Surface-Mounted 2-1/2" (63.5 mm) maximum Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon Minimum 1-5/8" 44 f (41 mm) 17 2-1/8" (54 mm) 2-1/4" Minimum 1-3/4" (45 mm) H LE - 2-5/8" 2-1/8" ; (54 mm) (57 mm) (67 mm) Maximum Maximum Wall Opening Size: Installed with the Installed with the 2-5/16" (58.7 mm) minimum Micromatic Model E1 Threaded Model E-2 2-1/2" (63.5 mm) maximum Recessed Escutcheon Recessed Escutcheon Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_060914 19.11.21 Rev 19.2 Replaces form F_060914 Rev. 19.1 (Revised China approval.) Page 1 of 6 V w6j MICROFAST® QUICK iL RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 OF LPCB Approved: Certificate 096e106 WARNING: Cancer and Reproductive Harm- wwwP65Wamings.ca.gov CE CE: Standard EN 12259-1 ,Declaration of Performance DOP_Sprinklers_LPCB_5-2-19, DOP_VK302ENT_29-1-20 & DOP_VK302- 57C_30-9-20 China Approval: Approved according to China GB standard O MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Form No. F_033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.) Page 2 of 6 MICROFASPQUICK RESPONSE PENDENT 'U SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 20.07.14 Rev 20.1 Page 3 of 6 V\ flfl/7 J . R: MICROFAST® QUICK \4& l:II[.quqM RESPONSE PENDENT ! SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature 2 Bulb 0 or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. —®r l --.-- -o Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is require (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 20.07.14 Rev 20.1 Page 4 of 6 MICROFAST®QUICK RESPONSE PENDENT I SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) - - The Viking Microfaste Quick Response Temperature KEY - Firish Pendent Sprinkler VK302 AiX 4— Escutcheon (if applicable) Maximum 175 PSI(12 Bar) WWP Base Thread Size Nominal Overall Listings and Approvals3 K-Factor Length Criteria.) (Refer also to Design Crutea.) Part CrJ Style Number' NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB CE7 MED8 China Approval 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, 02, C2X Al A1Z, B1Y D1Z,C1Y,D2, oi AZ, BY 21354s 1 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 D3 -- -- -- -- D3 06662B VK302 Pendent 1/2' 15 mm 5.6 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- ~_Dl 18021 VK302 Pendent 1/2" 15mm 5.6 80.6 1 2-1/4 58 A1Z,B1Y Al I A1Z,BIY D1Z,C1Y,D2 -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 'C), 155 OF (68 'C), 175°F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 'C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B -135°F (57 °C), 155°F (68 °C), 175°F ter56 Y- Standard surface-mounted escutcheon or recessed with the Viking Micromatice (79 'C), and 200 OF (93 °C) 2 - ENT5 Model E-1, E-2, or E-3 Recessed Escutcheon C -155 OF (68 °C), 175 OF (79 °C), and 3-Chrome Z- Standard surface-mounted escutcheon 200 'F (93 'C) D - 155 OF (68 'C), 175 OF (79 °C), 200°F (93 °C), 286 OF (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE: Standard EN 12259-1, Declaration of Performance DOP_Sprinklers_LPCB_5-2-19, DOP_VK302ENT_29-1-20 & DOP_VK302-57C30-9-20. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. Approved according to China GB Standard. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfaste Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 20.07.14 Rev 20.1 Page 50f6 ® MICROFAST®QUICK n lII[Ui7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) r— Temperature KEY I I The Viking Microfast® Quick Response 'ç — Finsh Pendent Sprinkler VK302 I AIX 4— Escutcheon (if applicable)j Maximum 175 PSI (12 Bar) WWP Base Part I SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric2 Inches mm Number' I Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 213546 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 C3 06662B I VK302 1 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 ] Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y Approved Temperature Ratings - A - 135 "F (57 °C), 155 "F (68 °C), 175 F (79 SC), 200 °F Approved Escutcheons (93 °C), 286 °F (141 °C) Approved Finishes X - Standard surface-mounted escutcheon or the B - 135 "F (57 °C), 155 °F (68 CC), 175 °F (79 "C), and I -Brass, Chrome, White Polyester4, Viking Micromatic®Model E-1 Recessed Escutcheon 200 °F (93 °C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 "C), 286 2 - ENT' with the Viking Micromatic Model E-1 or E-2 "F (141 °C) 3 - Chrome Recessed Escutcheon D - 155 ¶ (68 °C), 175 °F (79 °C), 200 °F (93 "C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. 6 Approved according to China GB Standard. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM ADDroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 20.07.14 Rev 20.1 1-1/8" (29 mm) Mm. Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" T (29 mm) Mm. (51 mm) Max. Page 6 of 6 ' t® MICROFAST®QUICK J I lP l.4:II[.u'7M RESPONSE PENDENT V I I SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT\ (57mm) (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Iiiø- 2-1I8"... (54 mm) 1.34" - - (45 mm) Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking EC/QREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Pendent Sprinkler VK534 is cULus Listed as standard and quick response. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. 2. LISTINGS AND APPROVALS NOTE: As of May 2018 all logos have been re- moved from the wrench boss. WARNING: Cancer and Reproductive Harm- Specifications: www.P65Warnings.ca.gov Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-3/8" (61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinkler: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking EC/QREC Pendent Sprinkler VK534 by first adding the appropriate suffix for the sprinkler finish and then the appro- priate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 OF (57 °C) = A, 155 OF (68 °C) = B, 175 OF (79 °C) = D, 200 OF (93 °C) = E, and 286 OF (141 °C) = G For example, sprinkler VK534 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 08340AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available since 1981) Wrench for recessed pendent sprinkler: Part No. 11663W/B** (available since 2001) **A 1/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_051393 19.02.21 Rev 19.1 Replaces Form F_051393 Rev 18.2.P65 (Removed F-i Escutcheon.) cULus Listed: Category VNIV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. 3. TECHNICAL DATA Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking EC/QREC Pendent Sprinkler VK534 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_051393 19.02.21 Rev 19.1 Page 3o16 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data paqe www.vikinaqrouninc.com TABLE 1: AVAILABL PRINKILER TEMPERATURE RATINGS AND; HES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 °F (57 °C) 100 °F (38 C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester', Black Polyester', and ENT Corrosion-Resistant Coatings4: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT sprinklers, all exposed surfaces and the waterway are coated, but note that the spring is exposed. Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. - r __ •_____ Pendent Sprinkler Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. ** A 1/2" ratchet is required Step 2: Carefully press the wrench upward and (not available from Viking) ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK534 ig 1g0721 Rv11 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart I (UL) K SRIQR EC Pendent Sprinkler VK534 Sprinkler Base SIN NPT Thread Size I I Nominal K-Factor Maximum Water Overall Length I Inches I mm I U.S. I metric' Inches I mm Part Number' Working Pressure 08340 Pendent VK534 3/4 20 11.2 1 161.3 175 psi (12 Bar) 2-5/16 59 Minimum Water Supply Requirements' Listings and Approvals' Max. Sprinkler Maximum (Refer also to UL Design Spacing Area per Criteria) (L x W7) Sprinkler Light Hazard Ordinary Hazard Group I Ordinary Hazard Group Il Flow! Pressure Flow! Pressure Flow! Pressure cULus4 Standard Response 16 ft. x 16 ft. (4.9 256 ft2 (23.8 -- 38 gpm @ 11.5 psi 51 gpm @20.7 psi C1W, D1Y, D2Z, C2W mx 4.9 m) m2) (143.9 Umin @ .79 Bar) (193.1 Umin @ 1.43 Bar) 18 ft. x 18 ft. (5.5 324 ft2 (30.1 49 gpm @ 19.1 psi 65 gpm @ 33.7 psi C1W, D1Y, D2Z, C2W m 5.5 m) m2) -- (185.5 Umin @ 1.32 Bar) (246.1 Umin @2.32 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 m 2) 60 gpm @28.7 psi 80 gpm @ 51.0 psi C1W, D1Y, D2Z, C2W m 6.1 m) -- (227.1 Umin @ 1.98 Bar) (302.8 L/min @3.52 Bar) Quick Response 12 ft. x 12 ft. (3.7 144 ft2 30 gpm @7.2 psi 39 gpm @ 12.1 psi ElY, E2Z m x 3.7 m) (13.4 m2) -- (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 14 ft. x 14 ft. (4.3 196 ft2 30 gpm @ 7.2 psi 39 gpm @ 12.1 psi ElY, E2Z m x 4.3 m) (18.2 m2) -- (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 16 ft. x 16 ft. (4.9 256 ft2 (23.8 30 gpm @7.2 psi -- -- B1Y, F2Z m x 4.9 m) m2) (113.6 Umin @ .50 Bar) 18 ft. x 18 ft. (5.5 324 ft2 (30.1 33 gpm @ 8.7 psi (124.9 Li -- -- B1Y, F2Z m x 5.5 m) m2) mm @ .60 Bar) 20 ft. x 20 ft. (6.1 400 ft2 (37.2 40 gpm @ 12.8 psi (151.4 -- -- A1Y, G2Z m 6.1 m) m2) Umin @ .88 Bar) Approved Temperature Ratings A - 135 "F (57 °C) and 175°F (79 "C) Approved Escutcheons B - 135°F (57 °C), 155°F (68 °C), and 175°F (79 "C) Approved Finishes W - Standard surface-mounted escutcheons only C - 155 "F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 1 - Brass, Chrome, White Polyester, and Black Y - Standard surface-mounted escutcheons or the Microfast 286 °F (141 °C) Polyester Model F-i Adjustable Escutcheon, or recessed with the D - 155 °F (68 "C), 175 °F (79 "C), and 200 °F (93 °C) 2 - ENT' Micromatic® Model E-i, E-2, or E-3 Recessed Escutcheon E - 155 °F (68 "C) Z - Standard surface-mounted escutcheons or the Micromatic F - 155 °F (68 °C), and 175 °F (79 °C) Model E-i Recessed Escutcheon. G - 175°F (79 °C) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. cULus Listed for use in the U.S. and Canada. 5 To determine 'Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10-6" x 13-0° sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14-0° x 14-0" spacing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. 6 cULus Listed as corrosion-resistant. Form No. F_051393 19.02.21 Rev 19.1 Page 5of6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA -UL (Also refer to Approval Chart 1.) cULus Listing Requirements: EC-ELO Pendent Sprinkler VK534 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in Approval Chart I are designed to provide the following design densities: 0.10 gpm/ft2 (4.1 mm/mm) for Light Hazard densities; 0.15 gpm/ft2 (6.1 mm/mm) for Ordinary-Hazard Group I densities; 0.2 gpm/ft.2 (8.1 mm/mm) for Ordinary-Hazard Group II densities. The sprinkler installation rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. Viking EC-ELO Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. Ceiling slope not to exceed 2/12 (9•50) Also. Viking ECOH-ELO Pendent Sprinkler VK534 is specifically cULus Listed for Ordinary Hazard Occupancies: For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than 1" (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under "Obstructions to Sprinkler Discharge Pattern Development". For installation under concrete tees when installed as follows: The stems of the concrete tee construction must be spaced between 3 ft (0.9 m) and 7 ft-6 in (2.3 m) on center. The depth of the concrete tees must not exceed 30 in (762 mm). The maximum permitted concrete tee length is 32 ft (9.8 m). However, where the concrete tee length exceeds 32 It (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9.8 m). The sprinkler deflector is to be located in a horizontal plane at or above 1" (25.4 mm) below the bottom of the concrete tee stems. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_051393 19.02.21 Rev 19.1 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Ceiling Opening Size: 3/4 2-5/16" (59 mm) minimum (20 mm) 2-1/2" (64 mm) maximum NPT ' - ' ,, ,v. •.. - !.NIXIi\ (61; mm) 1-3/4" (45 mm) Installed with a standard (38 mm) 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon 2-1I8"--, (54 mm) r-i N 1-3/4" U (45 mm) Max. Installed with a Model E-1 Recessed Escutcheon 0 (54 mm) Installed with a Model E-2 Thread-on Recessed Escutcheon Ceiling Opening Size: 2-5116" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Mm. (29 mm) (51 mm) Mm. Max. -- Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 19.02.21 Rev 19.1 Replaces Form F_051393 Rev 18.2.P65 (Removed F-i Escutcheon.) FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe L I II IF wvam 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule niPipe ig-t B Le Si 1 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.260 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, 6 Chesterfield, MO 63017 contact your salesperson C®US (800) 325-4467 today at (800) 325-4467 or LISTED Q~1 , BULL. IWOSE TUBE C PANV FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada A(CAPARcompany e-mail: sa1es(.bu11moosetube.com call (800) 882-4666 <i > A= fl APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 NO. 20 TEE NO. 10 ELBOW ALTERNATE STYLES Victaulic offers a broad line of fittings in sizes through 60/1500mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange® adapters, check disc clearance dimensions with I.D. dimension of fitting. Note: The following Victaulic fittings are VdS approved: No.1090" Elbow, No. 11 45" Elbow, No.20 Tee and No.60 Cap. Note: The following Victaulic fittings are LPCB approved: No.10 90" Elbow, No.11 45" Elbow, No.12 22 ½" Elbow, No.13 111/4" Elbow, No.30 45" Lateral, No.30-R Reducing Lateral, No.100 Long Radius Elbow, No.110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Advanced Groove System - For 14— 60/350 - 1500 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8/25 - 200mm. Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel - A full range of fabricated segemtnally welded steel or full flow grooved end fittings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings - A full range of full flow fabricated fittings with Vic-Rings are also available. AGS - ADVANCED GROOVE SYSTEM Extra Heavy EndSeal® "ES" Fittings - EndSeal fittings are available in 2— 12'/50 - 300mm for use with "ES" grooved pipe and HP-70ES EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No, Submitted By Spec Sect Para Location Date Approved www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 vlCTAuuc COMPANY. ALL RIGHTS RESERVED. REV_R x.0A_Ct:8_U1id 0701.1 CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 4/20 - 100mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5-6/125 - 150mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or S, Gr. B 8— 127200-300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type E or S, Gr. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com \JtauIjc VICTAULIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 07.012 REVR CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/2 elbow is one-nail me resistance 01 a 45 elbow, values 01 mid-sizes can be 1.315 1.7 0.8 4.2 1.7 25 33.7 - ---'- 2.375 0.5 -4- - 3.5 - -- 2.5 ' 0.2 1 1.8 ------r- - --------- 1.1 1.3 ------------ 8.5 0.5 3.5 2 50 60.3 3.000 1.1 4 0.8 0.5 2.1 0.3 2.6 10.8 1.1 4.3 76.1 mm 761 3.500 4--43 1.3 - -- - -------- 5.0 - 3.8 0.7 2.6 - ----4--- ------. 1.6 3.3 13.0 _______ 1.3 5.0 3 80 88.9 4.250 1.5 6.4 1.2 0.8 3.2 0.5 4.0 15.3 1.5 6.4 108.0 mm 108.0 4.500 2.0 -4-. .- - - 6.8 E - 5.0 0.9 - 3.4 - - -.4- - - -----+--'- - 2.1 4.7 - - - .4- 16.0 2.0 6.8 4 100 114.3 5.250 2.1 +-.---.--I 8.1 1.5 1.0 4.1 I ---4---- 0.6 ----4-- 4.9 . ± 20.0 2.1 8.1 mm • 133.0 5.500 2,5 1-' -- 8.5 - 1.2 4.2 - -4--.- , - 6.2 --- .-+- 21.0 2.5 -. 8.5 mm • 139.7 - 5.563 2.6 4. - . - -- _4.___._._ 8.5 - - 1.3 - 4.2 - ,,_•. - 6.4 21.0 2.6 8.5 ___________ 5 125 141.3 6.250 2.6 9.4 - .-.------r--- . 4- ...--- 1.3 4.9 6.4 25.0 2.6 9.6 mm 159.0 6.500 2.9 9.6 - 1.5 - 5.0 - - - . - 7.6 25.0 2.9 10.0 mm - 165.1 - 6.625 - 2.9 ' - - 10.0 - 7.5 1.5 i 5.0 - ----+---------------- 3.0 7.6 --4----- 25.0 3.0 10.0 ____ 6 150 168.3 8.625 3.0 13.0 2.3 9.8 1.5 - 6.5 0.9 -- 4.0 7.6 33.0 3.0 13.0 8 200 10.750 219.1 - 4.0 - -4--.-- .- '-'-4---- - 17.0 3.0 12.0 - 2.0 8.3 1.2 5.0 --- 10.1 .4- 41.0 4.0 17.0 10 250 273.0 12.750 5.2 - 20.0 ' 3.7 14.5 -.--- ..---.----+- 2.5 10.0 1.5 6.0 .--.-.--.--+---... 12.5 50.0 - 5.2 20.0 12 300 323.9 14.000 6.1 24.5 § 4.4 15.8 - 3.0 18.5 § 1.8 11.0 15.2 - 70.0 6.1 23.0 14 350 355.6 16.000 7.5 28.05 4.8 18.0 5.6 - 21.05 3.4 - 13.0 21.3 - - 80.0 7.0 - - 27.0 16 400 406.4 18.000 8.5 -4--- - -4- --- 31.08 5.5 20.0 6.4 . 23.55 ,----f. 4.0 -,-- - - -4--- 14.0 24.4 -- - -- 90.0 8.2 -- 30.0 18 450 457.0 20.000 9.5 +-- - - - -1- 34.08 ' 6.1 22.5 ' 7.2 25.5 § 4.3 -4---- 16.0 27.4 - --- .4- 100.0 9.1 -- - 33.0 20 800 508.0 -- 24.000 10.4 -.--i--------.-4-_.__-_ 42.05 . 6.9 27.0 7.8 29.5 § -4------ I 4.9 - --.- -. , 19.0 - 30.5 - - - -4- - 120.0 10.1 -.- - - - 40.0 _______ 24 600 610.0 12.8 I 8.2 9.0 5.8 36.6 12.2 Fittings available up to 6011500 mm. Contact Victaulic for details. S Contact Victaulic for details. S For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14-24/350-600 mm size No, 10 and No. ii Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. W1 and No. Wi 1 Elbows), refer to submittal 20.05. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s". S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVR \4tauIic 07.013 FLOW DATA (Frictional Resistance) CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee bCtoE - CtoE NO. 25 Grooved Branch T NO. 29T Threaded Branch _ jftT C to to NO. 25 NO. 29T C to - to NO. 25-SW CtoE.1 Lo NO. 291-SW w =j 1 1 3/4 2.25sw 2.24 sw 1.0 25 < 20 57 2.75 5w - 57 2.75 sw 0.5 1.3 114 1¼ 1 32 32 25 70 2.75 sw --- 70 2.75 sw 0.6 1.5 1½ 11/2 Y4 X 40 40 20 70 70 07 - -- 1 2.75 sw 2.755w 1.5 25 70 70 0.7 - -. -+- 11/4 2.75 SW 2.75 sw 1.7 32 70 - 3.25 --i-- 70 3.25 0.8 2.5 2 2 Y4 x 50 50 x 20 83 83 1.1 1 3.25 ' 3.25 2,7 25 83 - 83 1.2 11/4 3.25sw -- 3.25 sw -. . -- 1.8 32 83 83 0.8 - ------ 11/2 3.25 3.25 sw 3.0 40 83 3.75 sw 83 3.75 sw 1.4-- 3.9 21/2 2½ 21/2 IK x 65 65 20 95 95 1.8 - --I- - 1 3.75 3.75 sw 3.8 25 95 95 1.7 - -_ 116 3.75 sw 3.75 sw 4.2 32 -95 95 1.7 - . - - 1 ½ 3.75 3.75 3.9 40 95 95 1.8 -------.-- 2 3.75 3.75 sw . 4.5 50 95 -- .- -I--- - 2.0 - - 3 3 x x 3/4 4.25 sw 4.25 sw 5.7 80 80 20 108 108 I 2.6 - - -- .. - - 1 4.25 ' 4.25 6.1 25 108 108 2.8 1 ¼ 4.25 sw 4.25 sw 1 8.0 32 108 108 1 3.6 4.25 4.255W I 6.5 1 ½ 40 108 ' 108 1 2.9 - - - 50 108 I 108 I - - 2.8 - -+- I- -- - 2½ 4.25 4.25sw I 6.4 65 108 5.00 sw 108 ---. 5.00 SW . ------- 29. 8.0 4 4 3/4 100 x x 100 20 127 127 3.6 1 5.00 5.00 7.8 25 127 1 127 3.5 T______ 1 an I gg 11 4 4 x 1 V4 5,005w 5.00 SW 9.6 100 x 100 32 - 127 127 44 11/2 5.00 5.00 10.2 40 127 127 4.6 - -----. . .•- 2 5.00 5.00 11.2 50 127 127 5.1 ------- -- 2½ 5.00 5.00 11.4 65 127 4-.---- 127 .--- 5.2 - - 3 5.00 5.00 11.6 80 127 5.50sw 127 5.50sw 1 5.3 14.0 5 5 1 125 125 x 25 140 140 6.4 1½ 5.505w 5.50sw 14.3 40 140 140 6.5 -9-------.-.- + 2 5.505w 5.50sw 14.5 50 140 140 6.6 - 21/2 5.50 5.50sw 15.2 65 140 140 6.9 3 5.50 5.50sw 16.6 80 140 - --- - - 140 ----------- 7.5 4 5.50 5.50sw 16.7 100 140 6.50 sw 140 6.505w 7.6 23.0 6 6 1 x 150 >< 150 25 165 165 10.4 _--+.- --. .+ -------- 1½ 6.50 sw 6.50 sw 24.0 40 165 165 10.9 2 6.50 6.50 21.6 50 165 165 9.8 - -- -4- ..------t- 21/2 6.50 6.50 21.4 65 165 165 11.7 14-60 I A05 For AGS fitting information, see publication 20.05 350-1500mm + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP' clearly on order. www.victaulic.com viclAuLic IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. C 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_b 4tauiicr REVR CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee bCto .-CtoE.1 4CtoE1 .-CtoE.1 NO. 25 Grooved Branch NO. 29T Threaded Branch l C C C C to to to to NO. 25 NO. 29T NO. 25-Sw NO. 29T-SW N58itT CluE rheIU Nl rS Size .!nchesInclI l8hes 6 6 3 6.50 6.50 26.5 12 12 1 10.00sw 10.00 Sw 77.0 150 150 X so 165 165 12.0 300 X 300 X 25 254 254 34.9 - --.- + 4 6.50 6.50 25.0 2 10,005w 10.00 Sw 80.0 100 165 . 165 - 11.3 50 254 254 3 36. 5 6.50 6.50 23.2 2½ 10.00sw 10.00sw 78.0 125 165 6.50 165 6.505w 10.5 24.0 65 254 254 35.4 ---.,----- - .- --- 3 10.00sw 10.00sw 82.0 61/2 61/2 3 165.1 165.1 80 165 165 ± 10.9 80 254 37.2 _254 4 6.50 6.50sw 25.0 .--- ---,-.-.---- ----- 4 1000sw 10.00sw 80.0 100 7.75sw 165 165 7.755w 11.3 33.0 100 254 254 36.3 ---- 5 10.00sw 10.00sw 75.0 8 8 1½ x 200 200 40 197 - 197 15.0 125 254 ' 254 34.0 ---.. 2 7.755w ' 7.75sw 33.5 6 10.00sw 10.00sw 75.0 50 197 - --- -- 197 -+-----------.-----+. - 15.2 - - - - 150 254 254 34.0 . ,--..- ,- . + 21/2 775 s 7.75sw 39.0 8 10.005w 10.005w 80.0 65 197 -- _197 - 17.7 200 254 254 - - - ~ 3 7,75sw 7.75sw 33.6 - 10 10.00sw 10.005w 84.0 80 197 197 15.2 250 254 254 38.1 4 7.75 7.75 41.8 #14 x 14 4 11.00sw , 11.00sw 102.0 100 197 - -- 197 --+.---- ±- - 19.0 . --. >< 350 350 100 279 279 46.3 -----+--- ---.-. 5 7.75sw 7.75sw 34.0 6 11.00sw 11.00 Sw 108.2 125 197 197 15.4 150 279 279 49.1 --------.- 6 7.75 7,75 42.3 8 11.00 11.00 112.0 150 197 197 I -'- 19.2 ---. 200 279 279 50.8 -.------ - +.- -- - 65 775 s 7.75sw 48.0 10 11.00 11.00 120.0 197 9.00 197 9.00 21.8 62.0 300 279 . 279 54.4 - - 12 11.00 11.00 129.1 10 10 1½ X 250 X 250 40 229 229 28.1 300 279 ' 279 58.6 -..----..-- 2 9.005w 9.00sw 62.0 #16 16 4 130.0 50 229 229 28.1 400 __400 X 100 _+ ,+59.0 229 229 - 2 83 AGSFor AGS fitting information, see publication 265 0.05 350 - 1500 mm 0-0- 3 9.00 Sw 9.00sw 60.0 + Contact Victaulic for details. 80 229 1 229 272 Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s" 4 -. 9.00 Sw 900sw 100 229 229 27.7 S= Carbon Steel Direct Roll Groove (OGS) ----- - 5 9.005w 9.00 SW 52.0 SW= Carbon Steel Segmentally Welded 125 229 229 23.6 -- - -- : IMPORTANT NOTE: 6 9.00 Sw 9.00 Sw 59.0 150 229 229 26.8 No. 29T Threaded Outlet Reducing Tees are supplied NFl and are available 8 - - 9.00sw - •9.00 Sw . ' 64.7 with British Standard threads. For British Standard specify "BSP" clearly 200 229 _229 29.3 on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. www.victaulic.com ictaulid vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. X/C REVR 07.01_11 CARBON STEEL PIPE GROOVED FITTINGS Grooved End Fittings Reducing Tee NO. 25 Grooved Branch NO. 29T Threaded Branch wm Lt #16 16 x 6 12.00sw 12.00sw 133.5 400 400 150 305 305 60.6 -- 8 12.00 12.00 145.0 200 305 1 305 65.8 -- 10 12.00 1 12.00 149.5 250 305 305 67.8 --4-.-.--- 12 12.00 ------±- 12.00 154.0 300 305 305 69.9 - - ---- - 14 12.00sw . 167.0 350 305 - 75.8 I -4------ #18 18 4 15,50sw 15.50sw . 194.0 450 >< 450 100 394 394 ---'v -- 88.0 ..... - 6 15.50sw I 15,50sw 200.0 150 394 394 90.7 8 15.50sw 15.50sw 202.0 200 394 394 --- 91.6 - 10 --- 15.50 - 15.50 212.0 250 - 394 - -- 394 - ----- 96.2 - 12 15.50 15.50 222.6 300 394 394 101.0 14 15.50 230.1 350 394 - J9± 16 15.50 247.6 400 394 - 112.3 #20 20 x 6 17.25 17.25 - 240.0 500 500 - 438 - 438 1089 - 8 17.25 1725 244.0 200 438 438 1107 10 17.25 17.25 -- 256.0 250 438 438 1161 ------ 12 17.25 17.25 264.0 300 438 438 1198 14 17,25 275.0 350 438 - 124.7 WIN j.CtoE.j .-CtoE-.1 --- to to NO. 25 NO. 29T T______ 11 an-1 = 11 1 #20 20 x 16 17,25 288.6 500 500 400 438 - 130.9 18 17.25 297.0 450 438 - 134.7 20.00 20.00 340.0 # 24 24 8 600 600 x 200 508 508 154.2 10 20.00 20.00 343.9 250 508 508 156.0 4- -------_ - - 12 20.00 20.00 . 352.8 300 508 508 160.0 -- 4--.--- 14 § 20.00 360.0 350 508 - 163.3 16 20.00 378.0 400 508 - 171.5 -----4-- -4- 18 § - 20.00 380.0 450 . 508 - 172.4 20 ------ 20.00 373.0 500 508 - 169.2 350-1500mm AGSFor AGS fitting information, see publication 20.05 + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an 'sw" or "s' S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. # For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Cast fitting available. Contact Victaulic for details. www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.0112 ,%tauIicr REV_R INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 08/2012 07.01 1449 REV R actaulic VICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAuLIc COMPANY. ALL RIGHTS RESERVED. 07.01 FireLock EZ® Rigid STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe 1¼ 175 365 365 365 365 . 1206 2517 _.2_ -- •JL..., 1½ . 175 365 365 365 365 40_412O6 2517 425172517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 2½ 1 N A 365 365 365 365 2517 2517 _2517_ 2517 76.1 mm N/A N/A 365 365 251 365 2517 2517 N/A 365 365 , 365~ 365 —0.----+—. 2i2517~ 2517 - 2517 108 mm N/A 2517 2517* N/A N/A 365365 365 - •' - - 100 ,• 2517 2517 2517~ 2517 - 290m 365m 133 mm N/A 1999w 2517k" N/A N/A -- 290 139] mm N/A N/A 1999 1600 2517 165.1 mm N/A N/A 290 232 365 -- •----- 68 290 365 1 232 365 N/A ' 1508 1999 2517 1600 2517 * Listed/Approved for wet and dry pipe systems (>-40F1-40°C). Please refer to the Victaulic Installation Manual (1-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) Regional availability only# FM Approved only. JOB/OWNER CONTRACTOR ENGINEER System No, Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REVG \4taulicr 10.61_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H LISTINGS/APPROVALS * Speciality Pipe BLT - 300 11/4 - 2 2068 300 2068 DF 300 1¼-4 2068 2068 300 300 1¼-2 2068 2068 - 175 175 14-4 1206 1206 -_- ----4- - DT - EF EL - 1 1/4-2 2068 - - 1¼-2 60 2068 -- 300 2068 300 2068 300 300 2068 ET40 - EZF I 300 300 MT 1 1A2 300 300 Ef 122068 2068 300 101 1¼-2 N/A 20682068 300 FF MLT i¼48 2068 - 2068 j00 300 FLF 1¼-4 N/A 2068 ST 11/4-2 N/A 2068 — 300 — — - + FLT 1 ¼ - 2 N/A STF 1-4 - 4 N/A 300 2068 - -4------- -4- 1¼-2 N/A 3 2¼-4 - —i- --+- 2068 FLTL N/A 300 — 2068 --.—— — 2068 GL 300 3 1 - 2 300 0 1 /4 - 2 2068 20681i¼-2N/A6 300 300 2068 20 1¼-4 300 2068 2068 175 MF 1¼-2 XL Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric sizes. www.victaulic.com \14tauIic vicTAuLic IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 10.612 REVG IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 0.6 1 FireLock EZ® Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS l ' I (4.Z- . II I tta 1 0 11 1_• _it_a1l . F i1i r GMA ILJ_I x 1¼ 1660 365 790 010 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.4 32 42.4 2517 3514 2.54 - M1O x 2 75 121 69 118 49 0.7 + -1-- -. ------ -f -4- -4-- --4-- '4- 1½ 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 - - Mb x 2 81 126 75 122 -_ _ 49 0.7 -4---- -+--_I - -- 1-- --•- -.. - -- -4---- STYLE 009H PRE-ASSEMBLED 2 2.37 5 365 1616 0.12 2 - 3/8 x 2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 1 2517 7193 3.05 - Mb x 2 96 140 88 138 49 0.9 -4- 2½ 2.875 365 2370 012 2 - 3/8 x 2½ 4.29 6.09 3.92 5.85 193 2.1 V l*Z-( 65 73.0 2517 10542 3.05 -M10x21/2 1 109 155 100 149 49 1.0 -4- - 4-_ -+---------4-- -i- - ._4- -. - .....- - 3.000 365 2580 0.12 2 - 3/8 x 2 1/2 I 440 6.31 4.05 5.90 1.93 2.1 76.1 mm 76.1 2517 11476 3.05 -MID x2½ 112 160 103 150 49 1.0 4. '-'-. .....__- - x 3 3.500 365 3512 0.12 2 - 3/8 x 2½ 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 -M10x2½ 125 170 116 164 49 1.0 - - - I I -4---------- ------4-- ........- 108 rn 4.250 365 5178 0.17 2 -3/8x2 ½5.56 7.61 5.27 7.51 2.14 2.8 MM 108.0 2517 23030 4.32 I - MIO x 2½ 141 193 134 191 54 1.2 STYLE 009H JOINT ASSEMBLED 4 4.500 365 5805 0.17 2 - 3/8 x 2½ 595 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 - MID 2½ 151 199 141 190 55 1.3 -- I I -- *----4- - - 4- - - : --- - 133 mm 5.250 365 7900 0.17 2 -3/8x2 ½ 6.66 9.11 6.36 9.01 2.14 4.3 133.0 2517 35140 4.33 -M10x21/2 169 232 162 229 55 1.9 ---+------- --+ ----- ---4- - - - - + -+- 5.500 365 8620 017 , 2 - 3/8 x 2 ½ 6.75 9.29 6.46 9.23 2.09 4.6 139.7 mm 139.7 2517 383404.32 - M10 x 2½ 172 236 164 234 53 . 2.1 I_+ 4_-4.-_ --- _ _.4-. - -_.__ 1651 mm 6.500 290 9623 0.17 2 -5/8x3 1/4 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 -M16x3¼ 199 278 192 276 54 2.6 + . - 4-._._ -4___ i - __4_._ __f - - ._ . - -- 6 6.625 290 9997 0.17 . 2 -5/8x 3 ¼ 7.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 - M16 x 31/4 202 281 195 305 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown in the chart on page 1, specific to pipe schedule and size. The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America, Asia Pacific) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAuLIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY, © 2012 vIcTAuLIc COMPANY ALL RIGHTS RESERVED. \4taulic REV,G 10.613 STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 0091-1 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps con- taining the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade E" Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV G UPDATED 09/2012 iCtaUliC' viciuic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 10.61 Victaulic® Flexible Coupling Style 75 7'1 Exaggerated for clarity Approvals/Listings Zc[LPCB]® € See Victaulic publication 10.01, for details See Victaulic publication 02.06 for portable water approvals if applicable. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or 'T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. 1h__ tau iic 06.05 A WARNING 1 Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 updated 09/2014 4 2014 Victaulic company. All rights reserved. 1 ict9uliC• victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel. 171 Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available, contact Victaulic for details. Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73"FI+23"C and hot +180"F/+82"C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range 20"F to +180"F/29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150"F/+66"C or for hot dry air over +140"F/+60"C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 ___________ 3 4tauIici 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 4,a li Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation3 Centerline Bolt/Nut' X V Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/rn (No.) size inches mm mm mm kg 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2 - 43' 48 2-3/8x2 61 108 45 0.6 1 1/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 - 10' 38 2-3/8 x2 68 117 45 0.6 1 1/2 1.900 500 1420 0-0.06 0.40 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 1 -56' 33 2-3/ x2 74 122 45 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 - 31' 26 2-3/sx2 87 133 48 0.8 21/2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 - 15' 22 2-3/sx2 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 - 1 12' 0.26 2-3/sx2 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 0.22 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 1 -2' 18 2-Y2X2~ 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0-54' 16 2-½x23/4 127 191 48 1.3 4 4.500 500 7950 0-0.13 0.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1 - 36' 28 2-'/2x2~ 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0.13 - 1 41' 0.35 2-12x70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1 -26' 21 2-5/8 x31/4 156 240 54 2.5 5 5.563 450 10935 0-0.13 0.27 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 1 - 18' 23 2-%x31/4 175 256 54 2.6 133.0 mm 5.250 450 9735 0-0.13 1 - 21' 0.28 2-16x82.5 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm 5.500 450 10665 0-0.13 1 -18' 0.28 2-'/8x3¼ 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12735 0-0.13 1 -12' 0.21 2-5/8 x3¼ 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 1 - 5' 18 2-'/8x3¼ 203 281 54 3.2 159.0 mm 6.250 450 13800 0-0.13 - 1 9' 0.24 2-16x82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 8 8.625 450 26280 0-0.13 0-50' 0.18 2-~X4'/4 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 3 1h"/20 -90 mm; 25% for 4/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Reference should always be made to the 1100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our webuite at www.victaolic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaalice is registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 Q 2014 Victaulic Company. All rights reserved. victaulic.com 4 \tauIiC FireLock® Fittings \JtauIiC 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel El Red enamel in Europe, Middle East, Africa, and India Optional: Hot dipped galvanized Approvals/Listings: c@us @1 LISTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic company. All rights reserved. 1 JtauIicr victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: b C to t Le NO. 001 to Cto 1 to W-f b NO. 003 NO. 002 No. 006 No. 001 No. 003 No. 002 No. 006 90 Elbow 45 Elbow Straight Tee Cap Approx. Approx. Approx. Approx. Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm mm mm kg mm kg mm kg mm kg 11/4 1.660 0.82 0.3 32 1 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 761 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 08mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 1 9.7mm 3 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - - 59mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 5. mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. viCtauliC.Com 2 X. Ai_________ Mechanical-I® STYLES 920 AND 920N STYLE 920 CROSS PATENTED STYLES 920 AND 920N Victaulic Mechanical-r Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 forcold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com vIcTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV.M \4tauIic 11.021 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS (2 n. 1 IL 2 /2 (a) 920¼ 500 1.50 2.00 2.53 - 1.61 5.35 2.75 3.1 20 ___ 50 15 3450 38.1 51 . 64 41 136 70 1.5 - - --- I --'---''-"--t + 4- ---f---- '-4- 1(a) 920N 500 1.50 1.85 2.53 1.61 535 2.75 3.0 3/ (a) 920N Soo 1.50 1.97 2.53 1.61 5.35 2.75 3.1 38.150 _64 - - - 41 136 70 1.5 - - -1-- ---- +- - -- --- + --- - - 25 3450 38.1 47 64 - 41 136 70 1.4 - --f- 1¼(a)t 920N 500 - 1.75 2.05 2.75 3.00 1.61 535 3.00 3.5 .3.2 GROOVED OUTLET 32 3450 _44.552 70 - 76 41 136 76 1.71.5 I_I - - - --+ -- -+---- 1 /2 (a) t1 920N 500 1.75 - 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 - 3450 44.55270 79 41 1 136 . 83 1.7 1.5 ____ I_I +I- -4--- - -",---- - +- -- 2½ ½ (a) § 1.50 500 2.21 2.74 - 1.82 5.64 2.75 3.0 - 65 15 3450 38.1 56 I - 70 - 46 143 70 1.4 -4- - I ---- --4------- +------ ± --,---- 4/4 (a) § a 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - I 46 1 143 70 1.4 - 1(a) § - - 5QQ 150 I I ' - - I - - + - 206 - 2.74 1.82 5.64 2.75 2.9 25 920N 3450 38.1 52 70 - 46 143 70 1.4 - -. I_-+---- - '- - -----f-------4--- _I_-±----- 1 V4 j (a) 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 j 58 I 76 83 46 160 76 1.7 1.5 1½ I )a) 920N 500 2.00 2.28 I 3.00 3.25 1.82 626 3.25 3.6 3.3 FEMALE THREADED OUTLET 40 I 3450 50.8 58 76 83 .46 159 83 1.7 1.6 --4----- ½ (a) 300 1.50 2.222J5 2.25 6.46 3.18 3.9 + 76.1 x 15 2065 38.1 56 I 70 - 57 164 81 1.8 - Provides a direct branch connection at 34(a) - - - 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 I 920N I -- -4------- -+- . - - - . any location where a hole can be cut 20 2065 38.1 56 70 - -- --+ 57 164 81 1.8 in the pipe 1(a) 920N 300 ____ ----.---- - - 4--- -4-- -+ ------ + - 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 385 453 57_____ 164 81 1.7 __- -4------ -4- ---4-- A pressure responsive gasket provides i ¼ (a) D 920N 500 1.75 2.30 . 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 _______ 3450 44.5 58 76 84 49 I 160 76 1.6 - 1.5 - -- - +-- 1½ (a) 920N 500 2.00 2.28 3.00 331 1.92 6.29 - 3.25 3.5 3.3 Request Publication 11.03 for 40 3450 50.8 58 f_ 84 49 160 83 1.6 1.5 -+ - -- - 1- -4---- 1 ----I -4- - Mechanical-T cross assemblies 3 1/2 (a) 920N 500 1.50 I 2.52 5 . 2.28 80 6.15 2.75 3.4 3450 38.164 -78 _-58 156 70 1.6 - I _I --- 4-- ---b - - -4----.-- Pressure rated up to 500 psi/3450 kPa 3/4 (a) . 500 1.50 2.49 3.05 2.28 6.15 275 3.4 920N on steel pipe; also available for use 20 3450 38.1I63 478 - 58 156 70 1.6 - I -- - - .4- . -- - " - - -- with HDPE pipe 1(a) 920N 500 1.50 . 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 - 61 78 - 58 156 70 1.6 - -- Sizes from 2 x ½750 x 15 mm 1¼ (a) tu 920N 500 1.75 I 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4/200 x 100 mm 32(b) 345044.5 65 83 490 58 156 76 1.8_ I 1.8 I_I--i------ - 1 ½ (a) 920N 500 2.00 2.78 3.50 3.56 . 2.28 6.15 325 45 3.8 40(b) 3450 50.8 - 71 I 89 - 90 58 156 83 1.9 1.8 2 (a) n 920N --+-----4--------4--- - - ±- - + -----4--- - - 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 - 63.5 70 89 90 58 172 99 2.3 2,1 . _ _- _- _ 3½ X - 920N 500 2.50 3.00 I 3.75 244 5.72 - ---- -- 38 90 345063.5 76 95 62 _171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ONPG.3 Style 920 and Style 920N housings cannot be Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). mated to one another t Available with grooved or female threaded outlet. Specify choice on order. to achieve cross connections. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2012 vICTAuuc COMPANY. ALL RIGHTS RESERVED. 11.02 2 -IIIiI, A-c-ta-ulicr REV..M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS V'8 I pss O1f IDiamo jnchesInche na en TABLE CONTINUED FROM PAGE 2 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 3450 38.1 77 90 - 68 178 70 1.8 - -4-- - -4------ -- . -- - - . - .--- + + 500 1.50 4 3.00 3.56 2.69 7.01 2.75 3.7 - - 3450 38.1 76 90 - 68 178 70 1.8 -t- _---i- -4- .,--.-±- + - ---4-' - 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 3450 38.1 73 90 - 68 178 70 1.8 - - - -4- . .• - -. -4----- -. 920N 500 1.75 3.08 3.78 4,00 2.69 7.01 3.00 4.0 3.6 3450 44.5 78 96 102 68 178 76 1.9 1.8 - - - - 500 2.00 I - - -- -- + - 3 - -+ -, - - 920N 3.28 4.00 4.00 2.69 7.01 3.25 4.2 ; 3.9 . 3450 50.8 83 102 102 68 178 83 2.0 1.9 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 3450 - 63.5 83 I 102 102 68 178 99 2.32.1 92 500 2.75 2.88 4.00 1 4.00 2.69 7.34 4.63 5.8 5.0 3450 _69.9 _73 102 102 68 118 186 .------------'-F--. 2.6 2.3 500 ' 2.75 2.88 4.00 2.69 7.34 4.63 6.4 920 . 3450 ' 69.9 73 - 102 68 186 118 - 2.9 - - -4-- - - -4-- - --.4-- ---.4- -. -4---+ --4- +- --1--- - 920 500 3.50 3.31 4.50 4.12 - 2.69 7.73 5.12 8.4 6.4 3450 889 '84 ' 114 105 68 196 130 3.8 2.9 920N i 500 1.75 3.08 . 3.78 ' 2.63 7.64 3.05 5.0 3450 44.5 78 96 - ' 67 194 78 2.3 - - ---. -------•---+ 500 - - 4- --'--1-- - - -'--- ' '-+ - - ~ 2.00 3.28 4.00 2.63 7.64 3.25 5.0 3450 50.8 -83-4- 102 - 67 19 4 - ' +-83- 2.3 - ' .4- - I' - - ' -. - '4- -- 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 . I 3450 63.5 83 - 102 - 67 194 ' 102 1.9 - - 920 500 , 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 - + - + - - ' -4-- -4- ' -4-- - -. ' ---'-4----- + - ---4--------' - 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 3450 88.9 . 84 114 114 I 67 194 124 3.1 3.0 - - --.4- --- .-- -. i________- +-- + 920 l5002.00:4.034.754.75 3.16 9.70369 7417.6 3450 ' 50.8 102 121 121 80 . 246 94 3.4 - 3.4 500 250 4.00 4.75 4.75 ' 3.16 9.70 4.38 82 8.0 920 _3450 - 63.5102 121 121 80 246 111 3.7 3.6 -I------- - -+-------.- - + -- 4 -4-- 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 I -- .-- 3450 ..- f 69.9 92 I I 121 121 -.-- 80 246 --.-- 118 3.8 . 3.6 4---- - 920 I 500 --- 2,75 ' 3.75 ---- 4.75 3.16 9.70 - 4.63 8.0 3450 69.9 95 ' - 121 80 246 - 118 - 3.6 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 3450 ' 88.9 97 127 118 80 246 135 3.8 4.0 I+------s----- -4-------t---- +- - --3-- - -F---- -- - -4-' 920N 500 2.50 3.75 4.50 I - 3.17 8.00 3.88 8.0 - 3450 63.5 95 .114 -----4- 81 ' --- -. .3- 203 - - --4--. 99 3.6 500 3.50 3.81 - 920 5.00 - 3.00 9.46 5.31 8.0 3450 . 88.9 97 127 - . 76 , 240 . 135 3.6 - TABLE CONTINUED ON PG. 4 HULMLW 4 ½(a)a 100 15 _ 34(a) 20 1(a) a 25 GROOVED OUTLET 1¼ (a) fa 32 (b) 11/2 (a) to 40(b) 2 (a) fa ________ 50 2½ (a) t i 1; 65 76.1 mm 3 (a) t _ FEMALE THREADED OUTLET 80 1 ¼ (a(a 108.0 x 32 1 ½ (a(a Provides a direct branch connection at 40 any location where a hole can be cut 2(a) in the pipe 50 • A pressure responsive gasket provides 76.1 mm the seal 3(a) 80 Request Publication 11.03 for 5 Mechanical-T cross assemblies 125 40 2(a) t Pressure rated up to 500 psi/3450 kPa 50 on steel pipe; also available for use 21h(a)f with HDPE pipe 65 • Sizes from 2 x ½750 x 15mm I 76.1 mm through 8 x 4/200 x 100mm 3(a)t 80 133.0 50 80 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate(. Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another Center of run to end of fitting. to achieve cross connections. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.viCtauluC.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 viciuic COMPANY. ALL RIGHTS RESERVED. REV_M \4taulicr 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS i100 ii ij " a& Q QL I MIA ~l (am TABLE CONTINUED FROM PAGE 3 1 ½ t 920N 500 2.00 3.78 4.50 - 3.30 8.23 3.25 7.0 139.7 >< 40 3450 50.8 96 114 84 209 83 3.2 - 2-t 920N 500 2.50 3.75 1 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 - 84 209 99 4.1 - - +- --- - -4 -+---4-- . 4- - + - - - + $5 6 1',4 (a) 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 ISO X32() 4 44.5 112 I 130 130 96 232 83 2.3 - +- GROOVED OUTLET 1 ½ (a) ta 920N50° 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 . 50.8 112 . 130 130 96 232 83 2.4 2.3 - - .- .. -- -- --- 2(a)t 920N 500 2.50 4.38 I 5.13 5.13 3.79 9.15 388 6.0 ________ 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 - -4- - - -4--- +---+ - I - --- +- 2½ 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 - -- 4--- -4-- -I-------1-- - -t-- - - - ---4---- + --4--- 76.1 mm 920 '00 2.75 4.15 5.21 3.69 ' 10.51 4.63 - 8.4 3450 699 105 ' - 132 94 267 118 . 3.8 3(a)) 920 500 3.50 I 4.31 5.50 , 5.13 3.69 10.51 5.31 9.9 8.4 T 3450 88.9 110 14O4..jp 94 267 135 4.5 3.8 4(a) tn 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET - ___________ - 4-' I - - 4- --I- -± - -I- - 1 ½ (a) 920N 500 2.00 4.41 5.13 ' 3.63 . 9.40 3.25 7.8 159.0 x 40 3450 50.8 112 130 - 92 239 83 3.5 - -- 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 Provides a direct branch connection at so 3450 63.5 111 130 - 92 239 99 3.6 - --4----'--+ ..4- - 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 , any location where a hole can be cut 76.1 mm 920 3450 699 111 140 130 92 239 118 43 43 in the pipe ... . - - + - - .4_ ............ ~ 920 500 . 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 A pressure responsive gasket provides 80 3450 88.9 110 140 , 130 92 239 135 3.7 6.4 the seal 108.0mm 920 j 500 4.50 4.45 , 5.38 3.63 ' 9.40 6.12 10.0 3450 114.3 . 113 - 137 92 239 155 - 4.5 Request Publication 11.03 for 4 -. - I _________-- 4- 920 500 4.50 . 3.81 ' 5.75 3,63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 3450114.3 _96.80 _146 _-,92.239 '1598.2 ,- TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe * Center of run to end of fitting. Sizes from 2 x 1/2750 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services 11 -PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com JtauIic vIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV_M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Styl Size N IiIii!ililil.Ifl. I I I am am = - 165.1 x 25 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 r 7z:11 3450 38.1 99 116 - 96 237 70 3.6 - _____________ TABLE CONTINUED FROM PAGE 4 - - -1- - - + - --t--- -4- - - --4-- - -I- - -I- - - 1 1/4a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - ------4-------'+----'+----- 't'-- - ' - +----+----- 1½ (a) to 920N 500 . 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8112 _130 , 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 . 63.5 111 130 ' 130 -96 237 99 3.9 2.7 - -- ---± -- 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 . 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 -- - 920 --' - --. - - - 3(a) j a 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 1 8.4 i ______ 80 3450 889 110 140 130 92 267 135 4.6 3.8 - -i-------------4---t----- 4-- 4- 4(a) to 920 500 ' 4.50 3.81 5.75 . 5.38 3.63 10.51 6.25 10.5 8.4 i ___ 100 ' 3450 114.3 _97 146 - . . 137 92 267 159 4.8 3.8 .- .....- 8 2(a) t 920 500 , 2.75 1 5.44 6.19 6.25 4.81 12.42 4.50 11.6 , 11.6 200 50 3450 . 69.9 138 157 159 122 316 114 5.3 5.3 - I_ -1---- I_-'4--- - - -4- -I- ' + ' -+ - 2½(a) t 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 °.L 3450 69.9 122 316 114 5.3 ' FEMALE THREADED OUTLET 500 ' 2.75 5.25 6.25 4.81 12.42 4.56 -- - t 116 76.lmmD 920 3450 69.9133 - 159 122 316 116 - 5.3 ---I- -- -1----------#-- - - + --+- •'- -- - 3(a) to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 920 Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 ____ -----4-----4---+----+ --.+------1------ '--±'- - any location where a hole can be cut 4(a) t - 9 t 500- -4-.5-0 4.50- - 4.81 6.75 6.38 4.81 , 12.42 6.25 15.3 12.5 in the pipe 100 320 450 114.3 122 _171 .1621223161596.9 :57 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides t Available with grooved or female threaded outlet. Specify choice on order. the seal * Center of run to end of fitting. Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500 psi/3450 kPa (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services a LPCB approved for fire protection services Sizes from 2 x ½750 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 10 2012 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV_M IiII I.44-c-ta-ulicr 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C,K, Values: AP = Q2 Where: SP = Where: Q = C x C = Flow Coefficient Q = K, AP = Pressure Drop (bar) Q = Flow (GPM) K, Q = Flow (m3/h) AP = Pressure Drop (psi) K, =Flow Coefficient Exaggerated for clarity Equivalent Outlet Size Length of Schedule OUTLETl1rA 40 Carbon 120)t Steel Pipe FT •Values (d:t.I.11ai) LlfI![1 ½ 0.840 11 - 15 21.3 --.-.- ~ 1.050 16 20 - -- -- - - - - 13.7 -- - 1 1.315 -- 21 - 25 33.7 8 - 1.8 1 Y4 1.660 50 48 32 42.7 42.9 41.1 1 ½ . 1.900 ...... .---------- . 53 Ii 40 ._4 5 2 2.375 112 104 50 603 --------.--.-_----- 10/, 89.1 96 -- -- - 2½ I 2.875 119 150 65 73.0 20 1 12 I, 102 128.5 3.000 76.1 mm 16 161 76.1 - - 138.1 3 I 3.500 249 ' 237 80 88.9 14 15/i -.- 2031 21,3 ,---- ------±. 40 4 4.500 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165ini4.2mm. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2012 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 11.026 JtauIicr REV.M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 —+-- 2755 1999 ----- --- 1599 2496 21/2-4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 2.875 - 4.500 73l14.3___.4 All - SF 2065 300 - 2065 300 2065 300 - 1999 290 - 1599 232 - 2496 362 21/2-4 65-100 73.0-114.3 6.625 168.3 6.625 34 - 10 40 + -- 20--65 300 2065 300 ----------+-------- 2065 300 2065 300 2065 250 1724 300 1999 - 290 1999 290 1599 .-. - 232 1599 232 2496 362 2496 362 6 150 6 150 168.3 8.625 21/2 1 10,40 2065 400 2065 I 2065 - 1999 — 1599 145 . 2496 8 200 219.1 - 8.625 34 . 10 2755 300 — 250 -- — 1000 145 — 8 200 219.1 8.625 ...-- 34 --— 3040 2065 300 ---- 1724 300 -- -.---- - 1000 145 +--—,--. - 8 200 219.1 2065 — , 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vlcTAuuc IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M 11.02_7 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 itauIi vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L mitment — Delivered. S'e~ Npa*ng ri1jIt -w I fiC ALL MALLEABLE THREADED FITTINGS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 197- Standard Spec for Cupola Malleable Iron ASTM A 153- Standard Spec for Zinc Coating (Hot Dip) on Iron and Steel ANSI B 16.3- Malleable Iron Threaded Fittings Classes 150 ANSI/ASME BI.20.1- Pipe Threads, General Purpose (Inch) NPT Ductile Iron Threaded Fittings ALL DUCTILE IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 536- Grade 65-45-12 ASME B 16.3- Ductile Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Cast IronThreaded Fittings ALL CAST IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 128- Class B Standard Spec for Cupola Cast Iron ANSI B 16.4- Cast Iron Threaded Fitting Classes 125 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Steel Pipe Nipples 0 ALL STEEL PIPE NIPPLES MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: (Th ASTM A 53- Standard Spec for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamed ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT www.sigmaco.com (ID MgftgbO@ Thmdgd Ffflngn- O Dimensions: ANSI B16.3 CLASS 150 [1 Coating: Black- none; Galvanized- Hot Dip per ASTMAl53 11 Material: Malleable iron per ASTM Al 97 []Threads: Pipe Threads, General Purpose ASME B1.20.1 Description I I lFQflI LsizE Ii ITEM CIME 1LJ)HiiENKN1 ITEi1i BI-Ackii GALV j[ AJ 3 J Malleable Threaded 90 A 3/8" 1M9060303 1M90B0303G 0.95 0.95 0.17 1/2" 1M90B0404 1M90B0404G 1.12 1.12 0.30 3/4 1M90B0505 1M90B0505G 131 131 045 1" 1M90B0606 1M90B0606G 1.50 1.50 0.73 7 1 1/4 1M90B0707 1M90B0707G 135 1.75 0.97 / 1 1/2" 1M90B0808 1M90B0808G 1.94 1.94 1.30 I B 2 1 M90B0909 1 M9080909G 2.25 2.25 2.06 I - U 2 1/2" 1M90B1010 1M90B1010G 2.70 2.70 355 1M90B1111 1M90B1111G 3.08 3.08 5.46 LISTED 4" 1M90B1212 1M90B1212G 3.79 3.79 8.95 Description I I 'I NOM [SJE.[ I HEM CODE II DIMENSIOW] ITEM 1 BLACK ii GLYJ[_AJI . BJ I w1IGliTJ Malleable Threaded 45 3/8" . 1M45B0303 1M45B0303G 0.80 0.80 0.16 A 1/2" 1M45B0404 1M45B0404G 0.88 0.88 0.22 3/4" 1M45B0505 1M45B0505G 0.98 0.98 0.37 1" 1M45B0606 1M45B0606G 1.12 1.12 0.54 1 1/4 1M4580707 1M45130707G 1.29 1.29 0.86 1 1/2" 1M45B0808 1M45B0808G 1.43 1.43 1.13 2 1M45B0909 1M45B0909G 1.68 1.68 1.79 B 2 1/2" 1M45B1010 1M45131010G 1.95 1.95 2.78 1M45B1111 1M45B1111G 2.17 2.17 4.48 I LISTED 4 1M45B1212 1M45B1212G 2.61 2.61 7.40 Description I I I I NOM IL SJI. I I ITEM CODE lI DMENSUJNI ITEM1 L fflACK I F UP 1I A ILB.. i..WEIGFIT Malleable Thretreeded9O 3/8" 1M90S0303 1M90S0303G. 0.80 1.00 0.17 1/2' 1M90S0404 1M90S0404G 0.88 1.13 0.24 3/4 1M90S0505 1M90S0505G 100 1.31 0.41 / 1M90S0606 1M90S0606G 1.23 1.44 0.62 B 1 1/4" 1M90S0707 1M90S0707G1 1.31 1.69 1.09 1 1/2" 1M90S0808 1M90so808G 1.44 1.88 1.44 F I 1M9050909 1M90S0909G 1.69 11 2.25 2.85 -A---] LISTED - Description I I 11 N0M7E1_ 1. SIZE Ji ITEM DDE ITEM BLACK II V.J[WElaRT-1 Malleable Hex Nut 1/2" 1MLN04 1MLN04G 0.12 3/4" 1MLN05 1MLN05G 0.22 /1 1 1MLN06 1MLN06G 038 \ t 1 / 0 1 1/4" 1MLN07 1MLN07G 0.58 1 1/2" 2" 1MLN09 1MLN09G 1.13 LISTED www.sigmaco.com Malleable Threaded Description t 1 [NOM U ITEMcUOEV llDIIVIENS1Wfl ITEM1 Jt BenMalleable Redudng B 1/2" X 3/8" 1M90R0403 1M90R0403G 1.00 1.06 0.22 3/4" X 1/2" 1M90R0504 1M90R0504G 1.19 1.25 0.38 1" X 1/2" 1M90R0604 1M90R0604G 1.25 1.38 0.46 1" X 3/4" 1M90R0605 1M90R0605G 1.38 1.44 0.56 / - 1 1/4" X 1/2" 1M90R0704 1M90R0704G, 1.38 1.56 0.61 / A 1 1/4" X 3/4" 1M90R0705 1M90R0705G 1.44 1.63 0.71 1 114"X 1" 1M90R0706 :1M90R0706G 1.44 1.66 1.15 / 1 1/2" X 1/2" 1M90R0804 1M90R0804G 1.41 1.66 1.15 1 1/2"X3/4" 1M90R0805 1M90R0805G 1.50 1.75 1.08 1 1/2"X 1" 1M90R0806 1M90R0806G 1.63 1.81 1.02 Ui 11/2" X 11/4" 1 M90R0807 1 M90R0807G 1.81 1.88 1.17 LISTED 2" X 1/2" 1M90R0904 1M90R0904G 1.49 1.88 1.30 2 X 3/4 1M90R0905 1M90R0905G 1 M 200 1.30 2"X 1" 1M90R0906 1M90R0906G 1.75 2.00 1.35 2" X 11/4" 1M90R0907 1M90R0907G 1.88 2.13 1.53 2" X 1/2" 1M90R0908 1M90R0908G 2.00 2.13 1.75 Description IV 1 F-NUWr-j 1 ITEM CODE 1lDIflLIJ ITEM LsLZ. MCGWT-771LVJI Malleable Threaded Tee [ --1 F WELGIII 1/4" 1MT020202 1MT020202G 0.81 0.15 TII I 3/8" 1MT030303 1MT030303G 0.94 0.23 A 1/2 1MT040404 1MT040404G 113 041 I 1 3/4" 1MT050505 1M1050505G 1.31 0.60 J_ .........] 1 1 MT060606 1 MT060606G 1.50 0.90 I 11/4" 1MT070707 1MT070707G 1.75 1.31 J 11/2 1 M1080808 1 M1080808G 1.94 1.73 - - - - A - A 2" 1M1090909 1MT090909G 2.25 2.52 21/2 1MT101010 1MT101010G 269 490 3" 1MT111111 1MT111111G 3.06 7.13 LISTED 4" 1MT121212 1MT121212G 3.81 11.32 Description I I L1TEM crimp ItDiMi ITEM 1 YJtJ wiciiii ..kAct_iL Malleable Threaded Cross A--A- 1/2" 1MX04 1MX04G 1 1.12 0.42 T 3/4" 1MX05 1MX05G 1.13 0.69 k'- t\ 1MX06 - 1MX06G 1.50 1.12 - 11/4" 1MX07 1MXO7G 1.75 1.44 - _______ 11/2" 1MX08 1MX08G 1.94 1.98 _______ - 1MX09 1MX09G 2.25 3.30 - U - 2 1/2" 1MX10 1MX10G -. 2.70 5.90 r A 3" 1MX11 1MX11G 3.08 13.50 I LISTED www.sigmaco.com NUM F 1TEILCOflE II ITEM SIZE [BLAcKJ1GALVJLJffi 1/2" IMK04 1MKO4G 0.14 3/4" 1MK05 IMK05G 0.21 1" 1MK06 1MK06G 0.37 1 1/4" 1MK07 1MK07G 0.58 1 1/2" 1MK08 1MK08G :. 0.74 2" 1MK09 IMKO9G 0.94 2 1/2" 1MK10 1MK10G 1.60 3" 1MK11 1MK11G 2.79 4" 1MKI2 1MK12G 3.66 www.sigmaco.com LISTED Description I I Malleable Cap Malleable Threaded Fitt Description 1 1 1 I Malleable Reducing Tee I NOM IL L - it ITEPJ11flUE It UILVIEN I ITEM TAJL AIY_IL_Al .iI][ Ii - C 1/2"X 1/2 X 3/8 1MT040403 1MT040403G 1.06 1.06 1.06 0.30 3/4" X 1/2" X 1/2" 1MT050404 1M1050404G 1.08 1.08 1.09 0.38 3/4"X 1/2"X3/4" 1MT0504051MT050405G 1.11 1.11 1.13 0.46 I 3/4" X 3/4" X 1/2" 1MT050504 1MT050504G 1.19 1.19 1.25 0.47 B I X 1/2 X 1/2 1M1060404 1MT060404G 1.21 1.21 1.30 058 1" X 3/4" X 1/2" 1M1060504 1MT060504G 1.22 1.22 1.32 0.59 1" X 3/4" X 3/4" 1MT0605051MT060505GIf 1.23 1.23 1.33 1.59 1" X 1" X 1/2" 1MT060604 1MT060604G 1.25 1.25 1.38 0.70 I X 1 X 3/4 1MT060605 1M1060605G 1.38 1.38 1.44 0.82 A 11/4" X 1" X 1" 1MT070606 1MT070606G 1.56 1.56 1.69 1.10 1 1/4 X 1 1/4 X 1/2 1MT070704 1MT070704G 1.38 1.38 1.56 0.98 11/4" X 1 1/4" X 3/4" 1M1070705 1MT070705G 1.40 1.40 1.60 0.94 F 1 1/4 X 1 1/4 X I 1MT070706 1MT070706G 1.56 1.56 1.69 1.20 1 1/2" X 1 1/4" X 1" 1M1080706 1MT080706G 1.63 1.63 1.81 1.30 0L 1 1/2 X 11/2 X 1/2 1MT080804 MT080804G 1.44 1.44 1.69 119 1 1/2" X 11/2" X 3/4" 1MT080805 1MT080805G 1.50 1.50 1.75 1.30 LISTED 1 1/2 X 1 1/2 X 1 1MT080806 MT080806G 1.63 1.63 1.81 1.45 1 1/2" X 1 1/2" X 1 1/4" 1MT080807 1MT080807G 1.81 1.81 1.88 1.52 2 X 2 X 1/2 1MT090904 1MT090904G 1.50 1.50 1.88 1.65 2" X 2" X 3/4" 1 MT090905 1 MT090905G 1.63 1.63 2.00 1.87 2 X 2 X I 1MT090906 1M1090906G 1.75 1.75 200 1.76 2" X2" X 1/4" 1MT090907 1MT090907G 1.88 1.88 2.13 2.35 2 X2 X11/2 1MT0909081MT090908G 200 200 219 255 21/2" X2 1/2" X " 1MT101006 1MT101006G 1.88 1.88 2.38 2.85 21/2 X2 1/2 X 1/4 1MT101007 1MT1010076 206 206 244 336 1/2 1MT101008 1MT101008G 2.19 2.19 2.50 3.46 21/2 X21/2 X2 1MT101009 1MT1O1009G 238 238 262 365 X 3' X 1/2" 1MT111104 1MT111104G 1.76 1.76 2.52 4.03 3 X3 X3/4 1M1111105 1MT111105G 188 1 188 163 403 3" X 3" X 1" 1MT111106 IMT111106G 2.00 2.00 2.62 4.13 3 X3 X11/4 1MT1111O7 [1MT1111o7c 219 219 275 450 3" X 3" X 11/2" 1MT111108 1MT111108G 2.31 2.31 2.81 5.18 3 X3 X2 1MT111109 1MT111109G 250 250 288 570 3" X 3" X 1 1/2" 1MT111110 1MT111110G 2.57 2.57 2.89 5.00 4 X4 X11/4 1M1121207 1MT1212076 239 239 326 747 4" X 4" X 1 1/2" 1MT121208 1MT111208G 2.51 2.51 3.32 7.47 4 X4 X2 1M1121209 1MT1212096[ 275 275 344 839 4" X 4" X 2 1/2" 1MT121210 1MT12121OG 2.75 2.75 3.44 7.70 4 X4 X3 1MT121211 1MT121211G1 331 331 363 893 LISTED LISTED Description [ I Malleable Floor Flange B F A LISTED www.sigmaco.com Description I Malleable Reducing Coupling Malleable Threaded Description I Malleable Coupling TEM ITEM UUDE JEDIIIVL I FVw&,tpRT SiZE [Bt.ACKJ[ GALVJ[ AJ 3/8" 1MCP0303 1MCP0303G 1.18 0.13 1/2" 1MCP0404 1MCP0404G 1.31 0.20 3/4" 1MCP0505 1MCP0505G 1.50 0.30 1" 1MCP0606 1MCP0606G 1.69 0.48 1 1/4" 1MCP0707 1MCP0707G 1.93 0.75 1 1/2" 1MCP0808 1MCP0808G 2.13 1.00 2" 1MCP0909 1MCP0909G 2.50 1.45 2 1/2" 1MCP1010 1MCP1010G 2.88 2.40 1MCP1111 1MCP1111G 3.19 3.30 4" 1MCP1212 1MCP1212G 3.69 5.72 NOM SIZE l' ITEM Lc100E ]UJIIVL I ITEM II BLACK JL.A j 1/2" X 3/8" 1MCR0403 1MCR0403G 0.17 0.17 3/4" X 1/2" IMCR0504 1MCR0504G 0.27 0.27 1"X 1/2" 1MCR0604 IMCR0604G 0.39 0.39 lx 3/4" 1MCR0605 1MCR0605G 0.43 0.43 1 1/4" X 1/2" 1MCR0704 1MCR0704G 0.61 0.61 1 1/4" X 3/4" 1MCR0705 1MCR0705G 0.64 0.64 1 1/4" X 1" 1MCR0706 1MCR0706G 0.68 0.68 1 1/2" X 1/2" 1MCR0804 IMCR0804G 0.78 0.78 11/2" X 1MCR0805 1MCRO805G 0.88 0.88 1 1/2" X 1" 1MCRO806 1MCRO806G 0.88 0.88 1 1/2" X 1/4" IMCR0807 :1MCR0807G 0.90 0.90 2" X 1/2" 1MCR0904 1MCR0904G 1.15 1.15 2"X3/4" 1MCR0905 1MCR0905G 1.34 1.34 2" X 1" 1MCR0906 1MCR0906G 1.40 1.40 2" X 1 1/4' . 1MCR0907 1MCR0907G 1.53 1.53 2"X 11/2" 1MCR0908 1MCR0908G 1.55 1.55 2 1/2" X 1 1/4" 1MCR1007 1MCR1007G 2.09 2.09 2 1/2" X 1 1/2" 1MCR1008 1MCR1008G 2.09 2.09 2 1/2"X2" .. IMCRI009 1MCR1009G .. 2.51 2.51 3" X 1 1/4" 1MCR1107 1McR1107G 2.99 2.99 3"X 11/2" 1MCR1108 1MCR1108G 3.30 - 3.30 3"X2" 1MCR1109 1MCRII09G 3.25 - 3.25 3" X 2 1/2" 1MCR1110 . 1MCR111OG 3.29 3.29 4" X 1 1/2" 1MCR1208 1MCR1208G 4.90 4.90 4 X2 1MCRI209 MCR1209G -1 510 510 4"X2 1/2" 1MCR1210 1MCR121OG 6.55 6.55 4" X 3" 1MCR1211 1MCR1211G 4.04 4.04 90111 I ITEM CODE 1EIIIMENSIONIE ITEM I stzJ[ cc'cJL v.JLkJLi11GHIJ 1/2" 1MFF04 1MFF04G 3.50 • 2.50 0.56 3/4" 1MFF05 1.MFF05G 3.50 2.50 0.60 1MFF06 1MFF06G 4.00 3.0 0.84 1 1/4" 1MFF07 1MFF07G 4.00 3.00 0.90 11/2" 1MFF08 1MFF08G 4.50 3.50 1.20 1MFF09 1MFF09G 5.50 4.25 2.03 Malleable Threaded Fitt Description I I TNUWFIL ITEM CODE [ BLACK_][ GALV j ITEM yjJff Malleable Plug [t J[ 3/8" 1MPLG03 1MPLG03G 0.06 1/2" 1MPLG04 1MPLG04G 0.10 3/4" 1MPLGO5 1MPLG05G 0.17 1" 1MPLG06 1MPLG06G 0.28 1 1/4 1MPLG07 :1 1MPLG07G 0.44 1 1/2" 1MPLG08 1MPLG08G 0.62 1 2" 1MPLG09 :1MPLG09G 0.91 Ui. 2 1/2" 1MPLG10 1MPLG1OG 1.05 LISTED " 1MPLG11 1MPLG11G .. 1.70 MPLG12 1MPLG12G 3.00 Ifll11ii:irni,i* TI4LI LE I"7U 1/2 X 1/4 1MBSH0402 1MBSH0402G 0.06 1/2" X 3/8" 1MBSH0403 1MBSH0403G 0.05 3/4" X 1/2" 1MBSH0504 1MBSH0504G 0.11 1" X 1/2" 1MBSH0604 1MBSH0604G 0.21 1"X3/4" 1MBSH06051MBSH0605G 0.17 1 1/4" X 1/2" 1MBSH0704 1MBSH0704G 0.34 1 1/4" X 3/4" 1MBSH0705 1MBSH0705G 0.31 1 1/4" X 1" 1MBSH0706 1MBSH0706G 0.26 UL 11/2" X 1/2" . 1MBSH0804 1MBsH0804G 0.48 LISTED 1 1/2" X 3/4" 1MBSH0805 1MBSH0805G 0.48 1 1/2" X 1" IMBSH0806 1MBSH0806G 0.43 1 1/2" X 1 1/4" IMBSH0807 1MBSH0807G 0.30 2" X 1/2" 1 1MBSH0904 1] 1MBSH0904G 0.65 2" X 3/4" 1MBSH0905 1MBSH0905G 0.83 ?" X 1" 1MBSH0906 1MBSH0906G 1 0.78 2" X 1 1/4" 1MBSH0907 1MBSH0907G 0.73 2" X 1 1/2" 1MBSH0908 ir 1MBSH0908G . 0.60 2 1/2" X 1 1/4" 1MBSH1007 1MBSH1007G 1.30 2 1/2" X 11/2" 1MBSH1008 1MBSH1008G 1.20 2 1/2" X 2" 1MBSH1009 1MBSH1009G 0.90 3" X 1 1/4" 1MBSH1I07 1MBSH1107G 2.50 3" X 1 1/2" 1MBSHI108 1MBSH1108G 2.30 3" X 2" 1MBSH1109 1MBSH1109G 2.00 3"X2 1/2" 1MBSH1110 1MBSH111OG 1.60 4"X1 1/4" IMBSH1207 1MBSH1207G . 3.20 4" X 1 1/2" 1MBSH1208 1MBSH1208G 3.30 4"X2" 1MBSH1209 1MBSH1209G 3.10 4" X 2 1/2" 1MBSH1210 1MBSH121OG 3.80 4"X3" 1MBSH1211 1MBSH1211G 3.00 www.sigmaco.com - Malleable Threaded Fithn Description I I 1FlqUNM LS(-9 I ITEM LUUE 1EDJNL I ITEM Malleable Union 1/4" 1MUN02 1MUN02G 1.81 0.45 A 3/8" 1MUN03 1MUN03G 1.81 0.42 _____ 1/2" 1MUN04 1MUN04G 1.94 0.44 3/4" 1MUN05 1MUN05G 2.06 0.60 1MUN06 IMUN06G 2.44 0.91 1 1/4" 1MUN07 1MUN07G 2.63 1.45 1 1/2" 1MUN08 1MUN08G 2.75 1.69 1MUN09 1MUN09G 2.94 2.46 1 3" 1MUN11 1MUN11G 3.63 4.95 LISTED 4" 1MUN12 1MUN12G 3.75 8.75 Description I 77777 177 -1 NOPJI . SIZE .I F 1IE1DflE IlDIM. I ITEM BLACK J[ LV_jE ..i I WEIGHI. Malleable Union w/ Brass Seat 1/4" 1MUNBS02 1MUNBS02G 1.81 0.45 A 3/8" 1MUNBS03 1MUNBS03G 1.81 0.42 1/2" 1MUNBS04 1MUNBS04G 1.94 0.44 3/4" 1MUNBS05 1MUNBS05G 2.06 0.60 1MUNBS06 1MUNBS06G 2.44 0.91 1 1/4" IMUNBS07 IMUNBS07G 2.63 1.45 11/2" 1MUNBS08 1MUNBSO8G 2.75 1.69 UL 1MUNBS09 1MUNBS09G 2.94 2.46 " 1MUNBS11 1MUNBS11G 3.63 4.95 - L LISTED . 1MUNBS12 1MUNBS12G 3.75 8.75 Description Malleable Extension 1/2" 1MEX04 1MEX04G 1.95 7.32 r1m LISTED www.sigmaco.com EM- LOudjW DMn nmdW ftbirixi nz:, O Notice: D.I. Fittings have higher tensile strength then fl D.I. Threaded fittings are UL, cUL listed and Factory Mutual that of steel pipe, over tightening can cause damage approved for 500p5i servce. D.I. Per ASTM A 536 grade 65-45- to pipe threads which may cause leakage. D.I. Fitting 12. Dimensions conform to ANSI 1316.3 Class 150. Threads are should be tightened three turns beyound hand tighten, NPT per ANSI/ASME B1.20.1 no more than four turns. Description I I D. 1. 90 Degreed Elbow I IS 100 !JOM SIZE1IiTE1LLHMNSIONJ1 ITEM 1 [ 1090B0606 1.50 1.50 0.62 1 1/4" 109080707 1.75 1.75 0.90 1 1/2" V 1D9080808 1.94 1.94 1.20 1D90B0909 2.25 2.25 1.85 Description I 1 D. 1. Straight Tee L A A fli Lfl c®us UST ED _ UI_ IITM GOOLUIME I ITEM I NOM SIZE-1 cc.iF-7-71F-W-7 n vEi±ui 1DT060606 1.50 1.50 0.85 11/4" 10T070707 1.75 1.75 1.22 1 1/2 1DT080808 1.94 1.94 1.55 1DT090909 2.25 2.25 2.45 Description L 1 D. 1. Coupling I I NOM SIZE R M GoE1Lfl1MJ1 ITEM 1 1DCP0606 1.50 V V 0.85 11/4" 1DCP0707 1.75 1.22 11/2" 1DCP0808 1.94 1.55 1DCP0909 2.25 2.45 Description I D.I.Red.90 Deg. Elbowl - 1 LISTED NOM SIZE WEMCOUE1[DIMEN1UN11 ITEM LcVVJL ViI_UEIGli 1 X1/2" V 1D90R0604 1.26 1.36 V 0.44 I X 3/4" 1D90R0605 137 1.45 0.52 1 1/4 X 1/2 - 1D90R0704 1.34 1.53 0.64 1 1/4 X 3/4" 1D90R0705 145 1.62 0.72 11/4" X " 1D90R0706 1.58 1.67 V 0.75 1 1/2" X " 1D90R0806 1.65 1.80 0.92 11/2" X 11/4" 1090R0807 182 F 1.88 1.08 2" X 1/2" 1D90R0904 149 1.88 1.08 2" X 3/4" . 1D90R0905 V 1.60 1.97 1.24 2" X 1" V 1D90R0906 1.73 2.02 1.40 2" Xl 1/4" V 1D90R0907 1.90 210 1.52 2" X 1 1/2" 1090R0908 2.02 2.16 1.65 Description I D.I. Reducing Coupling F V 'HIA _ IIThMCIFflIflIL II ITEIVI I NOM SIZE [BLACK j[ A JI&ELQHii c®US LISTED 1 X 1/2" - :. 1DCRO604 1.69 V 0.39 1 X 3/4" 1DCR0605 169 0.53 Description I D.I. 45 Degreed Elbow V V I US _ iLISTED NOM SIZE 1MM ITEM L V 1D45B0606 V 1.12 1.12 0.46 1 1/4" 1D45130707 1.29 1.29 0.73 V 1 1/2" 1D45B0808 V 1.43 1.43 0.92 1D45B0909 1.68 1.68 1.50 www.sigmaco.com L1 HTEMCODE]IIDIMFNSONJI jpitv roM SIZ1 3CK WTJ 1 X112 1DBUS0604 075 025 1.42 OUT 0.22 1 X 3/4" 1DBUSO605 0.75 0.25 1.42 OUT 0.17 1 1/4 X 1 1DBUS0706 080028 1.76 OUT 1.28 1 1/2" X 1" 1DBUS0806 0.83 0.31 2.00 OUT 0.44 11/2" XI 1/4 IDBUS0807 083 031 200 OUT 0.30 2"X 1" 1DBUS0906 0.88 0.41 1.95 IN 0.66 2 Xl 1/4 1DBUS0907 0.88 ,0.34 248 OUT 0.72 2" X 1 1/2" 1DBUS0908 0.88 0.34 2.48 OUT 0.61 Description [ 1 D. 1. Cross I I CNZYUS _ D O ! ~ om SIZ'TEMCOE OtMENS1JN1I ITEM - i[aLAcIIL.JL. JEKH. 1 1 DX0606 1.50 1.50 0.98 1 1/4" 1DX0707 1.75 1.75 1.50 11/2 1 DX0808 1.94 1.94 1.90 2" 1DX0909 2.25 2.25 295 1 1/4 X 1 1DX0706 1.58 1.67 1.27 1 1/2" X 1" 1DX0806 1.65 1.80 1.45 2 X 1 1DX0906 1.73 2.02 2.10 Ductile Iron Threaded Fi Description I D.I. Bushing I 1 _ B F C 1.. M_ OUTSIDE HEAD INSIDE HEAD Description L 1 D.I. Cap l r Um 1 t1TM CUDEJ I fliM.. I 1TM 0 NOM SIZE 10K06 1.16 0.32 00 1 1/4" IDK07 1.28 0.43 1 1/2 1DK08 1.33 0.60 1DK09 145 0.91 www.sigmaco.com Description I 1 D. 1. Reducing Teel I L Ism B 13 NOM szI IllIEMICODElE NMENSION I [[EM 1EJr][-A--J1 B 1 x 1 x 1/2 10T060604 1.26 1.26 1.36 0.64 1" x lx 3/4" - 101060605 1.37 1.37 1.45 0.73 - 1"x1/21,x1" 1D1060406 1.50 1.36 1.50 0.71 1" x 3/4" xl" 1D1060506 1.50 1.45 1.50 0.76 1 x 1 11 x 1 1/4 1DT060607 1.67 1.67 1.58 098 l"xl"xl 1/2" 1DT060608 1.80 1.80 1.65 - 1.16 1 1/4" xi" x 1/2" 1DT070604 1.34 1.26 1.53 0.82 1 1/4"x1"x3/4" 1DT070605 1.45 1.37 1.62 0.90 11/4' x 1"x 1" 1DT070606 1.58 1.50 1.67 1.00 11/4" x 1" x 11/4" 1DT070607 1.75 1.67 1.75 1.08 1 1/4"x 1" x 11/2" 101070608 1.88 1.88 1.82 1.42 11/4" x 11/4" x 1/2" 10T070704 1.34 1.34 1.53 0.86 11/4 x11/4x3/4 1D1070705 145 145 162 092 11/4" x 1/4" x 1" 1D1070706 1.58 1.58 1.67 0.95 1 1/4 x 1 xT 1/4 X'1 1D1070708 1.88 1 M 1.82 1.45 11/4" x 1/4" x 2" 1DT070709 2.10 2.10 1.90 1.75 1 1/2 x 1 x 1/2 1DT080604 1.41 1.34 1.66 0.95 - 1 1/2"x V 3/4" 1D1080605 1.52 1.37 1.75 1.14 1 1/2 x x - 1D1080606 165 150 180 117 11/2" x " x 11/4" 10T080607 1.82 1.67 1.88 1.34 I 1/2"x 1"x 11/2" 101080608 1.94 1.80 1.94 1.45 1 1/2" x 11/4" x 1/2" 1DT080704 1.41 1.34 1.66 1.05 1 1/2 x 1 1/4 x3/4 1D1080705 1.52 1.45 1.75 115 11/2" x 1/4" x1" 1DT080706 1.65 1.58 1.80 1.25 11/2 xl 1/4 x2 10T080709 216 210 202 190 11/2" x 11/2" x 1/2" 1DT080804 1.41 1.41 1.16 1.15 1 1/2"x 11/2" x3/4" 101080805 1.52 1.52 1.75 1.24 11/2" x 11/2" x 1" 1DT080806 1.65 1.65 1.80 1.30 11/2 x 1/2 x 1D1080807 1.82 1.82 1.88 1.48 I 1/2"x 11/2" x2" 1DT080809 2.16 2.16 2.02 1.98 2"x1"x2" 10T090609 2.25 2.02 2.25 2.15 2" x 1 1/4" x 2" 1D1090709 2.25 2.10 2.25 2.30 2"x1 112"x1l2" 1DTO90804 1.49 1.41 1.88 1.50 2" x 11/2" x 3/4" 1 DT090805 1.60 1.52 1.97 1.62 21'x1112"x 1" . 10T090806 1.73 1.65 2.02 1.64 2" x 1/2" x 1/4" 10T090807 1.90 1.82 2.10 1.80 2 x 1 1/2x 1 1/2 lDT090808 202 1.94 2.16 2.00 2" x 1 1/2" x 2" 10T090809 2.25 2.16 2.25 2.35 2 x 2 x 1/2 101090904 1.49 1.49 1.88 1.60 2" x 2" x 3/4" - 10T090905 1.60 1.60 1.97 1.68 2"x2"x1..lDT090906 • 1.73 1.73 2.02 1.85 2" x 2" x 11/4" 1D1090907 1.90 1.90 2.10 2.04 2" x2" xl 1/2" lDT090908 2.02 2.02 ' 2.16 2.18 2" x 2" x 2 1/2" 1D1090910 2.60 2.60 - 2.39 3.61 2 1 /T x 2 x 3/4 lDTl 00905 1.74 1.60 232 2.28 COW Mn'rhmdad Ffflngo§ O Cl. Threaded fittings are UL, cUL listed and Factory Mutual approved for 300psi servce. Gray iron per ASTM 126 class B. Dimensions conform to ANSI B 16.4 Class 125 except plugs conform toASME B 16,14. Threads are NPT perANSI/ASME 131.20.1. Description L- C. 1. 90 Degreed Elbow L_ PTM I 1TEF1 NOM SIZE c!cJLJLLJvoHT1 I 1C9080606 1.50 1.50 0.85 11/4" 1C9080707 1.75 1.75 1.22 1 1/2 1C9080808 1.94 1.94 1.55 2" 1C90B0909 2.25 2.25 2.45 2 1/2" 1C90B1010 2.70 2.70 4.80 Description I I C. 1. Straight Tee I A A _ U! 1IITM GUDEII DIMENSION I ITEM LN9M. SIZE BLACK] 1 1CT060606 1.50 11 1.50 0.85 11/4" 1CT070707 1.75 1.75 1.22 11/2 1CT080808 194 '1 194 155 2" 1CT090909 2.25 2.25 2.45 2 1/2" 1CT101010 2.70 2.70 6.39 Description I I C. I. Reducing Coupling I . I NOM SIZE IITMCUUEII DIM. I [CK_IL_A] 'EIGH 1 X 1/2" 1CCR0604 1.69 0.62 1 X 3/4" 1CCR0605 1.69 0.69 Description I C I Reducing I 90 Degreed Elbow (fTA(iLLIMB ® M SI EJ IThM GODEILDIMENsTONJI ITEM I L JLJL IElGHjj 1 X112" 1C90R0604 1.26 1 1.36 0.44 I X 3/4" 1C90R0605 1.37 1.45 0.52 1 1/4 X 1/2 1C90R0704 1.34 1.53 0.64 1 1/4 X 3/4..1C90R0705 1.45 1.62 0.72 11/4" X " 1C90R0706 1.58 1.67 0.75 11/2" X 1/2" 1C90R0804 1.60 1.70 1.17 I 1/2"X3/4" 1c90Ro805 1.61 1.72 1.30 1 1/2" x 1" 1C90R0806 1.65 1.80 0.92 1 1/2"X 1 1/4" 1C90R0807 1.82 1.88 1.08 2" X 1/2" 1C90R0904 1.49 1.88 1.08 2"X3/4' 1C90R0905 1.60 1.97 1.24 2" X 1" 1C90R0906 1.73 2.02 1.40 2" X1. 1/4" C0Po907 . 1.90 2.10 .. 1.52 2" X 11/2" 1C90R0908 2.02 2.16 1.65 Description I I C. 1. 45 Degreed Elbow I IITEMCUEII nIMENSIUNII ITEM a71 NOM SIZE_[BLACK IL1[ i' 1C4560606 1.12 1.12 0.46 11/4" 1C45B0707 1.29 1.29 0.73 1 1/2 1C45B0808 1.43 1.43 0.92 1C45B0909 1.68 1.68 1.50 www.sigmaco.com IM 0 ZE Cast Iron Threaded Description L C. 1. Reducing Tee'_- A ___ B USTtD IlTEMiCODElEDIMENSION II ITbM NOM SIZE [?LAcJLI] LiL lx lx 1/2" 1CT060604 1.26 1.26 1.36 0.95 lx lx 3/4" 1CT060605 1.37 1.37 1.45 1.10 1" x 1/2" x1" 1C1060406 1.50 1.36 1.50 1.08 1" x 3/4" x1" 1C1060506 1.50 1.45 1.50 1.18 1" x 1" x 1/4" 1C1060607 1.67 1.67 1.58 1.52 1" x 1" x 11/2" 1C1060608 1.80 : 1.80 1.65 1.73 11/4" xix 1/2' 1C1070604 1.34 1.26 1.53 1.17 11/4" x 1" x 3/4" 1CT070605 1.45 1.37 1.62 1.38 11/4" xl" xl" 1CT070606 1.58 :. 1.50 1.57 1.47 11/4" x 1" x 11/4" 1CT070607 1.75 1.67 1.75 1.80 1 1/4"x lx 11/2" 1C1070608:. 1.88 1.80 1.82 2.05 I 1/4"x 1 1/4"x 1/2" 1C1070704 1.34 1.34 1.53 1.37 1 1/4"x 1 1/4"x3/4" 1C1070705 1.45 145 1.62 1.54 11/4" x 1/4" x1" 1CT070706 1.58 1.58 1.67 1.65 11/4" x 1/4" x 1/2" 1CT070708 1.88 1.88 1.82 2.21 11/4" x 1/4" x2" 1CT070709 2.10 2.10 1.90 2.55 11/2" x 1" x 1/2" 1CT080604 1.41 1.34 1.66 1.41 11/2" x 1" x 3/4" 1CT080605 1.52 1.37 1.75 1.65 11/2" xix I" 1CT080606 :r 1:65 1.50 1.80 1.65 1 1/2" x 1" x 1 1/4" 1CT080607 1.82 1.67 1.88 2.00 1 1/2"x 1"x 11/2" 1C1080608 1.94 1.80 1.94 2.30 11/2" x 11/4" x 1/2" 1C1080704 141 1.34 1.66 1.58 1 1/2"x 1 114"x3/4" 1C1080705 1.52 1.45 1.75 1.72 11/2" x 11/4" x 1" 1CT080706 1.65 1.58 1.80 1.85 1 1/2"x 1 1/4"x1 1/4" 1C1080707 1.82 1.75 1.88 2.22 11/2" x 1/4" x 1/2" 1C1080708 1.94 1.88 1.94 2.45 11/2 x 1/4 x2 1C1080709 216 210 202 280 11/2" x 11/2" x 1/2" 1CT080804 1.41 1.41 1.66 1.76 11/2" x 1/2" x 314" 1c1080805 1.52 1.52 1.75 1.87 11/2" x 11/2" x 1" 1CT080806 1.65 1.65 1.80 1.94 1 1/2 x 11/2 x 1 1/4 1C1080807 1.82 1.82 1.88 2.29 1 1/2" x 1 1/2" x 2" 1CT080809 2.16 2.16 2.02 3.28 2" xl" x 2" lCT090609 : 2.25 2.02 2.25 : 3.40 2" x 1 1/4" x 2" 1CT090709 2.25 2.10 2.25 2.80 2" x 11/2" x 1/2" 1C1090804 1.49 1.41 1.88 2.09 2" x 1 1/2" x 3/4" 1C1090805 1.60 1.52 1.97 2.40 2"x 1 1/2"x 1" 1C1090806 1.73 1.65 2.02 2.54 2" x 11/2" x 11/4" 1C1090807 1.90 1.82 2.10 2.85 2" x 1/2" x 1/2" 1C1090808 1.49 1.41 1.88 2.24 - 2" x 1 1/2" x 2" 1CT090809 2.25 2.16 2.25 3.75 2" x2"x1/2" 1CT090904 1.49 1.49 1.88 2.60 2" x 2" x 3/4" 1C1090905 1.60 1.60 1.97 2.71 2" x 2" x1" 1CT090906 1.73 1.73 2.02 2.97 2" x 2" x 11/4" 1C1090907 1.90 1.90 2.10 3.32 2" x 2" x 1 1/2" 1CT090908 2.02 2.02 2.16 3.72 2" x 2" x 2 1/2" 1CT090910 2.60 2.60 2.39 5.10 www.sigmaco.com Description I C.I. Plugs I . I 1N OM SIZE IIIThM OUE1I DIM I ITEM I 1/2" .. 1CPLG0404 0.94 0.10 3/4" 1CPLG0505 1.07 0.17 1CPLGO606 1.25 0.28 1 1/4" 1CPLG0707 1.36 0.44 - 11/2" . 1CPLG0808 1.45 0.62 2" 1CPLG0909 1.56 0.91 Description 1 1 C. 1. Cross I. I A A LIoM SIZEIIITEM COD1[DIMENSION1[ ITEM I L _JLaAcK. J A lE. lCX0606 1.50 1.50 1.54 1 1/4" 1CX0707 1.75 1.75 2.40 1 1/2 1CX0808 1.94 1.94 3.10 1CX0909 2.25 2.25 4.00 11/4")( 1" 1. 1CX0706 1.58 1.67 2.05 1 1/2" X 1" 1CX0806 1.65 1.80 2.40 2" X 1" 1CX0906 1.73 2.02 2.75 UL1p©rrft Po"mNoopphm" O Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME B1.20.1 Description L 1111 Black Steel I LENGTH ii" JI 1/4" 1L !8" .11 NOMINAL J" 1t_'4J SIZE 1" .JE_flL4 J[ 1iJ2".JL_ I 2" J CLOSE 1NBO101 1NB0201 1NB0301 1NB0401 1NB0501 1NBO601 1NBO701 1NB0801 1NB0901 11/2" 1NBO108 - 1N80208 1NB0308 1NB0408 1NB0508 NA NA NA NA 2" - 1NBO109 1NB0209 1NB0309 1NB0409 1NB0509 . 1NB0609 1N80709 . 1NB0809 . NA 2 1/2" 1NB0110 1NB02010 1NB0310 1NB0410 1NB0510 1NB0610 1NB0710 1NBO810 1NBO910 3" 1NBO111 1NB0211 1NB0311 1NB0411 1NBO511 1NB0611 140711 1NB0811 1NB0911 3 1/2" 1NB0111-5 1NBO211-5 1NB0311-5 1NB0411-5 , 1NB0511-5 1NB0611-5 1NB0711-5 1NB0811-5 1NB0911-5 V " 1NBO112 1NB0212 1N80312 1NB0412 1NB0512 1NB0612 .. 1NB0712 1NB0812 1N80912 41/2" 1NBO112-5 1NB0212-5 1NB0312-5 1NB0412-5 1NB0512-5 1NB0612-5 1NB0712-5 1NB0812-5 1NB0912-5 V 1NBO113 1NB0213 1NB0313 1NB0413 1N80513 1NB0613 1NB0713 1NB0813 1NB0913 5 1/2" 1NBO113-5 1NB0213-5 1NB0313-5 1NB0413-5 1NB0513-5 1NB0613-5 1NB0713-5 1NB0813-5 1NB0913-5 6" 1NB0114 1NB0214 1NB0314 1NB0414 1NB0514 V 1NB0614 V 1NB0714 V 1NB0814 1N80914 V 61/2" 1NBO114-5 1NB0214-5 1NB0314-5 1NB0414-5 1NB0514-5 1NB0614-5 1N60714-51NB0814-5 1NB0914-5 NA V• NA NA NA V NA 1NB06147 1NB07147 1NB08147 1NB09147 V 7 1/2" NA NA V NA NA NA 1NB0147-5 1NB07147-51NB08147-5 1NB09147-5 V 1NBO115 1NB0215 1NB0315 V 1NB0415 1NB0515 1NB0615 1NB0715 .. 1NB0815 V 1NB0915 V 81/2" NA -. NA •V NA NA NA 1NB0615-5 1NB0715-5 1NB0815-5 1NB0915-5 1NBO116 1NB0216 1NB0316 1NB0416 1NB0516 V 1NB0616 .. 1NB0716 V V 1NB0816 VV 1NB0916 V 91/2" NA NA NA NA NA 1NB0616 -5 1NB0716-5 1NB0816-5 1NB0916-5 V 1NB0117 1NB0217 1NB0317 V V 1NB0417 V 1NB0517 V V 1NB0617 V 1NB0717 V 1NB0817 1NB0917 V 10 1/2" NA NA NA NA NA 1NB0617-5 1NB0717-5 1NB0817-5 1NB0917-5 1NBO118 V• 1NB0218 1NB0318 1NB0418 1NB0518 V 1NB0618 . 1NB0718 V 1NB0818 1NB0918 V 111/2" NA V NA NA V NA NA 1NB06185 1NB0718-5 1NB0818-5 . 1N80918-5 V V 12" V 1NBO119 -. 1NB0219 1NB0319 VV 1NB0419 . 1NB0519 V V 1NB0619 . JNBO719 . 1NB0819 V V 1NB0919 F LILa' SIZELENTT It NOMINAL i". u I V CLOSE 1NB100I 1NB1101 1NB1201 11 1NB1401 - 1NB1011 1NB1111 NA NA 31/2" 1NB1011-5 1NB1111-5 1NB1211-5 NA•V 1NB1012 1NB1112 1NB1212 NA V 41/2" 1NB1012-5 1NB1112-5 1NB1212-5 - NA 1NB1013 1NB1113 1NB1213 NA 51/2" - 1NB10I3-54 1NB1113-5 1NB1213-5 V NA - 1NB1014 1NB1114 1NB1214 1Nf1414 8 1NB1015 1NB1115 1N81215 1NB1415 91, 1NB1016 1NB1116 1NB1216 IN B1416 V 1NB1017 1NB1117 1NB1217 1NB1417 1NB1018 1NB1118 1NB1218 1NB1418 12 1NB1019 1NB1119 1N81219 1NB1419 D D 0 www.sugmaco.com U© Po'm Mjpo(m adwanum []Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME 131 .20.1 Galvanized to spec. ASTM A 153- for zinc coating. Description I Galvanized Steel'______________________________________________________ I NOMINAL ZE LENGTH .i'" IL__"_ JL.318" .11. 1/2".J[ 3/4"7L_ CLOSE 1NG0101 1NG0201 1NG0301 ING0401 ING0501 1NG0601 1NGO7O1 1NG0801 1NG0901 1" - NA 1NG0201-1 NA NA NA NA NA NA NA 11/4 NA NA NA NA NA NA NA NA NA 11/2" 1NG0108 1NG0208 1NG0308 1NG0408 1NG0508 NA NA NA NA 2 1NG0109 1NG0209 1NG0309 1NG0409 1NG0509 1NG0609 1NG0709 1NG0809 NA 2 1/2" 1NG0110 1NG02010 1NG0310 1NG0410 1NG0510 1NG0610 - 1NG0710 1NG0810 1NG0910 3 1NG0111 1NG0211 1NG0311 1NG0411 1NG0511 1NG0611 1NG0711 1NG0811 1NG0911 31/2" 1NG0111-5 1NG0211-5 1NG0311-5 1NG041I-5 1NGO511-5 1NG0611-5 ING071I-5 1NG0811-5 1NG09I1-5 4 1NG0112 1NG0212 1NG0312 1NG0412 1NG0512 1NG0612 1NG0712 1NG0812 1NG0912 4 1/2" 1NG0112-5 1NG0212-5 1NG0312-5 1NG0412-5 1NG0512-5 1NG0612-5 1NG0712-5 1NG0812-5 1NG0912-5 51, 1NG0113 1NG0213 1NG0313 1NG0413 1NG0513 1NG0613 1NG0713 1NG0813 1NG0913 51/2" 1NG0113-5 1NG0213-5 1NG0313-5 1NG0413-5 1NG0513-5 1NG0613-5 1NG0713-5 1NG0813-5 1NG0913-5 6" 1NG0114 1NG0214 1NG0314 1NG0414 1NG0514 1NG0614 1NG0714 1NG0814 1NG0914 6 1/2" 1NG0114-5 1NG0214-5 1NG0314-5 1NG0414-5 1NG0514-5 1NG0614-5 1NG0714-5 1NG0814-5 1NG0914-5 7" NA NA NA 1NG04147 NA 1NG06147 1NG07147 1NG08147 1NG09147 8" 1NG0115 1NG0215 1NG0315 1NG0415 1NG0515 1NG0615 1NG0715 1NG0815 1NG0915 81/2 NA NA NA 1NG04155 NA NA NA NA NA 9" 1NG0116 1NG0216 1NG0316 1NG0416 1NG0516 1NG0616 1NG0716 1NG0816 1NG0916 10 1NG0117 1NG0217 1NG0317 1NG0417 1NG0517J 1NG0617 1NG0717 1NG0817 1NG0917 11 1NG0118 1NG0218 1NG0318 1NG0418 1NG0518 1NG0618 1NG0718 1NG0818 1NG0918 12 1NG0119 1NG0219 1NG0319 1NG0419 1N-G0519 1NG0619 1NG0719 1NG0819 1NG0919 • NOMINAL SIZE I LLENHL2IY, Ji 3 1'JL J CLOSE 1NG1001 • 1NG1101 • 1NG1201 ' 1NG1401 3" 1NG1011 1NG11I1 NA NA • 31/2" 1NG1011-5 1NG1111-5 NA NA . • 4" 1NG1012 1NGI112 1NG1212 NA 4 1/2" 1NG1012-51. 1NG1112-5 1N61212-5 - NA 5" 1NG1013 1NG1113 1NG1213 NA 51/2" 1NG1013-5 1NG1113-5, 1NG1213-5 NA - 6" INGI0I4 1NG1114 1NG1214 1NG1414 NA • 1NG1114-5, NA NA 1NG1015 1NG1115 1NG1215 1NG1415 91, 1NG1016 1NG1116 1NG1216 1NG1416 10" 1NG1017 1NG1117 1NG1217 1NG1417 Il 11" 1NG1018 1NG1118 1NG1218 1NG1418 1 12" 1NG1019 1NG1119 1NG1219 1NG1419 I www.sigmaco.com CON L LI Manufactured from carbon steel (which conforms to ASTM A 865 standard) 0 Threads conform to ASME 131.20.1 standards for pipe threads. O Sizes 2" and below are straight tapped and 2 1/2" and above are tapper tapped. Description I Size Item Code D L 1 1/2" 1 MCC0404 1.063" 1.563" 3/4" 1MCC0505 1.313" 1.625" 1MCC0606 1.576" 2.00" 1-1/4" 1MCC0707 1.900" 2 063" 1-1/2" 1MCC0808 2.200" 2.063" 1MCC0909 2.750" 2.125" 2-1/2" 1 MCC1 010 3.250" 3.125" 1MCC11II 4.00" 3.250" IMCCI212 5.00" 3.500" www.sigmaco.com victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 inches inches mm mm 90° Elbow 45° Elbow Branch Run 11/4 1.660 - - - - 32 42.4 - - - - 1½ 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POF format on our website at www.victaalic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic"' is a registered trademark of Victaulic Company. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic company. All rights reserved, victaulic.com 3 __________ Patent #5,344,108 Approx. Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) Pipe Clamps TOLCO Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2" (40mm) pipe. C®us, Material: - Pre-Galvanized Steel USTED Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Part number and band hanger, size from iolol 3/4" (20mm) thru 2" )40mm(. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 99 B-Line series Pipe Hangers & Supports Component of State of California OSHPD Approved Seismic Restraints System Set Screw and Locknut Included Beam Clam TOLCO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening TOLCOTM Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2".13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - /8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" 115mm) thru 4" (100mm) pipe 1/2'_13 rod will support 1/2" (15mm) thru 8" (200mm) pipe Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-1/2 1/2"13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-/8 /8"-11 1 1/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Mac Rec. Load * Approx. WtJ100 No. in. (mm) lbs. (kN) lbs. (kg) 65_1/2 11/4" (31.7) 1130 (5.02) 55 (24.9) 65-I8 11/4" (31.7) 1130 (5.02) 55 (24.9) * Maximum loads for clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. Fig. 65XT-3/8 - Beam Clamp Feature: Extruded holes allow for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Design Load: 730 Lbs (3.25kN) Finish: Plain or Electro-Ga Ivan ized Order By: Part number and finish Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering Approved (FM) for up to 4" (100mm) pipe. C&S <~> LISTEO (19.O Set Screw and Locknut Included (222) (34.9) Note: See page 27 for recommended setscrew torque. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 33 B-Line series Pipe Hangers & Supports Component of State of C@ Vi.us California OSHPD Approved USTED Seismic Restraints System A-A Beam Cl TOLCO Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: /8'-16 & 1/2'13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Order By: Part number, length, and finish. Note: Minimum return on strap is 1"125.4mm1 * Patent #5,947,424 Slot Width For Use With Length Part No. in. (mm) B3033-3/t, B3O34-/8, B3031-3/8, 69R-3/8-L /16" 111.11 Specify 65-/8, 65X1-3/8, 66-/8 6911-1/2-11. /16" (14.3) B3033-1/2, B3034-1 /2, 65-1/2, 66-1/2 Specify All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 38 Eaton Wit Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions od Max. Rec. Load Lbs. For Service Temp 650°F 3/8 730 1350 5/8 160 3/4 7/8 448 Component of State of California OSHPD Approved Seismic Restraints System •.-, F~g. 98 - Rod Stiffener Fi98B - Rod Stiffener w/Break-off Bolt Head Size Rangbkv 3/8 thru 7/8" hanger rod Material - Ca' Steel Function - Se cure to hanger rod for vertical seismic bracing. Approvals - Seismic Restraints CataloQ approved FIG. 98 Finish - Electro Galvanized Note - Available in HDG finish or Stainless materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 1112" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 - All Thread Rod Full Lennth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com c®Us USTED Set Screw Included Mounting Hardware Is Not Included (I) 981 K All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 182 B-Line by Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - I811-16 to /411-10 rods Component of State of California OSHPD Approved Fig. 980H - Universal Swivel Sway Brace Attachment - I811 -9 to 11/4"_7 rods Seismic Restraints System Size Range: One size fits bracing pipe 1(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO braced pipe attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe. Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note: Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 413 or Fig. 4L pipe clamps make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. US Patent Numbers Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 980-I8 51/4' (133.3) 1I8" (47.6) 13/32" (10.3) 2015 (8.96) 1320 (5.87) 1970 (8.76) 2310 (10.27) 2550 146 (11.34) 149 (67.6) 980 1 /2 51/4" (133.3) 1l8" (47.6) /32" (135) 148 (67.1) 980I8 51/4" .(11 1/8" (47.6) 116" _(17.)_ ..14.7 !ZL 980-/4 51/4" .(1 1/8" (47.6) 13116" _(05) (66.2) 980H 7/8 6I4" )17.:4) 31/2" (88.9) /16" iL _4_. (!!) 980H-1 6I4" (171.4) 31/2" (88.9) 11/16" (27.0) 400 (181.4) 980H-11/8 6I4" (171.4) 31/2" (88.9) 1l16" (30.2) 397 (180.1) 980H-11/4 6/4" (171.4) 31/2" (88.9) 1/16" 1 (33.3) 390 1 (176.9) * Mounting attachment hole size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. c@ as <e> LISTED Set Screv In All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 170 B-Line by TOLCOTM Seismic Braci ng Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 21/2' (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2" (50mm) through 8" (200mm) pipe. Installation Instructions: Fig. 4L is the braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage bracing pipe into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. / 4-Way Riser Brace'' crc I' 4L-2 2' (50) 5/8" (136.5) 21/16" (52.4) 21/16' (52.4) 1/2"..13 2015 (8.96) -- (--) 247 (112.0) 41_2112 21/2" (65) 6/1' (163.5) 21/2' (63.5) 2/4" (69.8) 1/2"..13 2015 (8.96) 3000 (13.34) 253 (114.7) 41-3 (80) (177.8) 2I4" (69.8) 31/16" (77.8) 1/2"..13 2015 (8.96) 1550 (6.89) 268 (121.5) 41-4 (100) 81/2" (215.9) 3I8" (85.7) 311/16" (93.7) 1/2"13 2015 (8.96) 1550 (6.89) 348 (157.8) 41-5 (125) 93/4" (247.6) 3/8" (98.4) 4 /8" (111.1) 1/2"_13 2015 (8.96) 1450 (6.45) 380 (172.3) 41-6 (150) 111/2" (292.1) 5' (127.0) 51/8' (130.2) 1/2"..13 2015 (8.96) 1450 (6.45) 640 (290.3) 41-8 (200) 131/4 (336.5) 5 /8" (142.8) 5/8" (142.9) 1/211..13 2015 (8.96) 1450 (6.45) 728 (330.2) TTT . - 1_I P •'44P 4L-2 (50) 2015 (8.96) -- -- -- -- 4L-2112 21/2 (65) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 4L-3 (80) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 4L-4 (100) 2015(8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-5 (125) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-6 (150) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-8 1 8" (200) 2015 (8.96) 490 (2.18) 680 (3.02) 830 (3.69) 930 * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11/4", 1112' or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. Seismic Bracing TOLCO Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1(25mm) thru 8' (200mm) IPS. * Pipe size used for bracing: 1,(25mm) and 11/4 (32mm) Schedule 40 IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set screws until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, OPA-0300-10. Finish: Plain or E(ectro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System c®Us <e> LISTED Set Screws tSc Included Pipe Max. Horizontal Design Load (IJL) - Lbs. Size For Brace Pipe Size 1" I 11/4" Sch. 7 Sch. 10 Sch. 40 in. (mm) 1"/11/4" 1"/11/4" 1"/11/4" (25) --I-- 1000/1000 1000/1000 11/4" (32) 1000/1000 1000/1000 1000/1000 11/2" (40) 1000/1000 1500/1500 1500/1500 (50) 1000/1000 2015/2015 2015/2015 21/2" (65) 1600/1600 2015/2765 2015/2765 (80) 1600/1600 2015/2765 2015/2765 (100) 1600/1600 2015/2765 2015/2765 6" (150) 1600/1600 2015/2765 2015/2765 8" (200) 1600/1600 2015/2765 2015/2765 Part Number & Approx. Wt./100 Max. Horizontal Design Load (FM) Pipe For Sch. 1, Sch. 10, & Sch. 40 Pipe 1,23 Size 1' (24mm) Brace Pipe 11/4" (32mm) Brace Pipe 300-440 450-590 600-740 150-90° in. (mm) Lbs. (kg) I Lbs. (kg) Lbs. (kN( Lbs. (kN) Lbs. (kN( Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 153.51 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-1'/4 X 1 100.0 (45.3) 1001-11I4 X 1114 114.0 (51,7) 1230 (5.47) 1740 (7.74) 2140(9.52) 2380 (10.58) 11/2" (40) 1001 -11/2 X 100.0 (45.3) 1001_11/2 X 11/4 115.0 (52.1) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/2" (65) 1001_21/2 X 1 138.6 (62.8) 1001_21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130(5.02) 1380 (6.14) 1540 (6.85) (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 0111/4 inch NPS Schedule 40 GB/T 3091 EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 8-Line series Pipe Hangers & Supports qy 'I/A .71Y[.i'1kJ No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. €r a video demonstration a\ wwwitwbuildex.comJ 1/4' 8002957 GST 100 1/4 x 1" 25 125 670 (314"Ply) 1/4' 8003957 - GST 200 V4x 1760(Rr) 25 - 125 3/8' 8007957 GST 10 1/4 x 1' 210 (7116- OSB) 300 25 125 LL 3I8 8008957 GST 2O 1/4x2 1760(F 850 U7525125 3/8" 8068925 GST 20-SS 1/4x2" 1760 (Fir) 850 25 125 #14 Black 3/8' 8009925 GST2S-380 3/8x2-112' 2113 (Fir) 1500 25 -- 125 - Nut Driver - 3/8" 8010957 GST 30 1/4x3" 2060 (Fir) 1500 1475 25 125 Part#8113910 3/8" 8069925 GST3O-SS 1/4 13' 2060 (Fir) 25 125 - 1/2' 8013925 GS12 1/4x2' 1760 (Fir) 25 125 r 1/2 8015925 GST3 1/4x3 2275(F) 25125 #14 SW Red Nut Driver Part # 8114910 a Qn-l 5WaJFAC105EDu 5AV SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Black Driver 8113910 1W #14 SH Orange Nut Driver Part #8273910 25 125 25 125 25 125 lip ZMYS1 Not less than 2" nominal width / (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4"& 5" pipe I 4 1 Minimum 2-1/2" from bottom for Ibranch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams, No pre-drilling required. 7Flo,,Jo Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. ManufacturedIt1 the IL11 CM osite,Truss Coons t It Sn visas ucture or ec—o-mme-nded sta alma pain. e Watch a video demonstration at W.wwwitwbuildexcom) I 1/4" 8019957 - SWG 200 1/4 x 2" 1725 (Fir) 25 125 I [ _80i0667 SWG10 1/4x1 622(Fvi) 300 25 125 3/8" 8021957 SWG 20 1/4s 2° 1725 (Fir) 1050 25 125 -1 L T.Ti_IiTT.3925_ = SWG2OSS 1/4X2 1725 (Fn) 850 25 - 125 I fL 3/8° 8022925 SWG25-380 3/8x2-112" 2249 (Fir) 1500 25 125 #14SWRed L[ 3/8" 8023925 SWG3O 1/4x3" 1884 (Fir) , - - - 25 , 125 Nut Driver Part #8114910 "May require pre-drilling; consult joist manufacturer LN -' • Eliminates distortion of threaded rod. "Accommodates up to 3 W x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. 3/8" 8139957 SH-GST 20 1/4 x 2° 1257 (Fir) 1050 1475 1903 Dim. Lumber 1500 3/8° 8269957 SH-GST/CST 20 5/16 x 1-3/4° 1406 @ 45°off vertical 850 45° Dim. Lumber 903 Dim. Lumber 1/2 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical Dim. Lumber May require pre.dnlling; consult joist manufacturer. 3.3.5.1 Product Description 3.3.5.2 Material Specifications 3.3.5.3 Technical Data 3.3.5.4 Installation Instructions 3.3.5.5 Ordering Information I MechanicaI;.AnchorirgSystems .e -'4 1KWIK •HUS-EZ riKH-EZ 1) CarboniI Screw Anchor1T 3.3.5.1 Product Description Hilti KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide Specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product Features Suitable for cracked and uncracked normal weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size and uses standard ANSI B212.15 - 1994 drill bits. Suitable for reduced edge distances and spacing. 3.3.5.2 Material Specifications Hilti KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8pm. 3.3.5.3 Technical Data The data contained in Tables 1-4 of this section have been evaluated in accordance with AC 193. For more detail, see ICC-ES ESR 3027. Figure 1 - KWIK HUS-EZ I anchor installation details —I dit I— W - da - .,I.-. ( (anch - - - - h h0 " .c,.f - - •-. - dbjt Listinas/ADorovals ICC-ES (International Code Council) ESR-3027 (Cracked & Uncracked Concrete) FM Approved IN <*> APPROVED Independent Code Evaluation IBC®/ IRC® 2009 (AC 193/ ACI 355.2) IBC®/ IRC®2006(AC 193/ACI 355.2) IBC®/ IRC®2003(AC 193/ACI 355.2) 2 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca •I Anchor Fastening Technical Guide 2011 KWIK HUS—EZ I (KH—EZ I) Carbon Steel Screw Anchor 3.3.5 Table 1 - KWlK HUS-EZ I (KH-EZ I) Design Guidelines For KWlK HUS-EZ Ii Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head d4 in. 1/4 or 3/8 Wrench Socket Size w in. 3/8 or 1/2 Nominal Diameter d in. 1/4 Drill Bit Diameter dbt I in. 1/4 Maximum Installation Torque Tim ft-Ibf 18 Maximum Impact Wrench Torque Rating3 Timpam,, ft-lbf 114 137 Minimum Nominal Embedment Depth h m in. 1 5/8 21/2 Minimum Hole Depth hhole in. 2 27/8 Critical Edge Distance' cac5 in. 2.00 2.78 Minimum Spacing at Critical Edge Distance min,caC in. 1.50 Minimum Edge Distance Cmin5 in. 1.50 Minimum Spacing at Minimum Edge Distance s,in in. 3.0 Minimum Concrete Thickness hmjn in. 3.25 4.125 Anchor Category 3 1 Steel Strength in Tension (ACI 318 D.5.2) Tension Resistance of Steel N lb. 6,070 Reduction Factor for Steel Strength - 0.65 Concrete Breakout Strength in Tension (ACI 318 D.5.2) Effective Embedment Depth hef in. 1.18 1.92 Effectiveness Factor - Uncracked Concrete K uncr - 24 Effectiveness Factor - Cracked Concrete Kcr - 17 Modification Factor for cracked and uncracked concrete 11CN - 1 Reduction Factor for Concrete Breakout Strength cb - 0.45 0.65 Pullout Strength in Tension (ACI 318 D.5.3) Characteristic pullout strength, uncracked concrete (2500 psi) N lb 13056 2358 Characteristic pullout strength, cracked concrete Nper lb 6676 1166 Reduction Factor for pullout strength - 0.45 0.65 Characteristic Pullout Strength, Seismic (2500 psi) N lb 5346 1166 Reduction Factor for pullout strength 0,Q - 0.45 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Pullout Resistance, (uncracked concrete) - Lower Flute NpdkUflCr lb 12108 1875 Pullout Resistance, (uncracked concrete) - Upper Flute NpdkuflCr lb 14908 1960 Pullout Resistance, (cracked concrete and seismic loads) - Lower Flute Npdk Cr lb 6208 930 Pullout Resistance, (cracked concrete and seismic loads) - Upper Flute NPdeCk C, lb 7608 9759 1 The data presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. See Figure 2. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, c,in and minimum spacing distance, s,en or may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (f'c/2,500)03 7 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)15 8 The characteristic pullout resistance for concrete compressive strengths greater than 3,000 psi maybe increased by multiplying the value in the table by (f'c/3,000)03 9 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (fc/2,500)05 Hilti, Inc. (US) 1-800-879.8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 3 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 2 - Calculated ACI 318-08 Appendix D Strength Design Capacity for Single anchor in Tension 3,4,5,6,7 Normal Weight Concrete LWCOMD Anchor Internally Nominal 2500 psi' 4000 psi 3000 psi2 Uncracked Cracked Size Threaded Embedment (in.) Head (in.) Depth (in.) Uncracked Cracked Seismic Uncracked Cracked Concrete Concrete Upper Lower Upper Concrete Concrete Concrete Concrete Seismic Lower Flute Flute Flute Flute 1/4 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4x1-5/8 3/8 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1/4x2-1/2 3/8 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1 Values for other strengths can be calculated per (f'c/2500)°3 for 1-5/8' embedment and (f'c/2500)05 for 2-1/2' embedment 2 Values for other strength can be calculated per (fc/3000)03 for 1-5/8 embedment and (f'c/3000)05 for 2-1/2' embedment 3 Based on single anchor with edge and spacing values greater than those given as critical values in Table 1. 4 Based on lower value of concrete breakout or pullout strength 5 These loads are factored resistance loads in accordance with Chapter 9 of ACI 318-08 (42N,.). 6 Interpolation of values for other embedments is not permitted 7 Minimum concrete thickness and edge distance must comply with Table 1. Table 3- KWIK HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Illustrative Purposes""' 4,5,6,7.8,9,10,11 Internal Thread Diameter Nominal Anchor Diameter Embedment Depth, h 0,,, Effective Embedment Depth, hef Allowable Tension Load of Head (in.) (in.) (in.) (mm) (in.) (mm) lb (kN) 1-5/8(41) 1.18 (30) 470 (2.1) 1/40r3/8 1/4 2-1/2(64) 1.92 (49) 1340 (6.0) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.20 + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 f 4,000 psi (27.6 MPa) (normal weight concrete). 7 c 1 = c ~ c0 , see Table 1. 8 h ~ h see Table l. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 0.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) - 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Figure 2- Installation of KWIK HUS-EZ I (KH-EZ I) in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Mm 3/4 Structural Sand - Lightweight concrete or normal [ weight concrete over steel deck (minimum 3,000 psi) .)f o O4- Lç°- = J=L (Oo cj 1?i .cUcv c oL rp C)10 0000 Li c> Uppe Flute r TcQ, cD(- 4 / 1J (Typ.) steel deck Mm. 4-1/2 LAnchor/ I Flute Edge ...........i Lower (Typ.) Flute Min. 1-1/4 Mm. 12', (Typ.) (Ridge) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 4 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 t(Wll( HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 4 - KWIK HUS EZ I (KH-EZ I) Allowable Stress Design Tension Values for Installations in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Internal Thread Diameter of Head (in.) Nominal Anchor Diameter (in.) Embedment Depth (in.) (mm) Effective Embedment Depth (in.) (mm) Allowable Tension Load lb (kN) Upper Flute Lower Flute 1/40r3/8 1/4 1-5/8(41) 1.18(30) 466(2.1) 378(1.7) 2-1/2(64) 1.92 (49) 885 (3.9) 846 (3.7) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.2D + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 F. = 3,000 psi (27.6 MPa) (light weight concrete). 7 c = c c 0, see Table 1. 8 h see Table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) -. 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Table 5 - Kwik HUS-EZ I (KH-EZ) Tested Load Values for FM Approval for Automatic Sprinkler Systems Hanger Rod Size (in.) Screw Length FM Test Load FM Maximum Pipe Diameter (in.) Tension lb (kN)) (in.) 15/8 3/8 1475 (6.6) 4 2_1/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. Table 6 - Kwik HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Installations into Hollow Core Concrete Panels' .2 Hanger Rod Size (in.) Mm. Effective Embedment h f (in.) Allowable Load' Ultimate Load Tension lb (kN) Shear lb (kN)45 Tension lb (kN) Shear lb (kN)4'5 1/4 13/8 455 (2.0) 485 (2.2) 1810(8.1) 1,930 (8.6) 3/8 755 (3.4) 3,025 (13.5) 1 The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm Admissible Anchor Location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a 4:1 factor of safety. 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of ASTM Al 93, Grade B7 (mm. tensile strength 125 ksi) screws used to fasten the shear fixturing. Shear values should consider the screw or threaded rod strength. Figure 3 - Installation of KWIK HUS-EZ I (KH-EZ I) in Hollow Core Concrete 3.3.5.4 Installation Instructions Use the installation instructions that are including with the Kwik HUS-EZ I packaging box. To obtain a digital copy of the Installation Instructions, visit www.us.hilti.com, www.hilti.ca or contact Hilti Technical Support. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 5 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor The data below is developed from testing performed in accordance with ACI 355.2. It is intended for applications designed according to CSA A23.3-04 Update No. 3 (August 2009) Design Of Concrete Structures Annex D and is generally suitable for the conditions described in the introduction of Annex D. Table 7- KWIK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ II Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head in. 1/4 or 3/8 Wrench Socket Size in. 3/8 or 1/2 Nominal Diameter d in. 1/4 Drill Bit Diameter dblt in. 1/4 Maximum Installation Torque ft-lbf (Nm) 18 (24) Maximum Impact Wrench Torque Rating3 Tmpm,, ft-Ibf(Nm) 114 (154) 137 (186) Minimum Nominal Embedment Depth h nom mm 41 64 Concrete material resistance factor oc - 0.65 Steel material resistance factor 1 - 0.85 Ultimate Strength of anchor steel f1 MPa 924 Effective cross-sectional area of anchor A 0 mm2 29.0 Minimum Hole Depth h801e mm 51 1 73 Minimum Spacing at Critical Edge Distance S ncac5 mm 38 Minimum Edge Distance cmn5 mm 38 Minimum Spacing at Minimum Edge Distance s,in 5 mm 76 Minimum Concrete Thickness hmn mm 83 105 Anchor Category 3 1 Steel Strength in Tension (CSA A23.3 D.6.1) Factored Steel Resistance in Tension N, kN 15.9 Reduction Factor for Steel Strength R - 0.70 Concrete Breakout Strength in Tension (CSA A23.3 D.6.2) Effective Embedment Depth h6f mm 30 49 Critical Edge Distance2 c8 5 mm 51 71 Effectiveness Factor - Uncracked Concrete K uncr - 10 Effectiveness Factor - Cracked Concrete Kcr - Modification Factor for cracked and uncracked concrete Lpc,. - 1.4 Reduction Factor for Concrete Breakout Strength R - 0.70 1.00 Pullout Strength in Tension - Non Seismic Applications (CSA A23.3 D.6.3) Factored Pullout Resistance, uncracked concrete (17.23 MPa) Nprncr kN 2.66 6.8 Factored Pullout Resistance, cracked concrete (17.23 MPa) Nprcr kN 1.3 6 347 Concrete Resistance Factor for pullout strength G'Pull - 0.65 Factored Pullout Strength, Seismic (17.23 MPa) Npreg kN 1.16 1 347 Concrete Resistance Factor for pullout strength I oc'seis - 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Lower Flute Nprdkuflcr kN 2.48 549 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Upper Flute Nprd kuflCr kN 3.08 579 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Lower Flute Np,4ec6cr kN 138 2.7 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Upper Flute Nprdkcr kN 1.51, 2.8 1 The data presented in this table is to be used in conjunction with the design criteria of CSA A23.3-04. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 Tinst,max applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, ç and minimum spacing distance, s,, may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 17.23 MPa may be increased by multiplying the value in the table by (f'c/l 7.23)° 7 The characteristic pullout for concrete compressive strengths greater than 1 7.23MPa may be increased by multiplying the value in the table by (fc/1 7.23)° 8 The characteristic pullout resistance for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (f'c/20.68)0 9 The characteristic pullout for concrete compressive strengths greater than 20.68 MPa may be increased by multiplying the value in the table by (f'c/20.68)05 6 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 3.3.5.6 Ordering Information Order Information Internal Thread Internal Thread Hole Minimum Oty Description Diameter Length Diameter Embedment (pcs) / Box KH-EZ 1/4'xl-5/8" 11/4" 1/4 3/8 1/4" 1-5/8" 100 KH-EZ 1/4"x2-1/2" 1 1/4" 1/4 3/8" 1/4 2-1/2 100 KH-EZ 1/4'xl-5/8" 13/8" 3/8 7/16" 1/4" 1-5/8" 100 KH-EZ 1/4"x2-1/2" 13/8" 3/8" 7/16 1/4 2-1/2" 100 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 7 Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion, and spacing and edge distance guidelines, please refer to the Technical Guide, or contact Hilti. Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com rmo:hPOTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150rmn), 8" (200mm) and 10' (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells -4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- 1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8 (200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6 (150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* 1 .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. !i!ATki;1II[e In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX- 1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 1 OF 2 O1/13 5 3/4" (146) 15/8" (4!) 4 1/4" (108) DWG# 776.2 we fic-Dhp ourn BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 WHITE (IN) WHITE (OUT) - 10" ___ C .LACK __ A.C. BELLS (20 PANEL OR (OUT) 8' FROM CONTROL (150) PRECEDING BELLBLACK (IN) ______ CAUTION: 2 11/16" - WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. H (6 8) DWG# 776-I NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG# 776-3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2' conduit entrance A WARNING Failure to install striker down will prevent bell from operating. PRINTED EN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 VSG POT T LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending, Potter Electric, Rd., 1990 General Information The Model VSG is a flexible vane type of waterfiow switch for use in wet pipe water mist systems where a low flow for alarm is required. It is designed for installation in sections of 2 to 4 inch (50mm to 100mm) stainless steel or brass pipe with wall thickness in accordance with the above specifications (see "Nominal OD and Wall Thickness"). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains an output relay and an adjustable electronic retard. The relay is actuated when a flow of 3 gallons per minute (11,4 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. Afield installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC, and CSFM Listed Service Pressure: Up to 450 PSI (31 BAR) Flow Required for Alarm: 3.0 GPM (11,4 LPM) Maximum Surge: 18 FPS (5,5 m/s) Power Requirements: STANDBY: lOma at 120V AC or 1.5ma at 24V AC/DC ALARM: 40ma at 120V AC or 35ma at 24V AC/DC Contact Ratings: DPDT (Form C) 2 Amps at 0-30VDC or 0-125VAC resistive Conduit Entrances: 2 knockouts provided for 1/2' conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/1207, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Nominal OD and Wall Thickness: (60,3mm OD), 3,9mm to 4,5mm wall 2 1/2" (73,0mm OD), 4,8mm to 5,2mm wall 2 1/2" (76,1mm. OD), 4,3mm to 4,7mm wall (88,9mm OD), 5,0mm to 5,6mm wall (114,3mm OD), 5,4mm to 6,4mm wall Service use: Water mist systems where low flow for alarm is required. Optional: Cover Tamper Switch Kit, Stock No. 0090018 Installation See Fig. 1 These devices may be mounted on a horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" +1/8" -1/16" (32mm ± 2mm). The 3" (80mm) and 4" (100mm) devices require a hole with a diameter of 2" ± 1/8" (50mm ± 2mm). Clean the inside of the pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 20 ft-lbs. (27 n-m) of torque. See Fig. 1. The vane must not rub the inside of the pipe or bind in any way. Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 Phone: 800-325-3936/Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MFG. #5400999 - REV M PAGE 1 OF 2 5109 Fig. 1 DO DOE RE12I SEI.EDIOR 10 INSTALL. DRILL HOLE AS INDICATED. PIPE SIZE HOLE SIZE 2 to 2—I/2 I-1/4 + 1/8 - 1/18 (60 to 60mm) (33rm,, ± 2mm) 3* to 4m 2±1/8 (80 to 100mm) I (60mm * 2mm) DIRECtiWAlERON Fu 110H1ER NUTS ALTERNATELY 10 AN EAD(TUAL 20 Fr._..(27 n—m) OF TORQUE )4OUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTRIN OF WAIERFLOW ROLL PADDLE IN OFJ 762-30 RELAY ACTION NJM cON N.C. TJ 4/6 WIRE CONTROL PANEL CIRCUIT ____ END or UNE DETECTOR CIRCUIT FROM PANEL -4j RESISTOR OR II RETURN TO CONTROL PANEL 24V DC POWER r0 Ie 0 24VDCRELAY j 12SA24V CON. NO..N.C. SHOWN ENERGIZED NOTE: BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE DC DWG. #985—I BELL -TO] 066 660 I20024V. N.O.cOU.N CONTACTS I LOW VOLTAGE AC AUX. . CONTACTS I HIGH VOLTAGE P POTTER LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD Retard Adjustment The retard time is selected by turning the appropriate switches to the off position. Example: For 45 seconds turn switches 1, 2 and 3 to the off position. Approximate time is as follows: Switch Off Time in Sec. 1thru80n 0 1 15 1&2 30 l,2,&3 45 1,2,3,&4 60 1,2,3,4,&5 75 l,2,3,4,5,&6 90 7 not used 8 not used Fig. 2 Typical Electrical Connections Fig. 3 Switch Terminal Connections Clamping Plate Terminal s... C0 DWG# 923-3 I A CAUTION I When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Application Warning! Due to the possibility of unintended discharges caused by pressure surges, trapped au; or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Testing: The operation of the waterfiow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MFG. #5400999 - REV M PAGE 2 OF 2 5/08 MWSIMEWAIIINI Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve The AGF Model 1011A TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 101 1A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (3/4" to 2") with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: %" (2.8K), 7A6" (4.2K), ½' (5.6K), 17/32" (8.0K), %" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. [L1Lê SS-M1011A_V001 06/13 TESTaDRAlN5 is registered trademark of AGF Manufacturing Inc. LISTED 0 T'lEOU&M 11DAL8 He Model 1011 A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVED Factory Rated at 175 PSI with other setting available Dimensions SIZE A B C D E F G H 3/4" 79/16" 11/2" 241i6 3/8" 3/8" 113/16" 4A6' 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 7A6" 11/2" 2A6" 3 /8" 3/8" 113A6" 4A6" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 MM) 11/4" 715A6" 111A6" 29A6" 41/4" 35/8" 115/16" 59/16" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1 Wl 815/16" 113A6" 31/4" 51A6" 37/8" 25/8" 81/4" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815A6" 113A6" 31/4" 51/16" 3/8" 1 25/8" 81/4" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) The Model 1011 provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Model 1011 -Front View Model 1011 - Plan View Orifice Sizes 3/0, /16", 1/2", 17/33, /8" ELO* 3/4" ESFR*, and K25** Materials Handle................Steel Stem . .................. Rod Brass Ball ...................... C.P. Brass Body...................Bronze Valve Seat ..... ...... Impregnated Teflon® Indicator Plate .... Steel Relief Valve.........Bronze Bypass Fittings... Brass Bypass Tubing.... Nylobraid Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM MADE IN U.S.A. I AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 I / I A Phone: 610-240-4900 I Fax: 610-240-4906 www.testandraun.com Available on 11/4' to 2 size units only • **Available on 11/2' and 2" size units only Job Name: Architect: Engineer: Contractor: FireLock® Butterfly Valve \4tauIic Style 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12"/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®us FVdjS FL -PC B USIED G410001 104j/04 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.81 5662 Rev G updated 08/2016 © 2016 Victaulic company. All rights reserved. ..,4tauijc 1 _________________ victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve cULus FM Vds LPCB Size up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 100 up to 300psi/2068kPa up to 300psi/2O68kPa up to 300psi/2068kPa 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa up to 300psi/2068kPa I up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 MM upt0300ps1/2068kPa upt0300ps1/2068kPa n/a upto300ps1/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"I50 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"I200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASIM B-733 Seat: Grade 'E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TEE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 0 2— 8/50 —200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing o 10— 12/250-300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 /tauIic victaulic.com 4.0 DIMENSIONS Style 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 1 6.41 - - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 mm 76.1 3.000 3.77 2.28 7.54 1 - - 4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 1 108.0 117.6 73.2 223.8 - 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 - 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 1 160.0 65.5 39.7 mm 5.500 5.88 3.35 10.88 - 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 - 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 - - 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 I 65.5 159mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 1651mm 6.500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 165.1 1 149.4 97.5 289.1 10.4 191.0 1 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 1 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 - 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 - 205.7 228.6 NOTE Optional W/15mm tap available. Contact Victaulic for details. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com x.A-C-ta-uli,07 victaulic.com 5.0 PERFORMANCE Style 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/nn inches inches of pipe 2 2.375 6 50 60.3 1.8 2½ 2.875 6 65 73.0 1.8 76.1 mm 3 .000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm L 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6 .500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev G updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com \,Ltaulac victaulic.com 5.1 PERFORMANCE Style 705 Cv values for flow of water at +607/+160C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K values = Where: = Q2 Q = Flow (GPM) AP= Pressure Drop (psi) 0 = C x C= Flow Coefficient Q = x JAP Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches Cv mm mm 2 2.375 170 50 60.3 2½ 2.875 260 65 73.0 76.1 mm 3.000 76.1 260 3 3.500 80 88.9 440 4 4500 820 100 . 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133 mm 133 mm 1200 139.7 mm 5.500 139.7 1200 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 165.1 1800 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 9000 300 323.9 Where: 0 = Flow (m3/hr) LP = Pressure Drop (Bar) K = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K mm mm 2 2.375 50 60.3 147 2½ 2.875 225 65 73.0 76.1 mm 3.000 76.1 225 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7mm 5.500 139.7 1040 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 2 73. 0 12 12.750 7790 300 323.9 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victhulic.com 5 J Ac taUUiC tnrti Ilir ram 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S, f Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe ULLISIED JUNCT10N BOX CONDUIT CONDUIT CONNECTORS DIRE NUTS FIRE ALARM TO END-OF-LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR SUPERVISORY CIRCUIT Na COM, AVDC CO : 1 AND 51 J U , 0. 52 VOLTAGE SOURCE Switch 1 2 leads per terminI Switch 2,1 lead per tereninel NOTES The above diagram shows a connection between the common terminal (yellow — Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). BELL OR HORN 10.81 5662 Rev G updated 08/2016 © 2016 Victaulic Company. All rights reserved. t,ir+,,Ur ram JtauIic victaulic.com 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any Provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company, All rights reserved. victaulic.com 7 'J1tauIic MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT APPROVED 175 PSI PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON A126 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5) STAINLESS STEEL 6 GASKET NON ASBESTOS 12 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WT (LBS) 1/2 (15mm) MVC150050 250°F 1/2 NPT 1/2' NPT 1/16" 5-1/2 3/4" (20mm) MVC150075 250°F 3/4" NPT 1/2" NPT 1/16" 5-1/2 1" (25mm) MVC15O100 250°F 1" NPT 1/2" NPT 1/16" 5-1/2 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: I REV. 1 PART NUMBER UPDATED DATE 2/28/2017 2323 W. HUBBARD ST. CHICAGO, IL 60612 I\'qf TEL: 312-738-3800 1et r FAX: 312-738-0415 I for pipes in motion MODEL MVC-15 METRAVENT AUTOMATIC AIR VENT SCALE: IDRAWING NUMBER: MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT MAX WORKING PRESSURE 300 PSI @ 150°F 260 PSI @250°F PART PART NAME MATERIAL PART PART NAME MATERIAL 1 BODY CAST IRON A126 7 COVER BOLT CARBON STEEL 2 COVER CAST IRON Al 26 8 FLOAT ARM STAINLESS STEEL 3 LEVER FRAME STAINLESS STEEL 9 ORIFICE BUTTON FLUOROELASTOMER 4 SEAT STAINLESS STEEL 10 PIVOT PIN/RETAINER STAINLESS STEEL 5 FLOAT STAINLESS STEEL 11 PIPE PLUG (0.5) STAINLESS STEEL 6 GASKET NON ASBESTOS k-1 2 LOCATOR STAINLESS STEEL QTY SIZE PART NUMBER MAX TEMP INLET SIZE OUTLET SIZE ORIFICE SIZE WI (LBS) 1/2 (15mm) MVC300050 250°F 1/2 NPT 1/2" NPT 1/16" 8 3/4' (20mm) MVC300075 250°F 3/4 NPT 1/2" NPT 1/16' 8 1" (25mm) MVC300100 250°F 1 NPT 1/2 NPT 1/16" 8 NSF 372 - LEAD FREE The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Material complies with state codes and standards, where applicable, requiring reduced lead content. CUSTOMER: PROJECT: ENGINEER: I REV. 1 I PART NUMBER UPDATED DATE 2/28/2017 2323 W. HUBBARD ST. CHICAGO, IL 60612 IV Vi q f TEL: 312-738-3800 et r FAX: 312-738-0415 pr pipes in motion MODEL MVC-30 METRAVENT AUTOMATIC AIR VENT SCALE: I DRAWING NUMBER: &~ur ~ee wa yBrassVaIve 1/4" IPS UL/ULC Listed Description The 1/4" IPS three-way female threaded valve is used to facili- tate the installation of sprinkler system pressure gauges. The valve provides for one inlet and two outlets. This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4" IPS pipe plug.) Installation Specifications Materials: Seat- Brass Body- Brass Handwheel - Iron Sizes: 1/4" IPS Working Pressure: 400 WOG Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation allows for a 1/4" IPS nipple between the valve and the water supply being measured. This assures there will be ad- equate spacing for the sprin- kler system gauge from the riser. Use either PTFE Pipe Thread Sealing Tape or a suit- able pipe thread sealant such as PipeFit® Thread Sealant Paste with PTFE when in- stalling the valve. DO NOT OVERTIGHTEN THREADS. OVERTIGHTENING MAY CAUSE VALVE FAILURE. *UL/ULC Listed 2R97 ©2003-2007 Fire Protection Products, Inc Fire Protection Products, Inc. F P P Ile 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com f PKM O~L_ Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipef it® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC'" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com -u I4 MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPPI®, LubeRtO are registered trademarks of Fire Protection Products, Inc. FBC"', BlazeMastete, FlowGuard GoIcP and Corzan® are registered trademarks of Noveon IP Holdings Corp. 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: sales@sandiegoseaI.com • VISIT US AT: www.sandiegoseal.com PTFE Thread Sealant Tapes Made in the USA ir thread sealant tape breaks clean without shredding warping, identifying it as a product that can be trusted perform reliably when the job is completed and the ?ssure is on. Standard Grade Our standard grade PTFE Thread Sealant Tape is for those applications that do not require the sealing properties of a I -- - premium grade thread sealant. This is intended to be used for - j general purpose sealing in pipe threads. The standard ' ) density virgin PTFE sealant tape permits quick, clean, economical sealing of male pipe threads of all sizes and ¼ - reduces the risk of system contamination common with liquid and paste sealants. It is effective and efficient so you can use less tape. Tears cleanly.. .seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. PTFE Thread Sealant Tapes isk of system contamination common with liquid and paste sealants. Our full density premium and gas line tapes meet Mil Spec A-A 58092 for liquid & gaseous oxygen applications. The self-lubricating quality of this unsintered tape nakes joints easy to assemble and disassemble. Totally maintenance free, full density PTFE thread sealant tape is irtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-40°C) to +500°F (+260°C), and pressures from a hard vacuum to 10,000 PSI. Typical properties of PTFE thread sealant tape are as follows: Typical Properties Grade Standard Grade Premium Grade Premium Grade I Premium Grade - Yellow IStandard Densyj-ligh Density Iuii Density IFuD Density Description I 1 i he economical choice pore sealing power . [ Maximum sealing u rower. So efficient ou can use less ape. omplies with certain uilding codes requiring ellow, thicker, more ense tape for gas lervice lines Color }Nhite or colors jNhite or colors White or colors frellow Density tandard 0.5 to 0.7 tandard 1.0 to 1.2 Istandard 1.5 tandard 1.6 Thickness JJ.003" to 0.0035° 13.003" to 0.0035" E.003" to 0.0035" I Standard Widths & Lengths /" x 260" /" x 520" /" x 1296" /2" x 260" /2" x 520" 2" x 1296" >" x 260" /" x 520" Y4" x 1296" 1" x 260" 1" x 520" 1" x 1296" Quantity 144 rolls per box 144 rolls per ox 144 rolls per box i Typical F1tUse Nhite All industrial applications. Made from virgin PTFE Dink For use in plumbing and pipe fittings (water and steam lines) 3ray For stainless steel pipe/fittings 3reen For oxygen applications (ellow For gas line use SAN DIEGO SEAL, INC 7635 RONSON ROAD • SAN DIEGO, CALIFORNIA 92111 TEL: 858-278-3270 9 FAX: 858-278-2950 E-MAIL: salessandiegoseaI.com 9 VISIT US AT: www.sandiegoseal.com