HomeMy WebLinkAbout2200 FARADAY AVE; ; AS050022; Permit10/27/21, 8:56 AM AS050022 Permit Data
City of Carlsbad
Sprinkler Permit
Job Address: 2200 FARADAY AV
Permit Type: SPRINK
Parcel No: 2121203700
Lot #: 0
Reference No.:
PC #:
Permit No: AS050022
Status: ISSUED
Applied 3/2/2005
Approved: 3/4/2005
Issued: 3/4/2005
Inspector:
Project Title: ROCKSTAR, 2ND FLOOR T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant:
WESTERN FIRE PROTECTION
12232 THATCHER CT
P0 WAY CA
858-513-4949
Owner:
E Q B P-I L L C
ATTN: CHAD CARPENTER
800 SILVERADO ST #300
LA JOLLA CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
115 0 115 0
1/1
Bulletin 111
Reliable Model G
Recessed
Automatic
Sprinkler
CD
-
-
The Most Compact,
Attractive and Easily
Installed Sprinkler
Ever Designed
Features
11/2" Total adjustment provided by
adjustable inlet versions.
½" Total adjustment provided by
economical standard inlet version.
Adjustable inlet version available with
either 1" NPT male or female threads
eliminating costly reducing coupling.
Small diameter escutcheon.
Available in brass, chrome or white finish.
Multiple orifice sizes for design flexibility.
Listed by. Underwriters Laboratories
Inc. & Underwriters' Laboratories of
Canada. Approved by Factory Mutual
Research Corp. & Loss Prevention
Council, NYC BS&A No. 587-75-SA.
Today's modern buildings demand that a sprinkler not
only provide the best fire protection but also achieve an
attractive appearance. Reliable's Model G Recessed
Sprinkler meets both criteria. It combines the fire fighting
capability of a proven sprinkler with the smallest practi-
cable recessing unit. Its small profile does not disrupt the
overhead aesthetics, and yet one vertical glance upward
gives a visual assurance of the finest in fire protection,
an automatic sprinkler system.
The Model C Recessed Sprinkler's threaded two—piece
construction makes initial field installation a very easy
task. It allows ceilings panels to be removed without
shutting down the fire protection thus facilitating mainte-
nance of above ceiling services. The adjustable one inch
NPT inlet versions have one and one half inches of
adjustment which eliminates both the normally required
reducing coupling and the need to accurately cut drop
nipples. This sprinkler can be adjusted after the ceiling
is in place and even while the system is pressurized
eliminating the final corrections to pipe hangers or ceil-
ings that might otherwise be required.
The Reliable Model G Automatic Sprinkler is the heart
of the Recessed Sprinkler. This sprinkler utilizes the
center strut solder in compression principle of construc-
tion. The fusible alloy, captured in the cylinder of a small
solder capsule by a stainless steel ball, acts as the trigger
of the sprinkler. When the fusible alloy melts, the sprin-
klers operating parts spring free from the sprinkler clear-
ing the waterway and allowing the deflector to distribute
the discharging water.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New Yorki 0552
1SF 00 (1800
1ITi1 rT
l _11114j JIIJIL J
1
NOT I
R(Ouc(0—.
CE OF nMAG 10
d1 Ti
WE OF CrIt G
SPRINKLER
CEILING , 03V CUP
I12 (5(0(0(00 - *4(7. ADJUSTM(NI
.—lSYS TIM DROP I048PL(
!T 1
I' "LEI DROP NIPPLE ro Mumic 8.00. 005STM(0T
CEILING COP 03 851 •SSER8L
CEILING
7/2 (DCUI00(0'I 5/8
MILL 4041578(01
,00 5/6 FOR 7'(NDLC 00
3/8 71W & 17132 080CE
I - - - - - - - 1
-
11J] ADJUSMEN,
L J I
[75)
0,0(051005 0 P00(000(0'S IN MILUMEIFRI
Sprinkler Maximum Ceiling
Classification Rating Temperature
°F "C "F
Ordinary 135 57 100 38
Ordinary 165 74 100 38
Intermediate 212 100 150 66
Standard
Sprinkler
Finishes0
Escutcheon
Bronze Brass
Bronze White Painted
Chrome Bright Chrome Bright
Chrome Bright Chrome Satin
Chrome Bright White Painted
Bright Brass Plated Bright Brass Plated
Black Plated Black Plated
White Painted (2) Polyester Coated
Polyester Coated (2)
IF-
Special Finishes upon request. ) Only frame, deflector and cap are plated.
Only frame and deflector are painted or coated, operating parts
are chrome plated. UL Listed and MEA Approved only.
Sprinkler Inlet
Total
Adjustment * Nominal Orifice
K Factor
U.S. Metric Thread
Approval
Organizations
Non-Adjustable 1/2" 1/2 (15mm) 5.62 81.0 l/2" NPT (R1/2) 12,3.4,5
Non-Adjustable 1/2" 7/16"M 4.24 61.0 1/2" NPT (R1/2) 1,3.4
Non-Adjustable 1/2" /8" 1) 2.82 40.6 1/2" NPT (R'/2) 1,3,4
Non-Adjustable 1/2" /32" (1) 7.96 114.7 1/2" NPT (R1/2) 1,3
Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male or Female 1,2,3,4
Adjustable 11/2 /16 (1) 4.24 61.0 1" NPT Male or Female 1,3,4
Adjustable 11/2" 3/s" (1) 2.75 39.2 1" NPT Male or Female 1,3,4
Adjustable 11/2" 15mm 1 5.53 79.7 Al Male or Female 5
"Sprinkler escutcheon provides ½" of the total adjustment. Adjustable inlets, when used, provide 1" of the total adjustment.
(1) Identified by pintle extending above the deflector
NPT Threads per ANSI B2.1
Ri Threads per ISO 7/1-1982 (BS 21:1973)
Approval Organizations
1.Underwriters Laboratories Inc.
Factory Mutual Research Corp.
Light Hazard Occupancies-No Limitations
Ordinary Hazard Occupancies-Groups 1&2, Wet Systems Only
Underwriters Laboratories of Canada
NYC BS & A No. 587-75-SA
Loss Prevention Council
Ordering Information s XLH, CHI and OHII Occupancies Only
Specify NYC MEA 258-93-F
Temperature Rating 5. Sprinkler Type: Either
Nominal Orifice Non-Adjustable Inlet (Fig. 1) Nota: Unless otherwise indicated, ordinary hazard approvals are
Sprinkler Finish 1" Male Adjustable Inlet (Fl? 2) without limitations. 7/16" & 3/8" orifice sprinklers are limited to light
Escutcheon Finish 1" Female Adjustable Inlet (Fig.3) hazard occupancies.
½" NPT Non-Adjustable Inlet 1" NPT Male-Adjustable Inlet 1" NPT Female-Adjustable Inlet
Figure 1 Figure 2 Figure 3
2.
Bulletin 154
HIM11able
Model G4A
Concealed
Automatic Sprinkler Cn
The Concealer®
A Concealed Sprinkler With a ½" or 11/2" Adjustment
Features
½" Cover Plate Adjustment
Simple sturdy cover attachment
Smooth aesthetic ceiling profile
Factory installed protective cap
Available in brass, chrome or
black plated and white painted
finishes
Ordinary temperature ratinq
Multiple orifices for design flexibility
Threaded coverplate does not require
clips or springs
Listed by Underwriters Laboratories Inc.
and Underwriters' Laboratories of
Canada, NYC MEA 258-93-E. - Quick
Response Sprinkler. Approved by
Factory Mutual Research Corp.—
Standard Response Sprinkler.
U.S. Patent number 4,880,063
Application
The Relble Model G4A
ConcealerR is the most ver-
satile quick response con-
cealed sprinkler available. It
provides the best form of fire
protection while offering an
attractive appearance and
½ inch of cover adjustment
for ease of installation. The
small diameter cover plate is
easily and positively at-
tached and blends into the ceiling, concealing the
most dependable fire protection available, an auto-
matic sprinkler system.
The Model G4A Concealer R is designed for use
where aesthetic appearance is important. Offices,
hospitals, motels and restaurants are but a few of the
applications where is can be used. It is available in
different orifice sizes allowing the designer to opti-
mize system performance, thereby achieving a very
efficient installation.
:.
:.
The Model G4A concealer® is a UL Listed Quick
Response Concealed sprinkler intended for use in
accordance with NFPA 13. FM Approves this sprin-
kler as a standard response concealed sprinkler in-
tended for use in accordance with FM Loss
Prevention Data Sheet 2-8N.
Product Description
The Reliable Model G4A Concealer® uses a
proven quick response fusible element in a standard
style sprinkler frame with a drop-down deflector. This
assembly is recessed into the ceiling and concealed
by a flat cover plate. The cover plate and sprinkler
cup assemblies are attached using a strong
threaded engagement. This threaded engagement
provides 1/2" of cover adjustment. The cover plate is
attached to the skirt using 135°F ordinary tempera-
ture classification solder.
When the ceiling temperature rises, the solder
holding the cover plate melts, allowing the release of
this part and thus exposing the sprinkler inside to the
rising ambient temperature.
The subsequent fusing of the element opens the
waterway and causes the deflector to distribute the
water. Any secure engagement between the cover
plate and cup will assure that the drop-down deflec-
tor is properly located below the ceiling.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552
It
Ordering Information
Sprinkler Model
Nominal Orifice
Cover Plate Finish
Inlet Type
Cover Plate Finishes(')")
White Paint
Bronze
Bright Brass Plated
Chrome Plated
Black Plated
'Other finishes and colors are
available on special order.
Consult factory for details.
`FM Approval of the painted
finish is limited to white and off
white paint. All plated finishes
are FM Approved.
ULI Listing Category
Sprinklers, Automatic and
Open
Quick Response Sprinkler
ULI Guide Number
VNIV
Model G4 Sprinkler Wrench
Installation Approval Organizations
The wrench has drive tangs which insert into the cup
tioned into the sprinkler/cup assembly until the wrench
tangs engage the drive slots in the top of the cup (there
then tightened into the pipe fitting. When inserting or re-
have positive pressure in the space above.
sprinkler is easily installed with the Model G4 Wrench.
slots. When installing a sprinkler the wrench is first posi-
are two sets of drive slots in the cup). The sprinkler is
moving the wrench from the sprinkler/cup assembly
care should be taken to prevent damage to the sprinkler.
SPRINKLER/CUP ASSEMBLY. Final adjustment of the
cover is made by hand turning the cover in the clock-
DO NOT WRENCH ON ANY OTHER PART OF THE
After a 2% inch diameter hole is cut in the ceiling, the
Do not install the G4A Concealer® in ceilings which
Underwriters' Laboratories of
Factory Mutual Research Corp.
1. Underwriters Laboratories, Inc.
NYC MEA 258-93-E
- Quick Response
- Quick Response
- Standard Response
- Quick Response
Canada
Light Hazard
Ordinary Hazard
Occupancies -
No Limitations
Occupancies Groups 1
& 2, Wet Systems Only
wise direction until it is tight against the ceiling. Note: Approvals are for light and
ordinary hazard, except for small A protective cap is provided to protect the drop-down orifice sprinklers which are lim- sprinkler deflector from damage which could occur dur- ited to light hazard. The cup and ing construction before the cover plate is installed. The skirt are fabricated from plated cap is factory installed inside the sprinkler cup. Remove steel and are intended for interior cap to install sprinkler, then re-install cap until the cover non-corrosive applications
plate is installed. Note: Paint or any other coat-
ings applied over the factory fin-
ish will void all approvals and
warranties. Standard Temperatures
Classification Sprinkler Cover Plate Max. Ceiling Temp.
Ordinary 1651F/741C 135°F/571C 1001F/381C
Installation Data
Sprinkler Inlet 1 Total
Adjustment
Nominal
Orifice
"K" Factor I Thread Metric
Approvals us
Non Adjustable ½" ½" 5.62 81.0 I 112" NPT 12,3,4
Non Adjustable ½" 7/ /16 4.24 61.0 1/2 "NPT 1,2,4
Non Adjustable ½" %" 2.82 40.6 1/2 "NPT 1,2,3,4
Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male orFemale 1,2,4
Adjustable 11/2,, 7 //16,, 4.24 61.0 1" NPT Male or Female 1,2,4
rfi
JlII I l ILJ
SPMNKLER CO,
0 V8
OOM
~USWENT L_
½" NPT Non Adjustable Inlet 1" NPT Male-Adjustable Inlet 1" NPT Female-Adjustable Inlet
Figure 1 Figure 2 Figure 3
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual
Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and propertyfor over 70 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
AGN The Reliable Automatic Sprinkler Co., Inc. The Pape
(800) 431-1588 Sales Offices Relinbld (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 668-3470 Corporate Offices
w.reIiablesprinkIer.com Internet Address E.G. Printed in U.S.A 11/99. P/N 9999970150