HomeMy WebLinkAbout2200 FARADAY AVE; ; AS050022; Permit10/27/21, 8:56 AM AS050022 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2200 FARADAY AV Permit Type: SPRINK Parcel No: 2121203700 Lot #: 0 Reference No.: PC #: Permit No: AS050022 Status: ISSUED Applied 3/2/2005 Approved: 3/4/2005 Issued: 3/4/2005 Inspector: Project Title: ROCKSTAR, 2ND FLOOR T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 12232 THATCHER CT P0 WAY CA 858-513-4949 Owner: E Q B P-I L L C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 1/1 Bulletin 111 Reliable Model G Recessed Automatic Sprinkler CD - - The Most Compact, Attractive and Easily Installed Sprinkler Ever Designed Features 11/2" Total adjustment provided by adjustable inlet versions. ½" Total adjustment provided by economical standard inlet version. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. Small diameter escutcheon. Available in brass, chrome or white finish. Multiple orifice sizes for design flexibility. Listed by. Underwriters Laboratories Inc. & Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corp. & Loss Prevention Council, NYC BS&A No. 587-75-SA. Today's modern buildings demand that a sprinkler not only provide the best fire protection but also achieve an attractive appearance. Reliable's Model G Recessed Sprinkler meets both criteria. It combines the fire fighting capability of a proven sprinkler with the smallest practi- cable recessing unit. Its small profile does not disrupt the overhead aesthetics, and yet one vertical glance upward gives a visual assurance of the finest in fire protection, an automatic sprinkler system. The Model C Recessed Sprinkler's threaded two—piece construction makes initial field installation a very easy task. It allows ceilings panels to be removed without shutting down the fire protection thus facilitating mainte- nance of above ceiling services. The adjustable one inch NPT inlet versions have one and one half inches of adjustment which eliminates both the normally required reducing coupling and the need to accurately cut drop nipples. This sprinkler can be adjusted after the ceiling is in place and even while the system is pressurized eliminating the final corrections to pipe hangers or ceil- ings that might otherwise be required. The Reliable Model G Automatic Sprinkler is the heart of the Recessed Sprinkler. This sprinkler utilizes the center strut solder in compression principle of construc- tion. The fusible alloy, captured in the cylinder of a small solder capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible alloy melts, the sprin- klers operating parts spring free from the sprinkler clear- ing the waterway and allowing the deflector to distribute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New Yorki 0552 1SF 00 (1800 1ITi1 rT l _11114j JIIJIL J 1 NOT I R(Ouc(0—. CE OF nMAG 10 d1 Ti WE OF CrIt G SPRINKLER CEILING , 03V CUP I12 (5(0(0(00 - *4(7. ADJUSTM(NI .—lSYS TIM DROP I048PL( !T 1 I' "LEI DROP NIPPLE ro Mumic 8.00. 005STM(0T CEILING COP 03 851 •SSER8L CEILING 7/2 (DCUI00(0'I 5/8 MILL 4041578(01 ,00 5/6 FOR 7'(NDLC 00 3/8 71W & 17132 080CE I - - - - - - - 1 - 11J] ADJUSMEN, L J I [75) 0,0(051005 0 P00(000(0'S IN MILUMEIFRI Sprinkler Maximum Ceiling Classification Rating Temperature °F "C "F Ordinary 135 57 100 38 Ordinary 165 74 100 38 Intermediate 212 100 150 66 Standard Sprinkler Finishes0 Escutcheon Bronze Brass Bronze White Painted Chrome Bright Chrome Bright Chrome Bright Chrome Satin Chrome Bright White Painted Bright Brass Plated Bright Brass Plated Black Plated Black Plated White Painted (2) Polyester Coated Polyester Coated (2) IF- Special Finishes upon request. ) Only frame, deflector and cap are plated. Only frame and deflector are painted or coated, operating parts are chrome plated. UL Listed and MEA Approved only. Sprinkler Inlet Total Adjustment * Nominal Orifice K Factor U.S. Metric Thread Approval Organizations Non-Adjustable 1/2" 1/2 (15mm) 5.62 81.0 l/2" NPT (R1/2) 12,3.4,5 Non-Adjustable 1/2" 7/16"M 4.24 61.0 1/2" NPT (R1/2) 1,3.4 Non-Adjustable 1/2" /8" 1) 2.82 40.6 1/2" NPT (R'/2) 1,3,4 Non-Adjustable 1/2" /32" (1) 7.96 114.7 1/2" NPT (R1/2) 1,3 Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male or Female 1,2,3,4 Adjustable 11/2 /16 (1) 4.24 61.0 1" NPT Male or Female 1,3,4 Adjustable 11/2" 3/s" (1) 2.75 39.2 1" NPT Male or Female 1,3,4 Adjustable 11/2" 15mm 1 5.53 79.7 Al Male or Female 5 "Sprinkler escutcheon provides ½" of the total adjustment. Adjustable inlets, when used, provide 1" of the total adjustment. (1) Identified by pintle extending above the deflector NPT Threads per ANSI B2.1 Ri Threads per ISO 7/1-1982 (BS 21:1973) Approval Organizations 1.Underwriters Laboratories Inc. Factory Mutual Research Corp. Light Hazard Occupancies-No Limitations Ordinary Hazard Occupancies-Groups 1&2, Wet Systems Only Underwriters Laboratories of Canada NYC BS & A No. 587-75-SA Loss Prevention Council Ordering Information s XLH, CHI and OHII Occupancies Only Specify NYC MEA 258-93-F Temperature Rating 5. Sprinkler Type: Either Nominal Orifice Non-Adjustable Inlet (Fig. 1) Nota: Unless otherwise indicated, ordinary hazard approvals are Sprinkler Finish 1" Male Adjustable Inlet (Fl? 2) without limitations. 7/16" & 3/8" orifice sprinklers are limited to light Escutcheon Finish 1" Female Adjustable Inlet (Fig.3) hazard occupancies. ½" NPT Non-Adjustable Inlet 1" NPT Male-Adjustable Inlet 1" NPT Female-Adjustable Inlet Figure 1 Figure 2 Figure 3 2. Bulletin 154 HIM11able Model G4A Concealed Automatic Sprinkler Cn The Concealer® A Concealed Sprinkler With a ½" or 11/2" Adjustment Features ½" Cover Plate Adjustment Simple sturdy cover attachment Smooth aesthetic ceiling profile Factory installed protective cap Available in brass, chrome or black plated and white painted finishes Ordinary temperature ratinq Multiple orifices for design flexibility Threaded coverplate does not require clips or springs Listed by Underwriters Laboratories Inc. and Underwriters' Laboratories of Canada, NYC MEA 258-93-E. - Quick Response Sprinkler. Approved by Factory Mutual Research Corp.— Standard Response Sprinkler. U.S. Patent number 4,880,063 Application The Relble Model G4A ConcealerR is the most ver- satile quick response con- cealed sprinkler available. It provides the best form of fire protection while offering an attractive appearance and ½ inch of cover adjustment for ease of installation. The small diameter cover plate is easily and positively at- tached and blends into the ceiling, concealing the most dependable fire protection available, an auto- matic sprinkler system. The Model G4A Concealer R is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where is can be used. It is available in different orifice sizes allowing the designer to opti- mize system performance, thereby achieving a very efficient installation. :. :. The Model G4A concealer® is a UL Listed Quick Response Concealed sprinkler intended for use in accordance with NFPA 13. FM Approves this sprin- kler as a standard response concealed sprinkler in- tended for use in accordance with FM Loss Prevention Data Sheet 2-8N. Product Description The Reliable Model G4A Concealer® uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate and sprinkler cup assemblies are attached using a strong threaded engagement. This threaded engagement provides 1/2" of cover adjustment. The cover plate is attached to the skirt using 135°F ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflec- tor is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552 It Ordering Information Sprinkler Model Nominal Orifice Cover Plate Finish Inlet Type Cover Plate Finishes(')") White Paint Bronze Bright Brass Plated Chrome Plated Black Plated 'Other finishes and colors are available on special order. Consult factory for details. `FM Approval of the painted finish is limited to white and off white paint. All plated finishes are FM Approved. ULI Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler ULI Guide Number VNIV Model G4 Sprinkler Wrench Installation Approval Organizations The wrench has drive tangs which insert into the cup tioned into the sprinkler/cup assembly until the wrench tangs engage the drive slots in the top of the cup (there then tightened into the pipe fitting. When inserting or re- have positive pressure in the space above. sprinkler is easily installed with the Model G4 Wrench. slots. When installing a sprinkler the wrench is first posi- are two sets of drive slots in the cup). The sprinkler is moving the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. SPRINKLER/CUP ASSEMBLY. Final adjustment of the cover is made by hand turning the cover in the clock- DO NOT WRENCH ON ANY OTHER PART OF THE After a 2% inch diameter hole is cut in the ceiling, the Do not install the G4A Concealer® in ceilings which Underwriters' Laboratories of Factory Mutual Research Corp. 1. Underwriters Laboratories, Inc. NYC MEA 258-93-E - Quick Response - Quick Response - Standard Response - Quick Response Canada Light Hazard Ordinary Hazard Occupancies - No Limitations Occupancies Groups 1 & 2, Wet Systems Only wise direction until it is tight against the ceiling. Note: Approvals are for light and ordinary hazard, except for small A protective cap is provided to protect the drop-down orifice sprinklers which are lim- sprinkler deflector from damage which could occur dur- ited to light hazard. The cup and ing construction before the cover plate is installed. The skirt are fabricated from plated cap is factory installed inside the sprinkler cup. Remove steel and are intended for interior cap to install sprinkler, then re-install cap until the cover non-corrosive applications plate is installed. Note: Paint or any other coat- ings applied over the factory fin- ish will void all approvals and warranties. Standard Temperatures Classification Sprinkler Cover Plate Max. Ceiling Temp. Ordinary 1651F/741C 135°F/571C 1001F/381C Installation Data Sprinkler Inlet 1 Total Adjustment Nominal Orifice "K" Factor I Thread Metric Approvals us Non Adjustable ½" ½" 5.62 81.0 I 112" NPT 12,3,4 Non Adjustable ½" 7/ /16 4.24 61.0 1/2 "NPT 1,2,4 Non Adjustable ½" %" 2.82 40.6 1/2 "NPT 1,2,3,4 Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male orFemale 1,2,4 Adjustable 11/2,, 7 //16,, 4.24 61.0 1" NPT Male or Female 1,2,4 rfi JlII I l ILJ SPMNKLER CO, 0 V8 OOM ~USWENT L_ ½" NPT Non Adjustable Inlet 1" NPT Male-Adjustable Inlet 1" NPT Female-Adjustable Inlet Figure 1 Figure 2 Figure 3 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and propertyfor over 70 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by AGN The Reliable Automatic Sprinkler Co., Inc. The Pape (800) 431-1588 Sales Offices Relinbld (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 668-3470 Corporate Offices w.reIiablesprinkIer.com Internet Address E.G. Printed in U.S.A 11/99. P/N 9999970150