Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; FA050085; Permit10/27/21, 8:57 AM FA050085 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2200 FARADAY AV Permit Type: FALARM Parcel No: 2121203700 Lot #: 0 Permit No: FA050085 Status: APPROVED Applied 9/19/2005 Approved: 9/19/2005 Reference No.: Issued: 9/19/2005 PC #: Inspector: Project Title: ROCKSTAR 2 FIRE ALARM INSPECTIONS @ $60.00 EA Applicant: ALARMS UNLIMITED, INC. 4584 PARK BL. SAN DIEGO, CA 619-297-4500 Owner: E Q B P-I L L C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA Fees ($) Add'I Fees ($) Total ($) LBalance_($) 120 0 120 0 1/1 2200 FARADAY 2200 FARADAY AVE CARLSBAD, CA 92008 Fire Alarm Submittal 09/15/05 Submitted By; ALARMS UNLIMITED 4584 PARK BLVD San Diego, CA. 92116 License #411233/Type CIO 2200 FARADAY Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# S Silent Knight 7170-0559:144 Silent Knight 7170-0559:144 Silent Knight 7272-0559:129 Silent Knight 7300-0559:132 Silent Knight 7150-0559:136 System Sensor 7135-1653:163 Fire Alarm Panel 5700 Fire Alarm Annunciator 5860 Smoke Detector SD505-APS Addressable Input Module SD500-AIM Manual Pull Station SDSOO-PS Horn/Strobe 15cd P1224MCW Connection to existing Waterfiow Switches Connecetion to existing PITS & OS&Y Switches Wire 18l2Cond. (Initiation) Atlas Cable 7161-0972:100 Wire 14/2Cond. (Indicating) Atlas Cable 7161-0972:100 S lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable solution. 0 lntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The lntelliKnight 5700 performs drift compensation and calibration checks on each of the sensors in the system. The basic lntelliKnight 5700 system can be enhanced by adding modules such as the Remote Annunciator, the Serial/Parallel Interface (for printing system reports), and an Intelligent Power Module. The Model 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Up to 50 addressable points. Up to 125 zones and 125 output groups. Uses standard wire—no shielded or twisted pair required. Built-in digital communicator. Central station reporting by Point or by Zone. Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC. Distributed, intelligent power. Drift compensation. 13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs. Notification circuits can be configured as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power. Built-in synchronization for appliances from Gentex®, Faraday, System Sensor® and Wheelock®. Built-in annunciator with 80-character LCD display. RS-485 bus provides communication to system accessories. Up or Download programming, event history, or detector status via remote or direct connection. Built-in RS-232 interface for programming via PC. Built-in Form C trouble relay rated at 2.5 amps at 24 VDC. Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC. Approvals: UL Listed / NFPA 72 (File No. S2766) -Central Station -DACT -Local Protective Signalling System -Water Deluge Releasing Service CSFM Listed MEA Approved 429-92-X Vol. XVI Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A at 24 VDC 2.5 amps at 24 VDC of power-limited notification power Standby Current: 160 mA Alarm Current: 330 mA Notification/Aux power circuits: 2.5 amps of power-limited power per circuit at 24 VDC. Model 5700 Mechanical Specifications: Dimensions: 12-3/4W x 15-1/8'H x 3-3/8D (32.39 x 38.42 x 8.57 cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) D SILENT KNIGHT by Honeywell 5700 $058 5.DTS SDSOS.AOHR S0500.PS $0505.AOH SLC Sensor Devices SD505-APS Addressable photoelectric smoke detector. 5D505-AHS Addressable heat sensor. SD505-6AB Six inch base designed for use with detector head models SD505-APS,and SD505-AHS. 5D505-61B Short circuit isolator base for 5D505-AHS, and SD505-APS detectors. 5D505-ADH Duct Housing. Detects smoke in HVAC ducts. Use with SD505-APS. 5D505-ADHR/DTS Addressable Duct smoke detector with built- in relay module detects products of combustion present in air moving through an HVAC system. Provides form C alarm contact. The 5D505-ADHR is compatible with the 5D505-DTS, which provides remote annunciation and testing capabilities for the SD505-ADHR. Use with SD505-APS. 5D500-PS/PSDA Addressable Pull Station with visible LED. Intelligent SLC Modules SD500-AIM Dry Contact Input Module. Designed to used with normally open dry contacts. Mounts in a 4 inch square electrical box. It features an indicator LED to show alarm status and a coverplate. - SD500-MlM Mini Dry Contact Input Module. A miniature version of the addressable input module which is designed to be used with pull stations and other normally open dry contact inputs where a smaller size is desired. SD500-ARM Addressable Relay Module. Features 2 Form C output relays, designed to mount on a 4 inch square electrical box. Provides indicator LED to show output status and comes with a coverplate. 5D500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500- LEDs can be used per system. SD500-LIM Addressable short circuit isolator module for SLC devices S-BUS Accessories The following items listed are devices that connected to the lntelliKnight's RS-485 Bus 5860 Remote Fire Annunciator The 5860 features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820. The system can be fully programmed and operated from any remote annunciator. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5496 Intelligent Power Module The 5496 is a 6 amp.notification power expander that provides four additional power-limited notification appliance circuit. 5865-3 and 5865-4 Remote LED - Annunciator Features 30 Programmable LEDs (15 red ard 15 yellow) outputs and piëzo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 General purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Gateway Module Has one parallel and one RS-232 serial port for connecting any standard IBM-compatible printer to the lntelliKnight system. Interfaces with building control system. SKSS Silent Knight Software Suite 5660 Up Download Software User-friendly, WindowsTM software for remote programming of the lntelliKnight panel using a PC. 5670 Facility Management Software Powerful end-user software allows viewing of detector status and event history via modem or direct connection. El Milo 83 i 503 I Use the 5800 to control up to4 I - - Rsu,w*nIto4. 5883 Robe Intorhoce Modules -> 5496 DSILENT KNIGHT I by Honeywell 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350392 Rev. B, 10/04 Copyright © 2004 Silent Knight S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 717040559:144 Page 1 of I CATEGORY: Control Unit (High-Rise) USTEE: Silent Knight Security, 7550 Meridian Circle #100, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 *FA)( (763) 391-5464 DESIGN: Models lFP-50 and 5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: RATING: INSTALLATION: IFP-50. 5700 7628 5860/5860R/RA-I000 5897 5496 5824 5865-I5965-4 5880 5883 SD500-LIM 5D505-61 B RA-100 3158 5220 120 VAC Primary, 24 VDC Secondary Control Units EOL Resistor Annunciator Power Supply Power Module Serial/Parallel Interface LED Annunciator LED 10 Module Relay Interface Board Line Isolation Module Isolation Base Remote Annunciator Reverse Polarity Module Direct Connect Module In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number, electrical rating, and UL label. APPROVAL Listed as control units for use In high-rise structures when used In conjunction with Model SKE- 360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), E.VAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102): EVX-2ZA or EVX4Z Zone Splitters (CSFM Listing No. 06912- 1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911- 1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and Indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm slonal). the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 05-28-2004 This Rating is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet installation Instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 S Authorized By: DIANE K. A REND1 Senior Deputy Program Manager [T Addressable Photoelectric Type ;dl Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 100°F (0°C to 50°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensi ng Air Velocity: 0 - 300 FPM Compatible Bases: 50505-6AB (Sold Separately) (6" Base) 5D505-4AB (4" Base) D SILENT KNIGHT ® A Honeywell Company Model SD505-APS Analog I Addressable Photoelectric Type 0 Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the 0 detector and light is reflected from the smoke particles to the receiving element. Eel 0 Model SD505-APS Addressable Photoelectric Type Smoke Detector • Engineering Specifications - The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 0 Diameter = 5-15/16" Diameter = 3-15/16" i4 4 Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) D SILENT .- - KNIGHT ® A Honeywell Company 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350225, Rev. 02/004 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com copyright © 2004 Silent Knight I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:129 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 *FA)( (763) 391-5464 DESIGN: Model 5D505-APS analog addressable photoelectric type smoke detector with model SD505- 4AB and 5D505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 'IDC INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: LJstee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:149 Rev. 05-27-2004 This Rating is based upon technical data submitted by the applicant CSFM Fire Engineering staff has revied the test results and/or other data but does not maim an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager a Model SD500-AIM Addressable Input Module And Model SD500-MIM Miniature Input Module lntelliKnight's addressable contact monitor modules combine fast response with pin-point location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's lntelliKnight fire control panels. The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. it Model SD500-AIM and SD500-MIM Input Modules The addressable input modules expand the flexibility of the lntelliKnight system by allowing the use of contact type inputs. Typical applications include manual pull stations and water flow switches. Features Operates on Class A (Style 6 & Style 7) or B (Style 4)SLC Loop. Single contact monitor. Up to 127 modules per SLC loop. SD500-MIM mounts in a single gang box. SD500-AIM mounts in a 4-square or double gang electrical box, and has an attractive ivory cover plate. SD500-AlM/MlM are DIP switch programmable. Accepts up to 14 gauge wire. Both modules UL 864 listed; comply with NFPA 72 2500 ft max. wiring distance from input module to contact. CSFM listed. MEA429-92-E, Vol. 9 FM approved Operation Each addressable input module is programmed with a unique SLC loop address. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. If a fault occurs in the wiring, the module alerts the FACP. D SILENT KNIGHT S flHoe)&I Compa!y Specifications Operating Voltage: 24 VDC Standby Current: 0.55 mA Alarm Current: 0.55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 5D500-AIM double gang box or 4-square electrical box SD500-MIM single gang box \) CAUTION REMOVE POWER PRIOR TO SERVICING 00 ____ '•- ------------- 7] SD500-AIM SD500-MIM Model SD500-AIM and SD500-MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model SD500-AIM 1 FRONT VIEW BACK VIEW SIDE VIEW CAUTION REMOVE POWER PRIOR TO SERVICING 93 4-718" ii Model SD500-MIM NMI Io I A - .. 2-1/2" Li 11/16" DSILENT KNIGHT N flflOfley,,O!I CO,,pa,y 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350231 Rev. B, 02/04 Copyright © 2004 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:132 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz (763) 493-6400 *FA)( (763) 391-5464 DESIGN: Models SD500-FRCM, SD500-FRCM4 Monitor Modules and Model 5D505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SD500-MIM Addressable Input Modules. Models SD500-FRCM and SD500-FRCM4 monitor modules provide Inputs fora control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models SD505-ARM and $0500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MlM provide additional input circuits. Refer to llstee's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM4, -ARM, -AIM, -MIM: 24 VDC SD505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and In a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to Iistee's installation Instruction Manual for details. XLF: 7300-0410:145 Rev. 05-27-2004 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not maki an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to lislee's data sheet Installation Instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 0 SD500-PS DSILENT KNIGHT SD500-PS and SD500-PSDA Addressable Pull-Station IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The InteIliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & SD500-PSDA Addressable Pull Station Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby current: .55mA Alarm Current: .55mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB The SD500-PS is a single action .addressable fire pull station, and the 5D500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) . • Surface mount back box available Terminals - accept up to 14 gauge wire Extremely easy to operate Corrosion-resistant gold-plated contacts. LC Mounting to Single Gang Electrical Box ~_ C]g - ~ Mounting to Option Surface Mount Box SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP R0 " t, Solid li~. qt~d li- return side --: N Wiring 3" 2-la" SD500-PSDA Z51 INJ!U t1 LTIJ'U [JJU UR!kb £ Q7""btmir 0 A LLAJ )O \c' Installing t)UULk EIe 21cI Dimensions D SILENT - KNIGHT - 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350342, Rev. 09/02 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright © 2002 Silent Knight Ll CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7150-0559:136 Page 1 of I CATEGORY: Boxes/Pull Stations USTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Fottz (763) 493-6400 'FAX (763) 391-5464 DESIGN: Model PS-SKSA and SD500-PS fire alarm pull boxes. Refer to hstee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: Ina rdance with Ustee's printed installation instructions, applicable codes & ordinances and In a manner acceptable to the authority having Jurisdiction. MARKING: Ustee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. S Rev. 05-284004 This listing Is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results andior other data but does not wake an Independent vwWmton ol any clexns. This Usting Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listao data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager L4MC'Strobe Models Available Strobes Red White S1224MC S1224MCW S1224MCP S1224MCPW S1224MCK S1224MCSP Horn/Strobes Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224M CSP Horns Red White H12/24 H12/24W H12/24K Product Overview Operates on either 12V or 24V Widest range of candela options: 12V: 15 and 15/75 candela 24V: 15, 15/75, 30, 75, 110 candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClickTM Synchronizable with MDL Sync.CircuitTM module Meets UL1971, NFPA72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. .®cQ LISTED CS549V602N917954 S5512 CS549V702N913751 S4011 MEA approved 7125-1209:222 APP-ED 122-02-E 7135-1209:223 3014150 126-02-E SpectrAlert® Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fea- tures that include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall feature set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" x 11/2" back box or a single gang 2" x 4" x lI" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. 49 The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and shall be approved for Synchronization Module Module shall be a System Sensor Sync'Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16" X 411/16" x 21/8" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. S Specifications Weight, strobe and horn/strobe Voltages 8.8 oz. 12 or 24VDC and FWR unfiltered Walk Test SpectrAlert horn/strobe and horn only work on "walk tests" with time dura- tions of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 5/" x 215/16" Strobe and horn/strobe with small footprint plate 3 /8" x 5/8" x 2/16" Horn with universal mounting plate 5" x 5/" x 1/16" Horn without mounting plate 215/16" x 5/16" x 1/16" Weight, horn only 7.2 oz. Mounting 4" x 4" x 1/" or 2" x 4" x 1/8" standard boxes Indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Maximum humidity 95% as tested per UL464 Operating Temperature Weatherproof (horn and horn/strobes) 32°F to 150°F (0°C to 66°C) (outdoor strobe only) —400+90F to +1510+90F (-400±50C to +66°±50C) ULC Canadian Models —40°C to 66°C Operating voltage range* 12V: 8-17.5V; 24V: 16-33V Operating voltage range* (with Sync.Circuit module, MDL) 12V: 9-17.5V; 24V: 17-33V *Note for Strobes: Do not exceed; 1) 16-33 or 8-17.5 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MDL Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line impedance as required by the fire alarm control manufacturer U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 I Permissible Candela Settings Candela Operating Voltage Setting 12V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK Viewing V 0. SpectrAlert Current Draw Series Candela Setting FWR Operating Current-Strobe (mA RMS) DC Operating Current- Strobe (mA RMS) FWR Operating Current-Horn (mA RMS) DC Operating Current-Horn (mA RMS) Horn Audibility (dBA) 12V 24V 12V 24V 12V 24V 12V 24V S1224MC 15 112 64 127 59 Strobes 15/75 135 74 127 69 30 93 90 75 158 160 110 208 209 P1224MC 15 112 64 127 59 45.7 57.5 44.4 57 75 Horn/Strobes 15/75 135 74 127 69 45.7 57.5 44.4 57 75 30 93 90 57.5 57 75 75 158 160 57.5 57 75 110 208 209 57.5 57 75 H12/24 Horns 45.7 57.5 44.4 57 75 V SpectrAlert Mounting and Operation Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the Temporal Low Volume rear of the product while watching the viewing window on the side of the reflector. High Volume Non-Temporal I Low Volume High Volume DIP Switch Operation Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Factory OFF ON Default DIP Switch Low High I Temporal I Non-Temporal I I Electromech. •I 300014z (j Base (rear) AOIIO-OO A0133-OO Typical weatherproof mounting with universal plate 01...*. 0 A01 20-0 For Plate Gasket SpectrAlert Ordering Information Model Description P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, weatherproof P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, FUEGO" housing 51224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt, white S1224MCP Selectable Output Strobe, 12/24 volt, red, plain housing S1224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing S1224MCK Selectable Output Strobe, 12/24 volt, red, weatherproof S1224MCSP Selectable Output Strobe, 12/24 volt, red, "FUEGO" housing Notes Model Description H12/24 Horn, 12/24 volt, red H12/24W - Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red, weatherproof Accessories MDL Sync.Circuit Module, red MDLW Sync.Circuit Module, white MDLA Sync.Circuit Module, red, Canadian model MDLWA Sync.Circuit Module, white, Canadian model S-MP Small Footprint Mounting Plate, red, for single- gang back box S-MPW Small Footprint Mounting Plate, white, for single- gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box Agency Listings - Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products are designed for wall mount only. All weatherproof models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. 40 System Sensor Sales and Service System Sensor Headquarters System Sensor Canada 3825 Ohio Avenue Ph: 905.812.0767 St. Charles, IL 60174 Fx: 905.812.0771 Ph: 800/SENSOR2 System Sensor Europe Fx: 630/377-6495 Ph: 44.1403.891920 www.systemsensor.com Fx: 44.1403.891921 System Sensor in China System Sensor - Far East Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 System Sensor in Singapore System Sensor - Australia Ph: 65.6273.2230 Ph: 613.54.281.142 En: 65.6273.2610 Fx: 613.54.281.172 System Sensor - India 16 Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0325-004.10/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7135-1653:163 Page 1 of I CATEGORY: Audible Devices LJSTEE: System Sensor, Unincorporated Div. of Honeywell int'l Inc 3825 Ohio Avenue, St Charles IL 60174 Contact Irish Unhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models P1224MC, P1224MCW, P1224MCSP, P1224MCSPW, P1224MCP, PI224MCPW, PI224MCK, and PI224MCWK combination horn/strobes with selectable candela. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 8-33 VDC/FWR 12124 VDCJFWR Selectable :l5cd, 15175cd 24 VDC/FWR Selectable: 30cd, 75cd, 110cd INSTALLATION: in accordance with Iistee's printed Installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for field assembly. MARKING: Ustee's name, model number, rating, and UL label. APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing Impaired application. For wall mount and indoor use only. Models with suffix W are suitable for extended indoor operation temperatures 32 to 150° F (0 to 66°C) and have NEMA type 3R enclosure rating for outdoor use. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. NOTE: Formerly 7135-1209:223 06-20.05 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has revied the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 20, 2005 Listing Expires June 30, 2006 Auttio,ized By: DIANE K. AREND, Senior Deputy Program Manager