Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 114; FPC2017-0210; Permitcity of PERMIT REPORT Carlsbad Print Date: 12/13/2021 Permit No; FPC2017-0210 Job Address: 2525 EL CAMINO REAL, # 114, CARI.SBAD, CA 92008-1206 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1563020900 Track #: Applied: 07/28/2017 Valuation: $1,253,304.97 Lot #: Issued: 08/14/2017 Occupancy Group: Project #: Finaled Close Out: 02/01/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: H&M -SPRINKLER TI >100 HEADS (276) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MATT JORGENSEN 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $634.00 Total Fees: $634.00 Total Payments To Date: $634.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fffC,2O[i-- 02- ~ (. 110 0 0 ...cosco Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscoflre.com MATERIAL SUBMITTAL Date: 7-28-17 M S OPPES AT CARLSBAD 2525 EL CAMINO REAL, SUITE 114 CARLSBAD, CA 92008 JOB # 10.CA_5358 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M. KELLER Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle Page 1 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT 4J II(IF4IG SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. S DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to 1/2 (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on', "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LI TINGSANDAPPROVALS Ut. us cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 Vds VdS Approved: Certificate G4080021 LPCB Approved: Ref. No. 096e/12 (( CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating 11250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending "cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 17.02.02 Rev 17.1 Replaces Form No. F_103005 Rev 16.1 (Added PNs for CCCF Approved sprinkler) Page 2 of 6 1%4 1 jU M MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-M, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135°F (57 °C) UL (139 °F (59 °C) FM and LPCB) =A, 165°F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2 ratchet (not available from Viking). ***optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 17.02.02 Rev 17.1 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. - I7i 1: AVAILABLE SPRINKLER T~MPERATIREE ~ROIN(~'X`Nfb FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Bulb Color Classification Temperature Rating' Ceiling Temperature' Assembly (Required) Ordinary 155 OF '68° C" / 100 OF 38 °c' ' ' 135 F (57 C) cULus 139 OF (59 °C) FM and LPCB Red Intermediate 175 OF (79 °C) 150 OF (65 °C) 165 OF (74 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) 165 OF (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction Refer to specific installation standards. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Approval Chart I (UL) , Mirage Concealed Pendent Sprinklers VK462 and VK463 Covet Ptale F,nsh KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Inch mm U.S. metric, cULus' NYC I VdS7 LPCB Base Part No.' Pressure Standard Response Applications 13503A VK462 1/2" - 5.6 80.6 175 psi (12 bar) -- -- AY1,CZI AYI,BZI AY1,CZ18 -- 19785A VK462 1/2" - 5.6 80.6 1 175 psi (12 bar) -- - - - -- AY2, CZ2 21356A VK462 - 15 5.6 80.6 175 psi (12 bar) -- - - - -- AY2, CZ2 Quick Response Application 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 - - -- -- 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 - - -- -- 13667A VK463 1/2" 15 5.6 80.6 1 250 psi (17.2 bar)' AV1, BX1 AV1, BW16 - - -- -- Cover Plate Assembly Temperature Ratings' Sprinkler Temperature Ratings V - 135 OF (57 °C) cULus Listed cover 135041, 136421 (large diam- Cover Plate Assembly Finishes18 A - ' 155 OF 68 °' eter), or 15394' (square cover plate) 1 - Polished Chrome, Brushed Chrome, Bright Brass, °C) W- 165°F (74 cover 135041 or 13642' (large diameter) Antique Brass, Brushed Brass, Brushed Copper, OF OF B- 175 (79 C) and 200 (93 C) X -165 °F (74 °C) cover 135041, or 136421 (large diameter) Painted White, Painted Ivory, or Painted Black C - 200 OF (93 C) Y - 135 OF (57 °C) cover 135041 LPCB Approved as 139 °F (59 °C) 2 - Brass Z - 165 OF (74 °C) cover 13504' Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. ° The 135/139 OF cover has an orange label. The 165 OF (74 °C) cover has a white label. 10 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No.F_103005 17.02.02 Rev 17.1 Page 4 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT 44J II(IF1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirages Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. S \\ \!IKW) All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Form No. F_103005 17.02.02 Rev 17.1 3-5116" (84 mm) Figure 2: Square Cover Assembly 15394 S S Page 5 of 6 MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT u SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart 2 (FM) Mirage'Standard Response Concealed Pendent Sprinkler VK462 WI+ Covet Pete Finish KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1 Cover Plate Assembly Temperature Ratings4 Cover Plate Assembly Finishes' Sprinkler Temperature Ratings w - 139 °F (59 "C) cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) or 153941 (square cover plate) Brass, Antique Brass, Brushed Brass, B - 175°F (79'C) and 200°F (93'C) X - 165°F (74 "C) cover 135041, 136421 (large diameter), or Brushed Copper, Painted White, Painted 153941 (square cover plate) Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139 °F (59 "C) cover has an orange label. The 165 °F (74 "C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (AJso refer to Approval Chart 2 above.) Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 17.02.02 Rev 17.1 2-1/4" (57 mm) diameter opening required in the ceiling. Page 6 of 6 MIRAGE® STANDARD AND QR CONCEALED PENDENT "4IiI SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page. Sprinkler Wrench : Part No. 14047W/B** —511 Step 1: Carefully slide the wrench sideways around the deflector and pins Step 2: t t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler and Adapter Assembly Protective cap removed Use wrench 14047 W/B** NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W1B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise Ito 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum / 2-1/16" (52 mm) ) Minimum : LO C4 Lo 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 17.02.02 Rev 17.1 Replaces Form No. F_103005 Rev 15.1 (Added PNs for CCCF Approved sprinklers; upgraded graphics) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applicationswhere colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 11 VdS Approved: Certificates G414009 and G414010 LPCB Approved (( CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-1/4" (58 mm) *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sorinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-IB, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.02.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) Page 2 of 6 l.l:II[.1i.uyy RESPONSE PENDENT - MICROFAST®QUICK SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY . The Viking Microfast' Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler ,i.Wrench Flat Clip \ 1 Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 17.02.02 Rev 17.1 Page 3 of 6 \ flflfl/7flr MICROFAST@ QUICK - \ k'(• IIH TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE - 'RATINGS AND FINISHES I Sprinkler Temperature Sprinkler Nominal Maximum Ambient B lb Color u Classification Temperature Rating' Ceiling Temperature' Ordinary 135°F(57°C) 100 °F(38°C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 OF (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of theAuthority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 112" ratchet is require (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers W"7711511 Form No. F_033314 17.02.02 Rev 17.1 Page 4 of 6 NIMM4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) - The Viking Microfast8 Quick Response TemperWum KEY Pendent Sprinkler VK302 A& E$JtthS jfeppitcab) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN Style K-Factor Length (Refer also to Design Criteria.)___________ Number' NPT BSP U.S. metric2 Inches mm cULus' VdS LPCB (E 12979 VK302 Pendent 1/2" 15 mm 56 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, BIY D1Z, dY -- -- 19780 VK302 Pendent 1/2" -- 56 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 -- -- - -- -- D3 06662B V1<302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- 18021 VK302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 AiX, B1Y Al AiX, B1Y Dlx, CIY8 DIX, CIY9 -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 "C) Polyester66, Black Polyes- Viking MicromatiO Model E-I Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter56 Y - Standard surface-mounted escutcheon or the (79 "C), and 200 OF (93 "C) 2 - ENT5 Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C -155 OF (68 °C), 175 OF (79 °C), and 3-Chrome matic6 Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the D - 155 OF (68 "C), 175 OF (79 "C), 200 OF Viking Microfast Model F-i Adjustable Escutcheon (93 °C), 286°F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1 008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The 'liking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules Contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. - [1 Form No. F_033314 17.02.02 Rev 17.1 Page 5 of 6 flflflfl MICROFAST® QUICK I i.]:ii[.L'Iu'7..w. RESPONSE PENDENT ri LI 'J SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) rTemPerure KEY The Viking Microfasf Quick Response *— Finis! Pendent Sprinkler VK302 MX4—Ecutthecaie) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metri0 Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF Viking Micromatic Model E-1 Recessed (93 "C), 286 OF (141 °C) Approved Finishes Escutcheon B- 135 OF (57 "C), 155 OF (68 "C), 175 OF (79 °C), and I -Brass, Chrome, White Polyester4, Y - Standard surface-mounted escutcheon or the 200 OF (93 "C) and Black Polyester4 Viking Microfast® Model F-I Adjustable Escutcheon, C - 155 OF (68 "C), 175 OF (79 "C), 200 OF (93 "C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 OF (141 "C) or E-2 Recessed Escutcheon D - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-I Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. P71-114 Form No. F033314 17.02.02 Rev 17.1 S Page 6 of 6 MICROFAST® QUICK "1 1KJNG4 lI.II[sflUI1If - SPRINKLER VK302 RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT\ 4.. (54 281___ (57 mm) (45 5 mm (51 mm) (38 mm) Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon L Ceiling Opening Size: 1 2-5/16" (59 mm) minimum "1 2-1/2" (64 mm) maximum 2-1/8" - -2-118"— (54 mm) Vf 21119 EJ(2 11 (45) 9mm) (51 mm) Max. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.02.02 Rev 17.1 Replaces Form No. F_033314 Rev 16.4 (Added PN for CCCF approved sprinkler.) Page 1 of nnn 1q ry ® MICROFAST® QUICK \W (n RESPONSE UPRIGHT ti \J LI 'J SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 "C) Overall Length: 2-3/16" (56 mm) "cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http:/Iwww.vikinggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape Screw: Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 "C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 Rev 15.2 Page 2 of 4 "\J MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The 'liking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLERTEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient C Bulb for U 0 Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 oF (57 °C) 100 ¶ (38 °C) Orange Ordinary 155 ¶ (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 C) 150 °F (65 °C) Green High 286 °F (141 C) 225 °F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat S Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_052114 Rev 15.2 Page 3 of 4 .-'--.------°-.'. nr7fl ' MICROFAST®QUICK lil:IIEU'JM.. RESPONSE UPRIGHT 1 \rJ SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart I (UL) -Tit iy I Microfasf Quick Response (wpprAfX cthi Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size I Nominal K-Factor I Overall Length Listings and Approvals3 Number' SIN I I I I NPT I BSP I U.S. I metric2 I I Inches i I mm I I cULus I VdS I LPCB I NYC8 12978 i VK300 1/2" 15 mm I 5.6 80.6 2-3/16 56 I Al, B2 I -- -- See footnote 7.1 -- 06661B I VK300 I 1/2" I 15 mm I 5.6 I 80.6 I 2-3/16 56 I Al, B2 I -- I -- Isee footnote 7.1 -- Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155 °F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) - Brass, Chrome, White Polyester56, and Black Polyester56 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metdc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 8 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA -_LJL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfasta Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 15.2 Page 4 of 4 NIMM4 MICROFAST® QUICK SPRINKLER VK300 (K5.6) RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) TemPemturO KEY FhM Mlcrofast® Quick Response A p4) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 06661 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Finishes Approved Temperature Ratings 1 -Brass, Chrome, White Polyester', and Black A- 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT Footnotes 1 Base part number is shown. For complete. part number, refer to Viking's current price schedule. 2Methc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - _FM (Also refer to Approval Chart 2 above.) FM Anoroval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 15.2 AIR Fully Listed and FM Approved Sprinkler Pipe III EM IRWIN III--- ,r '.t ', -.. ...'.- ..-,,..,.'... r-. .. r'-' ..V, Vy•'r ', '. When you specify Allied Schedule-11 O/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10fSchedule-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (ih/4"_ 8") pipe and Sch-40 (1"- 21/z") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. > Galvanized Pipe Schedule-i 0/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFll". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. > Specifications & Approvals Schedule-10/Schedule-40 -ABFII pipe are in compliance with the following: ASTM A-i 35, Type [Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture * See ABFII warranty NIPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 1.049 1.680 2.05 1 25 26.6 2.5 3.05 - 11/4 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 11/2 1.610 2.720 3.61 1 40 40.9 4.0 5.37 - 2.067 3.650 5.13 1 50 52.5 5.4 7.63 - 21/2" 2.469 5.790 7.86 1 65 62.7 8.6 11.73 - WN 01 NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; rnrn In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 11/4 1.442 1.810 2.525 7.0955 32 36.6 2.7 3.75 - 11/2 2.080 3.04 5.6570 40 42.7 3.1 4.52 - 2.157 2.640 - 4.22 4.5827 50 54.8 3.9 6,28 - 21/2" 2.635 3.530 5.89 - 3.5196 65 66.9 5.3 8.77 - 3.260 4.330 7.94 2.5550 75 - - 82.8 6.4 11.82 - 4.260 - 5.610 11.78 - 1.6020 100 108.2 8.3 17.53 - 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6.357 9.290 - 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 1 209.5 24.5 59.75 - APPROVED ci Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com "c7' Cl • 16100 S Lathrop Ave. • 11350 Narcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT* Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1105 C.I. THREADED FITTINGS FITTINGS rq.A Divhdon ofStarflpo Pmducu <~> 3 LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME 1316.14. THREADS ARE NPT PER ANSI/ASME 131.20.1. NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WBGIff - A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 1 2.25 2.25 2.90 21/2 CB90077 300 1 2.70 2.70 4.75 El NOMINAL SIZE (INCH) - ITEM CODE MAX. WORKING P.S.I. DIMENSION WHGHT EACH PIECE A 1X1/2 CRC031 300 1.70 0.62 1 X3/4 CRC032 300 1.70 0.80 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. WBGHT EACH PIECE DIMENSIO M - A 1X1/2 CB90031 300 1.26 1.36 0.64 1 X31 CB90032 300 1.37 1.45 0.87 I 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 112x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 112X1 114 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 1 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 38 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE - A - B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 2.51 2 CT666 300 225 2.25 3.96 2 1/2 CT777 300 2.70 270 6.45 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WGHT EACH PIECE - A - B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 1 CB450551 300 1.43 1 1.43 1.80 2 1 CB450661 300 1.68 1 1.68 2.79 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 NOMINAL SIZE (INCH) ITEM CODE _ ______ MAX. WORKING P.S.I. DIM B4SIONS WEIGHT EACH PIECE A B C 1 X1X1/2 CT331 300 1.26 1.26 1.36 0.95 I XI X3/4 C7332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1 X314X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/411 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 114 0T434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 1I2X1X1/2 C 53 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 32 300 1.52 1.37 1.75 1.65 1 1/2X1X1 33 300 1.65 1.50 1.80 1.65 1 1I2X1X1 114 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 35 ICT534 300 1.94 1.80 1.942.30 1 1/2X1 1/4X1/2 41 300 1.58 1 1.41 1.34 1.66 112X1 1/4X3/4 42 300 1.72 1 1.52 1.45 1.75 1/2X1 1/4X1 43 300 1.65 1.58 1.80 1.85 1 1/2x1 1/40 IN CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 IN 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 C1553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1 X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 1 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 CT667 1 300 2.60 2.60 1 2.39 1 5.10 U C.I. THREADED FITTINGS ,6 FITTINGS A Diiio ofShrPipc * (~~ <t~> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WOGHT EACH PIECE - A - B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 1112 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 202 2.75 A Page 39 . Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-Ta Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. - JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date www.victaulic.com vrcTAuLlc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2150 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Dimensions J1t * 2 ½ (a) 920N 500 1.50 2.00 2.53 1.61 5.35 2.751 3.1 50 15 3450 38.1 51 64 - 41 136 70 1.5 - 3/4 (a) U 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) a 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 1 1/4 (a) to 920N 500 I. 2.05 2.75 3,00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) to 2 N 9 0 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2½ x 1/2 (a) § a 920N 500 1.50 2.21 2.74 91.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 ' 46 143 70 1.4 - 1/4 (a) §0920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §0 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38,1 52 70 - 46 143 70 1,4 - 1 1A t (a) a 920N 500 1.75 2.30 3.00 3.25 1,82 6.29 3.00 3.5 3.2 32 3450 44.5 1 58 76 83 46 160 76 1,7 1.5 1 ½ t (a) a 920N 500 2.00 2.28 3.00 3.25 1,82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 761 x ½ (a) 920N 300 1.50 2.22 2.75 2.25 6,46 3,18 3.9 15 2065 38.1 56 70 - 57 164 81 1,8 - 1/4 (a) 920N 300 1.50 2,19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 57 164 81 1,8 - 1(a) 920N 300 1,50 2.07 2.75 - 2.25 6,46 3,18 3.8 - 25 2065 38.1 53 70 57 164 81 1.7 1¼ (a) 13 920N 500 1.75 2.30 3.00 3,31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 - 1.5 1 ½ (a) 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 x 1/2 (a) a 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38,1 64 78 - 58 156 70 1.6 - 1/4 (a) D 920N 500 1.50 2,49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1,6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1,6 - 1 1/4 (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) to 92019 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40 (b( 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 x 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 63.5 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order, * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com \,/taUIice vlcTAuuc IS REGISTERED TRADEMARK OF VIcTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET .• Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 . Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size ___________No. Style _____________ Max. Work Dimensions Appr x. Weight ___________ TABLE CONTINUED FROM PAGE 2 4 x ½ (a) a 920N 500 1.50 1 3.03 1 3.56 I 2.69 7.01 2.75 - 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 - '/4 (a) D 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 J 3450 38.1 76 90 - 68 178 70 1.8 1(a) a 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1 ¼ (a) to 920N 500 32(b) 3450 44.5 Th 96 102 68 178 76 1.9 1.8 1 1h (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 10 1.9 2 (a) ta 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 21/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 29 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 1 196 1 130 3.8 19 1 ¼ (a)a 108.0 x 500 1.75 96 3.08 3.78 2.63 7.64 3.05 5.0 32 0N 3450 44.5 78 - 67 194 78 23 1 ½ (a)a 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 2.3 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 - 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 35 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1 1/2 (a) t 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 -3450 63.5 102 121 121 80 246 - ill - 21/2 (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 38 3.6 76.1mma 920 500 2.75 3.75 4.75 3,16 9.70 4.63 8.0 3450 69.9 95 -121 80 246 118 16 3 (a) 1' 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 38 4.0 1330 < 2 ON 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 - 50 3450 63.5 95 114 - 81 203 99 3.6 3 920 500 3.50 3.81 5.00 3.00 9.46 5.31 1 8.0 - 80 3450 88.9 97 127 - 76 240 135 3.6 - TABLE CONTINUED Or PG.4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com \tauIic. VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 1103 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 'H/SO x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Dimensions MW&7~ S TABLE CONTINUED FROM PAGE 3 1 V2 t 139.7 >< 920N 500 2.00 1 3.78 1 4.50 3.30 8.23 3.25 7,0 40 3450 50.8 96 114 - 84 209 83 3.2 - 2t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 - 84 209 99 4.1 - 6 1 1/~ (a) 920N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 11/2 (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) to 2 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 7 6.1 mm 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 3(a) I' 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 11/2 (a) 159.0 x 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 1 83 3.5 - 2 lal 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 1080mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com Aic- VIcTAuLIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. taul i C CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 . Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET R\j., 1p ø44 4 J FEMALE THREADED OUTLET .• Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 4/200 x 100 mm Size Style N Max. Work P,essure@~ Dimensions MR ML am mm I TABLE CONTINUED FROM PAGE 4 - 1651 x 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 3.6 1 ¼ ° 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44 96 237 83 18 1 ½ (a) # 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3,25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 24 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 _ 3450 69.9 110 130 132 92 267 118 3.9 3-4 3 (a) t 0 920 500 3.50 4.31 5.50 5.13 3.63 10,51 5.31 10,2 8.4 80 3450 88.9 110 140. 130 92 267 135 4.6 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 1143 97 146 137 92 267 159 4.8 3.8 8 2(a) 1' 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 2½ (a) 1' 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm a 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11,6 _ 3450 69.9 133 159 122 316 1 116 5.3 3 (a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12,6 11,6 80 3450 88.9 135 165 165 122 316 135 5.7 _5.3_ 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15,3 12.5 100 3450 114.3 122 171 162 122 316 159 1 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 'f Available with grooved or female threaded outlet. Specify choice on order. $ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaUlic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Exaggerated for clarity Formulas for C,1(. Values: AP =Q2 Where: Q= Flow (GPM) v AP = Pressure Drop (psi) 0 = C x C = Flow Coefficient AP = Q2 Where: Q = Flow (m3/h) = Pressure Drop (bar) Q K x /AP l( = Flow Coefficient OUTLET SIZE t]1tI ' ) Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, Sec. 16) {e1:{,I'iI) iIzlt'1J Mrs M64 iliTi1i) ½ 0.840 11 15 21.3 2 - 9.4 3% 1.050 16 20 26.7 - - 13.7 1 1.315 21 - 8 25 337 - 1.8 1/4 1.660 50 48 32 42.7 5 '/2 6 42.9 41,1 1½ 1.900 11 1 53 53 40 98.3 1 45.4 45.4 2 2.375 112 104 50 60.3 9 1 10 /2 96 89.1 2½ 2.875 119 150 65 73.0 20 12½ 102 128.5 76.1 mm 3.000 16 - 161 - 76.1 138.1 3 3.500 249 237 80 88.9 14 15 1/2 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 1 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.1 65in14.2mm. www.victaulic.com j41ftauIic vlcrAuuc IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. 0 2010 vicTAuLic COMPANY. ALL RIGHTS RESERVED. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size X? IL Outlet Size !I1 am Pipe Appro at Agency Rated Working 'Pressures - psi/kPa 6D am 21/2 - 6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2 - 4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2 -4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - 145 - 200 219.1 2755 - - 1000 8 8.625 3,4 10 300 250 - 145 - 200 219.1 2065 - 1724 1000 8 8.625 314 30,40 300 - 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 57125 mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAuLIc IS REGISTERED TRADEMARK OF vlClAuLlc COMPANY. 0 2010 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. 4tauijcr Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N 0 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are install:ng. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 ictaulia VICTAULIC IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. © 2010 VICTALJLIC COMPANY. ALL RIGHTS RESERVED. MINI-UNDERCUT+ THREAD VERSION UNCThread ANCHOR MATERIALS Zinc plated carbon steel ANCHOR SIZE RANGE (TYR) 3/8" SUITABLE BASE MATERIALS Post-Tension Concrete Precast Hollow-Core Plank Normal-weight concrete CODE L1STEJi1 ICC-ES_ESR-391 2 RflE GENERAL INFORMATION GENERAL INFORMATION MINI-UNDERCUT+M Internally Threaded Undercut Anchor The Mini-Undercut+ anchor is an internally threaded, self-undercutting anchor designed for performance in cracked and uncracked concrete. Suitable base materials include post-tension concrete (PT slabs), hollow-core precast concrete, normal-weight concrete, sand-lightweight concrete and concrete over steel deck. The Mini-IJndercut+ anchor is installed into a pre-drilled hole with a power tool and a setting tool. The result is an anchor which can provide consistent behavior at shallow embedments as low as 3/4 of an inch. After installation a steel element is threaded into the anchor body. SECTION CONTENTS General Information.........................1 Installation Instructions..................2 Reference Data (ASD)......................3 Strength Design (SD).......................4 Ordering Information.......................6 + Ideal for precast hollow-core plank and post-tensioned concrete slabs + Cracked concrete tested alternative to a mini dropin anchor + Redesigned ANSI carbide stop bit with enlarged shoulder for accurate depth + Anchor design allows for shallow embedment as low as 3/4 of an inch + Internally threaded anchor for easy adjustment and removability of threaded rod or bolt + Drill and drive the anchor with one tool for fast anchor installation International Code Council, Evaluation Service CC-ES), ESR-391 2 for Concrete and Hollow-Core precast slabs, Code Compliant with the 2015, IBC, 2015 IRC, 2012 IBC, 2012 IRC, 2009 IBC, and 2009 IRC, Qualified according to ACI 355.2 (including ASTM E 488) for use in concrete FM Approvals (Factory Mutual) - File No. J.I. 3059197 CSI Divisions: 03 16 00 - Concrete Anchoring and 05 05 19 - Post Installed Concrete Anchors. Expansion anchors shall be Mini-Undercut+ as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instructions and the Authority Having Jurisdiction. Tension zones, seismic and • Fire Sprinkler & pipe supports wind loading applications • Cable Trays and Strut Suspended Conduit • Suspended Lighting 0 1 www.0EWALT.com INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS the required stop drill bit drill a hole into . Using t' the base material to the / required depth using . the shoulder of the drill bit as a guide. The tolerances of the drill bit used must meet the I I requirements of ANSI Standard B212.15. Remove dust and -, ... • . Attach the required debris from hole ' '.' '. '• SOS setting tool (e.g. suction, to the hammer- forced air) remove drill. Mount the loose particles left 2.• • open end Of the from drilling, anchor onto the setting tool. Drive the anchor into the hole until the shoulder of the anchor is flush with . ... the base material. Insert threaded rod or bolt full depth ,., into the : • Mini-Undercut+, taking care not to exceed the maximum tightening torque of the steel insert element, T. Installation Information for Minl-Undercut+ Anchor123 ii Anchor DIameter (Inch) Anchor Property/Setting Infoimatlon Symbol Units 3/8 Anchor outside diameter d2 in. 0.625 (mm) (15.9) Internal thread diameter (UNC) d in. (mm) 3/8 (9.5) Nominal drill bit diameter dun in. 5/8 (mm) ANSI Minimum nominal embedment depth hm in. 3/4 (mm) (19) Effective embedment depth het in. (mm) 3/4 (19) Hole depth h0 in, 3/4 (mm) (19) Overall anchor length Pefore setting) earch in. (mm) 15/16 . (24) Approximate tool impact power (hammer-drill) - J 2.1 to 2.8 Minimum diameter of hole clearance in fixture for dh in. 7/16 steel _insert _element _(following _anchor _installation) Minimum member thickness in normal-weight hmi in. 2-1/2 concrete (mm) (64) Minimum cover thickness in hollow core concrete hmin. in. 1-1/2 slabs (see Hollow-Core concrete figure) . (mm) (38) Critical in. edge distance cac 2-1/4tical (mm) (57) Minimum edge distance Cm2 in. 2-1/2 (mm) (64) Minimum spacing distance Smin in. 2-3/4 (mm) (70) Maximum installation torque Tmax ft.-lb. 5 (Nm) (7) Effective tensile stress area A. in .2 0.044 (undercut anchor body) (mm2) (28.4) Minimum specified ultimate strength futa psi (N/mm2) 95,000 (655) Minimum specified yield strength fya psi (N/mm2) 76,000 (524) Mean axial stiffness2 Uncracked concrete lbf/in. 50,400 Cracked concrete lbf/in. 29,120 For SI: 1 inch = 25.4 mm, 1 ft-lbf = 1.356 N-m. The information presented in this table is to be used in conjunction with the design criteria of ACI 318-14 Chapter 17 or ACI 318-11 Appendix D, as applicable. For installation detail for anchors in hollow-core concrete slabs, see Hollow-Core concrete figure. The embedment depth, hm, is measured from The outside surface of the concrete member to the embedded end of the anchor. Mean values shown, actual stiffness varies considerably depending on concrete strength, loading and geometry of application. Li WwW.DEWALT.com 2 STOP DRILL BIT MINI-UNDERCUT+ SElliNG TOOL REFERENCE DATA (ASD) I T I-r-. I .,., : I. d00 . A : k c - ooeh 4 :1 C 1 A V- •4 d1, .' >.f. ea'h • h, 4 h I' II P. • * II l .A d. Before After Mini-Undercut+ Anchor Installed with Steel Insert Element , •4 .., d. Do not exceed Donotnoceed (y REFERENCE DATA (ASD) Ultimate and Allowable Tension Load Capacities for Mini-Undercut+ In Normal-Weight Concretet-0 Minimum Concrete Compressive Strength NonaI 11111nimurn Rod/ Nondnall to = 3,000 psi (20.7 tiWa) ft = 4,000 psi (27.6 MPa) Ultimate DJlowable Ultimate Allowable Anchor E. 011arneter Depth Tension Shear Tension Shear Tension Shear Tension Shear d In. In. (mm) lbs lbs lbs We the the lbs lbs (ku) (kul) (kti) NO (kul) 3/4 1,535 1,975 385 495 1,770 2,275 445 570 / 38 (19) (6.8) (8.8) (1.7) (2,2) (7.9) (10.1) (2.0) (2.5) 1 Tabulated load values are for anchors installed in concrete. Concrete compressive strength must be at the specified minimum at the time of installation. Allowable load capacities are calculated using an applied safety factor 4.0. Linear interpolation may be used to determine allowable loads for intermediate compressive strengths. Ultimate and Allowable Tension Load Capacities for Mini-Undercut+ In Hollow-Core Plank 1,2,3 () Minimum Concrete Compressive Strength Noinal 1111inknurn Rod/ Hooded fc = 5,000 psi (34.5 l,a) t'c = 6,000 PSI (41.4 MIte) f'c = 8,000 psi (55.2 We) ijmmate Allowable Ultimate Allowable Ultimate Allowable Anchor Enthed. Diarneter Depth Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear d In. In. (mm) lbs lbs lbs the lbs the lbs lbs lbs lbs lbs lbs (M) No (MI) (Ml) (MI) (Ml) (Ml) (Ml) Will No (MI) (MI) 8 3/4 1,855 2,590 465 650 2,035 2,835 510 710 2,345 3,275 585 820 (19) (8.3) (11.5) (2.1) (2.9) (9.1) (12.6) (2.3) (3.2) (10.4) (14.6) (2.6) (3.6) Tabulated load values are for anchors installed in concrete. Concrete compressive strength must be at the specified minimum at the time of installation. Allowable load capachies are calculated using an applied safety factor 4.0. Linear interpolation may be used to determine allowable loads for intermediate compressive strengths. Mini-Undercut+ Installed Detail for Anchor in the Underside of Hollow-Core Concrete slabs 10 3 wWW.DEWALT.com STRENGTH DESIGN (SD) STRENGTH DESIGN Tension Design Information for Mini-Undercut+ Anchors in the Underside of CODE lASTED Normal-weight Concrete and the Underside of Hollow-Core Concrete Slabs, 2,3,4,5,6,7 ICC-ES ESR-3912 Hon" Anchor Size I Threaded Rod Diameter (inch) Design Characteristic; tlotallon Units 318 Anchor category 12 013 - 1 Nominal embedment depth h Steel Strength In Tension (ACI 318-14 17.4.1 or ACI 318-11 D.5.1) Steel strength in tension Nm lb 4,180 Reduction factor for steel strength çb - 0.65 Concrete Breakout Strength In Tension (ACI 318-14 17.4.2 or ACI 318-11 0.5.2) Effective embedment hei in. (mm) 3/4 Effectiveness factor for uncracked concrete kLm& - 24 Effectiveness factor for cracked concrete ka 17 Modification factor for cracked and ••PN - 1.0 (see note 5) uncracked concrete Critical edge distance Ld in. (mm) 2-1/4 (57) Reduction factor, concrete breakout strength' - 0.40 Pullout Strength In Tension (ACI 318-14 17.4.3 or ACI 318-11 0.5.3) Pullout strength, uncracked concrete Np,urcr lb J) See note 7 Pullout strength, cracked concrete Npp lb 455 Reduction factor, pullout strength - 0.40 Pullout Strength In Tension For Seismic Applications (ACI 318-14 17.2.3.3 or ACI 318-11 0.3.3.3) Characteristic pullout strength, seismic Np,w lb 410 (182) Reduction factor, pullout strength, seismic - 0.40 For SI: 1 inch = 25.4 mm, 1 ksi = 6.894 N/mm'; 1 Ibf = 0.0044 kN. The data in this table is intended to be used with the design provisions of ACI 318-14 Chapter 17 or ACI 318-11 Appendix D, as applicable; for anchors resisting seismic load combinations the additional requirements of ACI 318-14 17.2.3 or ACI 318-11 D.3.3, as applicable, shall apply. Installation must comply with manufacturer's published installation instructions and details. All values of 0 are applicable with the load combinations of IBC Section 1605.2, ACI 318-14 Section 5.3, or ACI 318-11 Section 9.2. The threaded rod or hot strength must also be checked, and the controlling value of Ow= between the anchor and rod must be used for design. Select the appropriate effectiveness factor for cracked concrete (k) or uncracked concrete () and use f/IN = 1.0. The characteristic pullout strength for concrete compressive strengths greater than 2,500 psi for anchors may be increased by multiplying the value in the table by (t'c / 2,500)1 for psi or (t'c /17.2)". For hollow-core concrete slabs the characteristic pullout strength for concrete compressive strengths greater than 6,000 psi for anchors may be increased by multiplying the value in the table by (f'c I 6,000)" for psi or )f'c / 41.4)". Reported values for characteristic pullout strength in tension for seismic applications are based on test results per ACI 355.2, Section 9.5. w.DEWALT.com Nominal Anchor Size I Threaded Rod Diameter (Jncli) Design Characteristic Notation Units 318 Anchor category 1 2 or 3 - 1 Nominal embedment depth hm Steel Strength In Shear (ACI 318-14 175.1 or ACI 318-110.6.1) Steel strength in shear 1 VO lb () 985 (44) Reduction factor, steel strength 0 1 - 0.60 Steel Strength In Shear for Seismic (ACI 318-14 172.3.3 or ACI 318-11 D.3.3.3) Steel strength in shear, seismic V, 1 lb 895 Reduction factor, steel strength in shear, seismic 0 - 0.60 Concrete Breakout Strength In Shear (ACI 318-1417.5.2 or ACI 318-11 D.6.2) Load bearing length of anchor in shear Nominal outside anchor diameter d8 in. 0.625 Reduction factor for concrete breakout strength 0 - 0.45 Pnyout Strength In Shear (ACI 318-14 17.5.3 or ACI 318-11 D.6.3) Coefficient for pryout strength km - 1.0 Effective embedment hei in. (mm) 3/4 (19) Reduction factor, pryout strength - 0,45 For SI: 1 inch = 25.4 mm, 1 lbf = 0.0044 kN. The data in this table is intended to be used with the design provisions of ACI 318-14 Chapter 17 or ACI 318-11 Appendix D, as applicable; for anchors resisting seismic load combinations the additional requirements of ACI 318-17 17.2.3 or ACI 318-11 D.3.3, as applicable shall apply Installation mast comply with manufacturer's published installation instructions and details. All values of 0 are applicable with the load combinations of IBC Section 1605.2, ACI 318-14 Section 5.3, or ACI 318-11 Section 9.2. The strengths shown in the table are for the Mini-Undercut+ anchors only. Design professional is responsible for checking threaded rod strength in tension, shear, and combined tension and shear, as applicable. Reported values for steel strength in shear are based on test results per ACI 355.2, Section 9.4 and must be used for design in lieu of the calculated resets using equation 17.5.1 .2b of ACI 318-14 or equation D-29 in ACI 318-11 D.6.1.2. Reported values for steel strength in shear for the Mini-Undercut+ anchors are for seismic applications and based on test results in accordance with ACI 355.2, Section 9.6 and must be used for design. I STRENGTH DESIGN (SD) Shear Design Information for Mini-Undercut+ Anchors in the Underside of CODE LISTED I Normal-weight Concrete and the Underside of Hollow-Core Concrete Slabs1'2345'6 ICC-ES ESR-3912 wWw.DEWALT.com ORDERING INFORMATION Cat No. Anchor Size Rod/Anchor Dia. Drill Diameter Overall Length Box Qty. CM. Qty. PFM2111820 3/8 x 3/4' 3/8 5/8 3/4' 100 600 Cat. Do. 1lnl-Undercut+ Size Rod/Anchor Dia. I Drill I Diameter I Drill Depth Std. Pack I PPA2431720 5/8 x 3/4" Stop Drill Bit - PT Anchor 3/8 I 5/8 I" 1 1 CA W. Chill-!I+ Rod/Anchor Dia. I Still. I I PFM2101720 3/8 SDS+ Setting Tool - PT Anchor 3i'8° 1 Description I Anchor Cat lb. Accu CaL -Bir I SDSPIus Setting Tool I I Recommended SOS I I Cat NO. Hammer-Tools (DswAl.T) I I I 3/8 x 3/4' Mini-Underc+ PFM2111820 PPA2431 720 PFM2101720 I 0CH273, DCH1 33, 025133,025262 I 0 0 0 0 0 w.DEWALT.com 6 Fig. 2005 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by 1 37 It4rd Pipe Hangers ®T0 co4 USnO Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B311ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. / For hanger with non-captured nut order Fig. 200S. / (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in ".. hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4 (20mm) thru 8 (200mm)). Fig. 200-1 to 202 Conforms to Federal Specifications \N\N-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel .- 1 • Designed to meet or exceed requirements of Fig. 200C - Fig. 200F Pipe Size Rod Size A B Approx. WtJ100 Part No. in. 1mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" - (15) /811-16 31I8 (79.4) 2/8" (66.7) - - 11 (5.0) . -. 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) - /8"-16 3/8" (85.7) 2/8" (66.7) 12 - (5.5) -: 200-11/4 11/4" (32) /e"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-11I2 11/2" (40) - - /8"-16 3/8" (98.4) - 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) I 200-21/2 21/2" (65) /8"-16 5/8' (142.9) - 41/8" (104.7) - 27 - (12.3) 200-3 3" (75) /o"-16 51/8" (149.1) 4" (101.6) 29 (13.3) 200-31I2 - 31/2" (90) /8"-16 7I8" (187.3) 51/4" (133.3) 34 (15.6) - 200-4 4" (100) /8"-16 - - - 7/8" (187.3) 5" (127.0) - 35 (16.0) 200-5 5" (125) 1/2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"_13 101/8' (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" - (200) 1/2"_13 131/8" (333.4) 8/4' (222.2) 136 (62.3) i Fig. 200 B A Fig. 200-1/2.200-3/4 Fig. 200-21/2 to 200-8 MR Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2" (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUl) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the f 3 product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre.-drilling of a pilot hole in wood is required. 111 Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size WtJ100 Part No. in. (mm) in. (mm) in. (mm) in. 1mm) Ft. (ml in. (mm) Lbs. (kg) 24-/4 3/4 (20) 2/16 (587) 1/32 (278) 1/16 (302) 51/2 (167) /16 (79) 9 (41) 24-1 1' (25) 2/8' (66.7) 1/16' (33.3) 1/16" (30.2) 6 (1.83) /16' (7.9) 9 (4.1) 2411/4 1'I4' (32) 3" (76.2) 1112' (38.1) 1/16" (30.2) 61/2 (1.98) - 5/" (7.9) 11 (5.0) - 24-11/2 11/2' (40) 31/4' (82.5) 1/8' (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 24-2 2" (50) 311/16' (93.7) 127/32 (43.6) 1/16" (30.2) 8 (2.44) - /16' (7.9) iS (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUI). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 B • All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in mil imeters unless otherwise specified. —Line by 38 Fire Protection Solutions A Thread Size All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions B-Line by T4 Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ØTOLcO B32051 - Threaded Rod (right & left hand threads) Size Range: I8'-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F 1399°Cl Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish fl Standard Design Load Thread Size Thread Length TL 650°F (343°C) 750°F (399°C) Part No. . A in, (mm) Lbs. (kN) Lbs. (kN) B3205-318x 1 /t"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-'/2x 1 '/2 -13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-518 X 1 21/2" (63.5) - 2160 (9.61) 1692 (7.52) B3205-3/4x /4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 x 1 /811-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog AIR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2"-6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended Load Approx. Wt./100 R. & Size Per Inch Lbs. (kN) Lbs. (kg) AIR 1/4" x'1' 20 240 (1.07) 12 (5.441 AIR /8" x '1' 16 730 (3.24) 29 (13.15) AIR 1/2" x '1' 13 1350 (6.00) 53 (24.04) AIR /8" x 'L' 11 2160 (9.60) 89 (40.37) AIR 3/4" x '1' 10 3230 (14.37) - 123 (55.79) AIR 7/6" x '1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. 11