Loading...
HomeMy WebLinkAbout2548 CAMPBELL PL; ; AS060259; PermitCity of Carlsbad Sprinkler Permit Permit No: AS060259 Job Address: 2548 CAMPBELL PL Status: ISSUED Permit Type: SPRINK Applied 11/2/2006 Parcel No: 2132610700 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: BRESSI RANCH LOT 16 FIRE SPRINKLER INSPECTIONS Applicant: INDUSTRIAL FIRE SPRINKLER CO., 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 Owner: RED TEXAS REALTY L L C C/O ST. CROIX CAPITAL CORP 4350 EXECUTIVE DR #301 SAN DIEGO CA Fees ($) I Add'I Fees ($) Total ($) Balance ($) 372 0 372 0 - - - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 16 Building : BUILDING A Location : 2548 CAMPBELL PLACE System REMOTE AREAI Contract Data File : Bressi-2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N. H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 16 Date 9/5/06 Hydraulic Desian Information Sheet Name - BRESSI RANCH LOT 16 Date - 9/5/06 Location - 2548 CAMPBELL PLACE Building - BUILDING A System No. - REMOTE AREA1 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - Calculated By - M.G. Drawing No. - FP-2 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 14'-2" Occupancy - ORDINARY GROUP 2 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (X) Wet Make GLOBE D Area Per Sprinkler - 123 MAX. ( ) Dry Model GL E Elevation at Highest Outlet - 13'-2" ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9/5/06 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 90 @ Press - R Residual Press - 88 Elev. - Well Flow - 1272 Proof Flow S Elevation - 323.0 U P Location - CAMPBELL PLACE P L Source of Information - PERFORMED BY I.F.S., WITNESSED BY CARLSBAD WATER DIST Y Commodity Class Location Storage Mt. Area Aisle W. Storage Method: Solid Piled % Palletized % Rack Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non Mult. Row ( ) Open Shelf Flue Spacing Clearance:Storage to Ceiling Longitudinal Transverse Horizontal Barriers Provided: C 0 M M SR TA O C R K A G E Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 16 Date 9/5/06 City Water Supply: Demand: Cl - Static Pressure : 90 DI - Elevation : 12.850 C2 - Residual Pressure: 88 D2 - System Flow : 435.536 stem Pressure : 79.986 C2 - Residual Flow : 1272 D2 - SrDeman HoseAdj City) ______ Hose d) : 250 D3 - System Demand : 685.536 Safety Margin : 9.376 150 140 130 P 120 R° 100 - C2 C90 - 02 S 80 u70 D3 R6° E5° 40 30 20 10 --Dl- I I I I S 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 16 ------------------------------- Date 9/5/06 Fitting Legend Abbrev. Name ½ % 1 1¼ 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow ThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 16 Date 9/5/06 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. SOOI 13.17 5.6 19.53 na 24.75 0.2 116.2 7.0 S002 13.17 5.6 19.21 na 24.54 0.2 116.2 7.0 S003 13.17 5.6 20.05 na 25.07 0.2 116.2 7.0 S004 13.17 5.6 21.84 na 26.17 0.2 116.2 7.0 S005 13.17 5.6 24.98 na 27.99 0.2 116.2 7.0 S006 . 13.17 5.6 19.62 na 24.8 0.2 123 7.0 S007 13.17 5.6 19.3 na 24.6 0.2 123 7.0 S008 13.17 5.6 20.14 na 25.13 0.2 123 7.0 S009 13.17 5.6 21.94 na 26.23 0.2 116.2 7.0 SOlO 13.17 5.6 25.1 na 28.06 0.2 116.2 7.0 SOIl 13.17 5.6 32.63 na 31.99 0.2 116.2 7.0 S012 13.17 5.6 32.11 na 31.73 0.2 116.2 7.0 S013 13.17 5.6 33.47 na 32.4 0.2 116.2 7.0 S014 13.17 5.6 23.78 na 27.31 0.2 123 7.0 S015 13.17 5.6 23.4 na 27.09 0.2 123 7.0 S016 13.17 5.6 24.41 na 27.67 0.2 123 7.0 18 13.17 20.02 na 19 13.17 20.27 na 20 13.17 21.15 na 21 13.17 23.04 na 22 13.17 26.34 na 7A 13.17 36.73 na 15 13.17 33.27 na 16 13.17 33.67 na 17 13.17 35.08 na 10 13.17 24.27 na 11 13.17 24.56 na 12 13.17 25.62 na 9A 13.17 39.91 na 1 13.17 19.93 na 2 13.17 20.17 na 3 13.17 21.05 na 4 13.17 22.93 na 5 13.17 26.22 na 6A 13.17 36.56 na 6 11.0 . 42.3 na 7 11.0 42.49 na 8A 11.0 43.1 na 9 11.0 43.15 na 138 25.5 43.61 na 137 25.5 43.54 na 136 25.5 43.46 na 126 25.5 43.79 na 122 25.5 43.69 na 121 25.5 43.5 na 101 25.5 43.83 na 121A 25.5 43.3 na 116 25.5 43.63 na 117 25.0 51.82 na 118 25.0 51.84 na 119 25.0 51.91 na 120 25.0 52.64 na 180 25.5 39.83 na 181 11.0 44.31 na 8 11.0 43.83 na 111 25.0 52.25 na 112 25.0 52.29 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Plow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 16 Date 9/5/06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea 113 25.0 52.39 na 114 25.0 52.49 na 115 25.0 53.1 na TRA 25.0 54.01 na Fl 11.0 60.47 na BRA 1.0 66.98 na A -3.0 68.84 na BF2 -3.0 69.55 na BFI -3.0 73.07 na B -3.0 73.42 na 250.0 D -3.0 73.45 na E -3.0 73.7 na TEST -16.5 79.99 na The maximum velocity is 20.3 and it occurs in the pipe between nodes 22 and 7A Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 5001 24.75 1.049 1E 2.0 0.080 19.526 K Factor = 5.60 to 120 0.0 2.000 0.0 1 24.75 0.1933 0.0 2.080 0.402 Vet = 9.19 0.0 24.75 19.928 K Factor = 5.54 S002 24.54 1.049 IT 5.0 0.080 19.208 K Factor = 5.60 to 120 0.0 5.000 0.0 2 24.54 0.1900 0.0 5.080 0.965 Vel= 9.11 0.0 24.54 20.173 KFactor= 5.46 S003 25.07 1.049 IT 5.0 0.080 20.047 K Factor = 5.60 to 120 0.0 5.000 0.0 3 25.07 0.1978 0.0 5.080 1.005 Vet = 9.31 0.0 25.07 21.052 KFactor= 5.46 S004 26.17 1.049 IT 5.0 0.080 21.844 K Factor= 5.60 to 120 0:0 5.000 0.0 4 26.17 0.2142 0.0 5.080 1.088 Vet = 9.71 0.0 26.17 22.932 K Factor = 5.46 S005 27.99 1.049 iT 5.0 0.080 24.985 K Factor = 5.60 to 120 0.0 5.000 0.0 5 27.99 0.2423 0.0 5.080 1.231 Vet = 10.39 0.0 27.99 26.216 KFactor= 5.47 S006 24.80 1.049 1E 2.0 0.080 19.617 K Factor = 5.60 to 120 0.0 2.000 0.0 18 24.8 0.1938 0.0 2.080 0.403 Vet = 9.21 0.0 24.80 20.020 K Factor= 5.54 S007 24.60 1.049 1 5.0 0.080 19.297 K Factor = 5.60 to 120 0.0 5.000 0.0 19 24.6 0.1909 0.0 5.080 0.970 Vet = 9.13 0.0 24.60 20.267 K Factor= 5.46 S008 25.13 1.049 IT 5.0 0.080 20.140 K Factor = 5.60 to 120 0.0 5.000 0.0 20 25.13 0.1986 0.0 5.080 1.009 Vet= 9.33 0.0 25.13 21.149 KFactor= 5.46 S009 26.23 1.049 IT 5.0 0.080 21.945 K Factor= 5.60 to 120 0.0 5.000 0.0 21 26.23 0.2150 0.0 5.080 1.092 Vel = 9.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 26.23 23.037 K Factor= 5.46 Solo 28.06 1.049 IT 5.0 0.080 25.099 K Factor = 5.60 to 120 0.0 5.000 0.0 22 28.06 0.2433 0.0 5.080 1.236 Vel = 10.42 0.0 28.06 26.335 K Factor= 5.47 SOIl 31.99 1.049 1 2.0 0.080 32.626 K Factor = 5.60 to 120 0.0 2.000 0.0 15 31.99 0.3106 0.0 2.080 0.646 VeI= 11.88 0.0 31.99 33.272 K Factor= 5.55 S012 31.73 1.049 IT 5.0 0.080 32.113 K Factor = 5.60 to 120 0.0 5.000 0.0 16 31.73 0.3057 0.0 5.080 1.553 VeI= 11.78 0.0 31.73 33.666 K Factor= 5.47 S013 32.40 1.049 IT 5.0 0.080 33.466 K Factor= 5.60 to 120 0.0 5.000 0.0 17 32.4 0.3175 0.0 5.080 1.613 Vel = 12.03 0.0 32.40 35.079 K Factor= 5.47 S014 27.31 1.049 1 2.0 0.080 23.784 K Factor =5.60 to 120 0.0 2.000 0.0 10 27.31 0.2317 0.0 2.080 0.482 Vel = 10.14 0.0 27.31 24.266 K Factor= 5.54 S015 27.09 1.049 IT 5.0 0.080 23.402 K Factor = 5.60 to 120 0.0 5.000 0.0 II 27.09 0.2281 0.0 5.080 1.159 VeI= 10.06 0.0 27.09 24.561 K Factor= 5.47 S016 27.67 1.049 1T 5.0 0.080 24.410 K Factor= 5.60 to 120 0.0 5.000 0.0 12 27.67 0.2372 0.0 5.080 1.205 Vel = 10.27 0.0 27.67 25.615 K Factor= 5.47 18 24.80 1.61 0.0 10.250 20.020 to 120 0.0 0.0 0.0 19 24.8 0.0241 0.0 10.250 0.247 Vel = 3.91 19 24.60 1.61 0.0 10.250 20.267 to 120 0.0 0.0 0.0 20 49.4 0.0860 0.0 10.250 0.882 Vel = 7.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Einal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 20 25.13 1.61 0.0 10.250 21.149 to 120 0.0 0.0 0.0 21 74.53 0.1842 0.0 10.250 1.888 VeI= 11.75 21 26.24 1.61 0.0 10.250 23.037 to 120 0.0 0.0 0.0 22 100.77 0.3218 0.0 10.250 3.298 Vel = 15.88 22 28.05 1.61 0.0 20.500 26.335 to 120 0.0 0.0 0.0 7A 128.82 0.5069 0.0 20.500 10.391 Vel = 20.30 7A 0.0 2.067 2T 20.0 12.125 36.726 to 120 0.0 20.000 0.940 7 128.82 0.1501 0.0 32.125 4.823 Vel = 12.32 0.0 128.82 42.489 KFactor= 19.76 15 31.99 1.61 0.0 10.250 33.272 to 120 0.0 0.0 0.0 16 31.99 0.0384 0.0 10.250 0.394 VeI= 5.04 16 31.73 1.61 0.0 10.250 33.666 to 120 0.0 0.0 0.0 17 63.72 0.1379 0.0 10.250 1.413 VeI= 10.04 17 32.40 1.61 2E 8.0 10.500 35.079 to 120 IT 8.0 16.000 0.940 8 96.12 0.2948 0.0 26.500 7.813 VeI= 15.15 0.0 96.12 43.832 KFactor= 14.52 10 27.31 1.61 0.0 10.250 24.266 to 120 0.0 0.0 0.0 II 27.31 0.0288 0.0 10.250 0295 Vel = 4.30 II 27.09 1.61 0.0 10.250 24.561 to 120 0.0 0.0 0.0 12 54.4 0.1028 0.0 10.250 1.054 Vel= 8.57 12 27.67 1.61 4E 16.0 40.950 25.615 to 120 IT 8.0 24.000 0.0 9A 82.07 0.2201 0.0 64.950 14.296 Vel = 12.93 9A 0.0 2.067 2T 20.0 15.210 39.911 to 120 0.0 20.000 0.940 9 82.07 0.0652 0.0 35.210 2.295 Vel = 7.85 0.0 82.07 43.146 KFactor= 12.49 1 24.75 1.61 0.0 10.250 19.928 to 120 0.0 0.0 0.0 2 24.75 0.0239 0.0 10.250 0.245 Vel = 3.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Einal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 24.54 1.61 0.0 10.250 20.173 to 120 0.0 0.0 0.0 3 49.29 0.0858 0.0 10.250 0.879 Vel = 7.77 3 25.07 1.61 0.0 10.250 21.052 to 120 0.0 0.0 0.0 4 74.36 0.1834 0.0 10.250 1.880 VeI= 11.72 4 26.18 1.61 0.0 10.250 22.932 to 120 0.0 0.0 0.0 5 100.54 0.3204 0.0 10.250 3.284 Vel = 15.84 5 27.99 1.61 0.0 20.500 26.216 to 120 0.0 0.0 0.0 6A 128.53 0.5047 0.0 20.500 10.346 Vel = 20.26 6A 0.0 2.067 2T 20.0 12.125 36.562 to 120 0.0 20.000 0.940 6 128.53 0.1495 0.0 32.125 4.802 Vel = 12.29 6 0.0 3.26 0.0 11.330 42.304 to 120 0.0 0.0 0.0 7 128.53 0.0163 0.0 11.330 0.185 VeI= 4.94 7 128.82 3.26 0.0 10.330 42.489 to 120 0.0 0.0 0.0 8A 257.35 0.0587 0.0 10.330 0.606 Vel = 9.89 8A -76.54 3.26 0.0 1.670 43.095 to 120 0.0 0.0 0.0 9 180.81 0.0305 0.0 1.670 0.051 VeI= 6.95 9 82.07 3.26 2E 18.815 244.700 43.146 to 120 IT 20.159 38.974 0.0 Fl 262.88 0.0611 0.0 283.674 17.325 VeI= 10.10 0.0 262.88 60.471 K Factor= 33.81 138 21.42 1.38 4T 24.0 182.000 43.614 to 120 0.0 24.000 0.217 118 21.42 0.0389 0.0 206.000 8.006 VeI= 4.59 0.0 21.42 51.837 KFactor= 2.98 137 20.48 1.38 3E 9.0 189.000 43.541 to 120 ST 30.0 39.000 0.217 119 20.48 0.0358 0.0 228.000 8.153 Vel = 4.39 0.0 20.48 51.911 K Factor = 2.84 136 19.90 1.38 7E 21.0 225.250 43.463 to 120 3T 18.0 39.000 0.217 120 19.9 0.0339 0.0 264.250 8.961 Vel = 4.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 19.90 52.641 KFactor= 2.74 126 19.85 1.38 4T 24.0 221.500 43.789 to 120 0.0 24.000 0.217 112 19.85 0.0337 0.0 245.500 8.282 Vet= 4.26 0.0 19.85 52.288 K Factor= 2.75 122 20.47 1.38 4T 24.0 213.500 43.689 to 120 0.0 24.000 0.217 113 20.47 0.0357 0.0 237.500 8.482 Vet = 4.39 0.0 20.47 52.388 K Factor = 2.83 121 20.44 1.38 3E 9.0 219.250 43.499 to 120 3T 18.0 27.000 0.217 114 20.44 0.0356 0.0 246.250 8.776 Vel = 4.38 0.0 20.44 52.492 K Factor = 2.82 101 -29.63 2.635 0.0 12.750 43.828 to 120 0.0 0.0 0.0 126 -29.63 -0.0031 0.0 12.750 -0.039 Vet = 1.74 126 -19.84 2.635 0.0 12.750 43.789 to 120 0.0 0.0 0.0 122 -49.47 -0.0078 0.0 12.750 -0.100 Vel = 2.91 122 -20.47 2.635 0.0 12.750 43.689 to 120 0.0 0.0 0.0 121 -69.94 -0.0149 0.0 12.750 -0.190 Vet= 4.11 121 -20.44 2.635 0.0 8.250 43.499 to 120 0.0 0.0 0.0 121A -90.38 -0.0239 0.0 8.250 -0.197 Vet = 5.32 121A 172.65 2.635 0.0 8.000 43.302 to 120 0.0 0.0 0.0 136 82.27 0.0201 0.0 8.000 0.161 Vel = 4.84 136 -19.90 2.635 0.0 6.500 43.463 to 120 0.0 0.0 0.0 137 62.37 0.0120 0.0 6.500 0.078 Vet = 3.67 137 -20.48 2.635 0.0 12.750 43.541 to 120 0.0 0.0 0.0 138 41.89 0.0057 0.0 12.750 0.073 Vet = 2.46 138 -21.42 2.635 0.0 12.750 43.614 to 120 0.0 0.0 0.0 116 20.47 0.0016 0.0 12.750 0.020 .Vel= 1.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page II BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 116 0.0 1.38 4E 12.0 187.000 43.634 to 120 4T 24.0 36.000 0.217 117 20.47 0.0357 0.0 223.000 7.967 Vel = 4.39 117 0.0 2.635 0.0 12.750 51.818 to 120 0.0 0.0 0.0 118 20.47 0.0015 0.0 12.750 0.019 VeI= 1.20 118 21.42 2.635 0.0 12.750 51.837 to 120 0.0 0.0 0.0 119 41.89 0.0058 0.0 12.750 0.074 Vel= 2.46 119 20.48 2.635 2E 16.474 44.250 51.911 to 120 0.0 16.474 0.0 120 62.37 0.0120 0.0 60.724 0.730 VeI= 3.67 120 19.90 2.635 IT 16.474 6.590 52.641 to 120 0.0 16.474 0.0 115 82.27 0.0201 0.0 23.064 0.463 Vel = 4.84 0.0 82.27 53.104 KFactor= 11.29 121A -172.65 2.635 2E 16.474 10.920 43.302 to 120 IT 16.474 32.948 0.0 180 -172.65 -0.0791 0.0 43.868 -3.470 Vel = 10.16 180 0.0 2.635 IE 8.237 14.500 39.832 to 120 0.0 8.237 6.280 181 -172.65 -0.0791 0.0 22.737 -1.799 Vel = 10.16 181 0.0 2.635 0.0 6.080 44.313 to 120 0.0 0.0 0.0 8 -172.65 -0.0791 0.0 6.080 -0.481 Vel = 10.16 8 96.11 2.635 IT 16.474 25.500 43.832 to 120 0.0 16.474 0.0 8A -76.54 -0.0176 0.0 41.974 -0.737 Vel = 4.50 0.0 -76.54 43.095 K Factor = -11.66 101 29.63 1.61 4T 32.0 213.500 43.828 to 120 0.0 32.000 0.217 III 29.63 0.0334 0.0 245.500 8.204 Vel = 4.67 111 0.0 2.635 0.0 12.750 52.249 to 120 0.0 0.0 0.0 112 29.63 0.0031 0.0 12.750 0.039 Vel= 1.74 112 19.84 2.635 0.0 12.750 52.288 to 120 0.0 0.0 0.0 113 49.47 0.0078 0.0 12.750 0.100 VeI= 2.91 113 20.47 2.635 0.0 7.000 52.388 to 120 0.0 0.0 0.0 114 69.94 0.0149 0.0 7.000 0.104 VeI= 4.11 Computer Programs by Hydratec Inc. Route 111 Windham N. H. USA 03087 inaI Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 114 20.44 2.635 IT 16.474 9.160 52.492 to 120 0.0 16.474 0.0 115 90.38 0.0239 0.0 25.634 0.612 Vel = 5.32 115 82.27 3.26 1 9.408 23.040 53.104 to 120 0.0 9.408 0.0 TRA 172.65 0.0280 0.0 32.448 0.910 Vel = 6.64 TRA 0.0 3.26 0.0 14.000 54.014 to 120 0.0 0.0 6.063 Fl 172.65 0.0281 0.0 14.000 0.394 Vel = 6.64 Fl 262.89 4.26 2E 26.334 12.000 60.471 to 120 IZ 13.167 39.501 4.331 BRA 435.54 0.0422 0.0 51.501 2.175 Vel = 9.80 BRA 0.0 6.16 1 20.084 4.000 66.977 to 140 0.0 20.084 1.732 A 435.54 0.0053 0.0 24.084 0.127 Vel = 4.69 A 0.0 6.09 2F 21.583 81.000 68.836 to 150 2E 43.166 64.749 0.0 BF2 435.54 0.0049 0.0 145.749 0.714 Vel = 4.80 BF2 0.0 6.16 2E 40.168 16.000 69.550 to 140 IT 43.037 83.205 3.000 * Fixed loss = 3 BFI 435.54 0.0053 0.0 99.205 0.523 Vel = 4.69 BFI 0.0 6.09 1 4.625 20.000 73.073 to 150 IT 46.249 50.874 0.0 B 435.54 0.0049 0.0 70.874 0.348 Vel = 4.80 B -26.05 9.79 3G 20.242 512.000 73.421 Qa = 250 to 150 1 29.689 132.249 0.0 E 409.49 0.0004 IF 14.844 644.249 0.279 Vel= 1.75 IT 67.474 0.0 409.49 73.700 K Factor = 47.70 B 276.05 9.79 1 29.689 133.000 73.421 to 150 0.0 29.688 0.0 D 276.05 0.0002 0.0 162.688 0.034 Vel = 1.18 D 0.0 9.79 6G 40.485 932.000 73.455 to 150 2E 59.378 241.559 0.0 E 276.05 0.0002 5F 74.222 1173.559 0.245 VeI= 1.18 IT 67.474 E 409.49 9.79 1 29.689 272.000 73.700 to 150 IF 14.844 118.754 5.847 TEST 685.54 0.0011 1 6.747 390.754 0.439 Vel = 2.92 IT 67.474 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 13 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 685.54 79.986 KFactor= 76.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A AL F.W.. tl..M. I - - - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER CO. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 16 Building BUILDING A Location : 2548 CAMPBELL PLACE System : REMOTE AREA2 Contract Data File : Bressi-3.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 16 Date 9/5/06 Hydraulic Design Information Sheet Name - BRESSI RANCH LOT 16 Date - 9/5/06 Location - 2548 CAMPBELL PLACE Building - BUILDING A System No. - REMOTE AREA2 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - Calculated By - M.G. Drawing No. - FP-3 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - VARIES Occupancy - ORDINARY GROUP 2 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (X) Wet Make GLOBE D Area Per Sprinkler - 102 MAX. ( ) Dry Model GL E Elevation at Highest Outlet - 28'8.5 ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground Water Flow Test: Date of Test -'9/5/06 Time of Test - Static Press - 90 Residual Press'- 88 Flow - 1272 Elevation - 323.0 Location - CAMPBELL PLACE Pump Data: Tank or Reservoir: Cap. - Rated Cap.- Elev.- @ Press - Elev. - Well Proof Flow W A T E R S U P P L Y Source of Information - PERFORMED BY I.F.S., WITNESSED BY CARLSBAD WATER DIST C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. SR Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non TA Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 16 Date 9/5/06 City Water Supply: Demand: Cl - Static Pressure : 90 Dl - Elevation : 19.381 C2 - Residual Pressure: 88 D2 - System Flow : 396.891 stem Pressure : 80.127 C2 - Residual Flow : 1272 D2 - S~'Deman Hose dj City) ______ Hose d') : 250 D3 - System Demand : 646.891 Safety Margin : 9.301 150 140 130 p120 R11° E10° Cl __ C2 s90 D2 S80 ' U7° R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 16 Date 9/5/06 Fitting Legend Abbrev. Name ½ % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER Co. Page 4 BRESSI RANCH LOT 16 Date 9/5/06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SOOI 28.25 5.6 14.46 na 21.3 0.2 102 7.0 S002 27.75 5.6 15.2 na 21.83 0.2 102 7.0 S003 28.25 5.6 13.52 na 20.59 0.2 102 7.0 S004 27.75 5.6 13.93 na 20.9 0.2 102 7.0 S005 28.0 5.6 12.2 na 19.56 0.2 83 7.0 S006 28.7 5.6 26.82 na 29.0 0.2 102 7.0 S007 28.25 5.6 13.27 na 20.4 0.2 102 7.0 S008 27.75 5.6 13.59 na 20.64 0.2 102 7.0 S009 28.0 5.6 11.98 na 19.38 0.2 83 7.0 SOlO 28.7 5.6 26.72 na 28.95 0.2 102 7.0 SOIl 28.25 5.6 13.27 na 20.4 0.2 102 7.0 S012 27.75 5.6 13.57 na 20.63 0.2 102 7.0 S013 28.7 5.6 26.92 na 29.05 0.2 102 7.0 S014 28.25 5.6 13.57 na 20.63 0.2 102 7.0 S015 27.75 5.6 13.84 na 20.83 0.2 102 7.0 S016 28.0 5.6 12.61 na 19.89 0.2 83 7.0 S017 28.25 5.6 14.6 na 21.4 0.2 102 7.0 S018 27.75 5.6 14.77 na 21.52 0.2 102 7.0 138 25.5 46.37 na 137 . 25.5 46.33 na 136 25.5 46.28 na 135 27.0 13.0 na 134 27.0 12.78 na 133 27.0 13.43 na 126 25.5 43.4 na 201 28.25 28.26 na 202 28.25 26.09 na 203 28.25 23.91 na 204 28.25 21.73 na 205 28.25 19.56 na 206 28.25 17.38 na 127 28.25 15.2 na 128 28.25 14.22 na 129 28.25 13.96 na 130 28.25 13.96 na 131 28.25 14.27 na 132 28.25 15.35 na 122 25.5 44.21 na 207 28.7 36.29 na 208 28.7 35.27 na 209 28.7 34.25 na 210 28.7 33.23 na 211 28.7 32.21 na 212 28.7 31.19 na 123 28.7 28.13 na 124 28.7 28.03 na 125 28.7 28.24 na 121 25.5 45.47 na 213 29.17 44.69 na 214 29.17 44.8 na 215 29.17 44.91 na 216 29.17 45.02 na 101 25.5 43.08 na 121A 25.5 46.19 na 116 25.5 46.38 na 117 25.0 51.32 na 118 25.0 51.33 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 16 Date 9/5/06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 119 25.0 51.38 na 120 25.0 51.81 na 180 25.5 47.97 na 181 11.0 55.17 na 8 11.0 55.41 na 8A 11.0 57.12 na 9 11.0 57.18 na 102 27.75 15.98 na 103 27.75 14.65 na 104 27.75 14.51 na 105 27.75 14.29 na 106 27.75 14.26 na 107 27.75 14.27 na 108 27.75 14.55 na 109 27.75 15.0 na 110 27.75 15.53 na 111 25.0 47.15 na 112 25.0 47.47 na 113 25.0 48.31 na 114 25.0 49.05 na 115 25.0 52.08 na TRA 25.0 54.26 na Fl 11.0 61.26 na BRA 1.0 67.46 na A -3.0 69.3 na BF2 -3.0 69.9 na BF1 -3.0 73.34 na B -3.0 73.63 na 250.0 D -3.0 73.67 na E -3.0 73.89 na TEST -16.5 80.13 na The maximum velocity is 14.62 and it occurs in the pipe between nodes 110 and 111 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn SOOI 21.30 1.049 IT 5.0 0.080 14.462 K Factor = 5.60 to 120 0.0 5.000 0.0 127 21.3 0.1463 0.0 5.080 0.743 Vel = 7.91 0.0 21.30 15.205 K Factor = 5.46 S002 21.83 1.049 IT 5.0 0.080 15.203 K Factor= 5.60 to 120 0.0 5.000 0.0 102 21.83 0.1530 0.0 5.080 0.777 Vel= 8.10 0.0 21.83 15.980 KFactor= 5.46 S003 20.59 1.049 IT 5.0 0.080 13.518 K Factor= 5.60 to 120 0.0 5.000 0.0 128 20.59 0.1374 0.0 5.080 0.698 Vel = 7.64 0.0 20.59 14.216 KFactor= 5.46 S004 20.90 1.049 IT 5.0 0.080 13.930 K Factor= 5.60 to 120 0.0 5.000 0.0 103 20.9 0.1413 0.0 5.080 0.718 Vel = 7.76 0.0 20.90 14.648 K Factor= 5.46 S005 19.56 1.049 IE 2.0 1.000 12.196 K Factor = 5.60 to 120 0.0 2.000 0.433 135 19.56 0.1247 0.0 3.000 0.374 Vel = 7.26 0.0 19.56 13.003 K Factor= 5.42 S006 29.00 1.049 IT 5.0 0.080 26.817 K Factor = 5.60 to 120 0.0 5.000 0.0 123 29.0 0.2587 0.0 5.080 1.314 Vel= 10.77 0.0 29.00 28.131 KFactor= 5.47 S007 20.40 1.049 IT 5.0 0.080 13.270 K Factor = 5.60 to 120 0.0 5.000 0.0 129 20.4 0.1350 0.0 5.080 0.686 Vel = 7.57 0.0 20.40 13.956 K Factor= 5.46 S008 20.64 1.049 IT 5.0 0.080 13.590 K Factor= 5.60 to 120 0.0 5.000 0.0 105 20.64 0.1380 0.0 5.080 0.701 Vel = 7.66 0.0 20.64 14.291 K Factor= 5.46 S009 19.38 1.049 1E 2.0 1.000 11.980 K Factor = 5.60 to 120 0.0 2.000 0.433 134 19.38 0.1230 0.0 3.000 0.369 Vel= 7.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 19.38 12.782 KFactor= 5.42 5010 28.95 1.049 iT 5.0 0.080 26.719 K Factor = 5.60 to 120 0.0 5.000 0.0 124 28.95 0.2579 0.0 5.080 1.310 Vel = 10.75 0.0 28.95 28.029 K Factor = 5.47 SOIl 20.40 1.049 IT 5.0 0.080 13.271 K Factor= 5.60 to 120 0.0 5.000 0.0 130 20.4 0.1350 0.0 5.080 0.686 Vel= 7.57 0.0 20.40 13.957 K Factor= 5.46 S012 20.63 1.049 IT 5.0 0.080 13.566 K Factor = 5.60 to 120 0.0 5.000 0.0 107 20.63 0.1376 0.0 5.080 0.699 Vel = 7.66 0.0 20.63 14.265 K Factor= 5.46 S0I3 29.05 1.049 IT 5.0 0.080 26.918 K Factor = 5.60 to 120 0.0 5.000 0.0 125 29.05 0.2596 0.0 5.080 1.319 Vel = 10.78 0.0 29.05 28.237 K Factor = 5.47 S014 20.63 1.049 IT 5.0 0.080 13.566 K Factor = 5.60 to 120 0.0 5.000 0.0 131 20.63 0.1378 0.0 5.080 0.700 Vel = 7.66 0.0 20.63 14.266 K Factor = 5.46 S015 20.83 1.049 1T 5.0 0.080 13.835 K Factor= 5.60 to 120 0.0 5.000 0.0 108 20.83 0.1404 0.0 5.080 0.713 Vel = 7.73 0.0 20.83 14.548 K Factor = 5.46 S016 19.89 1.049 1E 2.0 1.000 12.610 K Factor = 5.60 to 120 0.0 2.000 0.433 133 19.89 0.1290 0.0 3.000 0.387 Vel = 7.38 0.0 19.89 13.430 K Factor= 5.43 S017 21.40 1.049 IT 5.0 0.080 14.597 K Factor = 5.60 to 120 0.0 5.000 0.0 132 21.4 0.1474 0.0 5.080 0.749 Vel = 7.94 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 21.40 15.346 KFactor= 5.46 S018 21.52 1.049 IT 5.0 0.080 14.769 K Factor = 5.60 to 120 0.0 5.000 0.0 110 21.52 0.1490 0.0 5.080 0.757 VeI= 7.99 0.0 21.52 15.526 KFactor= 5.46 138 16.14 1.38 4T 24.0 182.000 46.373 to 120 0.0 24.000 0.217 118 16.14 0.0230 0.0 206.000 4.742 Vel= 3.46 0.0 16.14 51.332 K Factor = 2.25 137 15.43 1.38 3E 9.0 189.000 46.329 to 120 5T 30.0 39.000 0.217 119 15.43 0.0212 0.0 228.000 4.830 Vel= 3.31 0.0 15.43 51.376 KFactor= 2.15 136 15.00 1.38 7E 21.0 225.250 46.283 to 120 3T 18.0 39.000 0.217 120 15.0 0.0201 0.0 264.250 5.309 Vel = 3.22 0.0 15.00 51.809 KFactor= 2.08 135 19.56 1.049 IE 2.0 7.700 13.003 to 120 IT 5.0 7.000 -0.325 104 19.56 0.1249 0.0 14.700 1.836 Vel= 7.26 0.0 19.56 14.514 KFactor= 5.13 134 19.38 1.049 IE 2.0 7.700 12.782 to 120 IT 5.0 7.000 -0.325 106 19.38 0.1228 0.0 14.700 1.805 Vel= 7.19 0.0 19.38 14.262 K Factor= 5.13 133 19.89 1.049 IE 2.0 7.700 13.430 to 120 IT 5.0 7.000 -0.325 109 19.89 0.1288 0.0 14.700 1.893 Vel = 7.38 0.0 19.89 14.998 KFactor= 5.14 126 -61.33 1.38 2T 12.0 39.250 43.395 to 120 0.0 12.000 -1.191 201 -61.33 -0.2720 0.0 51.250 -13.942 Vel = 13.16 201 0.0 1.38 0.0 8.000 28.262 to 120 0.0 0.0 0.0 202 -61.33 -0.2720 0.0 8.000 -2.176 Vel = 13.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 202 0.0 1.38 0.0 8.000 26.086 to 120 0.0 0.0 0.0 203 -61.33 -0.2720 0.0 8.000 -2.176 Vet = 13.16 203 0.0 1.38 0.0 8.000 23.910 to 120 0.0 0.0 0.0 204 -61.33 -0.2721 0.0 8.000 -2.177 Vet = 13.16 204 0.0 1.38 0.0 8.000 21.733 to 120 0.0 0.0 0.0 205 -61.33 -0.2720 0.0 8.000 -2.176 Vet = 13.16 205 0.0 1.38 0.0 8.000 19.557 to 120 0.0 0.0 0.0 206 -61.33 -0.2720 0.0 8.000 -2.176 Vet = 13.16 206 0.0 1.38 0.0 8.000 17.381 to 120 0.0 0.0 0.0 127 -61.33 -0.2720 0.0 8.000 -2.176 Vet = 13.16 127 21.30 1.38 0.0 8.000 15.205 to 120 0.0 0.0 0.0 128 -40.03 -0.1236 0.0 8.000 -0.989 Vet = 8.59 128 20.59 1.38 0.0 8.000 14.216 to 120 0.0 0.0 0.0 129 -19.44 -0.0325 0.0 8.000 -0.260 Vet = 4.17 129 20.40 1.38 0.0 8.000 13.956 to 120 0.0 0.0 0.0 130 0.96 0.0001 0.0 8.000 0.001 Vet = 0.21 130 20.40 1.38 0.0 8.000 13.957 to 120 0.0 0.0 0.0 131 21.36 0.0386 0.0 8.000 0.309 VeI= 4.58 131 20.62 1.38 0.0 8.000 14.266 to 120 0.0 0.0 0.0 132 41.98 0.1350 0.0 8.000 1.080 Vet = 9.00 132 21.40 1.38 2T 12.0 94.250 15.346 to 120 0.0 12.000 1.408 112 63.38 0.2891 0.0 106.250 30.716 Vet = 13.60 0.0 63.38 47.470 K Factor= 9.20 122 -40.71 1.38 2T 12.0 39.250 44.209 to 120 0.0 12.000 -1.386 207 -40.71 -0.1275 0.0 51.250 -6.533 Vet = 8.73 207 0.0 1.38 0.0 8.000 36.290 to 120 0.0 0.0 0.0 208 -40.71 -0.1275 0.0 8.000-1.020 Vet = 8.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard 'INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 208 0.0 1.38 0.0 8.000 35.270 to 120 0.0 0.0 0.0 209 -40.71 -0.1275 0.0 8.000 -1.020 Vel = 8.73 209 0.0 1.38 0.0 8.000 34.250 to 120 0.0 0.0 0.0 210 -40.71 -0.1275 0.0 8.000 -1.020 Vel= 8.73 210 0.0 1.38 0.0 8.000 33.230 to 120 0.0 0.0 0.0 211 -40.71 -0.1274 0.0 8.000 -1.019 VeI= 8.73 211 0.0 1.38 0.0 8.000 32.211 to 120 0.0 0.0 0.0 212 -40.71 -0.1275 0.0 8.000 -1.020 Vel = 8.73 212 0.0 1.38 0.0 24.000 31.191 to 120 0.0 0.0 0.0 123 -40.71 -0.1275 0.0 24.000 -3.060 Vel = 8.73 123 29.00 1.38 0.0 8.000 28.131 to 120 0.0 0.0 0.0 124 -11.71 -0.0127 0.0 8.000 -0.102 VeI= 2.51 124 28.94 1.38 0.0 8.000 28.029 to 120 0.0 0.0 0.0 125 17.23 0.0260 0.0 8.000 0.208 Vel = 3.70 125 29.06 1.38 2T 12.0 102.250 28.237 to 120 0.0 12.000 1.602 113 46.29 0.1616 0.0 114.250 18.468 VeI= 9.93 0.0 46.29 48.307 K Factor= 6.66 121 12.18 1.38 2T 12.0 47.250 45.466 to 120 0.0 12.000 -1.589 213 12.18 0.0137 0.0 59.250 0.810 Vel = 2.61 213 0.0 1.38 0.0 8.000 44.687 to 120 0.0 0.0 0.0 214 12.18 0.0136 0.0 8.000 0.109 Vel = 2.61 214 0.0 1.38 0.0 8.000 44.796 to 120 0.0 0.0 0.0 215 12.18 0.0138 0.0 8.000 0.110 VeI= 2.61 215 0.0 1.38 0.0 8.000 44.906 to 120 0.0 0.0 0.0 216 12.18 0.0136 0.0 8.000 0.109 VeI= 2.61 216 0.0 1.38 3E 9.0 148.000 45.015 to 120 IT 6.0 15.000 1.806 114 12.18 0.0137 0.0 163.000 2.229 VeI= 2.61 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 11 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12.18 49.050 KFactor= 1.74 101 92.43 2.635 0.0 12.750 43.078 to 120 0.0 0.0 0.0 126 92.43 0.0249 0.0 12.750 0.317 Vel= 5.44 126 61.33 2.635 0.0 12.750 43.395 to 120 0.0 0.0 0.0 122 153.76 0.0638 0.0 12.750 0.814 Vel = 9.05 122 40.71 2.635 0.0 12.750 44.209 to 120 0.0 0.0 0.0 121 194.47 0.0986 0.0 12.750 1.257 Vel= 11.44 121 -12.18 2.635 0.0 8.250 45.466 to 120 0.0 0.0 0.0 121A 182.29 0.0875 0.0 8.250 0.722 Vel = 10.72 121A -120.29 2.635 0.0 8.000 46.188 to 120 0.0 0.0 0.0 136 62.0 0.0119 0.0 8.000 0.095 Vel = 3.65 136 -15.00 2.635 0.0 6.500 46.283 to 120 0.0 0.0 0.0 137 47.0 0.0071 0.0 6.500 0.046 Vel = 2.77 137 -15.43 2.635 0.0 12.750 46.329 to 120 0.0 0.0 0.0 138 31.57 0.0035 0.0 12.750 0.044 Vel= 1.86 138 -16.15 2.635 0.0 12.750 46.373 to 120 0.0 0.0 0.0 116 15.42 0.0009 0.0 12.750 0.011 Vel = 0.91 116 0.0 1.38 4E 12.0 187.000 46.384 to 120 4T 24.0 36.000 0.217 117 15.42 0.0212 0.0 223.000 4.720 Vel = 3.31 117 0.0 2.635 0.0 12.750 51.321 to 120 0.0 0.0 0.0 118 15.42 0.0009 0.0 12.750 0.011 Vel = 0.91 118 16.15 2.635 0.0 12.750 51.332 to 120 0.0 0.0 0.0 119 31.57 0.0035 0.0 12.750 0.044 Vel= 1.86 119 15.43 2.635 2E 16.474 44.250 51.376 to 120 0.0 16.474 0.0 120 47.0 0.0071 0.0 60.724 0.433 Vel = 2.77 120 15.00 2.635 IT 16.474 6.590 51.809 to 120 0.0 16.474 0.0 115 62.0 0.0119 0.0 23.064 0.274 Vel = 3.65 0.0 62.00 52.083 K Factor = 8.59 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 121A 120.29 2.635 2E 16.474 10.920 46.188 to 120 IT 16.474 32.948 0.0 180 120.29 0.0405 0.0 43.868 1.778 Vel= 7.08 180 0.0 2.635 1 8.237 14.500 47.966 to 120 0.0 8.237 6.280 181 120.29 0.0406 0.0 22.737 0.922 Vel = 7.08 181 0.0 2.635 0.0 6.080 55.168 to 120 0.0 0.0 0.0 8 120.29 0.0405 0.0 6.080 0.246 Vel = 7.08 8 0.0 2.635 IT 16.474 25.500 55.414 to 120 0.0 16.474 0.0 8A 120.29 0.0405 0.0 41.974 1.702 Vel = 7.08 8A 0.0 2.635 0.0 1.670 57.116 to 120 0.0 0.0 0.0 9 120.29 0.0407 0.0 1.670 0.068 Vel = 7.08 9 0.0 3.26 2E 18.815 244.700 57.184 to 120 IT 20.159 38.974 0.0 Fl 120.29 0.0144 0.0 283.674 4.079 Vel = 4.62 0.0 120.29 61.263 KFactor= 15.37 101 -92.43 1.61 2T 16.0 79.250 43.078 to 120 0.0 16.000 -0.974 102 -92.43 -0.2743 0.0 95.250 -26.124 Vel = 14.57 102 21.84 1.61 0.0 8.000 15.980 to 120 0.0 0.0 0.0 103 -70.59 -0.1665 0.0 8.000 -1.332. Vel = 11.12 103 20.90 1.61 0.0 1.540 14.648 to 120 0.0 0.0 0.0 104 -49.69 -0.0870 0.0 1.540 -0.134 Vel = 7.83 104 19.55 1.61 0.0 6.450 14.514 to 120 0.0 0.0 0.0 105 -30.14 -0.0346 0.0 6.450 -0.223 Vel = 4.75 105 20.65 1.61 0.0 7.200 14.291 to 120 0.0 0.0 0.0 106 -9.49 -0.0040 0.0 7.200 -0.029 Vel = 1.50 106 19.38 1.61 0.0 0.790 14.262 to 120 0.0 0.0 0.0 107 9.89 0.0038 0.0 0.790 0.003 Vel = 1.56 107 20.63 1.61 0.0 8.000 14.265 to 120 0.0 0.0 0.0 108 30.52 0.0354 0.0 8.000 0.283 Vel = 4.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 13 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 108 20.83 1.61 0.0 4.870 14.548 to 120 0.0 0.0 0.0 109 51.35 0.0924 0.0 4.870 0.450 Vet = 8.09 109 19.88 1.61 0.0 3.120 14.998 to 120 0.0 0.0 0.0 110 71.23 0.1692 0.0 3.120 0.528 Vel = 11.23 110 21.52 1.61 2T 16.0 94.250 15.526 to 120 0.0 16.000 1.191 111 92.75 0.2760 0.0 110.250 30.433 VeI= 14.62 111 0.0 2.635 0.0 12.750 47.150 to 120 0.0 0.0 0.0 112 92.75 0.0251 0.0 12.750 0.320 Vet = 5.46 112 63.38 2.635 0.0 12.750 47.470 to 120 0.0 0.0 0.0 113 156.13 0.0656 0.0 12.750 0.837 Vel= 9.19 113 46.29 2.635 0.0 7.000 48.307 to 120 0.0 0.0 0.0 114 202.42 0.1061 0.0 7.000 0.743 Vel= 11.91 114 12.18 2.635 iT 16.474 9.160 49.050 to 120 0.0 16.474 0.0 115 214.6 0.1183 0.0 25.634 3.033 Vel= 12.63 115 62.00 3.26 1 9.408 23.040 52.083 to 120 0.0 9.408 0.0 TRA 276.6 0.0671 0.0 32.448 2.177 Vel = 10.63 TRA 0.0 3.26 0.0 14.000 54.260 to 120 0.0 0.0 6.063 Fl 276.6 0.0671 0.0 14.000 0.940 Vel = 10.63 Fl 120.29 4.26 2E 26.334 13.000 61.263 to 120 IZ 13.167 39.501 4.331 BRA 396.89 0.0356 0.0 52.501 1.867 Vel= 8.93 BRA 0.0 6.16 1 20.084 4.000 67.461 to 140 0.0 20.084 1.732 A 396.89 0.0044 0.0 24.084 0.107 Vet = 4.27 A 0.0 6.09 2F 21.583 81.000 69.300 to 150 2E 43.166 64.749 0.0 BF2 396.89 0.0041 0.0 145.749 0.602 Vel = 4.37 BF2 0.0 6.16 2E 40.168 16.000 69.902 to 140 IT 43.037 83.205 3.000 * Fixed loss = 3 BFI 396.89 0.0044 0.0 99.205 0.440 Vet = 4.27 BF1 0.0 6.09 IG 4.625 20.000 73.342 to 150 IT 46.249 50.874 0.0 B 396.89 0.0041 0.0 70.874 0.293 Vet = 4.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 14 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn B -10.48 9.79 3G 20.242 512.000 73.635 Qa = 250 to 150 1 29.689 132.249 0.0 E 386.41 0.0004 IF 14.844 644.249 0.251 VeI= 1.65 IT 67.474 0.0 386.41 73.886 KFactor= 44.95 B 260.48 9.79 1 29.689 133.000 73.635 to 150 0.0 29.688 0.0 D 260.48 0.0002 0.0 162.688 0.030 Vel= 1.11 D 0.0 9.79 6G 40.485 932.000 73.665 to 150 2E 59.378 241.559 0.0 E 260.48 0.0002 5F 74.222 1173.559 0.221 VeI= 1.11 IT 67.474 E 386.41 9.79 1E 29.689 272.000 73.886 to 150 IF 14.844 118.754 5.847 TEST 646.89 0.0010 IG 6.747 390.754 0.394 Vel = 2.76 IT 67.474 0.0 646.89 80.127 KFactor= 72.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary INDUSTRIAL FIRE SPRINKLER CO. Page 15 BRESSI RANCH LOT 16 Date 9/5/06 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length 126 201 39.250 132 112 94.250 122 207 39.250 125 113 102.250 101 102 79.250 110 111 94.250 Flow Pressure Pressure Required Required Differential Left 8.000 I 646.834 79.939 -0.188 Area Calculated I 646.891 80.127 0.000 Right 8.000 1 646.897 80.125 -0.002 Typical Distance Between Heads = 8.000 Split Point Used in Worst Area Peaked = S007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design INDUSTRIAL FIRE SPRINKLER Co. 3845 IMPERIAL AVE. SAN DIEGO, CA 92113 619-266-6030 Job Name : BRESSI RANCH LOT 16 Building -- BUlLDINGA— Location 548 CAMPBELL PLACED System : REMOTEAREA3 - - Contract Data File Bressi-4.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INDUSTRIAL FIRE SPRINKLER CO. Page 1 BRESSI RANCH LOT 16 Date 9/5/06 Hydraulic Design Information Sheet Name - BRESSI RANCH LOT 16 Date - 9/5/06 Location - 2548 CAMPBELL PLACE Building - BUILDING A System No. - REMOTE AREA3 Contractor - INDUSTRIAL FIRE SPRINKELR CO. Contract No. - Calculated By - M.G. Drawing No. - FP-3 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - VARIES Occupancy - ORDINARY GROUP 2 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (X) Wet Make GLOBE D Area Per Sprinkler . - 102 MAX. ( ) Dry Model GL E Elevation at Highest Outlet - 292" ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - Press Required - Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9/5/06 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 90 8 Press - R Residual Press - 88 Elev. - Well Flow - 1272 Proof Flow S Elevation - 323.0 U P Location - CAMPBELL PLACE P L Source of Information - PERFORMED BY I.F.S., WITNESSED BY CARLSBAD WATER DIST Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) INDUSTRIAL FIRE SPRINKLER CO. Page 2 BRESSI RANCH LOT 16 Date 9/5/06 City Water Supply: Demand: CI - Static Pressure : 90 Dl - Elevation : 19.576 C2 - Residual Pressure: 88 D2 - System Flow : 358.293 stem Pressure : 76.987 C2 - Residual Flow : 1272 D2 - SrDeman4 Hose Adj City ________ Hose : 250 D3 - System Demand : 608.293 Safety Margin : 12.502 150 140 -. 130 P 120 R110 100 . C2 90 02 80 - u 70 7' D R60 E5° 40 30 20 D1 I 10 _, __I_.._ ...l I I I 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary INDUSTRIAL FIRE SPRINKLER CO. Page 3 BRESSI RANCH LOT 16 Date 9/5/06 Fitting Legend Abbrev. Name ½ Y4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90FlowThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD INDUSTRIAL FIRE SPRINKLER CO. Page 4 BRESSI RANCH LOT 16 Date 9/5/06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 21.48 0.2 102 7.0 20.7 0.2 102 7.0 20.46 0.2 102 7.0 20.46 0.2 102 7.0 20.65 0.2 102 7.0 21.34 0.2 102 7.0 21.41 0.2 102 7.0 20.63 0.2 102 7.0 20.4 0.2 102 7.0 20.4 0.2 102 7.0 20.59 0.2 102 7.0 21.28 0.2 102 7.0 27.55 0.2 102 7.0 27.0 0.2 102 7.0 26.93 0.2 102 7.0 27.01 0.2 102 7.0 S21 27.75 5.6 14.71 na S22 27.75 5.6 13.66 na S23 27.75 5.6 13.35 na S24 27.75 5.6 13.35 na S25 27.75 5.6 13.59 na S26 27.75 5.6 14.53 na S27 28.7 5.6 14.62 na S28 28.7 5.6 13.57 na S29 28.7 5.6 13.27 na S30 28.7 5.6 13.27 na S31 28.7 5.6 13.51 na S32 28.7 5.6 14.44 na S33 29.17 5.6 24.21 na S34 29.17 5.6 23.25 na S35 29.17 5.6 23.13 na S36 29.17 5.6 23.26 na 138 25.5 44.63 na 137 25.5 44.59 na 136 255 44.55 na 126 25.5 43.27 na 201 28.25 15.25 na 202 28.25 14.15 na 203 28.25 13.83 na 204 28.25 13.82 na 205 28.25 14.08 na 206 28.25 15.05 na 127 28.25 17.22 na 128 28.25 19.38 na 129 28.25 21.54 na 130 28.25 23.71 na 131 28.25 25.87 na 132 28.25 28.03 na 122 25.5 43.35 na 207 28.7 15.37 na 208 28.7 14.27 na 209 28.7 13.96 na 210 28.7 13.96 na 211 28.7 14.21 na 212 28.7 15.19 na 123 28.7 21.66 na 124 28.7 23.82 na 125 28.7 25.97 na 121 25.5 43.78 na 213 29.17 25.4 na 214 29.17 24.4 na 215 29.17 24.27 na 216 29.17 24.41 na 101 25.5 43.29 na 121A 25.5 44.45 na 116 25.5 44.65 na 117 25.0 49.49 na 118 25.0 49.5 na 119 25.0 49.54 na 120 25.0 49.96 na 180 25.5 46.08 na 181 11.0 53.2 na 8 11.0 53.42 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 5 BRESSI RANCH LOT 16 Date 9/5/06 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. 8A 11.0 54.98 na 9 11.0 55.04 na 102 27.75 43.8 na 103 27.75 43.93 na 104 27.75 . 43.95 na 105 27.75 44.05 na 106 27.75 44.16 na 107 27.75 44.18 na 108 27.75 44.3 na 109 27.75 44.38 na 110 27.75 44.43 na 111 25.0 47.34 na 112 25.0 47.35 na 113 25.0 47.6 na 114 25.0 47.99 na 115 25.0 50.23 na TRA 25.0 51.96 na Fl 11.0 58.76 na BRA 1.0 64.64 na A -3.0 66.46 na BF2 -3.0 66.96 na BF1 -3.0 70.32 na B -3.0 70.56 na 250.0 D -3.0 70.59 na E -3.0 70.79 na TEST -16.5 76.99 na The maximum velocity is 14.55 and it occurs in the pipe between nodes 121 and 213 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Hazen-Williams INDUSTRIAL FIRE SPRINKLER CO. Page 6 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S21 21.48 1.049 iT 5.0 0.080 14.713 K Factor = 5.60 to 120 0.0 5.000 -0.217 201 21.48 0.1486 0.0 5.080 0.755 Vel= 7.97 0.0 21.48 15.251 K Factor= 5.50 S22 20.70 1.049 IT 5.0 0.080 13.659 K Factor= 5.60 to 120 0.0 5.000 -0.217 202 20.7 0.1388 0.0 5.080 0.705 Vet = 7.68 0.0 20.70 14.147 K Factor= 5.50 S23 20.46 1.049 IT 5.0 0.080 13.353 K Factor = 5.60 to 120 0.0 5.000 -0.217 203 20.46 0.1358 0.0 5.080 0.690 Vet = 7.60 0.0 20.46 13.826 K Factor= 5.50 S24 20.46 1.049 IT 5.0 0.080 13.352 K Factor = 5.60 to 120 0.0 5.000 -0.217 204 20.46 0.1358 0.0 5.080 0.690 Vet = 7.60 0.0 20.46 13.825 K Factor= 5.50 S25 20.65 1.049 IT 5.0 0.080 13.592 K Factor= 5.60 to 120 0.0 5.000 -0.217 205 20.65 0.1382 0.0 5.080 0.702 Vet = 7.67 0.0 20.65 14.077 K Factor= 5.50 S26 21.34 1.049 IT 5.0 0.080 14.525 K Factor= 5.60 to 120 0.0 5.000 -0.217 206 21.34 0.1469 0.0 5.080 0.746 Vet= 7.92 0.0 21.34 15.054 K Factor= 5.50 S27 21.41 1.049 IT 5.0 0.080 14.617 K Factor = 5.60 to 120 0.0 5.000 0.0 207 21.41 0.1476 0.0 5.080 0.750 VeI= 7.95 0.0 21.41 15.367 KFactor= 5.46 S28 20.63 1.049 IT 5.0 0.080 13.574 K Factor = 5.60 to 120 0.0 5.000 0.0 208 20.63 0.1378 0.0 5.080 0.700 Vet = 7.66 0.0 20.63 14.274 K Factor= 5.46 S29 20.40 1.049 IT 5.0 0.080 13.272 K Factor = 5.60 to 120 0.0 5.000 0.0 209 20.4 0.1350 0.0 5.080 0.686 Vet = 7.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 7 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 20.40 13.958 K Factor= 5.46 S30 20.40 1.049 IT 5.0 0.080 13.270 K Factor = 5.60 to 120 0.0 5.000 0.0 210 20.4 0.1350 0.0 5.080 0.686 VeI= 7.57 0.0 20.40 13.956 K Factor= 5.46 S31 20.58 1.049 IT 5.0 0.080 13.512 K Factor =5.60 to 120 0.0 5.000 0.0 211 20.58 0.1372 0.0 5.080 0.697 VeI= 7.64 0.0 20.58 14.209 K Factor = 5.46 S32 21.28 1.049 IT 5.0 0.080 14.444 K Factor = 5.60 to 120 0.0 5.000 0.0 212 21.28 0.1461 0.0 5.080 0.742 VeI= 7.90 0.0 21.28 15.186 KFactor= 5.46 S33 27.55 1.049 iT 5.0 0.080 24.205 K Factor = 5.60 to 120 0.0 5.000 0.0 213 27.55 0.2354 0.0 5.080 1.196 Vel = 10.23 0.0 27.55 25.401 K Factor= 5.47 S34 27.00 1.049 IT 5.0 0.080 23.250 K Factor = 5.60 to 120 0.0 5.000 0.0 214 27.0 0.2268 0.0 5.080 1.152 Vel = 10.02 0.0 27.00 24.402 K Factor= 5.47 S35 26.93 1.049 IT 5.0 0.080 23.128 K Factor = 5.60 to 120 0.0 5.000 0.0 215 26.93 0.2256 0.0 5.080 1.146 Vel = 10.00 0.0 26.93 24.274 K Factor= 5.47 S36 27.01 1.049 IT 5.0 0.080 23.257 K Factor =5.60 to 120 0.0 5.000 0.0 216 27.01 0.2270 0.0 5.080 1.153 VeI= 10.03 0.0 27.01 24.410 K Factor= 5.47 138 15.96 1.38 4T 24.0 182.000 44.635 to 120 0.0 24.000 0.217 118 15.96 0.0225 0.0 206.000 4.645 Vel = 3.42 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 8 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 15.96 49.497 K Factor= 2.27 137 15.26 1.38 3E 9.0 189.000 44.592 to 120 5T 30.0 39.000 0.217 119 15.26 0.0208 0.0 228.000 4.731 Vel = 3.27 0.0 15.26 49.540 KFactor= 2.17 136 14.83 1.38 7E 21.0 225.250 44.547 to 120 3T 18.0 39.000 0.217 120 14.83 0.0197 0.0 264.250 5.199 VeI= 3.18 0.0 14.83 49.963 KFactor= 2.10 126 -63.96 1.38 2T 12.0 79.250 43.273 to 120 0.0 12.000 -1.191 201 -63.96 -0.2940 0.0 91.250 -26.831 Vel = 13.72 201 21.48 1.38 0.0 8.000 15.251 to 120 0.0 0.0 0.0 202 -42.48 -0.1380 0.0 8.000 -1.104 Vel = 9.11 202 20.69 1.38 0.0 8.000 14.147 to 120 0.0 0.0 0.0 203 -21.79 -0.0401 0.0 8.000 -0.321 Vel = 4.67 203 20.47 1.38 0.0 8.000 13.826 to 120 0.0 0.0 0.0 204 -1.32 -0.0001 0.0 8.000 -0.001 Vel = 0.28 204 20.46 1.38 0.0 8.000 13.825 to 120 0.0 0.0 0.0 205 19.14 0.0315 0.0 8.000 0.252 VeI= 4.11 205 20.65 1.38 0.0 8.000 14.077 to 120 0.0 0.0 0.0 206 39.79 0.1221 0.0 8.000 0.977 Vel = 8.54 206 21.34 1.38 0.0 8.000 15.054 to 120 0.0 0.0 0.0 127 61.13 0.2704 0.0 8.000 2.163 Vel= 13.11 127 0.0 1.38 0.0 8.000 17.217 to 120 0.0 0.0 0.0 128 61.13 0.2704 0.0 8.000 2.163 Vel = 13.11 128 0.0 1.38 0.0 8.000 19.380 to 120 0.0 0.0 0.0 129 61.13 0.2705 0.0 8.000 2.164 Vel= 13.11 129 0.0 1.38 0.0 8.000 21.544 to 120 0.0 0.0 0.0 130 61.13 0.2704 0.0 8.000 2.163 Vel= 13.11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 9 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 130 0.0 1.38 0.0 8.000 23.707 to 120 0.0 0.0 0.0 131 61.13 0.2704 0.0 8.000 2.163 Vel= 13.11 131 0.0 1.38 0.0 8.000 25.870 to 120 0.0 0.0 0.0 132 61.13 0.2704 0.0 8.000 2.163 VeI= 13.11 132 0.0 1.38 2T 12.0 54.250 28.033 to 120 0.0 12.000 1.408 112 61.13 0.2704 0.0 66.250 17.913 VeI= 13.11 0.0 61.13 47.354 KFactor= 8.88 122 -63.67 1.38 2T 12.0 79.250 43.355 to 120 0.0 12.000 -1.386 207 -63.67 -0.2915 0.0 91.250 -26.602 Vel = 13.66 207 21.41 1.38 0.0 8.000 15.367 to 120 0.0 0.0 0.0 208 -42.26 -0.1366 0.0 8.000 -1.093 Vel = 9.06 208 20.63 1.38 0.0 8.000 14.274 to 120 0.0 0.0 0.0 209 -21.63 -0.0395 0.0 8.000 -0.316 Vel = 4.64 209 20.41 1.38 0.0 8.000 13.958 to 120 0.0 0.0 0.0 210 -1.22 -0.0002 0.0 8.000 -0.002 Vel = 0.26 210 20.40 1.38 0.0 8.000 13.956 to 120 0.0 0.0 0.0 211 19.18 0.0316 0.0 8.000 0.253 VeI= 4.11 211 20.58 1.38 0.0 8.000 14.209 to 120 0.0 0.0 0.0 212 39.76 0.1221 0.0 8.000 0.977 Vel= 8.53 212 21.28 1.38 0.0 24.000 15.186 to 120 0.0 0.0 0.0 123 61.04 0.2697 0.0 24.000 6.472 VeI= 13.09 123 0.0 1.38 0.0 8.000 21.658 to 120 0.0 0.0 0.0 124 61.04 0.2698 0.0 8.000 2.158 VeI= 13.09 124 0.0 1.38 0.0 8.000 23.816 to 120 0.0 0.0 0.0 125 61.04 0.2698 0.0 8.000 2.158 Vel= 13.09 125 0.0 1.38 2T 12.0 62.250 25.974 to 120 0.0 12.000 1.602 113 61.04 0.2697 0.0 74.250 20.025 VeI= 13.09 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 10 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 61.04 47.601 KFactor= 8.85 121 -67.81 1.38 2T 12.0 39.250 43.778 to 120 0.0 12.000 -1.589 213 -67.81 -0.3276 0.0 51.250 -16.788 Vet = 14.55 213 27.55 1.38 0.0 8.000 25.401 to 120 0.0 0.0 0.0 214 -40.26 -0.1249 0.0 8.000 -0.999 Vet = 8.64 214 27.01 1.38 0.0 8.000 24.402 to 120 0.0 0.0 0.0 215 -13.25 -0.0160 0.0 8.000 -0.128 Vet = 2.84 215 26.93 1.38 0.0 8.000 24.274 to 120 0.0 0.0 0.0 216 13.68 0.0170 0.0 8.000 0.136 Vet = 2.93 216 27.00 1.38 3E 9.0 156.000 24.410 to 120 IT 6.0 15.000 1.806 114 40.68 0.1273 0.0 171.000 21.770 Vet= 8.73 0.0 40.68 47.986 KFactor= 5.87 101 -19.62 2.635 0.0 12.750 43.291 to 120 0.0 0.0 0.0 126 -19.62 -0.0014 0.0 12.750 -0.018 VeI= 1.15 126 63.96 2.635 0.0 12.750 43.273 to 120 0.0 0.0 0.0 122 44.34 0.0064 0.0 12.750 0.082 VeI= 2.61 122 63.67 2.635 0.0 12.750 43.355 to 120 0.0 0.0 0.0 121 108.01 0.0332 0.0 12.750 0.423 Vet = 6.35 121 67.81 2.635 0.0 8.250 43.778 to 120 0.0 0.0 0.0 121A 175.82 0.0818 0.0 8.250 0.675 Vet = 10.34 121A -114.52 2.635 0.0 8.000 44.453 to 120 0.0 0.0 0.0 136 61.3 0.0118 0.0 8.000 0.094 Vet = 3.61 136 -14.82 2.635 0.0 6.500 44.547 to 120 0.0 0.0 0.0 137 46.48 0.0069 0.0 6.500 0.045 Vel = 2.73 137 -15.26 2.635 0.0 12.750 44.592 to 120 0.0 0.0 0.0 138 31.22 0.0034 0.0 12.750 0.043 Vet= 1.84 138 -15.97 2.635 0.0 12.750 44.635 to 120 0.0 0.0 0.0 116 15.25 0.0009 0.0 12.750 0.011 Vet= 0.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 11 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 116 0.0 1.38 4E 12.0 187.000 44.646 to 120 4T 24.0 36.000 0.217 117 15.25 0.0207 0.0 223.000 4.623 VeI= 3.27 117 0.0 2.635 0.0 12.750 49.486 to 120 0.0 0.0 0.0 118 15.25 0.0009 0.0 12.750 0.011 VeI= 0.90 118 15.97 2.635 0.0 12.750 49.497 to 120 0.0 0.0 0.0 119 31.22 0.0034 0.0 12.750 0.043 VeI= 1.84 119 15.26 2.635 2E 16.474 44.250 49.540 to 120 0.0 16.474 0.0 120 46.48 0.0070 0.0 60.724 0.423 Vel = 2.73 120 14.82 2.635 IT 16.474 6.590 49.963 to 120 0.0 16.474 0.0 115 61.3 0.0117 0.0 23.064 0.269 VeI= 3.61 0.0 61.30 50.232 KFactor= 8.65 121A 114.51 2.635 2E 16.474 10.920 44.453 to 120 iT 16.474 32.948 0.0 180 114.51 0.0370 0.0 43.868 1.624 VeI= 6.74 180 0.0 2.635 IE 8.237 14.500 46.077 to 120 0.0 8.237 6.280 181 114.51 0.0370 0.0 22.737 0.841 Vel = 6.74 181 0.0 2.635 0.0 6.080 53.198 to 120 0.0 0.0 0.0 8 114.51 0.0372 0.0 6.080 0.226 Vel = 6.74 8 0.0 2.635 IT 16.474 25.500 53.424 to 120 0.0 16.474 0.0 8A 114.51 0.0370 0.0 41.974 1.553 VeI= 6.74 8A 0.0 2.635 0.0 1.670 54.977 to 120 0.0 0.0 0.0 9 114.51 0.0371 0.0 1.670 0.062 VeI= 6.74 9 0.0 3.26 2E 18.815 244.700 55.039 to 120 IT 20.159 38.974 0.0 Fl 114.51 0.0131 0.0 283.674 3.724 Vel = 4.40 0.0 114.51 58.763 KFactor= 14.94 101 19.62 1.61 2T 16.0 79.250 43.291 to 120 0.0 16.000 -0.974 102 19.62 0.0156 0.0 95.250 1.485 Vel = 3.09 102 0.0 1.61 0.0 8.000 43.802 to 120 0.0 0.0 0.0 103 19.62 0.0156 0.0 8.000 0.125 Vel = 3.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 inal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 12 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 103 0.0 1.61 0.0 1.540 43.927 to 120 0.0 0.0 0.0 104 19.62 0.0156 0.0 1.540 0.024 Vel = 3.09 104 0.0 1.61 0.0 6.450 43.951 to 120 0.0 0.0 0.0 105 19.62 0.0157 0.0 6.450 0.101 Vel = 3.09 105 0.0 1.61 0.0 7.200 44.052 to 120 0.0 0.0 0.0 106 19.62 0.0156 0.0 7.200 0.112 Vel = 3.09 106 0.0 1.61 0.0 0.790 44.164 to 120 0.0 0.0 0.0 107 19.62 0.0152 0.0 0.790 0.012 Vel = 3.09 107 0.0 1.61 0.0 8.000 44.176 to 120 0.0 0.0 0.0 108 19.62 0.0156 0.0 8.000 0.125 Vel = 3.09 108 0.0 1.61 0.0 4.870 44.301 to 120 0.0 0.0 0.0 109 19.62 0.0156 0.0 4.870 0.076 Vel = 3.09 109 0.0 1.61 0.0 3.120 44.377 to 120 0.0 0.0 0.0 110 19.62 0.0154 0.0 3.120 0.048 Vel= 3.09 110 0.0 1.61 2T 16.0 94.250 44.425 to 120 0.0 16.000 1.191 111 19.62 0.0156 0.0 110.250 1.720 VeI= 3.09 111 0.0 2.635 0.0 12.750 47.336 to 120 0.0 0.0 0.0 112 19.62 0.0014 0.0 12.750 0.018 Vel= 1.15 112 61.13 2.635 0.0 12.750 47.354 to 120 0.0 0.0 0.0 113 80.75 0.0194 0.0 12.750 0.247 Vel = 4.75 113 61.04 2.635 0.0 7.000 47.601 to 120 0.0 0.0 0.0 114 141.7.9 0.0550 0.0 7.000 0.385 Vel= 8.34 114 40.69 2.635 IT 16.474 9.160 47.986 to 120 0.0 16.474 0.0 115 182.48 0.0876 0.0 25.634 2.246 VeI= 10.74 115 61.30 3.26 1 9.408 23.040 50.232 to 120 0.0 9.408 0.0 TRA 243.78 0.0531 0.0 32.448 1.724 Vel = 9.37 TRA 0.0 3.26 0.0 14.000 51.956 to 120 0.0 0.0 6.063 Fl 243.78 0.0531 0.0 14.000 0.744 Vel = 9.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Einal Calculations - Standard INDUSTRIAL FIRE SPRINKLER CO. Page 13 BRESSI RANCH LOT 16 Date 9/5/06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn Fl 114.51 4.26 2E 26.334 13.000 58.763 to 120 1Z 13.167 39.501 4.331 BRA 358.29 0.0294 0.0 52.501 1.545 Vel = 8.07 BRA 0.0 6.16 1 20.084 4.000 64.639 to 140 0.0 20.084 1.732 A 358.29 0.0037 0.0 24.084 0.089 Vel = 3.86 A 0.0 6.09 2F 21.583 81.000 66.460 to 150 2E 43.166 64.749 0.0 BF2 358.29 0.0034 0.0 145.749 0.498 Vel = 3.95 BF2 0.0 6.16 2E 40.168 16.000 66.958 to 140 IT 43.037 83.205 3.000 * Fixed loss = 3 BFI 358.29 0.0037 0.0 99.205 0.364 Vel = 3.86 BFI 0.0 6.09 IG 4.625 20.000 70.322 to 150 1T 46.249 50.874 0.0 B 358.29 0.0034 0.0 70.874 0.242 Vel = 3.95 B 5.06 9.79 3G 20.242 512.000 70.564 Qa=250 to 150 1E 29.689 132.249 0.0 E 363.35 0.0003 IF 14.844 644.249 0.224 VeI= 1.55 IT 67.474 0.0 363.35 70.788 K Factor= 43.19 B 244.94 9.79 IE 29.689 133.000 70.564 to 150 0.0 29.688 0.0 D 244.94 0.0002 0.0 162.688 0.027 Vel = 1.04 D 0.0 9.79 6G 40.485 932.000 70.591 to 150 2E 59.378 241.559 0.0 E 244.94 0.0002 SF 74.222 1173.559 0.197 VeI= 1.04 IT 67.474 E 363.35 9.79 IE 29.689 272.000 70.788 to 150 IF 14.844 118.754 5.847 TEST 608.29 0.0009 IG 6.747 390.754 0.352 Vel = 2.59 IT 67.474 0.0 608.29 76.987 K Factor= 69.33 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary INDUSTRIAL FIRE SPRINKLER CO. Page 14 BRESSI RANCH LOT 16 Date 9/5/06 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length 126 201 79.250 132 112 54.250 122 207 79.250 125 113 62.250 121 213 39.250 216 114 156.000 Flow Pressure Pressure Required Required Differential Left 8.000 I 606.908 76.954 -0.033 Area Calculated I 608.293 76.987 0.000 Right 8.000 I 609.821 76.835 -0.152 Typical Distance Between Heads = 8.000 Split Point Used in Worst Area Peaked = S30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ;1 09 Zc AUTOMATIC SPRINKLERS FIRE PROTECTION PRODUCTS WTU I IT• k4 eled ~ cI: K5.6 Models V3801 and V3802 Adjustable Concealed Standard Spray Pendent OR EQUAL Standard and Quick Response . , . -t- ~~ z~';'_ - T'L p PRODUCT DESCRIPTION T) See Victaulic publication tOOl for details. This concealed, designer style sprinkler allows up to ½" (13 mm) adjustment to accommodate conceal- ment needs. The stan- dard design provides a consistent hemispherical spray pattern. The sepa- rate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard Nominal Orifice Size: ½" (13 mm) K-Factor: 5.6 Imp. (8,1 SI.") Nominal Thread Size: ½" NPT(l5mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solu- tion Bulb Nominal Diameter: Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon* tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS 530400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS 530200 Protective Cap: Polyethylene ACCESSORIES Installation Wrench: U Concealed: V38-4 or V38-5 Sprinkler Finishes: U Plain brass (only) Cover Finishes: U Chrome plated U White painted U Flat black U Custom painted A For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. *Teflon is a registered trademark of Du- pont Co. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic©victaulic.com e-mail: viccanadaictaulic.com e-mail: viceuroictaulic.be e-mail: vical©victaulic.com e-mail: vicap©Victaulic.com 2556 Rev.E 5,04 0 Registered Trademark of Victaulic 0 copyright 2004 Viclaulic Printed in U.S.A. APPROVALS/LISTINGS Nominal Approvals * K-Factor Orifice Size Imperial Deflector Model Inches/mm S.LA Response Type UL FM ULC NYC/MEAt CSFM § V3801 ½ 5.6 Standard Concealed Pendent 155-200 No 135-200 135-200 135-200 13 8,1 5 m bulb - 57 -93 5793 57 -93 V3802 1/2 5.6 Quick Concealed Pendent 135-200 155-200@ 135-200 135-200 135- 200 13 8,1 3 m bulb 5793 68-93 57-93 57-93 57-93 Listings and approval as of printing. A For K-Factor when pressure is measured in Bar, multiply S. I. units by 10.0. @ Recognized by FM as standard response only. f MEA #62-99-8. § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in table below. SPRINKLER - V3801, V3802 COVER - V38 Sprinkler Temperature - °F/°C Cover Temperature - °F/°c Sprinkler Victaulic Nominal Maximum Glass Victaulic Nominal Maximum Temperature Part Temperature Ambient Temp. Bulb Part Temperature Ambient Temp. Classification Identification Rating Allowed Color identification Rating Allowed Ordinary A 135 57 100 38 Orange A* 135 57 100 38 Ordinary C 15 13080 Red 68 Intermediate E 179 75 150 65 Yellow D :t:74 165 150 65 Intermediate F 1 65 Green A For use with Standard or Quick Response Concealed Sprinkler 135°F (57°C) or 155°F(68°C). tD For use with Standard or Quick Response Concealed Sprinkler 175°F (79°C) or 200°F (93°C). Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Custorn Covers require $150.00 minimum per custom cover; minimum 20 pieces. Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. The plastic shipping cap must be removed for the sprinkler to operate properly. If shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the fire protection system shall he considered out of service, the Authority Having Jurisdiction notified, and a tirewatch is suggested. Failure to do so may result in failure at sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number U K-Factor J Cover Finish D Style U Thread Size L Wrench Model Number Ci Temperature Rating Ci Quantity Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and toot protection. - • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. , • Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.50 -2 DIMENSIONS 2 1/i&(68mm) Max. Hole L.._23/8 (60 mm) Mm. Hole 25/16" (59 mm) 1/2 (38 mm) Typical Ceiling Tile MINIMUM EXTENSION '- Finished Surface 2 (51 mm) ½ (13 mm) Adjustment 31/4"(83 mm) _______ Cover Plate Finished Surface MAXIMUM EXTENSION Models V3801, V3802 (Drawings not to scale) AVAILABLE WRENCHES Recessed Concealed Pendent - V3801, V3802 V38-4 or V38-5 40.50 -3 r7T -' i75 ' DISTRIBUTION PATTERNS MODELS V3801, V3802 K5.6 STANDARD CONCEALED PENDENT DISTRIBUTION PATTERNS-TRAJECTORY ---- 8' -------- 2,4m -- 1,8m ---- 4, 1,2m D,6m 2' 6' 8' 10' 12' 14' 0,6 m 1,2 m 1,8 m 2,4 rn 3.0 m 3,7 m 4,3 m 7 psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as rriinirnurn sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly Instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.50 -4 Recessed Horizontal Sidewall w =~~ / \I!!... au ,•c ft V271r K5.6 Models V2709 and V2710 430 Standard Spray OR EQUAL Horizontal Sidewall and P Recessed Horizontal Sidewall Standard and Quick Response PRODUCT DESCRIPTION These Model V27, standard spray horizontal sidewall sprinklers are designed for standard or recessed instal- lation. The design provides V2709 a crescent-shaped water Standard V2710 discharge pattern for instal- Horizontal Sidewall lation along a wall or under a beam or ceiling. The design incorporates state- - of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, pre- cise operation. The die cast frame is more 09 streamlined and attractive 10 than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to 3/4" (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effec- tive in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. 1 TECHNICAL SPECIFICATIONS Models: V2709, V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall Nominal Orifice Size: 1/2" (13 mm) K-Factor: 5.6 Imp. (8,1 5.1/') Nominal Thread Size: ½" NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Horizontal Deflector: UNS C22000 Commercial bronze Bulb: Class with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 mm U Quick Response: 3,0 mm Load Screw: UNS C65 100 Low Silicon bronze Pip Cap: UNS C65 100 Low Sili- con bronze Seal: Teflon* tape Spring: Beryllium nickel Frame: Die cast brass 65-30 Lodgement Spring: UNS S30200 Stainless steel ACCESSORIES Installation Wrench: O Open End: V27 O Recessed: V38-3 Finishes: O Plain brass O Chrome plated 0 White painted** O Flat black painted** 0 Custom painted** O Lead** 155, 200, 286SR Only: 0 Wax O Wax over lead** For cabinets and other accesso- ries refer to separate sheet. ' For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. Teflon is a registered trademark of Dupont co. DL Listed for corrosion resistance in all configurations. (Exaggerated for clani)') VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-Vlc (1-800-742-5842) Phone: 416-675-5575 . Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 416-675-5565 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@victaulic.com e-mail: viccaxada@viclaulic.com e-mail: viceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com 2545 Rev.D 11/02 0 Registered Trademark of Victaulic 0 copyright 2002 Victaulic Printed in U.S.A. -1 1 APPROVALS/LISTINGS Nominal Approved Temperature Ratings F/c (1 K-Factor Orifice Size Imperial Deflector Model Inches/mm s.i.° Response Type UL FM@ ULC NYC/MEA? CSFM § V2709 1/2 5.6 Standard Horizontal Sidewall 135-360 135-360 135-360 135-360 135-360 57 182 182 57..7i? 57- 18 57-18? V2709 1/2 5.6 Standard Recessed HSW 135-200 135-200 135-200 135-200 135-200 H . Up to W Adjustment 33 5/.53 57 9/ 57.. 33 V2710 ½ 5.6 . Quick . Horizontal Sidewall 135-286 135-286 135-286 135-286 - 141 135-286 57 - 57 -14 57-141 V2710 1/2 5.6 Quick Recessed HSW 135-200 135-200 135-200 5/ . 93 135-200 135-200 13 Up to 1/2 Adjustment 57 95 57 93 57 93 V2710 ½ 5.6 Quick Recessed HSW 135-200 No 135-200 135-200 135-200 31. Up to WAdjustment 57 q - . 5? 57.91 S Listings and approval as of printing. 0 All are approved open, except for areas designated "No". @ Light Hazard only. ' For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. t MEA #62-99-E. § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55T) to those shown in adjacent table. Temperature - °FIc Nominal Maximum Sprinkler. Victaulic Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 Orange 33 Ordinary . C 155 i 100 38 Red Intermediate E 175 /9 150 Yellow Intermediate F 200 150 Green High J 286 141 225 - 137 Blue Extra High S K 360 182 300 115 Mauve - S M Open No Bulb S Standard response only. All are approved open, except for areas designated "No". - 150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: LI Sprinkler Model Number [3 K-Factor 0 Sprinkler Finish O Style []Thread Size LI Escutcheon Finish LI Temperature Rating 0 Quantity LI Wrench Model Number . Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. qF . Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 . Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40,11-2 DIMENSIONS 3" (89 mm) H2'Iu" (57 mm) 511el "u, (32mm) (8 mm) 11 mm) Standard HSW —V2709, V2710 (17 mm) 21%" " mm (56 mm) (43 mm) (27 mm) _______ Finished Ceiling Finished Ceiling 4-12(102-305mm) 4-12(102-305mm) Per NFPA Per NF - 2" (51 mm) 23N" (60 mm) 2W -- 2" (51 mm) 2W'(60 mm) ' Mm. Hole Max. Hole Mm. Hole Max. Hole Finished Surface —' Finished Surface - I— Typical Wall Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS ½' Adjustment Recessed —V2709, V2710 (Drawing not to scale) (24 mm) 21%" -4--- e/o" (14 mm) %e- (56 mm) (37 mm) (33 mm) Finished Ceiling Finished Ceiling - 12"(102305 mm) 4-12"(1 mm) Per NFPA Pe 72Mmm) 2%'(60 mm) Max. Hole I 2' (51 mm) 2W (60 mm) Max. Hole ole (75 mm) Min. Hole Finished Surface —' —1 I— Typical Wall Finished Surface __J Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS Y4" Adjustment Recessed —V2709, V2710 (Drawing not to scale) AVAILABLE WRENCHES V38-3 Recessed V27 Open End No escutcheon With escutcheon 40.11-3 DISTRIBUTION PATTERNS MODELS V2709, V2710 K5.6 STANDARD HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - TRAJECTORY 10' co-i- 3,0 m 8' 2,4 m 6' 1,8 m 4, 1,2 m 2' 0,6 m 0 7psi 48 kPa 15 psi 103 kPa 30 psi ------ 207 kPa 0,6 m 1,2 m 1,8 in 2,4 m 3,0 m 33 rn 43 m 4.9w 5,5 m 6,1 m 63 m 7,3 m 7,9 m MODELS V2709, V2110 K5.6 STANDARD HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - PLAN VIEW 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0,6 m 1,2 m 1,8 m 2,4 m 3.0 m 3.7 m 43 m 4,9 m 5.5 m 6.1 m 63 m 7.3 m 7.9 m 8,5 m IIIIIIItiIL NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War- ranties. '1 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.11-4 2' 0,6 n 4, 1,2 n 6' 1,8 n 8' 2,4 n 10' 3.0 n 12' 3.7 ii 14' 4.3 n 16' 4,9 ri 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa M M, INI X/_ CtauIic® OR EQUAL V27, K2.8 Models V2701, V2702, V2705 and V2706 Standard Spray Upright, Pendent or Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27, K2.8 orifice standard spray sprinklers are designed to produce a hemispherical IV spray pattern for use in light hazard occupancies which require minimal water discharge, such as Recessed Pendent bathrooms, closets and other small area applica- tions. The design incorpo- ULC rates state-of-the-art, heat .L responsive, frangible glass bulb design (standard or quick response) for prompt, ,,. precise operation. Pendent V2701 L. - V2]02 Request Victaulic pcblceUen 1001 In, detmie Upright The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up t0 3/4" (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effec- tive in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. rLI TECHNICAL SPECIFICATIONS (Exaggerated for c/any) Models: V2701, V2702, V2705, V2706 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: %" (10 mm) K-Factor: 2.8 Imp. (4,0 S.I.fu) Nominal Thread Size: 1/2cNPT(15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS 022000 Pendent Deflector: Bronze per UNS 022000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Bushing: Brass per UNS 036000 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: 0 Open End: V27 0 Recessed: V38, V38-3 LI Socket: V27 Finishes: O Plain brass C3 Chrome plated LI White painted** 0 Flat black painted** D Custom painted** 0 Lead 155, 200, 2865R Only: Wax Wax over lead For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. " For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. * Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance in all configurations. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8811 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-tTtail:pickvic@victaulic.com e-mail: viccanada@vicBulic.com e-mail: viceuro@vict.aulic.be e-mail: vical@victaulic.com e-mail: vicap@viclaulic.com 2543 Rev,O 10/03 0 Registered Trademark of Victaulic 0 Copyright 2003 Victaulic Printed in U.S.A. . •.- APPROVALS/LISTINGS Nominal Approved Temperature Ratings F/°C K-Factor Orifice Size Imperial Deflector Model Inches/mm S.LA Response Type UL FM ULC NYC/MEAt CSFM § V2701 2.8 Standard Upright 135-360 135-360 135-360 135-360 135-360 10 40 57-182 5]- 182 57-182 57.182 57-182 V2705 3/8 2.8 Standard Pendent 135-360 No 135-360 135-360 135-360 10 4.0 57-182 57-182 57-182 57-182 V2705 3/8 2.8 Standard Recessed Pendent 135- 360 No 135-360 135-360 135-360 10 4.0 Up to 3/4' Adjustment 57-182 57-182 57-182 57-182 V2702 2.8 Quick Upright 135-286 135-286 135-286 135-286 135-286 10 4,0 57-141 57- 141 57 -141 57-141 57-141 V2706 3/8 2.8 Quick Pendent 135-286 No 135-286 135-286 135-286 10 4,0 57-141 57 -141 57-141 57-141 V2706 3/8 Quick 2.8 2.8 Recessed Pendent 135-200 135-200 135-200 135-200 10 4,0 Up toW Adjustment 57.93 57.93 57.93 Listings and approval as of printing. 13 All are approved open, except for areas designated "No". " For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. F MEA462-99-E. §CSFM#7690.0531:112 -.- ----r _i RATINGS All glass bulbs are rated for temperatures from -67°F (-55T) up to those shown in adjacent table. Temperature - °F/C Sprinkler Victaulic Glass Nominal Maximum Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary c 155 00 1 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 150 93 65 Green High J 286 141 225 - 107 Blue Extra High K 360 182 300 149 Mauve - M Open = No Bulb Standard response only. All are approved open, except for areas designated "No". - 150/65 if was coated. ORDERING INFORMATION Please specify the following when ordering: LI Sprinkler Model Number LI K-Factor LI Sprinkler Finish LI Style LI Thread Size 0 Escutcheon Finish LI Temperature Rating LI Quantity LI Wrench Model Number - Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. , F Installation rules, especially those governing obstnjction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. ailure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.40 -2 DIMENSIONS 1 7/1 o' (37 mm) 2W 1W (60 mm) 1W (41 mm) 23L (41 mm) N (60mm) (25mm) Standard Pendent - V2705, V2706 Standard Upright - V2701, V2702 21/i'(60 mm) Max. Hole 2 (51 mm) Min. Hole (24m) / 7//, Ceiling Tile :t Typical Finished surface MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION Y4' Adjustment Recessed - V2705, V2706 (Drawing not to scale) L. AVAILABLE WRENCHES V27 Socket V38orV38-3 Recessed V27 Open End V2705, V2706 Pendent / / / V2705, V2706 Recessed Pendent V2701, V2702 Upright 40.40 -3 uiui•iiii•i••• UUUU•UUNU•UU• ui•uiiii 0 7psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa DISTRIBUTION PATTERNS MODELS V2705, V2706 K2.8 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS -TRAJECTORY 10' 3.0 m 8' - 2,4 m 6' - 1.8 m MEMEMENEEMENNE MENMEEMENMENNE MENNEEMEEMONEE NOMMOMMEEMEMEN ENEEMEEMENEENE NEENEENEWEREEN MENEEMENEEMENN uuu•uuu• MENEEMEMENEENE p., 4' - 1,2m 2' - 0,6 m 0 7psi 48 kPa 15 psi 103 kPa 30 psi ------ 207 kPa 2' 4' 6' 8' 10' 12' 14' 0.6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m MODELS V2701, V2702 K2.8 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 2' 4' 6' 8' 10' 12' 14' 0,6 m1,2 m1,8 m 2,4 m 3,0 m 3,7 m 4,3 m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.40 -4 April 10, 2006 NIKJNG4 @ Sprinkler 54 a MIRAGE® QUIRESPONSE CONCEALE1ENDENT SPRINKLER VK462 AND HP SPRINKLER V14631(K5.6) - -. - .I_•• • _._ - ,---:— -. I.T -17 Viking Mirage:. Concealed Sprinkler Installed in Acoustical Ceiling 1. PRODUCT NAME Viking Mirage® Quick Response Con- cealed Pendent Sprinkler VK462t and HP Sprinkler VK463t (K5.6) Sprinkler Base Part No. 13503A or HP Sprinkler Base Part No. 13667A Cover Plate Base Part No. 13504 or Cover Plate Base Part No. 13642 (large diameter) Patents Pending t The Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. Available since 2006. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 USA Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com PRODUCT DESCRIPTION Viking Mirage® Quick Response Con- cealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceil- ing is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to 1/2" (12,7 mm) of vertical adjust- ment. The two-piece design allows instal- lation and testing of the sprinkler prior to installation of the cover plate. The "push on", "thread-off' design of the concealed cover plate assembly allows easy instal- lation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allow- ing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. During fire conditions, when the temper- Sprinkler and Adapter Assembly [1 Cover Assembly (Base P/N 13504 shown) ature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat- sensitive liquid in the glass bulb to expand and the bulb to shatter, re- leasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pat- tern to extinguish or control the fire. NOTE: Must be installed in neutral or negative pressure plenums only. TECHNICAL DATA LISTINGS AND APPROVALS Refer to the Approval Chart on pg 54 b. Glass-bulb fluid temperature rated to -65 °F (-55 °C). Thread Size: %" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (8,1 metric*) * Metric K-Factor shown is for use when pres- sure is measured in kPa. When pressure is measured in BAR, multiply the metric K- Factor shown by 10.0. Mm. Operating Pressure: 7 psi (48,3 kPa) RATED WATER WORKING PRESSURE Sprinkler VK463 is rated for use with water working pressures up to 250 psi (1 724 kPa) for high-pressure systems. High-pressure (HP) sprin- klers can be identified by the number "250" on the deflector. Sprinkler VK462 is rated to a maxi- mum 175 psi (1 207 kPa) wwp Factory tested hydrostatically to 500 psi (3 448 kPa). Testing: U.S.A. Patent No. 4,831,870 Available Cover Plate Vertical Adjust- ment: 1/2" (12 mm) maximum Requires a 2-1/4" (57,2 mm) diameter opening in the ceiling. Cover Plate Assembly Temp. Ratings: A 135 °F (57 °C) cover for use with 155 °F (68 °C) temp. rated sprinkler only. B. 165 OF (74 °C) cover for use with 175 OF (79 °C) and 200 °F (93 °C) temperature rated sprinklers only. SPRINKLER MATERIALS /->' Sprinkler Body: Brass UNS-C84400 Deflector: Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30300 Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS- G10080, Finish: Clear Chromate over Zinc Plating COVER ASSEMBLY MATERIALS Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic NOTE: The 135 OF cover has an orange label; the 165 OF cover has a white label. AVAILABLE COVER FINISHES Polished Chrome, Painted' White (No. 1004)2, Painted' Ivory (No. 1634)2, and Painted' Black (No. 1007)2 1 Painted finish consists of Polyester Baked Enamel. 2 SherwinWIIliams® Color AnswersTM Interior Color Number. ORDERING INSTRUCTIONS Viking Mirage® Quick Response Con- cealed Pendent Sprinklers and Cover Plate Assemblies must be ordered sep- arately. Refer to: 1. Sprinkler (includes sprinkler and adap- ter pre-assembled with a protective plastic cap covering the unit): Base Part No. 13503A or HP Base Part No. 13667A Specify sprinkler temperature rating. 2. Cover Plate Assembly: Base P/N 13504 (2-3/4" diameter) or Base P/N 13642 (3-5/16" diameter) Specify cover finish and temp. rating. ACCESSORIES (order separately) Sprinkler Cabinet: Part No. 01731A Capacity: five (5) sprinklers Available since 1971. Concealed Sprinkler Wrenches: Heavy Duty Part No. 14047W/B Available since 2006, or Light Duty Part No. 14031*** Available since 2006. **Requires a Y2" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Note: Units of measure in parentheses may be approximations. Replaces page 54 a-b, dated Feb. 3, 2006 (added HP Sprinkler Form No. F_i 03005 VK463). Refer to technical data page QRI-2 for general care, installation, and maintenance information. 41 / Sprinkler 54 b April 10, 2006 MIRAGE@ QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Plate Assembly Bulb Classification Temperature Rating' Ceiling Temperature Cover Assembly (Required) Base Part Numbers3 Color Ordinary 155°F (68 °C) 100°F (38 °C) 135°F (57 °C) 13504 (2-3/4" diameter) or 13642 (3-5/16' diameter) Red Intermediate 175°F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200°F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Approval Chart -5rnK1 Tene'st eReln1 , C'. Mirage® Quick Response Concealed Pendent Sprinklers AWI* O'eI -la w Fin i KEY Sprinkler NPT Thread Nominal Maximum Overall Length Listings and A rovals4 g Base Part SIN Size K-Factor Water Working (Sprinkler Body) Number Pressure Inch mm U.S. metric5 Inch mm cULus6 FM NYC VdS LPCB 13503A VK462 1/2 15 5 8,1 175 psi (1 207 kPa) 2-3/16 56 AWl, BX1 -- 13667A VK463 1/2 15 5.6 8,1 250 psi (1 724 kPa)7 2-3/16 56 AWl, BX1 -- Sprinkler Temperature Ratings Cover Plate Assembly Temp. Ratings Finishes of the Cover Plate Assembly A - 155 °F (68 °C) W- 135°F (57 °C) 1 - Polished Chrome, Painted White, Painted B - 175 °F (79 °C) and 200 °F (93 °C) x - 165 °F (74 °C) Ivory, or Painted Black Footnotes 1 The temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Base part number is shown. For complete part number, refer to Viking's current price list schedule. 4 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Metric K-factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factor by 10.0. 6 Listed by Underwriters Laboratories, Inc. for use in the U.S. and Canada. 7 The Water Working Pressure rating is stamped on the deflector. A 2-1/4" (57,2 mm) diameter opening is required in the ceiling 0 1; t111 -,.A A...4.. s)}JIIIITUCI CI IU ruop ci - - Assembly (Protective cap ______ is removed for installation ____________ by using \Mench 14031**) **A '/z" ratchet is required Sprinkler Wrench (not available from Viking). /1 (Part No. 14047W/B** Step 1: Carefully slide the is shown) Step 2: Carefully press the wrench wrench sideways around the deflector and pins. f upward and turn slightly to ensure Figure 1 engagement with sprinkler wrench flats. (15 mm NPT ,•. 2-3/4!'(70 mm) I NOTE: Upon sprinkler activation, the deflector *j--5 16" (84,1 m) descends to approximately 13/16" (20,6 mm) Figure 2 below the sprinkler body. Replaces page 54 a-b, dated Feb. 3, 2006 (added HP Sprinkler VK463). Refer to technical Form No. F_103005 data page QRI-2 for general care, installation, and maintenance information. Z ic tauI.c V389 K5.6 if Models V3801 and V3802 OR Adjustable Concealed EQUAL rjfr Standard Spray Pendent Standard and Quick Response PRODUCT DESCRIPTION This concealed, designer t'H 71 c.nr,r,l.rl Y ,mllr,it, 1 71 1- . C O1JS.L1.L1UL Oj..L'_JVVO PLAd ½ (13 mm) adjustment to accommodate conceal- ment needs. The stan- dard" design provides a nedwt."rnt hwrntnhwrir.ed quick response) for prompt, precise operation. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kier, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. Spray pattern. The sepa- V3801 rate two-piece mounting V3802 cup/cover plate, allows easy See Victaulic installation and testing publication 10.01 prior to ceiling installation. for details. It also permits removal of suspended ceiling panels without system shutdown. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or TECHNICAL SPECIFICATIONS Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard Nominal Orifice Size: ½ (13 mm) K-Factor: 5.6 Imp. (8.1 SI!') Nominal Thread Size: ½' NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: LI Standard: 5,0 mm LI Quick Response: 3,0mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS 065100 Spring: Stainless steel per UNS S30100 Seal: Teflon* tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS 026000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene ACCESSORIES Installation Wrench: LI Concealed: V38-4 or V38-5 Sprinkler Finishes: LI Plain brass (only) Cover Finishes: LI Chrome plated LI White painted LI Flat black LI Custom painted A For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. "Teflon is a registered trademark of Du- pont Co. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvicvictaulic.com e-mail: viccanadavictaulic.com e-mail: viceuro©victaulic.be e-mail: vicaliviclaulic.com e-mail: vicap©viclaulic.com 2558 Rov.E 5104 0 Registered Trademark of Viciaslic © Copyright 2004 Viciaulic Printed in U.S.A. ,1 APPROVALS/LISTINGS Nominal Approvals K-Factor Orifice Size Imperial Deflector Model Inches/mm SiA Response Type UL FM ULC NYC/MEAt CSFM § V3801 ½ 5.6 Standard Concealed Pendent 155-200 No 135-200 135-200 135-200 13 8,1 5 m bulb - 5793 57-93 V3802 ½ 5,6 Quick Concealed Pendent 135-200 155-200@ 135-200 135-200 135-200 13 8,1 3mm bulb 5793 68-93 57-93 57-93 57-93 Listings and approval as of printing, A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. @ Recognized by FM as standard response only. f MEA#62-99-E. §CSFM #7690-0531:112 ir:;6 I RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in table below, SPRINKLER - V3801, V3802 COVER - V38 Sprinkler Temperature - °F/°C Cover Temperature - OFPC Sprinkler Victaulic Nominal Maximum Glass Victaulic Nominal Maximum Temperature Part Temperature Ambient Temp. Bulb Part Temperature Ambient Temp. Classification Identification Rating Allowed Color Identification Rating Allowed Ordinary A 135 57 100 38 Orange A* 135 57 100 38 Ordinary C 155 100 Red . 68 38 Intermediate E 175 150 79 65 Yellow 0 165 74 150 65 Intermediate F 200 150 Green A For use with Standard or Quick Response Concealed Sprinkler 135°F (57°C) or 155°F(68°C). tD For use with Standard or Quick Response Concealed Sprinkler 175°F (79°C) or 200°F (93°C). Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Custom Covets require $150.00 minimum per custom cover: minimum 200 pieces. Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. The plastic shipping cap must be removed for the sprinkler to operate properly. If shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the lire protection system shalt be considered out 01 service, the Authority Having Jurisdiction notified, and a firewatch is suggested. Failure to do so may result in failure of sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Cover Finish U Style U Thread Size U Wrench Model Number U Temperature Rating U Quantity Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and loot protection. qT - Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. , • Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. It you need additional copies of this publication, or if you have any questions about the sate installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559.3300. 40.50 -2 r• DIMENSIONS 211/16 (68 mm) Max. Hole 8(60mm) Min. Hole 2/1 (59 mm) 11/2 (38 mm) Typical Ceiling Tile 4 MINIMUM EXTENSION Finished Surface 3/1€ (80 mm) 213/16 (71 mm) 2" (51 mm) ½ (13 mm) Adjustment Typical Ceiling Tile 31/4' (83 mm) Cover Plate Finished Surface MAXIMUM EXTENSION Models V3801 V3802 (Drawings not to scale) Recessed Concealed Pendent - V3801, V3802 I V38-4 or V38-5 40-50 -3 I DISTRIBUTION PATTERNS MODELS V3801, V3802 K5.6 STANDARD CONCEALED PENDENT DISTRIBUTION PATTERNS -TRAJECTORY ----------------- 8' 2,4m 6' 1,8m D,6m \\j 2' 4' 6' 8' 10' 12' 14 0,6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m 7psi - 48 kPa 15 psi 103 kPa 30 psi ------ 207 ilDa NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Coda or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. - All patterns are symmetrical to the centerline of the wateiway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products lobe installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.50 -4