HomeMy WebLinkAbout2605 CARLSBAD BLVD; ; FA120040; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120040 Job Address: 2605 CARLSBAD BL Status: ISSUED Permit Type: FALARM Applied 9/28/2012 Parcel No: 2030410200 Approved: 9/28/2012 Lot #: 0 Reference No.: Issued: 9/28/2012 PC #: Inspector: Project Title: ARMY NAVY ACADEMY REPLACE SINGLE STATION SMOKE AND HEAT DETECTORS WITH ADDRESSABLE Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 619-596-9950 Owner: ARMY&NAVY ACADEMY CARLSBAD CALIFORNIA P 0 BOX 3000 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 396 0 396 0 I (indaihhhh l September 25, 2012 - Electronics I 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8850 SUBMITTAL SHEET PROJECT: Army & Navy Academy Infirm, Fegan, Dining Hall #1511 2605 Carlsbad Blvd. - Carlsbad, CA 92008 ArPFROVwD ----.-----.. r'PrNT EQUIPMENT FIRE ALARM ITEM QTY DESCRIPTION MODEL NO. DATA SHEET ANALOG PHOTOELECTRIC SMOKE DETECTOR 1 15 SFM#7272-1703 :012 1 ASD-PL2F FCI PLUG-IN BASE, FLANGED, 6.2 INCH DIAMETER SYSTEM 2 41 SFM #7300-1653:0109 B210-LP SENSOR ANALOG HEAT DETECTOR 190 DEGREE 3 26 SFM#7270-1703:0115 ATD-RL2F FCI EXTERIOR HEAT DETECTOR 4 1 SFM: 7270-0021:0001 302-ET-135 FCI ADDRESSABLE MONITOR MODULE 5 1 SFM #7300-1703:0102 AMM-2F FCI 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER 6 2K LIMITED - OVERALL JACKETED - FIRE PROTECTIVE D162F ADL SIGNALING CABLE 7 8 9 10 11 12 13 14 15 C 0 Velociti® Series ASB=PL2F, ASD-PTL2F and ASImPL21`1 z:!GameweH - FIRE CONTROL ____ INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCl analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Ordering Information Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Analog, Addressable Photoelectronic Smoke Sensor ASD-PL2F/ASD-PTL2F ASD-PL2FR Features Sleek, low-profile design Visual rotary, decimal switch addressing (01-159) Built-in functional test switch activated by an external magnet Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm* Optional relay, isolator, or sounder bases Low standby current Analog addressable communication Stable communication technique with noise immunity Optional remote, single-gang LED Indicator (RA400Z) Compatible with Gamewell-FCl analog addressable panels Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. An ISO 9001-2000 Company SIGNAUNG @<S> MEA LISTED APPROVED Approved S1913 3023594 219-02-E Vol.VI 7272-1703:121 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA• Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell.FCI for their use. ©2Ol0by Honeywell lntemahonalInc. All rights reserved. www.gamewell-fci.com . 9020-0617 Rev. F-I page 1 of 2 1 Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: 4.0" (10.2 cm) square box 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box Single-gang box (except relay or isolator bases) With B200SR base, mounted on a 4.0" (10.2 cm) square box With B224RB or B224B1 base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications Size: 2.1" (5.1 cm) high x4.1" (10.4 cm) diameter installed in the B501 base, 6.1" (15.5 cm) diameter installed in the ADB-FL base. Shipping Weight: 5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32° F to 120° F (0°C to 49° C) ASD-PTL2F: 320 Fto 100° F(0°Cto 38° C) UL®Listed Velocity Range: 0-4000 ft/mm. (1,219.2 rn/mm.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings: Fixed-temperature setpoint 135° F (57° C) Electrical Specifications Voltage Range: 15-32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (one communication every 5 seconds with LED enabled) Maximum Alarm Current: .0065 A © 24 VDC (LED) lit). Bases and Options ADB-FL 6.1" (15.5 cm) diameter B200SR 6.875" (17.46 cm) Base Diameter 2.0" (5.08 cm) Base Height B224RB Relay Base Screw terminals: Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.OA @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" x 1.2" (15.7 x 3.0 cm) Maximum: 25 devices between isolator bases. RA400Z Remote alarm indicator, LED. BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. H page 2 of 2 www.gamewell-fci.com 200 Series Mounting Base Options System Sensor mounting bases and kits provide a variety of installation options for detectors in any application. Features To meet local code and application requirements, Bases enable quick and secure detector plug-in System Sensor offers relay, isolator, and sounder base options for 200 Series detectors. Relay bases provide one form C contact relay SEMS screws provide easy wiring connection for control of auxiliary functions, such as door closure and elevator Support for 12-24 AWG provides installation flexibility recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. 1 Multiple accessory options provide mounting flexibility Sounder bases are available in a combination temporal 3 and Sounder bases are compliant with UL 464 and UL 268 continuous tone model (B200SR) or an addressable model (13200S) that can be activated by the fire alarm control panel based on the event.t 200 Series Bases provide a variety of mounting options to meet your installation challenges. Bases come in flanged or flangless versions for mounting to a variety of junction boxes. See the 200 Series Junction Box Selection Guide on the next page for junction box options. Surface mounting boxes are also available. Agency Listings Model Listings B501 UL, ULC,* FM, CSFM B21OLP UL, ULC, FM, CSFM B200S UL, ULC, FM, CSFM B200SR UL, ULC, FM, CSFM . B224R8 UL, ULC, FM, CSFM B224B1 FM, UL, ULC, CSFM tConsult your fire alarm control panel manufacturer for compatibility * For ULC-listed products, add 'A" to the model number (e.g., B501 A). with the addressable model of the sounder base. Specifications - 200 Series Bases . li -'r!1ITTh ]I1.. Diameter B501: 4.1 (104 mm); B21OLP: 6.1(155 mm); B224B1, B224RB, B200SR, B200S: 6.875(175 mm) Wire Gauge B224B1, B224RB, B200SR, B200S, B21OLP, B501: 24 to 12 AWG Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Humidity Range 10% to 93% RH non-condensing R 4'Zl I PPZl ii Angoril amTr Operating Voltage 15 to 32 VDC (powered by SLC) External Supply Voltage 16 to 33 VDC (VFWR) Standby Current 170/450 pA max. Standby Current 500 pA max. Set Time (113224RB only) Short Delay: 60 to 100 msec Lona Delay: 6 to 10 sec Reset Time (13224RB only) 20 msec max. Relay Characteristics 2 coil latching relay Sound Output Greater than 90 dBA measured in anechoic (13224RB only) 1 Form C contact room at 10 feet, 24 volts. 85 dBA minimum UL/ULC Rating: in UL reverberant room 0.5 A @ 125 VAC Alarm Current 35 mA max. 0.9A@ 125 VDC 3A@3OVDC 200 Series Junction Box Selection Guide nt'irTn B501 No Yes No No Yes Yes Yes Yes No B21OLP Yes Yes Yes Yes Yes No No Yes No 8224RB Yes Yes Yes Yes Yes No No Yes No B224B1 Yes Yes Yes Yes Yes No No Yes No B200SR/B200S Yes Yest Yes Yes Yest No No Yes No * with 3.0 mud ring S tB200SA is not compatitble with this 200 Series junction box Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information, 200 Series Bases B200S Addressable Sounder Base Product Overview B501* 4" Flangeless Mounting Base B501 BP* 4 Flangeless Mounting Base Bulk Pack B21OLP* 6" Flanged Mounting Base B21OLPBP* 6" Flanged Mounting Base Bulk Pack B200SR* Standard Sounder Base (Compatible with B501BH Series) B200S* Intelligent Addressable Sounder Base B224RB* Relay Base B224B1* Isolator Base 200 Series Accessories SMB600 Surface Mounting Kit (flanged) F110 Accessory Flange Ring for 6" Base F110BP Accessory Flange Ring for 6" Base Bulk Pack F210 Accessory New Smaller Flange Ring for 6 Base RA100Z* Remote LED Annunciator M02-04-01 Detector Test Magnet M02-09-00 Test Magnet with Telescoping Handle XR2B Detector Removal Tool (T55-127-000 included) XP-4 Extension Pole for XR2B (5 to 15 ft.) T55-127-000 Detector Removal Head BCK-200B Black Detector Kit WCK-200B White Detector Kit * Add "A" to model number for ULC-listed product (e.g., B501 A) When used with compatible fire alarm control panels, the B200S sounder base provides unmatched flexibility to configure the output to various events. When combined with System Sensor SpectrAlert® Advance notification appliances, the B200S can serve as a UL464 compliant component of the general evacuation signaling, improving aesthetics and reducing system costs. Features: Simple addressing scheme - base adopts the same address as attached sensor Synchronizable with SpectrAlert Advance notification appliances Four standard tone patterns at two selectable volumes Custom tone capability Support for Temporal-4 CO annunciation 3825 Ohio Avenue • St. Charles, IL 60174 System Sensor. TEM Phone 800-SENSOR2 • Fax: 630-377-6495 Prsdut specifications subject to change without notice. huh systemsensor.com or current product information, including the latest version of this data sheet. www.systemsensor.com CMDS00601 • 6/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - O LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 13401, B401 13, B401 R, B401 BR, B401 BR-750, B401 R-750, 1340213, 13404B, 1340413T, 1340613, 13501, 13501B, 14506587-002, BSOIBH, 1350113HT, 13401131-1, B110LP, 13110RLP, B11ORLP750, BI12LP, BI14LP, B114LPBT, 131161-P and B210LPdet4orbases. Refer to listee's data sheet for detailed product description and operational corii ratio is. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 10 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 9 Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division ATD-L2F Features Sleek, low-profile design Visual rotary switch addressing Built-in functional test switch activated by an external magnet Bicolor LEDs flash green whenever the sensor is addressed, and light steadily red on alarm* Optional relay, isolator, or sounder bases Low standby current Addressable communication Stable communication technique with noise immunity Optional remote, single-gang LED accessory (RA-400Z) Suitable for installation in ducts Note: *only the red LED is operative in panels that do not operate in VelocitiTM mode. An ISO 9000-2000 Company SIGNALING @<~> MEA LISTED APPROVED Approved -- S2332 3023594 21902-0 VoI.',n 07270-0694256 Gamewell w FIRE CONTROL L-JI Lg.J INSTRUMENTS by Honeywell VeJOCIJITM Series ATD-L2F, ATD-RL2F and ATD-HL2F Description Addressable Therhial Sensor The Gamewell-FCI VelocitiTM Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 1350F/570C fixed- temperature (ATD-L2F). The ATD-RL2F provides a combi- nation 150/minute rate-of-rise with 135° fixed thermal detection that is included in a low-profile package. The ATD-HL2F provides fixed high-temperature detection at 190°F/880C. These thermal sensors provide cost-effec- tive, addressable property protection in a variety of appli- cations. . The VelocitiTM Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The VelocitiTM Series uses a communication pro- tocol that substantially increases the speed of communica- tion between the sensors and Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. Ordering Information Model Description ATD-L2F Addressable thermal sensor, fixed, 135° F ATD-RL2F Addressable thermal sensor, combination fixed,135° F and 15°/minute rate-of-rise. ATD-HL2F Addressable thermal sensor, fixed, 190° F Velociti°' is a trademark and E3 Series® is a registered trademark of Honeywell International Inc. S UL® is a registered trademark of Underwriters Laboratories Inc. GAMEWELL-FCI - 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to Change without notice. No responsibility is assumed by GamewelFCl for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0620 Rev. C2 page 1 of 2 . Installation ATD plug-in sensors use a separate base to simplify instal- lation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: 4.0" (10.2 cm) square box. 3.5° (8.9 cm) or 4.0(10.2cm) octagonal box. Single-gang box (except relay or isolator base). With B501 BH or B501 BHT base, use a 4.0(10.2cm) square box. With B224RB or B224B1 base, use a 3.5 (8.9 cm) octagonal box, or a 4.0(10.2cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring. Specifications Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in ADB-FLF base .Shipping Weight: 4.8 oz. (137 g) Operating Temperature: ATD-L2F or ATD-RL2F ATD-HL2 Sensor Spacing: Relative Humidity: ATD-L2F ATD-RL2F ATD-HL2F Electrical Specifications Voltage Range: 15 32 volts DC peak Standby Current: 200 mA @ 24 VDC (without communication) max. avg.) 300 pA @ 24 VDC (one communication every 5 seconds with LED enabled) LED Current (max.) 6.5 mA @ 24 VDC (LED lit) Voltage Range 15-32 volts DC peak Bases and Options ADB-FLF 6.1" (15.5 cm) diameter standard base B501 4.1(10.4cm) diameter flangeless base B5O1BH or B501 BHT Sounder base assembly (13501 BHT produces a Temporal Pattern) Includes B501 base B224RB Relay Base Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.OA @ 30 VDC resistive 0.3A @ 110 VDC inductive 1.0 A @ 30 VDC inductive B224RB Relay Base Dimensions: 6.2": (15.7 cm) x 1.2" (3.0 cm) B22461 Isolator Base Dimensions: 6.2(15.7cm) x 1.2" (3.0 cm) Maximum 25 devices between isolator bases RA-400Z Remote alarm indicator, LED BCK-200 Black detector covers (box of 10) -4° F to 1000 F (-20° C to 38°C) _40 F to 150°F (-20 C to 66°C) UL® approved for 50 ft. (15.2 m) center to center FM approved for 25 x 25 ft. (7.6 x 7.6 m) spacing 10 - 93% (non-condensing) Fixed-temperature setpoint 135°F (57°C) Combination 135° F fixed temperature and 15° (8.30c) per minute rate-of-rise0 Fixed-temperature setpoint 190°F (88°C) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0620 Rev. C2 page 2 of 2 www.gamewell-fci.com .. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7270-1703:0115 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds (204) 484-6124 Fax (203) 484-7309 Email: brian.reynolds2@honeywell.com DESIGN: Models ATD-1-2, *ATD..L2F ATD-HL2 AND *ATD..HL2F (fixed temperature) and ATD-RI2, *ATDRL2F (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: ATD-1-2, *..L2F ATD-RI2, *RL2F = 135°F fixed temperature ATD-HI2, *..HL2F = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: FORMERLY: 7270-0694:256 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division 1 302 Series Rate-Anticipation Heat Detectors Description The Thermotech 302 Series rate- anticipation heat detectors operate within a conrolled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135° F or 194° F ratings. The 302 Series are normally-open devices designed especially for fire detection and alarm systems. Principles of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient temperature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature flucuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Application Information 302 Series detectors have a smooth-ceiling UL rating of 50 x 50 (15.24 x 15.24 meters) and are the only type of heat detectors having such a rating on both fixed temperature and rate anticipation. Features Immediate response. The 302 Series activates whenever ambient air temperature reaches a detectors setting,eliminating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed, shock resistant, corrosion resistant, and tamper.proff. Listings Listings and approvals below apply to the 302 Series M Rate-Anticipation Heat Detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: file S539 & E35018A. CSFM approved: file 7270-0021:001. FM approved: file Gamewell"k° A 150-Year Tradition 302 Series CS-2519 09/01/06 Page 1 of 2 by Honeywell Product Line Information 302-135: 135°F Interior Vertical Mounting, FM and UL (See Note 1). 302-194: 194°F In,erior Vertical Mounting. FM and UL (See Note 1). 302AW_135:13/'F All-Weather Vertical Mounting, FM and UL (See Note 2). 302_AW_194Ø94°F All-Weather Vertical Mounting, FM and UL (See Note 2). 302-ET-135:135°F All-Weather Vertical Mounting, FM and UL (See Note 3). 302-ET-194: 194°F All-Weather Vertical Mounting, FM and UL (See Note 3). 302-EPM-135: 135°F Explosion-Proof Mounting, UL (See Note 4). 302-EPM-194: 194°F Explosion Proof Mounting, UL (See Note 4). AP-P: Decorative white plastic adaptor plate for mounting 302 and 302-AM to 4" outlet box. Specifications Dimensions Total overall length: 4118" Base diameter: 2' Electrical Ratings Voltage Current 6-125 VAC 5 amps 6.25 V13C 1 amp 125 VDC 05 amp Note 1: For interior mounting in any atmosphere that is compatible with termi- nal screw type connections. UL rating 50' x 50' (15.24 x 13.24 meters). Note 2: Humitically sealed for moisture-proof or dust-proof installations. Requires no special backhox when the all-weather leads are properly spliced to 'THW' or equivalent type wire. Note 3: Humiticallv sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any special outlet box. Note 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. Cut-Away View C FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM S GameweH° A 150-Year Tradition SM by Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 'ww . gamewell-fci. corn A Honeywell Company © 2006 Gamewell-FCI HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Page 2 of 2 302 Series CS-2519 09/01/06 n This datasheet has been downloaded from: www.EEworld.com.cn Free Download Daily Updated Database 100% Free Datasheet Search Site 100% Free IC Replacement Search Site Convenient Electronic Dictionary Fast Search System www.EEworld.com.cn All Datasheets Cannot Be Modified Without Permission Copyright © Each Manufacturing Company CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech Inc.,2900 North 1000 Wesgden, UT 84414 Contact: Sherman Barker (801) 782-33 Fax (801) 782-1746 Email: thermotechinc@hotmail.co' DESIGN: Models 302, 302H, 302AW, 302E1 and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302- ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWI1T, Deputy State Fire Marshal Fire Engineering Division S [JGameweH MLJI . FIRE CONTROL I INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti5 Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry contacts may be made addressable when connected to the AMM-2F module. The Velocitith Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-2F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI ad- dressable series fire alarm control panels. It can be iden- tified as a manual station, heat detector, plenum detec- tor, waterilow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information Model Description AMM-2F Addressable monitor module, single circuit, Style B, Class B Velociti® and E3 Series® are registered trademarks of Honeywell International Inc. Velociti® Series AMM=2F Addressable Monitor Module Features Compact size allows easy installation Class B, Style B, initiating circuit 40 Ohm line resistance for each initiating device circuit Connects to any normally open dry contact device Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm* *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current: Alarm current: Operating temperature: Relative humidity: End-of-line Resistance: Dimensions: .000375 amps. .00060 amps. 32* to 120F (0 to 49 C) 10 to 93% (non-condensing) 47K ohms 1.3" Lx2.5"Wx0.5" D (3.3 x 6.4 x 1.3 cm) An ISO 9001-2000 Company SIGNALING ®<>MEA ! LISTED APPROVED Approved S1949 3023594 227-03-E Val., 07300.0694:178 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2008 Gamewell-FCI, All rights reserved. www.gamewell-fci.com 9020-0626 Rev. Cl page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1703:0102 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FC112 Clintonville Road Northford CT4472 Contact: Brian Reynolds (204) 484-6124 Fax (20Jf/ 184-7309 Email: brian.reynolds2honeywell.com DESIGN: Models AMM-4, *AMM..4F AMM-2 and *AMM..21F monitor modules and Models AOM, AOM-2, AOM-2R, *AOM..2RF AOM-2S and *AOM..25F control modules. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules NOTE: FORMERLY: 7300-0694:178 XLF: 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to iistee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Dl 82SFP I Addressable Systems Power-Limited Unshielded Description: Bare Copper Polyolefin Insulation Cabled construction Overall .030 SunlightResisntPVCjacket RoHS Compliant Primary Color Code: 1. Black, 2. Red, 3. Brow, 4. Blue Rating: (1 —T1 Jacket: Red NECTypeFPL (ETL)us Listed Nbets Itw requirement 7-UA as specified in the NEC UL1685Vertical Tray Flame Test *LIIVK i!i Inches Inches I Inches 18 AWG Polyolefin PVC D182F 2 Solid .182 - 16pf'ft .015 .030 6385QMt 18 MG Polyolefin PVC D184F 4 Solid .230 16pf4t .015 .030 a 5 Q,Mft 16AWG Polyolefin PVC is D162F 2 Solid .015 .030 .223 1 8pf/ft 4.016 Q,Mft Plenum Addressable Systems Power-Limited Shielded Primary Color Code: 1. Black, 2. Red Description: Rating: Jacket: Red Bare Copper • NECTypeFPLP Halar Insulation • (ETL)us Listed Overall shield 1CD/ coverage of • Meets 3031 requirements ., 4 aluminum polyester Wth IC drain vire as specified in the NEC EPA• Overall 75° C lowsmoke flexible plenumjacket • NFPA-262 Smoke & Flame Test RoHS Compliant LI!WK DI62SFP 2 Solid rldldi mi. roil 203 4.O16~AV1ft .016 1 bY/a 56pfift Toll Free: 1-866-734-7082 * 724-503-4290 * Fax: 724-503-4382 www.american-datalink.com 33