Loading...
HomeMy WebLinkAbout2175 SALK AVE; 290; FA120003; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120003 Job Address: 2175 SALK AV Status: PENDING Permit Type: FALARM Applied 1/11/2012 Parcel No: 2120210800 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: ZYNGA-STE 290 T.I. Applicant: SENTINEL SECURITY SYSTEMS 1859 S. ESCONDIDO BL ESCONDIDO, CA 760-741-0890 Owner: VENTANA REAL L L C 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 279 0 279 0 Rh 1'LooO3 7-1 ZYNGA SUITE 290 2175 SALK AVENUE CARLSBAD, CA 92008 SPECIFICATION DOCUMENTATION FOR: TENANT IMPROVEMENTS TO FIRE ALARM SYSTEM • SENTINEL SECURITY SYSTEMS 1859 S. ESCONDIDO BOULEVARD ESCONDIDO, CA 92025 C-10 #541177, ACO #140, UL #S24480 • Submitted by: Dan Pescar Phone: (760) 741-0890 December 21, 2011 K S TABLE OF CONTENTS SK5496 POWER MODULE ADDRESSABLE MODULES DATA SHEET LISTNG SHEET DATA SHEET LISTING SHEET DUCT SMOKE RESET SWITCH DATA SHEET PAGE 6-7 LISTING SHEET PAGE 8 HORN/STROBE DATA SHEET PAGE 9-11 LISTING SHEET PACE 12 ZYNGA SUITE, 290 12-21-11 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-0559:0142 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models *5808 *lFploo Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5808, lFP-100 Control Units *01FP100BD Motherboard 7628 EOL Resistor 5860/5860R1RA-1 000 Annunciator *01 FF100-IA IFP-1 00 User Interface *058631 5808 User Interface 5496 Power Module I 5824 Serial/Parallel Interface RPS-1000 Power Expander/Supply 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-ANM Addressable Notification Module SD500-LIM Line Isolation Module 5D505-616 Isolation Base SD-500 SDM Smoke Detector Module RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module *122740 *122723E Enclosures RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is no t an endorsement or recommendation of the item listed. This listing should not be used to verify corre c t operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division db CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0132 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: milce.mcisaac@honeywell.com DESIGN: Model SD500-ARM Relay Module and SD500-AIM, SD500-MIM Addressable In p u t M odules*. Models SD500-ARM provides inputs for a control unit communication circ u i t a n d h a v e t w o sets of dry relay contacts. Models SD500-AIM and -MlM provide additiona l i n p u t circuits*. Refer to listees data sheet for additional detailed product description and operatio n a l considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & o r d i n a n c e s and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compa t i b l e f i r e a l a r m control units. Refer to listees Installation Instruction Manual for details. .-, *Rev O3lllOfm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listedi This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 'LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div ofHoneywelllnt'llnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models RTS 151 RTS1 51 KEY and RA1 OOZ Duct 'Smoke Detector accessories. Refer to listee's data sheet for detailed product descriptionl and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Liste&s name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details /Th 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This l i s t i n g i s n o t an 'endorsement or recommendation of the item listed This listing should not be used to verify c o r r e c t RV" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or othe r Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED - LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St, Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PO4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR ---- INSTALLATION: . In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division