Loading...
HomeMy WebLinkAbout2173 SALK AVE; ; AS090033; PermitCity of Carlsbad Sprinkler Permit Permit No: AS090033 Job Address: 2173 SALK AV Status: ISSUED Permit Type: SPRINK Applied 4/24/2009 Parcel No: 2120210200 Approved: 4/24/2009 Lot #: 0 Reference No.: Issued: 4/24/2009 PC #: Inspector: Project Title: PACIFIC BUSINESS CENTER T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: RIO SD PLAZA II MASTER LLC C/O NEWPORT NATIONAL CORPORATION 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 WEST COAST FIRE PROTECTION 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR Ventana Real 2173 Salk LARGE ORIFICE PROOF CALCULATION FILE NUMBER: DATE: APR 23, 2009 -DESIGN DATA- OCCUPANCY CLASSIFICATION: LIGHT HAZARD DENSITY: .10 gpm/sq. ft. AREA OF APPLICATION: CORRIDOR 6 SPRINKLERS sq. ft. COVERAGE PER SPRINKLER: 400 sq. ft. MAX NUMBER OF SPRINKLERS CALCULATED: 6 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 247.5 gpm TOTAL WATER REQUIRED (including hose) : 347.4 gpm FLOW AND PRESSURE (@ BOR) : 247.4 gpm @ 30.8 psi EXISTING SYSTEM FLOW DEMAND 332.6 gpm @ 44.84 psi SPRINKLER ORIFICE SIZE: LARGE ORIFICE NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN AMATO SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 110.0 100.0 1250.0 109.1 347.4 36.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 347.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 247.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 24.0 K=14.00 8.2 40.1 1A 24.0 K=14.00 8.2 40.0 2 24.0 K=14.00 8.6 41.0 3 24.0 K=14.00 8.6 41.0 4 24.0 K=14.00 8.9 41.9 5 24.0 K=14.00 9.7 43.5 6 26.0 - - - - 13.1 - - - 6A 26.0 - - - - 13.0 - - - 7 26.0 - - - - 14.5 - - - 8 26.0 - - - - 14.5 - - - 9 26.0 - - - - 14.6 - - - 10 26.0 - - - - 14.6 - - - A 26.0 - - - - 15.0 - - - Al 26.0 - - - - 15.0 - - - A2 26.0 - - - - 15.0 - - - A3 26.0 - - - - 15.0 - - - A4 26.0 - -• - - 15.0 - - - A5 26.0 - - - 15.0 - - - A6 26.0 - - - - 15.1 - - - A7 26.0 - - - - 15.1 - - - A8 26.0 - - - - 15.2 - - - A9 26.0 - - - - 15.4 - - - A10 26.0 - - - - 15.5 - - - All 26.0 - - - - 15.6 - - - Al2 26.0 - - - - 15.7 - - - A13 26.0 - - - - 15.8 - - - A14 26.0 - - - - 15.8 - - - A15 26.0 - - - - 15.9 - - - A16 26.0 - - - - 15.9 - - - A17 26.0 - - - 16.0 - - - A18 26.0 - - - - 16.0 - - - A19 26.0 - - - - 16.0 - - - A20 26.0 - - - - 16.0 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A21 26.0 - - - - 16.0 - - - A22 26.0 - - - - 16.0 - - - 31 26.0 - - - - 15.4 - - - 32 26.0 - - - - 15.4 - - - 33 26.0 - - - - 15.4 - - - B4 26.0 - - - - 15.5 - - - B5 26.0 - - - - 15.5 - - - B6 26.0 - - - - 15.5 - - - B7 26.0 - - - - 15.5 - - - B8 26.0 - - - - 15.5 - - - B9 26.0 - - - - 15.6 - - - B10 26.0 - - - - 15.6 - - - 311 26.0 - - - - 15.7 - - - B12 26.0 - - - - 15.7 - - - 813 26.0 - - - - 15.8 - - - B14 26.0 - - - - 15.9 - - - 815 26.0 - - - - 15.9 - - - 816 26.0 - - - - 16.0 - - - 317 26.0 - - - - 16.1 - - - B18 26.0 - - - - 16.2 - - - B19 26.0 - - - - 16.3 - - - 320 26.0 - - - - 16.4 - - - B21 26.0 - - - - 16.4 - - - B22 26.0 - - - - 16.4 - - - 323 26.0 - - - - 16.4 - - - C 26.0 - - - - 16.4 - - - TOR 13.0 - - - - 25.2 - - - BOR 0.5 - - - - 30.8 - - - Ui 0.0 - - - - 31.1 - - - U2 0.0 - - - - 31.3 - - - BF1 6.0 - - - - 28.8 - - - BF2 6.0 - - - - 33.8 - - - U3 0.0 - - - - 36.4 - - - SOURCE 0.0 SOURCE 36.5 247.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -9.8 1.536 PL 78.00 PF 0.5 A 26.0 0.0 15.0 0.0 1.7 120 FTG T PE 0.0 31 26.0 0.0 15.4 0.0 0.005 TL 84.36 PV Pipe: 2 -9.8 1.536 PL 78.00 PP 0.5 Al 26.0 0.0 15.0 0.0 1.7 120 FTG T PE 0.0 B2 26.0 0.0 15.4 0.0 0.005 TL 84.36 PV Pipe: 3 -9.9 1.536 PL 78.00 PP 0.5 A2 26.0 0.0 15.0 0.0 1.7 120 FTG T PE 0.0 B3 26.0 0.0 15.4 0.0 0.006 TL 84.36 PV Pipe: 4 -40.1 1.191 PL 6.00 PF 5.8 1 24.0 14.0 8.2 40.1 11.6 120 FTG 2ET PE -0.9 6 26.0 0.0 13.1 0.0 0.254 TL 22.70 PV Pipe: 5 51.5 1.536 PL 9.33 PP 1.8 A3 26.0 0.0 15.0 0.0 8.9 120 FTG T PE 0.0 6 26.0 0.0 13.1 0.0 0.117 TL 15.69 PV Pipe: 5a -40.0 1.191 PL 6.00 PF 5.7 1A 24.0 14.0 8.2 40.0 11.5 120 FTG 2ET PE -0.9 6A 26.0 0.0 13.0 0.0 0.253 TL 22.70 PV Pipe: 6 11.4 1.536 PL 14.00 PF 0.1 6 26.0 0.0 13.1 0.0 2.0 120 FTG ---- PE 0.0 6A 26.0 0.0 13.0 0.0 0.007 TL 14.00 PV Pipe: 5A -28.6 1.536 PL 55.00 PF 2.4 6A 26.0 0.0 13.0 0.0 5.0 120 FTG T PE 0.0 34 26.0 0.0 15.5 0.0 0.039 TL 61.36 PV Pipe: 6 -41.0 1.191 PL 9.00 PF 6.8 2 24.0 14.0 8.6 41.0 11.8 120 FTG 2ET PE -0.9 7 26.0 0.0 14.5 0.0 0.264 TL 25.70 PV Pipe: 7 25.3 1.536 PL 9.33 PF 0.5 A4 26.0 0.0 15.0 0.0 4.4 120 FTG T PE 0.0 7 26.0 0.0 14.5 0.0 0.031 TL 15.69 PV Pipe: 7A -15.7 1.536 PL 69.00 PF 1.0 7 26.0 0.0 14.5 0.0 2.7 120 FTG T PE 0.0 B5 26.0 0.0 15.5 0.0 0.013 TL 75.36 PV Pipe: 8 25.4 1.536 PL 9.33 PF 0.5 A5 26.0 0.0 15.0 0.0 4.4 120 FTG T PE 0.0 8 26.0 0.0 14.5 0.0 0.032 TL 15.69 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 9 -41.0 1.191 PL 9.00 PF 6.8 3 24.0 14.0 8.6 41.0 11.8 120 FTG 2ET PE -0.9 8 26.0 0.0 14.5 0.0 0.265 TL 25.70 PV Pipe: 10 -15.6 1.536 PL 69.00 PF 1.0 8 26.0 0.0 14.5 0.0 2.7 120 FTG T PE 0.0 B6 26.0 0.0 15.5 0.0 0.013 TL 75.36 PV Pipe: 11 -9.2 1.536 PL 78.00 PF 0.4 A6 26.0 0.0 15.1 0.0 1.6 120 FTG 2T PE 0.0 87 26.0 0.0 15.5 0.0 0.005 TL 90.72 PV Pipe: 12 26.4 1.536 PL 9.33 PF 0.5 A7 26.0 0.0 15.1 0.0 4.6 120 FTG T PE 0.0 9 26.0 0.0 14.6 0.0 0.034 TL 15.69 PV Pipe: 13 -41.9 1.191 PL 7.00 PF 6.5 4 24.0 14.0 8.9 41.9 12.1 120 FTG 2ET PE -0.9 9 26.0 0.0 14.6 0.0 0.275 TL 23.70 PV Pipe: 14 -15.5 1.536 PL 69.00 PF 1.0 9 26.0 0.0 14.6 0.0 2.7 120 FTG T PE 0.0 88 26.0 0.0 15.5 0.0 0.013 TL 75.36 PV Pipe: 15 28.0 1.536 PL 9.33 PF 0.6 A8 26.0 0.0 15.2 0.0 4.8 120 FTG T PE 0.0 10 26.0 0.0 14.6 0.0 0.038 TL 15.69 PV Pipe: 16 -43.5 1.191 PL 3.00 PF 5.8 5 24.0 14.0 9.7 43.5 12.5 120 FTG 2ET PE -0.9 10 26.0 0.0 14.6 0.0 0.295 TL 19.70 PV Pipe: 17 -15.5 1.536 PL 69.00 PF 1.0 10 26.0 0.0 14.6 0.0 2.7 120 FTG T PE 0.0 39 26.0 0.0 15.6 0.0 0.013 TL 75.36 PV Pipe: 18 -7.6 1.536 PL 78.00 PF 0.3 A9 26.0 0.0 15.4 0.0 1.3 120 FTG ---- PE 0.0 310 26.0 0.0 15.6 0.0 0.003 TL 78.00 PV Pipe: 19 -5.4 1.536 PL 90.00 PF 0.2 A10 26.0 0.0 15.5 0.0 0.9 120 FTG 43 PE 0.0 Bli 26.0 0.0 15.7 0.0 0.002 TL 102.72 PV Pipe: 20 -5.0 1.536 PL 78.00 PF 0.1 All 26.0 0.0 15.6 0.0 0.9 120 FTG ---- PE 0.0 B12 26.0 0.0 15.7 0.0 0.002 TL 78.00 PV Pipe: 21 -3.2 1.536 PL 90.00 PF 0.1 Al2 26.0 0.0 15.7 0.0 0.6 120 FTG 4E PE 0.0 B13 26.0 0.0 15.8 0.0 0.001 TL 102.72 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 22 -30.4 4.310 PL 78.00 PF 0.0 A13 26.0 0.0 15.8 0.0 0.7 120 FTG 2T PE 0.0 B14 26.0 0.0 15.9 0.0 0.000 TL 133.75 PV Pipe: 23 -3.2 1.536 PL 78.00 PF 0.1 A14 26.0 0.0 15.8 0.0 0.5 120 FTG ---- PE 0.0 B15 26.0 0.0 15.9 0.0 0.001 TL 78.00 PV Pipe: 24 -4.5 1.536 PL 78.00 PF 0.1 A15 26.0 0.0 15.9 0.0 0.8 120 FTG ---- PE 0.0 B16 26.0 0.0 16.0 0.0 0.001 TL 78.00 PV Pipe: 25 -5.8 1.536 PL 78.00 PF 0.2 A16 26.0 0.0 15.9 0.0 1.0 120 FTG ---- PE 0.0 B17 26.0 0.0 16.1 0.0 0.002 TL 78.00 PV Pipe: 26 -7.1 1.536 PL 78.00 PF 0.2 A17 26.0 0.0 16.0 0.0 1.2 120 FTG ---- PE 0.0 318 26.0 0.0 16.2 0.0 0.003 TL 78.00 PV Pipe: 27 -8.5 1.536 PL 78.00 PF 0.3 A18 26.0 0.0 16.0 0.0 1.5 120 FTG ---- PE 0.0 819 26.0 0.0 16.3 0.0 0.004 TL 78.00 PV Pipe: 28 -9.6 1.536 PL 78.00 PF 0.4 A19 26.0 0.0 16.0 0.0 1.7 120 FTG ---- PE 0.0 320 26.0 0.0 16.4 0.0 0.005 TL 78.00 PV Pipe: 29 -9.3 1.536 PL 78.00 PF 0.4 A20 26.0 0.0 16.0 0.0 1.6 120 FTG ---- PE 0.0 B21 26.0 0.0 16.4 0.0 0.005 TL 78.00 PV Pipe: 30 -9.2 1.536 PL 78.00 PF 0.4 A21 26.0 0.0 16.0 0.0 1.6 120 FTG ---- PE 0.0 322 26.0 0.0 16.4 0.0 0.005 TL 78.00 PV Pipe: 31 -9.1 1.536 PL 78.00 PF 0.4 A22 26.0 0.0 16.0 0.0 1.6 120 FTG ---- PE 0.0 B23 26.0 0.0 16.4 0.0 0.005 TL 78.00 PV Pipe: 32 9.8 3.314 PL 12.00 PF 0.0 A 26.0 0.0 15.0 0.0 0.4 120 FTG ---- PE 0.0 Al 26.0 0.0 15.0 0.0 0.000 TL 12.00 PV Pipe: 33 19.6 3.314 PL 12.00 PF 0.0 Al 26.0 0.0 15.0 0.0 0.7 120 FTG ---- PE 0.0 A2 26.0 0.0 15.0 0.0 0.000 TL 12.00 PV Pipe: 34 29.5 3.314 PL 12.00 PF 0.0 A2 26.0 0.0 15.0 0.0 1.1 120 FTG ---- PE 0.0 A3 26.0 0.0 15.0 0.0 0.001 TL 12.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 35 -22.1 3.314 PL 12.00 PF 0.0 A3 26.0 0.0 15.0 0.0 0.8 120 FTG ---- PE 0.0 A4 26.0 0.0 15.0 0.0 0.001 TL 12.00 PV Pipe: 36 -47.4 3.314 PL 12.00 PF 0.0 A4 26.0 0.0 15.0 0.0 1.8 120 FTG ---- PE 0.0 A5 26.0 0.0 15.0 0.0 0.002 TL 12.00 PV Pipe: 37 -72.7 3.314 PL 12.00 PF 0.1 A5 26.0 0.0 15.0 0.0 2.7 120 FTG ---- PE 0.0 A6 26.0 0.0 15.1 0.0 0.005 TL 12.00 PV Pipe: 38 -63.6 3.314 PL 12.00 PF 0.0 A6 26.0 0.0 15.1 0.0 2.4 120 FTG ---- PE 0.0 A7 26.0 0.0 15.1 0.0 0.004 TL 12.00 PV Pipe: 39 -90.0 3.314 PL 12.00 PF 0.1 A7 26.0 0.0 15.1 0.0 3.3 120 FTG ---- PE 0.0 A8 26.0 0.0 15.2 0.0 0.008 TL 12.00 PV Pipe: 40 -117.9 3.314 PL 12.00 PF 0.2 A8 26.0 0.0 15.2 0.0 4.4 120 FTG ---- PE 0.0 A9 26.0 0.0 15.4 0.0 0.013 TL 12.00 PV Pipe: 41 -110.4 3.314 PL 12.00 PF 0.1 A9 26.0 0.0 15.4 0.0 4.1 120 FTG ---- PE 0.0 A10 26.0 0.0 15.5 0.0 0.011 TL 12.00 PV Pipe: 42 -105.0 3.314 PL 12.00 PF 0.1 A10 26.0 0.0 15.5 0.0 3.9 120 FTG ---- PE 0.0 All 26.0 0.0 15.6 0.0 0.010 TL 12.00 PV Pipe: 43 -100.0 3.314 PL 12.00 PF 0.1 All 26.0 0.0 15.6 0.0 3.7 120 FTG ---- PE 0.0 Al2 26.0 0.0 15.7 0.0 0.009 TL 12.00 PV Pipe: 44 -96.8 3.314 PL 10.00 PF 0.1 Al2 26.0 0.0 15.7 0.0 3.6 120 FTG ---- PE 0.0 A13 26.0 0.0 15.8 0.0 0.009 TL 10.00 PV Pipe: 45 -66.4 3.314 PL 4.00 PF 0.0 A13 26.0 0.0 15.8 0.0 2.5 120 FTG ---- PE 0.0 A14 26.0 0.0 15.8 0.0 0.004 TL 4.00 PV Pipe: 46 -63.2 3.314 PL 12.00 PF 0.0 A14 26.0 0.0 15.8 0.0 2.4 120 FTG ---- PE 0.0 A15 26.0 0.0 15.9 0.0 0.004 TL 12.00 PV Pipe: 47 -58.6 3.314 PL 12.00 PF 0.0 A15 26.0 0.0 15.9 0.0 2.2 120 FTG ---- PE 0.0 A16 26.0 0.0 15.9 0.0 0.004 TL 12.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Calc PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 48 -52.8 3.314 PL 12.00 PF 0.0 A16 26.0 0.0 15.9 0.0 2.0 120 FTG ---- PE 0.0 A17 26.0 0.0 16.0 0.0 0.003 TL 12.00 PV Pipe: 49 -45.7 3.314 PL 12.00 PF 0.0 A17 26.0 0.0 16.0 0.0 1.7 120 FTG ---- PE 0.0 A18 26.0 0.0 16.0 0.0 0.002 TL 12.00 PV Pipe: 50 -37.2 3.314 PL 12.00 PF 0.0 A18 26.0 0.0 16.0 0.0 1.4. 120 FTG ---- PE 0.0 A19 26.0 0.0 16.0 0.0 0.002 TL 12.00 PV Pipe: 51 -27.6 3.314 PL 12.00 PF 0.0 A19 26.0 0.0 16.0 0.0 1.0 120 FTG ---- PE 0.0 A20 26.0 0.0 16.0 0.0 0.001 TL 12.00 PV Pipe: 52 -18.3 3.314 PL 12.00 PF 0.0 A20 26.0 0.0 16.0 0.0 0.7 120 FTG ---- PE 0.0 A21 26.0 0.0 16.0 0.0 0.000 TL 12.00 PV Pipe: 53 -9.1 3.314 PL 12.00 PF 0.0 A21 26.0 0.0 16.0 0.0 0.3 120 FTG ---- PE 0.0 A22 26.0 0.0 16.0 0.0 0.000 TL 12.00 PV Pipe: 54 -9.8 4.310 PL 12.00 PF 0.0 Bi 26.0 0.0 15.4 0.0 0.2 120 FTG ---- PE 0.0 B2 26.0 0.0 15.4 0.0 0.000 TL 12.00 PV Pipe: 55 -19.6 4.310 PL 12.00 PF 0.0 B2 26.0 0.0 15.4 0.0 0.4 120 FTG ---- PE 0.0 B3 26.0 0.0 15.4 0.0 0.000 TL 12.00 PV Pipe: 56 -29.5 4.310 PL 12.00 PF 0.0 B3 26.0 0.0 15.4 0.0 0.6 120 FTG ---- PE 0.0 B4 26.0 0.0 15.5 0.0 0.000 TL 12.00 PV Pipe: 57 -58.1 4.310 PL 12.00 PF 0.0 B4 26.0 0.0 15.5 0.0 1.3 120 FTG ---- PE 0.0 B5 26.0 0.0 15.5 0.0 0.001 TL 12.00 PV Pipe: 58 -73.7 4.310 PL 12.00 PF 0.0 B5 26.0 0.0 15.5 0.0 1.6 120 FTG ---- PE 0.0 B6 26.0 0.0 15.5 0.0 0.001 TL 12.00 PV Pipe: 59 -89.4 4.310 PL 12.00 PF 0.0 B6 26.0 0.0 15.5 0.0 2.0 120 FTG ---- PE 0.0 B7 26.0 0.0 15.5 0.0 0.002 TL 12.00 PV Pipe: 60 -98.6 4.310 PL 12.00 PF 0.0 B7 26.0 0.0 15.5 0.0 2.2 120 FTG ---- PE 0.0 B8 26.0 0.0 15.5 0.0 0.003 TL 12.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 4/23/2009 C:\HASS78\VENTANA..SDF JOB TITLE: Ventana Real Large Orifice Proof Calc PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 61 -114.0 4.310 PL 12.00 PF 0.0 38 26.0 0.0 15.5 0.0 2.5 120 FTG ---- PE 0.0 39 26.0 0.0 15.6 0.0 0.003 TL 12.00 PV Pipe: 62 -129.6 4.310 PL 12.00 PF 0.1 39 26.0 0.0 15.6 0.0 2.8 120 FTG ---- P3 0.0 310 26.0 0.0 15.6 0.0 0.004 TL 12.00 PV Pipe: 63 -137.1 4.310 PL 12.00 PF 0.1 310 26.0 0.0 15.6 0.0 3.0 120 FTG ---- PE 0.0 311 26.0 0.0 15.7 0.0 0.005 TL 12.00 PV Pipe: 64 -142.5 4.310 PL 12.00 PF 0.1 Bil 26.0 0.0 15.7 0.0 3.1 120 FTG ---- PE 0.0 812 26.0 0.0 15.7 0.0 0.005 TL 12.00 PV Pipe: 65 -147.5 4.310 PL 12.00 PF 0.1 B12 26.0 0.0 15.7 0.0 3.2 120 FTG ---- PE 0.0 313 26.0 0.0 15.8 0.0 0.005 TL 12.00 PV Pipe: 66 -150.7 4.310 PL 10.00 PF 0.1 B13 26.0 0.0 15.8 0.0 3.3 120 FTC ---- PE 0.0 314 26.0 0.0 15.9 0.0 0.006 TL 10.00 PV Pipe: 67 -181.1 4.310 PL 4.00 PF 0.0 314 26.0 0.0 15.9 0.0 4.0 120 FTG ---- PE 0.0 315 26.0 0.0 15.9 0.0 0.008 TL 4.00 PV Pipe: 68 -184.3 4.310 PL 12.00 PF 0.1 B15 26.0 0.0 15.9 0.0 4.1 120 FTG ---- PE 0.0 316 26.0 0.0 16.0 0.0 0.008 TL 12.00 PV Pipe: 69 -188.8 4.310 PL 12.00 PF 0.1 316 26.0 0.0 16.0 0.0 4.2 120 FTG ---- PE 0.0 317 26.0 0.0 16.1 0.0 0.008 TL 12.00 PV Pipe: 70 -194.7 4.310 PL 12.00 PF 0.1 817 26.0 0.0 16.1 0.0 4.3 120 FTG ---- PE 0.0 B18 26.0 0.0 16.2 0.0 0.009 TL 12.00 PV Pipe: 71 -201.8 4.310 PL 12.00 PF 0.1 318 26.0 0.0 16.2 0.0 4.4 120 FTG ---- PE 0.0 319 26.0 0.0 16.3 0.0 0.010 TL 12.00 PV Pipe: 72 -210.3 4.310 PL 10.00 PF 0.1 819 26.0 0.0 16.3 0.0 4.6 120 FTG ---- PE 0.0 C 26.0 0.0 16.4 0.0 0.010 TL 10.00 PV Pipe: 72A 37.2 3.314 PL 2.00 PF 0.0 C 26.0 0.0 16.4 0.0 1.4 120 FTG ---- PE 0.0 B20 26.0 0.0 16.4 0.0 0.002 TL 2.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Caic PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 73 27.6 3.314 PL 12.00 PF 0.0 B20 26.0 0.0 16.4 0.0 1.0 120 FTG ---- PE 0.0 B21 26.0 0.0 16.4 0.0 0.001 TL 12.00 PV Pipe: 74 18.3 3.314 PL 12.00 PF 0.0 B21 26.0 0.0 16.4 0.0 0.7 120 FTG ---- PE 0.0 322 26.0 0.0 16.4 0.0 0.000 TL 12.00 PV Pipe: 75 9.1 3.314 PL 12.00 PF 0.0 322 26.0 0.0 16.4 0.0 0.3 120 FTG ---- PE 0.0 B23 26.0 0.0 16.4 0.0 0.000 TL 12.00 PV Pipe: 76 -247.5 4.310 PL 98.00 PF 3.1 C 26.0 0.0 16.4 0.0 5.4 120 FTG 73T PE 5.6 TOR 13.0 0.0 25.2 0.0 0.014 TL 223.43 PV Pipe: 77 -247.5 4.310 PL 12.50 PF 0.2 TOR 13.0 0.0 25.2 0.0 5.4 120 FTG ---- PE 5.4 BOR 0.5 0.0 30.8 0.0 0.014 TL 12.50 PV Pipe: 78 -247.5 6.044 PL 10.00 PF 0.1 BOR 0.5 0.0 30.8 0.0 2.8 140 FTG BE PE 0.2 Ui 0.0 0.0 31.1 0.0 0.002 TL 41.39 PV Pipe: 79 -247.5 6.090 PL 150.00 PF 0.3 Ui 0.0 0.0 31.1 0.0 2.7 150 FTG ---- PE 0.0 U2 0.0 0.0 31.3 0.0 0.002 TL 150.00 PV Pipe: 80 -247.5 6.044 PL 6.00 PF 0.0 U2 0.0 0.0 31.3 0.0 2.8 140 FTG ---- PE -2.6 BFi 6.0 0.0 28.8 0.0 0.002 TL 6.00 PV Pipe: 81 FIXED PRESSURE LOSS DEVICE BF2 6.0 0.0 33.8 0.0 5.0 psi, 247.5 gpm BF1 6.0 0.0 28.8 0.0 Pipe: 82 -247.5 6.044 PL 6.00 PF 0.0 3F2 6.0 0.0 33.8 0.0 2.8 140 FTG ---- PE 2.6 U3 0.0 0.0 36.4 0.0 0.002 TL 6.00 PV Pipe: 83 -247.4 6.090 PL 60.00 PF 0.1 U3 0.0 0.0 36.4 0.0 2.7 150 FTG ---- PE 0.0 SOURCE 0.0 SRCE 36.5 (N/A) 0.002 TL 60.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Calc NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 27081246 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.193 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.5 ft/sec at pipe 16. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEli ChkVlv BfyVlv GatViv AimChk DPViv NPTee 1.191 3.71 9.28 3.71 9.28 11.13 1.86 18.56 18.56 9.28 1.536 3.18 6.36 1.59 7.16 4.77 0.80 7.95 7.95 6.36 3.314 10.19 21.84 7.28 23.29 14.56 1.46 18.93 18.93 21.84 4.310 13.94 27.87 8.36 30.66 16.72 2.79 27.87 27.87 27.87 6.044 13.77 29.50 8.85 31.46 9.83 2.95 27.53 27.53 29.50 6.090 14.28 30.61 9.18 32.65 10.20 3.06 28.57 28.57 30.61 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Calc 0 0 0 0 0 H 0 - 0 I:Ll 0 C (14 0 0 0 0 0 0 0 H 0 0 0 0 0 0 0 c.l 0 C'J H SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 4/23/2009 C:\HASS78\VENTANA.SDF JOB TITLE: Ventana Real Large Orifice Proof Calc WATER SUPPLY CURVE 120+ 110*\\0\\\ I \\\\\\\ I \\\\\\\ \\\\\\ 100+ * <-100.0 psi @ 1250 gpm I Flow Test Point 90+ P 80+ R E I S I S 70+ U I R E 60+ ( I P S I 50+ ) I 40+ Ix 30+ 20+ LEGEND I if I X = Required Water Supply I 36.47 psi @ 347.4 gpm 10+ if I 0 = Available Water Supply 109.06 psi @ 347.4 gpm IT +------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) tqC0 /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series EC-1 I & EC-14 - 112 and 140 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. SEPTEMBER, 2004 Model/Sprinkler Identification Number TY5137 - Upright, 11.2K 1Y5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. TV5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O OZt c0 nm Page 2 of 8 1 - Frame Button Sealing Assembly Bulb 5 - Compression Screw 6 - Deflector* * Temperature rating is indicated on deflector Pipe thread connections per ISO 7/1 can be provided on special request. TFP22O WRENCH 3/4* ** ESCUTCHEON PLATE FLAT NPT SEATING SURFACE NOMINAL MAKE-IN CROSS UPRIGHT PENDENT SECTION FIGURE 1 SERIES EC-Il AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB NATURAL I CHROME WHITES LEAD LIQUID BRASS PLATED I POLYESTER COATED 1350F/57'C Orange LIGHT UPRIGHT K=11.2 (1Y5137) PENDENT 1, 2, 3**, 4 155F/68°C Red 175°FI79C Yellow Refer to Table B for UL and C-UL K=11.2 (57) K=14.0 (TY6237) 1,2,4 1,2,4 200'F/93°C Green 286°F/141°C Blue 135°F/57°C Orange Sensitivity Rating and Refer to Table C for REC. PENOENT K=1 1.2 (TY5237) 1, 2,3,4 N/A 155FI68°C Red 175°F179°C Yellow FM K=14.0 (TY6237) Sensitivity Rating With Style 30 Escutcheon 1, 2, 4 200°F/93'C Green 286°F/141°C Blue UPRIGHT 135F/57'C Orange ORDINARY K=11.2(TY5137) K=14.0 (TY6137) and 1, 2, 3,4 1,2,3,4 155°F/68°C Red 175°F/79C Yellow Refer to Table B for UL and C-UL Sensitivity Rating PENDENT K11.2 (TY5237) K=14.0 (TY6237) 1, 2, 4 200°F/93'C Green 286'F/141 'C Blue REC. PENOENT 135°F/57°C Orange and Refer to Table C for FM Sensitivity Rating c=i 1.2 (TY5237) K=14.0 (TY6237) With Style 40 1, 2, 4 N/A 155'F168°C Red 175°F/79°C Yellow Escutcheon 200°F/93°C Green NOTES: 11isted by Underwriters Laboratories, Inc. (UL). 21isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the City of New York under MEA 177-03-E. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. *Frame and Deflector only. Listings and approvals apply to color (Special Order). ** Pendent Only. N/A: Not Available TABLE A, A, LABORATORY LISTINGS AND APPROVALS TFP220 Page 3of8 LIGHT HAZARD 135°F 155°F 175°F 200°F 286°F ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F AREA STYLE 14x14 Up. orPend. - - - - - SR SR SR SR 14 x 14 Style 30 Recessed - - - - - SR SR SR SR 14 x 14 Style 40 Recessed - - - - - SR SR SR SR 16 x 16 Up. or Pend. OR* OR* OR* OR* OR* SR SR SR SR 16 x 16 Style 30 Recessed OR* OR* OR' OR* OR* SR SR SR SR 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 18x18 Up. orPend. OR OR* OR OR* OR* SR SR SR SR 18x18 Style 30 Recessed OR* OR OR* OR* OR* SR SR SR SR 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 20 x 20 Up. or Pend. OR* QIR° OR* SR* SR* SR SR SR SR 20 x 20 Style 30 Recessed OR* SR* QR* SR* SR* SR SR SR SR 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K = 14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-1 1 OR EC-14 SPRINKLERS (SEE TABLED FOR PERMITTED K-FACTOR(AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. OR* OR* N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. OR* OR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. QR* OR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable ° Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 1 OR EC-14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS) SR N/A N/A SR N/A N/A SR N/A N/A SR N/A N/A Page 4 of 8 TFP220 Operation 3. Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A for complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/psi'/2 (161,3 LPMIbar"2) K = 14.0 GPMIpsi1'2 (201,6 LPM/bar112) Temperature Ratings 135°F/570C to 286°F/1410C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel wfreflont Bulb ........Glass (3 mm dia.) Compression Screw ......... ......Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). UL and C-UL Listing Requirements The Series EC-1 I and EC-14 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. The Series EC-il and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non-- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 t 12 inches (25 to 300 MM). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-il and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses or bar joists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". The minimum allowable spacing be- tween the Series EC-li and EC-14 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-11 and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (TV5137, TY5237, TY6137 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. 2-7/8" DIA. (73,0 mm) 3/4' (19,1 mm 2-1/4" 01k _ 1/4" (6,4 mm) (57,2 mm) 1/8" -( I (3,2 mm) MOUNTING PLATE 1-3/8" (34,9 mm) 7/8" (22,2 mm) 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE TFP22O 2-7/8' DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER -r 1/8" FITTING (3,2 mm) MOUNTING MOUNTING SURFACE PLATE CLOSURE - J 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON Page 5 of 8 "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH - RECESS - WRENCH HEX FIGURE 5 W-TYPE 22 RECESSED SPRINKLER WRENCH FIGURE 3 SERIES EC-Il AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON DESCRIPTION AREA TY5137 (K=11.2) UPRIGHT 14 x 14 16x 16 18x18 20 x 20 TY5237 (K=11.2) PENDENT 14 x 14 16x 16 18x18 20 x 20 TY6137 (K=14.0) UPRIGHT 14 x 14 16x16 18x 18 20 x 20 TY6237 (K=14.0) PENDENT 14 x 14 16x16 18x 18 ç20x 20 I ft. =0.3048m 1ft2 =0.093m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm GROUP I ORDINARY HAZARD 0.15 GPM(FT2 GPM PSI 30 7.2 39 12.1 49 19.1 60 28.7 30 7.2 39 12.1 49 19.1 60 28.7 39 7.8 49 12.3 60 18.4 39 7.8 49 12.3 60 18.4 GROUP II ORDINARY HAZARD 0.20 GPM/FT2 GPM PSI 39 12.1 51 20.7 65 33.7 80 51.0 39 12.1 51 20.7 65 33.7 80 51.0 51 13.3 65 21.6 80 32.7 51 13.3 65 21.6 80 32.7 LIGHT HAZARD 0.10 GPMIFT2 GPM PSI 30 7.2 33 8.7 40 12.8 30 7.2 33 8.7 40 12.8 N/A N/A N/A N/A N/A N/A N/A N/A 37 7.0 37 7.0 40 8.2 Page 6 of 8 TFP22O TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-1 1 AND EC-14 SPRINKLERS Step 1. The sprinkler must be installed Installation with the deflector parallel to the mount- ing surface. Pendent sprinklers must The Series EC-11 and EC-14 Sprin- be installed in the pendent position, klers must be installed in accordance and upright sprinklers must be in- with the following instructions: stalled in the upright position. NOTES Step 2. After installing the Style 30 or Do not install any bulb type sprinkler if 40 mounting plate (or other escutch- the bulb is cracked or there is a loss of eon, as applicable) over the sprinkler pipe threads and with pipe thread liquid from the bulb. With the sprinkler held horizontally, a small air bubble sealant applied to the pipe threads, should be present. The diameter of The hand tighten the sprinkler into the air bubble is approximately 1/16 inch sprinkler fitting. (1,6 mm) for the 135°F/570C to 3/32 Step 3. Wrench tighten upright or pen- inch (2,4 mm) for the 2860F/1410C dent sprinklers using only the W-Type temperature ratings. 3 (End A) Sprinkler Wrench. Wrench A leak tight 3/4 inch NPT sprinkler joint tighten the recessed pendent sprin- klers using only the W-Type 22 Sprin- should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- kler Wrench. The wrench recess of the mum of 30 ft.Ibs. (40.7 Nm) of torque applicable sprinkler wrench (Ref. Fig- is to be used to install sprinklers. ure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. TFP22O Page 7 of 8 Care and Maintenance The Series EC-11 and EC-14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. JkJf!Il YA'ItL4l Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). Recessed Escutcheon: Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 58.705.8-011 White Color Coated ........PSN 56-705-4-011 White (RAL90I0)*PSN 56-705-3-011 Brass Plated ..............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700-9-010 White Color Coated ........PSN 56-700.4-010 White (RAL9O1O)' .........PSN 56-700-3-010 Brass Plated ..............PSN 58-700-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 PIN 51- AAA -B-CCC AAA = 893 (for TY5237 K11.2 Pendent) AAA = 894 (for TY5137 K11.2 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AAA = 896 (for TY6137 K14.0 Upright) B = 1 (for Natural Brass) B = 3 (for White [RAL90I0])* B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135°F/570C) CCC = 155 (for 1550F/680C) CCC = 175 (for 175°F/790C) CCC = 200 (for 200°F/930C) *Eastern Hemisphere sales only. TABLE PART NUMBERS FOR EC-il AND EC-14 SPRINKLERS TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Page 8of8 TFP220 X/ ictauliC V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- tern for standard commer- cial applications. They are V2107 '12708 available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- <> rates state-of-the-art, heat responsive, frangible glass eautc bulb design (standard or publication 10.01 1 for details, quick response) for prompt, V2707 '12708 precise operation. ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. Pendent '12703 V2704 I Upright The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to 3/4" (l9 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- I I TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½ (13 mm) K-Factor: 5.6 Imp. (8,1 S.l.') Nominal Thread Size: ½ NFl (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 mm U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 Recessed: V38, V38-3 Socket: V27 Finishes: O Plain brass U Chrome plated U White painted** U Custom painted** Q Lead** 155, 200, 286SR Only: Wax U Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor when pressure is mea- sured in Bar, multiply Si. units by 10.0. Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations. VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-1444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fat: 65-6235-0535 e-mail:pickmc@victaulic.com e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vicalaviclaultc.com e-mail: vlcap@victaullc.com 2544 ReeD 8/03 5 Registered Trademark of Victaulic 0 Copyright 2003 VictauliC Printed in U.S.A. :Z'IX'I1 I-i I Ii ii [t Nominal Approved Temperature Ratings °FI°C Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.I. Response Type UL FM ULC NYCIMEAt CSFM § ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2703 13 8.1 Standard upright 57-182 57.182 57-182 57-182 57-182 1h 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8,1 Standard Pendent 57-182 57-182 57-182 57-182 57-182 ½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 8,1 Standard Upto 3,4' Adjustment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick upright 57-141 57-141 57 -141 57-141 57 -141 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 8,1 Quick Pendent 57-141 57-141 57-141 57-141 57-141 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8,1 Quick Up tow AdjustmcrTt 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 No 135-200 135-200 135-200 V2708 13 8,1 Quick UptoWAdjustment 5793 1 57.93 Listings and approval as of printing. 0 All are approved open, except tor areas oesignatco No. For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. MEA #52-99-E. § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-5 5°C) up to those shown in adjacent table. Temperature - °FI°C Nominal Maximum Sprinkler Victaulic Glass Temperature Pant Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 100 68 38 Red Intermediate E 175 150 65 Yellow Intermediate F 200 93 150 65 Green High - 286 141 225 - 107 Blue Extra High f K 360 300 182 149 Purple - M Open No Bulb Standard response only. All arc approved open, except for areas designated "No". 150165 if wax coated. ORDERING INFORMATION Please specify the following when ordering: 0 Sprinkler Model Number U K-Factor 0 Sprinkler Finish U Style U Thread Size U Escutcheon Finish U Temperature Rating 0 Quantity 0 Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. P Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product. contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10-2 1 ?/1 s" (37 mm) 2W (60 mm) I (41 mm) (25 mm) Standard Pendent - V2707, V2708 1W 2W (41 mm) (60 mm) Standard Upright - V2703, V2704 2% (60 rem) Max. Hole ?(51 mm) Mill. Hole I Is Typical Calling Tile AP (17 mm) (14 mm) ,27mm) f I 11¼0 Finished Surface (30 mm) (43 mm) MAXIMUM RECESS (75 mm) - MAXIMUM EXTENSION ½" Adjustment Recessed - V2707, V2708 (Drawing not to scale) 21/d'(60 mm) Max. Hole 2" (51 mm) Mm. Hole ___________ 1Ws (33 mm) _____ 'U Typical Ceiling Tile 'h's" (24 mm) - Finished Surface ________________________ MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION 1144" Adjustment Recessed - V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2707, V2708 Pendent V2707,V27O8 Recessed Pendent V2703, V2704 Upright 40.10 -3 (24 mm) Pyle (43 mm) --;- m ---— ' N M -M - \ \ m - 10' 3,0m 8 2.4 6 1,8 4 1,2 2 0.6 C 7ps1 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa V DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 10' I I I I I I I I I 3,0 m 8' 2,4 m 7psi 48 kPa 6' 1,8 m 15 psi 103 kPa 4, 1,2 m 30 psi ------- 207 kPa 2' 0,6 m 2' 4' 6' 8' 10' 12' 14 0,6m 1,2m 1,8m 2,4m 30m 3,7m 4,3m MODELS V2703, V2104 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 0,6m 1,2m 1,8m 2,4m 30m 3,7m 4,3m 49m NOTES: Data shown Is approximate and can vary due to differences In Installation. These graphs Illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as Information for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic company. PJI products to be instated in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4