HomeMy WebLinkAbout2548 CAMPBELL PL; ; FA070012; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA070012 Job Address: 2548 CAMPBELL PL Permit Type: FALARM Parcel No: 2132610700 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 1/31/2007 Approved: 1/31/2007 Issued: 1/31/2007 Inspector: Project Title: BRESSI RANCH TWO FIRE ALARM INSPECTIONS @ $62/EA Applicant: BERG ELECTRIC 650 OPPERST ESCONDIDO CA 760-746-1003 Owner: RED TEXAS REALTY L L C C/O ST. CROIX CAPITAL CORP 4350 EXECUTIVE DR #301 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 FAolocoiSm Bergelectric Corp. Contractors & Engineers . II BRESSI RANCH 2548 & 2544 CAMPBELL PLACE CARLSBAD, CA 92008 PERMIT # CB06 1083 (BLDG. A) PERMIT # CB06 1084 (BLDG. B) S APPLICANT: BERGELECTRIC CORP. 650 OPPER STREET ESCONDIDO, CA 92029 (760) 746-1003 CONTACT: GRAIG RHODES FIRE ALARM SUBMITTAL APPROVEDAJ '1f'z(or APPROVED AS NOTED 0 NOT APPROVED, RESUBMIT CHECK'4G IS ORLV FOR COFORMANt WITH THE DEYGH CO:CFS THE POJT \NI COPU1NE IJH THE FOP•U3O OVEN IN ThE CONTRACT DOuINENIS CONTRhCiOR IS RESFONSI&IE FO ;!LEONS TO BE CONFiRMED ID P11 Hi FHE JOB S1 11"'C. AND FOP COORDATION OF THE HF ADES S FOR REVIEW AND APPROVAL MARKING 650 Opper Street • Escondido, CA 92029 9 Tel (760) 746-1003 • Fax (760) 746-4619 • C1O-#85046 Bergelectric Corp. Contractors & Engineers S II TABLE OF CONTENTS FIRE ALARM SUBMITTAL ITEM TABNO FIRE ALARM CONTROL PANEL INITIATING DEVICES INPUT/OUTPUT DEVICES 3 NOTIFICATION APPLIANCES 4 BATTERIES 5 C 650 Opper Street 9 Escondido, CA 92029 9 Tel (760) 746-1003 9 Fax (760) 746-4619 • C 1048504 Bergelectric Corp. Contractors & Engineers S II FIRE ALARM CONTROL PANEL S S 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C10485046 GE EST Fire & Life Safety S Security Control Panels Overview GE Security's QS1 life safety control panel brings big-system intel- ligent control to small applications. Designed for easy setup and simple installation, QuickStart lives up to its name in every respect. QS1's exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Devices come on-line in no time as well, thanks to QS1's built-in barcode scanner port. A simple pass of the optional scanner is all it takes to store device in- formation in the QuickStart database. The scanner can also be used for quick and easy text entry when assembling custom messages. QS1's setup routine is deceptively simple, considering this sys- tem's robust features. Supporting up to 250 intelligent detectors and modules, QS1 takes full advantage of GE Security's exclusive Signature Series technology, which provides electronic addressing, automatic device mapping, environmental compensation, and true multisensor detection. QuickStart's innovative design makes it easy to add a dialer or extra auxiliary relays. Quick-Lok option cards snap onto QS1's easily- ac-cessible DIN mounting rails. QS1 also supports as many as eight remote annunciators and up to 30 programmable front panel switches with dual LEDs for system control and display. QS1 is as simple to operate as it is to set up. Its large 14-line backlit LCD display provides easy-to-understand details concerning up to 1,000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. Four password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 ac- cess without a password to management and emergency personnel. Standard Features Supports up to 250 Signature Series intelligent devices Combines the Signature intelligent releasing module with Signa- ture multisensor detectors for reliable suppression Failsafe mode ensures uncompromised reliability Class A (Style 71 or Class B (Style 4) wiring options Capacity for eight serial annunciators Four built-in system relays Optional dual line dialer supports Contact ID and 4/2 formats Three methods of programming: QuickStart "auto-learn," front panel and personal computer (PC) Supports optional barcode scanner for direct device data entry Optional bank of 30 front panel switches with dual LEDs Up to 20 adjustable pre-alarm settings for Signature smoke detectors Wallboxes available in red or gray with optional trim ring for semi-flush mounting. Large 14-line 1224 character) backlit LCD display Four password levels, plus priority access keyswitch Message routing by event type or by individual message Alarm sensitivity by time of day or manual selection 1,000 event history buffer, plus alarm history counter 6 amp Power Supply, 4.75 amps available for external use Envoy graphics compatible Compare utility identifies system changes and simplifies testing Intelligent Single Loop Life Safety ' Control Panel .!. QS1 MEA . 5 - \f Data Sheet 85005-0113 Issue 6 - Not to be used for installation purposes. Page 1 of 8 Mounting 2.2" (5.6 cm) (12.4 cm) Optional Vandal- Resistant Door 1.68" (4.27 cm) Semi-flush mount- ing requires an optional trim ring, which odds 3/4" to all sides of the panel. S Semi-flush Mounting Surface Mounting Application Dimensions Thanks to its flexibility and simple setup and operation, QS1 is ideal for new installations in schools, apartment buildings, hospitals, of- fice buildings, and retail facilities. 7--ft The benefits brought by QS1 to retrofit applications underscores the true potential of this powerful system. As an intelligent panel, QS1 supports Signature Series devices, which can use existing wiring in most retrofit applications. This makes upgrading from a conven- tional system to analog control a simple operation with minimal disruption to normal operations at the site. NhiQuickStart,Pane!isjightfaryou? QSC QS1 QS4 Signature Series devices supported 0 1 x 250 4 t 250 Conventional class B circuits supported 3 x 16 0 3 x 16 Conventional class A circuits supported S x 8 0 5 x 8 LCD display [lines x characters) 4 x 20 14 x 16 14 x 16 Optional Zone Switch/LEDs on front panel 2 x 30 1 x 30 200 30 Option card spaces 5 or 12 1 5 or 12 For more information, see Data Sheet ... 85005 -0112 85005 -0113 85005 -0114 0 S o 5 0 11 (45.72 cm) 0 (36.2 cm) CPU / LCD Display The QS1 front panel display provides 14 lines by 16 characters of text detailing event, device, diagnostic, and programming infor- mation. Its large backlit LCD screen is easy to read and always provides at-a-glance indication of the system's state of operation. The CPU/Display Unit houses the CPU cord and mounting space for one optional LED/Switch card. AL 13 U 401 T oisploy with two oiorms shown Specifications Standby Current: 199 mA Control Panel Alarm current: 235 mA Remote annunciator Standby Current 154 mA (Full control versions) Alarm Current: 166 mA SRA Series Standby Current: 70 mA Alarm Current: 90 mA Operating Temperature: 32-120 oF 10-49 °CI environment Humidity: 93 %RH, non-condensing Failsafe Mode If the CPU loses communication with other circuit cards, the power supply card continues to monitor the system for any alarm events. If an alarm occurs on any device or circuit during a communica- tions failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 2 of 8 Remote Annunciators QS1 supports up to eight remote annunciators, which provide mirrored or customized annunciation of front panel messages and status indicators. Two models are available: The QSA Series, and the SRA Series. S Mounting ,. Field wiring Electrical box Mounting ring Annunciator Class A Wiring Class B Wiring i Annunciator I I I Annunciator I 0 CH2—)OUT I 0 CH2(—)OUT I II I II I 0 CH2(0)OUT 0 CH21010UT I 0 CH2I—)]N t I I 0 CH21-.)IN I 0 CH2lnlIN I I I 0 I I 9 CHI(—)OUT 0 CH1(—)OUT I se I I : I CHiIOIOuT I 9 CH1I*IOUT 0 CHI(—)IN t ) ]_t,o I Ct11(—)IN I I R5485 0 t I 0 CHl(+)IN I I i I 0 CHiIOIIN I 9 *241/DC OUT 0 024VDC OUT I LISTED 24 1/DC I I SUPPLY I 0 COMMON OUT I q) COMMON OUT 0 0241/DC IN I ) 24 VDC 0 0 —0 -24VDC IN I 241/DC - COMMON IN I 0 COMMON IN EARTH GND GND Class A Wiring Annunciator i I Annunciator CH2(—)OUT ØCH2(OUT 0 CH2(+)ouT —IN I CH2II C142( +)IN I CHI (—)OUT I CH1(+)OUT I CHI (—)IN I CHI(+)IN NT-A CH2lulOUT RS-485 CD CH2(—)IN CH2(+)IN CH1(—)OUT I I CHI(+)OLIT CHiI—IIN CHI(+)tN I LISTED 24 VDC O241/DC SUPPLY 24 VOC 241/DC— OUT 0241/DC OUT COMMON OUT +241/DC IN COMMON IN EAIITG COMMON OUT +241/DC IN COMMON IN Tj - QS1 Annunciator QS1 remote annunciators connect I . directly to the PS6 Power Supply Card or an external 24 Vdc filtered supply. 'j They are available with wallboxes for flush or surface mounting. Annuncia- tors are available with one annuncia- tor option space for a display card with 30 dedicated switches and LEDs. See the Ordering Table for more information. Class B Wiring 24VDC PSSTB1-13 >. I PSBTB1-14 Ylk I 0 01 10 0 S +—+— CH2 CH1 Dimensions Model Hetght Width Depth QSA-1-S 7.6 (19.46 cm) 14.25'(36.20 cm) 2.9 (7.3 cm) QSA-1-F (rough in) 6.56" (16.66 cm) 13.25' (33.66 cm) 2.1" 15.33 cm) QSA-1-F (finished) 7.8'(19.81 cm) 14.42'(36.63 cm) 1.38 (3.49 cm) Rough-in dimensions reflect the size of the cabinet where it enters the wall. Finished dimensions reflect the size of the cabinet that protrudes from the wall. XGD Graphics Driver Card The XGD Graphics Driver Card is an interface device that connects a QuickStart annunciator to on Envoy Graphic Annunciator. The XGD provides the electronics required to support 24 LEDs and 12 switches on the Envoy display panel. Multiple XGD cards can be chained together in one graphic annunciator cabinet to control larger displays. The QuickStart SRA Series annunciators can support a maximum of six XGD cards. SRA Annunci tor The QuickStart SRA Remote Annunciator is a single-loop standalone unit that can be powered by the control panel or by an approved power supply. Annunciators support Class A or Class B connection to the sys- tem RS-485 data line, but do not provide ground fault isolation. The SRA annunciator includes an RJ-12 modular jack to allow sys- tem database downloads from a laptop computer. Connection requires a programming cable (model number PROGCABLE-1, ordered separately). Annun- ciators are mounted to North American 2-gang or 4-inch square electrical boxes. Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 3 of 8 Operation Indicators Text display and controls: Displays system messages, status information, and programming menus. Arrow buttons move the display cursor. Alarm LED: Indicates a fire or life threatening emergency. Supervisory LED: Indicates an off-normal condition with the fire suppression system or related equipment. Disable/Test LED: Indicates part of the system is disabled or be- ing tested. Disabled components also signal a system trouble. Monitor LED: Indicates the operation of an ancillary system function (door closures, fan pressure switches). Trouble LED: Indicates an off-normal condition or wiring fault that compromises the integrity of the system. Ground Fault LED: Indicates a ground fault in the system wir- ing. Ground faults also signal a system trouble. CPU Fail LED: Indicates an unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. Power LED: Indicates the panel has power. Help button: Provides additional information about the device selected on the display. Status button: Displays the Status Menu from which you can identify active or disabled points in the system. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. Controls Reset button: Allows devices or zones in alarm or trouble to restore to their standby condition. The LED - indicates that the 20 21 panel is resetting. Alarm Silence button: Turns active notification appliances off depending on panel programming. Pressing Alarm Silence a second time turns them bock on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill Mode. Menu button: Displays the operator menus. Delete button: Returns to the previous menu or backspaces the cursor. Enter button: Press the Enter button to accept information or continue to the next item. Numeric keypad: Numbered buttons for entering values and making menu selections. Barcode scanner jack: Input for optional barcode scanner. Priority Access keyswitch: Enables control functions reserved is for access level 2 and above without requiring a password. S Data Sheet 85005-0113 issue 6 Not to be used for installation purposes. Page 4 of 8 1)--L[ l--( Critical Process Monitoring - with Control Waterfiow . Switch Sprinkler Supervisory Switch r[k Eleator Capture Class A Notification Appliance Circuit 051 Panel Class B Signature Data Circuit Horn Synchronization with Audible Silence Claus B Notification CR Appliance Circuit with Genesis Signals and Signal Master for Independent Horn and Strobe Control and Synchronization over two conductors. Signature F" I i Circuit (1 pr.) Damper 2nd Floor Horn and Strobe Control (2 pr) S Class A Signature Data Circuit Class A Notification Appliance Circuit with Genesis Signals and Signal Master for Independent Horn and Strobe Control and Synchronization over two conductors. 2nd Floor Class B Notification 1 Appliance Circuit Enhanced Integrity End-of-Line lJ Horn-Strobe Resistor Genesis IJJ Programmable Horn-Strobe I/O Module G Genesis Universal U Signal Master I/O Module 2 Smoke Duel Circuit Detector Input Module 2-Wire Control Relay Smoke Detector Module Smoke Detector gg Signal \ct1 with Relay Base Module '5 Smoke Detector Eg Signal Module '!ml with Isolator Base (synchronization) Manual ) Riser Monitor Pull Station Module Junction WMI Monitor Module Box More wiring suggestions can be found in the QSI Fire Alarm Control Panel Installa- tion, Operation, and Maintenance Manual, P/N 3100184. pjs.V& Critical Process . I WalertlowN. . Monitoring - Switch Supervi - F ' CT2 Sprinkler SO Switch Elevator Captufu Notification Appliance Circuit: C Hom and Strobe Synchronization with Audible Silence QS1 Panel Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 5 of 8 Standard Components and Option Cards QS1 panels come standard with a CPU/Display Unit, an SLIC Signature Loop Controller, and a PS6 Power Supply (see ordering information for details). Available QS1 option cords provide dialing capability or extra relays for anciliary control. Quick-Lok option cords snap onto DIN mounting rails for fast, no-fuss installation. One op- tion card space is available. C Cabinet with option cord and batteries installed PS6 Power Supply Card Standard Component Description The PS6 provides primary dc power to all the circuit cards installed in the cabinet. There are four 24 Vdc power output circuits - three for powering auxiliary applications, and one for powering four-wire smoke detectors - and a charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. Wiring T132 ® TBI NO C NC C SO C NO C NO NA) * - * - COON MCMI RELOVI RELACO RElAYS RELAVI SMOKE 00405 00232 * Arloc Relay 1: Form C. Contacts change position when the control panel processes on alarm signal and remain changed until all active alarm inputs restore and the control panel resets. Relay 2: Form A. Contacts change position when the panel processes a supervisory signal and remains changed until all active supervisory inputs restore. Relay 3: Form A. Contacts change position when the panel loses power or processes a trouble signal and remains changed until power returns or the trouble clears. Relay 4: Form A. Relay closes and opens according to panel programming. Smoke/Accessory Power: Jumper setting determines if the 24 Vdc inconstant or resettable. Specifications Main supply Circuit AC input: 115 or 230 Vac, 50/60 Hertz DC input: 24 Vdc batteries Charge current: 2 amps Battery charging circuit charge capacity: 40 amp hours lULl 30 amp hours (ULC( Smoke/Accessory Voltage: 24 Vdc, regulated Current 250 mA power output circuit Wire size: 12 to 18 (0.75 to 2.5 mm2) Auxiliary power output Quantity: 3 Voltage: 24 vdc full wave rectified circuits Current: 1.5 amps each Style: Form C Common alarm relay Contact rating: 1 amp Wire size: 12 to 18 AWG (0.75 to 2.5 mm') Trouble, Supervisory Style: Form A IN/Ol and programmable Contact rating: 1 amp relays Wire size: 12 to 18 AWG (0.75 to 2.5 mm') Temperature: 32 - 120° F (0-49° Cl Operating environment Humidity: 93 %RH, non-condensing Current requirements Standby current: 72mA Alarm current 96mA ii. SLIC Signature Loop Intelligent Controller 'r Standard Component Description The SLIC provides one Class A or Class B data circuit (loop) for connecting Signature Series detectors and modules. The SLIC also provides two programmable Class A or Class B notifica- tion appliance circuits (NACs) for connecting polarized 24 Vdc notification appliances such as horns and strobes. QS1 supports one SLIC. Wiring GlOSS A CiossA OUT IN LOOP + - AC A— BC B— !EOKI p ICOLI I I Ø®®000001T82 .U Ii I I I I 532 I I I I ø®®0®ø®®ITB1 i 0 BC B— AC A— BY B— A+ A— L_J NAGS NAC2 Class 31 82 Signaling Line Circuit and NACs are super- vised and power- limited. Specifications Configuration: Class B (Style 4) or Class A (Style 7) Signaling line Capacity: 125 Signature detectors circuit 125 125 Signature modules size: 18 to 12 AWG (0.75 to 2.5 mm') Circuit resistance: 65 ohms Circuit capacitance: 0.3 pf Configuration: Class B or Class A Notification Output voltage: 24 Vdc, nominal appliance Output current: 2.0 A at 24 Vdc for #1 circuits #1 and 0.8 A at 24 Vdc for #2 and #2 Wire size: 18 to 12 AWG (0.75 to 2.5 mm') End of line resistor: 10k ohms, ½ W NAC power Voltage: 24 Vdc, nominal input circuit Wire size: 18 to 12 AWG (0.75 to 2.5 mm2( Operating Temperature: 32 - 120° F (0 - 49° Cl environment Humidity: 93 %RH, non-condensing Current Standby current 33 mA requirements Alarm current: 57 mA (Both NACs on( Card spaces Requires one card space. Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 6 of 8 Specifications Style: Form A (N/O) or Form B IN/c) (jumper configurable) Output relays Contact rating: 1 amp @ 30 Vdc resistive. Wire size: 18 to 12 AWG 10.75 to 2.5 mm') Operating Temperature: 32 - 120° F 10- 490 Cl environment Humidity: 93 %RH, non-condensing Current Standby current: 11 mA requirements Alarm current: 18 ma per active relay Card spaces Requires one card space. Wiring CH2 CHI DLD Dialer Option Curd Description The DLD is a ULI/ULC listed dual line Digital Alarm Communicating Transmitter IDACT). It provides two phone line connections for send- ing system messages to a compatible Digital Alarm Communicator Receiver. The DLD supports 4/2 and Contact ID formats. It occupies one card space on the chassis rail. Wiring NJPIX SPIN MONINAR CONNECTOR FOR FIbRE USE UI RJOIX RPXI000ULAR I COTSECTONFOR POENE EPIC IC ®ØØØØT TIP RNG TIP RING TIP RNG TIP PING IN OUT IN OUT LINE I LINE Specifications Operating Temperature: 32 - 120° F 10- 49 Cl environment Humidity: 93% RH, non-condensing Current Standby: 13 mA Alarm: 20 mA requirements Dialing: 26 mA Phone Lines Two loop start lines on switched telephone network. Pulse or DTMFdkiling. Wall Connector RJ3 1X/CA31A equiv. or RJ38X/CA38A equiv. Communications Contact ID ISIA DC-05),4/2 ISlA DC-02 P31. Protocol Programming Via QuickStart, Front Panel or pc. Communications communications Canada CS-03FCC/CFR 47 Parts Compliance 15 and 68, NFPA 72, ULI 864, uLC S527-M87 Receivers Signals can be transmitted to either or both of two receivers. Telephone #s Two 24-digit numbers per receiver. Card spaces Requires one card space. ZR8 Relay Curd Option Cord Description The ZR8 provides eight dry-contact relays that TB1 can be independently configured as Form A or Form B relays. It occupies one card space on the chassis rail. Wiring oRE- +116- •RT- IbR8- I- ØØØ®®Ø®®TB Y 1 00000(bz TS,Y _ __________ -• T82 IbRi- *R2- +R3- +R4- X485 Class A RS 485 Card and QS 232 Port Option Cords Description The NT-A. which includes the X485/ RS-485 card and QS-232/UART port, provides one Class A serial remote an- nunciator bus for connecting remote annunciator panels. Control panels require the X485 card and QS-232 port, which also serves as a laptop or printer port. The X485 occupies one card space on the chassis rail. The QS- 232 port plugs into the panel CPU. Specifications Wire size 12 to 18 AWG (0.75 to 2.5 mm') twisted pair 16 twists per foot minimum) Circuit resistance 100 Ohms Circuit capacitance 0.4 pF Operating Temperature: 32 - 1200 F (0- 49° Cl environment Humidity: 93 %RH, noncondensing Current Standby: 60 mA requirements Alarm: 60 mA Card Spaces Requires one space for the NT-A SL3O SL304 SL201_5S SL3OL LED/Switch Cords'Option Cards Description The SL30 and SL30-1 provide thirty circuits for zone annunciation. Each circuit comprises two LEDs and a push button switch. The SL30 push button switches are numbered from 1 t 30 and E 13 12 43 C °°' the SL30-1 push button switches are numbered I000bOUI ir tcI from 31 to 60. The SL20L5S provides 20 cir- lL cuits for point annunciation and five circuits for custom control functions. The SL30L provides • . 30 circuits for point annunciation. SL20L5S and SL30L circuits are labeled using inserts provided with the cords. Specifications Operating environment Temperature: 32- 120° F 10-49° CI Humidity: 93% RH, non-condensing Current requirements Standby: imA Alarm: 0.75 mA per active LED Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 7 of 8 GE Ordering Information Security - Description Number hip\t. lb. (kg.) Basic Package - Enclosure, SUC, Power Supply, CPU and Display... U.S. QS1-1-G-1 Single loop system. 1 option card space. Gray enclosure, 115v transformer. 17.0 17.711 1888-378-2329 QS1-1-R-1 Single Loop System. 1 option cord space. Red enclosure, 115v transformer. 17.0 (7.71) F 866-503-3996 Note: SLIC Card includes One Signature Loop Intelligent Controller for up to 250 devices and one Class A or two Class B NACs. Canada T519 376 2430 Enc sure Accessories F 519 376 7258 QS-1-VR Vandal-resistant cabinet door, gray 3.0(1.36) Asia QS-1-VR-R Vandal-resistant cabinet door, red 3.011.361 1852 2907 8108 TRIM-1 Trim Kit - gray 5.0112.271 F 852 2142 5063 TRIM-1R Trim Kit - red 5.012.271 Australia T 613 9259 4700 - - Option Cards F 613 9259 4799 DLD Dual Line Dialer. Supports 4/2 and Contact ID formats. 1.0 (0.45) Europe ZR8 Relay Card. 8 programmable Form Acontacts. 1.0(0A5) 1322725 1120 F3227218613 - Display Options Latin America SL30 Annunciator module. Numbered 1 t 30. Two LEDs and one switch per zone. 1.010.451 1305 593 4301 Annunciator module. 20 circuits for point or. zoneannunciation, 5 SL2OLSS 1.0(0.45) F 305 593 4300 circuits for custom functions. Circuits labeled with insert card. SL30L Annunciator module. 30 circuits. Circuits labeled with insert card. 1.010.451 QS1-CPU-1 Single Loop CPU/Display, oneannunciator option space 4.0 (1.81) EST-SRA1 Intelligent/Conventional CPU/Display with integrated LCD and control 4.0 (1.81) switches. 4" square box mount. NT-A RS-485 option card. Required for Class A remote annunciation. Includes 1.0(0.45) UART card. 05-232 UART option card. Plugs into CPU. Required for PC Programming / 1.0(0.45) printer port. Included in NT-A package Remote Annunciator Cabinets (clw Interface Assembly; Require CPU/Display)... QSA-1-S Surface Remote Annunciator Cabinet. Space for one SL30 day card. 4.0(1.81) QSA-1-F Flush Remote Annunciator Cabinet. Space for one SL30 display card. 4.011.811 QSA-1-S-VR Surface Remote Annunciator Cabinet. Vandal Resistant. Space for one 4.0(1.81) SL30 display card. QSA-1-F-VR Flush Remote Annunciator Cabinet. Vandal Resistant. Space for one 4.0(1.81) SL30 display card. Programming Tools QS-CU QuickStart Panel Configuration Utility. 1.010.451 QS-Scan QuickStart scanner and programming guide. 2.0110.911 Progcable-1 Scanner port upload/download cable 1.0(0.45) 260097 Programming cable (PC to QSC, QS1, QS41 1.010.45) 'Accessories PT-1S SystemPrinter - Desktop Style 14.016.351 BC-1(R) Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 19.981 MFC-A MultiFunction Cabinet. 7.0(3.1) I0P3A RS-232 Isolator Module. 3.011.361 RPM Reverse Polarity Module. 3.0(1.36) 2-CTM City Tie Module. -- 1.0)0.45) API-8/232ME Alphanumeric Pager Interface. 11.015.0) BPS6A 6.5 Amp Booster Power Supply, 110 V 13.0(5.9) BPS10A 10 Amp Booster Power Supply, 110 V 13.0(5.9) CDR3 PSNI Coder Module 1.0(0.45) www.gesecurity.com © 2006 General Electric Company All Rights Reserved QuickStart and Signature Series are Trademarks of GE Security. Ordering options (Apply to basic packages and CPU/displays only) Languages No suffix = American English SP = Spanish 1230v or 1150 PG = Portuguese (230v only) FR = French Canadian (120v only) Power Supplies 1 = 115v transformer 2 = 230v transformer Colors G = Grey enclosure 1230v or 115vl R = Red enclosure (115v only) Examples QS1-1-G-2-SP = QS1 basic package with one option card space, grey enclosure, 230v transformer, Span- ish language. QS1-CPU-FR = QS1 CPU/display, French Canadian. S imagination at work Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 8 of 8 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-1657:207 Page 1 of I CATEGORY: Control Unit (Non High-Rise) LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models QSC, -QS1 and -QS4 fire alarm control units, followed by —1 or —2 followed by -BR, -SP, - FR, -PG or no suffix. Local, local with shunt, auxiliary, remote station, releasing service or central station. Power limited. Non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow, and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System Components: S RATING: INSTALLATION: MARKING: APPROVAL: NOTE: QSC, QSI, QS4 Control Units 7200001-01, -02; 7200004-01, -02 Enclosures 7200005-01, —02 Enclosures PS6 Power supply ZBI 6-4 Class B zone card ZA8-2 Class A zone card DLD Dialer (DACT) card ZR8 Relay card NT-A Class A, R5485 communications card QS232, 232 Port for download or printer functions SL3O LED/Switch card with switch 1-30 SL-30-1 LED/Switch card with switch 31-60 SLIC Signature expansion loop card. QS-1 -VR, -R, QS-2-VR, -R Vandal resistant doors SL3OL LED Cards 30 Zones SL2OL5S LED/Switch Cards 25 Zones 120/220 VAC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to listee's Installation Instruction Manual for details. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Formerly 7165-1591:207 and 7165-1388:237 08-1 7-05KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7120-1657:206 Page 1 of 1 CATEGORY: Annunciators LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models QSA remote annunciator cabinets, followed by —1 or —2, followed by —F or —S. Stands for 1 or 2 zone, Surface or Flush mount, which includes the RAI, remote interface subassembly. Models QSA key locked annunciator enclosures, followed by —1 or —2, followed by —F or - S, followed by —yR. Stands for I or 2 zone, Surface or Flush mount and VR stands for key locked, which includes the RAI, remote interface subassembly. Models EST-SRA1 single loop and EST-SRA4 multiple loop remote annunciators. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as annunciators for use with listee's separately listed Models QSC, -QSI and -QS4 (CSFM Listing No. 7165-1657:207) fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7120-1591:206 and 7120-1388:236 08-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. S Date Issued: JUNE 26, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 Bergelectric Corp. Contractors & Engineers S II INITIATING DEVICES 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 9 C10485046 GE EST Fire & Life Safety Security Intelligent Initiating Devices Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sensing ele- ment and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated. The microprocessor in each detector provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detec- tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communica- tions foil for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being rein- stalled (after cleaning etc.) in a different location from where it was 11101 originally. Intelligent Photoelectric Smoke Detector, SIGA-PS I - Appl.cot,on Notes Aoo,IobIe Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 1of 4 nstallation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. J 0.8 (20 mm) / 2.0' (51 mm) 4.4 (112 mm) Tamper-Resist Lever Arm - Break off to disable - (Located on Bose) '.. Access Slot for TampeR:tMethonism '- Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a 'dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity measure- ments which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detector operation should be planned to meet the requirements of the Au- thority Having Jurisdiction lAHJl. Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SlGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31h inch or 4 inch octagon boxes, 11h inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SlGA-R84, and SlGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only, t1 P ti \) \j SIGA-AB4G SIGA-SB SlGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Bose Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SlGA-RB4 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA- RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SlGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-1134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop con- troller. Remote LED SlGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gong plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 2 of 4 S S S Term Description 1 Normally Open 2 DATA IN/OUT (A 3 Common 4 DATA IN I-i 5 Not Used 6 Normally-Closed 7 DATA OUT I-I CONTACT RATING 1.0 Amp @30 VDC OUT(-) (Pilot Duty) Normally- Normally- DAT From SIgnature Controller or Previous Device OUT (+) To Next Device Audible Detector Base, SIGA-AB4G @o o© Volume selling Tone setting Default= High volume Default = Temporal pattern Cut for low volume ED (Eu Cut for steady tone To centgure Output volume or lane, cot the circuit board as shown. 24Vdc in From power Supply or 24 Vdc out previous base * To next base or EOL relay Data In From signature controller or - Data out + previous device To next Signature device Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. • -Test-Fire SIGA-IS ion SIGA-PS Photo SIGA-HRS and SIGA- HFS Rate-of-Rise/ - Fixed Temp. , - SIGA-PHS Photo Eiieàt 3D SIGA-IPHS Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly UrethaneFoam very suitable verysuitable suitable verysuitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases accept #18 AWG l0.75mm21, #16 ll.Omm°l, #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG 11.0mm21 and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. koo Standard Detector Bose, SlGA-SB, SlGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 Remote LEO (5IGA-LED) Max. Resistance per Wlre Must NOT Exceed TOO Term Description 1 Not used 2 DATA IN/OUT 1+1 3 Not Used 4 DATA lNl-1 5 Remote LED I-I 6 Remote LED 1+1 7 Not Used 8 DATA OUT DATA IN(-)I '.. La FI ." I DATA OUT (-) DATA IN (+) DATA OUT (+) From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-18, SIGA-184 Term Description 1 Not Used 2 DATA IN/OUT H 3 DATA 1N(-I 4 Not Used 5 Not Used 6 DATA OUT i-i 7 Not Used DA1 DA1,-5 From Signature Controller or Previous Device Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 3 of 4 S OUT (+) To Next Device OUT (-) Specifications T 888-378-2329 F 866-503-3996 Sensing Element Photoelectric - Light Scattering Principle Canada Storage & Operating Air Velocity Range: 0 to 5,000 ft/min 10 to 25.39 rn/sI; Humidity: 0 to 93% T 519 376 2430 Environment RH, Non-Condensing Operating Temp: 32°F to 120°F (0°C to 490C); Stor- F 519 376 7258 age Temp: -4°F to 140°F (-20°Cto 60°C) Asia Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot T 852 2907 8108 User Selected Alarm Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Less F 852 2142 5063 Sensitivity Settings Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Australia T 613 9259 4700 Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) F 613 9259 4799 Operating Current Quiescent: 45pA @ 19 V; Alarm: 45pA © 19 V Emergency Stand-alone Alarm Mode: 18mA Pulse Current: 100 pA 1100 msecl; During Communi- Europe cation: 9 mA max. T 32 2 725 1120 F 32 2 72186 13 Construction & Finish High Impact Engineering Polymer - White Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-lB Isolator Base, SIGA- Latin America Bases AB4, SlGA-AB4G Audible Bases 1305 593 4301 LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes F 305 593 4300 when in alarm Both LEDs - Glow steady when in alarm (stand-alone) wv.wgesecurity.com Compatible Remote Red LED (rnodel_SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop Controller © 2006 General Electric Company Address Requirements Uses one Device Address All Rights Reserved Agency Listings UL, ULC, MEA, CSFM UL Listed Spacing 30 ft Signature Series is a Trademark of GE Security. Ordering Information Catalog Description ipvt Number lbs (kg) SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 .23) SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2(.09) SIGA-113 Detector Mounting Base w/Fault Isolator SIGA-1134 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3)0.15) SIGA-TS4 Trim Skirt supplied with 4-inch bases) .11.041 S imagination at work Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 4 of 4 Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 1 of 6 IL I ( Application Notes Aooiloble GE EST Fire & Life Safety S Security Intelligent Initiating Devices Overview Signature Series Model SIGA-HFS and SIGA-HRS Intelligent Heat Detectors gather analog information from their fixed temperature and/or rate-of-rise heat sensing elements and converts it into dig- ital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital fil- ters remove signal patterns that are not typical of fires. Unwonted alarms are virtually eliminated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Opera- tion Guide for details. 70 foot (21.3 meter) spacing 15° F (9° Q/min rate-of-rise/135° F 157° C) ft. and 135° F 157 °C) fixed temperature type Intelligent detector c/w integral microprocessor Non-volatile memory Automatic device mapping Electronic addressing Identification of defective detectors Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards S S Intelligent Heat Detectors SIGA-HFS & SIGA-HRS Installation Spacing - The SIGA-HFS (fixed temperature) and the SIGA-HRS (fixed temperature/rate-of-rise combination) intelligent heat detectors are rated for installation at up to 70 foot (21.3 meter) Spacing. These detectors may be installed in rooms with ambient temperatures up to 100°F (380C). Status LEDs - Twin LEDs are visible from any direction. A flashing GREEN LED shows normal system polling from the loop controller. A flashing RED LED means the detector is in alarm state. Both LEDs on steady shows alarm state - stand-alone mode. Normal GREEN LED activity is not distracting to building occupants, but can be quickly spotted by a maintenance technician. Quality and Reliability - GE Security detectors are manufactured in North America to strict international ISO 9001 standards. All electronics utilize surface mount technology (SMT) for smaller size and greater immunity to RE noise. A conformal coating is used for humidity and corrosion resistance. All critical contacts are gold plated. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 1 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. J 0.8'(20 mm) 2.0'(51 mm) Ii 4.4' (112 mm) Tamper-Resist Lever Arm - Break off to disable - Access Slot for Tamper-Resist Mechanism Signature Series Overview Self-diagnostics and History Log - Each Signature Series detec- tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. This information is accessible for review any time at the control panel, PC, or by using the SIGA-PRO Signature Program/Service Tool. In the unlikely event that an unwanted alarm does take place, the control panel's history file can be called up to help isolate the prob- lem and prevent it from happening again. Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. This mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. The history log for the detector remains relevant and intact regardless of its new location. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing wire branches (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communica- tions fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Each detector on the circuit continues to collect and analyze information from its surroundings. Both the SIGA-HRS and SiGA-HFS detectors alarm if the ambient temperature increases to 1350F (57°C) or for the SIGA-HRS only, the temperature increases at a rate exceeding 15°F 190Cl/minute. If the detector is mounted to a relay base, the relay operates. Similarly, if it is mounted to an audible base, the on-board horn sounds. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the control panel when it has something new to report. This provides very fast control panel response time and allows a lower baud rate (speed) to be used for communication on the circuit. The lower baud rate offers several advantages including: - less sensitivity to circuit wire characteristics - less sensitivity to noise glitches on the cable - less emitted noise from the data wiring - twisted or shielded wiring is not required Electronic Addressing - The loop controller electronically addresses each detector, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each detector has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the circuit and assigns a "soft" address to that device's serial number. If desired, detectors can be addressed using the SIGA-PRO Signature Program/Service Tool. Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 2 of 6 S S S Remote LED (SIGA-LED) Max. Resistance per Wire *_+ Must NOT Exceed 100 S Term Description 1 Normally-Open 2 DATA IN/OUT 1+1 3 common 4 DATA INC-1 5 Not Used 6 Normally-Closed 7 DATA OUT CONTACT RATING 1.0 Amp @30 VDC (Pilot Duty) OUT C-) i Description Not Used DATA IN/OUT 1+1 DATA IN I-I Not Used Not Used DATA OUT I-I Not Used OUT (-) DATA OUT (+) To Next Device C Volume Setting Default = High volume Cut for low volume 24 Vdc in - From power supply or previous base Data In - From Signature controller or previous device * Tone setting Default = Temporal pattern Cut for steady tone To configure output volume or tone, cut the circuit board as shown. 24 Vdc out To next base or COL relay Data out To next Signature device DA1 DATA IN (+) From Signature Controller or Previous Device Application The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single S sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. - Test Fire SIGA-IS Ion - SIGA-PS Photo SIGA-HRS and SIGA HFS Rate-of-Rise! Fixed Temp. SIGA-PHS Photo Heat 3D SIGA-IPHS Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane - optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGASB, SIGA-SB4 jgkoo Relay Detector Base, SIGA-RB, SIGA-RB4 Term Description 1 Not Used 2 DATA IN/OUT 1+1 3 Not Used 4 DATA IN I-) 4 Remote LED I-I 5 Remote LED 1+1 6 Not Used 7 DATA OUT I-I DAT DATr From Signature Controller or Previous Device DATA IN (-) I '.. Qa c[j ' DATA OUT C-) DATA IN (+) DATA OUT (+) From Signature Controller To Next Device or Previous Device Normally- Normally- OUT (+) To Next Device Isolator Detector Base, SIGA-113, SIGA-184 Audible Detector Base, SIGA-AB4G Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 3 of 6 Accessories All detector mounting bases have wiring terminals that are acces- sible from the 'room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11h inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SlGA-SB4, SIGA-RB4, and SIGA-I134 mount to North American four inch square electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. SIGA-AB4G SIGA-SB SIGA-113 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SlGA-SB, SlGA-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-R84 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V. 2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the some 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SlGA-113, SIGA-184 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - if the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop control- ler. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where heat cannot reach the detector. Heat from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it The heat sensor in this device only provides a source of informa- tion to supplement the information provided by photoelectric or ionization smoke detectors which may be located nearby. The heat detector by itself does NOT provide life safety protection. Under no circumstances should heat detectors be relied on as the sole means of fire protection. Compatibility The SIGA-HFS and SIGA-HRS detectors are compatible only with GE Security's Signature Loop Controller. S Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 4 of 6 S Specifications Catalog Number SIGA-RFS SIGA-I-IRS Heat Sensing Element Fixed Temperature Fixed & Temperature! Rate-of-Rise Alarm Point Alarms at 135°F (57°C) Ambient Alarms at 135°F 157°Cl Ambient or Temp. increase above 15°F 19°Cl per mm. UL Listed Detector Spacing 70 feet 121.3 meters) center to center spacing Operating and Storage Environment Operating Temp: 32°F to 100°F (0°C to 38°C) Storage Temp: -4°F to 140°F 1-20°C to 60°Cl Humidity: 0 to 93% RH, Non-Condensing Operating Voltage 15.2 to 19.95 Vdc 119 Vdc nominal) Operating Current Quiescent: 45pA © 19 V Alarm: 45pA © 19V Emergency Stand-alone Alarm Mode: 18mA Pulse Current: 100 pA 1100 msecl Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases LED Operation SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-113 Isolator Base, SIGA-AB4, SIGA-AB4G Audible Bases On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm: Both LEDs - Glow steady when in alarm (stand-alone) Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one device address Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog, Number Description Ship Wt. lbs 1kg) SIGA-HFS Intelligent Fixed Temperature Heat Detector - UL/ULC Listed 0.5 10.231 SIGA-HRS - Intelligent Fixed Temperature/Rate-of-Rise Heat Detector - UL/ULC Listed :Atcessories SlGA-SB Detector Mounting Base SIGA-SB4 4-inch Detector Mounting Base c!w SIGA-TS Trim Skirt SIGA-RB . Detector Mounting Base w!Reloy 0.2 1.091 SIGA-RB4 4-inch Detector Mounting Base /w Relay c/w SIGA-TS Trim Skirt SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator c!w SIGA-TS Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base 0.3 10.151 SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.11.041 S S Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page of 6 U.S. T 888-378-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 1 32 2 725 1120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 www.gesecurity.com © 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. S S imagination at work Nottobeused Data Sheet 85001-0243 Issue 6 for installation purposes. Page 6 of 6 M EA Patented SIGA-278 SlGA-270 SERIES Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page lot 4 EST Fire & Life Safety Security Intelligent Initiating Devices Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of GE Security's Signature Series system. The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy pow- der-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models (SIGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. GE Security's double action single stage SlGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance SIGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models SIGA-270 models are available for one or two stage alarm sys- tems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the SIGA-270 discourages tam- pering. Intelligent device c/w integral microprocessor All decisions are made at the station allowing lower communica- tion speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties: twisted or shielded wire is not required. Non-volatile memory Permanently stores serial number, type of device, and job num- ber. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and dote of last alarm. Automatic device mapping Each station transmits wiring information to the loop controller regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address: there are no switches or dials to set. Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 °F 149 °C). Manual Pull Stations SIGA-270, SIGA-270P, SIGA-278 'It\- Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or 'Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by tine factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop con- troller when the station's pull lever is operated. The alarm condition is latched at the station. Compatibility Signature Series manual stations are compatible only with GE Secu- rity's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The SlGA-270 series are opened with a tool; the SIGA-278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Au- thority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller cata- log sheet for detailed wiring requirement specifications. Wiring Notes Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW — of SIGA-278 0 152 Red LED Green - (Alarm/Active) - L.IE O :t DATA IN (v) >- DATA OUT (v) DAtAIN(-) > DATAOUT(-> From Signature Controller Y To Next Device or Previous Device Figure 4. Single Stage Systems REAR VIEW JJ Of SIGA-270P, SIGC-270PB 0 Red LED Green LED - (ann/Aioe) (Normal) CO CD DATA IN (.2> 1 DATA OUT (.2 DATA IN() > I DATA From Signature Controller Y To Next Device or Previous Device A Figure 5. Two Stage Systems Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 2 of 4 S S Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/z inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 1112 inch (38 mm) deep 4-inch square boxes with 1-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model Cl-52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. GE Security recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system commission- ing. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Cover Release 4 5 91 Back Plate 'Switch L Glass Rod OPEN ' (0 ) Figure 1. SlGA-278 installation Cover Release Compatible Electrical Box Cover 4 ReleasE Screw ' d. Back Plate Toggle Switch Glass Rod Release Lever --. , Figure 2. SIGA-270, SlGC-270F, SIGC-270B installation Glass Rod Release Lever Figure 3. SIGA-270P, SIGC-270P8 installation Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 3 of 4 Specifications SIGA-270, SIGC-270F, 'SlGA-27013, ' Catalog Number SlGC-270B SIGC-270PB SlGA-278 Description Single Action Single Action -Two Double Action - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396pA Standby = 250pA - Activated =400pA Activated =680pA Activated =400pA - Construction & Finish Diecast Zinc -Red Epoxy Lexon - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH On-board Green LED - Flashes when polled LED Operation On-board Red LED - Flashes when in alarm Both LEDs - Glow steady when in alarm (stand-alone) - Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC (note 1), MEA, CSFM Note: SIGC-270F. SIGC-270B and SIGC-270PB are ULC listed only. Suffix "F 'indicates French markings. Suffix 8 indicates English/French biting ual markings. U.S. 1888-378-2329 F 866-503-3996 Canada 1519376 2430 F 519 376 7258 Asia 18522907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 132 2725 1120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 Aw.w.gesecurity.cam © 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. Ordering Information Catalog Ship Wt. Number, Description . . . , . lbs (kg) SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SlGA-270P Two Stage )Presignal) Fire Alarm Station, English Markings - UL/ULC Listed 1)05) SIGC-270PB Two Stage (Presignal) Fire Alarm Station, French/English Markings - ULC Listed SlGA-278 Double Action (One Stage) Fire Alarm Station, English Markings - UL/ULC Listed Accessories 32997 GA Key w/Tag - for pre-signal station (CANADA ONLY) 276-K2 GA Key - for pre-signal station (USA ONLY) 27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY) 0.1 (.05) 270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1(0.6) imagination at work Nottobeused Data Sheet 85001-0279 Issue 7 for installation purposes. Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:126 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security, Inc., 6985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SlGA-PS and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/min. NOTE: 1. Model SIGA-PHS is jnot intended for use in lieu of a required heat detector. 2. Formerly 7272-1591:126 and 7272-1388:186 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7270-1657:125 Page 1 of 1 CATEGORY: Heat Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Model SIGA-HFS and SIGA-HRS heat detectors. Model SIGA-HFS is a 135°F fixed temperature detector and Model SIGA-HRS is a 135°F fixed temperature and a 150F/mm rate of rise detector. Refer to listee's data sheet for detailed model descriptions and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible bases (CSFM S Listing No. 7300-1657:120) and fire alarm control units. NOTE: Formerly 7270-1591:125 and 7270-1388:185 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:120 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Detector Bases. Refer to listee's data sheet for detailed product description and operational considerations. Base models are as follow: BASES 5963B, 5964 B/BR 624113-002,624913-001 6251, 625113-001A, -001, -002,-003,-004, 625113-100, -200, -R100, -R200 and 6251-2 Models 6251B-001, -002, -003 and -004 suitable for releasing device service. P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047 SIGA-SB, -SB4, -RB, -RB4, -IB, -1134 and —AB4 The —RB series are suitable for releasing device service. Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 08-15--05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1657:129 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SlGA-270, SlGA-270P, and SIGA-278 noncoded, intelligent manual pull stations. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. 0 NOTE: Formerly 7150-1591:129 and 7150-1388:194 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers S II INPUT/OUTPUT DEVICES S S 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 • C10485046 SIGA-MCT2 GE EST Fire & Life Safety S Security Intelligent In put/Output Overview The SIGA-CT1 Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDCl. The actual function of these modules is determined by the "personality code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configuration. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1 and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advan- tage of the modular flexibility and easy installation that character- izes all UlO modules. Two- and six-module UlO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in GE Security enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the module through the loop controller. Plug-in (LJIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop control- ler, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Non-volatile memory Permanently stores serial number, type of device, and job number. Stand-alone operation The module makes decisions and inputs an alarm from initiating devices connected to it even if the loop controller's polling interro- gation stops. (Function availability dependent upon control panel.) Ground fault detection by address Detects ground faults right down to the device level. Input Modules SIGA-CT1, SIGA-CT2 & SIGA-MCT2 ka Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 1 of 4 S Signature Series Overview The Signature Series intelligent analog-addressable system from GE Security is an entire family of multi-sensor detectors and mount- ing bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four addi- tional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This informa- tion is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping -The Signature Data Controller (SDCl learns where each device's serial number address is installed rela- tive to other devices on the circuit. The SDC keeps a map of all Sig- nature Series devices connected to it The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SlGA-CT1 and SIGA-CT2: modules mount to North American 2112 inch164 mm) deep 1-gang boxes and 11h inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. SIGA-MCT2: mount the UIO motherboard inside a suitable GE Secu- rity enclosure with screws and washers provided. Plug the SlGA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm') wire size. UIO Motherboard 6-32 Self-tapping screws 1 n (U Plug-iIO) Caphve Module d J 5crews #6 Rat washers -Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SlGA-CT1. Two person- ality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit Al and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1)- As- sign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Personality Code 2)- Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3)- Assign to one or both circuits. Configures either circuit A or Bar both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4)- Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condi- tion is latched at the module. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 2 of 4 S S S S I DATA lN+> 1 DATA IN(-) > From Signature Controller or Previous Device A SlGA-CT1 k I I Typbool NO Initiating DOoboo UL/ULC Liolod 47011 SQL Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. S Note: Sizes #16 AWG 11.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit WireSpedfiations Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1iF per Circuit For Design Reference: Wire Size Maximum Distance toE0LR #18 AWG (0.75 mm2) #16 AWG 11.00 mm') 4,000 ft (1,219 ml #14 AWG (1.50 mm2) #12 AWG _11.50_mm21 Typical N.C. Initiating Device Typical N.C. Initiating Device INPUT 1 INPUT 2 A Style B (Class B) UL/ULC Listed ____ Style B Class B) 471(5) EOL ULIULC Us UL/ULC Listed 47KflEOL 11 Al 471(5) EOL S Red LED _______________ _______________ _______________ Green LED Red LED Q © (Normal) ______________ Green LED (Alarm/Active) 43 2 1 4 3 2 1 11 (Normal) (Alarm/ActIve) 181 TB1 DATA IN . DATA OLJT(+) (-)),— ' I I DATA OUT (+)} DATA OUF(-), DATA IN IDATAOUT(-) To Next Device From Signature Controller To Nest Device or Previous Device A SIGA-CT2 ULIULC Listed 47001 EOL SIGA.Ulolel safts moLherboard Date In I I — I A Signature T014 Qnsdt ' lNoc1Ioo,oqedfo D 0~ r de-I.—I GN.n LED Red LED Ts's No conneodons oriumper001tl005 1r040fred br S100.MCT2. S(GA-MCT2 NOTES V Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm1 (wire: Minimum #18 AWG (0.75 mm21. Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @350 pA The SlGA-lJl06R and the SIGA-UI02R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 3 of 4 GE Security Specifications Catalog Number ______________..sIG-ci J' •SIGAMCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four 49 (factory set) Four sub-types (personality sub-types (personality Codes) are available codes) are available Address Requirements Uses One Module Ad- Uses Two Module Addresses dress Operating Current Standby = 250pA; Standby = 396pA; Activated = 680pA Activated = 400pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21h inch 164 mm) deep one-gang UI0211/611/6 Mother- boxes and 11h inch (38 mm) deep 4 inch square board boxes With one-gang Covers and SIGA-MP mounting plates Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: - Environment -4°F to 140°F 1-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information - Catalog Description . Ship Wt. Number . lbs kg) SIGA-CT1 Single Input Module - UL/ULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module - UL/ULC Listed 0.4)0.15) SIGA-MCT2 Dual Input Plug-in IUIOI Module - UL. ULC Listed 0.1(0.05) Related Equipment . 27193-11 Surface Mount Box - Red, 1-gang 1.0)0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0110.61 SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0(3.1) Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 10.701 SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 10.231 SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) U.S. T 888-378-2329 F 866-503-3996 Canada 1519 376 2430 F 519 376 7258 Asia 1852 29078108 F852 2142 5063 Australia 161 392594700 F61 392594799 Europe 132 2 725 1120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 ww.gesecurity.com © 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. imagination at work S Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 4 of 4 ralm L ll Patented GE . Security EST Fire & Life Safety Intelligent In put/Output Overview The SIGA-MM1 Monitor Module and SIGA-WTM Woterfiow/Tamper Module are part of GE Security's Signature Series system. They are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The function of the SIGA-MM 1 and SIGA-WTM is determined by the factory loaded "personality code". The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The microprocessor in each module provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Standard Features Monitor and waterfiow/tamper applications Includes Alarm with delayed latching (retard) for waterfiow applications, Supervisory, and Monitor. Non-volatile memory Permanently stores serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each module transmits wiring information to the loop controller regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SlGA-PRO Signature Program/Service Tool. Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time. Less sensitive to line noise and circuit wir- ing properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (490C). Input Modules SIGA-MM1 &SIGA-WTM k et 85001-0297 Issue S Not to be used for installation purposes. Page 1 of 4 Application The duty performed by the SIGA-MMI. and SIGA-WTM is determined by their factory assigned sub-type code or "Personality Code'. SIGA-WTM NORMALLY-OPEN ALARM - DELAYED LATCHING (Fac- tory set Personality Code 2) - Assigned to one circuit. Configures circuit 1 for Class B normally-open Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. SIGA-WTM NORMALLY-OPEN ACTIVE - LATCHING (Factory set Personality Code 4)- Assigned to one circuit. Configures circuit 2 for Class B normally open dry contact Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the mod- ule. SlGA-MM1 NORMALLY-OPEN ACTIVE - NON-LATCHING (Factory set Personality Code 3) - Assigned to one circuit. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module.Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance pro- gram shows the current state of each module and other pertinent messages. Single modules may be turned off (de-activated) tempo- rarily, from the control panel. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction IAHJI. Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Availability of maintenance features is dependent on the fire alarm system used. nstallation The SIGA-MM1 and SIGA-WTM modules mount to North American 2-1/2 inch 164 mm) deep one-gang boxes and 1-1/2 inch 138 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG 12.5 mm' to 0.75 mm') wire size. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a 'soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Personality codes are assigned by the factory. No user configura- tion is required for these modules. am 01 S S Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes. Page 2 of 4 Typical Wiring The module will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2), #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG 11.0mm21 and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm') #16 AWG (1.00 mm') #14 AWG (1.50 mm') 4,000 ft 11219 ml #12 AWG (1.50 mm') Typical N.O. Waterfiow Contact Typical supervisory Contact Typical N.C. Monitor Contact A A A style B (Class B) TB2[ UL/uLcuied UL/LJLC Listed 5jleB('lass ô uvuC Listed • • • 47K0 EOL Red LE Green LEO (Aiarm/Actwe) 32 1 (Alarm/Ac (Normal) TBI DATA IN (+)DATA OUT (~)) DATA IN (+) > DATA OUT DATA IN(-)> J . DATA OUT (-) I I DATA IN(-) > . DATA OUT (.) From Signature Controller ( To Next Device From signature Controller I To Next Device or Previous Device A or Previous Device Model SIGA-WTM Model SIGA-MM1 Notes Al Maximum 25 ohms resistance per wire. Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 10 Vdc © 350JA. All wiring power limited and supervised. This module will NOT support 2-wire smoke detectors. Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes. Page 3 of 4 Specifications Fl Catalog Number SIGA MM1 S1AWTM Description Monitor Module Waterfiow/Tamper Module Type Code 48 (factory set 49 (factory set personality code 31 personality code 24) Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Standby = 396pA; Activated = 400pA Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction & Finish High Impact Engineering Polymer one-gang front plate - White Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active LEDs - Glow steady when in alarm (stand-alone) Compatibility Agency Listings Use With Signature Loop Controller UL, ULC, CSFM, MEA Mounting North American 2-1/2 inch (64 mm) deep one-gang boxes and 1- 1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. Ordering Information Catalog . . Ship Wt Description Number lbs (kg) SlGA-MM1 Monitor Module - ULIULC Listed 0.4)15) SIGA-WTM Waterfiow/Tamper Module - UL/ULC Listed Accessories 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 10.701 SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02)0.46) GE Security U.S. 1888-376-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T852 29078108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe T322725 1120 F 32 2 72186 13 Latin America T 305 593 4301 F 305 593 4300 ww.gesecurity.com © 2006 General Electric Company All Rights Reserved Signature Series is Trademark of GE Security. S S imagination at work Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes. Page 4 of 4 SIGA.MCRx MEA jj * H 111W l I NI , SGA.Cx - Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 1016 EST Fire & Life Safety S Security Intelligent Input/Output [] Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The SIGA-CR/MCR Control Relay Module provides a Form "C" dry relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in the proper ON/OFF state. Upon com- mand from the loop controller, the SIGA-CR/MCR relay activates the normally open or normally-closed contact. The SlGA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of SIGA- A134G Audible Sounder Bases. Upon command from the Signature loop controller, the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (SlGA-CR and SlGA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (SlGA-MCR and SlGA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the mother- board. UIO assemblies may be mounted in GE Security enclosures. Standard Features Provides one no/nc contact (SIGA-CR/MCR) Form "C" dry relay contact can be used to control external appli- ances such as door closers, fans, dampers etc. Allows group operation of sounder bases The SlGA-CRR/MCRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool: there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower communica- tion speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties: twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Control Relay ModuIes SIGA-CR, SIGA-MCR, SGA-CRR, SIGA-MCRR Installation SlGA-CR and SIGA-CRR: modules mount to North American 21h inch (64 mm) deep 1-gang boxes and 1112 inch (38 mm) deep 4 inch square boxes with 1-gong covers and SlGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. SlGA-MCR and SIGA-MCRR: mount the UIO motherboard inside a suitable GE Security enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG 12.5 mm' to 0.75 mm') wire size. UIO Motherboard 6-32 /- Self-tapping / screws I Module screws #6 Flat washers Cabinet or electrical enclosure Application The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (SlGA-CR/MCR) - Dry Contact Output This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Voc (or 220 Vac for non-UL applications). Personality Code 8 is assigned at the fac- tory. No user configuration is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (SIGA- CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp © 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance pro- gram shows the current state of each module and other pertinent messages. Single modules may be turned off (deactivated) tempo- rarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SlGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 2 of 6 Green LED (Normal) Notes Red LED (Alarm/Active) TB 1WWiXI1 Data ln + Zj + Data Out Green LED (Normal) Red LED (Active) Typical Wiring Modules will accept #18 AWG l0.75mm21, #16 (1.0mm21, #14 AWG 11.50mm21 and #12 AWG 12.5mm21 wire sizes. S Note: Sizes #16 AWG 11.0mm21 and #18 AWG l0.75mm21 are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed f DATA IN (+) >- DATA IN(-) ) From Signature Controller or Previous Device DATA OUT (+) DATA OUT (-) To Next Device \ Refer to Signature Loop Controller Installation Sheet for wiring specifications. NFPA 72 requires that the SlGA-CR/SlGA-MCR be installed in the same room as the device it is control- ling. This requirement may not apply in all markets. Check with your local AHJ for details. The SIGA-U106R and the SIGA-U102R do not come with TB1 4. J The SIGA-Ul06 does not come with TBB through TB 13. L Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). S SIGA-CR Control Relay Normally Open Common Normally Closed A 1234 No connections required for SIGA-MCR. Other modules may require connections. No connections required for SIGA-MCR. Other modules may require connections. SIGA-MCR Control Relay Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 3 of 6 S Typical Wiring Modules will accept #18 AWG l0.75mm21, #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. S SIGA-AB4G SIGA-AB4G SIGA-AB4G Audible Base Audible Base Audible Base EOL Relay Listed 24 VDC FNominal Powerl— Ai ______ 625 Supply LF- 1 I IIHI"l I ..JL. r I I I LI _u '-'i rH SKACR SIGA-CRR SK3ACT1 Signature i-I Controller L:J A \..... Optional SlGA-CR for disabling/disconnecting sounder base SIGA-MCRR SIGA-CRR Schematic Powet, PbsoeTOtJt PdarityRaveises When Activated SIGA-MCRR Schematic Power In Power Out Polarity reverses - + wires activated. I t— / I— 2 Audible Bases + (DO < va 0 '6254A.003 I EOL Relay required for StApeVisias S Notes Al Refer to the Signature controller installation sheet for wiring. One Pair of Wires 124 Vdc power). One Pair of Wires (Signature Data). Single Wire 124 Vdc power). The SIGA-UIOBR and the 5lGA-Ul02R do not come with TB14. The SIGA-U106 does not come with T138 through TB13. Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL. FPLP, FPLR, or an equivalent in accordance with the Notional Electrical code. 9 Maximum #12 AWG 12.5 mm') wire: Minimum #18 AWG 10.75 mm'). 10 End-of-Line Relay must monitor and report power sup- ply trouble to control panel. 11 Class B Data wiring may be "T-topped.' Signature - Data Data Out Circuit + UL/ULO Listed + 24 Vdc power - supply or 1234 123 Data Out Dii 2. circuit 1.9 X Data In Green LED (Normal) - Red LED (Active) - For ncrmal operation For General Fire Alarm Operation 87 S S S SIGA-CTI 0+ SIGA.MCRR -..1- SIGA.tJJO(R) series motherboard No connections required for 1 14 SIGA-MCRR. Other modules may require connections. Green LED (Normal) Red LED (Active) No connections required for TB15 SIGA-MCRR. Other modules may require connect ions. Optional SIGA-MCRR or SlGA-MCR for disabling/disconnecting an audible base. No connections required for SIGA-MCRR. Other modules may require connections. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 4 of 6 Specifications Catalog Number SIGA CR SIGA MCR SIGA CRR SIGA MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) Personality Code 8 IFactory Set) Address Requirements Uses 1 Module Address Operating Current Standby = lOOpA Activated = lOOpA Operating Voltage 15.2 to 19.95 Vdc 119 Vdc nominal) Relay Type and Rating Form °C" 24 VDC = 2 amps (pilot duty) 120 Voc = 0.5 amps 220 Vac (non-UL) = 0.5 amps Mounting North American 21h inch 164 mm) deep 1-gong boxes and 11h inch 138 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates Plugs into UI02R, UI06R or U106 Motherboards North American 21h inch 164 mm) deep 1-gang boxes and 1112 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates Plugs into UI02R, UI06R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F 1-20°C to 60°Cl Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL. ULC, CSFM, MEA Ordering Information Catalog:Number Description Ship Weight - lbs(kgl SIGA-CR SIGA-MCR Control Relay Module (Standard Mount) - UL/ULC Listed Control Relay Module (UIO Mount) - UL Listed 0.4(0.15) 0.1810.081 S SlGA-CRR Polarity Reversal Relay Module (Standard Mount) - ULJULC Listed 0.410.151 SlGA-MCRR Polarity Reversal Relay Module lUlO Mount) - UL Listed 0.1810.081 Related Equipment ' 27193-11 Surface Mount Box - Red, 1-gang 1 10.61 27193-16 Surface Mount Box - White, 1-gang 10.6) - SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 10.151 SIGA-UIO6R SIGA-U106 Universal Input-Output Module Board w/Riser Inputs - Six Module Positions Universal Input-Output Module Board - Six Module Positions 0.62 (0.28) 0.56(0.25) SIGA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) MFC-A Acçesories Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 10.701 SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 10.231 SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 10.461 fl Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 5 of 6 GE Security Signature Series Overview 1888-378-2329 F 866-503-3996 The Signature Series intelligent analog-addressable system from GE Security is on entire Canada family of multi-sensor detectors and mounting bases, multiple-function input and out- 1519 376 2430 put modules, network and non-network control panels, and user-friendly maintenance F 519 376 7258 and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature Asia 1852 2907 8108 device measures and analyzes the signal and decides whether or not to input an alarm. The F852 2142 5063 microprocessor in each Signature device provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Com- Australia T 613 9259 munication. F61 392594799 Self-diagnostics and History Log - Each Signature Series device constantly runs self- Europe checks to provide important maintenance information. The results of the self-check are 132 2 725 1120 automatically updated and permanently stored in its non-volatile memory. This information F 32 2 72186 13 is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Lan America Program/Service Tool. The information stored in device memory includes: 1305 593 4301 Device serial number, address, and type F305 5934300 Date of manufacture, hours of operation, and last maintenance date2 www.gesecurity.com Number of recorded alarms and troubles' © 2006 General Electric company Time and date of last alarm' All Rights Reserved Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Signature Series is a Trademark of GE Security. Automatic Device Mapping -The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing informa- tion showing branch wiring (T-tops), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configura- tion and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. On- board intelligence permits the device to operate in 1EST3 V.2 only. 'Retrievable with SIGA-PRO programming tool. S S imagination at work Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 6 of 6 S GE EST Fire & Life Safety S Security Accessories Overview The PAM-1 Relay is encapsulated multi-voltage device providing 10 Amp Form C contacts. The relay may be energized by one of three input voltages: 24 Vac, 24 Vdc, or 115 Vac. A red LED is provided which, when illuminated, indicates the relay coil is energized. The PAM-1 may be mounted by using the double-sided adhesive tape, the self-drilling screw, or loosely placed in a back box. The PAM-1 is ideal for applications where remote relays are re- quired for control or status feedback. They are suitable for use with HVAC, Temperature Control, Fire Alarm, Security, Energy Manage- ment, and Lighting Control Systems. Standard Features Completely encapsulated 10 Amp relay Relay may be energized by one of three input voltages Contains a red LED which illuminates when relay coil is ener- gized May be mounted by double-sided adhesive tape, self-drilling screw or placed in back box Convenient 6 in (150mm) wire leads for electrical connections Wiring (-)NIN -I YAAIIUL! 2 MEN RELAY ENERGIZED LED BLU c YEL N C 10.0 AMP CONTACTS ORG N.O. 115 VAC @l5niA —24 VAC @15 mA 24 VDC @ 15 mA S Multi-Voltage Control Relay Model PAM-1 Data Sheet 270066 Issue 1.1 Not to be used for installation purposes. Page 1 of 2 IWO Security -1 0 Specifications IP 1888-378-2329 F 866-503-3996 Power Requirments 15 mA per position © 24 Vdc, 24 Vac, 115 Voc Canada Relay UL Recognized SPDT 1519376 2430 Contact Rating 10 Amps © 115 Vac F 519 376 7258 Ambient Temperature -58°F to 185°F 1-50°C to 85°Cl Asia Approvals - UL Recognized components T 852 2907 8108 1.5 H x 1W .875 D inches 138.1 x 24.5 x. 22.2 mm) Dimensions F 852 2142 5063 with 6 inch 1150mm1 wire leads 18AWGll.00mm21 Australia T 613 9259 4700 392594799 Ordering Information Europe ' -- - ___ Model Description 132 2 725 11 20 F 32 272186 13 PAM-1 Single SPOT relay with LED double-sided adhesive tape, mounting screw and 6 in 1150 mml leads. Latin America 1305 593 4301 F 305 593 4300 www.gesecurlty.com © 2006 General Electric Company All Rights Reserved S imagination at work Data Sheet 270066 issue 1.1 Not to be used for installation purposes. Page 2 of 2 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-1657:121 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CT1, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI, SIGA-WTM, SlGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SlGA-MCC1, SIGA-MCC2, SIGA-MCR, SIGA-MCRR remote transponders. Models SIGA-AA30, SIGA-AA50 audio amplifier. Models SIGA-APS, SlGA-APS-220 power supply. Models SlGA-MB4, *slGA..Mp1 *SIGA..MP2 *SIGA..MP2L mounting plates; Models SlGA-UIO2R, SIGA-U106, SIGA-Ul06R motherboards. Model CS-SIGA-CC1P releasing module. Models SIGA-CCIS and SlGA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev. 09-07-2005 S This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:101 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: Richard Steele (248) 332-3900 FAX (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR-2011C, MR-201/CX, MR-204/C, MR-204/CX, PAM-1, PAM-2, PAM-2X, PAM-3, PAM-4, PAM-SD, RICA, RIC-2, *RlC..3 *RIc4 *MRRlc301 *MR..RIC..305 *MRRlC401 and *MR..Rlc..405 relay modules. Models MR-101/C, -201/C and -201/CX may employ suffix -R or -S. *The MR-RIC series relay modules will employ IT, /C, or /C/R suffixes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. S APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *Rev. 03-01-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 21, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers . II NOTIFICATION APPLIANCES ED 650 Upper Street • Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 • C10485046 0 EST Fire & Life Safety Security Notification Appliances S Overview The Genesis line of signals are among the smallest, most compact audible-visible emergency signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, GE Security Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts em- ploying this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces o smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "T" pattern, significantly exceeding UL-1971 and ULC-S526 light distri- bution requirements. Genesis strobes and horn-strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unau- thorized tampering. Genesis signals feature textured housings in architecturally neutral white or traditional fire red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Unique low-profile design - The most compact UL-1971/ULC-S526 listed strobe available - Ultra-slim - protrudes less than one inch from the wall - Attractive appearance - No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 cd model available Easy to install - Fits standard 1-gang electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pie-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribution - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improves wall penetration - Industry's first temporal strobe output Field Configurable Horns and Strobes Genesis Series MIA pending One or more patents pending j.-..-..---- - - V T-' Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 1 of 6 Application Genesis strobes are UL 1971-listed for use indoors as wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see applicatior, notes - USA). Combination horn-strobe signals must be installed in accorcance with guidelines established for strobe devices. Strobes Although all Genesis strobes are self-synchronizing, when installed with an optional synchronization module, strobe flashes from devices on the same circuit synchronize to within 10 milliseconds of each other indefinitely. This exceeds the two-hour minimum specified in the UL standards. Only one synchronization module is required per circuit. The following guidelines are based on ANSI/NFPA 72 National Fire Alarm Code (1999). When applied and installed in accordance with that code, GE Security strobes meet or exceed the illumination pro- duced by the ADA-specified 75 candela (cd) strobe at 50 feet.* Non-Sleeping Rooms and Corridors: GE Security strobes rated at less than 110 cd per UL 1971 are intended for use in non-sleeping areas only. Install with the bottom of the device at least 80 inches (2.0 m( and no more than 96 inches (2.4 ml above the finished floor. No point in any space (including corridors) required to have strobes should be more than 50 feet (15.2 ml from the signal (in the horizon- tal plane). Won Sleeping Rooms Use One Wall Mounted Model Up to 20'x 20'(6.1 x 6.1ml One 15 cd strobe Up to 30'x 3019.1 x 9.1ml One 30 cd or two 15 cd strobes Up to 40'x 40112.2 m 12.2 ml One 75 cd or two 30 cd strobes Up to 50'x 50115.2 x 15.2m) One 110 cd or two 75 cd strobes c&rid WaU Mounted Model Any Length x Max. 20 15 cd strobes spaced at 100' 130.5 ml 16.1ml Wide max. Strobes must be placed within 15'14.5m) of each end of the corridor. *ADA suggests using 75 cd strobes throughout an area, with spacing that never exceeds 50 ft from the strobe to any point in the protected space. Sleeping rooms: GE Security 110 cd strobes are intended for use in sleeping rooms and should be installed along with a smoke detec- tor. It must be wall mounted at least 80" (2.03 ml above floor level, but no closer than 24" (610 mm) to the ceiling. The distance from the strobe to the pillow must not exceed 1614.8 ml. Sleeping Rooms Use One Wall Mounted Model Any Size 110 cd within 16 feet of pillow For 177 cd ceiling horn-strobes, please refer to data sheet 85001-0559. Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent wall pen- etration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 d above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 ml above the floor. The overage ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual ef- fect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Application Notes - USA Audible signals in the public mode should never have a sound level less than 75 dBA at 10(3 ml per NFPA 72. Signals cannot exceed 120 dBA per ADA and NFPA 72 at the minimum hearing distance to audible appliance. Strobe and combination horn/strobe devices should be installed with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches 12.4 ml above the finished floor. Horns should be installed with their tops not less than 6 inches 1152 mm) below the ceiling and not less than 90 inches (2.3 ml above the finished floor. Strobes must be used to supplement audible signals wherever the average ambient sound level exceeds 105 dBA. Combination audible/visual signals must be installed in accordance with NFPA guidelines established for strobes. ADA requires visible signals in the following areas: rest rooms, meeting rooms, and other common use areas. sleeping rooms intended for use by persons with hearing impair- ment (in accordance with Title 1 of ADA). work areas used by a person with a hearing impairment (per Title 1 of ADA(. Application Notes - Canada (Based in part on 1995 Canada National Building Code) The fire alarm signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from an audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambi- ent levels, and never less than 65 dBA. In sleeping rooms the sound pressure level from an audible signal shall not be less than 75 dBA when any intervening doors between the device and the sleeping room are closed. Audible signal devices shall be installed not less than 1.8 m to the center of the device above the floor (per CAN/ULC 5524). The fire alarm audible signal shall be supplemented by fire alarm strobes in any floor area where the ambient noise level exceeds 87 dBA, or where the occupants of the floor area use ear protective devices, are located within an audiometric booth, or are located within sound insulating enclosures. This also applies to assembly occupancies in which music and other sounds associated with performances could exceed 100 dBA Strobes shall be installed in a building so that the flash from one de- vice is visible throughout the floor area or portion thereof in which they are installed. For maximum safety, GE Security recommends that strobes be installed as per the guidelines shown here under Strobe Spacing. Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 2 of 6 fl S Polarity alarm c next device end of line device Installation Genesis horns and strobes mount to any standard one-gang Sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. ured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal cir- cuit. A Genesis Signal Master is required when horn-strobe models are configured for coded systems. Non-temporal, horn-only models sound a steady tone. All Genesis signals come pre-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be config- Genesis strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Genesis Horn/Strobe with optional trim plate Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm' tic 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. WARNING These devices will not operate without electrical power, As fires frequently cause power interruptions we suggest you discuss further safeguards with your local fire protection specialist These visual signal appliances 'flash intensity may not be adequate to alert or waken - occupants in the protected area Research indicates thatthe intensity of strobe needed to awaken 90% of sleeping persons is approximately lOocd GE Security recommends that strobes in sleeping foams be 110 c minimum Note: Strobes must have continuous voltage. Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 3 of 6 WallTemporalHorn-strobes - High dB Setting 15 ' 30 75 110 15/75 *G1HDVM multi-cd UL cd* _cd* cdt:; _cd* cd** **61FH0V1575 fixed 15/75 cd RMS RMS RMSRating RMS RMS 16 Vdc 129 167 281 337 172 16 Vfvvr 176 230 397 443 269 Horns Wall Temooral Horns (G1-HD) Rating High dE (RMS) Low dB (RMS) 16 Vdc 26 19 24 Vdc 36 27 - 33 Vdc 4:. 33 16Vfwr 51 37 24Vfwr 69 ______ 52 33Vfwr 76 70 Typical HghdB LawdB Current RMS Mean RMS Mean 16 Vdc 22 17 17 14 20 Vdc 24 19 19 16 24 Vdc 27 21 22 18 33 Vdc 32 25 26 22 16Vfwr 34 15 30 14 20Vfwr 40 - 19 34 16 24Vfwr 45 21 38 18 33Vfwr 52 24 47 22 Wall Horns (G1-P) UL Designation Voltage Range Max. Current, RMS Regulated 24 Vdc 16-33Vdc 13 m 24fwr 16-33Vfwr 11 m Typical Current RMS Mean 24 Vdc 10 10 24 Vdc 11 11 31 Vdc 12 12 20Vfwr 9 8 24Vfwr 10 9 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods cnd instruments used. GE Security recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AN calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, Circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flawing through the device. The RMS current Inat the mean cur- rent) determines the heating affect and therefore, the trip and hold threshold for those cevices. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. I] Current Draw Strobes, Horn-Strobes Multi-cd Wall Strobes (G1-VM) UL 15 cd* r 30 cd* 15/75 cd** 75 cd-,110 cd* Rating RMS RMS RMS RMS RMS l6Vdc 103 141 106 255 311 16Vfwr 125 179 170 346 392 *G1VM multi-cd; **G iF V1575 fixed 15/75 cd TypicdI 15cd 30cd 15/75[75cd- 110 cd. Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 85 79 127 124 150 140 245 243 285 283 20 Vdc 71 66 98 96 123 114 188 186 240 238 24 Vdc 59 55 82 80 104 97 152 150 191 190 33 Vdc 46 44 64 63 84 77 112 111 137 136 16Vfwr 119 64 169 97 223 126 1 332 203 376 240 20V 103 51 143 76 189 100 253 150 331 198 24Vfwr 94 44 129 65 169 85 218 121 262 152 33Vfwr 87 37 112 52 148 1 68 179 89 205 106 Typical '15 cd- 0cd' 15/75 75 cd 110 cd Current RMS. Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 102 89 135 129 160 152 246 242 309 305 20 Vdc 88 77 109 104 137 129 193 190 248 243 24 Vdc 81 71 94 90 122 114 161 158 203 200 33 Vdc 74 64 72 74 106 98 124 121 154 151 16Vfwr 144 77 182 106 247 143 352 212 393 249 20Vfwr 141 68 162 87 220 120 274 158 362 210 24Vfwr 136 65 152 76 203 106 235 133 282 165 33Vfwr 125 54 144 65 196 94 201 101 232 123 Wall Temporal Horn-strobes - LowdB_Setting 15 30 75 110 15/75 UL C_..L__ Rating RMS ---- RMS. RF1S RMS RMS 16 Vdc 122 L60 274 330 146 *G1HDVM multi-cd 16Vfwr 162 j 216 383 429 231 **G1FHDV1575 fixed 15/75cd Typical 15d. 30 cd 15/75 75cd U0cd, Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 96 84 130 124 158 149 243 240 302 297 20Vdc 79 70 104 99 133 124 189 186 241 237 24 Vdc 68 61 88 84 119 110 156 154 197 --i- 193 33 Vdc 56 52 71 68 100 93 118 116 146 143 16Vfwr 128 69 180 104 241 139 344 204 389 244 20Vfwr 118 60 157 84 213 115 266 156 343 200 24Vfwr 113 54 144 74 195 101 230 128 279 161 33Vfwr 112 48 137 64 182 87 197 99 226 117 [1 Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 4 of 6 fl dBA output Temooral Horns. Horn-strobes (G1-HD. G1-HDVM series) U L464 ______ Average Peak High dB Setting Temporal Steady I Temporal! Steady Temporal! Steady 16 Vdc 81.4 ]85.5 91.4 94.2 24 Vdc 84.4 I 88.6 94.5 I 97.6 33 Vdc 86.3 1 90.4 96.9 j 99.5 U1464 Average Peak .Low dB Setting I Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 1 76.0 80.1 86.3 j 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 I 95.3 Steady Tone Horns (G1-P series) UL44 Ayerage Peak 16 Vdc 77 dBA, min 85 dBA 91 dBA 16 Vfwr 77 dBA, mm 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet 13.01ml. UL464 values measured in reverberation room. Average and Peak values are measured in anechoic chamber. Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at loft) Light output - (effective cd) Percent of UL rating versus angle P0,SULR.thg / /75• N / S Specifications Housing Red or white textured uv stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Mounting M Flush mount: 2½ inch (64 mm) deep one-gang box (indoor wall mount only) Surface mount: Model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG 10.75 mm' to 2.5 mm') wire size Operating environment Indoor only: 32-1207 lo-49°Cl ambient temperature. 93% relative humidity Agency listings/approvals UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CSFM, CE, FCC, IMEA, FM pending). (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions lHxWxDl Signal: 4-1/2" x 2-3/4"x 13/16"(113 mm x 68 mm x 21 mm) Trimplate: 5(127 mm); Height - 5-7/8'(149 mm); Depth - 1h"(13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G1M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16- 33 Vdc or unfiltered 16-33 Vdc FWR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638. ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe output rating DL 1971: 15 cd (fixed 15/75 cd models) UL 1638, ULCS526: 75 cd (fixed 15/75 cd models) G1-VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional G1M Strobe flash rate Genesis Signal Master indefinitely within 10 milliseconds or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G 1 Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Compatible synchronization G1M, G1M-RM, SIGA-CC1S, SlGA-MCC1S modules* G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Horn pulse rote G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) G1-P steady-tone horns: continuous, steady tone only Temporal audible pattern ½ sec ON, ½ sec OFF. ½ sec ON, ½ sec OFF, ½ sec ON, 11h sec OFF, then repeat cycle * Not compatible with G1-P Series horns Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page of 6 MountmcAccessories G1T GIRT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15)0.7) G1T-FIRE GIRT- Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) FIRE with "FIRE" markings 27193-16 27193-11 One-gang surface mount box 1(0.4) Genesis Series is a Trademark of GE Security. S GE Security S Ordering Information Catalog Number Description . Ship Wt.: lbs (kg) - White Red Finish Finish G1R- Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, G1-HDVM HDVM selectable high/low dB output) G1-VM G1R-VM Genesis Strobe (selectable 15, 30, 75, or 110 cd output) G1-HD G1R-HD Genesis Temporal Horn (selectable high/low d8 output) G1-P G1R-P Genesis Steady Horn (not compatible with Genesis Signal Master) G1F- G1RF- Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, HDVM HDVM selectable high/low dB output) - with "FIRE" marking Genesis Strobe (selectable 15, 30, 75, or 110 cd output) 0.25 G1F- VM G1RF- VM - with "FIRE" marking (0.11) Genesis Temporal Horn (selectable high/low dB output) G1F-HD G1RF-HD - with "FIRE" marking Genesis Steady Horn with "FIRE" marking GY-P G1RF-P (not compatible with Genesis Signal Master) GiF- G1RF- 15/75 cd temporal horn-strobe, hi/la dB-24V H0V1575 H0V1575 - with "FIRE" marking (see note 1) G1F- G1RF- 15/75 cd strobe - with FIRE marking (see note 1) V1575 t'1575 U.S. 1888-378-2329 F 866-503-3996 Canada 1519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Australia 1 613 9259 4700 F 613 9259 4799 Europe 1 32 2 725 1120 F 32 2 72186 13 Latin America 1305 593 4301 F 305 593 4300 ww.gesecurity.com © 2006 General Electric Company All Rights Reserved Synchronization Modules G1M Genesis Signal Master - Snap-on Mount 0.2(0.1) G1M-RM Genesis Signal Master - Remote Mount (1-gang) SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO( 0.18(0.08) Note 1: These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd out- put component complies with UL1971, while the 75 cd output component complies with UL 1638. - FIRE Genesis Horn-Strobes may be ordered in red or white, with or without 'FIRE' marking. Order matching trim plates separately. imagination at work Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 6 of 6 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:218 Page 1 o 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941)308-8123 DESIGN: Models G1-VM, G1R-VM, GIF-VM, G1RF-VM, GI41575, GIR-V1575, GIF41575, and G1RF-V1575 synchronizable type strobe lights. The suffix R refers to red rather than white housing and the suffix F refers to the word "FIRE" refers to a silk-screened word "FIRE" on the strobe housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 V dcNFWR Candela: G1-VM series 15cd, 30cd, 60cd, 75cd, 110cd Selectable GI41575 series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Units are synchronizable when used with Models Gi M or G1M-RM sync module (CSFM Listing No. 7300-1657:201) which may employ Models SIGA-CCIS or SIGA-MCCIS Auto-Sync output modules as an accessory (CSFM Listing No. 7300-1657:121). For indoor use and wall mount only. NOTE: Formerly 7125-1591:218 08-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-1657:202 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models "EST" G1-HVI5, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -H0V75, -HOVIIO, GIF-HOVI5, -HOV30, -HOV60, -H0V75, -HOV110, GlRF-HOVIS, -HOV30, -HOV60, -H0V75, -HOV1I0, G1-HDVM, G1R-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, GI- HDV1575, GIR-HDV1575, GIF-HDV1575, and G1RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 VdcNfwr - Models GI-HDVM, GIR-HDVM, GIF-HDVM, G1RF- HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, GI-HDV1575, GI R-HDV1575, GI F-HDV1575, GI RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, ll0cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models GI-HDV1575, Gi R-HDV1575, G1 F-HDV1575, S G1RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135- 1657:230). For indoor use and wall mount only. Models GC-HDVM and GCF-HDVM for ceiling mount only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Formerly 7125-1591:202 08-17-05 1! This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers S. II BATTERIES S fl 650 Opper Street • Escondido, CA 92029 9 Tel (760) 746-1003 9 Fax (760) 746-4619 • C1O-#85046 S UB12350 (12V35Ah) NOTE S Nominal Voltage 12V Nominal Capacity (20HR) 35Ah Length 197 +/-lmm(7.76 inches) Dimensions Width 130 +/-lmm(5.12 inches) Height 156 +/-lmm(6.14 inches) Total Height 180 +/-lmm(7.09 inches) Weight Approx. 11.107 kg (24.441bs) Standard Terminal BI-M5 bolt & nut Dimensions (min):+/.nim 130 [fl____ 156 180 Ii 196 Standard Terminal mm B! 16 8.75P ii 16 (M5 bolt & nut) 0 UB12350 (12V35Ah) fl Max. Discharge Current (5 sec.) 180A 20 hour rate (1.7A) 35 Ah 10 hour rate (3.0A) 30.5 Ah Capacity Cycle 14.4 to 15.OV (-30mV/°C) 5 hour rate (5.4A) 21.6 Ah Constant 1 hour (20A) 18 Ah Voltage Charge Internal Resistance Fully charged battery (20°C, Standby 13.5 to 13.8V (-20mV/°C) 68°F) 10milhiohms - I)MaNe - 13.0 I 3A : -ij--- ii 2A 62A 34A 1 2 3 5 10 20 30 60 2 3 5 10 20 30 nn DchargeThne !IU JIM,&UtEII ..iiiuiiu.ui...• INLiIiURUU 13.0 mm, 00% WIN 4141 1141 man 0-0 H MEN S 11.0 110.0 9,0 8.0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 tin Discharge Time iuIIIIIuuIIIui S