HomeMy WebLinkAbout1 LEGOLAND DR; ; FPC2020-0027; PermitCL7city of
PERMIT REPORT Carlsbad
Print Date: 12/02/2020 Permit No: FPC2020-0027
Job Address: 1 LEGOLAND DR, CARLSBAD, CA 92008-4610 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2111000900 Track #: Applied: 02/10/2020
Valuation: $89,248.88 Lot #: Issued: 02/13/2020
Occupancy Group: Project #: Finaled Close Out: 03/12/2020
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: WOK & BOWL (LEGOLAND) -SPRINKLER TI (2 HEADS)
Applicant: FPContractor:
A AND D FIRE SPRINKLERS INC A AND D FIRE SPRINKLERS INC
TREVOR TORRES 7130 CONVOY CT
7130 CONVOY CT SAN DIEGO, CA 92111-1019
SAN DIEGO, CA 92111-1019 (858) 277-3473
(858) 277-3473
FEE AMOUNT
FIRE NFPA 13 or 13R System 6 heads or less $125.00
Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
C-
tqco® Worldwide
Contacts I www.tyco-fire.com
Series TYB - 2.8,1 5.6., and 80 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
General
Description
The TYCO Series TY-B 2.8, 5.6,
and 8.0 K-factor, Upright, Pendent,
and Recessed Pendent Sprinklers
described in herein are standard
response, standard coverage, decora-
tive 5 mm glass bulb-type spray sprin-
klers. They are designed for use in light,
ordinary, or extra-hazard commercial
occupancies such as banks, hotels,
shopping malls, factories, refineries,
and chemical plants.
The TY-B Recessed Pendent Sprinkler,
where applicable, is intended for use in
areas with a finished ceiling. It uses a
two-piece Style 10(1/2 in. NPT) or Style
40 (3/4 in. NPT) Recessed Escutcheon.
The Recessed Escutcheon provides
1/2 in. (12,7 mm) of recessed adjust-
ment or up to 3/4 in. (19,1 mm) of total
adjustment from the flush pendent
position. The adjustment provided by
the Recessed Escutcheon reduces the
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
Corrosion-resistant coatings, where
applicable, are utilized to extend
the life of copper alloy sprinklers
beyond what would be obtained
when exposed to corrosive atmo-
spheres. Although corrosion-resistant
coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing
is not representative of all possible
corrosive atmospheres. Consequently,
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fall
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 8
it is recommended that the end-user be
consulted about the suitability of these
coatings for any given corrosive envi-
ronment. The effects of ambient tem-
perature, concentration of chemicals,
and gas/chemical velocity, should be
considered as a minimum, along with
the corrosive nature of the chemical to
which the sprinklers will be exposed.
An intermediate level version of the
Series TV-B Pendent Sprinkler can be
obtained by utilizing the Series TV-B
Pendent Sprinkler in combination with
the Model S2 Shield.
NOTICE,
The Series TY-B 2.8, 5.6, and 8.0 K-fac-
tor, Upright, Pendent, and Recessed
Pendent Sprinklers described herein
must be installed and maintained in
compliance with this document, as well
as with the applicable standards of the
National Fire Protection Association
(NFPA), in addition to the standards of
any other authorities having jurisdiction.
Failure to do so may impair the perfor-
mance of these devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condi-
tion. Contract the installing contrac-
tor or product manufacturer with any
questions.
NFPA 13 prohibits installation of 1/2 in.
NPT sprinklers with K-factors greater
than 5.6 in new construction. They are
intended for retrofit in existing sprinkler
systems only.
Sprinkler
Identification
Numbers (SIN)
TY1151 ... Upright 2.8K, 1/2 in. NPT
TY1251 . . .Pendent 2.8K, 1/2 in. NPT
TY3151 ... Upright 5.6K, 1/2 in. NPT
fTY3251 . . .Pendent 5.6K, 1/2 in. NPT
TY4151 ... Upright 8.OK, 3/4 in.-NPT---'
TY4251 . . .Pendent 8.0K, 3/4 in. NPT
TY4851 ... Upright 8.01K, 1/2 in. NPT
TY4951 . . .Pendent 8.01K, 1/2 in. NPT
JULY 2018
Technical
Data
Approvals
UL and C-UL Listed
FM, LPCB, VdS, and NYC Approved
Refer to Table A for complete approval infor-mation, including corrosion-resistant status.
Maximum Working Pressure
Refer to Table B
Discharge Coefficient
K=2.8 GPM/psi½ (40,3 LPM/bar)
K=5.6 GPM/psi" (80,6 LPM/bar½)
K=8.0 GPM/psi/2 (115,2 LPM/bar")
Temperature Ratings
Refer to Table A
Finishes
Sprinkler: Refer to Table C
Recessed Escutcheon: Signal or Pure White,
Grey Aluminum, Jet Black, Chrome Plated,
or Natural Brass
Physical Characteristics Frame ............................Bronze
Button ......................Brass/Copper
Sealing Assembly. . Beryllium Nickel w/TEFLON
Bulb...............................Glass
Compression Screw .................Bronze
Deflector .........................Copper
Bushing (K=2.8) ....................Bronze
TFPISI
1/2 NPT*
UPRIGHT
CROSS SECTION RECESSED PENDENT PENDENT UPRIGHT
7/16
1,1 mm)
OMINAL
lAKE-IN
2-3/16
(55,6 mm)
2-3/16
(55,6 mm)
1-1/2
(38,1 mm)
STYLE 1(
RECESSEL.J
ESCUTCHEON
TFPI5I
Page 2 of 8
CEILING PLATE
SEATING SURFACE
-/7
nm)
1 - Frame 5 - Compression
2 - Button Screw
7 3 - Sealing 6 - Deflector*
Assembly 7 - Bushing
1 4 - Bulb
2 * Temperature rating is
I I indicated on Deflector.
II
5 ** Pipe thread connections
per ISO 7-1 can be
6* provided on special
request. I
i
7/16'
(11,1 mm)
NOMINAL
MAKE-IN
I 2-3/16
_____ (55,6 mm)
1/2" NPT**
/
WRENCH
FLATS UPRIGHT PENDENT CROSS SECTION
FIGURE 1
SERIES TY-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS
2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE
* Temperature rating
is indicated on
Deflector.
** Pipe thread connections per
ISO 7-1 can be provided on ESCUTCHEON
special request. PLATE SEATING
SURFACE
______________________ _____________________________________
_
L1/2
H
7/16"
______
mm)
11,1 mm)
OMINAL 6 MAKE-IN
_j
I 23/16U,/,,/
(55,6 mm)
_______
t WRENCH
FLATS
PENDENT
1 - Frame 3 - Sealing 5 - Compression
2 - Button Assembly Screw
4 - Bulb 6 - Deflector*
/ I\
fl 2
4
-5
STYLE 10 -.--- 2-7/8 (73,0 mm) DIA. -] RECESSED
ESCUTCHEON RECESSED PENDENT CROSS SECTION
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
\ SURFACE 4 - Bulb 6 - Deflector* on Deflector.
POLY-STAINLESS FINISH ONLY
FIGURE 2
SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS
5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE
2-7/8° (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
TFPI5I
Page 3 of 8
* Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression
is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw
Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector*
SURFACE
1/2
_ _H (12,7 mm)
NOMINAL ~7~I T2
7 mm)
5/16 MAKE-IN I 2-1/4 1-9/16
(39,7 mm) $ (572 mrn)//
3/4' NPT** f WRENCH STYLE 40 b- 2-7/8 (73,0 mm) DIA. -.-.
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT
ALL FINISHES EXCEPT POLY-STAINLESS
CROSS SECTION
UPRIGHT
WRENCH 3/4 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector* on Deflector.
1/2'
(12,7 mm)
NOMINAL
MAKE-IN I 2-5/16
1-9/16' I \\] (58,7 mm)
2-1/4'
(57,2 mm)
H/H
STYLE 40
RECESSED
PENDENT ESCUTCHEON
POLY-STAINLESS FINISH ONLY
FIGURE 3
SERIES TV-B UPRIGHT (TY4151) AND PENDENT (TV4251) SPRINKLERS
8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE
CEILING PLATE 1 - Frame 5 - Compression
SEATING SURFACE 2 - Button Screw
______ 3 - Sealing 6 - Deflector*
Assembly _/ 2-1/4
4 - Bulb
_______
(57,2 mm) 2
* Temperature rating is
1-9/16" 4 indicated on Deflector.
(39,7 mm) I 5 ** Pipe thread connections
per ISO 7-1 can be 6* provided on special
request.
CROSS SECTION
I
fi\ 7/16" I
(11,1 mm) I
NOMINAL I
MAKE-IN
2-3/16'
(55,6 mm)
1/2" NPT** WRENCH
FLATS UPRIGHT PENDENT
FIGURE 4
SERIES TV-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS
8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE
TFPI5I
Page 4 of 8
2-7/8 DIA.
5/8±1/4 (73,0 mm) 3/4' (19,1 mm)
(15,9±6,4 mm 2-1/4" DIA. ) 1/40 (6,4 mm)
FACE OF (57,2 mm) MOUNTING
SPRINKLER PLATE FITTING
1/8°
(3,2 mm)
\?i
MOUNTING
SURFACE
SERIES 1-1/4 (31,8 mm) CLOSURE TV-B 3/4" (19,1 mm)
FIGURE 5
SERIES TY-B RECESSED PENDENT SPRINKLER
ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL
ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT
WRENCH RECESS
(END 'A" USED FOR
1/2' NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 7
W-TYPE 6
SPRINKLER WRENCH
2-7/8' DIA.
5/8±1/4' - (73,0 mm) 3/4" (19,1 mm)
(15,9±6,4 mm) 21/4' DIA 1/4" (6,4 mm)
(57,2 mm) FACE OF I l MOUNTING
SPRINKLER .7) _- PLATE
FITTING I
______ 3,2 mm)
MOUNTING /
SURFACE / ________ ________________ /
CLOSURE SERIES 1-5/16' (33,3 mm)
TV-B 13/16" (20,6 mm)
FIGURE 6
SERIES TY-B RECESSED PENDENT SPRINKLER
ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL
ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 IN. NPT
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 8
W-TYPE 7 RECESSED
SPRINKLER WRENCH
Poly-Stainless
Physical Characteristics
Frame ............................Bronze
Button ................L316 Stainless Steel'
Bulb...............................Glass
Compression Screw .....L316 Stainless Steel'
Deflector ...................Copper/Bronze
Sealing Assembly. Gold Plated Beryllium Nickel
w/TEFLON
'Type L316 stainless steel (UNS 31603) per ASTM
A479/479M or BS EN 1008 WN1.4404.
Operation
The glass bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The TYCO Series TY-B 2.8, 5.6, and
8.0 K-factor, Upright, Pendent, and
Recessed Pendent Sprinklers are
intended for fire protection systems
designed in accordance with the stan-
dard installation rules recognized by
the applicable Listing or Approval
agency, such as UL Listing based on
the requirements of NFPA 13 and FM
Approval based on the requirements
of the FM Global Loss Prevention Data
Sheets. Use only the Style 10 or 40
Recessed Escutcheon, as applicable,
for recessed pendent installations.
Installation
The TYCO Series TY-B 2.8, 5.6, and
8.0 K-factor, Upright, Pendent, and
Recessed Pendent Sprinklers must
be installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 in.
(1,6 mm) for the 135°F (57°C) to
3/32 in. (2,4 mm) for the 360°F (182°C)
temperature ratings.
A leak-tight 1/2 in. NPT sprinkler
joint should be obtained by apply-
ing a minimum-to-maximum torque of
7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain
a leak-tight 3/4 in. NPT sprinkler joint
by applying a minimum to maximum
TFPI5I
Page 5 of 8
K Sprinkler
Type
Temperature
Rating
Bulb
Liquid
Color
Sprinkler Finish8
Natural
Brass
I Chrome
Plated Polyesterc PolyStainlessc Lead
Coated
I Wax
Coated
I Wax-Over-
Lead
Coated
135°F (57°C) Orange
2.8
NPT
Upright
(TY1151)
and
Pendent
(TY1251)
1, 2, 3 N/A N/Ad
155°F (68°C) Red
° (79* 175F (79C) C) Yellow
200°F (93°C) Green
286°F (141°C) Figure 1 Blue
360°F (182°C) Mauve 1,2
_
135°F (57°C) Orange
5.6
Upright
(TY3151)
and
Pendent
(TY3251)
Figure 2
1,2,3,4,5,6,7
I
1,2 1,2,3,5
1,2,3,5 1,2,3,5 155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue ib, 2b, 3b, 5b ib, 2b, 3b, 5b
360°F (182°C) Mauve N/A 1/2 in.
NPT 135°F (57°C) Orange
155°F (68°C) Red Recessed
Pendent
(TY3251)a
1,2,3,4,5
1,2 N/A 175'F (79'C) Yellow
200°F (93°C) Green Figure 5
286°F (141°C) Blue 1,2
135°F (57°C) Orange
Upright
(TY4151)
and
Pendent
(TY4251)
155°F (68°C) Red
1,2,3,4,5,6,7 1,2 1,2,5
1,2,3,5 1,2,5 175°F (79°C) Yellow
200° F (93°C) Green
286°F (141°C) Blue lb, 2b, 3b, 5b ib, 2b, 5b
8.0 Figure 3
360°F (182°C) Mauve N/A 3/4 in.
NPT 135°F (57°C) Orange
155°F (68°C) Red Recessed
Pendent
(TY4251)a
1,2,3,4,5 1,2 N/A 175°F (79°C) Yellow
200°F (93°C) Green Figure 6
286°F (141°C) Blue 1,2
135°F (57°C) Orange
155°F (68°C) Red
8.0
1/21n.
NPT
Upright
(TY4851)
and
Pendent
(TY4951)
1,2,3,4,5,6 N/A N/A
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue Figure 4
360°F (182°C) Mauve
NOTES
Listed by Underwriters Laboratories, Inc. (UL).
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
Approved by FM Global (FM Approvals).
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03).
Approved by the City of New York under MEA 354-01-E.
VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377)
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05)
Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as
Corrosion-Resistant Sprinklers.
Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable
150'F (66'C) maximum ceiling temperature
Frame and deflector only
Not Applicable (N/A)
TABLE A
SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS
LABORATORY LISTINGS AND APPROVALS
TFPI5I
Page 6 of 8
Sprinkler Finish
K Type
Natural Brass Chrome
I
Pol Lead
Plated yester' Wax Wax-Over-Lead
Coated Coated Coated
2.8 Upright (TY115I)
1/2 in. and 175 psi (12,1 bar) N/A3
NPT Pendent (TY1251)
Upright (TY3151)
and
5.6 Pendent (TY3251) 250 psi (17,2 bar)2
1/2 in. or NPT 175 psi (12,1 bar)
Recessed Pendent
(TY3251)
Upright (TY4151)
and 175 psi (12,1 bar)
8.0 Pendent (TY4251) 3/4 in
NPT
Rece ,d251)
Peident 175 psi (12,1 bar) N/A
8.0 Upright (TY4851)
1/2 in. and 175 psi (12,1 bar)
NPT Pendent (TY4951)
NOTES
Frame and deflector only
The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in
Canada (C-UL), and the Approval by the City of New York.
Not Applicable (N/A)
TABLE B
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
MAXIMUM WORKING PRESSURE
torque of 10 to 20 lb-ft (13,4 to
26,8 N•m). Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in the escutch-
eon plate by under- or over-tightening
the sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Series TV-B Upright and Pendent
Sprinklers Installation
The Series TY-B Upright and Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step 1. Install pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 7).
For wax-coated sprinklers, use an
8 or 10 in. adjustable wrench. With
reference to Figure 1 to 4, apply the
W-Type 6 Recessed Sprinkler Wrench
or an adjustable wrench, as applicable,
to the sprinkler wrench flats.
Wax Coated Sprinklers
When installing wax-coated sprinklers
with an adjustable wrench, take care to
prevent damage to the wax coating on
the sprinkler wrench flats or frame arms
and, consequently, exposure of bare
metal to the corrosive environment:
Open the jaws of the wrench suffi-
ciently wide to pass over the wrench
flats without damaging the wax
coating.
Before wrench tightening the sprin-
kler, adjust the jaws of the wrench
to contact only the sprinkler wrench
flats.
After wrench tightening the sprin-
kler, loosen the wrench jaws before
removing the wrench.
After Installation
After installation, complete the
following:
Inspect the sprinkler wrench flats
and frame arms and retouch (repair)
the wax coating whenever the coat-
ing has been damaged and bare
metal is exposed.
Retouch the wax coating on the
wrench flats by gently applying a
heated 1/8 inch diameter steel rod
to the damaged areas of wax, to
smooth it back over areas where
bare metal is exposed.
NOTICE
Only retouching of the wax coating
applied to the wrench flats and frame
arms is permitted, and the retouching
is to be performed only at the time of
the initial sprinkler installation.
The steel rod should be heated only to
the point it can begin to melt the wax,
and appropriate precautions need to be
taken when handling the heated rod in
order to prevent the installer from being
burned.
TFPI5I
Page 7 of 8
Series TV-B Recessed Pendent
Sprinklers
The Series TV-B Recessed Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step 1. After installing the Style 10
or 40 Mounting Plate, as applicable,
over the sprinkler threads and with
pipe thread sealant applied to the pipe
threads, hand-tighten the sprinkler into
the sprinkler fitting.
Step 2. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 8). With reference to Figure 3 or
4, apply the W-Type 7 Recessed Sprin-
kler wrench to the sprinkler wrench
flats.
Step 3. After the ceiling is installed or
the finish coat is applied, slide on the
Style 10 or 40 Closure over the Series
TV-B Recessed Pendent Sprinkler
and push the Closure over the Mount-
ing Plate until its flange contacts the
ceiling.
Care and
Maintenance
The TYCO Series TV-B 2.8, 5.6, and
8.0 K-factor, Upright, Pendent, and
Recessed Pendent Sprinklers must be
maintained and serviced in accordance
with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
system from the proper authorities
and notify all personnel who may be
affected by this action.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Absence of an escutcheon, which is
used to cover a clearance, may delay
the time to sprinkler operation in a fire
situation.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. Refer to the Instal-
lation Section.
The owner is responsible for the
inspection, testing, and maintenance
of their fire protection system and
devices in compliance with this doc-
ument, as well as with the applicable
standards of the National Fire Protec-
tion Association, (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. Contact
the installing contractor or product
manufacturer with any questions.
Automatic sprinkler are recommended
to be inspected, tested, and maintained
by a qualified Inspection Service in
accordance with local requirements
and/or national codes.
TFPI5I
Page 8 of 8
S
P/N 57 - XXX - X - XXX
SIN F SPRINKLER TEMPERATURE
FINISH RATING
530 2.8K UPRIGHT (1/2 in. NPT) TY1151
531 2.8K PENDENT (1/2 in. NPT) TY1251
570 5.6K UPRIGHT (1/2 in. NPT) TY3151
571 5.6K PENDENT (1/2 in. NPT) TY3251
590 8.0K UPRIGHT (3/4 in. NPT) TY4151
591 8.0K PENDENT (3/4 in. NPT) 1Y4251
560 8.0K UPRIGHT (1/2 in. NPT) TY4851
561 8.0K PENDENT (1/2 in. NPT) TY4951
1 NATURAL BRASS
ALUMINUM (RAL9007)1
PURE WHITE (RAL9010)2
SIGNAL WHITE (RAL9003)
JET BLACK (RAL9005)3
WAX COATED
LEAD COATED
135 135°F (57°C)
2
POLY-STAINLESS GREY
POLYESTER
155 155°F (68°C)
175 175-F (79-C)
POLYESTER 200 200°F (93°C)
POLYESTER 286 286°F (141°C)
POLYESTER 360 360°F (182°C)
6 286°F (141°C) MAX 000 OPEN4
7
I WAX-OVER-LEAD
286°F (141-C) MAX
9 1 CHROME PLATED
NOTES
Only available on TY3151, TY3251, TY4151, and TY4251.
Eastern Hemisphere sales only.
Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture.
Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ('OPEN' indicates sprinkler assembly without glass bulb, button, and sealing assembly).
TABLE C
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with
NPT Thread Connections
Specify: Series TY-B (specify SIN),
(specify K-factor), (specify Upright
or Pendent) Sprinkler with (specify)
temperature rating, (specify) finish or
coating, P/N (Refer to Table C)
Recessed Escutcheon
Specify: Style (10 or 40) Recessed
Escutcheon with (specify*) finish, P/N
(specify*)
Refer to Technical Data Sheet TFP770
Sprinkler Wrenches
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
Wax Sticks (for retouching wrench-
damaged wax coating)
Specify: (specify color, below) Color-
coded Wax Sticks for retouching
(specify temperature rating) tempera-
ture-rated Series TY-B Sprinklers, P/N
(specify)
Black for 135°F (57°C) ......P/N 56-065-1-135
Red for 155°F (68°C) .......P/N 56-065-1-155
Yellow for 175°F (79°C) .....P/N 56-065-1-175
Blue for 200°F (93°C)
and 286°F (141°C) .........P/N 56-065-1-
286
Note: Each wax stick is suitable for
retouching up to 25 sprinklers.
The wax used for 286°F (141°C) sprinklers
is the same as for200°F (93°C) sprinklers.
Therefore, the 286°F (141°C) sprinkler
is limited to the same maximum ceiling
temperature as the 200°F (93°C) sprinkler
which is 150°F (66°C).
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700
Alt, 02018 Johnson Controls. All rights roserned. All specIfications and other Information shown were current as of dncument reoisinn date and are sublectto changewahos notice. Johnson
NATNAL FE PROTECTN AS5OcI4TN and NFPA aro rn5istorcd tradernorke t huticnulFtro Prctnrtion Association; Controls TEFLON isa registered trademark of Dupont