Loading...
HomeMy WebLinkAbout1 LEGOLAND DR; ; FPC2020-0027; PermitCL7city of PERMIT REPORT Carlsbad Print Date: 12/02/2020 Permit No: FPC2020-0027 Job Address: 1 LEGOLAND DR, CARLSBAD, CA 92008-4610 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2111000900 Track #: Applied: 02/10/2020 Valuation: $89,248.88 Lot #: Issued: 02/13/2020 Occupancy Group: Project #: Finaled Close Out: 03/12/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: WOK & BOWL (LEGOLAND) -SPRINKLER TI (2 HEADS) Applicant: FPContractor: A AND D FIRE SPRINKLERS INC A AND D FIRE SPRINKLERS INC TREVOR TORRES 7130 CONVOY CT 7130 CONVOY CT SAN DIEGO, CA 92111-1019 SAN DIEGO, CA 92111-1019 (858) 277-3473 (858) 277-3473 FEE AMOUNT FIRE NFPA 13 or 13R System 6 heads or less $125.00 Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov C- tqco® Worldwide Contacts I www.tyco-fire.com Series TYB - 2.8,1 5.6., and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in herein are standard response, standard coverage, decora- tive 5 mm glass bulb-type spray sprin- klers. They are designed for use in light, ordinary, or extra-hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The TY-B Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjust- ment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE, The Series TY-B 2.8, 5.6, and 8.0 K-fac- tor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contract the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Numbers (SIN) TY1151 ... Upright 2.8K, 1/2 in. NPT TY1251 . . .Pendent 2.8K, 1/2 in. NPT TY3151 ... Upright 5.6K, 1/2 in. NPT fTY3251 . . .Pendent 5.6K, 1/2 in. NPT TY4151 ... Upright 8.OK, 3/4 in.-NPT---' TY4251 . . .Pendent 8.0K, 3/4 in. NPT TY4851 ... Upright 8.01K, 1/2 in. NPT TY4951 . . .Pendent 8.01K, 1/2 in. NPT JULY 2018 Technical Data Approvals UL and C-UL Listed FM, LPCB, VdS, and NYC Approved Refer to Table A for complete approval infor-mation, including corrosion-resistant status. Maximum Working Pressure Refer to Table B Discharge Coefficient K=2.8 GPM/psi½ (40,3 LPM/bar) K=5.6 GPM/psi" (80,6 LPM/bar½) K=8.0 GPM/psi/2 (115,2 LPM/bar") Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector .........................Copper Bushing (K=2.8) ....................Bronze TFPISI 1/2 NPT* UPRIGHT CROSS SECTION RECESSED PENDENT PENDENT UPRIGHT 7/16 1,1 mm) OMINAL lAKE-IN 2-3/16 (55,6 mm) 2-3/16 (55,6 mm) 1-1/2 (38,1 mm) STYLE 1( RECESSEL.J ESCUTCHEON TFPI5I Page 2 of 8 CEILING PLATE SEATING SURFACE -/7 nm) 1 - Frame 5 - Compression 2 - Button Screw 7 3 - Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 - Bulb 2 * Temperature rating is I I indicated on Deflector. II 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. I i 7/16' (11,1 mm) NOMINAL MAKE-IN I 2-3/16 _____ (55,6 mm) 1/2" NPT** / WRENCH FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on ESCUTCHEON special request. PLATE SEATING SURFACE ______________________ _____________________________________ _ L1/2 H 7/16" ______ mm) 11,1 mm) OMINAL 6 MAKE-IN _j I 23/16U,/,,/ (55,6 mm) _______ t WRENCH FLATS PENDENT 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* / I\ fl 2 4 -5 STYLE 10 -.--- 2-7/8 (73,0 mm) DIA. -] RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE 2-7/8° (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI5I Page 3 of 8 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 _ _H (12,7 mm) NOMINAL ~7~I T2 7 mm) 5/16 MAKE-IN I 2-1/4 1-9/16 (39,7 mm) $ (572 mrn)// 3/4' NPT** f WRENCH STYLE 40 b- 2-7/8 (73,0 mm) DIA. -.-. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS CROSS SECTION UPRIGHT WRENCH 3/4 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1/2' (12,7 mm) NOMINAL MAKE-IN I 2-5/16 1-9/16' I \\] (58,7 mm) 2-1/4' (57,2 mm) H/H STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TV-B UPRIGHT (TY4151) AND PENDENT (TV4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw ______ 3 - Sealing 6 - Deflector* Assembly _/ 2-1/4 4 - Bulb _______ (57,2 mm) 2 * Temperature rating is 1-9/16" 4 indicated on Deflector. (39,7 mm) I 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. CROSS SECTION I fi\ 7/16" I (11,1 mm) I NOMINAL I MAKE-IN 2-3/16' (55,6 mm) 1/2" NPT** WRENCH FLATS UPRIGHT PENDENT FIGURE 4 SERIES TV-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE TFPI5I Page 4 of 8 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm 2-1/4" DIA. ) 1/40 (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8° (3,2 mm) \?i MOUNTING SURFACE SERIES 1-1/4 (31,8 mm) CLOSURE TV-B 3/4" (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT WRENCH RECESS (END 'A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH 2-7/8' DIA. 5/8±1/4' - (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 21/4' DIA 1/4" (6,4 mm) (57,2 mm) FACE OF I l MOUNTING SPRINKLER .7) _- PLATE FITTING I ______ 3,2 mm) MOUNTING / SURFACE / ________ ________________ / CLOSURE SERIES 1-5/16' (33,3 mm) TV-B 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel' Bulb...............................Glass Compression Screw .....L316 Stainless Steel' Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON 'Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the Style 10 or 40 Recessed Escutcheon, as applicable, for recessed pendent installations. Installation The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum TFPI5I Page 5 of 8 K Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish8 Natural Brass I Chrome Plated Polyesterc PolyStainlessc Lead Coated I Wax Coated I Wax-Over- Lead Coated 135°F (57°C) Orange 2.8 NPT Upright (TY1151) and Pendent (TY1251) 1, 2, 3 N/A N/Ad 155°F (68°C) Red ° (79* 175F (79C) C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F (182°C) Mauve 1,2 _ 135°F (57°C) Orange 5.6 Upright (TY3151) and Pendent (TY3251) Figure 2 1,2,3,4,5,6,7 I 1,2 1,2,3,5 1,2,3,5 1,2,3,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue ib, 2b, 3b, 5b ib, 2b, 3b, 5b 360°F (182°C) Mauve N/A 1/2 in. NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3251)a 1,2,3,4,5 1,2 N/A 175'F (79'C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F (57°C) Orange Upright (TY4151) and Pendent (TY4251) 155°F (68°C) Red 1,2,3,4,5,6,7 1,2 1,2,5 1,2,3,5 1,2,5 175°F (79°C) Yellow 200° F (93°C) Green 286°F (141°C) Blue lb, 2b, 3b, 5b ib, 2b, 5b 8.0 Figure 3 360°F (182°C) Mauve N/A 3/4 in. NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4251)a 1,2,3,4,5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red 8.0 1/21n. NPT Upright (TY4851) and Pendent (TY4951) 1,2,3,4,5,6 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F (182°C) Mauve NOTES Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by FM Global (FM Approvals). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable 150'F (66'C) maximum ceiling temperature Frame and deflector only Not Applicable (N/A) TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 6 of 8 Sprinkler Finish K Type Natural Brass Chrome I Pol Lead Plated yester' Wax Wax-Over-Lead Coated Coated Coated 2.8 Upright (TY115I) 1/2 in. and 175 psi (12,1 bar) N/A3 NPT Pendent (TY1251) Upright (TY3151) and 5.6 Pendent (TY3251) 250 psi (17,2 bar)2 1/2 in. or NPT 175 psi (12,1 bar) Recessed Pendent (TY3251) Upright (TY4151) and 175 psi (12,1 bar) 8.0 Pendent (TY4251) 3/4 in NPT Rece ,d251) Peident 175 psi (12,1 bar) N/A 8.0 Upright (TY4851) 1/2 in. and 175 psi (12,1 bar) NPT Pendent (TY4951) NOTES Frame and deflector only The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. Not Applicable (N/A) TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE torque of 10 to 20 lb-ft (13,4 to 26,8 N•m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TV-B Upright and Pendent Sprinklers Installation The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7). For wax-coated sprinklers, use an 8 or 10 in. adjustable wrench. With reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, to the sprinkler wrench flats. Wax Coated Sprinklers When installing wax-coated sprinklers with an adjustable wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprin- kler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod in order to prevent the installer from being burned. TFPI5I Page 7 of 8 Series TV-B Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, apply the W-Type 7 Recessed Sprin- kler wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TV-B Recessed Pendent Sprinkler and push the Closure over the Mount- ing Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TV-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFPI5I Page 8 of 8 S P/N 57 - XXX - X - XXX SIN F SPRINKLER TEMPERATURE FINISH RATING 530 2.8K UPRIGHT (1/2 in. NPT) TY1151 531 2.8K PENDENT (1/2 in. NPT) TY1251 570 5.6K UPRIGHT (1/2 in. NPT) TY3151 571 5.6K PENDENT (1/2 in. NPT) TY3251 590 8.0K UPRIGHT (3/4 in. NPT) TY4151 591 8.0K PENDENT (3/4 in. NPT) 1Y4251 560 8.0K UPRIGHT (1/2 in. NPT) TY4851 561 8.0K PENDENT (1/2 in. NPT) TY4951 1 NATURAL BRASS ALUMINUM (RAL9007)1 PURE WHITE (RAL9010)2 SIGNAL WHITE (RAL9003) JET BLACK (RAL9005)3 WAX COATED LEAD COATED 135 135°F (57°C) 2 POLY-STAINLESS GREY POLYESTER 155 155°F (68°C) 175 175-F (79-C) POLYESTER 200 200°F (93°C) POLYESTER 286 286°F (141°C) POLYESTER 360 360°F (182°C) 6 286°F (141°C) MAX 000 OPEN4 7 I WAX-OVER-LEAD 286°F (141-C) MAX 9 1 CHROME PLATED NOTES Only available on TY3151, TY3251, TY4151, and TY4251. Eastern Hemisphere sales only. Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ('OPEN' indicates sprinkler assembly without glass bulb, button, and sealing assembly). TABLE C SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench- damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1- 286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F (141°C) sprinklers is the same as for200°F (93°C) sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler which is 150°F (66°C). 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Alt, 02018 Johnson Controls. All rights roserned. All specIfications and other Information shown were current as of dncument reoisinn date and are sublectto changewahos notice. Johnson NATNAL FE PROTECTN AS5OcI4TN and NFPA aro rn5istorcd tradernorke t huticnulFtro Prctnrtion Association; Controls TEFLON isa registered trademark of Dupont