HomeMy WebLinkAbout1 LEGOLAND DR; ; FPC2017-0132; PermitPERMIT REPORT
craty of
Carlsbad
Print Date: 12/02/2020 Permit No: FPC2017-0132
Job Address: 1 LEGOLAND DR, CARLSBAD, CA 92008-4610 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class:
Parcel #: 2111000900 Track #:
Valuation: $120,000.00 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check #:
Fire Alarm
Applied: 05/18/2017
Issued: 06/22/2017
DEV2016-0028 Finaled Close Out: 12/02/2020
Inspector:
Final Inspection:
Project Title: LEGOLAND WP17 WATER SLIDE
Description: LEGOLAND WATER SLIDE -FIRE ALARM
Applicant: FPContractor:
PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC
CHARLES KRETZING 15531 CONTAINER LN
5115 AVENIDA ENCINAS, #G HUNTINGTON BEACH, CA 92649-1530
CARLSBAD, CA 92008-4387 (714) 902-8000
(760) 930-60.14
FEE AMOUNT
FIRE TI Fire Alarm System $601.00
Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov
Pc- 2o 1- - 0 1 3 2
Pyro-Comm Systems, Inc.
5115 Avenida Encinas, Suite G C10#612153
Carlsbad, CA 92008 (760) 930-6014 Fax (760) 930-6015
Fire Alarm System Submittal
Legoland WP17 Water Slide
MFG. MODEL # DESCRIPTION CSFM
Notifier FMM-1 Monitor Module 7300-0028:219
Notifier FDM-1 Dual Monitor Module 7300-0028:219
05/16/17 Job #2017222
DN-6720:C • H-220
FMM-1 (A), FMM.1 01(A),
FZM.1 (A) & FDM-1 (A)
Monitor Modules with FlashScan®
General
Four different monitor modules are available for Notifier's intel-
ligent control panels for a variety of applications. Monitor mod-
ules supervise a circuit of dry-contact input devices, such as
conventional heat detectors and pull stations, or monitor and
power a circuit of two-wire smoke detectors (FZM-1 (A)).
FMM-1(A) is a standard-sized module (typically mounts to a 4
[10.16 cm] square box) that supervises either a Style D (Class
or Style B (Class B) circuit of dry-contact input devices.
FMM-101(A) is a miniature monitor module a mere 1.3' (3.302
cm) H x 2.75' (6.985 cm) W x 0.5' (1.270 cm) D that super-
vises a Style B (Class B) circuit of dry-contact input devices.
Its compact design allows the FMM-101(A) to be mounted in a
single-gang box behind the device it monitors.
FZM-1(A) is a standard-sized module that monitors and super-
vises compatible two-wire, 24 volt, smoke detectors on a Style
D (Class A) or Style B (Class B) circuit.
FDM-1(A) is a standard-sized dual monitor module that moni-
tors and supervises two independent two-wire Style B (Class
dry-contact initiating device circuits (lDCs) at two separate,
consecutive addresses in intelligent, two-wire systems.
FlashScan® (U.S. Patent 5,539,389) is a communication pro-
tocol developed by NOTIFIER that greatly increases the speed
of communication between analog intelligent devices. Intelli-
gent devices communicate in a grouped fashion. If one of the
devices within the group has new information, the panel CPU
stops the group poll and concentrates on single points. The
net effect is response speed greater than five times that of
other designs.
FMM.1 (A) Monitor Module
Built-in type identification automatically identifies this device
as a monitor module to the control panel.
Powered directly by two-wire SLC loop. No additional power
required.
High noise (EMF/RFI) immunity.
SEMS screws with clamping plates for ease of wiring.
Direct-dial entry of address: 01 - 159 on FlashScan loops;
01 —99 on CLIP loops.
LED flashes green during normal operation (this is a pro-
grammable option) and latches on steady red to indicate
alarm.
The FMM-1(A) Monitor Module is intended for use in intelli-
gent, two-wire systems, where the individual address of each
module is selected using the built-in rotary switches. It pro-
vides either a two-wire or four-wire fault-tolerant Initiating
Device Circuit (IDC) for normally-open-contact fire alarm and
supervisory devices. The module has a panel-controlled LED
indicator. The FMM-1 (A) can be used to replace MMX-1 (A)
modules in existing systems.
F114114-1(A) APPLICATIONS
Use to monitor a zone of four-wire smoke detectors, manual
fire alarm pull stations, waterflow devices, or other normally-
open dry-contact alarm activation devices. May also be used
to monitor normally-open supervisory devices with special
supervisory indication at the control panel. Monitored circuit
may be wired as an NFPA Style B (Class B) or Style 0 (Class
NOTIFIER®
by Honeywell
nSUPAIl s.mc,.._A..c
FMM-1(A) (Type H)
A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor
(provided) terminates the Style B circuit. No resistor is
required for supervision of the Style D circuit.
FMM-1(A) OPERATION
Each FMM-1 (A) uses one of the available module addresses
on an SLC loop. It responds to regular polls from the control
panel and reports its type and the status (open/normal/short)
of its Initiating Device Circuit (IDC). A flashing LED indicates
that the module is in communication with the control panel.
The LED latches steady on alarm (subject to current limita-
tions on the loop).
FMM-1(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Maximum current draw: 5.0 mA (LED on).
Average operating current: 350 pA (LED flashing), 1 com-
munication every 5 seconds, 47k EOL.
Maximum IDC wiring resistance: 40 ohms.
EOL resistance: 47K ohms.
Temperature range: 32°F to 120°F (0°C to 490C).
Humidity range: 10% to 93% noncondensing.
Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125' (5.398 cm) deep box.
DN-6720:C • 10/06/2010 - Page 1 of 4
I
I
I
I
FMM-1 01(A) Mini Monitor Module
Built-in type identification automatically identifies this device
as a monitor module to the panel.
Powered directly by two-wire SLC loop. No additional power
required.
High noise (EMF/RFl) immunity.
Tinned, stripped leads for ease of wiring.
Direct-dial entry of address: 01 - 159 on FlashScan loops;
01 —99 on CLIP loops.
1415 0 1 ADDRESS I 0 1
I 1
LOOP
0~ " 8 76 8 76 ho LIII
TENS ONES
The FMM-101(A) Mini Monitor Module can be installed in a
single-gang junction directly behind the monitored unit. Its
small size and light weight allow it to be installed without rigid
mounting. The FMM-101(A) is intended for use in intelligent,
two-wire systems where the individual address of each module
is selected using rotary switches. It provides a two-wire initiat-
ing device circuit for normally-open-contact fire alarm and
security devices. The FMM-1 01(A) can be used to replace
MMX-101(A) modules in existing systems.
FMM-101(A) APPLICATIONS
Use to monitor a single device or a zone of four-wire smoke
detectors, manual fire alarm pull stations, waterflow devices, or
other normally-open dry-contact devices. May also be used to
monitor normally-open supervisory devices with special super-
visory indication at the control panel. Monitored circuit/device
is wired as an NFPA Style B (Class B) Initiating Device Circuit.
A 47K ohm End-of-Line Resistor (provided) terminates the cir-
cuit.
FMM-101(A) OPERATION
Each FMM-101(A) uses one of the available module
addresses on an SLC loop. It responds to regular polls from
the control panel and reports its type and the status (open/nor-
mal/short) of its Initiating Device Circuit (IDC).
FMM-101(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Average operating current: 350 pA, 1 communication every
5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC
Shorted).
Maximum IDC wiring resistance: 40 ohms.
Maximum IOC Voltage: 11 Volts.
Maximum IDC Current: 400 pA.
EOL resistance: 47K ohms.
Temperature range: 32°F to 120°F (0°C to 49°C).
Humidity range: 10% to 93% noncondensing.
Page 2 of 4— ON-6720:C • 10/06/2010
Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x
0.65° (1.651 cm) deep.
Wire length: 6(15.24cm) minimum.
FZM..1 (A) Interface Module
Supports compatible two-wire smoke detectors.
Supervises IDC wiring and connection of external power
source.
High noise (EMF/RFI) immunity.
SEMS screws with clamping plates for ease of wiring.
Direct-dial entry of address: 01 - 159 on FlashScan loops,
01 —99 on CLIP loops.
LED flashes during normal operation; this is a programma-
ble option.
LED latches steady to indicate alarm on command from
control panel.
The FZM-1(A) Interface Module is intended for use in intelli-
gent, addressable systems, where the individual address of
each module is selected using built-in rotary switches. This
module allows intelligent panels to interface and monitor two-
wire conventional smoke detectors. It transmits the status (nor-
mal, open, or alarm) of one full zone of conventional detectors
back to the control panel. All two-wire detectors being moni-
tored must be UL compatible with the module. The FZM-1(A)
can be used to replace MMX-2(A) modules in existing sys-
tems.
FZM-1(A) APPLICATIONS
Use the FZM-1 (A) to monitor a zone of two-wire smoke detec-
tors. The monitored circuit may be wired as an NFPA Style B
(Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K
ohm End-of-Line Resistor (provided) terminates the end of the
Style B or D (class B or A) circuit (maximum IDC loop resis-
tance is 25 ohms). Install ELR across terminals 8 and 9 for
Style D application.
FZM-1(A) OPERATION
Each FZM-1(A) uses one of the available module addresses
on an SLC loop. It responds to regular polls from the control
panel and reports its type and the status (open/normal/short)
of its Initiating Device Circuit (IDC). A flashing LED indicates
that the module is in communication with the control panel.
The LED latches steady on alarm (subject to current limita-
tions on the loop).
FZM-1(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Maximum current draw: 5.1 mA (LED on).
Maximum IDC wiring resistance: 25 ohms.
Average operating current: 300 pA, 1 communication and 1
LED flash every 5 seconds, 3.9k eol.
EOL resistance: 3.91K ohms.
External supply voltage (between Terminals T3 and T4):
DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms
maximum. Current: 90 mA per module maximum.
Temperature range: 32°F to 120°F (0°C to 490C).
Humidity range: 10% to 93% noncondensing.
Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x
1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x
2.125 (5.398 cm) deep box.
I
F
I
I
0111w IIj JH 0
-.jll 110 •
I
H
LH HF
FDM I(A) Dual Monitor Module
I The FDM-1 (A) Dual Monitor Module is intended for use in intelli-
gent, two-wire systems. It provides two independent two-wire
initiating device circuits (lDCs) at two separate, consecutive
I
addresses. It is capable of monitoring normally open contact fire
alarm and supervisory devices; or either normally open or nor-
mally closed security devices. The module has a single panel-
controlled LED.
NOTE: The FDM- 1(A) provides two Style B (Class B) lDC circuits
I ONLY. Style D (Class A) IDC circuits are NOT supported in any
application.
FDM-1(A) SPECIFICATIONS
I
Normal operating voltage range: 15 to 32 VDC.
Maximum current draw: 6.4 mA (LED on).
Average operating current: 750 pA (LED flashing).
I
Maximum IDC wiring resistance: 1,500 ohms.
Maximum IDC Voltage: 11 Volts.
Maximum IDC Current: 240 pA
I
EOL resistance: 47K ohms.
Maximum SLC Wiring resistance: 40 Ohms.
Temperature range: 320 to 120°F (0° to 49°C).
I
Humidity range: 10% to 93% (non-condensing).
Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x
2.125" (5.398 cm) deep.
FDM-1(A) AUTOMATIC ADDRESSING
I The FDM-1 (A) automatically assigns itself to two addressable
points, starting with the original address. For example, if the
FDM-1(A) is set to address "26", then it will automatically
I
assign itself to addresses "26" and 27".
NOTE: "Ones" addresses on the FDM-1(A) are 0,2, 4, 6, 0r8 only.
Terminals 6 and 7 use the first address, and terminals 8 and 9 use
the second address.
I A CAUTION:
Avoid duplicating addresses on the system.
Installation
FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly
to a standard 4' (10.16 cm) square, 2.125" (5.398 cm) deep,
electrical box. They may also be mounted to the SMB500 sur-
face-mount box. Mounting hardware and installation instruc-
tions are provided with each module. All wiring must conform
to applicable local codes, ordinances, and regulations. These
modules are intended for power-limited wiring only.
The FMM-101(A) module is intended to be wired and mounted
without rigid connections inside a standard electrical box. All
wiring must conform to applicable local codes, ordinances, and
regulations.
Agency Listings and Approvals
In some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
UL: S635
ULC: S635
FM Approved
CSFM: 7300-0028:0219
MEA: 457-99-E
U.S. Coast Guard:
DN-6720:C • 10/06/2010 - Page 3 of 4
I
I
- 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1)
- 161.002/42/1 (NFS-640: FMM- 11-101)
Lloyd's Register:
—03/60011/El (FMM-1I-101, FZM-1)
- 94/60004/E2 (AFP-200: except FDM- 1)
—02/60007 (NFS -640: FDM- 1)
FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058
(NFS2-3030)
Product Line Information
NOTE: "A" suffix indicates ULC-listed model.
FMM-1(A): Monitor module.
FMM.1 01 (A): Monitor module, miniature.
FZM-1(A): Monitor module, two-wire detectors.
FDM-1(A): Monitor module, dual, two independent Class B cir-
cuits.
SMB500: Optional surface-mount backbox.
NOTE: See installation instructions and refer to the SLC Wiring
Manual, PN 51253.
FlashScan® and NOTIFIER® are registered trademarks and FireWatch is
a trademark of Honeywell International Inc.
@2010 by Honeywell International Inc. All rights reserved. Unauthorized use I of this document is strictly prohibited.
I iso ooi This document is not intended to be used for installation purposes.
RM
We try to keep our product information up-to-date and accurate.
• We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
QUALITY SYSTEMS Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. I www.notifier.com
Page 4 of 4— DN-6720:C • 10/06/2010
I
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7300-0028:0219 Page 1 of 1
CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES
I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653
Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309
I
Email: vladimir.kireyevhoneywell.com
DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor
module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1,
FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRMI with 2 input/2 output
I relay module. All devices are intended to be connected between the signaling line circuit of a
compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product
description and operational considerations.
I RATING: 16-33 VDC Primary
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
I and in manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, product number and UL label.
APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm
I control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640
(CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No.
7165-0028:224) Fire Alarm Control Units.
I NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power
supply is referenced to the negative of the auxiliary supply of the compatible control panel.
This is done in order to detect ground faults on the initiating circuit.
*Rev. 10-24-11 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2016 Listing Expires June 30, 2017
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division