HomeMy WebLinkAbout1 LEGOLAND DR; ; FPC2018-0021; PermitPERMIT REPORT C liLcity of arlsbad Print Date: 12/02/2020 Permit No: FPC2018-0021 Job Address: 1 LEGOLAND DR, CARLSBAD, CA 92008-4610 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2111000900 Track #: Applied: 01/17/2018 Valuation: $120,000.00 Lot #: Issued: 02/01/2018 Occupancy Group: Project #: DEV2016-0028 Finaled Close Out: 12/02/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: LEGOLAND WP17 WATER SLIDE Description: LEGOLAND WP17 RESTROOM -FIRE ALARM TI Applicant: FPContractor: PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC CHARLES KRETZING 15531 CONTAINER LN 5115 AVENIDA ENCINAS, # G HUNTINGTON BEACH, CA 92649-1530 CARLSBAD, CA 92008-4387 (714) 902-8000 (760) 930-6014 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 -- Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov F FC 2-c) 19 -oo2.i Pyro-Comm Systems, Inc. 5115 Avenida Encinas, Suite G C10 #612153 Carlsbad, CA 92008 (760) 930-6014 Fax (760) 930-6015 City of Carlsbad Legoland WP 17 Restroom Fire Alarm System Submittal MFG. MODEL # DESCRIPTION CSFM Notifier FCPS-24S8 Power Supply 7315-0028:0225 Notifier BAT-1270 Batteries N/A Notifier FSP-851 Smoke Det. Photo 7272-0028:0206 Notifier B21OLP Bases 7300-1653:0109 Notifier FCM-1 Control Module 7300-0028:0219 Notifier FDM-1 Monitor Module 7300-0028:0219 Sys. Sensor PC2WL Ceiling Horn/Strobe 7135-1653:0503 01/15/18 Job #2018017 dn-6927:a FPS-24S6(C/E) &FCPS-1 124S8(CIE) 6- & 8-Amp 24-Volt Remote Power Supplies NOTIFIER® by Honeywell General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FGPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAG) expansion (to support ADA requirements and NAG syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDG power to four notification appliance circuits configured as either four Glass B (Style Y) or Glass A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FGPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FGPS-2456G & FGPS-24S8G are ULG-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAG synchronization using System Sensor, Wheelock, or Gentex "Gommander2" appliances. Operates as a sync-follower' or as a sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FAGP NAG (NAG expander mode) or jumped perma- nently ON" (stand-alone mode). Four Glass B (Style Y) or four Glass A (Style Z, with ZNAG-4 module) NAGs. 6-amp (FGPS-2456) or 8-amp (FGPS-2458) full load out- put, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp (FGPS-2456) or 6-amp (FGPS-2458) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FAGP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering tour-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-G normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AG trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDG. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FGPS-2456G/-2458G: 120 VAC, 60 Hz, 3.2A maximum. FGPS-24S6E/-2458E: 240 VAG, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16 -32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDG. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDG filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FGPS-2456: 4.0 A maximum. - FGPS-2458: 6.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FGPS-24S6: 6.0 A maximum. - FGPS-2458: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDG. dn-6927:a • 04/30/09 - Page 1 of 2 I I U I I Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-2458). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACR When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e. follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-24S8 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator' mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-24S8C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS- 8.0 A, 120 VAC remote charger power supply. 'Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [Cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 933=1 • We cannot cover all specific applications or anticipate all requirements. minmo ammmmms All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6927:a • 04/30/09 I Li 1 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:0225 \ CATEGORY: 7315— POWER UNITS Page 1 of I LISTEE: NotiflerOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models FCPS-24S6 power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-O3KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I 1 I BAT Series Batteries Sealed Lead-Acid General BAT Series Batteries are Power Sonic brand batteries. BAT Series (or Power Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS, polystyrene, or polypropylene, depending on models). Long service life. Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH20845 (Power-Sonic) DN-6933:C1 • E-205 NOTIFIER® by Honeywell 6933c0v.jpg Ordering Information BAT-12507BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH) -- JBAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH) "BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH) BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH) BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH) BAT-12550: single battery (12 V 55 AH) BAT-121 000: single battery (12 V 100 AH) I Part Number Reference & Specifications Part Number Power Sonic Part Number Battery Description ______ _______ DIMENSIONS Nominal Voltage Nominal Capacity @20hr. rate A.H. Width Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT-1250 PS-1250 12 5 sealed 5 41 f BAT-1270 PS-1270 12 7 sealed 595 151 256 65 3.7 94 36 98 4.8 218 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 194 100 7.92 359 BAT-12180 PS-12180 12 18 sealed 7.13 181 2.99 76 6.57 167 6.57 167 12.6 5.8 BAT-12260 PS-12260 12 26 sealed 6.56 167 6.97 177 492 125 4.92 125 17 7.71 BAT-12550 PS-12250 12 55 1 sealed 19.04 230 654 138 8.2 208 18.98 1228 36 116.33 BAT-121000 PS-121000 12 1 100 1 sealed 112 305 6.6 168 8.2 1208 18.98 1228 168 30.84 I I I I I DN-6933:CI • 7/13/2011 - Page 1 of 2 I f 4 Charging is NOT necessary unless 100% of capacity is required. Charging before - (41-F) use is necessary to help recover ...,,, full capacity. Charge may failto restore full capacity. 40°C 30°C - 20°C - (104°F) (86°F) (68°F) DO NOT let batteries reach this state. at left: PS-121000 Shelf-Life and Storage 90% 0 80% C..) a 50% Co 40% 0% 6.5 13 6.0 12 a 1 ii 5.0 10 4.5 9 4.0 8 U Characteristic Discharge Curves 1 2 3 5 10 2030 60 2 3 5 10 20 30 minutes hours Discharge Time @ 20°C (68°F) 120% Effect of Temperature on Capacity 100% 80% (0 60% 0 (0 a. um 40% 20% 0% -20° -10° 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) MONOMER 9' Mppop-nd W—.0dwon—Vii N—F-0 .u..u. 100% -- ---- - 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 14.0 V 13.0 V 12.0 V 11.0 V Cs C 10.0 V 9.OV 8.0V All zuiiuu III1UIi!!L!IIlI --I 1.2 2:4 ______ IÔOA II 6 12 24 36481 2 4 6 810 20 40 MINUTES _________ HOURS Discharge Time - at left: PS-121000 Discharge Characteristics I I I NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MMURIN8 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 012— DN-6933:CI • 7/13/2011 DN-6935:D • 14202 :FSP.85i(A) Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® NOTIFIER® by Honeywell General Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851 1(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACP5). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1° (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1' (15.5 cm) diameter. - B501 (A): 4.1 (10.4 cm) diameter. - 13200S(A): 6.875 (17.46 cm) diameter. SP451(A) in B2IOLP(A) Base - B200SR(A): 6.875 (17.46 cm) diameter. - B224RB(A): 6.2° (15.748 cm) diameter. - B224Bl(A): 6.2' (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). ULIULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at system sensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "1-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation DN-69350 • 12/08/2011 - Page 1 of 2 I I I I I I 1 I sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122 BSMI: C1313066760036. CCCF: Certif. #2004081801000017 (FSP-8511) Certif. # 2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed mode! 'FSP-8i'\Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851 A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 1OBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RAlOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851 (A) only; box of 10. -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I I MINMIK a IIIINMUR1111111 All specifications are subject to change without notice. I QUALITY SYSTEMS Made in the U.S. A. 1 For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. Page 2 of 2— DN-6935:1) • 12/08/2011 www.notifier.com I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 272-0028:0206 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com I DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851,SP-851'\ FSP.851R* and FSP-851T photoelectric type smoke detectors. Models FSP-75T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire I situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: I 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible I base and fire alarm control units. Models FSP-751, FSP-7511, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity I between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Electrical Ratings FOR B200S/SR: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 pA maximum. Alarm current: - B200S: 25 mA maximum at high-volume setting; 15 mA maximum at low-volume setting. - B200SR: 35 mA maximum. SLC operating voltage: 15 to 32 VDC. SLC standby current: 300 pA. I I I I ____- Relay Base B224RB(A) B200S(A), B200SR(A) Sound output: measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). - 6200S, high-volume: Greater than 85 dBA minimum. - B200S, low-volume: Greater than 75 dBA minimum. - B200SR: Greater than 85 dBA minimum. FOR B224RB, B2248!: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum © 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A © 125 VAC, 0.9 A © 110 VDC, and 3.0 A © 30 VDC. Product Line Information INTELLIGENT BASES B501: Flangeless mounting base. B501 A: Flangeless mounting base, ULC Listed. B501 BP: Bulk pack of B501 (10). B21OLP: Flanged mounting base. B21OLPA: Flanged mounting base, ULC listed B21OLPBP: Bulk pack of B21OLP (10). DN-60054: E I Intelligent Bases NOTI Fl ER® B501 (A), 13200S(A), B200SR(A), B2241B1(A), B224RB(A), by Honeywell I Mounting Kits, and Accessories Addressable Devices General I Intelligent FlashScan® and CLIP mounting bases and kits pro- vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selec- Cal I tion (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base Flanged Mounting Base and models employ various 12 to 24 AWG wire ranges. B501(A) .B2I01LP(A) Relay, isolator, and sounder bases can be used to meet I local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door clo- sure and elevator recall. Isolator bases allow loops to continue _______ to operate under fault conditions and automatically restore I when the fault is removed. Sounder bases are available in temporal and non-temporal pattern versions depending on whether the signal is to be used for evacuation purposes. i Specifications Diameter: - B501: 4.1 (104 mm). I - B224B1, B224RB, B21OLP: 6.1° (155 mm). - B200S/SR: 6.875' (17.46 cm). Wire gauge: - B224Bl, B224RB: 14 to 24 AWG. I —B21OLP, B501, B200S/SR: 12to24 AWG. Temperature range: —B224B1, B224RB, B200S/SR: 32°F to 120°F (0°C to 49°C). I —B21OLP, 6501: -4°F to 150°F(-20°Cto66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). B200S: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and cus- tom tone. B200SA: Same as B200S with ULC-listing. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: Same as B200SR with ULC-listing. DN-60054:E • 7/22/2011 -Page 1 of 2 Junction Box Selection Guide Base Models Single Gang 3.5 Oct. 4.0" Oct. 4.0" Sq. 4.0 Sq. with 3.0 mud ring 50 mm 60 mm 70 mm 75 mm B200S, B200SR Yes Yes Yes Yes Yes No No No No B501 ., No Yes No No Yes Yes Yes Yes No B21OLP\ Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. I I I I I I I 1 I I I I I I I 1 I I I B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. B224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F110: Retrofit flange for converting high-profile bases to low- profile. F110BP: Bulk pack of F110 (10). F210: Accessory flange ring for B21OLP(A) base (new design). 6-inch diameter. F21OBP: Bulk pack of F210 (10). RA100Z: Remote LED annunciator. RA100ZA: Remote LED annunciator, ULC Listed. M02-04-00: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool for current heads (T55-127-010 included). XR2: Detector Remove Tool for use with low profile detector heads, and FSL-751. XP-4: Extension pole for XR2/B (5 to 15 ft/1.524 to 4.572 m). T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with photo and ion detectors). WCK-200B: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S911 ULC Listed: S911 FM Approved MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E CSFM: 7300-1653:0126, 7135-1653:0213, 7300-0028:0173, 7300-1653:0109 FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. 93a=1=1 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60054:E • 7/22/2011 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 73O0-1653:0109 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of I LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.kireyev@honeywell.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, 1340413, B404BT, 1340613, B501, B50IB, 14506587-002, B501BH, B501BHT, B4OIBH, B110LP, B110RLP, B11ORLP75O, B112LP, B114LP, B114LPBT, B116LP andB21OLP detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I I I DN-6724:133 (FCM.1(A) & FRM-1 (A) NOTIFIERSiii0 Control and Relay Modules by Honeywell I Intelligent /AddressableDevices General 'FCM-l(A) Control Module: The FCM-1(A) Addressable Con- irol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 (A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). T1 I LI PWR(1 110 EI PVVRi•I FCM-1(A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 I I I I I I I I I I I I I I I Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and 111): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM-1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (L/R=5ms) 1 A Inductive 30 VDC Coded (L/R=2ms) .3A Inductive 125 VAC Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. CM-11(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mcunt Backbox. CB500: Control Module Barrie- - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructiors, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. I Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x I 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. . We cannot cover all specific applications or anticipate all requirements. IllNI I MdI11RIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 464-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 DN-6720:C • H-220 FMM-1 (A), FMMi 01(A), FZM-1 (A) &KFDM.i(A) Monitor Modules with FlashScan® NOTIFIER® by Honeywell General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FzM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-1 01(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 (A) can be used to replace MMX-1 (A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125' (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 I I I I I I I I FMM-101(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 14 15 0 1 ADDRESS 0 1 LOOP 10 El 8 76 8 76 TENS ONES The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-1 01(A) can be used to replace MMX-1 01(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. FZM-1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install [LA across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4° (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125° (5.398 cm) deep box. L I I Cr oliliw II-j 1H 0 I, ..-jll -jII 110 I L H ii F Page 2 of 4— DN-6720:C • 10/06/2010 FDM1(A) Dual Monitor Module The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM- 1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) lOG circuits are NOT supported in any application. - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-1/-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM-1) - 02/60007 (NFS-640: FDM-1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information FDM-1(A) SPECIFICATIONS NOTE: "A" suffix indicates ULC-listed model. Normal operating voltage range: 15 to 32 VDC. FMM-1(A): Monitor module. Maximum current draw: 6.4 mA (LED on). FMM-1 01 (A): Monitor module, miniature. Average operating current: 750 pA (LED flashing). FZM-1(A): Monitor module, two-wire detectors. Maximum IDC wiring resistance: 1,500 ohms. 'IFDM-l(A): Monitor module, dual, two independent Class B cir- Maximum IDC Voltage: 11 Volts. 'cuits. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING I The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address 26", then it will automatically assign itself to addresses "26" and '27". I NOTE: "Ones" addresses on the FDM- 1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. I A CAUTION: Avoid duplicating addresses on the system. Installation FMM-1 (A), FZM-1 (A), and FDM-1 (A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51253. DN-6720:C • 10/06/2010 - Page 3 of 4 I I ii I I I I FlashScan® and NOTIFIER® are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. @2010 by Honeywell International Inc. All rights reserved. Unauthorized use I of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I ____________________ We cannot cover all specific applications or anticipate all requirements. 9111INBINS a 11111NOWME All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. I www.notifier.com Page 4 of 4 - DN-6720:C • 10/06/2010 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 004028:0219 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 I Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101Fi\ FTM-1 monitor modules; FCM-1, FRM-1 control modules, and FDRM-1 with 2 input/2 output I relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm I control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. I NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. I This is done in order to detect ground faults on the initiating circuit. I Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. f SYSTEM SENSOR® Indoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. I Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG APPROVED oi LISTED S5512 FM approved except 7225-16530504 S4011 for ALERT models 7705-1653 0503 3057383 I I r I L-Series Specifications General I L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output I and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. I Strobe The strobe shall be a System Sensor [-Series Model listed to U[ 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and I associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to U[ 1971 and U[ 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C 10 to 93% non-condensinc Strobe Flash Rate 1 flash oer second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 Cd. I I I I I I UL Current Draw Data 'UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR I 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A I 134 164 115 N/A 158 191 150 N/A 189 228 I 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd I 30cd 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 I 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 I 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 107 I 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 I Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 I 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data and Horn Strobe Output (dBA) I Horn 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal I High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal I High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 I I I I L-Series Dimensions 2.47 1.37 Ø6.8 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box I I I I I I I 2.50 L-Series Ordering Information Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red K PC2WL1 2-Wire, Horn Strobe, White I I I I I I I I I Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Product specificafons subject In Change without notice. Vet systemsensorcom ©2017 System Sensor. $ Phone 800-SENSOR2 • Fax AV008 630-377-6495 for current product information, -clad r'g he latest nero on of iris data sheet. 6SOS • 03/17 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. '7135-1653:050 Page 1 of 2 CATEGORY: 7135— AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL andL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I Li I I I I Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. I I I I I 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division