Loading...
HomeMy WebLinkAbout2544 CAMPBELL PL; 150; FPC2020-0096; PermitPERMIT REPORT (rcity of Carlsbad Print Date: 09/10/2020 Permit No: FPC2020-0096 Job Address: 2544 CAMPBELL PL, # 150, CARLSBAD, CA 92009-1768 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132611800 Track #: Applied: 05/28/2020 Valuation: $631,884.86 Lot #: Issued: 06/09/2020 Occupancy Group: Project #: Finaled Close Out: 07/28/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ADVANCED DIABETES SUPPLY -SPRINKLER TI (27 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760),295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A ITAwN PRE PROTECTION Fire Protection Contractor - License #98980 / FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 19684 ADVANCED DIABETES SUPPLY 2544 Campbell PL. #150 Carlsbad, CA 92009 ZURN Model 35OADA EXISTING ________ Double Check Detector Assembly Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Horizontal & Vertical) ASSE® Listed 1048 AWWA Compliant C510 (with gates only), and C550 CSA® Certified B64.5 UL® Classified C-UL® Classified FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA221-04M-2 (2 1/2' -8") Meets the requirements of NSF/ANSI 61* (025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4' Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved electrostatic epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Features Sizes: 2 1/2*, 3"° , 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged bolt pattern) ASME 616.42 Class 150 *2 1/2" & 3" sizes use 4" body & reducer couplings Dimensions & Weights (do not include pkg.) MODEL WEIGHT 350ADA SIZE in. I mm LESS SHUTOFF VALVES lbs. I kg OSY GATE VALVES FLANGED lbs. I kg OSY GATE VALVES GROOVED lbs. kg BUTTERFLY VALVES FLANGED lbs. I kg BUTTERFLY VALVES GROOVED lbs. I kg 21/2 65 105 48 192 87 184 83 157 71 147 67 3 80 104 47 210 95 200 91 162 73 148 67 4 100 91 41 230 104 204 93 147 66 139 63 6 150 141 64 362 164 332 151 246 111 215 98 8 200 302 137 762 346 738 335 491 223 445 - 202 10 250 355 161 1024 464 902 409 628 285 570 259 LEAD FREE I 1,1SRAMI 61 (with OS&Y gates) (with BG valves) Options (Suffixes can be combined) D - with flanged end OS & Y gate valves (standard) O L - less shut-off valves (grooved body connections) 0 LM - less water meter 0 - with gallon meter (standard) 0 CFM - with cu ft meter CMM - with cu meter meter G - with grooved end connections 0 FG - with flanged inlet connection and grooved outlet connection 0 P1 - with Post Indicator Gate Valves 0 BG - with grooved end butterfly valves with integral supervisory switches 0 BF - with flanged end butterfly valves with integral supervisory switches Accessories O Repair kit (rubber only) 0 Thermal expansion tank (Model XT) D OS & Y Gate valve tamper switch (OSY-40) 00 MODEL 350ADA with OS&Y option MODEL DIMENSION (approximate) 350ADA SIZE in mm A in I mm A WITH BUTTERFLY VALVES in I mm B LE GATE SS VALVES in mm C in mm D in I mm 0 E S&Y OPEN in I mm F OS&Y CLOSED in mm E WITH BUTTERFLY VALVES in mm F in mm G in mm 21/2 65 351/8 892 321/8 816 201/8 511 41/2 114 229 173/4 451 153/8 391 17 432 6 152 71/4 184 3 80 361/8 918 33 838 201/8 511 41/2 114 229 201/4 514 17 432 17 432 6 152 71/4 184 4 100 381/4 972 331/4 845 197/8 505 41/2 114 229 221/2 572 181/4 464 17 432 6 152 8 203 6 150 471/4 1200 401/4 1022 257/8 657 51/2 140 254_V305 267 301/2 775 241/4 616 17 1/2 445 7 178 10 254 8 200 62 1575 55 1397 381/2 978 10 37 940 281/2 724 1615/16 430 81/2 216 11 279 10 250 645/8 1641 59 1499 381/2 978 10 254 305 455/8 1159 343/4 883 1615/16 430 81/2 216 12 305 Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. Zum Industries, LLC I Wilkins 1747 Commerce Way, Paso Rabies, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Rev. L Date: 3/20 Document No. BF-350ADA Patent No. 5, 913, 331 Product No. Model 350ADA Page l of 2 Flow Characteristics 0.0 15 U) 0. 0 10 U) 9 UI U) U) UI 'Rated Flow (established by approval agencies) MODEL 350ADA 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (L's) 12.6 25.2 37.9 50.5 104 0 69 LIJ 35 (1) Ui 00 0 200 400 600 800 FLOW RATES (GPM) MODEL 350ADA 6",8" & 10" (STANDARD & METRIC) FLOW RATES (L's) 0.0 63.1 126.2 189.3 252.4 0. cc 5 Lu 0 U) IL 0 1000 2000 3000 FLOW RATES (GPM) "15 U) ____________ 10 II - 1L H H II U II 11 H II 104'@ 69 LU 35 00 4000 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains With sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. MODEL 350ADABG (Vertical Installation) Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/2 75 112 149 224 3" 115 173 230 346 4 198 298 397 595 6" 450 675 900 1351 8' 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 PROTECTIVE MODEL 350ADA (Outdoor Installation) Specifications The Double Check Detector Backf low Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backf low Prevention Assembly shall be a ZURN WILKINS Model 350ADA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 934.46 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 ;-.. 4_.. Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.0459501 Technical Services: 877-3845464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK602 is a small therrnosensltive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements, This sprinkler has both standard response and quick response listings. The glass bulb operating element and special deflector char- acteristics meet the challenges of quick response extended coverage standards. The special Polyester coating can be used in decorative applications where colors are desired. LISTINGS AND APPROVALS cULus Listed; Category VNIV FM Approved: Class 2020 Refer to Approval! Chart I and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA For Light Hazard Occupancies Only NOTL As of My 2G1 I a# kW hive bqaft r*mo,.4 from thw wmach bom WARMIIO. Cnrind Spectficatons: I____________________________ Available since 2013. Minimum Operating Pressure; Refer to the Approval Charts, Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread sizes: 3/4" (20 mm) NPT Nominal K-Factors: 8.0 U.S. (115.2 metricl-) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sorinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order ECIQREC Pendent Sprinkler VK602 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester M-/W, and Black Polyester M-/B Temperature Suffix: 135°F (57 °C) = A, 155°F (68 °C) = 8. 175 F (79 °C) = D For example, sprinkler VK602 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18262BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches; Standard Wrench: Part No. 21475M/B (available since 2017) Wrench for recessed pendent sprinklers; Part No. 13577W/B** (available since 2006) **A W ratchet is required (not available from Viking). Form No. F_102412 19.02,21 Rev 19.1 Replaces Form No, F.,102412 Rev 18,2,P65 (Removed F-I Escutcheon.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877.384.5484 Fax: 269.818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupInc.com. Sprinkler Cabinets: Six-head capacity; Part No, 01724A (available since 1971) Twelve-head capacity; Part No, 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands,causing the glass to shatter, releasing the pip cap and sealing springassembly. Water flowing through the sprinkler orifice strikes the sprinklerdeflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking EC/QREC Pendent Sprinkler VK602 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient ' Color lb 8 U Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 F (57 °C) 100 F (38 C) Orange Ordinary 155F(68°C) 100 °F(38C) Red Intermediate 175 °F (79 °C) 150 F (65 °C) r Yellow Sprinkler Finishes: Brass, Chrome, White Polyester3, and Black Polyester' Footnotes The sprinkler temperature rating is stamped an the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards, For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. Wrench Flat Protective Sprinkler Clip Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F10,2412 19.02.21 Rev 19.1 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 2694454501 Technical Services: 877.384-5464 Fax: 269.818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vIkinggroupinc.com. Approval Chart I (UL) KEY Standard/Quick Response Extended Coverage Pendent Sprinkler For Light Hazard Occupancies Only. Maximum 175 PSI (12 Bar) WWP Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Areas of Coverage4 n mum Mi I Warupplyequ remen s R Listings and Approvals3 Part No,' (Refer also to Design Criteria.) Inches F mm U.S. j metric5 (Length x Width) Standard Response ApplIcatlons cUL,us5 18262 VK602 314 20 8.0 115.2 20'x 20'(6.1 m 6,1 m) 40 9prn @ 25,0 psi (151.4 tJmin @ 1.72 Bar) AIZ Quick Response Applications 18262 VK602 3/4 20 8.0 115.2 16'x 16'(4,9 rn x 4.9 rn) 26 gpm @ 10.6 psi (98.4 L/min @0.73 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 18'x 18' (5.5 m 5.5 rn) 33 gpm @ 17.0 psi (124.9 LJmin @ 1.17 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 20'x 20'(6.1 m 6.1 m) 40 gpm @ 25.0 psi (151A L/min @ 1,72 Bark BIY Standard Response Applications cULus5 07077 [VK602 F7/4 20 80 1152 20 x 20 (6 1 mx 6 1 rn) [40 gpm @ 250 psi (151.4 L/mrn @ 1.72 Bar) AIZ Quick Response Applications 07077 VK602 3/4 20 8.0 115.2 16'x 16'(4.9 m 4.9 m) 26 gpm © 10.6 psi (98.4 Llmin @0.73 Bar) CIZ 07077 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) C1Z 07077 VK602 3/4 20 8.0 115.2 20' x 20' (6.1 m 6.1 rn) 40 gpm @25.0 psi (151.4 Umin @ 1.72 Bar) BIY Sprinkler Temperature Ratings Approved Finishes Approved Escutcheons A- 155°F (68 °C) and 175°F (79 °C) I - Brass, Chrome, White V - Standard surface-mounted escutcheons B - 135 °F (57 °C) Polyester, and Black Z - Standard surface-mounted escutcheons or recessed with the C - 135°F (57 °C), 155°F (68'C), and 175°F (79 'C) Polyester Micrornatic Model E-1 or E-2 Recessed Escutcheon Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown Is when pressure is measured in Bar. When pressure Is measured In kPa, divide the metric. K-factor shown by 10,0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the Minimum Water Supply Requirement" for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per sprinkler. Listed by Underwriter's Laboratories,. Inc. for use in the U.S. and Canada for Light Hazard occupancies with smooth, flat, horizontal ceilings only. cULus Listings are limited to Light Hazard occupancies, where allowed by the installation standards being applied. Form i',io. F_102412 19,02,21 Rev 19.1 (Note the or-iri iu uuri or the shield in the wrench,) Sprinkler Wrench 3577V/B* must be used For installing recessed sprinkler VK600 and VK602 *A 1/2" ratchet is quired (not available from Viking), en 2 CareFully press the wrench upward and ensure engagement with the sprinkler wrench Flats Step 1: Corefl wrench sides the sprinklel and protec Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877.384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESIGN CRITERIA - UL (Also refer 'o Approval Chart 1) cULus Listing Reculrements: Standard/Quick Response Extended Coverage Pendent Sprinkler SIN VK602 is cOLus Listed as indicated in the Approval Chart for installation in ac. cordance with the latest edition of NFPA 13 for extended coverage pendant spray sprinklers: Limited to Light Hazard occupancies, where allowed by the installation standards being applied, with smooth, flat, horizontal ceilings only. Minimum spacing allowed is 8 ft. (2,4 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 In. (102 mm), Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers, The distance shall be measured per- pendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendant spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 2: Wrench 13577W1B for Recessed Pendant Sprinkler VK602 Form No. F10,2412 19.02.21 Rev 19.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone; 269-9459501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcsvIkingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Approval Chart 2 (FM) KEY Quick Response Extended Coverage Pendent Sprinkler -- Base SIN NPT Thread e_ Maximum 175 PSI (12 Bar) WWP Sprinkler Nominal K-Factor Maximum Areas of Coverage4 Minimum Water Supply Requirements' FM Approvals (Refer also to Design Part Number' Criteria below.) Inches I mm U.S. metric3 (Length x Width) 18262 VK602 3/4 20 8.0 1152 16 x 16(4,9 rn x 4.9 rn) 26 gpm @ 10,6 psi (98,4 L/miri @ 0,73 Bar) AIZ 18262 VK602 3/4 20 8,0 115.2 18' x 18' (5,5 mx 5.5 rn) 33 gpm © 17,0 psi (124.9 L/min @ 1.17 Bar) AIZ 18262 VK602 3/4 20 8.0 1:15.2 20'x 20'(6,1 mx6,i rn) 409pm@25,o psi (151.4L/min@ 1,72 Bar) AIZ Sprinkler Temperature Ratings Approved Finishes Approved Escutcheons A - 135 F (57 C), 155 F (68 C), and I Brass, Chrome, t0 Poly-ester: Z - Standard surface-mounted escutcheons or the Viking Mlcrofast and ct er Model F-I Adjustable Escutcheon, or recessed with the Micro matrc Model E-1 or E-2 Recessed Escutcheon Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured In Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement' for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per spr'rkler. DESIGN CRITERIA- FM (Aso refer to Approval Chart 2 above) FM Aoeroval Rectuirements: Quick Response Extended Coverage Pendent Sprinkler VK602 is FM Approved as quick response Non-Storage extended coverage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus andlor NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, Installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA. LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F102412 19.02.21 Rev 19,1 1-1/8" (28,6 mm) Minimum 1-1/8" (28.6 mm) Minimum 1-3/4" (45 mm) Maximum 2" (51 mm) Maximum Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945.9501 Technical Services: 877.384.5464 Fax: 269.818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Ceiling Opening Size: 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum I, 2-3/8' (60 mm) I-_ (35 mm) Pendent Sprinkler 18262 (VK602) 1-3/4' (45 mm) Standard 1/8' (3.1 mm) surface-mounted escutcheon Figure 3: SprInkler VK602 Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (58,7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" (54 mm) (54 mm) Installed with a Micr'omatic Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Sprinkler VK602 Dimensions with the Model E-1 and E.2 Recessed Escutcheons Form No. F_102412 19.02.21 Rev 19.1 Replaces Form No, FJ024i2 Rev 18.2.P65 (Removed F-I Escutcheon.) = i SM. I E-0 l.M A!EJ L LIsjrIEE Sl ~,LEIj IJIE 1~y C®IJS LISTED NFFA' SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE OJ). ID, WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR#* WEIGHT/FT WEIGHT SIZE 1 1,315 1.097 15.27 1.41 lbs/ft 1.820 91 1-114 1.660 1.442 , 1.81 lbs/ft 2.518 61 1-1/2 1.900 1,682 7.76 2.09 1bs/ft 3.053 61 2 2.375 2,157 6.27 2,64 4.223 2-1/2 2.875 2.635 4.92 333 lbs/ft 5.893 30 3 1.500 3.260 354 4341bs/ft 7.951 19 4 4.500 4160 2.50 5.62 1bs/ft 11,796 19 NOMINAL PIPE O.D.I.D WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1,900 1.610 1.00 2,72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2.112* 2.875 2.468 1.00 5.80 1bs/ft 7.875 30 3* 3.500 3.068 100 758lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 '04V veallabk irk Cm GndAz We W ramt UI. flitiy 1itin PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a teak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease. and rust must be removed prior to Installation. Failure to take these important steps may result in improper coupling assembIc causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www.buItmoosetube.com Or From Canada Call (800) 882-4666 satesObullmoosetube.torn 1819CiatksonRoad thsttfk4d, MO GjakI, MO KcetWA Casa Grui&AZ DalITX Mst*r ON Bull Moose Tube's!* Schedule 10 and Schedule 40 are FM Approved and Lii Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose lube° made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASIM A123 standards. All products are stencilled to meet FM & (IL specifications. a J-- .111111 g W1 MT 6 1I1TAWAE I Dull Moose Tube's°Eddythread40° ADVANTAGES 0 BULL MOOSE TUBE° EDOVTHREAD 400 U is a lightweight replacement for • Has a corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet preaction, and deluge type sprinkler systems. 'Can be hot dipped galvanized to meet FM'S requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. NOMINAL PIPE MOL ID. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR' LBJFT WEIGHT SIZE t 1.295 1,083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 100 :. 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2347 3.468 44 2 2.375 2.123 100 3.309 4.842 30 eouD Rak per latelt LL Dktoq L51ne r c®us LISTED <19> 11 .4 ONFSA NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to Installation. Failure to take these important steps may result In improper coupling assembly. causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 32S4467 wwthuItnioosetube.corn Or From Canada Call, (800) 882-4666 salesbuIImoosetube.com U 1819 CLvksdn Road *strlIkL MO Gtht MO KmWA Cm &aidM btiX 63017 5 E!4L1jj B EIEB 1! Bull Moose Tube's Eddylite* is a lightwall threadable pipe manufactured in NPS I through 2'. Edchjlite° is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness,, or standard outside diameter. Eddylite is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. 6 ADVANTAGES OF BULL MOOSE TUBE° EDDVLITE° Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASIM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service. life. Better hydraulics than Schedule 40. 'Wall thickness and weight close to Schedule 30: compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CPR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O0. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED SIZE I 1.315 1.137 0.13 7,47 1.260 1.700 91 1-114 1.660 1.482 0.08 4.79 1.617 2.364 61 1-112 11900 1.712 0,12 4.53 1.967 2.965 61 2 2.375 2.177 016 431 2.617 4,230 37 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leaktight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale dirt chips, greases and rust must be removed prior to Installation. Failure to take these Important steps may result In Improper coupling assembly. causing leakage. Also, check the manufacturers instructions for the specific fitting used. A ForAdditional Information Contact (800) 3254467 www.bullmoosetuho.com Or From Canada Call (800) 882-4666 salesbuIlmoosetub torn U 1819 CIakon Road chfkld,M0 GotaK KntWA WKWX Mam0H 63017 Bull Moose Tube's* Eddy FIOW is a specialty engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibiIity, This product is FM approved, as well as UI. Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's0 larger ID provides an opportunity for downsizing and further cost savings. ADVANTAGES OF BULL MOOSE TUBE° EDDY FLOW° Certified to ASIM All 35 and A795 Type F, Grade A. FM approved for roil grooving and welding for use in wet systems. UL Listed (for U.S, and Canada) for joining by welding or by listed rubber gasketed fittings for use In wet, dry,preaction and deluge type sprinkler systems. Lightweight saves shipping costs and offers easier handling. Can he used with roll grooved couplings or welded outlets for pressures up to 300 psi Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD 110 MIC preventative coating. -I NPS OD. EDDY FLOW EDDY FLOWO WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR PER Ft wrl ShE 1414 1.660 1.530 1.98 1,222 2.019 61 1-1/2 1.900 1.728 344 1844 2.860 61 2 2.375 2.203 2.78 2,330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3300 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 - 4.968 11.290 19 Rihkwoo Uid &ttUI OlrttUtliq PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation In order to provide a teak tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale. dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ForAdditional Information Contact (800) 3254467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saiesebuhlmoosetubecorn U 1a19CLt.enROM thurLMO GaIMO Keitft Casa ndA2 DaILKtX MAU4 ON ULTRA E It!Y® THE SUPERIR SPRINKLER PIPE Bun Moose Tube's° Ultra Eddy0 is ADVANTAGES OF BULL MOOSE TUBE° ULTRA EDDY° a versatile product that can he • Certified to ASTM Al 35 and A95 Type E, Grade A. roll grooved welded and used with • EM approved for roll grooving and welding for use in wet systems Pressfit* Products. • UL Fisted (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dr preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional Can be used with all Schedule 5 approved roll grooved, welding and Pre sfit4 Products for pressures up to 175 psi. Designed to generic Schedule S tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today. Ultra Eddy* offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS 0.0, ULTRA ULTRA EDDY WEIGHT WATER BUNDLE (IN) (IN) EDDY* (ID) CRR PER Ft FILLED Wt. SIZE 1 1.315 1.201 2.17 .68 1359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 ., L 0ryutiri c®us LISTED (a 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. AM loose paint scale, dirt chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembl causing leakage. Also, check the manufacturer's instructions for the specific fitting used, ForAdditional Information contact (800) 325'4467 www.bultmoosetube.com Or From Canada Call (800) 882-4666 salesbulImoosetube corn J lB 9CIkMm Road 0wterfidd,M0 G"A MC) KotWA Casa GtdoAz DdIa,TX MAWA ON 63017 3EJT 1EJJZ7 JPr4 - NPS(IN) 1 1-114 1-112 2 2-112 3 4 OLD. (in) 1.315 1.660 1.900 2.375 LM (in) 1.201 1.546 1.186 2.261 ULTRA EDDYQ EmptyWeight (I&ft) 01868 1.107 1,274 1,604 Waw-Fdled Weight Ch"' 1.359 1.920 2.360 3,344 CJ.R. 2.17 1.40 1.11 1,00 CQ 1.660 1.00 2.37S 2,87S 3.500 4.500 IIXn) 1530 f 1,728 2203 2705 7 3,334 4.310 EmptyWtght(tb1it 1.222 1344 2,330 2809 3,361 4,968 EDDY FLOW V4zer-MledWeight 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 OLD, (in) 1,315 11660 1.900 2.375 2.875 3,500 4.500 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Emptyinft) 1.410 1.810 2.090 2.640 .530 4.340 5.620 10 Watd%htOMU 1.820 2.518 3.053 4.223 5,893 7,957 11.796 C.R.R. 15.27 9.91 7176 6.27 4.92 3.54 2.50 0.D.fir 1.315 1.660 1.900 2.375 1.137 1.482 1.712 2.177 [DDYLITE° Empty Weight'ft 1.260 1.617 1.967 2.617 tter.fiIIedWetghtlMt) 1.700 2,364 2965 4.230 cAR. 013 008 012 016 ark Qr~ 1.295 1.650 1.900 2.375 LD,1.083 1.413 1.645 2.123 EDDYTHREAD ErVt(/ft) 1.461 2,070 2.547 3.308 400 ter-fi1iedWJi(1t 1.860 2.754 3.468 4.842 CAR, 1.00 1.00 1.00 1.00 an Oro 1.315 1.660 1.900 2,375 2.875 3,500 ' 4,500 1.00n) 1.049 t! 1.380 ' 1.610 2.067 2.469 3.068 4.026 SCHEDULE Empty Weight 1.680 2.270 2.720 ' 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 c.R,R. 1.00 1,00 1.00 1.00 1.00 1.00 1.00 A For Additional Information Contact (800) 325-4467 www buitmoosetube corn 11, 10 Or From Canada Call (800) 882-4666 satesbullmoosetube corn 119Clwksn Road U Chtrft€1d,M0 GsakIM0 Knt,WA CaGand,AZ M114TX Ma 0H 63017 13 c®us LISTED 10 I? EE JUELX E1T I J 21 24 1 25 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY0 0.868 91 1,659 1,896 1.975 SCHEDULE 10 1.410 91 2,695 3,079 3,208 1 EDDYUTE0 1.260 91 2,408 2,752 2.867 E0DYTHREAD40 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2.470 2,822 2,940 U1TRAE0DY " 1.107 61 1,418 1 1.621 1.688 EDDY FLOW* " 1.222 61 1.565 :.1,789 '. SCHEDULE 10 1.810 61 2.319 2.650 2,760 11/4 EDDYLITE* 1.617 61 2,071 2,367 2,466 EDDYTHREAD40 2.070 51 2,217 2,534 2,639 SCHEDULE 40 2.270 51 2,431 2,778 2.894 ULTRA EDDY 1.274 61 1,632 11865 1,943 EDDY FLOW 1.844 61 2,362 2,700 4812 SCHEDULE 10 2.090 61 2,677 3,060 3,187 1-1/2 , EDDYUTE° 1.967 fil 4520 2,880 3.000 EDDYTHREAD 40-v 2,547 44 2.353 2.690 2,802 SCHEDULE 40 2.720 44 2,513 2,872 2.992 ULTRA EDDYa 1.604 37 1,246 ' 1,424 1,484 EDDY FLOW 2.330 37 1,810 2,069 2 155 SCHEDULE 10 2,640 37 2,051 2,344 2,442 2 EDDYLI1'E , 2.617 37 :, 2,033 2,324 2,421 EDDYTHREAD 409 3.308 30 2,084 2,382 " 2,481 SCHEDULE 40 3.660 S 30 5 2.306 2,635 2,745 EDDY FLOW* 2.809 1,770 2.022 2,107 2-1/2 SCHEDULE 10 3,530 30 2,224 2,542 2,648 SCHEDULE 40* 5.800 3.654 4,176 4,350 EDDY FLOW 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4340 19 1,732 1,979 2,062 SCHEDUL.E40* 7.580 3,024 3,456 3,601 EDDY FLOW-' 4.968 1,982 2.265 2,360 4 SCHEDULE 10 5.620 19 2,242 2,563 2.670 SCHEDULE 40 10.800 4,309 4.925 5,130 6 SCHEDULE 10 9.289 10 1,951 2,229 2,322 8 SCHEDULE 10 16.940 7 2,490 2.846 2,965 0nAA k C&a GtWide, AL T!L1E T4!JBE JJ3IIJ EE E S9l LJ3iJ gE 5- EL QZ8i!iS] Butt Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or CompressiontGrooved Couplings Max Zone of rnlluence Load (Fw lbs. Max. Transverse and 4-way Brace Spacing (ft.)`— According to HLF for the 2006 & 2009 IBC (ASCE ) & Qfor NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 1 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2,50 2.75 3.00 1 114 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1112 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 291 244 209 115 40 40 40 38 34 31 28 21 25 24 23 22 21Q 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 1 809 6481 531 4651 381 40 40 40 40 1 37 34 31 29 28 26 25 24 4 1 1544 1235 1 1012 867 726 40 40 40 40 1 40 37 34 32 30 29 28 26 Butt Moose Tube EDOYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Loud (Ppiel lbs. Max. Transverse and 4-way Brace Spacing (ft.) '-• According to Pipe Transverse Brace Spacing* HLF for the 2006 & 2009 IBC ( ASCE0 ) & C-0 for NFPA-13 shown In BOLD TYPE size 20 ft. 1 25f1 30f1 35 ft. 40 ft. 0.25 0.50 0,75 1.00 1.25 1.50 1 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1114 218 115 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 112 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 ........... 1819 Clarkson Road Chesterfield, MO 63017 PHONE: 800 325-4467 FAX: (636) 537-2645 www.butlmoosetube.com sales@bullmoosetube.com c®us LISTED ARM (] /i\ONFSA FLFPA' '' Q For Additional Information Contact (800) 325-4467 wwwbuUmoosetube.tom Or From Canada Call: 800 882-4666 saIesbuIImoosetube.tom t819dikonRod th1IIdM0 Gerald, M0 Knt,WA CM GraWW Dalta%TX mask" o" -- eftlymy4y 63017, 11 111y,"Pechanica1T' STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts, Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene ()-iDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap Il Mechanical-T unit. See page 8 for further information, STYLES 920 AND 920N STYLE 920 cgoss PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade '°E" EPOM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade °r nitrite Nitrile (Orange color code). Temperature range —20°F to +1807/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended., Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-I83. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted. By Spec Sect Para___________ Location Date________ Approved www.victautic.com VcTAuLIC 15 A REGISTERED TRADEMARK OF VCTAuLIC COMPANY. 02017 vCTAuLIC COMPANY. ALL RIGHTS RESERVED 4tauPicr FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with NDPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings Cannot be mated to one another to achieve cross connections. eD 'à 53 p Pd ' 2 ½ (a) x 920N 500 150 200 253 1.61 535 215 3.1 50 15 3450 38,1 51 64 - 41 136 70 1,5 - Y. (a) - 500 1.50 1,97 2.53 - 1.61 5.35 2,75 3.1 - 20 920N - 3450 38] 50 64 41 136 70 1.5 1 Ia) a 920½ 500 1.50 1.85 253 1.61 5.35 2,75 3.0 25 3450 381 47 64 41 136 70 1.4 - 9204 503 175 205 275 300 16 535 - 300 - 35 32 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2 1a;taI 90N 500 1,75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 , 3450 44.5 52 70 79 41 136 83 1.7 1.5 2½ x 1/2 (a) 92014 500 1.50 2.21 2,74 1.82 5.64 2,75 3.0 65 15 , 3450 38.1 56 70 - 46 143 70 1.4 - 4 (a) §a 920N 500 1.50 2.18 2.74 1,82 5.64 2,75 3.0 20 3450 381 55 70 - 46 143 70 1.4 - 1 920N 500 1.50 2.06 274 1,82 5.64 2.75 2.9 25 3450 38.1 52 70 46 143 70 1.4 - 1771111 920N 500 1.75 20 300 375 182 629 303 35 32 32 3453 44.5 58 76 85 46 150 76 1.7 1,5 1½ t 92015 500 2,00 2,28 3,00 3.25 1.82 6.26 3.25 3.6 3.3 40 1 3450 50.8 58 76 83 46 159 83 1.7 1,6 761 x ½ (à) 90N 300 1.50 2,22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 57 164 81 1.8 / (a; 920½ 300 150 219 275 - 2.25 56 3.18 39 20 2065 38] 56 70 57 164 81 1.8 - 1(a) 920N 300 1,50 2.07 2.71 ' -- 2.25 6.46 3.18 33 - 25 2055 38] 53 70 57 164 81 1.7 ¼ 1 (½ a 920½ 500 1.75 2.30 3.00 331 1.92 6,29 3.00 ' 3.5 12 32 - 3450 44.5 58 76 84 49 150 76 1.6 1.5 1112 (à) 920)4 500 2.00 2.28 3.00 3.31 1.92 5.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1,6 1.5 3 , ½ ½) a 920½ 500 1.50 2.52 3.05 2.28 6.15 2,75 3.4 80 15 3450 38] 54 78 58 156 70 1.6 - 500 1.50 2,493.05 - 2.28 6,15 2.75 3.4 - 20 ,' 3450 381 , 63 78 58 156 70 1.6 1(a) 920¼ 500 1.50 2.38 3,06 2.28 6,15 2,75 3.3 25 ' 3450 38.1 61 78 58 156 70 1.6 - 9204 500 1.75 2,55 325 3.56 2.28 6.15 3.00 3.8 3.7 32 (b)3450 44,5 65 83 90 58 156 76 1.8 1.8 1/2 920½ 00 230 278 50 356 228 65 325 41 38 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) I 920½ 500 2.50 2.75 3.50 156 2.28 6.75 3.88 4,9 4.6 50 5450 63.5 70 89 90 58 172 99 2.3 2.1 3½ 2 500 2.50 3.00 175244 6.72 3,88-r 3.8 90 920¼ 50 ' 3450 63.5 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON P. 3 " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. It Female threaded outlets are available to NFl and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed, Specify "BSPT' clearly on order (b)For 76.1 mm threaded outlet, specify 2½ BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. wwwv)ctauIic.ccm \j(ctauhcr VICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1L62.2 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-Ti' Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS rio 73 J ra as aa 47aa Y Z TABLE CONTINUED FROM PAGE 2 4 , ½ (a) a 920~ 500 150 3.33 3.56 2.69 7.01 2.75 3.7 V IR 100 15 3450 38.1 77 90 68 (78 70 1.8 - 920N 500 1,50 3.00 3.56 2.69 7.01 275 3.7 -- "T 20 - 3450 38.1 - 76 - 90 -- - 68 178 70 1.8 - W 1(3) 90N 500 1.50 2.88 3.56 2.69 7.01 2,75 3.6 - 25 3450 38.1 73 90 - 68 178 70 1,8 GROOVED OUTLET 1 /4 (a) '' 920~ 500 175 308 3.78 4 oi 69 70 3.00 0 ' a 6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1½(a)ta 500 2.00 3.28 4.00 -. 4.00 2.59 7,01 3.25 4.2 3.9 40(b) 3450 502 83 102 102 68 178 83 2.0 1.9 2(7 7 920~ 500 2,50 3.25 4.00 4.00 2.89 7.01 3.88 5.0 48 ' 50 3459 63.5 83 102 102 68 178 99 2,3 2.1 V 25)) 920 500 275 283 490 400 269 734 463 - 8 50 I " 65 3450 , 69.9 73 102 102 68 186 118 2.6 2,3 76' 920 500 2,75 2.88 4.00 2697.34 463 64 w .. mm ....3450 69.9 73 -, 102 68 186 118 2.9 3(e) t 500 3.50 3.31 4.50 4,12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 195 130 3.8 2.9 FEMALE THREADED OUTLET 1 a 920~ 500 1,75 3,08 3.78 2,63 7,64 3.05 5.0 108.0 X 32 3450 44.5 78 95 67 194 78 2.3 - 1 'I, (a)a 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 Provides a direct branch connection at 40 920N ,_ 3450 50,8 83 102 - 67 194 83 2.3 - any location where a hole can be cut 2(a) 9203' 500 2.50 325 4.00 - - 2.63 7.64 -. 40 4.0 -. in the pipe 50 3450 635 83 102 67 194 02 1.9 500 2.75 2.88 4,99 4.00 2.63 7.64 4.29 8.0 7.8 A pressure responsive gasket provides ,mm 920 3450 609 73102 102 67 194 109 3.6 3, the seal 3 (a) 920 500 3.50 3,31 4.50 4.50 2.53 7,53 4.88 5.8 6.5 80 3450 88.9 84 1. 14 114 67 194 124 3.1 3.0 Request Publication 1103 for 1/ (a) 920500 200 453475 475 3-16 970 59 74 76 Mechanical-i cross assemblies 125 X 0 , 3450 50.8 102121 121 80 246 94 3.4 3.4 2(a)-I 500 2.50 4.00 4,75 4.75 316 9.70 4.38 ' 8.2 8.0 Pressure rated up to 500 psi/3450kPa 50 920 63.5 102 121 121 80 246 - 111 -3.7 , 3.6 on steel pipe; also available for use 2½ (a) t 920 Soo ' 2.75 3.63 4,75 4.75 3.16 3.70 4.63 8.3 7.9 with HDPE pipe __ 65 ____ 345069992 11 121 80 246 118 3.8 3.5 76' 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 Sizes from 2 x ½'750 x 15 mm mm 3450 69.9 95 - 121 80 246 118 - 3.6 through 8 x 47200 x 100mm 920 500 3.50 3,81 5.00 4.60 3.16 9,70 5.31 8.4 8.8 60 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 920N 500 2.50 325 4.50 3,17 8.00 3/48 8.0 133. < 50 - 3450 63,5 95 114 81 203 99 3.6 - 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 60 3450 88.9 97 127 - 76 240 135 3.6 - TABLE COP4TINI2ED ON PG. 4 IMPORTANT NOTES: " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated, to one another Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSP'F specifications, @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order, § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in Chine by Tianjin Approvals Company. www.vktaullc.com j(ctauhcr VICTAuLIC (S A REGISTERED TRADEMARK OF V(CTALJL(C COMPANY. 02017 ViCTALILIC COMPANY. ALL RIGHTS RESERVED. REVJJ 11423 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I0 Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 0 .74 0 (i 1x "0,415 9 (1 F 8 •!m. . 'a e 4 Y 4-Z----1 " '' " "' t6i EN O TABLE CONTINUED FROM PAGE 3 1397 y 1 40 /2 920\ 2°O .96 - - 84 209 83 - 25 500 230 3.75 450 3.30 8.23 3.88 9.0 - - 50 3450 63.5 95 4 84 209 99 4.1 - W 6 / (a) 500 175 44 5 3 5".3 379 915 SI 48 ISO >r 32(b) 920,'. 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1/ia 920 500 200 440 5 5 379 915 335 545 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) tu 20' 500 2,50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5,6 50 3450 63.5 111 130 130 96 232 99 2,7 2,5 4 VZ 2 ' -o 500 2.75 4.01 5,13 5,12 3,69 10.51 4.63 8,3 7.6 3450 69.9 110 -. 130 130 94 267 116 3.8 34 76.1rnrn 920 5,90 - 21 339 10,51 4.63 - 8.4 3450 69.9 105 '32 94 267 1183.8 500 350 43 920 550 5.3 3.69 10315319.9 8.4 W 80 3450 88.9 110 140 130 94 267 135 4,5 3.8 4 4(a) t 5 920 500 430 38 7 38 369 - 1051 6.21 101 101 100 3450 114.3 97 146 137 94 267 159 4,6 46 FEMALE THREADED OUTLET ,___________ ' 920N 500 2.00 4.41 5.3 363 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 33 - 2(a) , 500 2.50 4.38 5.13 3.63 9,40 3.88 8.12 Provides a direct branch connection at . 3450 63.5 1(1 130 - 92 239 99 3.6 - any location where a hole can be cut 761 mn 920 500 2.75 4.38 550 513 3.63 9.40 4,63 9.5 9.5 in the pipe ' " 3450 69.9 1(1 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4,31 5.50 5.13 3,63 9.40 5.31 8.1 14.0 A pressure responsive gasket provides ' 80 , - 3450 88.9 110 140 130 92 239 135 3.7 6,4 the seal 1080mm 920 300 4.50 4,45 5.38 3.63 9.40 6.12 - 10,0 3450 114.3 113 137 92 239 155 4.5 Request Publication 1103 for 920 500 450 8 575 - 36 940 625 80 - Mechanical-T cross assemblies 100 3450 114.3 96.80 146 " 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order, with HDPE pipe $ Center of run to end of Fitting. Sizes from 2 x ½/SO x 15 mm. 8 Female threaded outlets are available to SIFT and BSPT specifications. through 8 x 4/200 x 100mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet Is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½' BSPT clearly on order. § Vds approved for fire protection services P LPCB approved for fire protection services IMPORTANT NOTES, 0 Approved for use in China by Tianjin Approvas Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections, www.victaultc.com ,tauiicr VICTAUUC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11024 REVJS CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS slz~ No. ltil-su-31 Dimemlofii 'Height Each C t'mP 4 "fm .1r4 sre '1O ) 'm. A1a 4 Y 31 ," " 'V" , O • I TABLE CONTINUED FROM PAGE 4 651 i Soo 25 920N 1 3 4 - 3 9 275 80 - 3450 381 99 116 96 237 70 36 14 a 920N 500 175 4.43 513 3.79 9.34 3.25 8,4 - - - - 32 3450 44.5 113 130 - 95 237 83 3,8 - W (a) 920N 500 2,00 4A1513 5.13 3.79 9.34 3.25 8,45.4 40 3450 50.8 112 130 30 95 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 53.5 lii 130 130 96 237 99 3.9 2.7 500 2.75 4.01 5.15 5.21 3.63 10.51 4.63 8.6 7.6 76.i mm 920 3450 69.9 110 130 132 92 267 118 3.9 3.4 -Z 3(a) t 0 500 3.50 4,31 5.50 5.13 3,63 10.51 5,31 10,2 8.4 80 920 3450 88.9 110 140 130 92 267 135 4.6 3.8 v 4(6) In 920 500 450 381 575 38 36 105 525 105 84 100 , 3450 114,3 97 146 137 92 267 159 4.8 3.8 t - - 8 x lIlt - 500 275 544 59 625 481 1242 450 5 115 'N 200 50 10 3450 69.9 138 157 159 122 316 114 5.3 5.3 2½(a) 5 500 2.75 5.07 519 5.19 4.81 12.42 4.50 116 11.5 65 920 3450 69.9 129 157 157 122 315 114 53 5.3 FEMALE THREADED OUTLET 920 530 275 25 - 525 - 481 1242 456 116 Mm 3450 59,9 133 - 159 122 315 115 - 5.3 3(a) tx 500 3.50 5.31 6.50 5.50 4,81 12.42 5.31 12.6 1.5 Provides a direct branch connection at 80 920 3450 88.9 - 135 ,½5 165 122 315 135 5.7 - 5.3 any location, where a hole can be cut 4(a) t 920 500 4,50 4.81 - 6.75 638 4.81 12,2 6.25 15.3 12.5 in the pipe 100 34513 114,3 122 171 162 122 315 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides I- Available with grooved or female threaded outlet. Specify choice on order. the seal * Center of run to end of fitting. bequest Publication 11,03 for 8 Female threaded outlets are avaiiable to NPT and BSPT specifications. Mechanical-i cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500psi!3450kPa a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order. on steel pipe; also available for use (b) For 76.1 mm threaded outlet, specify 2½' BSP1' clearly on order. with HDPE pipe § Vds approved for fire protection services o LPCB approved for fire protection services Sizes from 2 x 1/2750 x 1 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4720 x 100mm IMPORTANT NOTES: Style 920 and Style 92051 housings cannot be mated to each other to achieve cross connections, wwwtauIic.com \/ataulsc ViCTAULiC is e REGISTERED TRADEMARK OF ViCTAuLiC COMPANY. 0 2017 ViCTAuLIC COMPANY, ALL RIGHTS RESERVED. 11425 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA How test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T` fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values I Values for flow of water at +60FI+16°C are shown in the table below. Formulas for C91 Values: );:( (J AP = Q2 Where: p = Where: Q= Flow (GPM) Q= Flow (m3lhr) Q = C x AP = Pressure Drop (psi) Flow Coefficient = AP = Pressure Drop (Bar) JJ- J = ç, x K, = Flow Coefficient Exaggerated for clarity Eq.i,af—t Length of 1JIiI*IM 40 Ca(bon Steet Pipe . ½ 0.840 - 2 15 21.3 9.4 -Y~1350 - 1 , 16 20 26.7 37 1 1315 - --.-.- 2' 25 33,7 - ia i'/4 1660 s ,,, 2 6 50 46 32 42.7 42.9 411 i½ 1.900 -- - ii - 53 53 40 983 - 45,4 - 454 2 2.375 1022 112 - - - - 'o 50 603 2 -- -- 96 891 2½ 2.875 2 ' 1/2 -- 19 150 65 73.0 02 128.5 3.000 76.1 mm . 6 itt - 76.1 i38.1 3,500 4 . . '/2 249 - 237 80 88.9 213.4 203.1 4.500 - zO - 2 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0,1 65in 14.2mm. "1" FireLock" Innovative Groove System (IGS) outlet www.victauflc.com ri.tj(ctaulscr vicTAuLic IS A REGISTERED TRADEMARK OF ViCTAULIC COMPANY. 02017 ViCTAuLIC COMPANY. ALL RIGHTS RESERVED. 11026 QEV.H CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T' Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. ListingslApprovals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. cy 21/2-6 2875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2 -4 2.875 - 4.500 All OF - 300 300 - 300 290 - 232 362 65-100 73.0-143 2065 - 2065 2065 1999 1599 2496 - - 21/2-4 2,8i5 - 4.500 AS 300 300 300 290 232 362 65-100 73,0-114.3 2065 - - 2065 2065 1999 1599 2496 6 - 6626 4 10 300 - 300 250 290 232 - 362 150 168,3 2065 2065 1724 1999 1599 2496 6 6,625 - 4 3 30,40 -- 300 330 300 290 - 232 362 150 ' - 168.3 2065 - - 2065 2065 1999 1599 2496 8 8.625 2/2 10,40 400 - - ..-. - - 200 2191 2755 . 1000 - 8 8.625 10 300 - 250 145 - 200 2191 '' 2065 , 1724 - 1000 8 8.625 34 3040 300 - 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DE refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation, VIC-TAP II HOLE CUTTING TOOL FOR 4 8"I100- 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap Il Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve, The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 67150mm and 87200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCD in accordance with safety codes. For more information, refer to publication 24.01. www.vlctauliccam 'j(ctauiic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-9 11027 VechanicaI'P STYLES 920 AND 920N INSTALLATION Reference should always be made to the 100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations, For complete contact information, visit wwwvictauliccom 11.02 J4O REV N UPDATED 17J2017 ictaubc VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 112j STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VIcTAULIC COMPANY. ALL RIGHTS RESERVED. 4tauiicr 1O..52..1 IPS CARBON STEEL PtPE. HOLE CUT PRODUCTS 10.52 FireLock OutletT STYLE 922 DIMENSIONS _Y_ i.- z- 1¼ ½ 1 /l6 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 T 3/4 13A 1.28 1.83 1.10 3.87 2.56 - 1.1 - - - - - - 20 - 30.2 32.5 46.5 27.9 - 98.3 65.0 0.50 W 1 1 1.52 2.18 - 1.10 3.87 2.56 1.2 25 30.2 386 55.4 27.9 98.3 65.0 0.54 1½ 1/2 1 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/~ 13/,6 - 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 310 103.6 65.0 0.54 1 1 3A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 059 2 x ½ 1 3A 1.66 2.19 1.46 - 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 34 13/16 1.64 2.19 1.46 4.60 2.56 1.4 - 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 x ½ 1 3/16 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 4 1 3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137,2 65.0 - 0.73 1 1 3/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 1/2 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 , 139.7 - 65.0 - 0,73 3/4 1 3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 . 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NFl or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com \tauIic vICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 viciuic COMPANY. ALL RIGHTS RESERVED. W152_2 ' EYLG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLocW OutletT STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com 4dirctaulicr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED, 10,523 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV UPDATED 12/2009 /ictsuhlcr vlcTAuuc IS A REGISTERED TRADEMARK OF vICTAuLIc COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Ductile Iron Threaded Fittings SMITH,COOPER Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP U Ductile iron castings conform to ASTM A536 c L us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Fig. 33E3-90° Elbow c®us <? MWRMLISTED Size in Part Number I A in Packing Weight lb inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 358 3006 1.31 70 140 - 0. 1 35E3010 1.50 40 80 0.5 35E3012 1 75- 25 50 1-1/2 3553014 1.94 18 36 1.1 2 35E 3020 2.25 20 18 2-1/2 3553024 - 210 4 6 3.2 Size in Part Nu mber 'A in B in PacklWO WilghT lb Inner I Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 lx 112 35RE3010004 1.26 1.36 70 140 0.4 1x3/4 35R83010006 1.38 1.45 50 100 0.4 1-1/4 x1/2 35RE3012004 1.34 13 35 70 0.5 l-1/4x3/4 35853012006 1.45 1.63 35 70 0.6 1-1/4x1 358E3012010 1.58 1.67 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1,75 30 60 0.6 1-1/2x3/4 358E3014006 1.75 25 50 0.7 1-1/2x1 358E3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 358E3020004 1.60 1.97 18 3 1.0 2x314 - 358E3020006 1.60 1.7 18 36 1.0 -2xI 358E3020010 1.73 2.02 16 32 1.2 2x1-114 35RE3020012 1,90 2.10 12 24 1-3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 358E3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 I 35F3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 I Fig. 35RE'3 - 900 Reducing Elbow Fig. 35T3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 351 3004 1.13, 80 160 0.3 3/4 35T3006 1.31 30 60 0.5 1 351 3010 1.50 25 50 0.7 1-1/4 3513012 1.75 1 10 20 1,1 1-1/2 3513014 1.94 10 20 1.5 2 3513020 1 2.25 6 12 2,4 2-1/2 1 351 3024 1 2.70 4 8 4.3 111 SMITH-COOPER JNTERNAT)NAL® • TOLL FREE I-8-766-0076 • FAX(323)890-4456 • wwwmcoopcom - Size in Part Number A in B in in Packj Weight lb inner Master 3/4x 1/2 35R13006004 120 120 1.22 60 120 0.4 --Ix 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35813010004010 1.50 1.36 1.50 30 60 0,6 1 x3/4 35813010006 1.38 1.38 1.45 25 50 0.6 I x3/43/4 35813010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35813010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 358T3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x112x1.114 35813012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35813012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x3/4x 1-1/4 35R13012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35813012010 1.58 1.58 1.67 15 30 1.0 1-114x1x1/2 35R13012010004 1.34 126 1.53 25 50 0.7 1-1/4x1x3/4 35R13012010006 1.45 1.38 1.63 20 -. 40 0.8 1-1/4xlx1 358T3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35813012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35813014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35813014004012 1.81 1.56 1,88 24 48 1,1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 358T3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-114 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35813014006014 1.94 7.75 1.94 18 36 1.2 1-1/2x1 358T3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35813014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35R13014010006 1.50 144 1.75 16 32 0.9 1-1/2xlxl 35813014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35813014010012 1.82 1.67 1.88 12 24 1.2 - 1-1/2xlx1-1/2 35813014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x 1-1/4 - 35813014012 1.82 1.82 __788 12 24 1.4 1-1/2x1-1/4 x1/2 35813014012004 1.41 134 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x 1-1/4x1 35813014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-114 358T3014012012 1.82 1.75 188 14 28 1.3 1-1/21-1/4x1-1/2 35813014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 149 1.88 10 20 1.5 2x3/4 - 358T3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2x I x2 35813020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35R13020012 1.90 1.90 2.10 8 16 1.9 2'1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 358T3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35813020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35813020014006 1.60 1.52 1.97 10 20 1.4 2x 1-1/2x1 358T3020014010 1.73. 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35813020014012 1.90 1.82 2.10 8 16 1.7 2x 1-l/2x 1-1/2 35813020014014 2.02 1.94 2.16 8 16 1.8 C®uS Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in I B in C in Pac ii Weight lb Inner Master 3/4x1 35813006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 358T3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35813010014 1.80 1.80 1.65 15 30 1.0 1-1/4x lx 1-1/2 35B13012010014 188 1.80 1.82 ' 15 '30 1.2 1-1/4 x 1-1/2 35813012014 1.88 1.88 1.82 15 30 3 1-1T4x2 35B13012020 2.10 2.10 1.90 10 20 1-1/2x1-1/4x2 F 1-1/2x2 ' 358T30i4012020 2.16 2.10 2.02 10 1 pl. 20 35BT3014020 2.16 ' 2.16 ".02 8 16 SMITH-COOPER INTERNATK)NAL • 'TOLL FREE 1-800.16640076 • FAX (3Th)890-4456 9 wwcsrnithcooper.com 112 Size in Part Number A in Packing Weight lb inner Master 1/2 35CP3004 138 200 400 0.1 3/4 C6 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 1' 30 1.2 2-1/2 35CP3024 3.00 9 18 2,2 NI Size in Part Number A in Packing Weight' lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 04 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB30014 1.38 40 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing "Wiight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2-1 35SP3020 1.50 45 1 90 0.6 I c®uS Fig. 35CP3 - Straight Coupling with Ribs LISTED Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb inner Master 1 x 1/2 36RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 -x 3/4-' 35RC3012006 2.06 40 80 0.6 2x 1 (not hex)l 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Fig. 3$U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb inner Master 1 35U3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 - 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2,4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-$00-766-0076 9 FAX (323) 890-445I • %wwsmithcoopercom c®us <> APPROVED LISTED Size in Part Number ___ in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 - 35X 3020 2.25 6 12 2.8 Fig. 35% 3- Cross Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 33006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 1-1/4 35C3012 1.28 70 140 0.4 1-1/2 35C3014 1 1.33 1 50 100 0.5 2 35C3020 1.45 25 50 0.8 2-1/2 35C_3024 1.70 1 18 36 1.6 Fig. 35BC3 - Hewn Clamp J Fig. 35RX3 - Reducing Cross [Size In Part Number [A B Packing [Weight] lb I Inner Master 1-1/4x1 35RX3012010 1.67 158 15 30 [ 1.2 L 1-1/2x1 35R014010 180 - 165 12 24 L 1.4 2 x 1 35RX3020010 202 1 173 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner I Master 3/8 35BC3003 0,75 100 200 0.3 1/2 3C3004 0.75 80 160 0.5 SMfE'Ff -COOPER NTERNATtONAL 9 TOLL FREE -800-7664)076 9 FAX 3Z3 890-4456 9 wwirnithcoopeccom 114 INSTALLATION STEPS .cY411i INTO WOOD & siiJ] JINS7LAT1ON STEPS I:®1Mo]uINTO WOOD & STEELj Insert the appropriate nut driver into a 3/8' or 1/2' portable drill. Insert the SAMMYS Into the #14 (black) nut driver (p/n 8113910). on// should be in a vertical position Push the face of the nut driver tight to the member Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4', 3T, 1/2" or metric all thread rod, bolt stock. (The 1/2' requires the #14$ W red nut dilivm) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for rnaximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8'or 1/2" portable drill. Insert the SAMMYS into the #145 W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4', 3/8", MIt), M8 or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS -JUM INTO CONCRETE:J Using an SOS 250 carbide tip bit ora HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed; install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pro-drilled hole, turn impact/drill unit to drill made and begin insertion. When the nut driver spins freely art the CSTscrew, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4', 3/8", 1/2", or metric all thread rod or bolt stack. (1114SW red nut driver used with 1/2' screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - INTO CONCRETE: 1 Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #258 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (pin 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4', 3/8"or metric all thread rod or bolt stock, Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. .- uIIikt1EiIu11ilM1 PECK MTORWISYSM The nut drivers were designed: with a unique spin-off featurewhich provides fast and safeinslatlation each time. When the faced the driver comes into contact with the material you are installing into continue drilling until nut driver spins free Installation is then complete Warranty requires the use of the appropriate nut driver for installations Made with TeW seIfdriIIing fasteners - no, pre-drilling required. Installs into steel range from 20 gat/ge— lIZ thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the SammysNut Driver with an 18V cordless cirilllckver. -A standard screwgun with a depth sensitive nosepiece should be used to install Teks, For optimal fastener performance, the ecrewgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U$.A. no pr C) Watch a adho damcihatio,, at .: wwwJtwbuIWezcm SAMMYS FOR STEEL #14 Black Nut Driver Part# 8113910 1/4" 8024957 OSIR tOO * 1/4-20*1" TEKS 3 1510 120 gal .03620 ga 3/16' 25 125 1W 8025957 051100 1/414x1TEKS3 446(2a( 036 20 ga 3116 25 125 1/4" 8026957 057150 1/4-14* 1-1/2" TEKS 3 970 (16 ga.) .0X-20 ga 3/15' 25 125 r-114 8027957 DST200 1/4-14 x 2" TEKS 3 46(2159) .03T-20 ga 3/16 25 125 1 114 8030957 18/K 500 12-24*1-1/7 18/KS 5 3125 (3/16") 158'-3/16 1/2" 25 125 3/8 8038957 OSTRI 1/420*1 TEKS3 151(2091) 1500 1475 036"-20 qq 3/16 25 125 <0> 3/81 8037957 DSTR 11/2 1224*1 1/2" TEKS 5 1510 (3/16) 1500 1475 069'46 ga 1/2 25 125 8039957 DS1R5165/1&-18x1i7j02Oga) 1500 1475 036%20 R 3/16 25 125 3/6" 8040957 DST 10 1/4-14x11EKS3 446 (20 (16 qaa .036"-2flga 3/16" 25 125 [ 3/8" 8077925 DST 10-SS 1/4-14x1"IEKS3 970 446 (20 .036"-20ga3/16" 25 125 3/81' 8041957 DST 15 1/4-14*1-1/2" TEKS 3 446 (20 970 (160a) .036.20 ga 3/16" 25 125 3/8' 8078925 05715-55 1/4-14*1-1/2' TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8/' 8042957 05120 1/4-14 x 2" TEKS 3 446 (20 036-20 ga 3/16" 25 125 3/8" 8043957 DST 25 - - 1/4-14x2-1/2"TEKS 446 (20 .036%20 ga 3/16" 25 1251 3/6" 6044957 05130 1/4-14c3"lE}tS3 446 (20 970 (16ga) .03F-20 ga 3/18/' 25 125 3/8'604te57Dr565i8 k1-1/41EKS31500/16'15001475 .126"-1/8"3116"25 ' 125 <S> 3/8' 5046957 18/K 50 12-24 a 1-1/2'IERS 5 0125 (0/137 151117 1473 25V'-114' tl0' 73 173 #14 Sth ed IIJttD tier artt81i49iO F 1/7' 8031925 0512.0 1/4-14*2" TEKS 3 446 (20 ) 970 (16 ga.) .186"-3/16" 1/4" 25 125 1/2" 8033925 OSIR 1.0" 1/4-20 x r TEKS 3 1510 (20 .) .036-2093 3/18/" 25 125 —1/2"8035925 8034925 DSTRS 16 0S15.16 5/16-18*11/4_IEKS 32220 5/16-18x1-1/4"TEKS3 1500_(3/18')_.125"-i/8/"3/16725125 (LO 9a) _036"_20 ga 3/16_25 125 1 /7' 036925 TEK 5.0 1224*1 1/2_tkS5 3125 (/l6) 1883/16__1/2_25125 -inciuties retaining nut SPECIAL NUT DRIVER SYSTEM: The nut dtivere were dedgnedwith a unique spin-offfeature which, provides .a fast and safe installaton each time When the face of the driver comes into contact with the material you are installing into continue drilling unbi nut driver spins free. Instailation is then complete. Warranty requires the uae of the approphata nut ddver for installations Made with Teks selfdh Ding fasteners. no pre-drilling required. L - 110 Installs into steel range from 20 gauge - 1/2" thicknesses. - A standard screwgun with a depth sensitive nosepiece should be used to p r e- r red install Teks. For optimal fastener performance, the screwgun should be a '1 minimum of 8 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces insta)ltion costs. Quick to install using the $ammys Nut Over with an 18V cordless drill/driver. dmonson 7\ Made in the U.S.A. ",wwwitwbuitdex.cornj Rod ••L pa in Max Thickness__ Box Case J 1/4" 8047957 SWD 100 1/4-14x1"1E)(53 1477 )16ga.) •060-16ga 3/16" 25 126 1/4 8049957 SWDR100 1/420s1 TEKS3 1900 (209a) 036 209a 3/16 25 125 3/6" 8050957 $WDIO 1/4-14niTEKS3 1477 (16ga) .060-1698 3/16 25 125 L - 3/8" 8080925 SWO 10-SSI/4-14x1"TEKS3 1477 16ga.) .060"-16a3/16" 25 125 3/6" - 8051957 SWOIS 114-14x 1-1/2TEKS3 - 1477(16ga.) 060-16ga 3)16" 25 125 8052957 SWD2O 1/4-14x2"TEKS3 1477 (l6ga.) .060-1690 3/16" 25 125 3/8" 8053957 SW 516 5/16-180-1/4TEI<S3 2480 (20ga.) .036"-20ga 3/16" 26 125 3/8 8055957 SWDRI 1/420x1TEKS3 1900 (209 1500 1475 g - 3/1 25 5 3/8" 8054857 SWDR1-1/2 12-24x1-1/2"TEKS5 2375 (3/16") 1500 1475 •188"-3/16" 1/2" 25 125 Nutodyier -387 8056957 SWDR5 5/161811/4 2480 (20ga) 1500 1475 rt81149i0 - - - 3/8" 8057957 SWTIS - 12-24x1-1/2"TEI<S5 2375 (3/16") •188"-3/16" 1/2" 25 - 125 "Includes retaining nut Eliminates distortion of threaded rod in sloped roof applications. Accommodates 34/2 tc 12 pitch. Installs into angled z-puriin; allows threaded rod to hang plumb. "Allows 17" deflection from vertical, Made in the USA Wfria do demo ,,buIfeercom #14 Black Nut Driver Part# 8113010 3/8" 8137957 SH-OSTR 1" 3220 (3/16") 1500 1475 .035" 3/16 25 125 i 3/8' 8268957 SHTEK50 12-24x1-3/4" r-- - 1/2" 8270957 SH-TEKS.0 12-24x1-3/4" t. TEKS 5 2368(1/2" steel Vertical) 1306(45" off Vertical) 2281 (3/16" HSS) 1585(3/16" HSS 45" off Vert/cal) 2368(1/2" steel Vertical) 1306(45" oIl Vertical) 2281 (3/16" HSS) 1585(3/16" HSS 45" off Vertical) 1500 (Vertical) 4 3/16 1/2 25 125 850(45" off Vertical) 2-1/2" 3/16" IT 25 125 S A IVllIfl V X-P R E S S Installs into Metal Deck, Purlin, or Tubular Steel The Sammy KPress expands to provide direst vertical attachment in: light gauge steel deck or purlin (22 ga. - 1/8). Installs in seconds with Sammy X-Press Its Tool, saving time & installation costs, Use in applications where access to the bash of the installed fastener is prohibited, is. metal root deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S A, Watch video den nsO'ationi\ %—)wwwJtwbu!WexcomJ 1/4" 8161922 XP 200 Sammy X-Press 200 25(Luminafre) 05& - 850(2W Pe( .027' 940 (2 P98) .029" 2/8" 8150922 XP 20 Sammy1146 (22 ga) 185 (Luminaire) .027" 1475 (C Pipe) .104" X-Press 20 250 (Luminaire) .056, 283 (Conduit & Cable) .029" /500 (4 Pipe) .060" ' ' 3/8" 8153922 XP 35 Sammy 1783'16 a 185(Luminaire) .029 940 (21' Pips) .029" X.Press 35 250 (Luminaire) .056" 1475 (4" Pipe) .104" 416 (Conduit & Cab/e( .059' .125" 25 125 Metal Deck 125" 25 125 Metal Deck .125" 25 125 Purlin r Pre-Pour Structural Concrete 3000 psi - ft 4' 3/8" 8150922 XP 20 Sammy X-Press 1146(22ga) 850(2i4Pipe) 25 125 L _______ .--- _____ Post-Pour Range llLWC535PCF(l) mew Ded PM-Pour Structurat Concr.ta @3089 pet Poet-Pour Range It tWOS 35PCF (Ike! ft'3 JrrrL#4 -ç The Sid erXPt'ess expands to provide Less jobsite materiel needed, horizontal; attachment in: 16ga- 3/16i' steel pudin, tubular steel. • No retaining nut required. Installs in seconds with Sammy X-Press If, Tool, • Provides design flexibility. saving time & installation costs. Made in. the USA. Use in applications where access to the back of the installed fastener is prohibited:: ie, metal roof E(Swxp~ deck, tubular steel, or vapor barrier fabric. QWatclra video dunonoIratiov et wwwJM'buit(texom l 3/8' 8293957 SWXP 35 Sidewinder X-Press 35 1250 01A, Pipe) 1798 (16 ga) 80 (Lumineir) .059' /25' 25 125 Purtn The Swivel XPess allows you to hang plumb in extreme roof pitches: - 89 in z-purfln 45 in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press If Tool, saving time & installation costs. Use in applications where access to the back of the Installed fastener is prohibited. Ia. metal roof deck, tabular steel, or vapor barrier fabric. Less jobsito material needed. No retaining nut required, 'Provides design flexibility. Made in the USA. Watch a video demqnslravon at w#wbufWexcom W!ZMYA$i • . 750 (2" Pipe) 19- > 3/8" 8294922 SXP2O Swivel 179 Vertical (Lumnare) 1061 (22 ga Vert) 80@45"(LLjm•re) .025" 635 2Ppe( .029" .125" 25 125 Metal Deck I I Vert) 203 Vertical (Conduit & Cable) 233 @ 45 (Conduit & Cab/el 1250 (31/2" Pipe) .1 S 3/8' 6295922 SXP 35 X.Press35 250 Vertical lLuntirrairel .029" .125" 28 125 Purtin i558(&9 Off Vert) 500 Vertical (Conduit & Cable) 638 (2" Pipe) 333 @ 89 (Conduit & Cable) Swivel 112" 8272967 SXP2.0 1061 (22 ga ert) 25 125 Metal Deck It .027" .125" Xs0 Swivel 1675(16gaVert) 1/2 8271957 63,5 X-Press35 1558l85 Off Vert) .060 .125" 25 128 Purin 1A!7IlTk.,a Product Features / ,', I • The Sammy X.Pvess expands to provide L direct verttcalattachment in: / . ." - z-pudin (18-16 gauge) metal deck (22-16 gauge) ' \j jjj Made in the U.SA ç Watch a video demons TEITm1. •1lU.1I eta! 8194910 uxtr Universal X-Press It Tool 8152910 - - 1fPI3 - 25/840d116it - . -.---- I 'Tent Includes: Sleeve, Sit Receiver; /tex.Wrench, and 26/64' Drill Bit I APPROVALS 8007951 GOT 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 130120 3/811 Vertical 2-1/2" 850 1-112" 4" 1475 1-1/2" 8068925 135120-OS 3/8" Vertical 2-1/2" 850 1-1/2" 8010057 GOT 30 3/8" Vertical 4" 1500 1-112" 4' 1475 1-1/2" 8009925 135725-380 3/8" Vertical 4" 1500 1-1/2' 8022925 SWG 25-380 318" Horizontal 3-1/2' -4"' 1500 1-1/2' 8021957 SING 20 3/8" Horizontal 2-1/2" -3"" 1050 1-1/2" 8073925 SWG 20-OS 3/8" Horizontal 2-1/2" 850 1-1/2' 8269957 SH-G$T/CST 20 3/8' 45" Angle off Vertical 211/2" 850 111/2" 8269957 St+-G$T/CST 20 3/8" W Angle off Vertical 4" 1500 1-1/2" 8139957 SH-13S120 3/8" 17" Angle off Vertical 1050 1-1/2' 4" 1475 1-1/2" 8038957 OSIR 1 3/8' Vertical 1500 .035" 4" 1475 105" 8037957 OSIR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039951 OSTR516 3/8" Vertical 4" 1500 .037' 4" 1475 .105" 8045957 051516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEKSO 3/8" Vertical 4" 1500 .250" 4' 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037 4" 1475 .060 8056957 SWDR 516 3/8' Horizontal 4 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8' Horizontal 4" 1500 .037' 4" 1475 .060" 8137957 SH-OSTRI 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 i05" 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 70" AngIe off Vertical 4* 1500 - 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 7 946 4" 1475 J05" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 1 475 125" 8294922 SXP 20 318" Vertical or up to 45" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89" 31/2" 1250 .060" 2" 635 .028" 8293957 SWXP 35 3/8' Horizontal 3-1/2" 1250 .060" SAN3/YS FOR CONCRETE - PPE HANGER 6059957 COT 20 3/8" Vertical 4" 1475 3000 8061957 5WC20 3/8" Horizontal: 4" 1475 3000 8150922 XP 26 3/8" Vertical 2-1/2" 850 Pre-Pout Structural i3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranos II LWC 35 PCF (lbs/ft3) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .021" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SW 20 Vertical 170. - 80 .027" 8295922 SXP 35 3/9" Vertical 250 .060" 90" 80 .060" 8293957 StiVXP 35 3/5" Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027' Max trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max4 trade size. EMT & 6 trade sze RMC. IMC, and rigid PVC conduit 8294922 SXP 2O 3/8" Vertical 283 .021" Wax 4 trade size EMT, RMC, and lMC&5 trade size rigidPVCconduit 8295922 SXP 35 3/8" Vertical 500 .060' Max4 trade size. EMT & 6 trade aze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8 Horizontal 500 060 Max 4 trade size EMT &6 trade san RMC MC and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8' Onto Vtrrti Rod UL Ustd 40.16- Cable Hanger, Cat. No. C12000 Plenum Rated, Complies wl NEC Standards Gau.No. . gia. 20ga. 18 0a, 160a. 14g. l2ga. 118" 3/18" 1/4' Nominal Decimal EquIvalent .030 .035" .048" .060" .078" .105" .125" .188" .250' 'SWG 25-300 Maximum pipe size in composite wood joistatowed by UL in 3"112' UL compliance with NEC Standards. "SWG 25-380 Maximum pipe size in snort timber or joist allowed: by UL is 4' UL and FM teats were performed In compliance with NFPA 13 Standards. '*SVVG2i) Maximum pipe size in composite wood joint allowed by UL all-lIZ" Festering requirement 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by llLwere tested in plate steel that measured .188" and .118". Subsequent testing was done for z-puriin applications in May 1997 using (.037") cr20 gauge steel. Most recently in 2008, testing with the new Sammy X-Prese was completed using (.0300) or 22 gauge steel metal deck. SammyO Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, ft should be noted that our sell-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at w.itwbuildeic.corn Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvlronmontaV For attaching or anchoring in high vibratory environments special care should be taken not just for building attachments but also for the hangers or assemblies being supported Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite (cist. UI. testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss Sammy CST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drili pilot We 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole size GSTZO .182" 1/8' GS125-380 280" 712 SWG 20 182" //5" SWG 25380 ,280 7132" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAINEC Standards All UL and FM testing complies with MFPA 13 and NEC standards. Check with your Local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com 0-- - < ~.8- > -LIMA CSSU(T it CASE nitwit atiOunOssiiaO,O"sn Technical Drawings Technical drawings are available and can be downloaded atwww.itwbuildex.corn in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products Contact Information Technical Assistance; (800) BUILDEX Option #6(x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information 3.3.7 Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. Listinas/Aoorovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor Independent code evaluation IBC®/ lRC® 2015 IBC®/ IRC® 2012 IBC®/ IRC® 2009 IBC®/ IRC® 2006 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbft in. 1/4 Nominal embedment hnorn in. 1-5/8 2-1/2 Effective embedment h, in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T I. ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 Tinst is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa-rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench se €anch - In h00,0 - h0 - Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2'3''5 Nominal Nominal Tension - 4N Shear - On anchor embed. f = 2,500 psi f = 3,000 psi f = 4,000 psi f' = 6,000 psi f = 2,500 psi f = 3,000 psi I0 = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 / (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete! pullout failure in cracked concrete 1,2,3,4,6 Nominal Nominal Tension - N0 Shear - anchor embed. f' = 2,500 psi f = 3,000 psi f' = 4,000 psi f = 6,000 psi f = 2,500 psi f' = 3,000 psi f' = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1/4 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete Only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A0 = 0.68; for all-lightweight, A0 = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - aN, = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aN',O, = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear4 Seismic shear' diameter thread diameter cpN in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension 4N = (PA NfOO as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with <0.64A 0 tta as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with cpVm 5 p 0.60 A0e f as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete',' Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 uncracked concrete 'AN 'RN lAy fRy fRy I IV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) 1 (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 _______ _______ 0.70 0.63 0.68 0.88 n/a --' 3-1/2 (89) 0.99 0.80 _______ _______ 0.71 0.64 0.76 0.92 n/a .9. E 4 (102) 1.00 0.85 1 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 1 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 g' _9 (229) 1.00 0.86 as 10 (254) 0.89 0. 11 (279) 0.93 12 (305) 0.97 - 14 (356) 1 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 cracked concrete 'AN 'RN 'AV fRy IRV fl, Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) 1 (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 1 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 1 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 (152) _6 1.00 0.86 0.74 0.98 7 (178) - 0.92 0.78 1.00 - 8 (203) 0.98 0.82 9 (229) 1.00 0.86 a 10 (254) 0.90 11 (279) 0.94 ______ ______ 12 (305) 0.98 - 14 (356) 1.00 +--. 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design. use Hilti PRIORS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f., assumes an influence of a nearby edge. If no edge exists, then fv = f. 4 Concrete thickness reduction factor in shear, f, assumes an influence of a nearby edge. If no edge exists, then fv = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilt! KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5.6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - cpN Shear - V,, Tension - pN Shear - anchor thread embed. f'= 3,000 psi f= 4,000 psi f'= 3,000 psi 4,000 4,000 psi 3,000 3,000 psi f= 4,000 psi f',= 3,000 psi f', = 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - 4N Shear - V,, Tension - 4N Shear - 4V0 anchor thread embed. f= 3,000 Ps f'= 4,000 psi f'= 3,000 Psi '= 4,000 psi f'= 3,000 psi f'= 4,000 psi f' 3,000 Psi r= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 ______ (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1/4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) 2-1/2 605 700 915 915 635 735 915 915 UNC (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hiiti, inc. (US) 1-800-879-8000 1 www.us.hiiti.com I an españoi 1.800-879-5000 1 Hiiti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of HUti KWIK HUS-EZ I (KH.EZ I) In soffit of concrete over steel deck floor and roof assemblies r — Mfr,. /4 .-'). •_J_ __i ',--. 'J_l 1 Min, ,3,O00paisar1d-lghtwaigMi(" or In Cl) Upper C 10 flute Min. 4-1/2"' Anchor Flute WOO Lower Mm, 1-1/4 Mm. 12 (typical) (ridge) Minimum 20 gauge steel clack 1 Anchors maybe placed in the tipper or (ower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design 3.3.7 Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I r1 carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile Shear4 Shear' diameter diameter N V, Vweq in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = AON Ct f R as noted in GSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V, <A 5 mt, 0.6 futa R as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V, <A 0 Os 0.6 f R as noted in GSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.ua.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 wwwhilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 H Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.314 Anchor O.D. d a in. 1/4 (mm) (6.4) Effective embedment h el in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 2-1/2 in. 1-5/8 (mm) (41) (64) Minimum concrete thickness 4-1/8 h in. 3-1/4 rnin (mm) (83) (105) Critical edge distance C, in. in. 2.00 2.78 (51) (71) Minimum spacing at critical edge distance 5min,cac in. 1.5 (mm) (38) Minimum edge distance in. 1.50 Cmin (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 (mm) (51) (73) Minimum specified ultimate strength psi 125,000 (N/mm2) (862) Effective tensile stress area A in 0.045$05 (mm2) (29.0) Steel embed, material resistance factor for reinforcement 4 - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension Nsa lb 3,370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear V lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V r5q (kN) (1.5) Factored steel resistance in shear V lb 725 D.7.1.2 3/8-16 UNC internal thread Sar (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V,eq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k5 - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 Yc - 1.0 D.6.2.6 Anchor category - - 1 D.5.3 (c Concrete material resistance factor (Pc 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete' Npraner lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete Nprçr lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete Npr lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015. tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex 0 section 0.2. For all design cases, 4J = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k50r) or uncracked concrete (k 5,) must be used. For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qc.p = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in uncracked concrete "2'3'4'5 Nominal Tension - N Shear - V __________ f = 20 MPa f' = 25 MPa f = 30 MPa f = 40 MPa f' = 20 MPa f'C = 25 MPa f' = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed, embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in cracked concrete' 2,3,1,s Nominal __________ Tension - N Shear - V, f = 20 MPa I,, = 25 MPa f'c = 30 MPa f'c = 40 MPa f = 20 MPa f, = 25 MPa f', = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by k as follows: for sand-lightweight, AC = 0.68; for all-lightweight, A = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck"2'3'4'5'6'7 N Installation in lower flute Installation in upper flute Nominal Tension - N Shear - Vr Tension - N Shear - V, Nominal internal Nominal anchor thread embed. = 20 MPa f' = 30 MPa f' = 20 MPa IC = 30 MPa f Ic = 20 MPa f' = 30 MPa f', = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWlK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck'Z34SS78 N Installation in lower flute Installation inupper flute Nominal Tension - N r Shear - V, Tension - Nr Shear - Vr anchor thread embed. = 20 MPa IC = 30 MPa IC = 20 MPa IC = 30 MPa f' = 20 MPa f = 30 MPa IC = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) See Section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hflo,C (nominal embedment). Tabular value is for lightweight concrete and no additional reduction factor is needed. No additional reduction factors for spacing or edge distance need to be applied. Comparison of the tabular values to the steel strength is not necessary. Tabular values control. Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by ctN = 0.75. For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 U 1-5/8NC 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hifti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete Danels1'2 Hanger rod size Mm. effective embedment h ef in. Allowable load3 Ultimate load Tension lb Shear lb4'5 Tension lb Shear lb 4.5 1/4-20 UNC 1-3/8 455 1 485 1,810 1 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ls>. Shear design values should consider the screw or threaded rod steel strength. Figure 3. Installation of Hiltt KWIK NUS-EZ I (KH.EZ I) In hollow core concrete 3.3.7.4 Installation Instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty / box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 13/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 13/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hihi.com I en espanol 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1A6 3/4 1 7116 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13A6 11/4 1 7116 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 1½ 1¼ 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8' rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam, (Beveled lip allows hanging from top flange where clearance Is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe 1/2" rod will support 1/2" thru 8" pipe Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines, Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved Seismic Restraints System @ 03 imin OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737,5599 • FAX: 951.737.0330 CUSTOMER SERV CE • 800.786.5266 WWw.t01COCOm Fig. 25 - Surge Restrainer c®Us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping Into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9,23.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 314" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Component of State of California OSHPD Approved c 1k us im Seismic Restraints System Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs, Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), Incl uded in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD), For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 - 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879. PR: 951.737.5599' FAX: 951.737.0330 CUSTOMER SERVICE P800.180.5266 www.Wlco.com flg. 200.2112 to 200-8 Pg. 200 Fig. 2005 &ipeingrs Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Une Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Une Fig. 0317ONFF 0@ 03 Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig, 0317011FC) UUM Fig. ZOOS - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to 090 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation, Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily " installed around pipe. For hanger with non-captured nut order Fig. 200S. 21/2" (65mm) thru 8" 1200mm Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig, 200.1 2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel , materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size \\ ' Designed to meet or exceed requirements of Fig. 200C Fig. 200F - (1 -9 Ewa 1,40 t3 200 1/2 1/2 ' (15) I8'-16 31/8 (79.4) 2/8 (66.7) Ii (5.0) 200-/4 3/4' (20) I8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1° (25) f"-16 3/8" (85.7) 2/a (66,7) 12 (55) 200_11/4 1 11/4' (32) f8'-16 33/4w (94.0) 24" (73.0) 13 (59) 200_11/2 11/2' (io) /11-16 3f ° (98,4) 2/a (73.0) 14 (6.4) 200-2 2 (50) I8'-16 4112" (114.3) 3" (76.3) 15 (6.9) 200_2112 21/2" (65) 1a'-16 5/8' (142.9) 41/8" (104,7) 27 (12.3) 200-3 3' (75) I 1-16 518" (149.1) 4° (101,6) 29 (13.3) 200_31/2 31/2" (90) /8°-16 7i" 1187,31 51/4" (133.3) 34 (15.6) 200-4 4 (100) I'-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"_13 91f8" (231.8) 6114' (158.7) 66 (30.2) 200-6 6' (150) 112"..13 101/8' (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) t/2".13 13'/a" (333,4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in rniFirneters unless otherwise specified. - ------ - COOPER B-Line Fig, 200.21/2 to 200-8 ai owes IIimgs. I Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - /2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 0/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe ' types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds It securely in hanger before installation, Adjusting nut is easily removed. . -- - Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) jg 90- to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)), Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 107 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650 OF (343"C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size I / Designed to meet or exceed requirements of FM DS 2-0. 200M8-1/2 1/2" (15) M8 3/8" (79.4) 2/8" (66,7) 11 (5.0) 200M10-1h 1/2" (15) M10 31/8" (79.4) 2I8" (66.7) 11 (5.0) 200M8-3/4 14" (20) M8 3Ve" (79.4) 21/2" (63.5) ii (5.0) 200M10-3/4 3/4" (20) M10 31/8' (79.4) 21 /2' (63.5) 11 (5.0) 200M8-1 1" (25) M8 3/8" (85.7) 218" (66.7) 12 (5.5) 200M1-1 1" (25) Mb - 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-1114 11/4" (32) M8 33/4" (94.0) 2/8' (73.0) 13 (59) 200M10-11/4 11/4 (32) M10 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200M8-1112 11/2" (40) M8 37/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 1112" (40) M10 37/8" (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 21 (50) MB 41/2" (1143) 3" (76.3) 15 (6.9) 200M10-2 (50) M10 4/2" (114.3) (76.3) 15 (6.9) 200M-2112 21/2" (65) M10 5/8" (142.9) 0f8" (104.7) 27 (12.3) 200M-3 3" (75) M10 57/8" (149.1) 4" (101,9) 29 (13.2) 200M-31/2 31/2" (90) M10 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 41 (100) M10 73/8" (187.3) 5" (127.0) 35 (16.9) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6" (150) M12 101W (257.2) 6I4" (171,4) 73 (314) 200M-8 8" (200) M12 131/6" (3334) 8f4" 1 (222.2) 136 (62.3) All dimensions in charts and on drawings are in Inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. -- - -1 . COOPER B-Line I fn Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier toads than is normally intended for the nominal hanger size. Used extensively to support trapeze Installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8-16 or 1/2"..13 adjusting threaded ring nut, Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & $P-58, Type 10. Maximum Temperature: 650"F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. i co 1~~ r ' 2" (50) /8-16 4/16 (115,9) 3/32° (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2"_13 423/32" (119,8) 3/8' (85.7) 45 (20.4) 200H-2112-318 2112" (69) /811-16 5/1' (134.9) 3/32' (94,4) 59 (26.7) 200H-21/2-1/2 21/2° (65) 1/2°..13 515/32" (138.9) 37/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4' (146.0) 3i32' (97.6) 63 (28.6) 200H-3-1/2 1/"_13 5/6" (1481) 3/32" (100.8) 60 (27,2) 200H-4-3/8 4" (100) /81-16 6/a' (174.6) 4/1" (112.7) 76 (34.5) 200H-4-1/2 ° 1/2"..13 71/32" (178,6) 1 419/32" 1 (1116.7) 1 73 (33.1) Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 All sizes are UL Listed to support up to 8° pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions In charts and on drawings Rrp "inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line L e ME , Jff i a7s a - Gjwam F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. r Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ ° System Compatible Program* Certified to NSF/ANS/Std 61 -G *ci *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. I 3198 UONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicalon is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. N' © 2012 Fire Protection Products, Inc. FPPf°, LubeFif° are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Master°, RowGuard Gold' and Co,zan° are registered trademarks of Noveon IP Holdings Corp. MADE I U.S.A. sae F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. - 3198 LIONSHEAD AVE ' CARLSBAD, CA 92010 I TEL + 1760 599-1168 1 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPP1, LubeFif5 are registered trademarks of Fire Protection Products, Inc. FBC', BIazeMaste,, FlowGuard Go/d5 and Corzan® are registered trademarks of Noveon IP Holdings Corp. kA MADE IN U.S.A. H Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flarneguard® pipe and fittings. - iTibrtewdiiJIGi'Ee:a:dI@JtL[iigT@I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. WW 0 2013 FireProtection Products, Inc. FPPF, ThreadFit are registered trademarks of Fire Protection Products, Inc. LA KAMM Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. L 3198 LIONSHEAD AVE CARLSBAD, CA 92010 ; TEL +17605991168 I FAX + 1800 344-3775 Installation ThreadFite can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid, Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREc, a 24-hour emergency hotline. They may be reached at 1 800 424-9300. I + 1 800 344-1822