HomeMy WebLinkAbout3200 LIONSHEAD AVE; ; AS160063; Permit11/17/21, 11:31 AM AS160063 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160063 Job Address: 3200 LIONSHEAD AV Permit Type: SPRINK Parcel No: 2218811100 Lot #: 0 Status: ISSUED Applied 3/8/2016 Approved: 3/16/2016 Reference No.: Issued: 3/16/2016 PC #: Inspector: Project Title: LIONSHEAD DEMISING WALL T.l.: DEMISING WALL AS PART OF WAREHOUSE Applicant: INDUSTRIAL FIRE SPRINKLER CO INC 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 619-266-6035 Owner: NINOS I BURKE LANE L L C C/O BURKE REAL ESTATE GROUP 260 BAKER ST E #100 COSTA MESA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 1/1 Bulletin 909 Rel iab ® Model N25 (SIN RA0912) e Early Suppression Fast Response Sprinkler Product Description The Reliable Model N25 Early Suppression Fast Re- sponse Sprinkler (ESFR/Quick Response Storage Sprin- kler) is intended for use against severe fire challenges. This sprinkler is designed to respond quickly to growing fires and will deliver a heavy water discharge to 'sup- press" rather than "control." Note: The Model N25 ESFR sprinkler utilizes a levered fusible alloy solder link in either a 165°F (74°C) or a 212°F (100°C) rating. FM Global considers this a "Quick Response" storage sprinkler for use per FM Data Sheet 8-9. The sprinkler has a Nominal K Factor of 25.2 (metric 362) and will deliver approximately 98 gpm (371 L/min) of water at 15 psi (1 bar). The smaller deflector and frame provide a broad, very symmetrical, hemispherical pattern capable of sup- pressing fires between sprinklers in high storage height areas and at the same time retaining a high momentum central core to penetrate and suppress fires occurring directly beneath the sprinkler in low storage height ar- eas. The N25 ESFR sprinkler is also less susceptible to damage due to smaller deflector and frame design. The lighter N25 ESFR passed rough use and abuse test in the labs without plastic protectors. Application and Installation The Model N25 is an ESFR sprinkler is intended for installation in accordance with NFPA 13 and is a OR Storage Sprinkler for use in all FM Loss Prevention Data Sheets as well as approval of the Authority Having Ju- risdiction. The Model N25 ESFR sprinkler is designed for ceiling only sprinkler system with no in-rack sprinklers required. Protection of (but not limited to) most encapsulated or non-encapsulated (including cartoned unexpanded) plastics. Model N25 ESFR is also use for protection of cartoned exposed expanded plastics as well as some storage arrangements of rubber tires, rolled paper, and aerosols. ASI 60063 3200 LIONSHEAD AV Model N25 ESFR Sprinkler Design Criteria General guidelines: Sprinkler Position: Pendent, align frame arms with the pipe. Deflectors should be parallel with the ceil- ing or roof. System Type: Wet Pipe Systems Only Maximum area of coverage: 100 ft2 (9.3m2), greater coverage area are allowable in some cases. Minimum area of coverage: 64 ft2 (5.8m2) Maximum slope ceiling: 2/12 pitch (9.50) Maximum spacing: 12 ft (3.7m) for building heights up to 30 ft (9.1m) and 10 feet (3.1m) for building heights greater than 30 ft (9.1 m) Minimum spacing: 8 feet (2.4m) Deflector distance from walls: At least 4 inches (102mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Deflector to Top of Storage: at least 36 in (914mm). Deflector to ceiling Distance: 6 - 18 in (152 - 457mm). Center Line of Thermal Sensing Element To Ceiling Distance: 4 - 17 in (101.6 - 425mm). Listings and Approvals 1. FM Approved as a quick response storage sprinkler. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Sprinkler Maximum Ambient Sprinkler Classification Temperature Link Frame Temperature Approvals Identification I Color Color OF OF Oc (SIN) Oc Number Ordinary 165 74 Black Uncolored 100 38 FM RA0912 Intermediate 212 100 White White 150 66 FM Material Data: Frame Deflector I Load Screw Lever I Strut I Link I I Cap I I Washer I I Kick Spring Assembly J I Brass Bronze Stainless Stainless Stainless Beryllium Nickel, Brass Beryllium Stainless Steel Steel Steel Soldered Nickel I Steel 2/ ) / T (H H L R' E - L L -----1--_____ - - I - I L \ -. F IlIF IFPIN! LI-!I'. Al Ei"BLY 't flAP U I- L P U / HH F'EFLEflTUR P3 [3 Fig. 1 Storage Type NFPA FM Open Frame (that is, no solid shelves) Refer to NFPA 13, Single, Double, Multiple-Row, or Portable Rack Storage Chapters 16 and 17. Refer to FM 8-9. of Class l-IV and Group A or B Plastics Solid File or Palletized Storage of Class l-IV Refer to NFPA 13, Refer to FM 8-9. and Group A or B Plastics Chapters 14 and 15. Idle Pallet Storage Refer toNFPA 13, Refer to FM 8-24. Chapter 12. Rubber Tire Storage Refer to NFPA 13, Refer to FM 8-3. Chapter 18. Rolled Paper Storage (Refer to the standard) Refer to NFPA 13, Chapter 19. Refer to FM 8-21. Flammable Liquid Storage (Refer to standard) Refer to NFPA 30. Refer to FM 7-29. Aerosol Storage (Refer to the standard) Refer to NFPA 30B. Refer to FM 7-31. Automotive Components In Portable Racks Refer to NFPA 13, Refer to FM 8-1 and 8-9. (Control mode only; refer to the standard) Chapter 20. TABLE 1 COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL ESFR-25 PENDENT SPRINKLERS 3. Installation Data Sprinkler Type Thread Size "K" Factor Maximum Working Finish US I Metric Pressure Pendent Only 1" NPT 25.2 362 (Ri) 175 psi (12,1 bar) Bronze Maintenance The Model N25 ESFR Sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinkler with soap and water, ammo- nia or any other cleaning fluid. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare. sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging until used, to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Once operated, automatic sprinklers cannot be reassem- bled and reused. New sprinklers of the same size, type and temperature rating must be installed. A cabinet of re- placement sprinklers should be provided for this purpose. FENCFI FLAT - IlL APL L85 i7IIlI: / /i l 'T 41ll1 I lal1 / I IIEFL[CTR \\ \TL'1 /1 N —rPAr.IE AR;4Y i55 39.3MTl ifljrlflhflTJ T(i •iT DIL.— 909F'301 Model N25 ESFR Sprinkler Specification Sprinklers shall be Early Suppression Fast Response (ESFR) pendent suppression mode sprinklers specifically tested and [FM Approved] for commodity storage applica- tions. Sprinkler frame and deflector to be of bronze con- struction. Fusible link assembly shall utilize the strut and lever principle of operation with approved fast response black-painted or white-painted beryllium-nickel thermal element. Water seal shall consist of a Teflon-coated Bell- ville spring washer and brass cap assembly containing no plastic parts. ESFR sprinklers shall have a nominal K-factor of 25.2 with 1" NPT threaded end connections. Sprinkler temperature rating shall be [Ordinary 165°F (74°C)] [Inter- mediate 212°F (100°C)]. Link Assembly Frame Arm IN Model N wrench Fig. 3 - Model N Wrench Use only the Model N sprinkler wrench for removal and installation. Any other type of wrench may damage the sprinkler. Note: When handling sprinklers, hold sprinklers only on frame arms and do not apply any force on the link as- sembly. Sprinklers should be tightened between 22 - 30 ft-lbs (29.8 - 40.7 Nm) torque. Sprinklers not tightened to recommended torque may cause leakage or impairment of the sprinkler. Damage sprinklers must be replaced im- mediately. Ordering Information Specify: Temperature rating Thread type 1" NPT or ISO 7-191 Fig. 2 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. JQ Recycled Re (800) 431-1588 Sales Offices Paper liabl (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 10/13 P/N 9999970454