HomeMy WebLinkAbout5900 LA PLACE CT; ; AS160217; PermitCity of Carlsbad
Sprinkler Permit
Permit No: AS 160217
Job Address: 5900 LA PLACE CT
Permit Type: SPRINK
Parcel No: 2120620500
Lot #: 0
Reference No.:
PC #:
Status: ISSUED
Applied 7/22/2016
Approved: 7/22/2016
Issued: 7/22/2016
Inspector:
Project Title: 5900 LA PLACE COMMONS LOBBY T.I.: ADD/ REMOVE &
RELOCATE PENDANT SPRINKLERS PER NEW RCP LAYOUT
IN TYPE I-A NON COMUBSTIBLE CONSTRUCTION. ADD (6)
NEW STP RESPONSE PENDENTS IN LOBBY AREA DUE TO
NEW HARD LID CEILING.
Applicant:
WESTERN FIRE PROTECTION
13630 DANIELSON ST
P0 WAY CA 92064
858-513-4949
Owner:
BOI CARLSBAD L L C
C/O TAX ADMINISTRATION
555 E LANCASTER AVE #100
RADNOR PA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
303 0 303 0
NEVA
Western Fire Protection Inc.
Material Submittal
La Place Commons Lobby Areas
5900 & 5950 La Place Court
Carlsbad, CA
A8 160217
5900 LA PLACE CT
AS1 60218
5950 LA PLACE CT
13630 Danielson Street • Poway, CA 92064 • Phonc. u, -
rc Li &WJ.
IN kII'1k
DESCRIPTION AND OPERATION
STANDARD RESPONSE A U TOMA TI C SPRINKLERS
GL SERIES
UPRIGHT• PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
The Globe GL Series Sprinkler is a low profile yet
durable design which utilizes a frangible glass ampule
as the thermosensitive element. While the sprinkler
provides an aesthetically pleasing appearance, it can
be installed wherever standard spray sprinklers are
specified. This sprinkler series is available in various
styles, orifices, temperature ratings and finishes to
meet varying design requirements.
The heart of Globe's GL Series sprinkler proven
actuating assembly is a hermetically sealed frangible
glass ampule that contains a precisely measured
amount of fluid. When heat is absorbed, the liquid
within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal
pressure within the ampule exceeds the strength of the
glass causing the glass to shatter. This results in water
discharge which is distributed in an approved pattern
depending upon the deflector style used.
TECHNICAL DATA
See reverse side for Approvals and Specifications.
'Temperature Ratings - 135°F (57°C), 155°F (680C),
175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C)
.500°F (260°C) Available Upon Request Without Approvals
.Water Working Pressure Rating - 175 psi (12 Bars)
Factory tested hydrostatically to 500 psi (34 Bars)
Maximum low temperature glass bulb rating is -67°F (-55°C)
Frame - bronze • Deflector - brass • Screw - brass
Lodgement Spring - stainless steel
Bulb seat - copper • Spring - nickel alloy • Seal - teflon
Bulb - glass with glycerin solution, 5mm size
UPRIGHT CONVENTIONAL
PENDENT VERTICAL
SIDEWALL
wc ff
HORIZONTAL LPC/CE
SIDEWALL HORIZONTAL
SIDEWALL
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
AVAILABLE N.F.P.A. MAXIMUM CLASSIFICATION SPRINKLER TEMPERATURES BULB COLOR CEILING TEMPERATURE
ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C
INTERMEDIATE 175°F/200°F 79°C193°C YELLOW/GREEN 150°F 66°C
HIGH 286°F 141°C BLUE 225°F 107°C
EXTRA HIGH 360°F 182°c MAUVE 300°F 149°c
ULTRA HIGH 500°F 260°C BLACK 475°F 246°C
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583. FAX 989-846-9231
JULY 2012 A-65 BULLETIN GI-5661, REV. #6
STANDARD RESPRONSE
A UTOMATIC SPRINKLERS
GL SERIES
UPRIGHT' PENDENT' VERTICAL SIDEWALL
HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE)
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES
2.8 (39 metric) 1/2' NPT 2 1/4 (5.7 cm)
4.2 (59 metric) 1/2 NPT 2 1/4' (5.7 cm) Factory Bronze
Chrome
5.6 (80 metric) 1/2 NPT 2 1/4' (5.7 cm) White Polyester
7.8 (111 metric) 1/2 NPT 2 1/4" (5.7 cm) Black Polyester 2'3
Wax Coated 2.3,4
8.1 (116 metric) 3/4' NPT 2 7/16" (6.2 cm)
METRIC CONVERSIONS ARE APPROXIMATE
1 HORIZONTAL SIDEWALL IS 2 9/16'.
2 FINISHES AVAILABLE ON SPECIAL ORDER,
AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER.
WAX COATING cULus LISTED UP TO 200"F ONLY,
APPROVALS
STYLE SIN K HAZARD' 135"F 155"F 175"F 200"F 286 "F ""360"F "500"F cULus FM LPC CE NYC- DOB
MODEL FACTOR 57"C 68"C 79"C 93"C 141"C 182"C 260"C MEA1O1-92-E
GL2861 2,8 LH X X X X X X X X -- - --- X
GL4261 4,2 LH X X X X X X X X .- - x
UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X X
GL8161 7.81 ALL X X X X X X X X - - - X
GL8164 8,1 ALL X X X X X X X X X X X X
GL2851 2,8 LH X X X X X X X X - - X
GL4251 4,2 LH X X x X X X X X - - -- X
PENDENT GL5651 5.6 ALL X X X X X X X X X X X X
GL8151 7.81 ALL X X X X X X X X X - --- X
GL8156 8,1 ALL X X X X X X X X X X X X
VERTICAL GL5675 5.6 LH X X X X X X X X X - -- X
SIDEWALLt GL8176 8,1 LH X X X X X X X X - - - X
GL2870 2.8 LH X X X X X X X X - - -- X
GL4270 4.2 LH X X X X X X X X - - - X
HORIZONTAL
SIDEWALL GL5670 5.6 LH/OH X X X X X X X X X - -- X
GL5671" 5.6 LH/OH X X X X X X X -- - X X -
GL8171 8.1 LH/OH X X X X X X X X - -- --
CONVENTIONAL GL5668
FGL8169
5.6 LH/OH X X X X X X X - - X X
(OLD SrytE) 8.1 LH/OH X X X X X X X --- - X X
SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS.
§ HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING,
FM APPROVED 4" TO 6" BELOW THE CEILING.
"INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS.
** 360"F NO FM APPROVALS
ALL: ALL HAZARDS
OH: ORDINARY HAZARD
LH: LIGHT HAZARD
1/2" NPT PENDENT VERTICAL SIDEWALL 6' MIN. SPACING.
UPRIGHT VERTICAL SIDEWALL UL 9' MIN. SPACING.
* 500"F AVAILABLE UPON REQUEST WITH NO APPROVALS.
ORDERING INFORMATION
SPECIFY
Quantity • Model Number • Style
"Orifice • Thread Sizes . Temperature Finishes desired
"Quantity - Wrenches - P/N 325390 (1/2); P/N 312366 (3/4")
r EL\ vz L. 'fl ±5'J • T' J
1I]IM!i:i
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its own
manufactured products found to be defective in material
or workmanship for a period of one year from date of
shipment.
For specific details of our warranty, please refer to
Price List Terms and Conditions of Sale (Our Price List).
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583 FAX 989-846-9231
1-800-248-0278 www.globesprinkler.com
JULY 2012 PRINTED U.S.A. BULLETIN GL5661, REV. #5