Loading...
HomeMy WebLinkAbout2701 LOKER AVE W; ; AS160022; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160022 2701 LOKERAV Job Address: WEST Permit Type: SPRINK Parcel No: 2090812200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 2/1/2016 Approved: 2/10/2016 Issued: 2/10/2016 Inspector: Project Title: PALOMAR CREST SPEC STE 290 TI: INSTALL NEW ARM- OVERS, PENDENT, AND UPRIGHT FIRE SPRINKLERS TO ACCOMMODATE FOR NEW OFFICES AND CONFERENCE ROOMS IN EXISTING BUILDING FOR TI. ADDITION OF ONE 1 1/4" LINE TO MATCH EXISTING SYSTEM LAYOUT. Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON ST P0 WAY CA 92064 858-513-4949 Owner: GATEWAY COLORADO PROPERTIES INC C/O ITNE PROPERTY TAX - DEPT 207 P 0 BOX 4900 SCOTTSDALE AZ Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 tqcci Worldwide i Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar"2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze ASI 60022 2701 LOKER AV WEST 290 FEBRUARY 2014 TFPI72 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON * 6 _____ 7/16 (11,1 mm) _______ I NOMINAL 2 : I MAKE-IN (50,8 mm) 2" __V (50,8 mm) 1-3/8' N______ (34,9 mm) WR 14 L i Fl 1/2' NPT** DEFLECTOR* CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F (570C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 IN- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8"(15,9 mm) FLUSH 3/8±5/16" (9,5±7,9 mm) MOUNTING 1/8"] 1 (3,2 mm) SURFACE CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) (7964) 1/2(12,7mm) &(3,,T2 8.m FLUSH MOUNTING SURFACE m) / CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2NPT) TY313 3 PURE WHITE (RAL9010)°° POLYESTER 371 5.6K PENDENT (1/2NPT) 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I ** Eastern Hemisphere sales only 135 135°F (57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200'F(93- ) 286 286°F (141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, PIN (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone i-1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. tqcci Fire Protection Products tqco Worldwide i Fire Protection Contacts www.tyco-fire.com Products Series EC-11 and I 11.2Kand 14.0K Extended Coverag General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occu- pancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installa- tion rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. Series EC-11 and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 C-14 Sprinklers. Upright and e Light and Corrosion-resistant coatings, where applicable, help extend the life of copper alloy sprinklers beyond that which occurs when exposed to corrosive atmospheres. Although corro- sion-resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, this testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE, Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. NOVEMBER 2014 - wLTr' t:J.i 11 Sprinkler Identification Numbers (SINs) T'5137 -Upright, ii!iil 1Y5237 - Pendent, 11.2K 1Y6137 - Upright, 14.0K TY6237 - Pendent, 14.01K TY5137 is a re-designation for C5137, G1894, and S2510. TY5237 is a re-designation for C5237, G1893, and S2511. TY6137 is a re-designation for C6137, G1896, and S2610. TY6237 is a re-designation for C6237, G1895, and S2611. TFP22O Pendent Ordinary Hazard AS1 60022 2701 LOKER AV WEST 290 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2" (12,7 mm) J NOMINAL MAKE-IN UPRIGHT CROSS PENDENT SECTION 16' nm TFP22O Page 2 of 8 WRENCH FLAT 3/4" ESCUTCHEON PLATE NPT** SEATING SURFACE Components: 1 1-Frame 2 - Button 3 - Sealing Assembly 2 4-Bulb 5 - Compression Screw 6 - Deflector 3 * Temperature rating is 4 indicated on Deflector. ** Pipe thread connections per 5 ISO 7-1 can be provided on special request. 6* FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) ASSEMBLY Technical Data Approvals TYCO Series EC-11 and EC-14 Extended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. Refer to Table A for complete sprinkler approval infor- mation including corrosion-resistant status. The approvals apply to the service conditions indicated in the Design Criteria section. Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are FM Approved. Refer to Table A for complete sprinkler approval information including corrosion-resis- tant status. The approvals apply to the service conditions indicated in the Design Criteria section. The Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 gpm/p5i1/2 (161,3 1pm/barl/2) K = 14.0 gpm/psi112 (201,6 1pm/bar112) Temperature Ratings Refer to Table A. Finish Sprinkler: Refer to Table A. Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical Characteristics Frame .......................Bronze Button.......................Bronze Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb ...................Glass (3 mm) Compression Screw............Bronze Deflector......................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applicable. Refer to Tables A, B, and C. TFP22O Page 3 of 8 Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural Brass I Chrome Plated I Polyester* Lead Coated Upright K=11.2 (TY5137) 135°F (57°C) Orange 1, 2, 3** 4 155°F (68°C) Red 175°F (79°C) Yellow Light Pendent Table B describes UL and C-UL K11.2 (TY5237) K=14.0 (TY6237) 1,2, 4 1, 2, 4 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent K=11.2 (TY5237) K14.0 (TY6237) With Style 30 Escutcheon 135°F (57°C) Orange 1,2,3,4 1, 2, 4 N/A Sensitivity Rating Table C describes FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Ordinary Table B describes UL and CUL Sensitivity Rating Table C describes FM Sensitivity Rating Upright K11.2 (TY5137) K=14.0 (TY6137) Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135°F (57°C) Orange 1, 2, 3, 4 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 1, 2,4 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent K11.2 (TY5237) K14.0 (TY6237) With Style 30 or 40 135°F (57°C) Orange 1,2, 4 N/A 155°F (68°C) Red 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green Notes (5). Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Cor- Listed by Underwriters Laboratories, Inc. (UL) rosion Resistant Sprinklers Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) * Frame and Deflector only. Approved by Factory Mutual Research Corporation (FM) ** Pendent Only Approved by the City of New York under MEA 17703.E N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - OR OR OR OR OR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR OR Style 40 Recessed - - - - - OR OR OR OR OR Upright or Pendent OR° OR° OR° OR° OR° SR SR SR SR SR 16 x 16 Style 30 Recessed OR° OR° OR* OR* OR° SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR* OR* OR° OR° OR° SR SR SR SR SR 18 x 18 Style 30 Recessed OR° OR° OR* OR° OR° SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR° OR* OR° SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed OR* OR° QR° SR* SR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable ° Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC- 11 OR EC- 14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) K-factor Style Response 11.2 EC Pendent or 14.0 EC Upright 11.2 EC Pendent 14.0 EC Recessed Style 30 Quick 11.2 EC Pendent or 14.0 EC Upright 11.2 EC Pendent 14.0 EC Recessed Style 30 11.2 EC Upright 14.0 [C K-factor Style Response 11.2 EC Upright 14.0 EC Pendentor Upright Quick 11.2 EC 14.0 EC Upright HC-1 Ceiling Type Noncombustible Unobstructed, Noncombustible Obstructed, or Combustible Unobstructed Noncombustible Unobstructed, Noncombustible Obstructed, or Combustible Unobstructed Combustible obstructed Combustible obstructed Noncombustible Unobstructed HC-2 Ceiling Type Noncombustible Unobstructed, Combustible Unobstructed TFP22O Page 4 of 8 Linear Spacing Area Spacing Ceiling Min Max Min 1 Max Height 10 20 100 1 400 Up to 30 10 20 100 400 Up to 30 10 20 100 400 Upto30 10 20 100 400 Upto30 Over 30 and 10 20 100 400 up to 45 Linear Spacing Area Spacing Ceiling Height Min Max Min Max 10 20 100 400 Up to 30 10 20 100 400 Up to 30 10 16 100 256 Over 30 and up to 45 HC-3 Linear Spacing Area Spacing Ceiling Ceiling Type K-Factor Style Response Min Max Min Max Height 10 16 100 256 Up to 30 11.2 EC Upright 10 20 100 400 Up to 30 Noncombustible Unobstructed, 14.0 EC Pendent or Combustible Unobstructed Upright Quick __________ __________ 10 16 100 256 Over 30 and 11.2 EC, up to 45 14.0 EC Upright NOTE The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0,8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi (1,2 bar). For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-li OR EC-14 SPRINKLERS (Note: Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-factor/area combinations) UL and C-UL Listing Requirements Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table D, based on main- taining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13; for example: Unobstructed, combustible or noncombustible, ceiling construc- tion with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combustible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattern Development". To prevent cold soldering, the minimum allowable spacing between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. TFP22O Page 50f8 Description Area Light Hazard 0.10 gpmlft2 Group I Ordinary Hazard 0.15 gpm/ft2 Group II Ordinary Hazard 0.20 gpm/ft2 gpm psi gpm psi gpm psi 14x14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5137 18 x 18 33 8.7 49 19.1 65 33.7 (K=11.2) Upright 20x20 40 12.8 60 28.7 80 51.0 14x14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5237 18x18 33 8.7 49 19.1 65 33.7 (K=11.2) Pendent 20x20 40 12.8 60 28.7 80 51.0 14x14 N/A N/A 39 7.8 51 13.3 16x16 N/A N/A 39 7.8 51 13.3 TY6137 18x18 N/A N/A 49 12.3 65 21.6 (K=14.0) Upright 20x20 N/A N/A 60 18.4 80 32.7 14 x 14 37 7.0 39 7.8 51 13.3 16x16 37 7.0 39 7.8 51 13.3 TY6237 18 x 18 37 7.0 49 12.3 65 21.6 (K=14.0) Pendent 20x20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 psi = 0.06895 bar 1 ft.2 =0.093 m2 1 gpm = 3.785 1pm 1 gpm/1t2 = 40.74 mm/mm TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-li AND EC-14 SPRINKLERS Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For example, obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: 1. Stems of the concrete tee construc- tion must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m). However, where the concrete tee length exceeds 32 feet (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. 2. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. FM Approval Requirements Series EC-11 and EC-14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with Factory Mutual requirements before proceeding with design. TFP22O Page 6 of 8 2-7/8 DIA. 1/2±1/8 (73,0 mm) - 1/2 (12,7 mm) (12,7±3,2 mm) 2-1/4 DIA. _ 1/4 (6,4 mm) FACE OF (57,2 mm) SPRINKLER L-. 1/8 FITTING )-. .4 (3,2 mm) MOUNTING SURFACE MOUNTING CLOSURE 7M PLATE 1-3/8 (34,9 mm) 1-1/8 (28,6 mm) FIGURE 2 SERIES EC- 11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8 DIA. 5/8±1/4 (73,0 mm) - 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4 (6,4 mm) FACE OF (57,2 mm) SPRINKLER ç 1/8" FITTING (3,2 mm) MOUNTING MOUNTING SURFACE ! PLATE CLOSURE 1-3/8(34,9mm) 7/8" (22,2 mm) FIGURE 3 SERIES EC- 11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITTING: 3/8' (9,5 mm) ABOVE TO 1/8" (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 1/2' (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT Installation Series EC-11 and EC-14 Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying MOUNTING 1/8 SURFACE - (3,2 mm) I CLOSU RE 3/4" NPT 25/16(587mm) -MOUNTING 1 - 13/16 (46,0 MM) PLATE a minimum-to-maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. "FITTING SIDE" TOWARDS SPRINKLER FITTING /\ WRENCH RECESS / (END 'A") FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS ij - tiL WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH applicable escutcheon) over the sprinkler pipe threads and with pipe- thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 2-7/8' DIA. (73,0 mm) 2-1/4' DIA. (57,2 mm) INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING FIGURE 4 SERIES EC-il AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON Step 2. After installing the Style 30, Step 3. For upright or pendent sprin- 40, or 60 mounting plate (or other klers wrench-tighten using only the TFP22O Page 7 of 8 PIN 51 - XXX -X -XXX F SIN SPRINKLER TEMPERATURE FINISH* RATING 893 11.2K PENDENT TY5237 1 NATURAL BRASS 135 135-F (57-C) 894 11.2K UPRIGHT TY5137 4 SIGNAL WHITE (RAL9003) 155 155°F (68°C) POLYESTER 895 14.0K PENDENT TY6237 5 JET BLACK (RAL9005) 175 175-F (79-C) POLYESTER 896 14.0K UPRIGHT TY6137 7 LEAD COATED 200 200°F (93°C) * Escutcheon ordered separately 9 CHROME-PLATED 286 286°F (141°C) 000 OPEN** ** OPEN indicates sprinkler assembly without glass bulb, button, and sealing assembly. TABLE E SERIES EC- 11 AND EC- 14 UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli- cable sprinkler wrench (Figure 5 and 6) to the sprinkler wrench flats (Figure 1). Care and Maintenance TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Frequent visual inspections are recom- mended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-li or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temper- ature rating, (specify) finish, P/N (from to Table E) Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) Flush Escutcheon, Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify*) *Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 TFP22O Page 8 of 8 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqca TEFLON is trademark of The DuPont Corporation. Fire Protection Products