HomeMy WebLinkAbout2711 LOKER AVE W; ; FA100079; PermitCity of Carlsbad Fire Alarm Permit Permit No: FAI 00079 2711 LOKER AV Job Address: WEST Permit Type: FALARM Parcel No: 2090814300 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 12/30/2010 Approved: 12/30/2010 Issued: 12/30/2010 Inspector: Project Title: IMAGINATION DESIGN MONITORING SYSTEM PLAN CHECK & INSPECTION Applicant: PROGRESSIVE TECHNOLOGY 759 W. 4TH AV ESCONDIDO, CA 800-577-2527 Owner: 2711 LOKER AVE LLC P0 BOX 2150 DEL MAR CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 IMAGINATION DESIGN STUDIOS 2711 LOKER AVENUE WEST CARLSBAD, CA. Fire Alarm Submittal 12-21-10 Submitted By; PROGRESSIVE TECHNOLOGY Security Systems, Inc. FILE COPY 759 WEST 4 AVE. ESCONDIDO, CA. 92025 License # 702990/Type C7/C10 IMAGINATION DESIGN STUDIOS Fire Alarm Submittal EguiDment List Description Model Manufacture CSFM# Fire Alarm Panel XR-5 DMP 7165-1157:104 Fire Alarm Annunciator 630F DMP 7165-1157:104 Smoke Detector 521B DMP 7272-1657:277 Manual Pull Station 850D DMP 7150-1157:112 Horn/Strobe 15CD P2R SYSTEM SENSOR 7125-1653:188 CONNECTION TO EXISTING WATERFLOW SWITCH CONNECTION TO EXISTING TAMPER SWITCHES Wire 18/4Cond. (Annunciator Cable) Wire 18/2Cond. (Initiation) Wire 14/2Cond. (Notification) 7 I SIGNALING USTED Economical, reliable performance for small commercial applications XRS commercial fire and slave communicators from DMP are perfect for small commercial installations that require reliable, cost-effective monitoring. Built-in 2-line dialer 500mA auxiliary power One Class A (Style D) zone for sprinkler supervision Four Class B (Style A) smoke-detector zones Four Class B (Style A) expansion zones Rely on DMP to increase the value of your next fire alarm installation. High-quality DMP panels and network monitoring technologies have led the industry for decades and significantly reduce the - cost of monitoring communications. S-9ZONE or 866 Notification Circuit-Modules . Fire Drill feature for practice evacuations 6OOcnAlarrnbeU output (XR5FC) . Swinger bypass option on all zones 500mA auxiliary output - - • Inherent power limited ciruit Opetaten16 VACr . . Automatic recall test repurtmg 4-wire lcepad and annuiidator circuit • C)ie.rnan Wali Test 6vnt hitoryan be vied from 630F keypad - .- a Automotfc standby battery test -- COMMUNICATION Each XR5 panel contains a built-in dual phone Line module with Line supervision that can communicate to one or two remote receivers using DMP Serial 1 digital dialer or Contact ID (CID) formats. You can also selectively enable alarm, supervisory/trouble, backup, and recall test reporting to either of the two receivers. NETWORK MONITORINGTM An iCCSL Network Alarm Communicator connects to the XR5 to provide Internet! LAN/WAN communications to the panel. When used in this manner or as a slave or stand-alone network communicator, the 1COMSL reduces or eliminates costly telephone lines and communicates to the central station via high-speed network connections. ONE-MAN WALK TEST Conduct one-man tests of the system and all connected devices using the Walk Test feature. Simply enter an access code into the keypad and XR5 panels automatically enter test mode. Each time a zone trips during the test, the bell rings for two seconds and a Sensor Reset is automatically performed to reset latched detectors. When the test is completed, the results display at the keypad and can be sent to the central station. 714 ZONE EXPANDER The 714 provides four inputs and is suitable for use with normally open and normally closed fire devices. 714 inputs are supervised and can be programmed for any zone type. The 714 connects to the keypad bus. 715 ZONE EXPANDER The 715 expander provides four Class B powered inputs and is suitable for use with the 2-wire conventional smoke detectors. 715 inputs are supervised and can be programmed for any zone type. The 715 connects to the keypad bus. POWERFUL FALSE ALARM REDUCTION FEATURES The built-in false alarm reduction features include cross zoning, fire verification, fire retard, and CleanMe reporting. Cross zoning allows multiple zones to be cross zoned and reports alarms only when two or more zones fault within a programmable time of 4 to 250 seconds. Should just one zone trip, only a zone fault report is sent to the central station. Fire verification provides a 120-second window during which a smoke detector can trip, be automatically reset, and then must trip a second time before an alarm is indicated. A single trip on the zone sends only a zone fault report to the central station. Fire retard allows a programmable time of up to 250 seconds for waterilow, detection. This eliminates the need for additional mechanical delays at the flowswitch. ANNUNCIATOR OUTPUTS Four open collector outputs can be used for a variety of remote control and annunciation applications. Each output is rated for 50m4 maximum. Add the Model 860 Relay Output module to provide four form C relay contacts. Each Model 305 relay is rated at 42mA and the module easily mounts inside the XR5 enclosure. TROUBLE ANNUNCIATOR MODULE For slave communicator applications, the XRSSL provides an enclosure door- mounted Model 377 Trouble Annunciator Module. The Model 377 offers Trouble and System OK LEDs with audible alert and a Silence button for acknowledging trouble conditions. BUILT-IN PROGRAMMER An internal English text Programmer enables technicians to easily program and test the panel from any keypad. A lockout code restricts access to only authorized persons. REMOTE PROGRAMMING Remotely program XR5 panels using Remote Linktm programming software from DMP. You can upload panel programming, make the necessary programming changes, and then download the revised programming into the panel. Expand Remote Link/System Link functionality with Advanced Reporting, Alarm Monitoring, Command Center, or Link Server packages. 630F FIRE COMMAND CENTER KEYPAD OPERATION For system annunciation, include the DMP 630F Fire Command keypad in your installation. This 20-key, 32-character LCD annunciator provides full-text displays of system events and menu prompts. It can be used for system operation, annunciation, and programming. The 630F is protected by either a keyswitch or code. The keyswitch enables the four function buttons: Silence, Reset, Test, and Fire Drill. Install the 630F using the included backbox and trim frame for flush-mount applications and the 635-R backbox for surface mount applications. The 630F has the ability to annunciate all on-board and expansion zones on the XR5. 692F FIRE COMMAND LED KEYPAD The 692F Fire Command LED Keypad offers 5 sets of highly visible LED annunciation of alarm and trouble conditions. It provides individual zone alarm and trouble LEDs for zones one to five only. Also, system LEDs, an internal sounder, 2-button Fire alarm initiation, and only Silence, Reset, and Fire Drill functions are provided. The 692F is used in applications where only the panels five on-board zones are used. w 0 E P1 ) 3fr flJ fl FourOpenCoectoritputs. Revivi 1) Use Model 060Hanese Model 309 out" 1Oxf 2 OulputHeaderJll a T%O Form C (SPD1) Ze2 Zaiie3 Zenel 3.tYtm a*anin 3.3kQen z1 For eup. We Ncenaly Open devices unvctbe usecL E rtx. IF, Model 377 Trouble Annunciator Module 0kect cOtoect to unoetched 120 VAC 60 Hz WadeI320 L 4rn4n transformer l5VAC4OVA I 1j I cernnct I I2VDC GROUND Cdd Vter Plee Eath Grouid Upto 5O0mAaueiycurreit at l2VDCtmtenrijall Keypad _____________________ Model 630P 63rnAat8.5Io14VDC I DDDD II .1221e; CDQ ®Slsedchcu6 L i: - L- .1r - rn ci ci cjcj ci ci cicicci -cicJcjci $ Zone LEO Keypads Keypad Model 6W 30mA atflb i& v. XR5FC System Configuration Diagram S L 14RECO1MAND KEYPADS -6_30F) Iéñiote Fire Command - 32-character LCD 635-R Keypad Conduit Backbox 692F Fire Command' Keypad AUXILIARY MODULES 377 Trouble Annunciator Module (included with XRSSL) 860 Relay Module 865 Style WIX Notification Circuit Module 866 Style W Notification Circuit Module C0M5L Network Alarm Communicator EXPANSION MODULES 714 4-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion POWER SUPPLIES 505-12 Provides 5 Amps® 12 VDC 505-121 Provides S Amps® 12 VDC 505-121X Provides 5 Amps® 12 VDC COMPUTER SOFTWARE Remote link Upload/Download Programming Software System Link End-User Management Software Advanced Reporting Module Alarm Monitoring Module Command Center Module Link Server Application DETECTORS SLR-835B Photoelectric Smoke 52IB/BXT Addressable Smoke, QeanMe ACCESSORIES 300 Plug-in Harness 305 Plug-in Relay Output 306 Harness Connection 318 Dual Battery Harness 320 40 VA Wire-in Transformer 367 12 VDC 77 Ah battery 370RJ Lightning Suppressor with Two RJ Jacks Primary Power 16.5 VAC 40V Secondary Power 12 VDC 7.7 Ah battery (Model Outputs Auxiliary 500mA (i 12 VDC Annunciator 50mA each switched ground) XR5FC Outputs Alarm 600mA012VDC Smoke 100mA@12VDC Enclosure Red (Wiels 340FC or 3405L) ) on imensis 12.5" x 9.5" x 3.75" Material 20-gauge cold-rolled steel LISTINGS AND APPROVALS 3 Refer to the XRS Installation Guide (LT-0229), XRS Programming Guide j (IT 0312) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshal (CSFM) FCC Part 15 ' FCC Part 68 Underwriters Laboratories (UL) Listed ANSI/UI. 864 Control Units for Fire-Protective Signaling Systems For additional information, access www.dmp.com and select Compliance. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 4m -1 - L_J S4AUNG (\ NYC MEA 1-— . UEft R re annunciation sagutions DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and commercial fire applications. The 630F provides 32-character full text LCD display of system events and menu prompts for efficient, easy use. The keypads offer simple, one-button access to common features, including: Silence alarms Reset sensors Test the system Perform a fire drill The 692F includes a highly visible LED annunciator, Attractive non-obtrusive designs Fotihort tones indicate an unsuccessfut keypad operation 2-button Panic keys • Quick key on keypad for changing user code MdIbte1one on each key press 0,10f FJEAUMM -Zo,iè W: Normal, Trouble, a 2-charcter LCOdisp[ay Byp;~s~dl and Alarm condthons Flush or Surface mount l(yswitdi ehabtes single button operation Full operation with authorized code Built-in dianostks . . - . ACPowe Thub1e Alarm 1El) •--• - - -5-- -- -- -. - . -.- Cçmpatibte With XR5F6XR5SL XR100IXR500 Series, or . .. XR25WF t_; —0a System events display in,plal n, Erviish _______------ 030F REMOTE ANNUNCIATOR SUPERVISED AND STATUS LED$ The 630F Fire Command Center offers UNSUPERVISED OPERATION The Green Power LED tights when primary a 32-character full text LCD readout that The 6301 keypad can be programmed AC or DC power to the panel is at an displays system events and menu prompts, for supervised or unsupervised operation acceptable level and flashes when its making it efficient and easy-to-use. The on the keypad data bus, increasing the battery is low or missing. backbox and trim frame provide an attractive overall number of keypads you can install AYellowTroubte LED turns on when either installation. The keypad can either be flush- to provide maximum flexibility. When the panel has failed to communicate mounted or surface-mounted. supervised, the keypad occupies its own with the central station receiver or when address. Unsupervised operation allows phone line 1 or 2 is in a bad condition. - :"---: - — you to install multiple keypads on the bus The 6921 also uses a Yellow Silenced LED . with the same address. The 692F is always to indicate when the panel Bell Output I set as unsupervised, has been silenced. p... 692F FIRE COMMAND KEYPAD ZONE LEDs The 6921 Fire Command Keypad offers Zone LEDs indicate the status of the first highly visible LED annunciation of alarm five zones Each zone has a trouble and and trouble conditions on DMP XR5FC alarm LED to indicate at-a-glance zone and XRSSL Commercial Fire Panels. status. 630F Keypad It provides individual zone alarm and trouble LEDs, status LEDs, an internal KEYPAD FUNCTION KEYS buzzer, 2-button functions. There are four clearly labeled function SINGLE-BUTTON OPERATION The 692F is cased in a durable Red plastic keys on the 6921 keypad. The SILENCE, RESET, TEST, and CODE function keys The 630F Fire Command Center has a factory housing with a removable base for easy allow the user to press one key to initiate installed kevswitch that enables the four installation. .' ,... • function buttons-Alarm Silence, System Reset, System Test, and Fire Drill. The user can also access these four functions and many more through the User Menu by entering a valid user code. BUILT-IN DIAGNOSTICS An internal diagnostics program lets installers and service technicians test the operation of the keypad at any time without disabling the system. upci auuII. ia au auuvu v'..u, n.y measure, C, the user must enter a valid security code after pressing one of the function keys. 692F Keypad Fire Command Zones Display Panic ompitibler panoas Keyboard Red in User operating Operating Current Model Type Keys - Alarm Bnghtness Voltage Standby -Alarm. (610—F None LCD 5FCIXR5S1, XR100IXR500 Series, No Yes 12 VDC 63A 92mj -- XR250OF --- — 692F None LED Yes XR5FC/XR5SL (First five zones only) No Yes 12 VDC 30rnA 70mA A;O-1 KEYPAD ACCESSORIES Operating Voltage 8.5 to 15 VDC 635 1.75" 630F Keypad Conduit Backbox Current Draw 63mA standby, 92mA maximum 1 635F 25" 630F Keypad Conduit Backbox i Trim Frame Dimensions 10.4" W x 7.0" H x 1.7" 0 695 1.5" Keypad Conduit Backbox Backbox Dimensions 8./5"Wx6.175"Hx2.5" [) 696 1/2" Keypad Backbox Panel Compatibility XRSOO Series, XRI00 Series, 699 Keypad Deskstand XR2500F 300 4-wire Replacement Harness LED Keypad Housing Operating Voltage 8.5 to 15 VDC LISTINGS AND APPROVALS Current Draw 3OmA standby, 70m4 maximum California State Fire Marshal (CSFM) I Dimensions .8" W x 5.0" H x 1.1" 0 FCC Part 15 Panel Compatibility XR5FC and XR55L Underwriters Laboratories (UL) Listed ANSI/UI 864 Control Units for Fire Protective Signaling ANSI/UI 985 Household Fire Warning 1 For additional information, access wwvsdmp.com and select Compliance ---. '-,- -..-.-- . Now, 2500 North Partnership Boulevard * DialM.nItnnPdw*.. Springfield, Missouri 65803-8877 num X-016111111=1 lots Secondary Power Supply 6.1 Battery Terminals 3 and 4 Connect the black battery lead to terminal 4 on the panel and then to the negative terminal of the battery. The negative terminal connects to the enclosure ground internally through the XR5FC and XR5SL panel circuit board. Connect the red battery lead to terminal 3 on the panel and then to the positive terminal of the battery. Observe polarity when connecting the battery. rJh4FXR5FC. and XR5SL panels are capable of recharging two 7.7 Ah batteries (15.4 Amp/hours) within 24 hours. Do not use battery backup with 24 VDC input: Do not connect batteries to the XR5FC and XR5SL panels when powering the panels with 20 to 28.2 VDC voltage from a Fire Alarm Control Panel (FACP). The XR5FC and XR5SL panels use the backup battery capability of the FACP for their standby requirements. 1 Use sealed lead-acid batteries only: Use the DMP Model 367, 12 VDC 7.7 Ah or Model 369 7.0 Ah sealed lead-acid rechargeable battery. Batteries supplied by DMP have been tested to ensure proper charging with Y DMP products. DO NOT USE GEL CELL BATTERIES WiTH THE XR5FC AND XR5SL 6.2 Earth Ground (GND) Terminal 4 of the XR5FC and XR5SL panels must be connected to earth ground using 14 gauge or larger wire to provide proper transient suppression. DMP recommends connecting to a metal cold water pipe or ground rod only. Do not connect to electrical conduit or a telephone company ground. 6.3 Battery Replacement Period DMP recommends replacing the battery every 3 to 5 years under normal use. 6.4 Discharge/ Recharge The battery charging circuit on the XR5FC and XR5SL panels float charge at 13.9 VDC at a maximum current of 1.2 Amps using the Model 320 Transformer. The total current available is reduced by the combined auxiliary current draw from terminals 6, 7, 15, 17, 19, and 21. The various battery voltage levels are listed below: Battery Trouble: Below 11.9 VDC Battery Restored: Above 12.6 VDC 6.5 Battery Supervision The XR5FC and XR5SL panels load test the battery once every three minutes when AC power is present on terminal 1 and 2. The test lasts for five seconds. If, during the test, the battery voltage falls below 11.9 VDC a low battery is indicated. The test is then repeated every two minutes until the battery charges above 12.6 VDC, the battery restored voltage. If the low battery does not recharge and is replaced with a fully charged battery, the charged battery will not be detected until the next two minute test is done. If AC power fails during normal system operation, a low battery is indicated any time the battery voltage falls below 11.9 VDC. Digital Monitoring Products XR5 Installation Guide 8 lots 6.6 XR5FC and XR5SL Power Requirements During AC power failure, the XR5FC and XR5SL panels, and all auxiliary devices connected to the panels, draw their power from the battery. All devices must be taken into consideration when calculating the battery standby capacity. Below is a list of the power requirements of the XR5FC and XR5SL panels. Add the additional current draw of DMP keypads, smoke detectors, and any other auxiliary devices used in the system for the total current required. 6.7 XR5FC and XR5SL Standby Battery Calculations Standby Battery Power Cakulatlons Standby Current Alarm Current XR5FC/XR5SL Panel ' Qty --L —x 'SOmA mA Qty _1_ 50mA MA Relay Outputs 1-2 (ON) Qty ______x 30mA Qty ______x 30mA Active Zone 1 3.3mA 3.3mA Active Zones 2-5 Qty _____x 4mA Qty _____x 4mA 521B/Bcr Smoke Detectors Qtyx 0.076mA) Qtyx cpo7oiiA' SLR-835B Smoke Detectors Qty _____x 0.07OmA Qty ______x 0.070mA Other 2-Wire Smoke Detectors Qty _____x 0.1mA Qty x O.1mA Bell Output (600mA Max.) __mA 377 Trouble Annunciator Mxiui 17mA 17mA 630FRemote Fire Command center Qty x ç63niA Qty - 92niA 692F Fire Security—Command Keypad _x 3(Jm.A Qty - 7OriiA 714 Zone Expansion Module Qty - x 7mA Qty _____x 7mA Active Zones (EOL Installed) Qty _____x 1.6mA Qty _____x 715 Zone Expansion Moduk Qty 7inA Qty :'mA Active Zonec (FOI It ilkd)Qty liu/\ - Qt x Smoke Alarms Qty x .1 mA ...: Qty. .1mA 865 Style W or x Notification Module Qty _x 26mA Qty X 85rnA 866 Style W Notification Module Iy x rN 76mA Aux. Powered Devices on Terminals 7 and 6 mA mA Other than Keypads Total Standby mA Total Alarm ______mA Total Standby mA x number of Standby Hours needed = mA-hours Total Alarm mA mA-hours + mA-hours *Based on 10% of active zones in alarm Total X 0.0001 = Amp-hrs Required XR5 Installation Guide Digital Monitoring Products CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0104 Page 1 of 1 CATEGORY: 7165— FIFE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: çDigftalMoñiting Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: VMödel XRSFCand XR5SL fire alarm control units. Automatic, manual, noncoded, local, rethôte s1ation,.centraI station, waterfiow and sprinkler supervisory service. Model XR5SL does not employ a bell output circuit or 4-wire detector power, it is used for slave applications deriving its power from the host (master) control unit Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XRSFC, XR5SL; Control Panels 630F*, 692F; Keypad 865,866; Bell Module 320; Power Transformer 377; Trouble Indicator Module *714 V15; Zone Expanders RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. The control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Alarm Verification Feature, the maximum RetardlResetlRestart (including smoke detector reset time) shall not exceed 30 seconds. *Rev. 02-19-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ,\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an IJT endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 1117 low iww. - Class B (Style A) Fire Zones 11.1 Description Terminals 15 to 22 are the Class B (Style A) fire zones on the XR5FC and XR5SL panels. These zones are suitable for connecting powered or non-powered fire devices. For programming purposes, these zones are designated 2 to 5. The maximum line impedance is 100 Ohms. The zone configurations on terminals 15 to 22 are described below: Terminal Function Terminal Function 15 Zone 2 voltage sensing 16 Zone 2 negative 17 Zone 3 voltage sensing 18 Zone 3 negative 19 Zone 4 voltage sensing 20 Zone 4 negative 21 Zone 5 voltage sensing 22 Zone 5 negative 11.2 Operational Parameters The Class B (Style A) zones on the XR5FC and XR5SL panels can detect three conditions: open, normal, and short. Each zone terminates with a Model 309, 3.3k Ohm EOL resistor (provided with the panel) and is rated for 53mAat 12 VDC. The compatibility identifier for use with 2-wire smoke detectors is: A. 11.3 Zone Response Time A condition must be present on the zone for at least 500 milliseconds before it is detected by XR5FC and XR5SL panels. Only use detection devices that are rated for use with this delay. 11.4 COiflhiätiblë2Wire Smoke Detectors The table below lists detectors meeting the compatibility requirements for use with the Class B (Style A) zones on the XR5FC and XR5SL fire panels. Do not mix detectors from different manufacturers on the same zone. Manufacturer - Detectai Base Base ID #of Detectors Detection Systems DS250 B M132W A 10 Detection Systems DS250Th, DS250HD B MB2W, MB2WL A 10 Detection Systems D5282, DS282Th B 10 Hochiki SLK-12 HD-4 HSB-12-1, HSB-12-1N HB-80 20 DMP/Hochiki SLK-835, SLK-835H HD-5 HSB-200, HSB-200N HB-55 7 DMP/Hochiki SLR-835 HD-3 NS6-100 HB-55 7 DMP/Hochiki SLR-835B HD-6 7 Sentrol/ESL 429AT, 5216 S21BXT ISO9A? 12 System Sensor 1100, 1400 STD 10 System Sensor 1151 STD B110LP 10 System Sensor 1451, 2451Th STD B401, B401B 10 System Sensor 1451DH STh DH400 10 System Sensor 2100, 2100T STD 10 System Sensor 2400, 2400AT, 2400A11 _2400Th STD _____ 10 System Sensor 2451 STD 5401, 84018, DH400 10 5instpUation Guide Digital Monithring Products Security Smoke Detection Overview GE brand 500 Series two- and four-wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounders in two- and four-wire applications, specifically to meet residential code requirements. The 500 Series also offers choices for optional auxiliary relays and isolated heat sensors, not available before in the 500 Series. GE is also proud to offer proven technology like CleanMe®, dust compensation, field replaceable optical chambers, and self-diag- nostics. CleanMe® is only available on the 500 2-wire models and will communicate to the GE FireworX panels when servicing is required. 500 Series detectors work on a light-scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high- speed photo diode as the sensing element. This design has superior protection against nuisance alarms caused by dust, insects, RF interference, and ambient light. The proprietary optical chamber is field replaceable. In the event of a confirmed alarm the LED will light continuously. The unit indicates trouble by flashing the LED every second. This meets the NFPA 72 field sensitivity testing requirements. Units with built-in 85dBA sounders emit a temporal 3-3-3 tone pattern when in alarm and will emit a steady tone when the input power is reversed. All wiring terminates in clamp-type screw termi- nals. The detectors mount to a standard single-gang electrical box, a four-inch octagonal, four-inch square electrical box, or WIREMOLD No. 5739 fixture box. Standard Features Remote maintenance (CleonHe®) reporting (2-wire models) and built-in drift compensation reduces false alarms Self diagnostics eliminates the need for external meters Field-replaceable optical chamber makes service fast and simple Small, low profile design blends with any environment Optional auxiliary functions include: Integral sounder Fixed/Rate-of-Rise heats Auxiliary relay Single station smoke with system heat Built-in power supervision relay Sinr%loke Detectut-%rs * . I A WIM AUXiliary Functi*n-s Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 1 of 2 ApIication 500 Series detectors are ideal for both retrofit applications and new installations alike. They are particularly well-suited for installations where detector reliability is essential, but where analog devices may not be appropriate or feasible. With their replaceable optical cham- bers, these detectors are equally well-suited to dusty environments where detectors require frequent cleaning. Assembly Optional fixed temperature sensor Diagnostic LED / .. Optional rate-of-rise sensor Mounting and Installation Dimensions Photoelectric sensor Replaceable optical chamber Detector cop SOON detector bases mount directly to standard single-gong electri- cal boxes, three-inch round, or four-inch octagonal boxes. Detector heads simply twist onto the base. Heads are equipped with a break- away locking tab, which prevents unauthorized removal. Terminals L- (san El I i accept 12 to 24AWC field wiring. U Typical Wiring 2-wire Initiating + Cl(QJlt Listed Alarm Control - -+ First Detector EOL Device -+ Last Detector di ip F(91 ro Specifications Eiectrital Power Supply 8.5-33VDC (12/24 V operation) polarity sensitive Maximum ripple pk-pk 16/12/24 VI 10% (Vpk-pkl Typical overage standby current 70 pA Typical alarm current (6/12/24V) up to 60 mA max if not limited by control panel Auxiliary relay contacts 1.0 A @30 VDC: Form c Alarm contacts 500 mA @36 VDC (resistive) Photoelectric sensitivity 3.1% + 0.5 - 1.0% Color White Field wiring size 12-24 AWG (16-22 recommended) Detector packaging 10 detectors per carton Heat detector specifications Rate-of-Rise: 15° F/min and >105° F (8.3° C/min and >40.6°C) Fixed Threshold: 135° F (57.2°C) UL 2-wire compatibility S10A. S11A identifiers Drift compensation adjustment 1.0% ft. max Detector head dimensions 5.5 D 2° H (14.0 x 5cm) Mounting dimensions 5.25 (13.3 cm) diameter: Operating temperature 32° to 100°F 10° to 37° C) 0.3"(0.8 cm) height Operating humidity range 0 to 95% non-condensing RFI immunity 20 V/m mm: 0-1000 MHz Reset time 1 second mm ................... .................................... . ............. .............. Listings C-UL-US, CSFM, MEA - - Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 2 of 2 Ordering information Model ,ptrot AfawQirrent tm/tI everse - wire photoelectnc. 6-33VDC 7S1OAS min. 60max 521BXT 2wire, photoelectric, 6-33VDC, fixed temp and rate-of-rise heat 509A/S10A 5 mm. -60 max. 521NCRXT 2-wire, photoelectric. 8.5-33VDC, fixed temp and rate-of-rise heat, aux. relay S11A 15 mm. -60 max. S21NCSXT 2-wire, photoelectric, a5-33V0C. fixed temp and rate-of-rise heat, temporal 3 S10A 10 mm. -60 max 10 sounder 521NCSRXT 2-wire, photoelectric, 8.5-33V0C, fixed temp and rate-of-rise heat, aux. relay S11A 15 mm. -60 max 10 temporal 3 sounder 541C 4-wire, photoelectric. 6-33VDC N/A 20 5410<1 4-wire, photoelectric, 6-33VDC, fixed temp and rate-of-rise heat N/A 20 541N -- 4-wire, photoelectric. 8.5-33V0C, fixed temp and rate-of-rise heat. aux. relay. N/A 35 13 temporal 3 sounder 541NCSXTE 4-wire, photoelectric. 8.5-33VDC, fixed temp and rate-of-rise heat, built-in end N/A 45 28 of line relay, temporal 3 sounder 541NCSRH 4-wire, photoelectric. 8.5-33V0C, isolated fixed temp and rate-of-rise beat. aux. N/A 35 13 3 sounder, non-latching LED with auto reset 541NCRXT 4-wire, photoelectric. 8.5-33V0C, fixed temp and rate-of-rise heat, aux. 25 541F'JCXTE 4-wire, photoelectric. 8.5-33VDC, fixed temp rote-of-rise heat, built-in end N/A 35 of line relay 541NCSXT 4-wire, photoelectric. 85-33VDC. fixed temp and rate-of-rise heat, temporal 3 N/A 30 13 sounder 548C 4-wire, photoelectric, 8.5-33V0C. IJLC Listed 548Cr 4-wire, photoelectric, heat. 8.5-33VDC. ULC Listed Note: Only 500 Series 2-wire smoke detectors are CleonMe compatible. Opodd the foil gsqffi~tes as pi'it*1 8 6-33V0C operation C 8.5-33VDC operation E End-of-Line relay H Isolated rate-of-rise and fixed temp sensors R Auxiliary relay S 85dBa sounder Xl Rate-of-rise and fixed temo sensors Arctsortes ---,--*-----------"--*---*---,-- - 405-05 Polarity reversal module enables sounder interconnection of all 4-wire smoke detectors, when initiating detector sounds all smokes sound. 401 Test magnet in a plastic shell for pole mounting SM200-12PKG Smoke in a Can!- canned smoke for functional testina SM-extlL Smoke inc Conl5 extension tube 211-10P KG Replacement optical chambers (set of 101 500PLT-SPKG 6 trim ring for wider coverage area Data Sheet FX85001-0606 Issue 1 Nat to be used for installation purposes. Page 3 of 2 Security U.S. T 888-GESECURITY F 503-691-7566 Canada T 519 376 2430 F 519 376 7258 Asia 1852 2907 810$ F 852 2 142 5063 Latin America 13055934301 F 305 593 4300 w.gesecurity.comJfireworx © 2009 General Electric Company All Rights Reserved imagination at work CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. ç7272-1657:027r) Page 1 of 1 CATEGORY: 7272 - PHOTOELECTRIC SMOKE DETECTOR USTEE: tEDWARDSTA'Division of UTC Fire & Security Americas Corporation, Inc.8985 Town 'Center Parkway, Brandenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 309-8123 Email: rhonda.micochem@ge.com DESIGN: çModel521131511c*, 5IIAFT*, 521BXT, 52ICRXT (2-wire)and 541C, 541CXT, 541AXT (4-wiFe) photoelectric type smoke detectors. Model 521 BXT, 521 CRXT, 541 CXI, 511 AFT*, and 54IAXT smoke detectors employ a supplemental heat sensor to assist the smoke detector in lire situation. This heat sensor is not a heat detector and is not intended for use in lieu of the required heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6.5 -33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed electrically compatible lire alarm control units. NOTE: Formerly: 7300-0447:140 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ,\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational 'v requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires 2011) Authorized By: FRANCIS MA rEQ. Program Coordinator Fire Engineering Division ,' I. L t -: I&j (t4 LISTED provides Simple operation alarm The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-pLated contacts to avoid the risk of corrosion SHE mnms asc J1L S Tfl3Ø DESCRIPTION MOUNTING OPTIONS 8500 OPERATION The DMP 850 Series Fire Alarm Pull A variety of mounting options are On the Model 850D Dual Action Pull Station is a high quality, die-cast available for the 850 series. It can be Station, the push bar rotates inward metal manual pull station available flush mounted to a standard single gang allowing the PULL handle to be grasped in either single-action or dual-action switch box or surface mounted in two in a one handed motion. configurations with SPST contacts and optional configurations. The Model terminal strip connections. The normally 850-SB Interior Surface Backbox or the ADDRESSABLE ZONE open contact, which closes when the pull Model 850-WP Weatherproof Backbox To create an addressable reporting zone station is activated, is rated for 1 Amp® both allow conduit connection to the for the 850 Series, Install a Model 711 30 VDC. The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module. avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. 8505 OPERATION The Model 8505 Single Action Pull Station is operated by putting the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. PULL Screw Terminals To next To Are Alarm - - device or Control Panel - --------- L__ - EOL resistor Model 850 Wiring Diagram ORDERING INFORMATION 8505 , Single-action pull station 5_506. çDualactionpull station 850-SB - Interior surface sheetmetat backbox 850-WP Weatherproof surface die-cast backbox 850-AR Scored acrylic breakrods (1 dozen) 8505/711 Single-action pull station w/addressable module 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. ç 7150-1157:0112 Page 1 of 1 CATEGORY: 7150 FIRE ALARM PULL BOXES LISTEE: l5gitai Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Mod 850D (key lock, push bar) and 8508 (key lock, no push bar) noncoded manual pull stations. Suitable for outdoor use when installed with Model 850-WP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Rev 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. The listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June3(2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division *1 SYSTEM ~4, SENSOR Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlerrAdvance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. "4.. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units 15,15R5, 30,75,95,110,115,135,150,177, and 185 Horn rated at 88+ d8A at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAtert Advance series offers the most versatile and easy-to-use line of horns,strooes, and horn strobes in the industry. With white and red plastic hosirgs, wall and ceiling mounting options, and plain and RRE-printed devices, SpectrAlert Advance can meet virtually any applicoticrri recuirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a \ariety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with rninLma intrusion into the back box, which make installEtions fast and foolproof while virtually eliminating costly and time-corsum ng ground faults. Furthermore, a universal mounting plate with an cnboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, held-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of app s:ation requirements. Agency Listings SIGNALING WED APPROVED 5401 (thlrnes,hom srnobns,honns) 3023572 555 2(020685) 0 MEA approved 7125-1653:186 (Indoorntrobes( 7125-1653:188 (horn strobes, MEA452-05-E ohlnnestnobes( 7135-1653:189 (horns, thinner) Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to standard 4 x 4x 1½-inch back box ,4-inch octagon back box, or double-gang back bnc Two-wire products shall also mount to a single-gang 2 x 4x 1718-Inch back box A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate Also, SpectrAJert Advance products, when used with the Sync-Circuit" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9and 175 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30 75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products the strobe shall be powered independently of the sounderThe horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDI listed to 01464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4'Vi6x 4111sx 2'/a-inch back boxlhe module shall also control two StyleY (class B) circuits crone Style Z (class A) circuit The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications "7' Standard Operating Temperature 32°f to 120°f (0°C to 49°C) Humidity Range 10 to 93% non-condensIng Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DCJFWRor regulated 24 DC,FWRr Operating Voltage Range' 8 to 17.5V02Vnominali or 16 to 33V (24V nominal) Input Terminal Wire Gauge 12 to 18 AM Ceiling-Mount Dimensions (including lens) 68diameterx 25-high (173 mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 5.61x 4.TWx 2.5D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6-Lx4TWx 13-D (142 mm, Lx 119 mmWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9L x 50Wx 2.2-1) (151 mmlx 128 mm W 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 22Th1gh (180 mm diameter x 57 mm high) Wall-MountTrim Ring Dimensions (sold as a 5 pack) (TR-HS,TRW-HS) 5.TL x 4.8Wx 035D (145 mm Lx 122 mm W 9 m D) Ceiling-Mount Trim Ring Dimensions (sold as a pack) (1RC41S,TRCW-HS) 6.9diameter x 035high (175 mm diameter x 9 m high) Notes: 1. Full Wave Rectified (FWFO voltage Is non-regulated, time-varying power source that is used on some power supply and panel outputs. 2.P S, K, and SC products will operate at 12V nominal only for 15 and 15/75d A05-0395'OO7 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 8-173 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 177 -- _-185-------NA----_. NA NA NA 281 251 286 258 UL Max. Current Diaw (mA DClnput_. - RMS), 2-Wite Horn (817.5 Volts 15 Strobe, 15/75 Standard Candela 16-33 Volts 15 Range 15175 [15-115 cd) 30 75 95 110 115 temporal High r137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Curren t Draw (mA DClnput 132 RMS), 2-Wire Horn 16-33 Volts 135 150 154 Strobe, 177 High 80 Candela 185 90 Range 105 (135-185 cd) FWRlnput 161 184 16-33 Volts 135 350 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern d8 8-175 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechok DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 Settings 7,8, and 9 are not available on 2-wire horn strobe 0S-O395-7 SpectrAlert Advance Dimensions Wall-mount horn strobes Ceiling-mount horn strobes Wail back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes ç P2R 2-Wire Horn Strobe, Standard cd*, Red P2RH* 2-Wire Horn Strobe, High cd, Red P2W* 2-Wire Horn Strobe, Standard cd, White P2WH* 2-Wire Horn Strobe, High cd, White P4R 4-Wire Horn Strobe, Standard cd, Red P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wail Strobes SR Strobe, Standard cd, Red SRH Strobe, High cd, Red SW Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn Strobes PC211# 2-Wire Horn Strobe, Standard cd, Red PC2HH 2-Wire Horn Strobe, High cd, Red PQ\(sI 2-Wire Horn Strobe, Standard cd, White PC2WW 2-Wire Horn Strobe, High cd,White PC411 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW' Strobe, Standard cd, White SOM-1 Strobe,High ccL White Horns HR Horn, Red HW Horn, WMe Accessories BBS-2 Back Box Skirt, Wail, Red BBSW-2 Back Box Skirt, Wail, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White I RC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceding, White Notes: Add'-P'to model number for plain housing (noFIRE'marking on cover), e.g., P2R-R t Add -SP'to model number for'FUEGO'marking on cover, e.g. 1`211-SP. j'Standard Cd' refers to strobes that include 15, 15/75, 30,75,95, 110, and 115 candela settings. Hi cd'refers to strobes that include 135,15Q 177, and 185 candela settings. " 5YTEII4 3825 Ohio Avenue. St Charles, 1160174 tOcttodew* nOtke ten#ensomx SENSOR Phone: 800-SENSOR2 . Fax 630-377-6495 O5-0395er7.4/O9. #2132 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. c-7125.-1653:0188 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: cStéñi Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave,, St Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. VModels P-2R;P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R,' PC2W PC2RH and PC2W1-I Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix °K indicating indoor or outdoor use, or may be followed by suffix °P° for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA\BW (Wall), SA-WBBC (Ceiling) and (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDCIFWR Hi CD Horn/Strobes 16-33 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible lire alarm control units. Suitable for indoor or outdoor use, ceiling or well mount The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an L endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires Iie.-3O2O1t Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division