HomeMy WebLinkAbout2712 LOKER AVE W; ; FA060012; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA060012 2712 LOKERAV Job Address: WEST Permit Type: FALARM Parcel No: 2090810100 Lot #: 0 Status: ISSUED Applied 4/11/2006 Approved: 4/11/2006 Reference No.: Issued: 4/11/2006 PC #: Inspector: Project Title: STAPLES TWO (2) FIRE ALARM INSPECTIONS Applicant: Owner: JJJ ENTERPRISES FRANZ-LOKER L L C 533 S VINEWOOD ST 2710 LOKER AVE W ESCONDIDO CA CARLSBAD CA 760-747-3050 Fees ($) Add'I Fees ($) Total ($) Balance ($) 120 0 120 0 ft f=Ao(o oo ig., FIRE ALARM - SECURITY LOW VOLTAGE SYSTEMS LOKER BUSINESS CENTER PHASE I (STAPLES) PALOMAR OAKS NORTH INDUSTRIAL CARLSBAD, CA. FIRE ALARM SYSTEM -00 APPROVED 4c) 4(7/06 ,APPROVED AS NOTED J NOT APPROVED, RESUBMIT CHECKING IS ONLY FOR COFORMANt VTH THE DES!GN CONCEPT of THE PROJECT D CUtPLIANCE WITH THE INFORMATION GIVEN iN THE CONTRACT DOCUMEIS. CONTRACTOR IS RESPONSIBLE FOR 3ENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOB SITE AND FOR COORDINATION OF THE WORK OF ALL TRAO LOKER BUSINESS CENTER PHASE I (STAPLES) PALOMAR OAKS NORTH INDUSTRIAL. CARLSBAD, CALIFORNIA BILL OF MATERIALS NOTIFIER NFW-I00 FIRE ALARM PANEL CSFM# 7165-0028:235 NOTIFIER FDU-80 ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER NP-100 PHOTO SMOKE DETECTOR CSFM# 7272-0028:231 NOTIFIER NOT-BGI2LX ADDRESSABLE PULL STATION CSFM# 7150-0028:199 NOTIFIER NMM-I00P ADDRESSABLE MINI MODULE CSFM# 7300-0028:230 WHEELOCK RSS SERIES STROBES CSFM# 7125-0785:141 WHEELOCK AS SERIES STROBES CSFM# 7125-0785:131 NOTIFIER FCPS 24S6 POWER SUPPLY CSFM# 7165-0028:235 ©NOTIFIER® by Honeywell GENERAL The NOTIFIER FireWarden-100 (NFW-100) is a compact, cost-effective, intelligent addressable fire alarm control panel with a capacity of 198 addressable NOTIFIER de- vices on one Signaling Line Circuit (SLC) and a built-in modem for remote site upload/download or remote moni- toring. The Signaling Line Circuit (SLC) loop supports up to 99 addressable detectors including photoelectric, photoelec- tric with heat, ionization, photoelectric duct, fixed heat, and fixed heat with rate-of-rise detectors. It also supports up to 99 addressable modules including monitor (two-wire detector, normally open devices), conventional two-wire smoke monitor (supervise compatible two-wire smoke de- tectors), and relay (two Form-C) modules. The panel uses surface-mount technology and is designed for ease of in- stallation, programming, and maintenance. It features the latest in advanced fire protection technology, including maintenance alert and automatic detector test functions. SPECIAL FEATURES: Built-in modem. Selectable strobe synchronization per NAC. Remote site upload/download. Four Class B or two Class A NAC circuits. FEATURES SLC Loop: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices (99 de- tectors and 99 monitor, control, or relay modules), in- cluding addressable smoke detectors, heat detectors, and duct detector. SLC loop maximum length 10,000 ft. (3,048 m) © 12 AWG (3.1 mm2). Requires twisted, shielded wire (3,000 ft./914.4 m untwisted, unshielded wire). Notification AppIiance Circuits (NACs): Four onboard NACs with additional NAC capability us- ing output control modules (NC-lao). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 5.0 amps total NAC power with XRM-24. Advanced Fire Technology: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. Programming and Software: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 key- board or PC via VFWARDEN-CD Windows® utility. August 11, 2005 DN-7005 .A1-100 FireWarden-1 00 Intelligent Addressable FACP (NFW-100) with Built-In Modem Section: Addressable ,'•'\ IVI EA $_t California 341O3-E t:hate } Vol. III 1e 7165-0028:235 LISTED S635 < > APPROVED Remote site upload/download capability. Two-level user-programmable passwords. Custom English labels (per point) may be manually en- tered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. User Interface: Built-in modem (DACT). Remote Acknowledge, Silence, Reset and Drill via ad- dressable monitor modules, ACS Series annunciators or FDU-80 remote annunciator. ElA-232 printer/PC interface (variable rate) on main cir- cuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight say- Ings adjustments. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS Series annunciators. EIA-485 supporting up to 32 FDU-80 annunciators. Maintenance alert warns when smoke detector dust ac- cumulation is excessive. Automatic device type-code verification. cont'd pg. 3 14 a This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. H For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 E4 r : dl 1=1.1 N OTI Fl E R ENCINEEIING & MANUFACiIJRING MadeintheU.5.A. by Honeywell 12 Clintonville Road, Northiord, Connecticut 06472 QUALITY SYSTEMS DN-7005 • 08/11/05 - Page 1 of 4 —00.L__ SMOKE DETECTORS NP-100, NP-100T, NI-100 HEAT DETECTORS NH-100, NH-100R DUCT DETECTOR ND-100, ND-100R 1 1 00 00 0 MONITOR! CONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-100R 'Pr MINI MONITOR NMM-100P Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTM) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES - EIA -485 INTERFACE 24 VDC (DIM-485) built into the motherboard Pll~ (four wires) FDU-80 Up to 6,000 ft. (1825;8 m) between each FDU-80 in the EIA485 loop, and between each FDU-80 and the FACP 24 VDC .1 l EIA -485 • in ACS mode (two wires) ANNUNCIATORS AFM-LED, LDM, ACS/ACM EIA -232 INTERFACE (PIM-24) built into the motherboard 4I PRINTER NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. Fire Warden-100 Fire Alarm Control! Communicator WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit operation. It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Requirements Distance in Feet (m) Typical Wire Size Twisted-pair, shielded 10,000 feet 12 AWG (3.1 mm2): Belden 9583, Genesis 4410, (3,048 m) Signal 98230, WPW D999. Twisted-pair, shielded 8,000 feet 14 AWG (2.00 mm2): Belden 9581, Genesis 4408, (2,438 m) Signal 98430, WPW D995. Twisted-pair, shielded 4,875 feet 16 AWG (1.3 mm2): Belden 9575, Genesis 4406 (1,486 m) and 4606, Signal 98630, WPW D991. Twisted-pair, shielded 3,225 feet 18 AWG (0.78 mm2): Belden 9574, Genesis 4402 (983 m) and 4602, Signal 98300, WPW D975. Unwisted, unshielded 3,000 feet (915 m) 12-18 AWG (3.1 —0.78 mm2). PULL STATION NOT-BG12LX 7005d1 .wml Page 2 of 4 - DN-7005 • 08/11/05 One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterf low (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTM module (conventional reverse polarity/city box transmitter). CONTROLS AND INDICATORS LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 5 -16. 12-key pad with full alphabet 17 -20. 4 cursor keys 21. ENTER FIELD-PROGRAMMING FEATURES OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (or- der programming kit VFWARDEN-CD separately). Up- load/download system programming locally to the FireWarden-100 in less than one minute. AUTOPROGRAMMING: Command the FireWarden-100 to program itself (takes less than 30 seconds). In the Auto- Program mode, the FireWarden-100 scans for all possible devices at all addresses, stores the device types, and ad- dresses found, and then loads default values for all op- tions (General Alarm). It also checks for two or more de- vices set to the same address. ONLINE EDIT: While still providing fire protection, the FireWarden-100 may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. ENGLISH LABEL LIBRARY: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat previously used label. PROGRAM CHECK: Automatically catch common errors, such as control modules not linked to any zone or input point. MAINTENANCE ALERT The FireWarden-100 continuously monitors each smoke detector and is capable of reporting maintenance condi- tións. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. AUTOMATIC TEST OPERATION The FireWarden-100 performs an automatic test of each detector every two hours. Failure to meet the test limits causes a TESTF trouble type. System Reset clears this trouble. NFPA STANDARDS The FireWarden-100 complies with the following NFPA 72 Fire Alarm Systems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Su- pervisory). AUXILIARY (Automatic, Manual and Waterf low) (requires 4XTM). REMOTE STATION (Automatic, Manual and Waterf low) (requires 4XTM). PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Watert low, and Sprinkler Supervised). SPECIFICATIONS AC Power - TB1: 120 VAC, 60 Hz, 3.0 A. Wire size: mini- mum 14 AWG (2.0 mm2) with 600 V insulation. Battery (lead acid only) - TB2: Maximum charging circuit: Normal flat charge 27.6 VDC @ 0.80 A. Maximum battery charger capacity: 18 AH. FireWarden-100 cabinet holds maximum of two 18 AH batteries. For 25 - 120 AH batter- ies, use the CHG-120 or CHG-75 Battery Charger and BB- 55 Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG- 120. Remote Synchronization Output - TB2: A 24 VDC, 40 mA signal that mimics the sync signal of NAC 1 and can be utilized by remote power supplies such as the FCPS-24S6/ -24S8. This allows NAC devices attached to the power supply to synchronize with the devices connected to NAC 1 of the FACP. Communication Loop - (standard) T138: 24 VDC nomi- nal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, shielded pair length. Maximum loop cur- rent 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits - TB4: Power-limited cir- cuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal operating voltage: 24 VDC. Current limit:fuseless, electronic, power-limited circuitry. Maximum signaling current per cir- cuit: 2.50 A. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252, UL Listed) for NAGs. Refer to NOTIFIER Device Compatibility Document for listed compatible devices. Programmable and Trouble Output Relays - TB5, TB6, TB7: Contact rating: 2.0A @30 VDC (resistive), 0.5A @30 VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB1, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 0.5 A for powering four-wire smoke detectors. Power-limited circuit. Refer to NOTIFIER Device Compatibility Document for listed compatible de- vices. Nonresettable Power #1(24 VDC Nominal) -TB1, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 0.5 A total DC current available from each output. Power- limited circuit. TB1, Terminals 1 (+) & 2 (-) can be config- ured as resettable 24 V or non-resettable via JP4. NOTE: If using optional XRM-24, total NAC and auxiliary cur- rent draw cannot exceed 6.0 amps. EiA-485 (ACS) - TB6: ACS annunciator connector, Termi- nal 1 (+) and Terminal 2 (-). EIA-485 (TERM) - TB7: Terminal mode annunciator con- nector, Terminal 1 (Out +), 2 (In +), 3 (Out .-), 4 (In -). EIA-232 - TBS: PC/printer connector, Terminal 1 (Trans- mit), 2 (Receive), 3 (DIR), 4 (Ground). DN-7005 • 08/11/05 - Page 3 of 4 CABINET SPECIFICATIONS Door: 18.67 (47.43 cm) high x 15.78" (40.08 cm) wide x 1.08 (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x 15.50" (39.37 cm) wide x 4.37" (11.1 cm) deep. Trim Ring (NFW-TR): 21.62'(54.92 cm) high x 18.62'(47.3 cm) wide. PRODUCT LINE INFORMATION NFW-100: 198-point addressable Fire Alarm Control Panel. Includes 80-character LCD display, single printed circuit board, and cabinet. ACM-8R: Optional plug-in relay module provides 8 Form-C 5.0 A relays. VFWARDEN-CD: Contains panel programming software for Windows®-based PC computer (cable not included). DP-FW-100: Dress panel for FireWarden-100. NFW-TR: Trim Ring for semi-flush mounting. BB-55: Battery box, required to house two BAT-12260 batteries and one CHG-i 20 battery charger. For batteries greater than 26 AH, consult factor,' for housing/mounting arrangements. BB-6: Battery backbox, holds up to two BAT- i 2260 batteries. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH. CHG-120 orCHG- 75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120 or CHG-75 required for charging greater than 25 AH batteries. BAT-12180: Battery, 12 volt, 18.0 AH, (two required). BAT-12260: Battery, 12 volt, 26 AH, (two required; requires CHG-75). BAT-1 2550: Battery, 12 volt, 55 AH, (two required; requires CHG-75). PRT/PK-CABLE: Cable printer/personal computer interface cable. For use with printer or VFWARDEN-CD. Windows® is a registered trademark of Microsoft Corporation. COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-lOOT: Addressable low-profile photoelectric smoke detector with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of-rise. ND-100: Photoelectric duct smoke detector. ND-100R: Photoelectric duct smoke detector with relay. NMM-100: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style 0 (Class A) IDC. NMM-i OOP: Miniature version of NMM-1 00. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factor,' for compatible detectors. NDM-i 00: Dual Monitor Module. Same as NMM-1 00 except it provides two Style V (Class B) only lDCs. NC-100: Addressable Control Module for one Style V/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NMM- loop. NOTE: Formore information on Compatible Addressable De- vices for use with the Fire Wa rden-100, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100/ NP-100T (DN-6995), Nl-lOO (DN-6996), NH-100JNH-I00R (DN- 6997), ND-lOO/ND-IOOR (DN-7006), NMM-100/NMM-I00P/ NDM-lOO/NZM-100 (DN-6999), NC-lOO/NC-IOOR (DN-7000), andNOT-BG12LX (DN-7001). COMPATIBLE ANNUNCIATORS EIA-485 interface: Built into the motherboard. AFM-LED Zone Series: LED-type fire annunciators ca- pable of providing up to 99 software zones of annuncia- tion. Available in increments of 16 or 32 with expandable (AFM-X Series) and non-expandable (AFM Series) con- figurations to meet a variety of applications. ACS/ACM Annunciator Series: Allows annunciation of loop modules and detectors. 1DM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80- character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 FDU-80 an- nunciators may be connected to the EIA-485 terminal mode serial interface on the FireWarden-100 motherboard. NOTE: For more information on Compatible Annunciators for use with the Fire Warden- 100, see the following data sheets (document numbers) AFMIAFM-X Series (DN-0056), ACM- BR (DN-3558), ACS/ACM Series (DN-0524), FDU-80 (DN- 6820), LDM Series (ON-055 1). AGENCY LISTINGS AND APPROVALS See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the basic FireWarden-100 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory Page 4 of 4 - DN-7005.08I11/05 CALIF ORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:235 Page 1 of I CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model Fire Warden 100 addressable control unit. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:208 12-09-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager July 20, 2004 DN-6820- D-123 FDU-80 () NOTIFIER ® 80-Character Liquid Crystal Display Fire Annunciator Section: Annunciators GENERAL The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER AFP-300, AFP- 400, AFC-600, and NFS-640 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and dis- plays complete system point status information. Up to 32 FDU- 80s may be connected onto the ElA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. NOTES: The FDU-80 is compatible with the NOTIFIER AFP-300/ 400 Rev. 3.62 or higher, AFC-600 (all revisions), and NFS- 640 Rev. 2.01 or higher. The FDU-80 can be used on the same data loop as the LCD-80/LCD-80TM annunciators revision 1.6 software or higher. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. No programming necessary - FDU-80 connects to the terminal mode port. Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER PIN 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER SBB-3 surface backbox. OPERATION The FDU-80 annunciator provides the FACP with point an- nunciation with full display text on an 80-character LCD dis- play. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. 110!428:209 LISTED CS100 S635 MEA 245-00-E FDU-80 Annunciator The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communica- tions (two in and two return); and two for the 24 VDC regu- lated power. Dip switches control local functions such as: piezo disable, control switches/key switch disable, transmit] receive mode. I NSTALLATI ON The FDU-80 can be semi-flush mounted to a 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10 103) or three-gangable electrical switchboxes. Alter- nately, an SBB-3 surface backbox is available for surface- mount applications. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our ISO 9001 I product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. E'1 =i d I I 1 .1 1 For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203)484-7118 MI]INERINI &MANVFAZI1IIlN N OTI F I E Re 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS Made in the U.S.A. FDU-80 Terminal Mode EIA-485 return [(2-wires) ne ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. 10103 Three-gang electrical box, minimum 2.188 (5.556 cm) deep, for semi-flush-mount applications. SBB-3 Three-gang surface backbox for surface-mount applications. FDU-80 TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between I EACH DEVICE in the ElA-485 loop Terminal Mode -., r FDU-80 \ 24 VDC Up to 6,000 ft. (1828.8 m) / back from last device j to end of EIA-485 loop AFP-400 Notes: EIA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to FDU-80 annunciators and back to FACP (6,000 feet [1828.8 m] total). Circuit is power-limited. Up to 32 FDU-80 annunciators may be used on the EIA-485 circuit. When multiple FDU-80s are used, certain panels will require additional power supplies (refer to panel documentation). Between each FDU-80 annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. On the AFP-300/400, software revision 3.62 or higher is required. MOUNTING TO BACKBOX(ES) The FDU-80 annunciators can be semi-flush-mounted in a three-gang electrical box with a minimum depth of 2.188 (5.556 cm) (NOTIFIER PIN 10103). The FDU-80 annunciators can be mounted in three gangable electrical switch boxes connected together. NOTE: Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. 5.813" (14.764 cm) wide x 4" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (NOTIFIER P/N 10103, shown at right). FDU-80 flange Mountir Holes (4 Page 2 of 2 - DN-6820 • 07/20/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:209 Page 1 of 1 CATEGORY: Annunciators LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model FDU-80 remote fire annunciator. Unit is a compact 80-character, backlit LCD fire annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. 09-21-2000 ;. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager NOTIFIER® by Honeywell GENERAL The NP-100 and NP-100T addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelec- tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden-lOoAddressable Fire Alarm Con- trol Panel (FACP). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emergency personnel quickly locate a tire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 rn/sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0"(10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient June 15, 2005 DN-6995 • Al -310 NP-100 and NP-100T Addressable Photoelectric Detectors Section: Addressable ® California State Fire Marshal <*> 7272-0028:231 APPROVED LISTED 51115 MARYLAND M EA State Fire Marshal 243-02-E Vol. II Permit # 2173 NP-100 i-°_.t --..- - - with B71OLP base- .- .. 6934ph01.jpg - I NP-100T with B71OLP base 6935ph01 59 protection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA © 24 VDC. LED current: 6.5 mA © 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) Installed In B71OLP base. Height: 2.1" (5.33 cm) installed in B710LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 1200F); for NP-100T 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 1200F). Relative humidity: 10% - 93%, non-condensing. V This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 • N OTI Fl E R ENCINIFIING & MANOME1UIING by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SY STEMS - - - DN-6995 • 06/15/05 - Page 1 of 2 APPLICATIONS Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, espe- cially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are de- signed to commercial standards and offer an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T- taps" or branches are permitted for Style 4 (Class B) wiring. OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) with- out sending an alarm level signal. Because of its unipo- lar chamber, the NP-100(T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to a FireWarden-100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100 for record keeping. PRODUCT LINE INFORMATION NP-100 Addressable photoelectric detector; B71OLP base included.* NP-100T Same as NP-100 but with thermal element; B71OLP base included.* RA400Z Remote LED. Mounts to a single-gang box. B71OLP Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224Bl Plug-in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN-6994). Diameter: 6.2 (15.75 cm). Mounting: 4.0 (10.16 cm) square box with or without plaster ring, 4.0' (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). "Prior to 03/28/05, the B71OLP base was sold separately. Page 2 of 2 - DN-6995 • 06/15/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-lOOT photoelectric type smoke detectors. Model NP-lOOT has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy .11 Program Manager NOTIFIER® by Honeywell GENERAL The NOTIFIER NOT-BG12LX is a state-of-the-art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for NOTIFIER's addressable FireWarden-100 fire alarm control panel. Because the NOT-BG12LX is addres- sable, the control panel can display the exact location of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES Aesthetically pleasing, highly visible, dual-action design. Meets ADA 5 lb. maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. Mounts, semi-flush, to a standard single-gang (2.125° [5.398 cm] minimum depth), double-gang, or 4.0' (10.16 cm) square electrical box. When the handle latches in down position, the word "AC- TIVATED" appears at the top of the handle in bright yel- low to clearly indicate the station has been operated. Key/lock reset; needs only a 1/4-turn to lock/unlock. Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- vided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mount- ing on a standard single-gang, double-gang, or 4.0(10.16 LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. June 15, 2005 DN-7001 •A1-380 NOT-BG12LX Addressable Manual Pull Station for FireWarden-1 00 Section: Addressable Patented, U.S. Patent No.. D428,351; 6,380,846 U.S. Patent Pending: 091686,286 MEA® California State Fire 67-02-E Vol. IV Marshal 7150-0028:199 LISTED <@> S692 APPROVED The NOT-BG12LX Addressable Manual Pull Station cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more Information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 _ NOT! Fl ER" ENG11011111111 I MANUMZIUIJNG by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-7001• 06/15/05 - Page 1 of 2 Maximum SLC loop current: 230 pA. INSTALLATION The NOT-BG12LX can be semi-flush mounted into a single- gang, double-gang, or standard 4.0(10.16cm) square elec- trical outlet box, or surface mounted to the Model SB-10 or SB-I/O surface backbox. If the NOT-BG12LX is semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4.0 (10.16 cm) or double-gang boxes (not with single-gang boxes). CONSTRUCTION L Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bot- tom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action re- sets the handle; closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops. Each manual station, on command from the control panel, sends data to the panel representing the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION NOT-BG12LX Dual-action addressable pull station. Includes key lock/reset feature. SB-10 Surface backbox. SB-I/O Surface indoor/outdoor backbox. BG-TR Optional trim ring. V CD Is TERMINAL CONNECTIONS 1 SLC(—) J2 SLC(+) Back of station without door. Detafl of 07 BREAKAWAY TAB* 150 i ADDRESS 0 h 17% , 2 (ff4J Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 - DN-7001• 06/15/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-6302 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-I2LAO, NBG-I2LAOB, NBG- 12-LO, NBG-I2LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-I2LWP, NBG- 12L, NBG-12LX, NBG-12LA, NBG-I2PS, NBG-12LSP, NBG-I2LPS, NBG-I2LPSP, NBG- I2SP, and NOT-BG12LX fire alarm pull boxes. *All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-I2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's pnnted installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-12LAO, NBG-12L0, NBG- 12LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *Rev. 02-22-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy - Program Manager NOTIFIER® by Honeywell GENERAL Four different monitor modules are available for NOTIFIER's FireWarden-100 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke detectors (NZM-1 00). NMM-100 —The NMM-100 Monitor Module is a standard- sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. NMM.IOOP —The NMM-100P is a Miniature Monitor Mod- ule (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) cir- cuit. Its compact design allows the NMM-100P to be mounted in a single-gang box behind the device it is moni- toring. NZM-100 - The NZM-100 Interface Module is a stan- dard-sized module used to monitor and supervise com- patible two-wire, 24 volt, smoke detectors on a Class A (Style 0) or Class B (Style B) circuit. NDM-100 - The NDM-100 Dual Monitor Module is a stan- dard-sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises two Class B (Style B) circuits of dry-contact input devices. NMM-100 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. NMM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class D) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is re- June 15, 2005 DN-6999 • Al-350 Addressable Monitor Modules for the FireWarden-100: NMM-100, NMM-1 OOP, NZM-1 00, NDM-1 00 Section: Addressable California State Fire ® MEA Marshal 72-01 -E Vol. 11 I 7300-0028:230 LISTED (except NOM- 100) (except NDM- 100) S635 <*> APPROVED NMM-100 and NZM-100 quired for supervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. NMM-100 Operation - Each NMM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 hA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125" (5.398 cm) deep box. rw This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I I NoTi FR ER° INGINERING MANUMMIUNG by Honeywell 12 Clintonville Road, Norlhford, Connecticut 06472 QUALITY SYSTEMS DN-6999 • 06/15/05 - Page 1 of 3 NMM-1OOP MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the FireWarden-100. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P is intended for use in in- telligent, two-wire systems where the individual address of each module is selected using rotary switches. It pro- vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. 1415 0 i ADDRESS I 0 1 13/\2 2 f ? LOOP I 1 Ifl 09.4 65 9 87 6 f TENS ONES OlUj 0 C) __ill cc I NMM-100P Applications - Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact devices. May also be used to monitor nor- mally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Cir- cuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP Operation - Each NMM-100P uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). NMM-100P Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 pA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x 0.5 (1.270 cm) deep. Wire length: 6.0° (15.24 cm) minimum. Page 2 of 3— DN-6999 • 06/15/05 NZM.100 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source (resettable). High noise (EMF!RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in- telligent, addressable systems, where the individual ad- dress of each module is selected using built-in rotary switches. This module allows intelligent panels to inter- face and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com- patible with the module. NZM-100 Applications - Use the NZM-100 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style 0 (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100 Operation - Each NZM-100 uses one of 99 (FireWarden-1 00) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100 DUAL MONITOR MODULE Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 99 (FireWarden-100) uses two addresses per module. LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independent two-wire fault-toler- ant Initiating Device Circuits (lDCs) at two separate, con- secutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. NDM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, waterf low devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. NDM-100 Operation - Each NDM-100 uses two of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NDM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4.0° (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4.0° (10.16 cm) square x 2.125" (5.398 cm) deep box. Accessories: SMB500 electrical box. INSTALLATION NMM-100, NZM-100, and NDM-100 modules mount di- rectly to a standard 4.0° (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and in- stallation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances and regulations. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module. NZM-1 00 Two-wire detector monitor module. NDM-100 Dual monitor module. SMB500 Optional surface-mount backbox. I I MOUNTING DIAGRAMS for standard-sized modules ON-6999 • 06/15/05 - Page 3 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: 7300-0028:230 Page 1 of 1 Misc. Devices/Control Unit Accessories Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 Models NMM-100P, NMM-I00, and NZM-100 monitor modules; Models NC-IOOR and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. 15-32 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-0075:185 10-20-2004 ..• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or /. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Helping People Take .Aton SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW multi-candela strobe with field selectable candela settings of 15/301751110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12124-8CP and PS-12124-8MP Power Supplies with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, Inc. All rights resezved. W00 New New Look IL A '1 ' . \ Series RSS Series RSSP RSS Round - .-.- Multi-Candela Indicator (bottom of Strobe Lens) Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30! 751110cd or 1351185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15130175195cd or 1151177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire NOTE: All CAUTIONS and WARNINGS are identified by the symbol. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of Ito 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 F to 120 F (0" C to 49" C) and maximum humidity of 93% (± 2%). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSSIRSSP - Wall Mount RSS - Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP * RMS current ratings are per UL average RMS method. UL max current - 24VDC a OUfl rating is the maximum RMS current within the listed voltage range (16-33v 121575W Models for 24v units). For strobes the UL max current is Usually at the minimum ____________ _____________ listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 12 vdc 0.152 see installation instructions. UL max* 0.255 Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. 4 THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, ANDJOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BETAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams 11 ISERIES RSSIRSSP APPLIANCE FROM + + TO NEXT PRECEDING - - APPLIANCE APPLIANCE, SYNC OREOLR MODULE, POWER SUPPLY OR FACP I 1 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE + NAG SYNC CIRCUIT OUT OJ1l Ø 0 .IN1 RSS RSS RSS FACP MINUS 0+ AUDIBLE MINUS 2 IN 2 RSS RSS ROBE NAC 0. OUT 2 C!RCUIT RETURN OBE/PLATE ASSEMBLY BLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT I FROM APPLIANCE PRECEDING - 7—W - APPLIANCE, SYNC OREOLR MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM 4. _________ ______ I III PRECEDING + TO NEXT. P APPLIANCE OR - FACP - ORBOIR SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F +STROBE STROBE 0— A NAC Cfr:u —,Audible ID F 3EOLR -Audible SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Strobe NAC Cir. Sync tss RSS DSM #2 A Strobe NAC Cir. SYncfl€s € 5!_ % Strobe NAC Cir. Sync RSS RSS DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12!24-8CP or PS-12/24-8MP Series PS-12/24-8MP oumurs I]i! M. !iiIi EOLR F 14 - 4-CLASS A OR AS RSS C 2-CLASS P AS RSS Series PS-121244MP FROM + --lr — I+I_"" +TONEXT PRECEDING STROBE OR S1R.S',NC - - - - - - - - ER MODULE. POWER SUPPLY ORFACP STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For Wring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/11Ocd or 135/185cd for wall mount and 15130/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12124-8CP and PS- 12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 100mm European type backboxes, orthe SHBB Surface Backbox. If required, an NATP (Notification Appliance Tnmplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. OTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with rMeelock, Inc. standard terms and conditions. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options*** Square or Round Agency Approvals UL MEA CSFM - FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X SS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 31581 - X IX 115/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X * * RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X * * RSSWP2475WFR** 9013 X - X 77*F X X X - X 180@ B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW* 3034 X - X 180@ 77-F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15(75onAxis) - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X X 135/185 X I X B,D,E,F,G,H,J,N,O,R,X Square X X X * All models sync with Wheelock SM, DSM or PS-12124-8CP or PS-12/24-8MP. *PENDING # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. **Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY NATIONAL SALES OFFICE Made in USA Distributed By: 1-800-631-2148 J. rot WWAr M Canada 800 397-5777 E-mail: lnfocäwhee!ockinc.com httD://www.wheelockinc.com WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S041001/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ, 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 24100 24100 24100 24100 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, *RSS24MCWH *RSS..24MCWHR *RSSP..24MCWH *RSS..24MCCH *RSS 24MCCHR, and *RSSP..24MCCH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FWR Candela 15=5cd, 157515/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW--Selectable 15cd, 30cd, 75cd or 1 10c RSS-24MCC, RSS-24MCCR and RSSP-24MCC - Selectable 15cd, 30cd, 75cd and 95cd *RSS24MCWH *RSS24MCWHR, *RSSP24MCWH - Selectable 135cd, 185cd *RSS..24MCCH *RSS24MCCHR, *RSSP24MCCH - Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix —W, wall mount only. Models with suffix —C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and ULlabel. APPROVAL: Listed as strobe light suitable for the hearing impaired when usJ with separately listed electrically compatible fire alarm control units. For synchronizatn strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation lnstriJtjon Manual for details. *Rev. 02-03-04 NO) This listing is based upon technical data submitted by the applicant. CSFM Fire Engir and/or other data but does not make an independent verification of any claims. recommendation of the item listed. This listing should not be used to verify correct criteria. Refer to listee's data sheet, installation instructions and/or other suitable ml Date Issued: MAY 21, 2005 Listing Expires ,3(, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I staff has reviewed the test results listing is not an endorsement or tional requirements or installation on sources. wheeiock - HTM Helping People Take Action5M SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 151301751110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130175195cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-I 2124-8CP and PS-I 2/24-8MP Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 Copyright 2004 Wheèlock Inc. All rights reserved. • _,•.•t_, Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADA/NFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/751110cd or I35/I85cd (Multi-Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of I5I30/75195cd or I15/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of Ito 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" Is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (cd) AS-24MCW 24 16.0-33.0 15/30175/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0 -33.0 15 (75 on Ads) AS-I21575W 12 8.0-17.5 15(75onAds) AS-24MCC 24 16.0 -33.0 15/30175/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75 Q -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AK 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL464@lOft. Anecholc dBA@lOft. Contnm Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241675W AS-24MCW - AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 High (99) dBA ULmax° 0.080 0.121 - 0.088 0.125 0.200 - 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 24vdc 0.033 0,080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0230 0.305 Med (95)dBA UL max* 0.043 0.107 - 0.074 1 0.110 1 0.190 - 1 0.253 0.340 1 0.465 1 0.080 1 0.122 0.201 0.269 0.340 0.465 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 1 0.295 1 0.056 1 0.082 1 0.132 1 0.173 1 0.220 1 0.295 Low (90) dBA ULmax° 0.021 0.100 0.068 0.105 0.182 0.245 0.335 LO.460 1 0.074 1 0.113 1 0.198 0.263 1 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16- 33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. AH42 AS-121575W HI h 99 dBA g 12 dc 0.163 0.260 UL max' 0.192 0.320 Med (95) dBA 12 vdc 0.076 0.195 UL max° 0.108 0.275 Low(90) dBA 12 vdc 0.039 0.175 UL max' 0.058 0.265 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS.24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Seles AH, (P83641) Series AH-WP AND "GENERAL INFORMA1'ION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREASAND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams 11 SERIES AS APPLIANCES NON-SYNCHRONIZED FROM + TO NEXT APPLIANCE OR EOLR OR FACP PRECEDING - APPLIANCE SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE sm — A NAC STROBE Circuit ROBE *Audibl, EOLR - Audibl, Audible NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Audible NAC Cir. DSM #1 Strobe NAC cir.SYflC F 0 DSM #2 AudbleNACCi Strobe NAC cir Audible NAC Ch DSM #3 P Sync Strobe NAC Cir. DSM Interconnecting wiring shown. Maximum of twenty (20) ES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP PS-12124-8MP EOLR F 14 ouTPuT S I % "I ASS H 2A ____I A OR S.A6.PS-12/24-BCP ° For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). 01 Architects and ecitica tions The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-I 2/24-8CP or PS-i 2/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Model Order Code Strobe Candela Non-Sync Sync wISM, DSM PS-12124.8cP or PS144MP 24 VDc 12 VD C wall Mount M cfl Mount Mounting 0p8ons Agency Approvals - Ut. MEA CSFM - FM - BFP AS-24MCW-FR 9024 151301751110 X X X - X - A.B,D,E,F.l-t,J,N,O,RX x x x x x AS-24MCW-FW 9025 15130175/110 X X X - X -A,B4O,E,FQHJ,N.O,RX X X X X X AS-241VIC\M4-FR 3468 135/185 X X X - X - A,B,D,E,F.GH,J.N,O,RX X X X X * AS44MCWt-l-FW 3469 135/185 X X X - X - A,8D,E,F,HJ.N.O.RX X X X X * AS-241575W-FR 7405 15 (75 on Ads) X X X - X . A,a,DE,F,HJ.N.O,R,X X X X X X AS-121575W-FR 7410 15 (75 on Ads) X X - X X - A,B,D,E,F,H,J.N.O,R,X x X X x x AS-24MCC-FR 3161 15/30115/95 X X X - - X A.B,D,E,F,H.J.N.O.R.X X X X X * AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N.O,R,X X X X X * AS-24MCCH-FW 3467 115/177 X X X - - X A,B,DE.F,H,J,N,O.R,X X X X X * ASWP-2475W-FR" 9012 75 © -31 F X X X - X - I (see Data Sheet S9004) X X X X X AH-24-R 7892 - X X X - x x A,B,D,E,F,G4.J,N,O,R,X x x X X X AH-24-W 7893 - X X X - X X A,B,D,E.F.(H.JN,O,R.X X X X X X AH-12.R 7891 - x x - x X x A,B,D,E,F,HJ,N,O,R.X X X X X X A1412-W 7894 - X X - X X X X X X X X AH-24WP4" 7416 - X X X - X X K X X X X AH-12WP-R" 7415 - X X - X X X K X X X - X *PENDING Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. "For Weatherproof Series AS/AH specifications see data sheet S9004. "Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA ember Distributed By: WI-IEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S810001/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230,-2430, -121575, -241575,-2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP*2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, llOcd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. Corrected 08-20-04 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-I2WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Corrected 08-2-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or .• . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21, 2005 Listing Expires June 30, 2006 if Authorized By: DIANE K. AREND, Senior Deputy Program Manager (a NOTIFIER® GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-2456/-24S8 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAG) expansion (to support ADA re- quirements and NAG synchronization) or auxiliary power to support 24-volt system accessories. The FGPS-24S61-24S8 provides regulated and filtered 24 VDC power to four notifi- cation appliance circuits configured as either four Class B (Style Y) or Glass A (Style Z, with ZNAC-4 option module). Alter- nately, the four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FGPS-24561-2458 also contains a battery charger capable of charging up to 18 AH batteries. FEATURES UL-Listed NAG synchronization using System Sensor, Wheelock, or Gentex "Commander"' appliances. Gascadable for up to ten power supplies (four for Gentex) with strobe timing maintained. Operates as a "sync follower" or as a "sync generator" (de- fault). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAG expander mode) or jumpered per- manently "ON" (stand-alone mode). Four Glass B (Style Y) or four Glass A (Style Z, with ZNAC-4 module) NAGs. 6-amp (FGPS-24S6) or 8-amp (FGPS-24S8) full load output, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp (FGPS-24S6) or 6-amp (FGPS-2458) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (A77-716B). In stand-alone mode, output power circuits may be config- ured as: resettable (reset line from FACP required), non- resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AC trouble report selectable for immediate or 8-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, locking cabinet - 15" (38.1 cm) high x 14.5" (36.83 cm) wide x 2.75" (6.985 cm) deep. Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. July 20, 2004 DN-6927 E-30 FCPS-24S6 and FCPS-2458 6-Amp and 8-Amp 24-Volt Remote Power Supplies -- Section: Power Supplies California State Fire Marshal © 7315-0028:225 LISTED APPROVED S635 MEA 299-02-E Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. STANDARDS and CODES The FCPS-2456/-24S8 complies with the following standards: NFPA 72 National Fire Alarm Code. UI 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UI 1481 Power Supplies for Fire Alarm Systems (stand- alone mode). SPECIFICATIONS Primary (AC) power: FCPS-24S6/-24S8: 120 VAC, 60 Hz, 3.2 A maximum. Wire size: minimum #14 AWG (2.0 mm2) with 600 V insulation. Control Input circuit: Trigger input voltage: 9 to 32 VDC. Trigger current: 2.0 mA (16-32 V). Per input: 1.0 mA (9- 16 V). Trouble contact rating: 5 amps at 24 VDC. C NOTIFIER® Is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS09001 product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. d I I r •I For more Information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203)484-7118 ENSINEEIIING A MANUMIING NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6927 • 07/20/04 - Page 1 of 3 Auxiliary power output: specific application power 500 mA maximum. Output circuits: +24 VDC filtered, regulated. 3.0 amps maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum; for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum charge current: 1.5 amps Maximum battery capacity: 18 AH. APPLICATIONS Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-24S6) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZF'lAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-2456) or up to 6.0 amps (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs.. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *Addressable FACPs are capable of locating control and monitor Style Y NAC or modules at distances of up to Door Holder 10,000 feet (3048 meters). Power S AGENCY LISTINGS Output #4 Ot AND APPROVALS SYNC FOLLOWER/GENERATOR NOTE In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-24S8 can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attached to the FCPS. When the FCPS-2456/-2458 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-2458 is configured (via DIP switch set- tings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. PRODUCT LINE INFORMATION FCPS-2456: 6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5' [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. FCPS-24S8: 8.0 amp. 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75"[6.985 cm] deep), and installation instructions. ZNAC-4: Class A (Style Z) NAC option module. A77-716B: 12/24 VDC end-of-line relay for monitoring four- wire smoke detector power. BAT-1270: Battery, 12 volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1109). NOTE: All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble Contact Output 41 yleY NAC Style Y NAC Style YNAC itput #3 Output #2 Output #1 See the first page of this data sheet for listing agencies and file numbers. These listings and ap- provals apply to the FCPS-24S6 and the FCPS-24S8. In some T. cases, certain modules or appli- ) AC cations may not be listed by cer- power thin approval agencies, or listing may be in process. Consult fac- tory for latest listing status. IFCPS INPUT/OUTPUT FUNCTIONS are programmable by SW1 DIP switch settings 24 VDC Specific Application Power NAC Control I Input #2 . (from FACP) NAC Control Input #1 (from FACP) 4&M Sync Input SIMPLIFIED BLOCK DIAGRAM Battery Charger Page 2 of 3 - DN-6927 • 07/20/04 I' CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:225 Page 1 of I CATEGORY: Power Units LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:206 1-24-20031(1< This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 5, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2006