HomeMy WebLinkAbout2714 LOKER AVE W; ; FA160045; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160045 2714 LOKER AV Job Address: WEST Permit Type: FALARM Parcel No: 2090813200 Lot #: 0 Reference No.: Status: ISSUED Applied 8/18/2016 Approved: 9/6/2016 Issued: 9/6/2016 PC #: Inspector: Project Title: A4D STE. 300: INSTALL A NEW FIRE ALARM SYSTEM FOR THE TENANT IMPROVEMENT OF THE THIRD FLOOR OF AN EXISTING BUILDING. INSTALL NOTIFICATION DEVICES IN THE COMMON AREAS OF THE FIRST AND SECOND FLOORS. HVAC UNITS TO BE WIRED FOR GLOBAL SHUTDOWN BY HVAC CONTRACTOR. CELLULAR COMMUNICATION MEETS NFPA 72 STANDARDS FOR SINGLE PATH COMMUNICATION. FUTURE TENANT IMPROVEMEN OF 1ST AND 2ND FLOORS WILL REQUIRE ADDITIONAL PERMITS. Applicant: Owner: JMG SECURITY CBLLLC 17150 NEWHOPE SUITE 109 6183 PASEO DEL NORTE #280 CARLSBAD CA 800-900-4564 Submittal Package for: A4D Performance 2714 Loker Avenue West, 3rd Floor Carlsbad, CA 92010 JMG Security Systems, Inc. 17150 Newhope Street, #109 Fountain Valley, CA 92708 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Cellular Communicator Input Module NAC Module Power Supply Smoke Detector Manual Pull Station Strobe Horn/Strobe FA1 60045 2714 LOKERAVWEST DPG 8/1/2016 0 Powerful system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XRI50FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR55OFC Up to 142 two-wire smoke detector or fire initiating zones on XR1 5OFC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .7 Amps 12 VDC supervised bell output Up to 506 fully-programmable Form C relays Serial 3 Digital Dialer or CID reporting to multiple receivers Eight communication paths between the panel and Central Station Built-in remote or on-site feature upgrade capability 12.000 event buffer Multi-lingual menus available by user, - - - Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming XRI50DNFC/XR55ODNFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network Monitoring1M Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available -------------------------------------------------------------------------------- Intrusion ftire.IAcce.j Network I Cellular .. .. L. XR150FC & XR550FC FIRE PANELS The XRI 5ODFC and XR5500FC provide basic fire monitoring for any single site application. The XR1 5ODNFC and XR55ODNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for Local NAC operation and DACT. NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XR150FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION 12 or 24 VDC NAC1 12 or 24VDC Mi Sync Module Strobe ni-Horn NAC1 :I 12 or 24 VDC NAC2 Power Supply Sync Module Horn Strobe 12 or 24 VDC NAC 2 505-12 or other 1 2/24VDC UL Motor Bell Commercial Fire Approved Digital Power Supplies Supplies Annunciator Bus LLS 630F Fire Command Center :-- £ -'-4- Digital SLC Loop 2 Digital SLC Any expansion device Loop 1 can operate on SLC Loop 1 or 2 Additional 630F Fire Command Centers FLEXIBLE COMMUNICATION The XR1500NFC and XR5500NFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation Literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted Line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path. the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds afterthe reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindowsTM. The XR150FC and XR550FC include an interface connection for installers to use to connect a Laptop computer. u.ul I U uvI tIle Paz,'.,J SPEC SHEET EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters. and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR550FC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature aliows a single technician to check the panel response to fire, burglary. panic and supervisory zones. OUTPUTS The XR150FC and XR550FC allow the use of two SPOT relay outputs and four open collector outputs, that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. FIRE ZONE PROGRAMMING For additional flexibility, keypads attached to Program zones for fire, fire verify, fire retard. BUILT-IN PROGRAMMER the XR1 50FC and XR550FC panels can display presignat, cross zoning, or fire supervisory. AND DIAGNOSTICS keypad Status List and User Menu text using This flexibility allows the ability to match No programming device is required, enabling multiple languages. The user has the option individual zone characteristics to the needs installers and service technicians to fully to select the language to use. of any area in the fire installation, program the system and run diagnostics from any DMP LCD keypad. Check the electrical STATUS LIST ZONE EXPANSION state of zones, find individual zone numbers, To provide maximum system flexibility, fire The XR15OFC andXR550FC provide up to 570 check the LX-Bus for Missing. Overlapping zones may be programmed to display at a zones, programmable for a variety of fire and/or Extra zones, and much more, all from specific keypad. In this manner, all fire zones applications. The system provides Class B any DMP LCD keypad. can be monitored in one location and other 12VDC powered zones, two on-board and zones can be programmed to display and be four on the 715 Module, plus eight panel FLASH UPDATEABLE monitored at different keypad locations. burglary zones. Up to 60 zones are available The XR1 SOFC and XR550FC panels accept onl5 keypad addresses and uptolOozones software updates from a remote location 12,000 EVENT MEMORY are available on each built-in LX_BusTM using using Remote LinkTM software. When new Allows the user to view the last 10,000 Expansion Modules. XR1 5OFC/XR55OFC feature updates release, door accesses or 2,000 system events that perform the flash update remotely. A 0,.,,. Intrusion I Fire I Access I Network I Cellular KEYPADS 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS 263C COMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (All require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style WIX Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12/LX 5 Amps © 12 VDC 505-12L 5 Amps ©12VDC 505-12A 5 Amps ©12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke, Clean Me 521LX/LXT Addressable Smoke/Heat. CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18 Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatable with Central Station Receivers that accept Standard dO. DO. or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS 1100X Receiver 1100XH High Power Receiver 1100R Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365, 366. 368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide (LT-1297). XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance ORDERING INFORMATION XR150DFC-R XR150 Fire Control Panel XR1 5ODNFC-R XR1 50 Fire Control Panel with Network XR5500FC-R XR550 Fire Control Panel XR550DNFC-R XR550 Fire Control Panel with Network. Intrusion I Fire I Access Network I Cellular 2500 North Partnership Boulevard 800.641.4282 I dmp.com Springfield. Missouri 65803-8877 Designed. Engineered & Assembled in Springfield. Missouri SIGNALING NYC MEA LISTED - St' DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and commercial fire applications. The 630F provides 32-character full text LCD display of system events and menu prompts for efficient, easy use. The keypads offer simple, one-button access to common features, including: Silence alarms Reset sensors Test the system Perform a fire drill The 692F includes a highly visible LED annunciator. 33©- r9 (fl/ r 692F FEATURES Three status LEDs: Silenced, Trouble, and Power 10 zone LEDs: 5 Trouble LEDs and 5 Alarm LEDs No addressing required - use as many as you need Zone monitoring feature for all zones Four short tones indicate an unsuccessful keypad operation Quick key on keypad for changing user code Audible tone on each key press 630F FEATURES Zone LEDs: Normal, Trouble, 32-character LCD display Bypassed, and Alarm conditions Flush or Surface mount Keyswitch enables single button operation Full operation with authorized code Built-in diagnostics AC Power, Trouble, Alarm LED Compatible with XR5FC/XR5SL, XR100IXR500 Series, or XR2500F System events display in plain English FIRE COMMAND FEATURES Simple harness connection to 4-wire keypad bus At-a-glance system status Powered from panel or auxiliary power supply Optional backboxes for conduit or wall mount applications Attractive non-obtrusive designs 2-button Panic keys 630F REMOTE ANNUNCIATOR The 630F Fire Command Center offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. The backbox and trim frame provide an attractive installation. The keypad can either be flush- mounted or surface-mounted. 630F Keypad SINGLE-BUTTON OPERATION The 630F Fire Command Center has a factory installed keyswitch that enables the four function buttons-Alarm Silence, System Reset, System Test, and Fire Drill. The user can also access these four functions and many more through the User Menu by entering a valid user code. BUILT-IN DIAGNOSTICS An internal diagnostics program lets installers and service technicians test the operation of the keypad at any time without disabling the system. SUPERVISED AND UNSUPERVISED OPERATION The 630F keypad can be programmed for supervised or unsupervised operation on the keypad data bus, increasing the overall number of keypads you can install to provide maximum flexibility. When supervised, the keypad occupies its own address. Unsupervised operation allows you to install multiple keypads on the bus with the same address. The 692F is always set as unsupervised. 692F FIRE COMMAND KEYPAD The 692F Fire Command Keypad offers highly visible LED annunciation of alarm and trouble conditions on DMP XR5FC and XR5SL Commercial Fire Panels. It provides individual zone alarm and trouble LEDs, status LEDs, an internal buzzer, 2-button functions. The 692F is cased in a durable Red plastic housing with a removable base for easy installation. STATUS LEDS The Green Power LED lights when primary AC or DC power to the panel is at an acceptable level and flashes when its battery is low or missing. AYellow Trouble LED turns on when either the panel has failed to communicate with the central station receiver or when phone line 1 or 2 is in a bad condition. The 692F also uses a Yellow Silenced LED to indicate when the panel Bell Output has been silenced. ZONE LEDS Zone LEDs indicate the status of the first five zones. Each zone has a trouble and alarm LED to indicate at-a-glance zone status. KEYPAD FUNCTION KEYS There are four clearly labeled function keys on the 692F keypad. The SILENCE, RESET, TEST, and CODE function keys allow the user to press one key to initiate operations. As an added security measure, the user must enter a valid security code after pressing one of the function keys. 692F Keypad Fire Display Panic Keyboard User Operating Operating Current Command Zones Type Keys Compatible Panels Red in Brightness Voltage Standby Alarm Model Alarm 630F None LCD Yes XR5FC/XR5SL, XR100/XR500 Series, No Yes 12 VDC 63mA 92mA XR2500F 692F None LED I Yes I XR5FC/XR5SL (First five zones only) I No I Yes 1 12 VDC 1 30mA 70mA 530F SPECIFICATIONS Operating Voltage 8.5 to 15 VDC Current Draw 63mA standby, 92mA maximum Trim Frame Dimensions 10.4" W x 7.0" H x 1.7" D Backbox Dimensions 8.75" W x 6.375" H x 2.5" D Panel Cnmntihilitv )(RflO Series XRIUO Series KEYPAD ACCESSORIES 635 1.75" 630F Keypad Conduit Backbox 635F 25" 630F Keypad Conduit Backbox 695 1.5" Keypad Conduit Backbox 696 1/2" Keypad Backbox 699 Kevoad Deckstand XR2500F -. 300 4-wire Replacement Harness 92F SPECIFICATIONS LED Keypad Housing Operating Voltage 8.5 to 15 VDC LISTINGS AND APPROVALS Current Draw 30mA standby, 70mA maximum California State Fire Marshal (CSFM) Dimensions 6.8" W x 5.0" H x 1.1" D FCC Part 15 Panel Compatibility XR5FC and XR5SL Underwriters Laboratories (UL) Listed ANSI/UL 864 Control Units for Fire Protective Signaling ANSI/UL 985 Household Fire Warning For additional information, access www.dmp.com and select Compliance. 0 o — r4 — — Co = - -,----- ------------------------.------.-------*------------ -------- 0 -- 2500 North Partnership Boulevard - Digital MonitoringPCodoct .' - -. Springfield, Missouri 65803-8877 - - UL Listed CDMA & HSPA+ Cellular Communication for Fire Alarm Control Panels The 263C/263H, when installed with a DMP XR1 50/XR150FC or XR550/R550FC Panel. is UL approved as a primary (standalone) fire communicator with no backup, and is approved as a fire slave communicator, compatible with any FACP. The 263C/263H provides a dependable communications Link between your alarm system panel and Central Station. Compared to a dialup communication link, cellular can save significantly in annual telecommunication costs UL Listed as the Primary Communicator and Fire Slave Input for the XR1 50/XR550 in Fire Applications under ANSI/UL 864 Commercial Fire (Meets NFPA 72) Works on digital cellular data networks over a variety of carriers XR550FC with 263C Cellular Communicator DIGITAL CELLULAR FIRE COMMUNICATORS FEATURES 263C/263H enhances system security that conforms with NFPA and UL requirements Direct reporting to the DMP Central Station receiver, with no relaying of alarm signals Fire Slave Input option of the XR1 50/XR550 with 263C/263H approved for any FACP Modular solution means easily updated for newer technologies Eight-path redundancy with multiple message delivery available DMP Adaptive Technology1M switches communication paths while maintaining supervision if the current path becomes unavailable 263C/263H uses power from panel with low current draw for Long standby battery life Can be equipped with Local or remote antenna, offering more flexibility when installing Ability to check signal strength indication at the keypad Messaging features transmit alarms/alerts to users via SMS text messages, and allow users to remotely control their panel via text commands Intrusion t.Fire .Acce.ssI Network lCeltular . DIRECT REPORTING The digital cellular communicators transmit IP data packets directly from the panel's processor over the wireless data network. ALL of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response. with no concerns about signals not being properly relayed or intermediate communication links failing. ADD-ON TO XRI50/XR550 PANEL The 263C/263H works as an easy-to- install XR150/XR550 expansion card, with plug-and-play ease of installation. No extra programming is required. It provides full data delivery of DMP Zones. Areas, and Users, with all names and details included. The remarkably compact 263C/263H won't take up a lot of space in your communications closet. The unit directly installs in the panel expansion card slot, which is mounted inside a sturdy UL- listed metal cabinet. Tamper protection is also available for added security. UL LISTED Install the DMP 263C/263H Digital Cellular Communicator in an XR150/ XR550 Series panel to create a UL listed, primary communication path for commercial fire installations. The Fire Slave Input option of the XR550 has also been approved under ANSI! UL 864 (NFPA 72 2007 & 2010), allowing it to be used as a Slave Communicator for any FACP. 263H FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones, Areas. and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. EIGHT-PATH REDUNDANCY Feel more secure with up to eight paths of communication redundancy. Select from TCP, UDP, CDMA. HSPA+, Single Line Dialer, Dual Line Dialer with multiple IP numbers, and multiple telephone numbers. You identify and configure your redundant communication links via Remote Link. A DACT (digital alarm communicator transmitter) system may be configured as: Path 1 Type DD Primary and Path 2 Type DD Backup Path 1 Type DD Primary and Path 2 Type CELL Backup Path 1 Type DD Primary and Path 2 Type NET Backup A NET or CELL system may be configured as: Path 1 Type NET Primary with no Backup Path 1 Type CELL Primary with no Backup Path 1 Type NET Primary and Path 2 Type DD Backup Path 1 Type NET Primary and Path 2 Type CELL Backup Path 1 Type CELL Primary and Path 2 Type NET Backup ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable. Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. REDUCED EQUIPMENT NEEDS With other cellular backup equipment, you need to purchase additional enclosures, power supplies, batteries, cabling, and conduit connections. The 263C/263H reduces the number of pieces of equipment you have to purchase. It comes ready to mount, reducing your initial costs and simplifying both installation and ongoing operation. REDUCED COMMUNICATION COSTS Adding the cellular communicator to the DMP XR150/XR550 fire alarm control panel can lower costs significantly compared to dial-up connections. Fire systems typically require two dial-up lines that can be eliminated and replaced with a single cellular connection. SLAVE COMMUNICATORS XR150!XR550 panels operate as slave communicators via cellular communicaton in fire installations compatible with an FACP. In addition to standard hardwire slave communications that connect via inputs to the DMP panel, 1103 Wireless Transmitters can be installed to communicate FACP status. ANTENNA PLACEMENT The unit includes both local and remote SMA (S-band multiple access) antenna connections, giving you added freedom and flexibility during installation. LOW CURRENT DRAIN With its extremely low current drain and long standby battery Life, the 263C/263H will continue to provide a communications link for an extended period of time, even during a power failure. It draws half the current of other comparable units. SIMPLE TO INSTALL AND PROGRAM Connect the 263C or 263H to your panel. attach the antenna and power, and installation is complete. Programming the 263C/26314 is fast and simple, accomplished within the panel itself. After programming the 263C/263H cellular communications path via Remote Link, you will be presented with the Activate SIM/MEID window to activate your cellular plan. Once activated, the wireless backup connection is immediately online protecting your communications Link. No separate programming utility is required. SECURECOM CELLULAR SERVICES The 263H comes standard with a SIM (Subscriber Identity Module) card ready to use SecureCom Wireless Cellular Service from DMP. The 263C does not include a SIM Card and is activated with the MElD number. With the 263C/263H and SecureCom, you have a one-stop resource for both hardware and cellular service. ENHANCED FIRE PROTECTION Compared to dial-up connections, a digital cellular communication link provides greater reliability, protection from sabotage, and is less prone to being knocked out by weather. Unlike mobile cellular connections. the 263C/263H creates a fixed network connection that minimizes hand-offs and the chance for dropped connections. When trouble conditions occur, they can be more quickly diagnosed and often corrected remotely. The NFPA 72 code requires a test of the entire communications path every five minutes. The DMP Model XR150/ XR550 Panel used with DMP 263C/263H Digital Cellular Communicator meets this requirement when check-in and fail time settings are programmed for five minutes. The net result is a higher level of system reliability in comparison with traditional systems that rely on redundant phone lines and the substantially less frequent 24-hour supervision reports associated with that approach. UPDATEABLE In addition to being able to change cellular carriers, you will also be ready to take advantage of technical improvements as they occur. The unit's modular architecture enables seamless upgrades as improved technology becomes available. MOBILE PLATFORMS DMP mobile platforms provide you with the tools you need to build strong connections with your customers. MyAccessTM enables end users to monitor and manage their systems remotely from any mobile phone using simple SMS texting. The Virtual KeypadTM App puts a keypad on the user's Apple iPhone®, iPadTM. or Android compatible devices. Dealers can offer these much- appreciated services to their customers and realize the benefits of additional recurring revenue. MYACCESS Your customers can send many of the most common system commands to their residential or commercial systems via text messages. They can also choose to have alerts sent to them each time there's an arm/disarm, an alarm, or other selected events. Alerts can be transmitted by the panel as text messages to up to three phones. Users can also use MyAccess to interact with any Z-Wave devices programmed through their DMP panel, enabling them to control lights, thermostats, and more via text commands. Use any model of cell phone for Messaging Features SyI4bA,d THE VIRTUAL KEYPAD APP Dealers can invite their customers to begin using their APP to give them control of their security system. The Virtual Keypad allows them to arm or disarm, and to check the status of their cellular connected DMP security system from anywhere they have cell service. They can also access any Z-Wave home control devices programmed through their DMP panel and DMP cameras. Intrusion I Fire I Access I Network I Cellular ------------------------------------------------------------------------------------- .CDMA: :& -HS-PA- 1Cllu1r Corn municatOrs: DMP WIRELESS DEVICES FOR ANSI/UL 864 COMMERCIAL FIRE Complete your fire system with other DMP wireless devices that are ANSI/UL 864 Listed for Fire Protective Signaling Systems. TWO-WAY COMMUNICATION Superior to traditional wireless devices that just broadcast until the zone is restored. DMP 1100 Series require an acknowledgement from the 1100 Series Receiver, indicating successful communication. This smart technology ensures that each and every communication is received and efficiently processed at the panel. With the 900MHz frequency-hopping spread-spectrum technology, clear and accurate signal transmissions without interference in practically any environment is to be expected. 1100 SERIES RECEIVERS The 1100 Series Receivers: 1100X and 1100XH allow you to add up to 500 transmitters and is required for wireless capability in both regular and harsh environments. 1103 UNIVERSAL TRANSMITTER Model 1103 Universal Transmitter is typically used in commercial fire or burglary door/ window applications. It offers the same look and features as the 1101 transmitter, with the addition of a 470k end-of-line resistor and wall tamper switch. 1165/1165H/1165HS COMMERCIAL SMOKE DETECTORS The Model 1165 Smoke Detector, 1165H Smoke/Heat Detector, and 1165H5 Smoke! Heat Detector with Sounder include a tamper switch that j sends a trouble signal if the detector is removed from the mounting base. 1181 POST INDICATOR VALVE The model 1181 PIV is a weather proof and tamper resistant wireless switch for monitoring the open position of fire sprinkler control values of the post indicator, butterfly and other types. / 1182 OS&Y The 1182 OS&Y Switch is used to monitor the open position of an OS&Y (Outside Screw and Yoke) type gate valve. The 1182 mounts conveniently to most OS&Y valves ranging in size from /2" to 12". The switch operates the external contacts of the wireless transmitter when the valve position is altered from an open state. ACCESSORIES 270 Network Transient Suppressor 277 Trouble Annunciator 318 Battery Harness 381-2 18' Coax Extension 381-12 12' Coax Extension 381-25 25' Coax Extension 383 Rubber Duck Antenna 386 Wall Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna 387-25 SMA TO N CABLE, 25FE LMR1 95 387-50 SMATO N CABLE. 50FF, LMR195 866 Style W Notification Circuit Module 893A Dual Phone Line Module LISTINGS AND APPROVALS California State Fire Marshal (CSFM) Underwriters Laboratories (UL) Listed Underwriters Laboratories Canada (ULC) Listed SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (263C) Standby 13mA Alarm 13mA Current Draw (263H) Standby 24mA Alarm 28mA COMPATIBILITY DMP XR150 I XR350 I XR550 Series Panels (A 381 cable is required for the XR1 50 1 XR350 I XR550 Series) ORDERING INFORMATION 263C CDMA Cellular Communicator (Verizon) 263C/381-2 CDMA Cellular Communicator w/ 381-2 Cable (Verizon) 263H HSPA+ Cellular Communicator (AT&T. 1-Mobile. (263HCAN - Rogers)) 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T. T-Mobile. (263HCAN - Rogers)) For additional approval information, access www.dmp.com and - select Compliance. Intrusion I Fire Access I Network I Cellular 2500 North Partnership Boulevard 800.641.14282 I dmP.com Springfield. Missouri 65803-8877 Designed. Engineered & Assembled in Springfield. Missouri Solutions Expand your DMP panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, glassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 modules. 0 ©E x©: Za r ZONE EXPANSION EXPANSION MODULE FEATURES Provides Class B zones for burglary and fire Compatible with DMP Panels that allow zone expansion Suitable for mounting near protection devices Connect devices using 4-wire bus Easily mount attractive cases on wall or 3-gang box Compatible with all panel zone types Easy connection to 4-wire Keypad or LX-Bus Proven design ensures stability and performance Data LED on zone expander indicates good panel communication Durable and attractive plastic or metal housing Low current draw Can be powered from panel or auxiliary power supply ----------------------------------------------------------------------------------- USE ON THE DMP LX-BUSTMI. 708 BUS EXTENDER MODULES 710 The modules can be used on the LX-Bus The 708 Bus Extender Modules allow you As a splitter, the 710 provides superior of DMP Panels. The modules connect to to increase the length of wire used to run mechanical wire connecting capability the 4-wire bus and use only one zone an LX-Bus or keypad bus by a maximum of for up to three additional 12 VDC LX- address. To assign an additional zone 4,000 feet, while providing immunity to Bus or keypad bus circuits. This makes expander use the next available zone noise on the wires. The 708 Bus Extenders the 710 module an excellent junction address. are received from the factory as a pair of box when terminating multiple LX-Bus/ CONNECT TO KEYPAD BUS modules that connect between the panel keypad bus runs at one location. You can also use the modules as an and LX-Bus or keypad bus devices. As a repeater, the 710 module can be addressed device on the keypad data Use the 708 Modules for applications installed at the end of an LX-Bus or bus of DMP Command Processor panels. that include running wire over long keypad bus circuit to allow an additional Simply set the module to an available distances ' through noisy environments, circuit to be added, thus increasing the keypad address and connect the wiring or where the bus is bundled with other total wire length. wires such as telenhnne enmnnv wire to the appropriate screw terminals. The 708 Extender can be used on all DMP SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, and 715-16 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the covers go on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708 and 710 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1R Receivers. panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710 BUS SPLITTER! REPEATER MODULE The 710 Bus Splitter/Repeater Module allows you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710 Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, gtassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included 7141715 ZONE EXPANDERS 714-8,714-16,71 5-8, AND 714-8,714-16,715-8, AND The 714 contains four Class B burglary 715-16 DESCRIPTION 715-16 FEATURES zones and is suitable for use with burglary The expanders are housed in a Model 8 or 16 protection zones per and fire devices that are normally opened 340 locking metal enclosure suitable expander or normally closed. Individual zones are for mounting in a remote location. Durable metal enclosure housing supervised with 1k Ohm EOL resistors and Each expander provides screw terminal with lock and key can be programmed with any burglary or strips for zone inputs and data bus Individual screw terminals fire zone type. connections, a two position jumper to accommodate 14 to 22 gauge wire uesignae connection to the Keypad DUS for easy connection or the LX-Bus, and an LED to indicate • Suitable for mounting in a remote communication with the panel. Separate location zone End-of-Line resistors are included with each expander. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 7181 Plug-in Screw Terminal. The enclosure can also accommodate the 7191 Terminal Boards for the 714 or the 7201 Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 720T. ---.-.-. / 714/71 S FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-81714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8/715-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. ill DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire Keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. ill FEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing O&tt Mnftoring Prod.ct Module Address Number of Zones 3-HolePlastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC All DMP 12 VDC 710 N/A N/A Yes Yes 712-8 1 Dip Switch 8 Yes No 12 VDC XI Series and XR100/XR500 Series 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure MODULE SPECIFICATIONS 708 SPECIFICATIONS (NON-UL) Operating Voltage 8.8 to 15.0 VDC Operating Current 20mA Per Pair Dimensions 4.5" X 2.75" X 1.75". Maximum Distance 4,000 feet between the two 708 Modules 710 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 710 30mA Dimensions 4.5" X 2.75" X 1.75" Distance 2,500 feet (one module), 15,000 feet maximum 711 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current Average 11 mA + 1. 6mA per active zone Alarm 11 mA + 2mA per zone in alarm Zone Voltage 5 VDC (1.6mA across EOL) Dimensions 4.5" X 2.75" X 1.75" 712-8 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Current Draw 17mA + 1.6mA per active zone 17mA + 2mA per zone in alarm Dimensions 4.5" H x 2.5" W riT :::H Olgttot Monitor,ng Products 7141715 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714 Average 7mA+ 1.6mA per zone Alarm 7mA + 2mA per zone 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 7mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Dimensions 4.5" X 2.75" X 1.75" 714-8,714-16,71 S-8, AND 715-16 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714-8/16 Average 20mA + 1 .6mA per zone Alarm 20mA + 2mA per zone 715-8/16 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 20mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30m4 per smoke in alarm Enclosure 20-Gauge cold-rotted steel Dimensions 12.5" W 11.5" H x 3.5" D 714-8/-16 Color Gray 715-8/-16 Color Red LISTINGS AND APPROVALS Refer to the appropriate panel programming and installation guide for specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshall (CSFM) New York City (FDNY COA #6055) (711, 714, 715 only) Underwriters Laboratories (UL) Listed For additional information, access www.dmp.com and select Compliance. o — 9 — = 2500 North Partnership Boulevard 1 Springfield, Missouri 65803-8877 Contents ZONE EXPANSION MODULE FEATURES I USE ON THE DMP LX-BUSm 2 CONNECT TO KEYPAD BUS 2 SIMPLE ADDRESSING 2 EASY INSTALLATION 2 ZONE PROGRAMMING 2 708 BUS EXTENDER MODULES 2 710/710F BUS SPLITTER/REPEATER MODULES 2 712-8 ZONE EXPANSION MODULE 2 712-8 FEATURES 2 714/715 ZONE EXPANDERS 3 714-8, 714-16, 715-8,AND715-16 DESCRIPTION 3 725 24 VDC EXPANSIONMODULE 3 711 DESCRIPTION 3 711 FEATURES 3 ZONE EXPANSION MODULE COMPARISON CHART 4 MODULE SPECIFICATIONS 4 LISTINGS AND APPROVALS 4 ------------------------------------------------------------------------------------ 1 The Notification Modules from DMP provide superior supervision for changes in the state, such as ground faults, shorts, and opens. The modules activate 12 or 24 VDC, UL Listed, polarized notification devices, which alert on- site personnel of alarm, such as a fire or burglar alarm. The modules also provide Silence switches that allow technicians to disable the modules' bell output during service and maintenance checks. NOTIFICATION MODULE FEATURES Powered from panel or auxiliary power supply Suitable for use with 12 VDC or 24 VDC devices Supervised Silence Switch disables the bell output during service or maintenance Provide supervised Style W 2-wire circuit for notification appliances 865 FEATURES Provides one 4-wire circuit or two 2-wire circuits Provides Style Y, Z, W, or X notification circuit for the connection of appliances 866 FEATURES Supervises auxiliary power supply 867 FEATURES Works on XR200, XR200-485, and XR2400F panels Provides Steady, Pulse, Temporal Code 3, and California Schools Code bell outputs Provides supervision for opens, shorts, and ground fault conditions on the bell circuit On-board status LED indicates good panel communication On-board Power Supply Monitor LED indicates loss of power from an auxiliary power supply Easy rotary addressing; no difficult binary switches Ideal for mounting near notification devices Connects to 4-wire LX-Bus111 from the DMP panel Power supply monitor circuit causes an open (trouble) condition on the module's supervisory zone when power is Lost from an auxiliary power supply ---- • - - ------.- - ----------------------------------. INSTALLING THE. NOTIFICATION MODULES You can install the Notification Modules in any of the panel enclosure's 3-hole mounting locations using the plastic standoffs provided. NOTIFICATION APPLIANCES The 865, 866, and 867 Modules easily connect notification appliances, such as horns and strobes. By connecting the appliances in parallel, it is possible to connect several appliances to one module. Refer to the installation sheets for more information. AUXILIARY POWER SUPPLY You can connect a maximum 5 Amp, 12 or 24 VDC UL listed auxiliary power supply to the Notification Modules to support alarm power requirements beyond the panel's alarm output capacity. SILENCE SWITCH OPERATION The Silence switch on the Notification Modules allows technicians to test or perform maintenance on the DMP fire system without sounding the building's fire alarm notification devices. POWER SUPPLY SUPERVISION The panel can supervise the auxiliary power supply through the normally closed trouble contacts on the power supply that also connect to terminals 7 and 8 on the 866 and 867 Modules. When the bell circuit is in a bad condition, the modules indicate the bad condition to the panel. 867 DESCRIPTION The 867 connects to the panel's LX-Bus and provides one supervised Style W circuit, and four LEDs to indicate circuit Trouble and Ground Fault conditions. 867 ADDRESSING The 867 uses two pairs of rotary switches for setting the Bell Relay Address of the module and a Supervisory zone address. Having a separate Bell Relay Address allows multiple modules to be activated in groups and yet monitored by individual Supervisory zones. 867 BELL RING STYLE You can specify the bell output cadence on the 867 module by setting the Bell Ring Style jumper for Steady, Pulsed, Temporal Code 3, or California Schools. The 867 can then be activated by the Fire Bell output or by a Zone Alarm Output of the panels. MULTIPLE 866 MODULES You may install up to 25 Model 866 Style W Notification Modules on each XR200, XR200-485, or XR2400F panel by using the relay outputs available on the panel. ACCESSORIES 801 Piezoelectric Mini-horn 802 Multi-tone Notification Appliance 803 Horn Appliance 806 Motor Bell 821 Sync/Non-Sync Strobe 822 Sync/Non-Sync Strobe Plate 823 Horn/Strobe Appliance 831 Single Sync Module 832 Dual Sync Module 901 24 VDC Mini Horn 904 24 VDC Horn 906 24 VDC Bell 921 24 VDC Multi-Candela Strobe 922 24 VDC Multi-Candela Retrofit Strobe 923 24 VDC Multi-Candela Horn Strobe 924 24 VDC Multi-Candela Audible Strobe 502-12 2 Amps @ 12 VDC 502-80 80-Hour Standby Charger 504-24 4 Amps ® 24 VDC 505-12 5 Amps ®1ZVDC 508 8 Amps @ 12 or 24 VDC 865 DESCRIPTION 966 DESCRIPTION The 865 is suitable for use with 2 or 4- The 866 Notification Module provides one wire Style Y, Z, W, or X circuits, and 5 Amp Style W notification circuit for provides one Trouble and one Ground supervising UL listed, polarized Fault LED and a set of trouble contacts notification devices such as bells, strobes, to indicate off normal conditions. and horns. The 866 is compatible with DMP Command Processor panels. 865 SELECTABLE CIRCUIT STYLES By setting a jumper on the 865 Module, you may use Style W (2-wire) or Style X (4-wire) notification circuits for the connection of appliances. You may also use Style Y (2-wire) or Style Z (4-wire) circuits. This flexibility allows one module to be used in a variety of applications. 865 SPECIFICATIONS Operating Voltage 9.6 to 14.2 VDC from panel Operating Current Standby: 26 mA, Maximum: 85 mA Maximum Alarm Current 5 Amps @ up to 30 VDC Circuit Styles One 2-wire Style W or Y or One 4-wire Style X or Z 866 SPECIFICATIONS Operating Voltage 12 VDC Operating Current (from panel) Standby: 45 mA, Maximum: 75 mA Alarm Contact Rating 5 Amps at 24 VDC resistive Trouble Contact Rating 2 Amps at 30 VDC resistive 867 SPECIFICATIONS Operating Voltage LX-Bus: 8.0 to 15.0 VDC Bell Power: 10.2 to 28 VDC Operating Current LX-Bus: 30mA Maximum Bell Power: 30mA Standby, 80mA Maximum Alarm-Switching Current 5 Amps Form C Relay Rating 1 Amp at 24 VDC - .5 Amp at 120 VAC Switched Ground Rating 50mA maximum each output Module Dimensions 2.75" x 1.25" PANEL COMPATIBILITY The 866 and 865 Modules are compatible with all DMP Command Processor panels. The 867 is compatible with XR200, XR2400F, and XR200-485 Command Processor' Panels. L 0 0 [ 2500 North Partnership Boulevard Digital Monitoring Products [ I -8877 Springfield, Missouri 65803 LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 263H: Cellular Communicator *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver hOUR: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division July 8, 2004 DF-52301 • D-0251 FirelfferALarms www.firelite.com GENERAL The FCPS-24FS6 is a compact, cost-effective, 6-amp re- mote power supply with battery charger. The FCPS-24FS6 may be connected to any 12-or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expan- sion (to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. Operates as a sync follower or a sync generator (default). * See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. Four Class B (Style Y) orfour Class (Style Z) (with ZNAC- 4 Module) Notification Appliance Circuits. 6.0 A full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864). 4.0 A continuous output in stand-alone mode (UL 1481). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets UL power-limiting re- quirements. Form-C normally-closed trouble relay. Fully supervised power supply, battery and Notification Appliance Circuits. Selectable earth fault detection. FCPS-24FS6 24 Volt, 6Amp Remote Power Supply Section: Power Supplies/Accessories D California APPROVED 7315-0075:206 LISTED MEA S2424 219-02-E AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notifica- tion circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for appli- cations requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. FireLite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product IS09001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all _____________________ requirements. All specifications are subject to change without notice. I I For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. INGINFIRINS & MJINUFAZTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52301 07/08/04 - Page 1 of 2 STANDARDS and CODES The FCPS-24FS6 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Sys- tems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand-alone mode). SPECIFICATIONS Primary (AC) Power FCPS-24F56: 120 VAC 60 Hz, 3.2 A maximum Wire size: minimum 14 AWG (2.0 mm2) with 600V insu- lation. Control Input Circuit Trigger Input Voltage: 9.0 to 32 VDC. Trigger Current: 2.0 mA (16-32 V). (per input) 1.0 mA (9- 16 V). Trouble Contact Rating 5.0Aat24VDC. Auxiliary Power Output Specific Application Power - 500 mA maximum. OutputCircuits +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. 4.0 A maximum total continuous current for all outputs (Stand-alone mode). 6.0 A maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit Supports lead-acid batteries only. Float Charge Voltage: 27.6VDC. Maximum Charge Current: 1.5 A. Maximum Battery Capacity: 18AH. ORDERING INFORMATION FCPS-24F56 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions. FCPS-2456RB Replacement mother board PN 90286 FCPS-24F Module Mounting Kit ZNAC-4 Class A (Style Z) NAC option module A77-716B 12/24 VDC end-of-line relay for monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt, 7.0 AH (two required). APPLICATIONS Example I Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B (Style Y) outputs or 4 Class A (Style Z) outputs (using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24F56 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24F56 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 - DF-52301 07/08/04 Example 2 Use the FCPS-24F56 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS-24F56 inputs. Example 3 Use addressable control modules to activate the FCPS- 24F56 versus the FACP Notification Appliance Circuits. This typically allows for mounting the FCPS-24F56 at greater distances* away from the FACP while expanding system architecture in various applications. In this example, an addressable control module is used to activate the FCPS-24F56 and an addressable monitor module is used to sense FCPS-24F56 trouble conditions. Local auxiliary power output from the FCPS-24F56 pro- vides power to the addressable control module. *Fire.Lites MS-9200, MS-9200UD, (198-point) or MS-9600 (636- point) addressable FACPs have the capability of locating control and monitor modules up to 10,000 feet (3048 m) away. Sync Follower/Generator Note: In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power, which are created by a Fire Alarm Control Panel such as the Fire-Lite MS-9600. When installed at the end of a MS-9600 NAC wire run, this power supply can track (i.e. "follow") the strobe synchro- nization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the addi- tional strobes attached to this power supply. When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs track the strobe synchronization pulses present at this supply's sync input terminal. The pulses are originated from an upstream FACP or other power supply. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input terminal are not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTE 5EN5Ønt Photoelectric Smoke Detectors System Sensor's /3 series smoke detectors represE significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZWalk feature Built-in test switch Installation ease. The P line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with crywall anchors. To complete the installation, P heads plug in to the base with a simple Stop-Drop 'N Lock action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. Two-wire i3 dete:tors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the i3 protocoi. This signal is indicated by LEDs located at the module and the panel. The SENS-DR, a wireless device, displays the sensitivityof 3 detectors in terms of percent per-foot-obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & <~> " MEAMSFM LISTED approved approved S:fl, :IOi.'.m, p272 .CO][ 2O9 (j Smoke Detector Specifications Smoke detector shall be a System Sensor iC/cries model number listed to Underwriters Laboratories UL 268 for Fire Prorectri Signaling Sy5tems.1 he detector shall be a photoelectric type (Model 2W-B. 4W-P.) or a combination photoelectric/thermal (Model 2WT-B, 4WT-13) with thermal sensor rated at 135°F (57.2°C). The detector sl rat ir-cludo a I rrouritirrq base for mntmurr;ing to 3½-inch and 4-ir ich ota or ial, single gang, and 4-li ,,Ii square back boxes wril - a plaster ring, or direct mount to the ceiling using drywall archers. Wiring connections shall be made by means of C/MS screws. The detector shall ailow pre-wiring of the base arid srre head shall be a plum. in tvpcc The decimator shall have a nominal ser'dtrvrtv of 2.3 percJr'.t-pem-focmt nominal as measured in the lJL srTrc;kct box The detector shal decapable of auionmnr;icaily adjusting its serrsrtivrty cy mnearrs oldriit cor-iperisarieni arid sirmootlrr'cj algorirl;rns.Tlre detettor shall provide dual color LID indication which birrras to indicate oower up, rrerrnal standby, out ot serrsruvrtv, alarm, and fnceze trobie ttViodel 2W1-Lt, 4W-B) conditions. When used in conjunction with the 2W-M0D2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance atthe alarm control panel, arid shall provide a mop tcstkq canability to verily-he circuit svthout testing each detector irclrvidually. Operating Voltage No i inal: 12/24V norr-polanized Minimum: 8.5V Maxirniurrr: 35\/ Maximum Ripple Voltage 300/,- peak to peak of applied voltage Standby Current 2-wire: tOgA mexirrrurr average. 4-wire: 5150 p rnaxiiniumn e'cuigc Maximum Alarm Current 2-wire: 130 mA limited by corrtrol penner; 4-wire: 20 mA @l2V, 23m4@ 240 Peak Standby Current 2-wire: 100 pA; 4-wire: ri/a Alarm Contact Ratings 2-wire: ri/a-. 4-wire: 0.5 A @ 301J AC/D( Dimensions (including basal 5.3 inches r 12 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 cc. (128 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-120°F (0°C-19'C); 2%/-[-B and -IWT-B: 32'F- Operating Humidity Range 0 to 95% R non-condensing Thermal Sensor T3 SF (57.2°C) Oxed FreezeTrouble 2WT-B and 4VV 1-B only: 41°F (5°C) Sensitivity 25%/ft. nominal Input Terminals 14-22 AWU Mounting 3'-/2-inch octagona back box 4-inch octagorral back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling -- __-- -'-__ LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every ID seconds Initial LLD sta:os indication 80 seconds Normal (standby) Blink every S seconds off Out of sensitivity off Bunk every 5 seconds Freeze trouble off Bunk every 10 seconds Alafrin off Solid Ordering Information --- - - - 2W-B No 2-wife 130 MA max. iimniled by control panel 2WI-B Yes 2-w:re 130 mA max. united by control panel 4W-B No 4-wire 20 inA % 12V, 231rrA yIn 24V 4WT B Yes 4-wire 20 rrrA @ 120, 231nA ye 2451 Accessories 2W-M0D2 2-wire loop tess/irrainternance module RI Removal! replacement too! SLNS-RDR Seirs.irvrtv reader A77-AB2 Retmoflt adapter bracket, 6.6 in. (I 6.76cm) diamnretem 3825 Ohio Avenue St. Charles, Ic 60174 n 5 J5OR Phone: 800-SENSOg) Fax:630-371-5495 "' LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 2W-B, 2W1-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4W1-B are 4-wire detectors. Models 2W1-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Srnp!e operation 'kes instant -m The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-plated contacts to avoid the risk of corrosion FEATURES Approvals: UL and CSFM Americans with Disabilities Act (ADA) compliant Die-cast metal construction Reset key Mounts on standard single-gang box Optional surface and weatherproof backboxes available High-gloss red enamel finish Scored acrylic breakrod DiSC R P1710 The DMP 850 Series Fire Alarm Pull Station is a high quality, die-cast metal manual pull station available in either single-action or dual-action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 Amp ® 30 VDC. The contacts are gold-plated to avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COXPUAtCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. A variety of mounting options are available for the 850 series. It can be flush mounted to a standard single gang switch box or surface mounted in two optional configurations. The Model 850-SB Interior Surface Backbox or the Model 850-WP Weatherproof Backbox both allow conduit connection to the 850 Series Pull Stations. 850S OPER?T! The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. 8OD ORAT! On the Model 8500 Dual Action Pull Station, the push bar rotates inward allowing the PULL handle to be grasped in a one handed motion. To create an addressable reporting zone for the 850 Series, install a Model 711 Zone Expansion module. PULL Screw Terminals To next To Fire Alarm EOL resistor device or Control Panel Model 850 Wiring Diagram SC:CATt:S OR 1G : 1ATO Switch Rating 1 Amp @ 30 VDC 850S Single-action pull station - Dimensions 4.75" H x 3.25" W x 2.25" D 8500 Dual-action pull station Color Red w/raised white letters, white 850-SB Interior surface sheetmetat backbox 10 PULL handle w/raised red letters 850-WP Weatherproof surface die-cast backbox = 850-AR Scored acrylic breakrods (1 dozen) , The 850 Series Fire Pull Station is compatible with all 850S/711 Single-action pull station w/addressable module DMP Command Processors. 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. . .b 2500 North Partnership Boulevard 1 Digital Monitoring Podct Springfield, Missouri 658038877 j I LISTING No. 7150-1157:0112 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models 850D (key lock, push bar) and 850S (key lock, no push bar) noncoded manual pull stations. Suitable for outdoor use when installed with Model 850-WP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Rev 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division .. SYSTE 5FN5 Selectable Output Horns, Strobes, and Horn/Strobes SpectrA iert Advance selectable- output horns, strobes, and horntctrobes are rich with features guaranteed to cut installation times and maximize profits. SPECTReIt The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate so a four-inch square, four-inch octagon or double-gang junction box.The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are ratec between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features Electrically compatible with existing SpectrAlert products Automatic selection o 12- or.' 4-volt operation at 15 and 15/75 candela Plug-in design Field selectable candela setngs on wall and ceiling units: 15, 15/75, 30, 75, 95,110,115,133,150,177,185 Same mounting plate for wall- und ceiling-mount units Shorting spring on mcunting aate for continuity check before installation Tamper resistant cons:ruc:ion Outdoor wall and ceiling prod-i.:ts ra:ed horn —40"F to 151'F Design allows minimal int,usic:r into the back box Horn rated at 88+ dbA at vol, Rotary switch for horn tone and three volume selections Outdoor products UL listed to JL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof perUL 50 (NEMA 3R) Compatible with MDL sync mccule Agency Listings SIENAUIIO ®4>MEA. approved LISTED APPROVED SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 1½-inch hack box, 4-inch octagon back box or double-gang back box Two -wire products shill also mount o a single-gang 2 x 4x nch nick box A uni e sil i a. in no plate ih be used or mounting 'no errS p and vii products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlort Advance products, when used with the Sync.Circuf Module accessory, shall he powered from a non-coded notification appliance circuit output end shall operate on a nominal 12 or 24 volts, When used with the Sync-Circuit Module, 12-vo:7 raced notification appliance circuit outputs shall operate between nine and 11.5 volts; 24-volt rated nocificabon appliance crrcurt outputs shall operate between 17 and 33 volts, indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered cower supply. Strobes and horn/strobes shall have field-selectable candela settings including 15. 15/75.30, 75,95,110,115,135,50,117,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for lire protect;ve service, the strobe shal be wired as a orimary-signaling notification appliance and comply teeth the Americans with Disabilities Act requirements for visible sign-Jung appliances, flashing at 1Hz over the strobe's entire operating voltage ranae.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shaH bee System Sensor SpecrrAiert Advance Model listed to UL 1971 and Uk 464 and shl: he approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and ccrnpiy with the Americans with Disabilities Act requirements for visib'e signaling appliances, Pealing at 1Hz over the strobe's entire operating voltage ranqe.'I he strobe light shall consist of a xenon flash tube and associated lens/reflector systern.The horn shall have three audibility options and an option to s'wircli between a temporal three-paiteru and a non- temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe mode-Is shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by DL and shall operate between minus 40 degrees and 151 degrees Fahreneit.i'he products shall he listed br use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit nrodel MDL listed to UL 464 a...d shall be approved for fireprotective service.-me module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module sheil silence the horns on horn/strobe models over a single pair of wires. The module shah mount o a 4Ths x4t/ x 2'/s-inch back bcx. The modulesliall also control two StyleY (class B) circuits or one Style 7 (class A) circuit. 't'fre module shall synchn rnize multiple zones. Daisy chaining two or more synchronization r'rroclules together will synchronize all the zones they control.1 he module shall not operate one coded power supply. Standard Operating Temperature 32"F to 120T (0°C to 49°C) K Series Operating Temperature -40°f tot 51°F (-40°C to 66"C.) Humidity Range 10to93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Requated 12DC/FWR or tequlate.d 24D(JFWRt Operating Voltage Range' Ste 17.5 V It 2V nornirrall or 16 to 33 \' (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8' diameter x 2.5' high 1173 rr'rrrr diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 41W 2.5D (142 rrrrrt Lx 119 inm W x 64 rrrm Dl Horn dimensions 5.61 x 4.7W xi .3T) (142 tern Lx 119 mrrr W x 33 rra-rr Dl Wall-mount back box skirt dimensions (DOS 2, BBSW-2) 5/I1 x 0•W x 2.2D 1151 ITIn, Lx 128 mm W x 56 TIm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2( 7 diameter x 2.25 high (180 mrnr diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB( 5.7k x 5.1W x 2.03) (145 mm Lx 130mm Wx St 1'nm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 1.1" diameter x 2.0' high If 180 mn diameter x 51 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some poever supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15//51 ccl. Temporal Medijm 44 49 58 69 temporal Low 38 44 '14 48 Nun-temporal Mqh 57 56 69 75 Non-temporal Medbr '12 50 60 69 Non-temporal Low 4 1 44 50 50 Coded I Ugh 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 Candela Range 15/75* 142 148 77 81 390 NA NA 94 96 7Y NA NA 158 153 95* NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range io NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 lbrnporalHiah 137 147 79 90 107 176 194 212 218 Temporal Medium 132 111 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporaiHigh 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 158 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 205 Temporal Low 129 151 76 86 101 150 184 194 201 Non-temporal 1-ligh 142 151 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 215 Non-temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-tempoial High 255 270 303 309 Non-temporal High 233 248 275 231 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating ratings must be reduced in accordance with this table. - I 1 For K series products used at low temperatures, listed candela Horn Tones and Sound Output Data 8-175 16-33 Switch Volts Volts Position Sound Pattern dB DC FWR CC FWR 24 Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 915 3 Temporal Low 71 73 7676 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 tOO 5 Non-temporal Medium 78 /8 85 85 90 90 98 98 6 Non-temporal Low 75 75 8' $1 $8 84 95 92 7 Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 91 Coded Low 75 75 Si 81 88 85 96 92 'Settings 7,8. and Oar: not available on 2-wire horn/strobe. Listed Candela Candela rating at _40*F 15 Do not use below 328 15/75 30 75 4-I 95 70 ItO 110 115 115 135 135 150 150 177 177 185 185 SDectrAlert Advance Dimensions Ceiling-mount horn/strobes 5•® .• Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information -__i _ _77-77-7-1 Wall Horn/Strobes Ceiling Horn/Strobes (contd.) P2R 2-wire 1-lorn/Strobe, Standard cd, Red PC2W 2-wire Horn/Strobe, Standard cd, White P2R1 H' 2-wire l-Iorn/S:robe, High cd, Red PC; WW_ 2-wire Horn/Strobe, i kgb cd, WI ke P2RK 2-wire I Iorr'/Strebe, Standard cd, Red, (Outdoor PC4R a-wire torn/Strobe, Standard cd, Red P281 K 2-wire I lorn/Strebe, I ligh cd, Red, Outdoor PC4RH 4-wire Horn/Strobe, '-Ugh cd, Red P2W 2-wire Horn/Strobe, Standard cd, White PC4RK 2-wire Horn/Strobe, Standard cd. Red, Outdoor P2WH 2-wire i-lorn/Strobe. High cd, White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P41R 4-wire Horn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd, White P4RIH' 4-wire Horn/Strobe, High r.d, Red PC4WH 4wire Horn/Strobe, High cd,White PURK 4-wire 1-lorn/Strehe, Standard cd, Red, Outdoor Ceiling Strobes P4RI-IK 4-wire Horn/Strobe, I-ugh cd, Red, Outdoor SCR Strobe. Standard cd, Red P4W 4-wire Horn/Strobe, Standard cd, White SCRH Strobe. High cd, Red l>4WH 4-wire Horn/Strobe, High cd, White SCRK Strobe. Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe. lligh cd. Red, Outdoor SR' Strobe, Standard cd. Red SCW Strobe, Standard cd, White SRI H" Strobe, High cd, Red SCWH Strobe. High cd, V/bite 58K Strobe, Stancrrrd cd. Red, Outdoo' Horns SRHI( Strobe, High cd, Red, Outdoor HR I-Her, Red SW.Strobe, Standtr-d cd. White HRK I'iorr, Red, Outdoor SWH* Strobe, I ligh cd, White 10 Herr, White Ceiling Horn/Strobes Accessories PC2R 2-wire Horn/Strobe, Standard cd, Red IUBS-2 Back Box Skirt, V/al., Red PC2RI-H' 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, WaI,Wnite PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red PC281 1K 2-wire I 1cm/Strobe, I ugh cd, Red, Outdoor BBSCW-2 Back Box Skirt, Ceiling, White Notes: Add"-Pro model number for plain housing (no "FIRE"marking on cover), e.g., P2R-P Add "-SP'to model number for"FUEGO"markioo on cover, e.g., 112R-SP k"Staodard cd; refers to strobes that include i, 12/72,30, 75,95, 110. and 115 candela settings."High cd,' refers to strobes that include 135, 150. 177, and 185 candela settinos. All outdoor units ending in' K"include a weatherproof back box. L4it,/LI 3823 Ohio Avenue. St. Charles, iL20i7'i .$ SJSOR Phone: 800-Si' NSOR2 Fax: 630-3!/-b495 LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Lin hart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -P0, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177, *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to + 151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division