Loading...
HomeMy WebLinkAbout2714 LOKER AVE W; ; FPC2016-0007; PermitPERMIT REPORT (7city of Carlsbad Print Date: 12/06/2021 Job Address: 2714 LOKER AV WEST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090813200 Track #: Valuation: $609,881.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: VERTIFLEX - TI TO INSTALL (RELOCATE) 45 SPRINKLER HEADS TI - INDUST VERTIFLEX: 13,322 SF TI AT 1ST & 2ND FLOOR - OFFICE TO OFFICE Permit No: FPC2016-0007 Status: Closed - Finaled Applied: 11/15/2016 Issued: 11/18/2016 Finaled Close Out: 01/11/2021 Inspector: Final Inspection: Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAZZMIN DEEKEN 9925 PROSPECT AVE. #STE B 9925 PROSPECT AVE, #B SANTEE, CA 92071 SANTEE, CA 92071 (619) 562-3010 (619) 562-3010 FEE AMOUNT Fire Inspection Fee Manual $71.00 Fire Protection Sys Manual $157.50 Total Fees: $228.50 Total Payments To Date: $228.50 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tqcci Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-FRL - 2.8,y 5.6., and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard cover- age, solder type spray sprinklers de- signed for use in light and ordinary hazard commercial occupancies such as banks, hotels, shopping malls, schools, hospitals, etc. The recessed version of the 2.8 and 5.6 K-factor, Series TY-FRL Pendent Sprinkler, where applicable, is intend- ed for use in areas with a finished ceil- ing. It uses a two-piece Style 20 (1/2 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total ad- justment from the flush pen dent position. The adjustment provid- ed by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. An intermediate level version of the 5.6 and 8.0 K-factor, Series TY-FRL Pendent Sprinkler can be obtained by utilizing the Series TY-FRL Pen- dent Sprinkler in combination with the Model S4 Shield. The Series TY-FRL Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or sprinkler manufacturer with any questions. Sprinkler Identification Numbers TY1121 ...... Upright 2.8K, 1/2"NPT 1Y1221 .... Pendent 2.8K, 1/2"NPT TY3121 .....Upright 5.6K, 1/2"NPT TY3221 .... Pendent 5.6K, 1/2"NPT TY4121......Upright 8.0K, 3/4"NPT TY4221 .... Pendent 8.0K, 3/4"NPT TY1121 is a redesignation for S1879 and G8973. TY1221 is a redesignation for S1880 and G8971. TY3121 is a redesignation for S1864 and G8974. TY3221 is a redesignation for S1865 and G8972. TY4121 is a redesignat'' and G8174. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 TY4221 is a redesigns and G8172. FPC20I 6-0007 2714 LOKER AV WEST OCTOBER 2013 TFPI3O 1 - Frame 5 - Link 2 - Strut Assembly 3 - Deflector 6 - Ejection 4 - Hook Spring WRENCH AREA .1 TFPI3O Page 2 of 6 5 STYLE 20 RECESSED _ (ESCUTCHEON DEFLECTOR* 2-7/8" (73,0 mm) DIA. * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING DEFLECTOR * SURFACE 2-11/16" (68,3 mm) 2" (50,8 mm) 7 - Button 8 - Seal 9 - Bushing 1 2-11/16 (68,3 mr 7/16 (11,1 mm) NOMINAL MAKE-IN 1/2 NPT** WRENCH FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TVII2I) AND PENDENT (TY1221) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector, special request. PLATE SATING WRENC AREP RECESSEI ESCUTCHEI DEFLECTOR * 2- STYLE 2C 7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT' CROSS SECTION' FIGURE 2 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY3121) AND PENDENT (TY3221) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT DEFLECTOR * \ 2-11/16 \ (68,3 mr 7/16" I (11,1 mm) I NOMINAL ) MAKE-IN SURFACE T(68, 2-11/16" 3 mm) 2" (50,8 mm) 1 - Frame 5 - Link 7 - Button 2 - Strut Assembly 8 - Seal 3 - Deflector* 6 - Ejection 4 - Hook Spring 1/2' NPT** I WRENCH FLANGES UPRIGHT TFPI3O Page 3 of 6 DEFLECTOR * CEILING PLATE 1 - Frame 6 - Ejection SEATING SURFACE 2 - Strut Spring 3 - Deflector 7 - Button 4-Hook 8-Seal _______ // WRENCH 1 - Link 2-1 3/16" _________ Assembly ________ ______ AREA (71,4 mm) 2-15/16" _______ * 6 7 Temperature rating is 1/2" _____ indicated on Deflector. (12,7 mm) NOMINAL I provided on special (74,6 mm) 2-3/16" ** Pipe thread connections I j per ISO 7-1 can be MAKE-IN (55,6 mm) request. 3/4 NPT** WRENCH DEFLECTOR FLANGES UPRIGHT PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY4121) AND PENDENT (TY4221) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, NYC, and LPCB Approved. (Refer to Table A for complete approval information includ- ing corrosion resistant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi1'2 (115,2 LPM/bar1'2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame .......................Bronze Strut .........................Monel Deflector.....................Bronze Hook.........................Monel Link Assembly .................Nickel Ejection Spring................Inconel Button.......................Bronze Seal .......................TEFLON Bushing (2.8K only) .............Brass Operation The fusible link (heat collector) assem- bly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprinkler to operate. Design Criteria The TYCO Series TY-FRL Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard instal- lation rules recognized by the appli- cable Listing or Approval agency (e.g., UL Listing is based on the require- ments of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRL Sprinklers must be installed in accordance with this section. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft./lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft./Ibs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRL Pendent and Upright Sprinkler Installation The Series TY-FRL Pendent and Up- right Sprinklers must be installed in accordance with this section. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 6). With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. TFPI3O Page 4 of 6 Series TY-FRL Recessed Pendent Sprinkler Installation The Series TY-FRL Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 12 Recessed Sprinkler Wrench (Ref. Figure 7). With reference to Figure 1, or 2, the W-Type 12 Recessed Sprin- kler Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Escutch- eon over the Series TY-FRL Sprinkler and push the Escutcheon over the Mounting Plate until its flange comes in contact with the ceiling. SPRINKLER FINISH K TYPE TEMP. RATING FRAME COLOR NATURAL BRASS CHROME PLATED CODE PENDENT 165°F (74°C) Unpainted 212°F (100°C) White (TY1221) UPRIGHT 165°F (74°C) Unpainted 2.8 NPT 212°F (1 00°C) White RECESSED PENDENT 165°F (74°C) Unpainted - (TY1221 wlStyle 20) 212°F (100°C) White PENDENT 165°F (74°C) Unpainted 1,2, 3,4, 5 212°F (100°C) White 1,2, 3, 5 (TY3221) 5.6 NPT UPRIGHT UPRIGHT (TY3121) 165°F (74°C) Unpainted 1, 2, 3, 4, 5 212°F (100°C) White 1, 2, 3, 5 - RECESSED PENDENT (TY3221 w/Style 20) 165°F (74°C) Unpainted 1,2,5 212°F (100°C) White PENDENT 165°F (74°C) Unpainted 212°F (100°C) White 8.0 3/4" NPT (TY4221) 1,2,3,5 UPRIGHT 165°F (74°C) Unpainted 212°F (100°C) White - (TY4121) NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/03) as Quick Response Sprinklers. Approved by the City of New York under MEA 112-04-E. TABLE A LABORATORY LISTINGS AND APPROVALS TFPI3O Page 5 of 6 1/2±1/8 • 2-7/8 DIA. 1/2 (12,7 mm) (1 2,7±3,2 mm) (73,0 mm) 1/4 (6,4 mm) I FACE OF 2-1/4 DIA. MOUNTING PLATE I SPRINKLER 57,2mm 1/8" FITTING T-7-- MOUNTING SURFACE / t I 1-3/4' (44,5 mm) 1-1/2' (38,1 mm) CLOSURE TY-FRL FIGURE 4 SERIES TY-FRL (TY1221) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 1/2±1/8' 2-7/8" DIA. 1/2' (12,7 mm) (12,7±3,2 mm) I (73,0 mm) 1/4" (6,4 mm) I FACE OF 2-1/4' DIA. MOUNTING I SPRINKLER (57,2 mm) PLATE 1/8' FITTING -I \UC. I - _ I MOUNTING SURFACE 1-3/4" (44,5 mm) 1-1/2" (38,1 mm) CLOSURE TY-FRL FIGURE 5 SERIES TY-FRL (TY3221) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT WRENCH RECESS FIGURE 6 W-TYPE 9 SPRINKLER WRENCH WRENCH RECESS T t PUSH WRENCH UP TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 W-TYPE 12 RECESSED SPRINKLER WRENCH Care and Maintenance The TYCO Series TY-FRL Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. TPFI3O Page 6 of 6 P/N 58-XXX-)-XXX _j_ SIN 973 2.8K UPRIGHT (1/2"NPT) TY1121 981 2.SK PENDENT (1/2°NPT) TY1221 974 5.6K UPRIGHT (1/2"NPT) TY3121 982 5.6K PENDENT (1/2'NPT) TY3221 174 8.0K UPRIGHT (3/4"NPT) TY4121 172 8.0K PENDENT (3/4°NPT) TY4221 SPRINKLER TEMPERATURE RATING NATURAL BRASS 165 165°F (74°C) CHROME PLATED 212 212°F (100°C) TABLE B SERIES TY-FRL PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (PIN). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRL (specify SIN), (specify K-factor), (specify Up- right, Pendent, or Recessed Pendent) Sprinkler Quick Response, (specify) temperature rating, (specify type of finish), P/N (specify from Table B) Recessed Escutcheon Specify: Style 20 Recessed Es- cutcheon .with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 12 Sprinkler Wrench, P/N 56-798-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqcn Fire Protection Products Worldwide Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16" 1-7 mm) NOMINAL ______ (50,8 mm) cv " MAKE-IN _____ 1-3/8" 2" (50,8 mm) WF _________ (34,9 mm) Fl 1/2 NPT** DEFLECTOR* 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR,1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air babble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) - 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING (9,5±7,9 mm) (I 5/8' (15,9 mm) _______ —1 ___________ ____________ FLUSH 3/8±5/16' I MOUNTING \ 1/8 J I SURFACE (3,2 MM) 32mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4" \ 6,4 mm) 1/2(12,7mm) (7,9± FLUSH J I MOUNTING 1/8' SURFACE/ \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8"(34,9mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TEMPERATURE RATINGS 135 135-F (57-C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TFPI72 Page 4 of 4 P/N* 77 - XXX - X - XXX I I ____ _ ± SPRINKLER FINISH SIN 1 NATURAL BRASS PURE WHITE (RAL9010)** 370 5.6K UPRIGHT (1/2" NPT) TY313 POLYESTER 4 SIGNAL WHITE (RAL9003) 371 5.6K PENDENT (1/2" NPT) TY323 POLYESTER * Use suffix "1" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only TABLE A SERIES TV-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and Conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specifyt) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqca TEFLON is trademark of The DuPont Corporation. Fire Protection Products I Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ____________ Pressure Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar -200 to 1500 -28.90 to 300 65.60 20.7 500 34.5 600 41.4 2000 9330 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 165 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 550° 287.80 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®us APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ -Sizes '/,"-1" 0725 mm) Sizes 11/4"-2" (32-51 mm) Sizes 21/2 3" (64-76 mm) (°F) (°C) psi bar psi bar psi bar psi bar 200 to 1500 -28.9° to 300 20.7 2,000 65.60 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 5500 287.8 - - 300 20.7 300 20.7 1 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME 616.3 and Unions conformto ASME B16.39. ALL ELBOWS & TEES 3/ (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) www.anvilintl.com 17J I .5 4 fr i J l ;1'tit1icTALLDD;uii lit ka ~a 4 - At U t øit: 1;2 54 c®us LISTED <> APPROVED Do 4 NFPA 2 L1 1J Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com SCHEDULE 10 sales@bullmoosetube.com SCHEDULE 40 800.325.4467 EDDYTHREAD 40 EDDYLITE EDDY FLOW Ad BULL MOOSE TUBE CDIVIRANV Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. LISTED APPROVED 1] A FSA A,,.e,iean Fl,. NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill railings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schdiile 10 and Schedule 40: FM approved dnd UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadble with standard outside diameter. Eddy Flow®; Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard It® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. c®us LISTED APPROVED []4 NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 1527 141 lbs/ft 1.820 91 .91 1 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61' Lii LTTiTi fl2MIbsJWl fiT 1 2-1/2 2.875 2.635 - 4.92 - 3.53 lbs/ft 5.893 30 fl 3260 1 - - 19 4 4.500 4.260 250 5621bs/ft 111.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2055 70 L io0 E]{ j 11/2 1 1900 1610 100L2i?JOff— 3602 44 2375 7_ _IL [ 10P_ ]L 366lft]L 5.114 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 H 30 - TIC TET5TiLi 1.00 1 F_L!~8LftT E'TIE 12 4* 4.500 4.026 1.00 10.80 lbs/ft i 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com - Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road ) Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, Pt Masury, OH BULL MDOSE1UOE COIVIRAP,W 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. 11111 FireLock® Outlet-T STYLE 922 K3 ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 922 Outlet-I provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWN ER CONTRACTOR ENGINEER System No, Submitted By Spec Sect Para__________ Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV ( j4'tauiic 10.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I 1 1/4 ½ 11/16 1.30 1.83 1.10 3.87 2.56 1.0 32 \X 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 34 13A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 325 46.5 279 98.3 65.0 OR 1 1 /6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 ½ 1,5o 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 /16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65,0 0.59 2 ½ 13A6 1.66 2.19 1.46 4.60 2.56 1.3 x 50 15 30.2 422 55.6 37.1 116.8 65.0 059 3/4 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 302 41.7 55.6 37.1 116.8 65.0 064 1 13A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 1 37.1 116.8 65.0 0.68 2½ ½ 1/i6 1.91 2.44 1.71 5.40 2.56 1.6 x 65 15 30.2 48.5 62.0 434 137.2 65.0 0.73 3/4 1/6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 . 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 13A 1.91 2.44 1.71 5.50 2.56 1.6 761 mm x 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1/I6 1.89 2.44 1,71 5.50 2.56 1.6 20 30.2 480 62.0 .L 139.7 -65.0 1 0.73 1 1 3A6 2.13 2.79 J 1.71 5.50 2.56 1.7 25 30.2 1 54.1 70.9 L 43.4 1 139.7 65.0 0.80 STYLE 922 DIMENSIONS Ii'LJ.I NMI .If U t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problem9or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VIcTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 2 \4taulic RFV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-T STYLE 922 PERFORMANCE p' . Run Size li(himm vt4v'r' x Outlet Size I Equivalent Length of 1 inch. Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT F,iiters 8.5 2.6 83 2.6 La.iiiiii 25 Hazen-Williams coefficient of friction is 120 www.victaulic.com A-0 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. taul.c PFV ( 1fl52 3 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com \JtauIic' 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vICTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 FCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC 1/2 & 3/4 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - `@ us USTED 203-EX 2551 1"- 8" 4S> Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 131), these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WT. 5 WT.+250 UL TEST LOAD 1 3/8 3075 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 5415 520.75 750 2 3/8 76.95 21/2 3/8 118.35 841.75 3 3/8 162.30 1 634.75P 265500 1061.50 4 3/8 246.00 1480.00 5 1/2 349,45 1996.75 6 1/2 476.35 2631.75 8 1/2 1 711.00 1 3805.00 1 4050 Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. S.. Specific ,4FCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting ins listed sway brace, restrainer or banger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFC'ON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or prohit, when non-AFCON products have been, or are used. 1/08 Not east an 2 nominal width Wood Flooring .4 C UrOuUC( uea(UreS ___________ __________ _________ ________ No pre-drilling required. Not less than I Quick to install using the Sammy I'I Ynominal Jj Nut Driver with an 18V cordless thickness 2-1I7l (depth or aide ,,, Wood Joist I I drill/driver. I / of vertical member) - - -- Saves time from traditional / Double Sheetrock methods. Ceiling r Reduces installation cost. Made in the U.S.A. I -•.•2 1/4' 8002957 GST 100 1/4x1 210 (7/16 OS B) 670 (3/4" Ply) 25 125 1/4" 8003957 GST 200 1/40 2' 1760 (Fir) 25 125 1/4 8004957 GST 300 1/4x3 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4 Ply) 25 125 [_ 3/8 8007957 GST 10 1/40 1' 300 25 125 670 3/8"8008957 GST 2O 1/4x2' 1760 (Fir) 850 147525125 3/8__8068925 GST 2OSS1/402__1760 (Fir ) 850 25 1 3/8__8009925 GST 25-380 3/8x2-1/2"2113(Fir)1500 25125 3/8__8010957 GST 3O1/4x3__2060 () 15001475 25125 J 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 I_L8"_8011925GST401/4x4_2180 (Fir) 3/8" 8012925 GST 60 1/4o6" 2230 (Fir) 25 125 - I 1/2" 8013925 GST2 1/4x2" 1760 (Fir) _25 12 1/2' 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2"8015925 GST 3 1/4x3"2275(Fir) 25125 1/2" 8016925 GST 4 1/4 x 4" 2180(Fir) 25125 L_ 1/28017925 GST6 1/4n6 2230 (Fir) 25 125 1A #14 Black Nut Driver Part #8113910 #14 SW Red Nut Driver Pad # 8114910 11 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 Y2" / x 12 pitch roof. • Reduces installation cost. Allows 17" deflection from vertical. • Made in the U.S.A. 11illD Q . . _ ' L _38 .. 7SGSL01L2"_ - 1257(Fc) 1050 1475 25 125 12J 3/8" 8141957 SH-GST30 1/4x3' 1720 (Fir) 1500 1475 25 125 1#14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature Which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I' I I Not less than 2" nominal width / - - Product Features (1-1/2') up to 3-1/2" pipe: not less than • - _________ No pre-drilling required. 3' (2-1/2') nominal width 4" & 5" pipe - Floor Joist Quick to install using the Sammy Minimum 2-1/2' from bottom for Nut Driver with an 18V cordless branch lines. Minimum 3" from / bottom for mainlines. Exception: This - .1 drill/driver. / requirement shall not apply to 2" or 1/ - thicker nailing ships resting on top of Saves time from traditional steel beams. methods. Reduces installation cost Ii ._..,.- ----_ Made in the U.S.A. #14 SW Red Nut Driver Part #8114910 um em . Min M= M3 c] 1/4" 8018957 SWG 100 1/4x1 622 )Ffr( 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8"8020957 SWG 10 1/4 x1'622(Fir) 300 25 125 3/8__8021957 SWG 20 1/4 x 2" 1725(Fir) 1050 25 125 YL _3/8__8073925 SWG 20_SS 1/4x2_1725 ()850 25 1251 3/8' 8022925 SWG 25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4x3" 1884 (Fir) 25 125 1 FINSTALLATION STEPS .!Ali1I INTO WOOD & STEEL:] NSTALLATI0N STEPS .1 INTO WOOD & STEELI I "S. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the 414 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.