HomeMy WebLinkAbout2731 LOKER AVE W; ; FPC2019-0277; PermitPERMIT REPORT (city of Carlsbad Print Date: 12/02/2020 Permit No: FPC2019-0277 Job Address: 2731 LOKER AVE W, CARLSBAD, CA 92010-6601 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090812000 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 12/12/2019 Issued: 01/06/2020 Finaled Close Out: 02/11/2020 Inspector: Final Inspection: Project Title: Description: PROVIDIEN INJECTION MOLDING -NEW SPRINKLER MONITORING SYSTEM Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DO NOT USE MALCOLM DCOSTA 3870 MURPHY CANYON RD, # 140 3870 MURPHY CANYON RD, # 160 SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (619) 805-5300 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fpc 20019 OZ7 HIGHLIGHTED SETI Cut Sheets and CSFM Listing Sheets For: Providien Injection Molding 2731 Loker Avenue West Carlsbad, California 92010 Installer: Johnson 4 01(i Controls 11 -q r----- t 01 /ntegrated Security 3870 MURPHY CANYON ROAD SUITE 140 SAN DIEGO, CA. 92123 (800) 289-2647 LIC #977249 (C-b, C-7) DF-52416:D • A3-20 MS-5UD(E)IMS-1 OUD(E) Series) cj FireLiTeALarms (Five Zone Fire Alarm Control Pa Ten Zone Fire Alarm Control Panel by Honeywell Control/Communicators The MS-51JID-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-I0UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) iDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-1OUD-7 -ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-10UD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-10UD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A © 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-1OUD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D•07/2612010—Page 1 0f4 USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 Hz, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 Hz, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Top ' " " S Depth= 5207 (113.23 cm) Door = 16.821" (42.73 cm Depth =) Backbox = 16.65" (42.29 cm) (13.353 cm) Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) HI Left Side Right Side Bottom Cabinet Measurements Page 2 of 4— DF-52416:D • 07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - T134 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5UD-3 and MS-1OUD-7). Alarm Zones 6- 10 on TB6 (MS-1 OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - T135 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form C Relays - T138: Relay I (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - T139: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - T132: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-lOU D-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-lOUD- 7(E) main circuit board and to J7 on the MS-1 OUD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-524160 • 07/26/2010 -Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators .8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.0 A MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00' (50.80 cm.) high —22.5" (57.15 cm.) wide —8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F Agency Listings and Approvals The listings and approvals below apply to the basic MS-51JD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:0214 MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. &MMUFACTING QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:D • 07/26/2010 Calculating the System Current Draw Power Supply Calculations 7.3 Calculating the System Current Draw 7.3.1 Oyerview The control panel must be ablet&power all internal and external devices continuously during the non-fire alarm condition. To calculate the non-fire alarm load on the system power supply when primary power is applied, use Calculation Column i in Table 7.3 on page 118. The control panel must support a larger load current during a fire alarm condition. To calculate the fire alarm load on the power supply, use Calculation Column 2 in Table 7.3 on page 118. The secondary power source (batteries) must be able to power the system during a primary power loss. To calculate the non-fire alarm load on the secondary power source, use Calculation Column 3 in Table 7.3 on page 118. When calculating current draw and the battery size, note the following: -Primary' refers to the main power source for the control panel 'Secondary' refers to the control panel's backup batteries All currents are given in amperes (A). Section 7.2 shows how to convert milliamperes and microamperes to fill amperes. To convert.. Multiply Example Milliamperes (mA) to mAx 0.001 3 mAx 0.001 = 0.003A amperes (A) Microamperes (PA) to PA x 0.000001 300 pA x 0.000001 = 0.0003 A amperes (A) Table 7.2 Converting to Full Amperes 7.3.2 How to Use Table 7.3 on page 118 to Calculate System Current Draw Use Table 7.3 on page 118 to calculate current draws as fnlows: Enter the quantity of devices in all three columns Enter the current draw where required. Refer to the Device Compalibiiily Document for compatible devices and their current draw Calculate the current draws for each in all columns Sum the total current for each column Copy the totals from Column 2 and Column 3 to Table 7.4 on page 119 Following are the types of current that can be entered into Table 7.3 on page 118: / Calculation Column 1 - The primary supply current load that the control panel must support during a non-fire alarm condition, with AC power applied. 1' Calculation Column 2 - The primai' supply current load that the control panel must support during a fire alarm condition, with AC power applied. / Calculation Column 3 - The standby current drawn from the batteries in a non-fire alarm condition during a loss of AC power. MS-5tJD & t'fS-IUUD Series Manual P/N 52626:C4 3/7/20 14 117 Power Supply Calculations Calculating the System Current Draw Table 73 contains three columns for calculating current draws. For maximum output current avail- ability per circuit and per panel, refer to Section 1.2, "Specifications", on page 15. For each col- umn, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 119. Calculation Column I Calculation Column 2 Calculation Column 3 Device Type Primary, Non-Fire Alarm Current Secondary, Fire Alarm Current Secondary, Non-Firs Alarm (amps) (amps) Cunt (amps) Qty I X(current I I Total Q X [current draw] I Total Q X[current Total draw] = I draw]= Main Circuit Board MS-5UD X[0.110]= X[O.2141' 2= x(o.11O]= or 1 1 1 MS-lOUD X[0.1331= X10.282]'.2.. X[0.133] CAC-5X . I X[0.001)= [ I X[0.001]= } X[0.001]= 4XTMF f ] X[O.005J= I I X[O.O1lJ1 [ ] X[0.005]= I max. 1 max. 1 max. ANN-SEC card I X[O.003]= I J X[0.003]= I I X[O,003]= 1 max. 1 max. 1 max. ANN-80(C) I X[O.037]= I I X[0.040]= [ I X[0.015]= ANN-I/O I XO.0351= ] X[0.200]= ( ] X[0.035] ANN-RLY ] X[0.015]= ] X[0.075]= [ ] X[0.015]= ANN-(R)LED X[O.028= J X[0.068]= [ ] X[0.0281' ANN-S/PG - J X[0.045]= ] X[0.045]= [ I X[0.045]= 2-wire Detector - X[ ] = [ ] ' X[0.040]= [ ] X[ 14 Heads 4-wire Detector [ 3 X[ 14= [ 1 1 X(0.040= [ ] X 14= Heads Power I ] X[0.025]= ] X[O.0251= [ ] X[0.0251= Supervision Relays6 NAC#1 [ I X ] NAC#2 [ I X[ 1 NAC #3 EI)= lor 11=0 NAC #4 Current Draw 1 1= from TBO (nonalarm) Sum each column7 for . Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm = totals Table 7.3 System Current Draw Calculations If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. An ANN-LED is supplied standard with the MS-5UDC and MS-IOUDC. Refer to the Device Compatibility Document for standby current. Enter the number of IDCs used minus one. Must use compatible listed Power Supervision Relay. Total current draw listed above cannot exceed 3.25 amps for the MS-5UD-3(E), 3.28 for the MS-1 OUD-3(E), 7.25 for the MS-5UD-7(C/E), and 7.28 for the MS-10UD-7(C/E). 118 MS-5UD & MS-lOUD Series Manual- P/N 52626:C4 3/7/2014 (.'nlculaiing the Batte..y Size Power Supply Calculations 7.4 Calculating the Battery Size Use Table 7.4 to calculate the total Standby and Alarm load in ampere hours (AR). This total load determines the battery size (in All), required to support the control panel under the loss of AC power. Complete Table 7.4 f lows: Enter the totals from lahIe 7.3 on page 118, Calculation Columns 2 and 3 where shown Enter the NFPA Standby and Alarm times (refer to NFPA Requirements' below) Calculate the ampere hours for Standby and Alarm, then sum the Standby and Alarm ampere hours Multiply the sum by the derating factor of 1.2 to calculate the proper battery size (in Al!) Write the ampere hour requirements on the Protected Premises label located inside the cabinet door Secondary Standby Load Required Standby Time (total from Table 7.3 Calculation (24 hours) Column 3) I ] X[ J = AH Secondary Alarm Load Required Alarm Time (total from Table 7.3 Calculation (for 5 mm., enter 0.084. Column 2) for 10 mm., enter 0.165) Xf J AH Sum of Standby and Alarm Ampere Hours = AH Multiply by the Derating Factor X 1.2 Battery Size, Total Ampere Hours Required = AH Table 7.4 Total Secondary Power Requirements at 24 VDC 74.1 NFPA Battery Requirements NFPA 72 Local, Central and Proprietary Fire Alarm Systems require 24 hours of standby power followed by 5 minutes in alarm 7.4.2 Selecting and Locating Batteries Select batteries that meet or exceed the total ampere hours calculated in Table 7.4. The control panel can charge batteries in the 7 All to 26 Al-I range. The control panel cabinet is capable of housing batteries up to 18 All. Batteries larger than 18 Al-I require the BB-26, BB-55, or other UL listed external battery cabinet. For Canadian applications, the minimum battery size is 12 AH and the maximum battery size is 18A H. Pv(S-5(]L) & US-IUUD Series Mthival— PIN 52626:C4 31712014 119 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL fim ' - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7165-0075:0214) Page 1 of I CATEGORY: (7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)) LISTEE: (FIRE-LITE ALARMS lNCDne Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS- 5UD-7E,(fS-10Ub) MS-I0UD-3E, MS-10UD-7, MS-I0UD-7C AND MSI0-UD-7E(Fire alarm control unThe MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANN..SEC; Secondary ANN-BUS Module *IPDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) Length 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) Characteristic 4.8 108 DISCHARGE CHARACTERISTICS AT 25 C(770 F) > 0) 2 > U C L I I I I I I I, 1 2 3 5 10 20 30 60 2 3 5 10 20 30 h ME Discharge Time CHARGED too 230 CHARGED VOLTAGE 00, 20 L.5 0 0 CHARGING CURRENT 0 5 10 15 20 25 30 35 40 Chargeing Time (h) Cycle service life 12 I0 so - :: -W ,!P Deehameept 50% 06 a'gdep050 40 - 20 - 200 400 600 800 1000 1200 Life (Cycle) POER KINGDOM ad-Acid Batteries P37-12 (2v7Ah) Capacity 77°F(250C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah lh rate 4.20Ah 15 min rate 3.15Ah Internal Resistance Full Charged Battery 77°F(250C) 25m Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 770F(25°C) 100% 32°F(0°C) 85% 50F(-15°C) 65% Self-Discharge 68°F(200C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal Ti , T2 Charge (Constant Voltage,250C) Cycle 14.5-14.9V(-24mV/°C) max. current: 2.1 A Float 13.6-..13.8V(-18mV/°C) Constant Current DiacharL, Characteristics (A.25C) FN/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1. 15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Current Diachare Characteristics (Watt.25°C F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4.33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 significant advancement in conventional detect) System Sensor i3 series smoke detectors represer The j3 family is founded on three principles: instai,. Photoelectric Smoke Detectors SYSTEM $ SENSOR ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> 0 MEA MSFM CUS LISTED APPROVED approved approved S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, I heads plug into the base with a simple Stop-Drop 'N Lock action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms. 2-wire P detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Smoke Detector Specifications Smoke detector shall be a System Sensor j3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2W7-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions, When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. IElectricalF1I1IiT1iTiT!L.], Operating Voltage Nominal: 1 2/24 V non-polarized Minimum: 8.5V Maximum: 35V Peak Standby Current 2-wire: 100 jjA 4-wire: nla Alarm Contact Ratings 2-wire: rVa; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 4900; 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2'C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information () (Tr) (13 max. lIted by controTpanel) 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter "STEM 3825 Ohio Avenue. St. Charles, IL 60174 Productspecifications subjectto change without noscavtsystemsenocncomfor 02009 System Sensor. SENSOR Phone: 800-SENSOR2 . Fax: 630-377-6495 current product i 3mra0050 includingthe latestverdonof this data sheet. 605-0316.007 .6/00. #2169 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7272-1653:0152) Page I of I CATEGORY: (272 ---SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC) LISTEE: (ystem_Sens)Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: (Models 2WLB)2WT-B, 4W-Band 4WT-BhotoeIectric type smoke detectors. Models 2W-B) and 2W1-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2W1-B and 4WT-B employ a thermistor type heat sensor (1350F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expire (une 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 10/4/2018 System Sensor 2-wire Compatibility for MS-I OUD-3 by Fire-Lite 2-wire Compatibility for j:- Manufacturer: Fire-Lite SENSOR' Model: MS-I OUD-3 Detector Base Max Zone Zone Style EOL Model Model Detectors Model ID 1 B110LP, I N/A/ CAC- 4.7K! 2151(T) 20 B,D A B401 5X N/A 2W-B N/A/ CAC- N/A 20 B D* 4.7K / A 5X ' N/A 2WT-B N/A / CAC- N/A 20 B 0* ' 4.7K A 5X N/A 2WTA-B N/A / CAC- N/A 20 B D* 4.7K / A 1 5X N/A 2WTR-B I I N/A N/A CAC- B 0 * 4.7K ! A 5X N/A BIIOLP, N/A CAC- 20 B,D 4.7K! A 5151 B401 N/A N/A CAC_ D2 I N/A 20 B,D 4.7K! A 5X https://www.honeywellflre.com/sys/2wirecomp/2wirpmt.php?panelMS-1 OUD-3&co=FThe-Lite 1/1 CT G- 7 F S (LTE-VL 7N: T CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD COMMERCIAL FIRE PRODUCT FEATURES . Certified for use on Verizon's LTE network for long, sunset- free installation. P Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems * For the most current product specifications and UL Listings visit www.Tetguard.com. TG=7FS CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD LTE-V P/N: TG7LVFO1 Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. Telguard, a Division of Telular Corporation• 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.Telguard.com • Copyright @2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1402:0110) Page 1 of I CATEGORY: LFire Alarm Control Unit Accessories/Misc. Device) LISTEE: 1ULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LVO0I *TG7LVA01, jG7LVF0and TG-KlT(gitaI cellular communicato) Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04-07-2017 dcc , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DISCHARGE CHARACTERISTICS AT 25 C(77 F) • ..uuiiii.iui.0 oil uui.0 #uuuhi.. ME uuuuiuuiiiiuuouu, uIhUhIR•IIRuIlI, uuuuiuutUiiiLuuiiiiuu. U111UftU1UU11•IIIIIII I.: I 2 3 5 30 20 30 60 2 3 5 10 23 30 rr1 Discharge Time loot CHARGED 634 VOLUME ......_.__- CHARGED 60 VOLTAGE 60 0,08 200 0.06 40 20 CHARGING CURRENT 0 5 II 15 20 25 30 35 40 Chargeing Time (h) Cycle service life 21 000 D.cIwge pe mN Omfl&g,d,pt Or. Iwge depS 30 W% o 200 400 600 200 1000 1200 Life (cycle) U POER KINGDOM (Sealed Lead-Acid Batte_s I Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height Length 3.74 inches (95mm) 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) Characteristic Capacity 770F(25°C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah I rate 4.20Ah 15 min rate 3.15Ah Internal Resistance Full Charged Battery 770F(250C) 25m Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 77°F(250C) 100% 320F(0°C) 85% 50F(-15°C) 65% Self-Discharge 680F(20°C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal Ti , T2 Charge (Constant Voltage,250C) Cycle I 14.5.44.9V(-24mV/0C) max. current: 2.1 A Float 13.6-43.8V(-18mVI°C) Constant Current Diacharg Characteristics (A.25C' Zi42 (.21V7Ah) 4.8 108 o:o. F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1. 65 1.10 0.68 0.35 Constant Current Diacharg Characteristics (Watt.25C F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4. 33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 (E)POTTER The Symbol of Protection U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2' thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal. A field in- stallable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. VSR-F ANE TYPE WATERFLOWL kRM SWITCH WITH RETARD UL, ULCandCSFM Listed, FMand LPCBApproved, NYMEA Accepted, CE Marked Service Pressure: Upto450 PSI (31 BAR) Minimum Flow Rate for Alarm: I0GPM(38 LPM) Maximum Surge: 18 FPS (5,5 m/s) ContactRatings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA4/1P54 Rated Enclosure- use with appropriate conduit fitting. Temperature Range: 40°F/1 20°F, 45°C149°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be in- stalled within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2' (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833www.pottersignal.com PRINTED IN USA MKT. #8800001 -REV W PAGE 1 OF 2 MEG. #5400761 - 7/02 FIG.4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. DWC, 76I-.4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG. 2 OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS, A "8" SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO "B". TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 5011 -LBS (68 n-m) OF TORQUE 00 No .01 DWG. 1023-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. TO INSTALL, DRILL HOLE AS INDICATED: Cover Tamper (with cover in place) DIRECTION OF WATERFLOW C NO NC (wHr) (RED) (BLK) MO. IM1NTI-2 DWG. #761-30 MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) o O 1 A 10-2512040]35—-55 B C 0 50-70 E 60-90 PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8" -1/16" (50mm to 65mm) (33mm ±2mm) to 8" 2" ±1/8" (80mm to 200mm) 50mm ±2mm) FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to 2 SETS OF operate a central station, pro- NOR MAU.Y OPEN .CTS CLOSE ON ALLOW WATERPLOM zoom EOLR FROM ON ORE noE prietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. _________ A condition of LPC Approval of ThE NC AND NO uAROTNGS POSITIVE DC OR NEUTRAL AC'—! this product is that the electri- ON THE SWITCH ARE FOR OR LOT AC BELL cal entry must be sealed to AN ALARM CONDITION. THE CONTACTS RAC REVERSED NEGATIVE DC exclude moisture. WHEN THE DERCE IT IN EWE. P61-2 THE NORMAL CONDITION. For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). APPLICATION WARNINGI Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV PAGE 2 OF 2 MFG. #5400761 - 7/02 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:Op) Page 1 of I CATEGORY: (7770 - VALVES/SWITCHES) LISTEE: (ter Electr Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BilIWpottersignaI.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D (VSR-J VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PS10 PS-10A PS-100A WFSR-F PSIOO INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and *2n steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2fl plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 400F. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (LiingExpJj (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ® POTTER __ (OSYSU1 TSIDE 2__ SCREW AND YOKE VALVE The Symbol of Protection (SUPERVISORY SWITCH) UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, con- taining two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover Dimensions: 6.19"L X 2.25"WX 5.88"H 15,7cm LX 5,7cm W 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduitfittings. Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 screws and hex keys are available. See ordering informa- tion on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring sys- tem should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833www.pottersignal.com PRINTED IN USA MKT. #8820004 - REV P PAGE 1 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-11 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. I SMALL VALVE INSTALLATION - 1/2" THRU 2112" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2" (12,5MM). J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. [01 WE LTA I CARRIAGE BC SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 SMALL VALVE INSTALLATION Remove and discard "C' washer and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8' (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16" (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 2 OF 4 12101 (E)POTTER The Symbol of Protection OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES, MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF SWITCH ON BRACKET. YOKE VALVE STEM TRIP ROD DWG. #979-4 J_— -}, ' GLAND LARGE VALVE INSTALLATION With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 proce- dure. Mark the valve stem at the center of the trip rod Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 FIG. 4 PARTS ID LA C K) KNOCKOU1! FOR £LKCTRICA CONNECTION: RED DREW DUO ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke-Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke-Supervisory Switch (Double switch) 1010206 - Cover Screw 5490344 - Hex Key for Cover Screws and Installation Adjustments 5250062 - Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. OPEN VALVE POSITION COy. NO SW #1 COM. NO SW #2 CLOSED VALVE POSITION C o SW #1 N.C. cN.O. SW DWG. #979-2 (E)POTTER OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH FIG. 3 DIMENSIONS I ROD OCTMOED IJ Mr. 1979-9 DC. flfl-7 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL DING. p923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion of the connection in the event that the wire becomes dislodged from under the terminal. TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT NO. INDICATING TO POWER FOR COJIN.C. DEVICE INDICATING DEVICE I TO SUPERVISORY CIRCUIT N.C. END OF OF CONTROL PANEL LINECO N.C. i RESISTOR I DWG. #979-1 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION BREAKING EXCESSIVE ROD LENGTH FIG.5 PRINTED IN USA MKT. #8820004 - REV P PAGE 4 OF 4 12101 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL M'140 ~ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7770-0328:0013 Page 1 of I CATEGORY: (7770 -- VALVES/SWITCHE LISTEE: (Potter Electric Signal Co1609)Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillW©pottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W PS-120A OSYSU-2 PTS-B (oSYSu-i) PIVS-B iTS-S WLS PTS-C RBVS *PSI5 WLS-S PS-40A OSYS-B PMS GVS PCVS-1 TTS-W PCVS-2 PS4O PS12O *P525 INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 *Revision 09-07-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expires J çiie 30, 2020) Authorized By: DAVID CASTII..L.O, Program Coordinator Fire Engineering Division SECTION2 FIRE ALARM CABLE I PART NUMBER AWG CONDUCTOR SHIELDED! OVERALL i I UNSHIELDED DIAMETER CONDUCTOR JACKET COLOR I VOLTAGE RATING WEIGHT (Ibs)IUnht [ MARKINGS TEMP PUT UPS I BLACK, WHITE, I WHITE 300v I 18.0 I ADT 494469 60°C 500 RED, GREEN, LBS 12/C 22 AWG REEL BROWN, BLUE, TYPE FPLP/ ORANGE, YELLOW, CmP VIOLET, GRAY, PINK, TAN BLACK, RED RED 16.0 ADT 493490 75°C 1000 LBS 2/08 AWG BOX TYPE FPLP/ ,- CMP (NI) (UL) 8.0 ADT 493490 500 LBS 2/C 18 AWG BOX TYPE FPLP/ CMP () (UL) LIGHT BLUE, 16.0 ADT 493493 60°C 1000 YELLOW LBS 2/C 18 AWG BOX TYPE FPLP/ CMP (UL) 8.0 ADT 493493 500 LBS 2/C18AWG BOX TYPE FPLP/ ,-.. CMP (UL) I 2.20 DON'T SEE IT? CALL 1-888-423-8947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 !\J I 2.21 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (161-2075:010OJ Page 1 of I CATEGORY: 17161 -- CABLES-FIRE PROTECTIVE SIGN AT LISTEE: (Paige Electric Companyp)Springfield Road, Union, NJ 07083 Contact: Cindy Regner (908) 687-7810 Fax (908) 687-8860 Email: cregnerpaigeelectric.com DESIGN: Types FPL, and FPLR power limited fire protective signaling cables. Insulation - PVC compound AlphaGary Smokeguard 4010, Synergistics 1349-1028 FRD, 1360-1021-PID, PP, HDPE or LOPE. Shields - (Optional) All metal or Aluminum Polyester tape. Braid - (Optional) All metal. Jacket - PVC compound AlphaGary Smokeguard 11 6920, Gifto Global GA-8705-03, AlphaGary GW2038, Synergistics 1690-1060,1604-1007 FR, 1100-1092 FRD, JAP6IA or 1410-1011 FRD, Solef 31008-0003. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type FPL, FPLP or FPLR, rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. NOTE: Formally 7161-1677:100 XLF: 7161-1509:0100 mt09-09-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing ExpJJ (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division