Loading...
HomeMy WebLinkAbout2726 LOKER AVE W; ; FPC2017-0117; Permit4LC PERMIT REPORT Cdisbad ityof Print Date: 12/02/2020 Permit No: FPC2017-0117 Job Address: 2726 LOKER AVE W, CARLSBAD, CA 92010-6603 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090812800 Track #: Applied: 05/08/2017 Valuation: $51,161.00 Lot #: Issued: 06/21/2017 Occupancy Group: Project #: Finaled Close Out: 12/02/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: SAMTEC -SPRINKLER TI 7-100 HEADS (11) OFFICE TO OFFICE TI TO EXPAND LAB Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAllMIN DEEKEN 9925 PROSPECT AVE, #STE B 9925 PROSPECT AVE, # B SANTEE, CA 92071 SANTEE, CA 92071 (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tq a Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch'(15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-B Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The Series TY-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315 ......Upright 5.6K, 1/2" NPT Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/barl'2) FEBRUARY 2014 Temperature Ratings 135°F (57°C) 155° F (68°C) 175°F (79°C) 200° F (93°C) 286°F (141°C) 360°F (182°C)t t UL, C-UL, and VdS Approved only Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI52 2-7/8' (73,0 mm) DIA. TFPI52 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly *Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 I (11,1 mm) NOMINAL 2" MAKE-IN _____ (50,8 mm) _ 2" 1-3/8" _ (50,8 mm) N I (34,9 mm) I WF Fl 1/2 NPT** DEFLECTOR* 6- STYLE 15or20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT 'TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI52 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING i 5/8' (15,9 mm) FLUSH 3/8±5/16' (9,5±7,9 mm) MOUNTING 1/8' J SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. (7,9±6,4 mm) \ 01(3,2 mm) FITTING (57,2 mm) 5/16±1/4" 1/2' (12,7 mm) FLUSH MOUNTING 1/8" SURFACE' CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI52 Page 4 of 4 PIN* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS I 570 I 5.6K UPRIGHT (1/2NPT) TY315 1 NATURAL BRASS 571 5.6K PENDENT (1/2NPT) TY325 POLYESTER PURE WHITE (RAL9O1O)** Use suffix "I" for ISO 7-1 connection; for example, 77-570-4-175-I SIGNAL WHITE (RAL9003) POLYESTER 175 175-F (79-C) 9 CHROME PLATED Eastern Hemisphere sales only OPEN indicates sprinkler assembly without Glass Bulb, Button, and Sealing Assembly TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135-F (57-C) 155 155°F (68°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F(182°C) 000 OPEN*** Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqca TEFLON is trademark of The DuPont Corporation. Fire Protection Products MALLEABLE IRON 1 11 Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ______________ Pressure _ Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar ps bar 200 to 1500 -28.9° to 65.60 300 20.7 500 34.5 600 41,4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 224 5000 260.00 - - 180 12.4 280 19.3 5500 287.80 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®Us APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 Sizes /4"1" (6-25 mm) Sizes 11/4"-2" (32-51 mm) Sizes 2Y2-3" (64-76 mm) (°F) (°C) psi bar psi bar psi bar psi bar -20° -28.90 to to 1500 65.60 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93,8 1,050 72.4 735 50.7 3500 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 550° 287.8 - - 300 20.7 300 20.7 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES % (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) www.anvilintl.com 17 I Ma 0pST TO II best sprinkler p in the industry! c®us LISTED <> APPROVED I ONFSA NFPA BULL MOOSE TUBE COMPANY WIM Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com A sales@bullmoosetube.com 800.325.4467 c®us LISTED APPROVED ONFSA NFPX 2 Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED <> APPROVED I;] z4 ONFSA NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MlC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tubes reserves the right to change product specifications without notice and without incurring obligation. c®us LISTED <> APPROVED no A ONFSA NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. SIZE (IN) (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 - 1.315 1.097 1527 141 lbs/ft 1.820 _!1_ [ 1T14 ir 1.600_____J F 1.442 9.1 F18TIbiif7L 2=518 lL__61 j 1-1/2 1.900 1.682 776 209 lb /ftjT3 053 611 - r 2 [ 237][2157 1L 627 J[264 IbflL 4223 J[ 37 - 21/2 2.875 F777T05 1 492 1 3531bs/ft 5893 30 1 3 -IL 3.500 ]r 3.26OiTIL 3.54 IL 4.341b5/ft1E7.957 r— 19 1 4500 4260 r2501 5621bs/ft _11._79-6—- 19 j SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) O.D. (IN) I.D. (IN) WATER FILLED BUNDLE CRR** WEIGHT/FT WEIGHT SIZE 1 -1315 I_1.049 ___100j_1Ib/ft 2.055 70_ 1 1-1/4 1-.0_11 _1380 11_100 1[ 227ft][ 2 ][ _51 07] rT6TO 1.00 32.72 Ibs7ft i 44 [ _2 1 _2375 11_267 _]t 100 1[366Ib/ffTT1L 5114 1Eo 11 TTii TÔ LiIsliít 1L 1 30 L 3 T1 L 3500J [ 8_ IL 100 ] [75iI6s/fF L _10783 I1t_19 4.500 4.626 - - fOo - 1080ths/ft 1631 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com ) Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande AZ Dallas TX Masur OH BULL MDDBE flJBE COF*IPANV 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. FireLock® Outlet-T ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-I provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1V4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWN ER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date www.victaulic.com vicruic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV \4taulicr iO.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I _ i I , Hole Diameter Dimensions - inches/millimeters ½ 1 3A6 130 _____ 1¼ 1.83 1.10 3.87 F2.S6 15 30.2 33.0 1.0 32 46.5 27.9 98.365.0 0.45 ~ 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 ½ 1 '/16 1.42 1.95 1.22 4.08 2.56 1.2 x 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1 3A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 3/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 1,5 13A6 1.66 2.19 1.46 4.60 2.56 1.3 x 50 15 30.2 42.2 55.6 1 37.1 116.8 65.0 0.59 3/4 3,54 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 112 1/16 1.91 2.44 1.71 5,40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1/6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 13A6 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1A6 1.89 2.44 1,71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 1397 65.0 0.73 1 13A6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 STYLE 922 DIMENSIONS l.;'Lyl 'f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 JtauIicr REV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1UU3 PERFORMANCE Run Size I17mm x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT 1€thters 32 2S 1 112 1 x 50 .4. 21/2 x 1 65 25 * Hazen-Williams coefficient of friction is 120 FireLock® Outlet-I STYLE 922 www.victaulic.com \jltauIiC VICTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PFV ( 3 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com '.JtauIic 10.52 3355 REV G UPDATED 12/2009 vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. 10.52 /AcSn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEELICPVC 1/2 & 3/4 inch pipe 5 thru 8 Inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - USTED 203-EX 25511"- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-l71E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPAI3 PIPE ROD I W1 5 WT.-250 UL TEST LOAD 1 3/8 3075 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 634.75 750 21/2 3/8 118,35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3605.00 4050 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement ofpipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly, Be advised the following warranty restriction will apply. DISCLAIMER - AFCON wilt NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequentiul damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 fl Product Features -No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. 1/4" 8002957 GST 100 1/4x1" 210 ( 16 OS B) 670 (3/4" Ply) 25 125 _ Nut Driver Pad #8113910 1/4" 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 1/4 8004957 GST 00 1/4x3" 2060 (Fir ) 25 125 1 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/81,8007957 GST 10 1/4 x1" 300 25 125 ] 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GTS 174x2" 1760 (Fir) 850 25 125] 3/8" 8009925 08125-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 3/8 8010957 GST 30 1/4 x 3 2060 (Fi!) 1500 14 25 i5 j 3/8 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 3/8 8011925 GST 40 1/4x4" 2180 (j 25 1257 3/8" 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 - L_ 1/2" 83925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1 #14 SW Red 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2 801925 0813 1/4x3 2275 (Fir 25 125 1 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 F 1/2 8017925 GST6 1/4x6 2230 (y) 25 125 } Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. "Accommodates up to 3 %" x 12 pitch roof. "Reduces installation cost. "Allows IT deflection from vertical. • Made in the U.S.A. - J 3/8" 8139957 SH-GST2O 1/4x2" 1257 Fir) 1050 1475 25 125 125] 3/8 8141957 SH-GST30 1/4x3 1720 (Fir) 1500 1475 25 125 #14 Black SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each Nut Driver time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. (1) EMTWM V ( 0 DR For the most up to date information, visit www.sammysuperscrew.com 4-1' _.,j IN Floor Joist Product Features 'No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. Not less than 2' nominal width (1-1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe Minimum 2-1/2' from bottom for branch lines. Minimum 3' from I , bottom for main lines. Exception: This I requirement shall not apply to 2' or thicker nailing ships resting on fop of . I steel beams. I U I - #14 SW Red Nut Driver 1/4 8018957 S. 1/4x1' 622 (Fi 25 12QJ 1/4' 8019957 SWG 200 1/4 x 2 1725 (Fir) 25 125 YL SWG 10 1/4 x1'622(Fr)300 25 125 1 _3/8_8020957 ., 3/8 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 2MS 1/4 x 2" 1 L FirL 850 25 125 1 k, 3/8 8022925 SWG 25-380 3/8 x 2-1/2' 2249 (Fir) 1500 25 125 3/8' 8023925 SWG 30 -- 1/4x3 1884 (Fir) 25 125 1 Part #8114910 r1NAATIQN STEPS NTO W000& STEEL: I IINSTALLATION STEPS INTO WOOD& STEEL insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #145 W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.