HomeMy WebLinkAbout2765 LOKER AVE W; ; FA150063; PermitFire Alarm Permit Job Address: 2765 LOKER AV WEST Permit Type: FALARM Parcel No: 2090811800 1E!s] Reference No.: Permit No: FA150063 Status: APPROVED Applied 9/24/2015 Approved: 9/24/2015 Issued: 9/24/2015 PC #: Inspector: Project Title: NORDSON - ASYMTEK Install new fire alarm system in an existing one story with mezzanine. System to be automatic sprinkler monitoring with notification throughout the building. Install horn/strobes and strobes thrgouhout the building. New FACP to be mounted in electrical room. Elevator recall function is part of this system. Connection to 41 duct detectors as shown on plans. Applicant: NORDSON - ASYMTEK 2765 LOKER AV WEST Owner: REALTY ASSOCIATES FUND VIII L P C/O TA ASSOCIATES REALTY 1301 DOVE ST #860 NEWPORT BEACH CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 370 0 370 0 MLcx.3 NORDSON - AYMTEK 2765 LOKER AVE. CARLSBAD, CA. 92010 Fire Alarm Submittal 09R6/15 Submitted By; NVA SECURITY 8779 COTTONWOOD AVE. Suite 103 Santee, CA. 92071 619-448-3007 Cont. Lie. C- 10 # 802053 APPROVED AS SUBMITTED CARLSBAD FIRE DEPARTME @ I A __ 7160328:019 NYC Fire Dept Certificate of Approval 6155 Product includes a 5 year warranty Description ' (DPOTTER Cii-iOO) The Symbol of Protection FIRE ALARM CONTROL PANEL Features 127 points expandable to 1,016 by use of seven SLCE cards 10 Amp Power Supply 6 NACs regulated, rated at 3 amps each 4 multiftinctional input/output (I/O) circuits for flexibility rated at 1 amp each Strobe synchronization for Potter/AMSECO®, Gentex®, Cooper/ Wheelock® and System Sensor® 1,500 Software zones for versatile installation options 4 x 40 LCD and keypad for ease of operation Dual P-Link communication circuits for annunciation and accessories Optional dual line digital alarm communicator reports by panel zone or point ID Ethernet port for programming. reporting and network connectivity E-mail system status, reports and event information Built-in IP communicator supports report by point, zone or panel Size (W x H x D): 17 5/8" x 26' x 3 3/4" Electrical Specs Battery AC Mains 160 mA Standb) 5.0 amps @ 120 VAC 50/60Hz 3.0 amps 240 VAC 5016011z The PFC-6800 is a single loop expandable to eight loop analog/addressable fire alarm control panel. The panel utilizes the Potter/Nohrni device protocol that has a complete line of initiating and control devices. The SLC is capable of 50 ohms of resistance and does not require time use of twisted or shielded wire. The on board Signaling Line Circuit (SLC) supports 127 of any combination of smoke sensors, heat detectors or modules. Up to six additional SLC cards may be added in the control panel. Some or all of the SLC cards may be remotely installed to provide an additional 127 points bringing the total system capacity to 1,016 points. The PFC-6800 has a metal cabinet with a key lock and a dead front standard. The cabinet will house 8 Ali or 18 Ali batteries and the panel has the power to charge up to 55 Ali batteries. The large LCD and window allows easy viewing of the system status and the standard LEDs. The keypad allows easy operation and navigation of the system menu. The panel has auto-programming learn mode that will not affect the existing system when adding or deleting a device. The system is capable of 1,500 software zones, cross zoning and counting zones. The panel is fully programmed from a PC based software program that will work with Microsoft XP Vista or Windows 7.0 operating systems. The PFC-6800 has an Ethernet connection for programming network connectivity and IP reporting communicator. The system uses a simple patch cable for connecting a PC to the panel. In addition, the system may be connected to a building network and programmed while on the network. The system has a built in e-mail function and will send system E-mail reminders The IP communicator is listed with the Sur-Gard III IP receiver. The panel will support P-Link devices which include: the RA-6075. RA-6500 and LED-16 Annunciators, RLY 5 Relay Module, SPG-1000 Serial Parallel Gateway (printer card), FCB- 1000 Remote Ethemet/IP connection, DRy-SO LED driver for 50 LEDs, PSN- 1000 Remote Power Supplies (10 Amp) and FIB- 1000 P-Link Fiber Interface Module. In addition, the panel allows for the installation of the UD-1000 dual line telephone line digital alarm communicator transmitter (DACT). The UD- 1000 is programmable for a single line or dual line and is compatible with Ademco's Contact ID or SIA DCS protocols. The SLCE-127 may be installed with 6,500 feet of the control panel and may be installed in theAE-8 eight slot orAE-14 fourteen slot expansion cabinets. Another option is to install the SLCE- 127 in the PSN-1000E intelligent power supply to allow remote installation of the loop adder and system synchronized notification circuits. Each PSN- 1000 acts as a P-Link repeater and will repeat the communication to allow the installation of the remote loop thousands of feet from the main control panel. The complete system may be converted to Class A with a CA-6500 module. The CA-6500 provides the hardware necessary to convert the remote annunciators through the Potter P-Link connection protocol, the NACs and the SLC to Class A operation. Potter Electric Signal Company, LLC• St. Louis, MO • Cust Service: 866-956-1211 •Tech Support: 866-240-1870 • Canada: 888-882-1833• www.pottersignal.com PRJNTED IN USA MKT. #8830029 - REV B PAGE 1 OF 3 11,13 (E)POTTER FFC-6800 The ction FIRE ALARM CONTROL PANEL Symbol of Prote SLC Loop Accessories The control panel may be connected with up to 1,016 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA' Analog Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 1350 Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 1350 F to 185°F Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4' round base that is mounted to an electrical box and wired for connection of one of the above sensors AIB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC. One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The sounder follows the pattern sent to the device. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4) Single Contact Module is a standard contact module with an LED that mounts into a 4" square electrical box. (pCM-4) Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. (RI\4) Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125 VAC. MOM-4 Monitored Output Module switches monitored power and is activated by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors. SCI Short Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. P-Link Devices Device Description RA-6075 LCD/keypad remote annunciator with a metal enclosure and key lock. RA-6500 160 Character LCD. Keypad remote annunciator with metal enclosure and key lock. LED-16 LED remote annucniator capable of displaying alarms, supervisory, and trouble status for 16 zones. PSN- 1000 10p Intelligent power supply. RLY-5 5 Form C Relay Card. SPG-1000 Serial/Parallel Printer Card, Optional Rack Mount. FCB-1000 Fire Communications Bridge, I may be added for remote IF Communicator. FIB-1000 Fiber Interface Module, used in pairs to convert P-Link over multimode fiber, optional rack mount. PRINTED IN USA PAGE 2 0F3 MKT. 98830029 - REV B 11113 ' SPOTTER The Symbol of Protection (iJCD ANNUNCIATOR) - Features Operates with all Potter PFC-6000 series Industry leading 4 line by 40 Character LCD - • Common buttons for navigation Common LEDs for status indication - . . - • 31 annunciator per panel @p0T11R Maximum wire length of 6,500 feet Size (WxHxD): 9 13/16" x7 1/6" x 11/16" Electrical Specs U (tandby Current 20 0 CA 11. Current 50 mA S2930 7165-0328: 0195 Product includes a 5 year warran4 Description The RA-6500 is a LCD remote annunciator for the PFC-6000 Series addressable fire control panels. The RA-6500 communicates using a RS-485 connection to the main panel providing common indication ofAlarms, Supervisory, Trouble and other system status and control functions. The RA-6500 features a 4x40. 160 character LCD display with LED's for Power. Alarm, Supervisory, Trouble, and Silenced conditions. It can be mounted on a single gang electrical box or a four square electrical box. The annunciator is enclosed in a sheet metal enclosure and has a Potter lock securing the keypad. Installation The RA-6500 is connected to the fire alarm control panel using a four wire RS-485 connection. The connection is power limited and supervised. Up to thirty-one (3 1) RA-6500 LCD annunciators can be connected using Class B or Class A wiring. MM Install in accordance with compatible installation manual. Figure 1: Class B Wiring Example To the next annunciator Figure 2: Class A Wiring Example I Potter Electric Signal Company, LLC • St. Louis, MO • 800-325-3936. Canada: 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. 98830031 - REV 1 PAGE 1 OF I 11/Il CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0198 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: bilIwpottersignal.com DESIGN: Models *pFC..6500 *PFC..6500R P400 andFC-6800 fire alarm control panelsAutomatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: CA-6500: Class A Expander UD-1000: DACT *3006607*3006610*3006623*3006623*3006618 : Main Boards RA-6075, RA-6075R,A-650O: Remote AnnuciatoT 3005013, 3005012: EOL Resistors PSN-1000, PSN-1000(E): Fire Power Expander Models AE-8, AE-1 4; Power expander enclosures SLCE-127: Loop Expander RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTE: *For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 03-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 (ingExpjj) (Jiine30,2ö16 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division S (D POTTER The Symbol of Protection CPSN SERIES) POWER SUPPLY S UL, cUL, CSFM Listed PSN-64 has 6 amps regulated with 4 Outputs PSN 106 has 10 amps regulated with 6 Outputs r3p- 1 -1 ~., - -~ Outputs Rated at 3 amps maximum each May be configured as up to three class "A" Style "Z" notification circuits 3 amp. 24 VDC programmable output power Supervised Battery Charger: 27.3 @ IA (supports 7-55 AH batteries) Easy to install cabinet with leveling mounts and key lock Wiring knockouts provided on sides and top of cabinet Two Trouble Relays (5A at 30VDC) General System Trouble (programmable for AC delay) Low AC Trouble with optional delay settings Diagnostic LED's Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault (Amber), AC (Green). Battery Fault (Amber) patiit piiduig Trouble Memory feature captures troubles which have previously restored Synchronized notification appliance circuits Potter/AMSECO®, Wheelock®. Gentex®, System Sensor® Configurable output circuits (DIP switch sets options for each circuit) 15 inAat 8-33 VDC input trigger Reference EOL allows 2K - 27K EOL value to be used Quadrasync provides panel wide synchronization of same or multiple brands PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number: 3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps (&,240 VAC 3006446 PSN-106 Black Enclosure Standby Current 60t) L-Alarin Current 200 mA *no external load Description The PSN series of notification power supplies offers reliable notification Sensor® strobe devices. Each output can be configured the same sync power with unprecedented versatility. The power supplies offer either protocol or set independently. cuS 0111,LISTED S2930 7315-0328:0189 Product includes a 5 year warranty Dimenions: 16 1/8W x 16 3/4"H x 3 1/2°D UU••p •• •5• Each output is rated at 3 amps and it may be used continuously without any derating. The power supply operates on either 120 VAC or 220 VAC power input and has a regulated 24 VDC output. In addition, the panel can charge up to 55 AH batteries and leads the industry in housing up to 18 AH batteries. The cabinet is constructed out of 18 gauge cold rolled steel and has a durable red powder coat finish. In addition, a key lock is provided for securing the door. Ample electrical knockouts are provided on the sides and the top, allowing the installer options for running wires and maintaining the correct separations. The power supply offers an industry leading Quadrasync function that allows for multiple strobe circuits of different brands to be synchronized to flash at the same time. The panel can have four different brands each connected to its own circuit and all of the strobes flash together. In addition, the panel has an input PassThru mode allows the outputs to follow the input signal and sync up the input flash. The panel will recognize the type of input being supplied and pass this through to the outputs with the same pattern. This input pass through can be selected on each output independently. The power supply contains simple dipswitch programming and LED indications providing the installer indications of the operation and the ability to correct any faults. A Trouble Memory is provided to allow an installer to review past troubles and make the necessary repairs. Each output has an LED to pin point the exact circuit where a problem may have occurred. Relays are provided for monitoring the general system and AC failure. Each output and be independently configured for various applications and installations. Each output can be independently configured for Class A or Class B operation, constant power,ANSI Temporal Code 3, Single, Multiple or Combo Inputs or Door Holder Power. Each output can independently be configured to provide one of four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations. The panel can be configured . to synchronize Potter/AMSECO®, Gentex®, Whleelock® and System Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833• www.pottersignal.com PRINTED [N USA NET. #8910013 - REV C2 PAGE 1 OF 2 11/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7i328p183 Page 1 of 1 CATEGORY: 7315 -- POWER UNITS LISTEE: (Potter 8ectric S9ijCo1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN [Mod&sPSN106'PSN 64 PSB 10(Notificatlon App Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input 120/240 VAC 50/60Hz Output 24VDC @ 10A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the unit must provide battery backup suitable for at least 24 hours. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. I 01 -27-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer tolistee's data sheet, installation instructions and/or other Date issued: July 01, 2015 [Listing Expj ,June 3O,2i Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division POTTER0 Afa-HAN PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR Features c®us LISTED S24776 7165-0328:0194 Product includes a 5 year warranty Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with any fire alarm control panel that has the Potter! Nohmi protocol. The PSA is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an eggshell white to blend in with the ceiling. The PSA has a sensitivity range of 1.05 to 3.82% per foot and is UL S and cUL listed. The PSA may be configured for drift compensation and has built in dirty detector warning as well as. The PSA and the control panel communicate over a proven and robust digital communication path and the system analyzes the level of alarm at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The PSA has two LEDs that allow for 360° viewing. The sensor is compatible with any of the Potteri'Nohmi bases and simply twists on. The PSA is addressed using the hand held programmer or the control panel addressing function. Air Velocity Ratings The PSA has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 13 LEDs that can be turned on simultaneously. If the system already has 13 LEDs on, the PSA will operate even though the LED will not illuminate. Setting the Address Each addressable module, smoke sensor, heat detector and combination sensor/detector must have the address set before connecting the device to the SLC loop. Time address is set using the hand held device programmer or the addressing feature on the control panel. Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.05 to 3.82%/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple and accurate address setting without mechanical switches LEDs for 360° viewing Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. Specifications Item PSA Working voltage range 22.0 to 24.0 V Standby current (325 liA Alarm indicator 2 LEDs Alarm indicator current (1.2 mA D.C.) Alarm set-point range 1.05 to 3.82 %/41) 113.4 to 12.0 %!m Installation temperature range 32 to 120 ° F! 0 to 49 ° C Operating relative humidity range 00,-o" to 93% (Non-condensing) Start-up time Max. 1 sec. Maximum number of addresses per loop 127 Maximum number of lighted indicators in alarm per zone. 13 Color Eggshell White Weight (without base) 84g (2.960z) Dimensions (without base) Height: 1.33 in (34mm) Diameter: 4.0 inches (99mm) Approvals / Listings UL, cUL, CSFM 0 Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada: 888-882-1833 www.pottersignal.com PRINTED IN USA MKT. 98830015 - REV C PAGE 1 OF 2 06/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 72-O328:01) Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: jtter ElectncSignal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN Modelsfand PSHAFiotoelectnc type smoke detectors! Model PSHA employs a supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units when used in conjunction with listee's Models AB-4, AB-6, ASB, Al and ARB bases. Models with supplemental heat sensor are not approved for use in lieu of the required heat detectors. S 12-23-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date issued: July 01, 2015 (gExpirs (e 30, 2016) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division c®US LISTED S24776 A' 7270-0328:0193 P0TTER*Afia_HM1 RATE OF RISE/cIXED11EMPERATURE The Symbol of Protection HEAT DETECTOR S 0 Product includes a 5 year warranty Description The combination Rate of Rise/Fixed Temperature Heat Sensor (RHA) is a listed Analog/Addressable combination temperature heat sensor compatible with any fire alarm control panel that has the Potter! Nohrni protocol. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The sensor and base (not included) are made of a durable plastic in an eggshell white (off white) to blend in with the ceiling. The RHA is UL and cUL listed with a selectable fixed temperature point from 135° to 174° and a rate of rise feature. The rate-of-rise operates when the temperature increases 12-15°F occurs. The heat sensor is ideal for installations needing the earlier heat detection. The RHA has two LEDs that allow for 360° viewing. The sensor is compatible with any of the Potter/Nohrni bases and simply twists on. The RHA is addressed using the hand held programmer or the control panel addressing function. Spacing The RI-IA spacing is dependent on the alarm set-point. The unit is listed from 135°F to 174°F. However as the temperature setting increases, the spacing decreases. Alarm set-point RHA Spacing 135 to 170 OF (57 to 76 °C) Max. 50 ft 171 to 174°F(77to79°C) Max. 15 ft Features Adjustable fixed 135° to 174° Fahrenheit Rate of rise feature with 10-12°F per minute detection LEDs for 360° viewing Low profile Reliable detection technology panel. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. Specifications Item FHA Working voltage range 22.0 to 24.(,V Standby current (325 ttA Alarm indicator 2 LEDs Alarm indicator current 1.2 mA D.C.) Alarm set-point range 135 to 174 OF/ 57 to 79 °C Rate-of-rise 12 to 15°F Installation temperature range 32 to 100 °F / 0 to 38 °C Operating relative humidity range 0% to 93% (Non-condensing) Start-up time Max. 1 sec. Maximum number of addresses per loop 127 Maximum number of lighted indicators in alarm per zone. 13 Color Eggshell White Weight (without base) 73g (2.570z) Dimensions (without base) Height: 1.50 in (38mm) Diameter: 4.0 inches (99mm) Approvals / Listings UL, ULC, CSFM, MEA The system has a maximum of 13 LEDs that can be turned on simulta- neously. If the system already has 13 LEDs on, the RHA will operate even though the LED will not illuminate. Setting the Address Each addressable module, smoke sensor, heat detector and combination sensor/detector must have the address set before connecting the device to the SLC loop. The address is set using the I and held device programmer or the addressing feature on the control Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-240-1870 Tech Support: 866-956-1211 • Canada: 888-882-1833• www.pottersignal.com PRINTED IN USA MKT. #8830018- REV C PAGE 1 OF 2 06113 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING — BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. L7270-0328öTi Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: (erEiISignal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN [Mod&s'FHA andHA heat detector Model FHA is a 135-185 F fixed temperature heat detector and Model RHA is combination 15 °F rate-of-rise and 135-174 °F fixed temperature heat detector. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: FHA: 135-185 °F fixed temperature RHA is combination 15 °F rate-of-rise and 135-174 °F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed as heat detector for use with model AB-4, AB-6, AIB, ASB orARB bases and separately listed compatible fire alarm control units. 12-23-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 ListingExpiesVunejO, 2O Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Addresable Pull $taton (DPOTTE R APSSA/DA The Symbol of Protection Sin 0 gle/Duat Action Features Single or Dual Action versions Durable die-cast construction Reset key matches the fire alarm control panels ' Compatible with all PFC-6000. PFC-8000, and P Series panels 4 ' Product includes a 5 year warranty Stock Numbers APS-SA Addressable Pull Station, Single Action - 1430810 APS-DA Addressable Pull Station, Dual Action 1430811 - c®us LISTED 7150-0328:0201 S25236 Application The APS-SA/DA is compatible with Potter's PFC-6000 series and PFC-8500 addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dual action model and installs on a single box or surface mounts using the P32-BB or P32-DBB (deep) back box. Description The APS-SA (Single Action) is activated by simply pulling the white "T" bar handle down. The APS-DA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset theAPS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re-secure the front cover. Technical Specifications Operating Voltage 22.0 —24.0 VDC Max SLC Standby Cunent (0.325mA) Max SLC Alarm Current' (0.325mA) 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" Hx3.25"Wx 1.75" D Relative Humidity Range 0 - 93% (non-condensing) Single gang box or Mounting Options Potter P32-BB/DBB APS-SA - 1.22 lbs. Shipping Weight APS-DA- 1.46 lbs. . Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830052-REVB • 10/14 PAGE 1 0F2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7i5O-0328:020) Page 1 of 1 CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: otterElectrlSignaI Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignaI.com DESIGN: od&sAPSSAngleactionanAPS DA dual action addressableuU bj Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed addressable pull boxes for use with separately listed and compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 02-06-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 (Listing Expires (June 3O,öi6 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division S Po1Tr ERG /v ISCM-4 The ,cvmhnl of Protection -J .. -. ..JiII5I U .'JII (.CLU I VI (JU UI C Features One Class B (Style B) contact monitoring input Powered directly from 2 wire SLC Loop SLC Class A (Style 6,7) & Class B (Style4) Mounts on a standard 4" or double gang box Wiring terminals accessible when mounted in box Wiring terminals accept 22 to 14 AWG Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke detectors. Stock Number: 1430821 LL_W 0 o J I ZrNO C I 1 0 0! 10 c®us USTED S2930 7165-0328:0196 Application The SCM-4 is compatible with Potter's PFC-6000 series and PFC- 8500 addressable fire alarm control panels. The SCM-4 is a contact monitor module used to supervise a circuit of dry contact input devices such as; sprinkler water flow, valve tamper switches or conventional pull stations. Description The SCM-4 module uses one (1) address on an SLC loop. The module is used to supervise a Class B circuit of normally open, dry contact input devices. The SCM-4 module includes one red LED to indicate the modules status. In normal condition, the LED flashes when the device is being polled by the control panel. When a device is activated, the LED will light continuously. In case of an open circuit, the LED will turn off. Technical Specifications Operating Voltage 22.0-24.OV Max SLC Standby Current (325 tiA) Max SLC Alarm Current (imA) Max Wiring Resistance of IDC 100 Max WiringCapcitance of IDC 1jiF EOL Resistor 5.1K12 Max no. of SCI on SLC loop in ClassA 64 Units Operating Tempurature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Modules per Loop 127 units Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm) Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs . Potter Electric Signal Company LLC • St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 88300L)6-REVD • 7/14 PAGE 1 OF 2 e POTTER* MC-HMf ( M-41 The Symbol of Protection ft 1.q 1 (7i ntfTt7fii71iile Features Single module with dual contact monitoring inputs 0 Two (2) Class B or one (1) Class A monitoring inputs SLC Class A (Style 6.7)& Class B(Style4) . U J I Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 14 AWG cj Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke C2 z 1,T CI - -, detectors. 0 J L. U Stock Number: 1430822 A. LISTED S2930 7165-0328:0196 Application The DCM-4 is compatible with Potter's PFC-6000 series and PFC- 8500 addressable fire alarm control panels. The DCM-4 is an interface module used to monitor dry contact devices such as sprinkler water flow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. Description The DCM-4 uses two (2) consecutive SLC loop addresses when monitoring two (2) Class B circuits or one (1) address when monitoring a single class A (Style D) circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterfiow and valve tam per switches when they are located in the same proximity. The DCM-4 includes one red LED to indicate the modules status. In normal condition, the LED flashes when the device is being polled by the control panel. When a contact is activated, the LED will light continuously and in case of an open circuit, the LED will turn off. Technical Specifications Operating Voltage 22.0-24.OV Max SLC Standby Current (325 pA) 'Aux Power Required) (lmA) Max Wiring Resistance of IDC 100 ) Max Wiring Cpacitance of IDC 1 p.F EOL Resistor 5.1K Il Operating Tempurature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per Loop 127 units (Class A) or 63 units (Class B) Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs S . Potter Electric Signal Company LLC • St. Louis. MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 8830008-REVB • 7/14 PAGE 1 0F2 Porr riwFOA 'w km--J~ The Symbol of Protection Twin Relay Module Features - -- r Two (2) Isolated Sets of Form C Contacts Powered directly from 2-wire SLC loop. No additional power required. . o SLC Class A (Style 6,7)& Class B(Style4) Mounts on a standard 4" or double gang box Wiring terminals accessible when mounted in box - -- - Wiring terminals accept 22 to 14 AWG • Product includes a 5 year warranty W12 CP . W37 W11 G1 M1 Number: Stock 1430824 10 ce us LISTED S2930 7165-0328:0196 Application The TRM4 is compatible with Potter's PFC-6000 series and PFC- 8500 addressable fire alarm control panels. The TRM-4 is a relay module that is programmed to activate in correlation with initiating devices, such as detectors and pull stations. The TRM-4 can be used for applications such as elevator recall, AHU shutdown, or where general purpose relays are needed. Description The TRM-4 module uses one (I) address on an SLC Loop. The module has two (2), Isolated Form C relay contacts that transfer simultaneously when the device is activated. The TRM4 module includes one red LED that flashes when the device is being polled by the control panel. Technical Specifications Operating Voltage 22.0-24.OV (Max SLC Standby Current) 325 [LA) (Max SLC Alarm Current (imA) Contact Output Style Two (2) Form C Contact Rating (Resistive) 2A @ 24 VDC / 0.5A @ 125 VAC Operating Tempurature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Modules per Loop 127 units Dimensions 4.17" (106mm)L x 4.17" (106inin)W x 1.14" (29mm) Mounting Options Double Gang Box Standard 4" Square or Shipping Weight 0.6 lbs S S Potter Electric Signal Company LLC • St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 8830005 -REVD • 7/14 PAGE 1 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (§ LISTING No. CiTiJ Page 1 of 1 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Models PFC- 8060, PFC-8060/230, PFC-8500 and PFC-85001230 fire alarm control units. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PFC-8000: Power Supply ALE-127: Loop Expander Board 3005013, 3005012: EOL Resistors LCD-AN, LED-AN: Remote Annunciators CIZM4: Smoke Detector Module SCI: Loop Powered Short Circuit Isolator MCM:Miniature Contact Module DCM-4: Loop Powered Contact Modules) TRM-4: Twin Relay Module) 9M-4: Monitor Output Modul 0 RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Units meet the requirements of UL Standard 864, 9th edition. 04-11-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date issued: July 01, 2015 iitingExs (June 30, 20) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 4s (E)POTTER SELELECA2DELA The Symbol of Protection CEILING MOUNT Features Nominal voltage 24 VDC Tamperproof field selectable candela options 15, 30, 75, 95, 115, & 150 Super-Slide' Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification * • Synchronize strobe and/or horn with Gentex AVSM Control Module S® LISTED S3247 Product includes a 5 year warranty Prewire entire system, install mounting bracket, then install signals Documented lower installation and operating costs Input Terminals 12 to 18AWG Switch Selection for High or Low dBA Switch Selection for 2400Hz or mechanical Tone Switch Selection for Continuous or Temporal 3 Tamperproof re-entrant grill Surface mount with the CLNGBB (Ceiling Surface Mount Back Box) Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) Faceplate available in red or off-white Operating Temperature: 32°F to 120°F (0°C to 49°C). The CS Series is not listed for outdoor use. Unit Dimensions 6" (15.24 cm) x2.6" (6.604 cm) Description The Potter CS/CHS Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The CS/CHS offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The CHS horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone. All tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the temporal three alarm mode. The CS Series has a very minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. The Ceiling Mount Series comes standard with the 4" mounting plate which incorporates the popular Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The CS/CHS also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw without removing the signal. The CS Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use with fire protective systems. PotterElectric Signal Company, LLC.Sm.Louis,M063042 USA•CustService:866-572-3005 -Tech Support: 866-956-0988. Canada888-882-1833.wwwpottersignal.com PRINTED IN USA MFG. #8830051 -REVA PAGE 1 OF 4 06/13 CYCHS SELECTABLE CANDELA.(E)POTTER The Symbol of Protection CEILING MOUNT CS Series 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela CS-24R 4890020 24 VDC 15, 30, 75, 95, 115, 150 Cs-24w 4890021 24 VDC (15, 30, 75, 95, 115, tso) CS-24PR 4890022 24VDC 15,30,75,95,115,150 CS-24PW 4890023 24 VDC 15, 30, 75..95, 115,150 CHS Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA @ 10 ft. perANSL'UL 464 In Anechoic Room dBA @ 10 ft. CHS-24R 4890040 24VDC 15, 30, 75, 95, 115, 150 81-86 90 (CHs-241W 4890041 24VDC (15, 30, 75, 95, 115, 150) 81-86 90 CHS-24PR 4890042 24 VDC 15, 30. 75. 95, 115, 150 81-86 90 CHS-24PW 4890043 24 VDC 15, 30, 75. 95, 115. 150 81-86 90 Model Designations: C = Ceiling Mount S = Strobe HS = Horn/Strobe R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non-returnable. 74 Product Strobe Current Ratings (mA) Candela (15cd (30 cdj (75cd (95cd 115 cd (150cd '24 VDC 24 VDC c72mA (101)mA (167mA 2006A 214 mA c286mnA UL Max' 120 mA 120 mA 200 mA 220 mA 290 mA 321 mA 1lProdm';Horn Decibel and Current Ratings (mA) Horn Mode Minimum dBA@ lOft. per ANSI/UL 464 (HIGH) Minimum dBA@ 10 ft. per ANSI/UL 464 (LOW) Regulated 24 VDC Max. Operating @ High Setting (mA) Temp 3 2400Hz 83 75 23) Temp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 15CDH/S 72+23MA= 95MA 30CD H/S 101+23= 124ma 75CD H/S 167+23= 190ma S NOTES: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the mammum listed voltage. For unfiltered FWR ratings, see installation manual. Potter-Electric Signal Company, LLC. St. Louis,MO 63042 USA•CustSeivice:866-572-3005.Tech Support: 866-956-0988. Canada888-882-1833.wwwpouersignal.com PRJNEDNUSA MFG. #S830051 -REVA PAGE 3OF4 06/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. Ll f51-6569 =-1 23 eifl) AlGôR' 125--flREALARMiDEVICES FOR THE HEARING IMPAIRED LISTEE: Gentex Corporation 10985 Chicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestricgentex.com DESIGN: Models ST24-15, S124-15175, ST24-30, S124-60, ST24-75, ST24-110,_GES24-15, GES24-15175, GES24-30, GES24-60, GES24-75, GES24-110, GE4-177 and GES3-24 strobe lights; followed by suffix -W (wall mount), followed by -W or -R (white or red). Intended for indoor use and wall mount only. Model CS-24 strobe lii followed by W or R (white or red color) and P (plain). For indoor use on wall or ceiling mount. Model AVSM Sync Module intended for indoor use with Gentex synchronizable strobe lights. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Candela: 15cd, 15cd & 75cd at 00 angle axis 30cd, 60cd, 75cd, ll0cd, 177cd. Model G( Selectable 15cd, 30cd, 75cd, 95cd, 115cd, and *150cd Model GES3-24: Selectable 15cd, 30cd, 60cd, 75cd and 110cd. Electrical: 21-30 VDC Model AVSM: 8-33 VDCNFWR Flash Rate: 60 flashes per minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical and candela ratings and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 09-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires 30, 2016) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division (E)POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela, Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) S-24WR 4890010 24 VDC 15, 30, 60, 75. 110 S-24WW 4890011 24 VDC 15, 30, 60, 75, 110 HS-24 24 VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) Reverberant dBA at 10 ft., per ANSI/UL 464 In Anechoic Room dBA at 10 ft. HS-24WR 4890030 24 VDC 15, 30, 60, 75, 110 62-82 100 HS-24WW 4890031 24 VDC 15, 30, 60, 75, 110 62-82 100 S-24 & HS-24 Product Strobe Current Ratings (mA) S 24 VDC(16-33 Volts) Candela 24 VDC UL Max' 15 c 3O mA 42 mA 30 c 35 mA 58mnA 60 c 66 mA 97 mA 75 c 8O mA j 116 mA hOed 103 mA 1 161 mA S-24 & HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Mode Minimum SPL at 10 ft., per ANSI/UL 464 (HIGH) Minimum SPL at 10 ft, per ANSI/UL 464 (LOW) Regulated 24 VDC Max. Operating @ High Setting (mA) Temp 3 2400 Hz 78 dBA 71* dBA 28 mA Temp 3 Mechanical 76 dBA 70* dBA 25 mA Temp 3 Chime 70* dBA 66* dBA 15 mA Continuous 2400 Hz 81 dBA 74* dBA 28 mA Continuous Mechanical 80 dBA 72* dBA 25 mA Continuous Chine 70* dBA 66* dBA 15 mA Whoop 82 dBA 69* dBA 56 mA St hs 15cd 30 58ma 30cd 35 63ma 75cd 80 108ma 110cd 103 131 ma Model Designations: W = Wall Mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non-returnable. ALERT bezel available for order ALERT bezel available for order NOTES: For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. Potter does tito recommend usign a coded or pulsing signaling circuit with any of our strobe products. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). PotterElectricSignalCompanv,LLC. St. Louis,MO 63042 USA•CustSeivice:866-572-3005 -Tech Support: 866-956-0988. Canada888-882-1833.www.pottersignaLcom PR.II'JTED IN USA 34FG. 48830054 -REV A PAGE 3 OF 4 06113 CALIFORNIA DEPARTMENT OF FORESTRY& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. C7 71921 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Gentex Corporation 10985 Chicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestricgentex.com DESIGN: Model GEH24 horn and Modelsj-I415, HS24-15175, H524-30, HS24-60, H524-75, H524-110, GEC24-15, GEC24-15175, GEC24-30, GEC24-60, GEC24-75, GEC24-110, GEC24-177, GCC24-C, GEC3-24 and WGEC24 horn strobes. May be followed by -W (wall) and -W or -R (white or red) or-P plain. Models GCC24-C horn/strobe are ceiling mounted followed by -R (red), -W (white) or -P (plain). Refer to listee's data sheet for additional product description and operational considerations. RATING: Electrical: 24 VDC Candela: 15cd, 15/75cd, 30cd, 60cd, 75cd, 110cd, 177cd. GCC24-C Ceiling: 15cd, 30cd, 75cd, 95cd, 115cd, 150cd* (selectable) GEC3-24 Wall: 15cd, 30cd, 60cd, 75cd, 110cd (selectable) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings and UL label. . APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control units. For indoor use only. Model WGEC24 is intended for outdoor use when used with Model GOE outdoor enclosure (CSFM Listing No. 7300-0569:124). Model WGEC24 is intended for private mode signaling use only and not approved for hearing impaired application. The audible in Models GEH24, GEC24, GEC3-24, and WGEC24 may produce distinctive tones including: mechanical, 2400Hz and chime tones in continuous and temporal 3 settings as well as a whoop tone in either a high or low dBA setting. The audible in Model HS24 may produce a horn piezo frequency of 31001-1z. Model GCC24 may produce distinctive tones including mechanical and 24001-1z. Both models are capable of continuous and temporal 3 settings. Rev. 09--26-14jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 (Listing Expires ) Gi3O,2016) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division UO!S!/t!O 5U!J0Ui6U3 J'd JoJewpJoo weJ50Jd 'NVI3SdVd s3hvvr AS pzuoqn salldx3 5uqs io 'io Ajng' panssi wa ieqo ioipue SUO!OflJSU! uo!eflesui 'aaqs Bep s,eals!l ol .1ejaJ eu3uO UoeflesUI JO SUewaJ!nbeJ Ieuo!e.Iedo J!Jaf ol pasn 9q 10U pnoqs 6u115!I Sll4j pa4S!I wet! aqj jo uoijepuawwooeJ JO juawasiopue ue ou S! 6uisii s1qJ sw!ep Aue jo uoieoijua apuadapui ue aew ou seop nq eep J84O JO/pue sinsai S4 LU P8M9IA8J seq jjep 6uueeu!6u3 OJIJ VIdS3 ueoiidde a44 Aq paiwqns e;ep leoppal uodn peseq si 6u!s!l siqj 46 P I-CO-60 Aed, SI!840p jol lenuen U0Q0fl.4SUI uoi4eesu SSIJ OT Je48I S!Ufl I0J4UO3 WJRB aJIJ apledwoo psi AIe4eJedos q4!M asn JO4 peJiedwi 6uueeq aqj jol eqe4ins sq6ip eqois SB O4Sfl :1yA0Jddy oqei in pue s6uiei eiepueo pue 1e0u40e18 'Jeqwnu IPoW 'ewBu S884Sfl 9NI)4I\fi UO!43!pSufli 5uiAeq A4iJOq4ne eqj 04 eqB4deooe jauuew e U! PUB Se3Ueu!pio PUB S9P03 eiqeoidde 'SUO!43flJ4SUi uOLjCIIB4Sui pe4U!Jd Se4Sfl q4iM eouep000e U 04flU!W jad seqse 09:94B8 qsej JMdNOGA -9 :ASAV 19POIN OGA OC-2 :leu43aI3 P°014 PUB pogL 'P09 'P0C p091. eqe4oee :t7Z-CS39 leP0U' P0091.. PUB 'P914 'P396 'PçL 'P00E 'P091. OIB4Oe9 :j5o japoj POLL 1. 'P°OH. 'P°9L 'PO9 'PO0 sixe e6UB 00 48 PO9L ' p09i. 'poç. :elepUeo :9jI1yj SUOD,eJep!SUOO jeUO!4eJedO PUB UO!4d!J0Sep 4onpoJd Pei!e4eP leuoilippe Jo4 eeqs eep S,ee4S!I 04 eeI si!i eqojs eqBz!UoJqouAs xeueo qiM esn JoopUl lol papUOUI eflpovj OUAS INSAV lopon 4UflOW U!l!0 JO IIM UO asn JOOpU! JoJ (u!Bld) d PUB (Joloo pei io e4iqM) 4q_peMoljo4)4q!IeqoJ4s -s5)iepovij Aiuo jUflOW IBM pue esn JOOpU! J04 P0PU4UI (poi .o 04!qM) èj- io M- Aq PeMoIlo4(4Uflow IBM) M- XV4flS Aq PMOHO4 S4Ll!I eqos PUB 1.-t7S2O '01.1-17S90 '9L-ts90 '091,699 '0 -tS '9119 1.-iSO 9I.-117S0 '0I.1.-i7.LS '9L-1IS '09-iis '0E-t!S '9L19I.-t'1s '-ij :N9Is3a wooxe4ue6)0!J4sasJeI4!e)I :I!ew 6I.P-6c (91.9) xezl 96I.L-6 (91.9) o!J4s9s 4!)i :40e4u03 P9ii6t IVY PUeIZ 'eA!Ja 06e014 9960 I. uOqeJOdJo X84U09 :331Sl1 aaeiivi; ONIVH 3H1èIOd soIAa IV1VHd -- 91.L :0031I3 1.4° 1. e68d (oco-I T, •°N ONIISI1 23IALS ONIISI1 to VlIVIOOHd ONI1S11 S1VId31VVii ONIO1Ifl9 - NI113NI9N3 3JII 1VHSH YIN 3II1 31Y.LS 3H1 JO 331I0 N0I133101d 38IJ V ANIS3HOJ JO 1N3ViI.LJYd3U VINd0JI1V) P POTTER (s24-1ñiH7) ia .2 P 2 tm n 1-Girn ctr,i p I tie oy,1IUuIuI rfuwt,iiuii '-"-'- 0 Features Nominal Voltage 24 VDC Fixed 177 candela strobe \'\ Super-Slide® Bracket - ease of supervision testing Checkmate® - Instant voltage verification - Unit Dimensions: 5" (12.7 cm) high x 4.5" (11.43 cm) wide x 2.5" (6.35 cm) deep. Synchronize strobe and/or horn with AVSM Control Module j Pm wire entire system, install mounting bracket, then install signals Documented lower installation and operating costs . . .. Lk Input terminals 12 to 18 AWG Switch selection for high or low dBA Switch for chine, whoop, mechanical and 24001-lz tone Switch for continuous or temporal 3 (not available on whoop tone) SI(NAUNG Tamper proof re-entrant gnu Surface mount with the AV-BB UL Silence horn while strobes remain flashing LISTED _______ _________ Faceplate available in red or off-white S3247 (i-0328:O2i7(HS24-i7) V 125-0328:02.16 (S24-177J Applications The S/H524-177 Series is a low profile strobe, or horn/strobe combination that offers dependable audible and visual alarms with the absolute lowest current available. The S/HS24-177 Series has a minimum flash rate of 1Hz regardless of input voltage. The S/HS24-177 Series is shipped with the standard 4" mounting plate which incorporates the popular Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The S/H524- 177 Series also features the patented Checkmate® -Instant Voltage Verification feature which allows the installer to measure the voltage drop and match it to the blueprint. The S/HS-177 Series appliances are ANSI/UL 464, ANSI/UL 1971 and/orANSL'UL 1638 listed for use with fire protective systems and are warranted for five years from date of purchase. Product Listings ANSI/UL 464, ANSI/UL 1971 and/or ANSI/UL 1638 Listed Product Compliance NFPA72 Americans with Disabilities Act (ADA) IBC/IFC/IRC City & State Ordinances/Laws/Regulations Quality Management System is certified to: 150 9001:2008 0 Potter Electric Signal Company LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com PRINTED INUSA MFG.98830066-REVA • 5114 PAGE IOF4 I E Model Designations: P = Plain (no lettering) R Red faceplate W = White Faceplate. Plain units are non-returnable. Alert Bezel Available: Red - 4890264 White - 4890265 Agent Bezel Available: Red - 4890262 White - 4890263 HS-24 Horn Decibel and Current Ratings Minimum dBA Minimum dBA Regulated 12VDC @lOft.per @lOft.per Horn Mode Max. Operating @ ANSI/UL464 ANSIJUL464 P.-. -, High Setllng(mA) (HIGH) (LOW) Temp 3 Mechanical 76 70' 25 Temp 3 Chime 70* 66' 15 Continuous 2400Hz 81 74' 28 Continuous Mechanical 80 72' 25 Continuous Chime 70* 66* 15 Whoop 82 69* 156 177cd st = 213ma 177cd his = 241 ma 24VDC (16-33 Volts) Candela 24 VDC UI. Max' ALI 77cdJ 96mA 13rnA) S (E)POTTER The Symbol of Protection S24-1 77/HS24-1 77 !-lkrh Candela Strnhe and Horn/Strobe 524-177 VDC Low Profile Evacuation Strobe Model Nuin her Item Number Nominal Voltage Strobe Candela S24-177R 4890014 24VDC 177 S24-177W 4890015 24VDC 177 S24-177PR 4890016 24VDC 177 S24-177PW 4890017 24VDC 177 HS24-177 24 VDC Fixed Candela, Low Profile Evacuation Horn/Strobe Model Number Item Number Nominal Voltage Strobe Candela Reverberant dBA @ loft., perANSuul. 464 In Anechoic Room dBA@ loft. HS24-177R 4890034 24VDC 177 70-82 100 HS24-177W 4890035 24VDC 177 70-82 100 HS24-177PR 4890036 24VDC 177 70-82 100 HS24-177PW 4890037 24VDC 177 70-82 100 S/HS24-177 Series Current Ratings (mA) NOTES.- Operating temperature: 32°to 120°F (01' to 490C). The 177 Series is not listed for outdoor use. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is tIme maximum RMS current within the listed voltage range (16- 33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. . Potter Electric Signal Company, LLC St. Louis, MO • Tech Support: 866-956-0988 I Customer Service: 866-572-3005 www.pottersignal.com PRINTED IN USA MPG. #8830066 - REVA • 5/14 PAGE 3 OF 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM to LISTING SERVICE LISTING No. 7125-O569:012) Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Gentex Corporation 10985 Chicago Drive, Zeeland, Ml 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestric©gentex.com DESIGN: ls S124-15, ST24-15175, ST24-30, ST24-60, S124-75, ST24-110, GES24-15, GES24-15175, GES24-30, GES24-60, GES24-75, GES24-110, GE1 and GES3-24 strobe lights; followed by suffix -w (wall mount), followed by -w or -R (white or red). Intended f for indoor use and wall mount only. ModeItGCS-24strob,light;(folIowed_byor R (white or red color) and P (plain). For indoor use on wall or ceiling mount. Model AVSM Sync Module intended for indoor use with Gentex synchronizable strobe lights. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Candela: 15cd, 15cd & 75cd at 00 angle axis 30cd, 60cd,75cd, llOcd, 177cd. Model GS2'4: Selectable 15cd, 30cd, 75cd, 95cd, 115cd, and *150cd Model GES3-24: Selectable 15cd, 30cd, 60cd, 75cd and 110cd. Electrical: 21-30 VDC Model AVSM: 8-33 VDCNFWR Flash Rate: 60 flashes per minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical and candela ratings and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 09-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2015 Listing Expires 3O,2O1) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division (E)POTTER Th ,rnhn! ,if Prntpptinn Outdoor Strobes and Horn/Strobes Outdoor S/HS-WP Series S3247 Product Listings ANSI/UL 464 and 1638 Complies with American with Disabilities Act (ADA) Complies with IBC / ITC / IRC Technical Specifications Operating Voltage Nominal 24VDC (16-33VDC) Operating -31°F - 150°F (-35° - 66°C) Temperature LP Version - 5.75" H x 4.75" W x 3.25" D Dimensions Standard - 5.75" H x 4.75" W x 4.18"D Wiring Connections Terminals accept 18 - 12 AWG LP Version - Single gang, double gang, or 4" square back box Mounting Standard Version - Surface mount back box included Shipping Weight 2.05 lbs. 0 - I I II! IJJ III lit/I IJI I I liltililIlil I Features Fixed 75cd strobe cludes the WPBBsurfij-rnount (standard) or WPLPBB Low Profile (LP) enclosure WPBB/LP made of clear Lexan® - provides maximum visibility and reliability, allowing full 75cd output Super-Slide® Bracket — Ease of supervision testing Checkmate® - Instant voltage verification Synchronize strobe and/or horn with AVSM module Switch selection for high/low dBA Switch for chime, whoop, mechanical, and 2400Hz tone Input terminals accept 18 to 12 AWG Switch for continuous or temporal 3 tone (not available on whoop) Tamperproof re-entrant grill 5 year warranty 1 1 - I' 'U LPVersion Standard SIGNALING LISTED 0 Application The SIHS-WP Series Outdoor Signals are wall mount, low profile strobes and horn/strobes that offer dependable audible and visual alarms for warning and emergency notification in outdoor locations. Description The S/HS-WP Series Outdoor Signals are 24VDC strobes and horn/ strobes equipped with a fixed 75 candela strobe. This series of outdoor signals are available in two different versions. The standard version includes a surface-mount back box (WPBB) to install directly on a wall. The Low Profile (LP) versions includes a low profile back box (WPLPBB) designed to be installed on a flush- mounted electrical box. The weatherproof enclosure is made of clear Lexan® which provides maximum visibility and reliability for effective visible signaling, allowing full 75cd output. The S!HS-WP series strobe has a minimal operating current and a minimum flash rate of 1Hz regardless of input voltage. The strobe is synchronized using Gentex sync. protocol ortheAVSM Sync. Module. The SIHS-WP Series is equipped with a universal 4" mounting bracket which incorporates the popular Super-Slide® feature that allows the installer to easily pre-wire the system and test for supervision. The product also features a locking mechanism that secures the signal to the bracket without showing any screws and the Checkmate® - Instant Voltage Verification Feature which allows the installer to check the voltage drop, current draw, and match against the blue print. S Potter Electric Signal Company LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830057-REVE • 3/15 PAGE 10F4 (E)POTTER Th umhn! nf Protp'inn Outdoor Strobes and Horn/Strobes S/HS-WP Series S-24-WP, 75 Candela, Outdoor Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color WP Enclosure S-24WR-WP 4890050 Red Standard S-24WW-WP 4890051 Off-White Standard S-24PWR-WP 4890052 Red-Plain Standard S-24PWW-WP 4890053 Off-White-Plain Standard SLP-24WR-WP 4890054 Red Low Profile SLP-24WW-WP 4890055 Off-White Low Profile SLP-24PWR-WP 14890056 Red-Plain Low Profile SLP-24PWW-WP 1 4890057 Off-White-Plain Low Profile Model Designations = Wall Mount = Red Face Plate "W"—Off - White Face Plate "P"= Plain (Note: Plain units are non-returnable) "LP"= Low Profile (WPLPBB Enclosure) Strobe Current Ratings Candela 75 cd 24VDC 112rnA (UL Max) (170 mA) NOTE: ForunfilteredFWR ratings, see installation manual. S HS-24-WP Series, 75 Candela, Outdoor Horn /Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color Reverberant dBA at 10', per ANSI/UL 464 In Anechoic Room dBA at 10' WP Enclosure HS-24WR-WP 4890060 Red 70-82 100 Standard HS-24WW-WP 4890061 Off-White 70-82 100 Standard HS-24PWR-WP 4890062 Red-Plain 70-82 100 Standard HS-24PWW-WP 4890063 Off-White-Plain 70-82 100 Standard HSLP-24WR 4890064 Red 70-82 100 Low Profile HSLP-24WW 4890065 Off-White 70-82 100 Low Profile HSLP-24PWR 4890066 Red-Plain 70-82 100 Low Profile HSLP-24PWW 4890067 Off-White-Plain 70-82 100 1 Low Profile Horn Decibel and Current Ratings Horn Setting S Minimum dBA at 10', Per UL 464 (HIGH) Minimum dBA at 10', Per UL 464 (LOW) Regulated 24VDC Max. Operating Current, at High Setting (mA) Temporal 32400Hz 78 71* 28 Temporal 3 Mechanical 76 70* 25 Temporal 3 Chime 70* 66* 15 Continuous 2400Hz 81 74* 28 Continuous Mechanical 80 72* 25 Continuous Chime 70* 66* 15 Whoop 82 1 69* 56 *operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). I 98ma hs-24ww-wp I 70ma s24ww-wp S Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 I Customer Service: 866-572-3005 www.pottersignal.com 8830057-REVB • 3/15 PAGE 2OF4 & 1VSOc,3 . SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 11/24/15 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Nordson - Asymtek Address: 2765 Loker Avenue West, Carlsbad, CA 92010 1 Description of property: Commercial B, Si, Fl & A3 Occupancy Name of property representative: Steve Burns Address: Same Phone: 760.930.7250 Fax: E-mail: steven.burns@nordsonasymtek.co INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Nova Security Address: 8779 Cottonwood Avenue, Suite 103 Phone: 619 448-3007 Fax: 619 448-3008 E-mail: support©novasecurity.us Service organization: Same Address: Phone: Fax: E-mail: Testing organization: Same Address: Phone: Fax: E-mail: Effective date for test and inspection contract: NA Monitoring organization: Tyco/ADT Address: Phone: 800-289-2647 Fax: E-mail: Account number: H022921043 Phone line 1: Phone line 2: Means of transmission: DACT Entity to which alarms are retransmitted: Carrlsbad PD Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: Rear Fire Alarm/Equipment Room DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system 0 Modification to existing system Permit number: FA1 50050 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Potter Model number: PFC-6800 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright© 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sate or distribution. (p. 1of3) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: I20VAC Overcurrent protection: Type: Circuit Breaker Branch circuit disconnecting means location: Main Electic Room Control panel amps: 3 Amps: 20 Number: OPII CKT 23 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit 0 This system does not have power extender panels Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line B 0 Device Power B 0 Initiating Device B 0 Notification Appliance B 0 Other (specify): REMOTE ANNUNCIATORS Location RA-6500, Main Lobby by Stairs INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Addressable alarm Contact Smoke Detectors 6 Addressable Alarm Photo Duct Smoke Detectors 41 Conventional Supervisory Photo Heat Detectors Gas Detectors Waterfiow Switches 3 Conventional Alarm Contact Switch Tamper Switches 4 Conventional Supervisory Contact Switch Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2 of 3) SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 45 Potter Strobe Combination Audible and Visible 57 Potter Horn/Strobe SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices NA HVAC Shutdown 41 Fire/Smoke Dampers NA Door Unlocking NA Elevator Recall NA Elevator Shunt Trip NA INTERCONNECTED SYSTEMS This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as s ecified he em has been installed according to all NFPA standards cited herein. Signed: Printed name: Kevyn Lim Date: Organization: Nova Security Title: VP Phone: RIO AARflfl7 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: .._. Printed name: Kevyn Urn Date: Organization: Nova Security Title: VP Phone: 619 448-3007 12.3 Acceptance Test Date and time of acceptance test: I/ 5/ Installing contractor representative: Testing contractor represent Property representative: / AHJ representative: \..7Y Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. tp 3of3)