Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 101; FPC2018-0407; PermitII 1iIi[sJI cJity of Carlsbad I Mz~ff-= C ~~ Print Date: 12/13/2021 Job Address: 2525 ELCAMINO REAL, # 101, CARLSBAD, CA 92008-1204 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1563020900 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: TEXAS DE BRAZIL -CANOPY SPRINKLER TI (13 HEADS) Permit No: FPC2018-0407 Status: Closed - Finaled Applied: 12/13/2018 Issued: 01/08/2019 Finaled Close Out: 02/11/2019 Inspector: Final Inspection: Applicant: FPContractor: VFS FIRE & SECURITY SERVICES VFS FIRE AND SECURITY SERVICES SALVADOR JASSO 501 W SOUTHERN AVE 501 W SOUTHERN AVE ORANGE, CA 92865-3217 ORANGE, CA 92865-3217 (714) 778-6070 (714) 919-8351 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov FIRE & SECURITY SERVICES VFS FIRE AND SECURITY 501 W. SOUTHERN AVE. ORANGE, CA 92865 714 778 6070 Job Name : TEXAS DE BRAZIL CANOPY Building : FP-1 Location : 2525 EL CAMINO REAL System AREA 1 Contract : 183167 Data File CANOPY HYD.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 o 01 oco 0)0 O Q Ir uJ <c1 wo) a.. >- 0 LL o9 o z< 9 -J 00 Of o c1 uJ 0 UL I') VFS FIRE AND SECURITY Page 1 TEXAS DE BRAZIL CANOPY Date HYDRAULIC CALCULATIONS for Project name: TEXAS DE BRAZIL CANOPY Location: 2525 EL CAMINO REAL Drawing no: FP-1 Date: 12/11/2018 Design Remote area number: AREA I Remote area location: SYSTEM 1 Occupancy classification: L. H Density: .10 - Gpm/SqFt Area of application: ENTIRE - SqFt Coverage per sprinkler. 175- SqFt Type of sprinklers calculated: SSU GL5615 K=5.6 Q/R 200 DEGREE No. of sprinklers calculated: 13 In-rack demand: N/A - GPM Hose streams: 100-GPM Total water required (including hose streams): 374.95 -GPM @ 79.049 Psi Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 04/05/2017 Location: HYDRANT H60994 Source: CITY OF CARLSBAD Name of contractor: VFS FIRE AND SECURITY Address: 501 W. SOUTHERN AVE. I / ORANGE, CA 92865 Phone number: 714 778 6070 Name of designer: SAL JASSO Authority having jurisdiction: CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) 10% REDECUCTION 10% REDECUCTION FROM ORIGINAL PRESSURES. Computer Programs by Hydratec Inc. Revision: 50.53.5 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: The Shoppes at Carlsbad SRU: PROJECT ADDRESS: (Assigned upon plan submittal) CITY: Carlsbad PHONE: ( 714) 778.6070 (VFS Fire & Security Services) FAX NUMBER: Largest Building (ft.2 Sprinkled? Construction Type:_________________ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY, CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Marron Road west of Plaza Dr. (Westfield Plaza) TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 92 PSI Hydrant Number (if applicable):H60994 Elevation of test: 43 Feet Dat me of Test1: Pito Tube ReadIngs_______________ PSI Coicsponding Flow ________ 6PM Total Flow: 6,050 GPM Residual Pressure 42 PSI Atpeakdemand this water system is capable of providing a fire flow discharge at 20 psi of 7,350 gpm. However, this exceeds the District's maximum velocity criteria of 15 fps. Therefore, the maximum allowable fire flow for this site is 6,050 gpm. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R,Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: Title/Org: Pj 'I_CtManager Date: 04/05/2017 Water Supply Curve C VFS FIRE AND SECURITY Page 2 TEXAS DE BRAZIL CANOPY Date City Water Supply: Demand: Cl - Static Pressure : 82.8 Dl - Elevation : 9.961 C2 - Residual Pressure: 37.8 D2 - System Flow : 274.95 C2 - Residual Flow : 6050 D2 - System Pressure : 79.049 Hose ( Demand) : 100 - D3 - System Demand : 374.95 Safety Margin : 3.489 150 140 130 p120 - R11° -- E10° S 90 r s 80 u7OD R 60 50 --- 40 30 20 10 -- t,A ......... I ......... I - I I I I I I I 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Flow S.ummary - NFPA VFS FIRE AND SECURITY Page 3 TEXAS DE BRAZIL CANOPY Date SUPPLY ANAL YSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure CON 82.8 37.8 6050.0 82.538 374.95 79.049 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 19.0 5.6 9.77 17.5 HD3 19.0 5.6 9.77 17.5 1 19.0 5.6 10.93 18.51 1A 19.0 5.29 10.93 17.5 2 19.0 5.6 11.06 18.63 2A 19.0 5.29 11.09 17.62 3 19.0 5.6 11.86 19.29 3A 19.0 5.29 11.86 18.23 4 19.0 5.6 12.93 20.14 5 19.0 5.6 12.97 20.17 6 19.0 5.6 13.24 20.37 7 19.0 5.39 20.96 24.69 8 19.0 5.39 21.16 24.81 12 19.0 21.29 9 19.0 5.39 22.52 25.59 13 19.0 5.39 29.72 • 29.4 10 19.0 12.02 11 19.0 13.29 14 19.0 29.88 15 19.0 40.98 16 19.0 63.06 47 19.0 63.25 48 19.0 63.55 113 19.0 63.66 TRS 4.0 70.3 BRS 2.0 71.22 UG -4.0 73.86 UG1 -4.0 73.96 UG2 -4.0 73.97 DC1 -4.0 73.97 DC2 -4.0 79.03 CON -4.0 79.05 100.0 K=K @ HD2 K=K @ HD2 K=K @ HD2 K=K @ HD4 K=K @ HD4 K=K @ HD4 K=K @ HD4 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations:, Hazen-Williams VFS FIRE AND SECURITY Page 4 TEXAS DE BRAZIL CANOPY Date Nodel Etevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf HD1 19 5.60 17.50 1 2E 4.0 2.500 120 9.766 to 1 5.0 9.000 0.0 HD2 19 17.5 1.049 0.0 11.500 0.1017 1.169 Vel = 6.50 P.O HD2 17.50 10.935 K Factor= 5.29 HD3 19 5.60 17.50 1 E 2.0 0.500 120 9.766 to T 5.0 7.000 0.0 HD4 19 17.5 1.049 0.0 7.500 0.1016 0.762 Vet = 6.50 0.0 HD4 17.50 10.528 KFactor = 5.39 1 19 5.60 18.51 2 0.0 2.625 120 10.926 to 0.0 0.0 0.0 1A 19 18.51 2.157 0.0 2.625 0.0034 0.009 Vet = 1.63 IA 19 5.29 17.50 2 0.0 11.167 120 10.935 K=K@HD2 to 0.0 0.0 0.0 2 19 36.01 2.157 0.0 11.167 0.0115 0.128 Vet= 3.16 2 19 5.60 18.63 2 0.0 0.875 120 11.063 to 0.0 0.0 0.0 2A 19 54.64 2.157 0.0 0.875 0.0251 0.022 Vet = 4.80 2A 19 5.29 17.62 2 T 12.307 10.042 120 11.085 K=K©HD2 to 0.0 12.307 0.0 10 19 72.26 2.157 0.0 22.349 0.0419 0.936 Vet = 6.34 0.0 10 72.26 12.021 KFactor= 20.84 3 19 5.60 19.29 2 0.0 1.125 120 11.860 to 0.0 0.0 0.0, 3A 19 19.29 2.157 0.0 1.125 0.0036 0.004 VeI= 1.69 3A 19 5.29 18.22 2 T 12.307 0.250 120 11.864 K=K@HD2 to 0.0 12.307 0.0 10 19 37.51 2.157 0.0 12.557, 0.0125 0.157 Vel = 3.29 0.0 10 37.51 12.021 KFactor= 10.82 19 5.60 20.14 2 . 0.0 11.167 120 12.929 to 0.0 0.0 0.0 5 19 20.14 2.157 0.0 11.167 0.0039 0.044 Vet = 1.77 5 19 5.60 20.17 2 T 12.307 10.042 120 12.973 to .. 0.0 12.307 0.0 11 19 40.31 2.157 0.0 22.349 0.0142 0.318 Vet = 3.54 0.0 11 40.31 13.291 KFactor 11.06 6 19 5.60 20.37 2 1 12.307 1.125 120 13237 to 0.0 12.307 0.0 11 19 20.37 2.157 0.0 13.432 0.0040 0.054 Vel = 1.79 0.0 . 11 20.37 . 13.291 K Factor= 5.59 7 19 5.39 24.69 2 2E 12.307 21.375 120 20.9.64 K= K@ HD4 to 0.0 12.307 0.0 8 19 24.69 2.157 0.0 33.682 0.0057 0.193 Vet = 2.17 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams VFS FIRE AND SECURITY Page 5 TEXAS DE BRAZIL CANOPY Date Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 8 19 5.39 24.81 2 0.0 6.333 120 21.157 K=K@HD4 to 0.0 0.0 0.0 12 19 49.5 2.157 0.0 6.333 0.0208 0.132 Vet = 4.35 12 1.9 170.45 2 0.0 3.750 120 21.289 to 0.0 0.0 0.0 9 19 219.95 2.157 .0.0 3.750 0.3283 1.231 Vet = 19.31 9 19 5.39 25.60 2 T 12.307 6.000 120 22.520 K = K @ HD4 to . 0.0 12.307 0.0 14 19 245.55 2.157 0.0 18.307 0.4023 7.365 Vel = 21.56 - 0.0 14 245.55 29.885 KFactor= 44.92 13 19 5.39 29.40 2 T 12.307 9.000 120 29.716 K = K @ HD4 to .0.0 12.307 0.0 14 19 29.4 2.157 0.0 21.307 0.0079 0.169 Vel 2.58 0.0 14 29.40 29.885 K Factor= 5.38 10 19 109.77 2 0.0 14.000 120 12.021 to 0.0 0.0 0.0 11 19 109.77 2.157 0.0 14.000 0.0907 1.270 Vel = 9.64 11 19 60.68 2 3E 18.46 8.292 120 13.291 to T 12.307, 30.767 0.0 12 19 170.45 2.157 0.0 39.059 0.2048 7.998 Vel = 14.97 0.0 12 170.45 21.289 KFactor 36.94 14 19 274.95 2 3E 18.46 3.917 120 29.885 to 0.0 18.460 0.0 15 19 274.95 2.157 0.0 22.377 . 0.4959 11.097 VeI= 24.14 15 19 0.0 2 T 12.307 32.208 120 40.982 to 0.0 12.307 0.0 16 19 274.95 .2.157 0.0 44.515 0.4959 22.076 VeI= 24.14 16 19 0.0 6 E 17.603 18.750 120 63.058 to . T 37.72 55.323 0.0 47 19 274.95 6.357 0.0 74.073 0.0026 0.190 Vet = 2.78 47 19 0.0 6 T 30.0 34.833 120 63.248 to 2E 28.0 58.000 0.0 48 19 274.95 6.065 0.0 92.833 0.0032 0.300 Vet = 3.05 48 19 0.0 6 E 17.603 26.333 120 63.548 to 0.0 17.603 0.0 113 19 274.95 6.357 0.0 43.936 0.0026 0.113 Vet = 2.78 113 19 0.0 8 3E 63.423 108.583 120 63.661 to 3F . 31.712 95.135 6.496 TRS 4 274.95 8.249 0.0 203.718 0.0007 0.147 Vel = 1.65 TRS 4 0.0 8 G 4.698 5.000 120 70.304 to S 52.853 57.551 0.866 BRS 2 274:95 8.249 0:0 62.551 0.0007 0.046 Vet = 1.65 BRS 2 0.0 8 E 21.405 5.000 120 71.216 to T 41.62 63.025 2.599 UG -4 274.95 8.27 0.0 68.025 0.0007 0.048 Vet = 1.64 Computer Programs by Hydratec Inc. Revision: 56.53.5 Final Calculations: Hazen-Williams VFS FIRE AND SECURITY Page 6 TEXAS DE BRAZIL CANOPY Date Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf UG -4 0.0 8 0.0 114.708 120 73.863 to 0.0 0.0 0.0 UG1 -4 274.95 7.98 0.0 114.708 0.0008 0.097 Vel = 1.76 UG1 -4 0.0 8 0.0 10.000 140 73.960 to 0.0 0.0 0.0 UG2 -4 274.95 8.27 0.0 10.000 0.0006 0.006 Vel = 1.64 UG2 -4 0.0 8 0.0 5.000 150 73.966 to 0.0 0.0 0.0 DC1 -4 274.95 7.98 0.0 5.000 0.0004 0.002 Vel = 1.76 DC1 -4 0.0 8 SE 142.34 6.000 140 73.968 to 0.0 113.872 5.000 **Fixed Loss ..5 DC2 -4 274.95 8.27 0.0 119.872 0.0005 0.065 Vel = 1.64 DC2 -4 0.0 10 T 67.474 10.000 150 79.033 to 0.0 67.474 0.0 CON -4 274.95 9.79 0.0 77.474 0.0002 0.016 Vel = 1.17 100.00 Qa= 100.00 CON 374.95 79.049 KFactor 42.17 Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary VFS FIRE AND SECURITY Page 7 TEXAS DE BRAZIL CANOPY Date Fitting Legend Abbrev. Name % % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA 139O Flow thruTee . 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Flow-Diagram V F S FIRE AND SECURITY Page 8 TEXAS DE BRAZIL CANOPY Date 17.5 HDI<- HD2 17.5 HD3- HD4 18.5 54.6 I +-IA<--2 -2A-10 36 72.3 19.3 3 -3A-10 37. I 109.6 20.1 I 4 4-5 -l1 T 40. I 40,T 170.5 204 I 6 -l1 24.7 I 220 7 -8 -12 -9 -14 49.5 245.5 29.4 13 +- 14 109.8 10 .- II - 12 170.5 275 275 275 275 275 275 275 14 - 15 <_ 16 - 47 - 48 - 113- TRS- BRS<- UG - UG1- UG2- DCI<- DC2- CON 275 275 275 275 275 275 Computer Programs by Hydratec Inc. Revision: 50.53.5 QUICK RESPONSE SERIES GL-QR SERIES GL-QRiCNV UPRIGHT CONVENTIONAL NJ lff4 l) QUICK RESPONSE SERIES GL-QR SERIES GL-QRJSW PENDENT VERTICAL SIDEWALL ra i L'J L'J SHY QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response Series GL-QR Sprinklers are a low profile yet durable design which utilizes a 3mm.frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the ap- plicable standards. It offers the additional feature of greatly in- creased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used ad- visedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL-QR sprinkler proven ac- tuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the inter- nal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (790C), 200°F (930C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) QUICK RESPONSE Factory tested hydrostatically to 500 psi (34 Bars) HORIZONTAL LPCB/CE Maximum low temperature glass bulb rating is -67°F (-55°C) SIDEWALL HORIZONtAL Frame - bronze • Deflector - brass • Screw - brass SERIES GL-QRISW SIDEWALL Lodgement Wire - stainless steel • Bulb seat - copper SERIES GL-QRISW Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION I TEMPERATURES BULB COLOR CEILING TEMPERATURE ORDINARY 1 - ORANGE/RED [ - INTERMEDIATE *'4 F YELLOW/GREEN HIGH F- BLUE F ' I ' MAR 2018 GFS-100a (Formerly A-20) Quick RESPONSE A UTOMA TIC SPRINKLERS UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black.PoIyesterZ3 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9116". 2FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. LISTINGS/APPROVALS TEMPERATURE NYC -DOB STYLE SIN K FACTOR HAZARD' cULus FM LPCB2 CE MEA _____ 135°F 155F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) 101-92-E GL2815 2.8 LH X X X X X --- --- --- x GL4215 4.2 LH X X X X X X --- --- --- X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115* 8.0- (1/2" NPT) LH/OH X X X X X X --- --- --- X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X --- --- --- X GL4201 4.2 LH X X X X X X --- --- --- X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101* 8.0- (1/2" NPT) LH/OH X, X X X X X --- --- X 0L8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X GL2826 2.8 LH X X X X X X -- --- --- X GL4226 4.2 LH X X X X X X --- --- --- X H HORIZONTAL GL5626 5.6 LH/OH X X X X X X X --- --- X SIDEWALL GL5627D 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X --- CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- --- X --- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. DINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OR ORDINARY HAZARD LH: LIGHT HAZARD *1/2 NPT, FOR RETROFIT ONLY 2 LPCB REF. NO. 147c/05 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY I Globe agrees to repair or replace any of its own manufactured Quantity SIN . Style Orifice products found to be defective in material or workmanship for a Thread Size • Temperature • Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List PIN 312366 (L.a.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 4858 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com FIRE SPRINKLER CORPORATION MAR 2018 PRINTED U.S.A. GFS-100a (Formerly A-20)