Loading...
HomeMy WebLinkAbout2672 MADISON ST; ; FPR2017-0275; PermitLcity of Carlsbad Print Date: 12/13/2021 Job Address: 2672 MADISON ST, CARLSBAD, CA 92008-1721 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2017-0275 Status: Closed - Fina led Multifamily Fire Alarm Applied: 07/12/2017 Issued: 07/25/2017 0EV14037 Finaled Close Out: 12/09/2020 Inspector: Final Inspection: Project Title: BEACHWALK AT MADISON Description: BEACRWALK AT MADISON CONDO BLDG 1 - SPRINKLER MONITORING SYSTEM BLDG 1 & 2 ON SAME PLAN BLDG 1 FPR2017-0275 BLDG 2 FPR2017-0276 FPContractor: ADVANTAGE SECURITY AND MULTIMEDIA INC 9655 GRANITE RIDGE OR, # STE 200 SAN DIEGO, CA 92123-2658 (619) 997-7327 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov FPR20I 7-0275 2.h2- 2660-Madison ST SItI1M.IKG NYC Fire Dept. Certificate of @us i Approval LISTED Approved for DACT or Stand Alone IP S735 7165-0328:0204 Communications El POTTER The Symbol of Protection FPR20I 7-0276 PFC-6006 CONVENTIONAL FIRE PANEL! SPRINKLER MONITORING PANEL Features: O Programmable imitating Device Uircutis ClassAor Class B Waterfiow Initiating Circuit 2 Wire Smoke Detector Compatibility 2660 Madison ST 1.0 Amp Power Supply 1 Notification Circuit rated at 0.5 Amps Regulated Strobe Synchronization for Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock 0.5 Amp Auxiliary Power, Programmable as Constant or Resettable 2 x 16 LCD display with system LEDs for clear system status Keypad for system features P-Link for Remote Annunciator Connections Capacity to charge and house 1 8AH batteries Onboard Dual Line Digital Alarm Communicator Built-in Ethernet Connection with listed IP Communicator Ability to E-mail system status, reports and system configuration Service Reminder E-inails Electrical Specs AC Mains 1.O amp @ 120 VAC 60 Hz Battery 105 mA Standby 160 mAAlarm Dimensions 181/2"Hx141I4Wx43/4D General Description The PFC-6006 is a listed small conventional fire system ideally suited The panel has a dual telephone line digital alarm cotninunicatortransmitter to monitor a small fire system such as a fire sprinkler system. The first (DACT) built on-board. One or both telephone lines may be enabled five zones are selectable from a menu of options including two-wit-c updated panel configurationmay bcscnttothcpancltlmroughthctcicphonc smoke detection. The panel has a 1.0 amp power supply that powers lines. The panel has line in and line out to allow the panel to be installed the panel, charges the batteries and supplies 0.5 amps to a notification ahead of other telephone equipment on the premises. appliance circuit and 0.5 amps of auxiliary power. The auxiliary power is programmable as constant or resettable. The panel will supportup to four (4) ofthe RA-6075 remote annunciators th P-ir b::: '' ., ._..,i The control panel tis in a metal cabinet with a key lock and lexan key lock and provide full functionality of the system. window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be The panel is pre-programmed from the factory for monitoring a typical installed with minimal effort. The cabinet houses up to two I2VDC, 18 wet or dry fire sprinkler system. The programming may be changed using AH batteries, the Potter Fire Panel Programmer (available free from www.pottersignal - c.om ni a standard Ethcmct cable. The default orugrans a'. followa: The display is a thirty-two (32) characterLCD with system status LEDs. The system status is clearly displayed and the panel includes a history Input 1 - Waterfiow buffer for past events. The key pad allows navigation into the system Input 2 - Smoke Detection (two-wire) menu, limited programming and system control. The condition and Input 3 - Manual Pull Station events on the panel are clearly displayed to allow the user and installer Input 4 - Non-Latching Supervisory trs ,i.rtrrm,n tb iet,'ni stitils. lnnt S - \tilv Tnrnner Input 6 - Valve Tamper PotterElectric Signal Co., LLC St. Louis, MO • CustService: 866-240-1870 • Tech Support:866-956-1211 Canada 888-882-1833 www.pottersignal.com PRThJTED IN USA MKT #8830038 - REV A PAGE 1 OF 2 06/13 @POTTFR The Symbol of Protection PFC-6006 Sprinkler Monitoring Panel ED '0 ED lb ED b 100 erpcmSwcm o aLwmu tEARTH El RNtZORY OWEJIEED FORAY 0 ThSUtWBLE El) (I)) 1E] MEDED ALRRM SIGNAL ACTIVATION PRESS LEFT B RIGHT ARROW KEYS Al SAME TIM F TO TRIGGER ALARM SIGNAL ACtI RATION. A IAU11ON ONLY DETECTORSTHAT ARE SHOWN IN TOE COMPATIBILITY LIST AHETO BE USED. P015 DACE CONNECTION LAMP TEST. PRESS [ENTERS [05 PASSWORD, [6). PRESS THE [FSCI KEY WHEN DONE (DPOTTER CONVENTIONAL FIRE PANEL! The Symbol of Protection SPRINKLER MONITORING PANEL General Description (Cont.) hi the standard program, Input 1 is defaulted as a Water flow zone. jupta t is site oil IV class tt,Ciass B Zone. [EtC pallet %S III auLOucau- caily determine Class A or B based on wiring and the presence of the end of line resistor. All of the inputs may be programmed for General Alarm, Waterflo Two-Wire Smoke Detector, Heat Detector, Manual Pull Station, Non-latching Supervisory, Latching Supervisory, or Valve Tam. ier. The NAC is listed for strobe synchronization and the panel is listed tviui roEtclrtuvInL..sJ, ucuEcx. .ysLctlS Densul. ESIW L_UUpei Vt ImclocK signals. Please refer to the Potter Notification Compatibility Docu- ment for the maximum number of strobe devices that may be con- nected. The maximum output is 0.5 amps. The Fthernet C isecttictn ma'.' he connected to a buildina neti','nIl: with internet to provide e-mail notifications of system status, reports, or system configuration. In addition, the Ethernet connection is listed for IP reporting to a monitoring station. CAUTION: De-Energize Unit Prior to Servicing 1 2OVAC 60Hz Connect to separate unswitched AC circuit Use 14 AWG or heavier gauge wire with 600V insulation WARNING: RADIO FREQUENCY FROM NSE TRANSMITTING DEVICES MAY IMPAIR INTENDED OPERATION OF THE CONTROL UNIT. MAINTAIN A MINIMUM OF 30CM BETWEEN TRANSMITTING DEVICES AND CONTROL UNIT. AVER11SSEMENT: LES RADIOFREQUENCES WISES PAR LES DISPOSI11FS DE TRANSMISSION PEUVENT NUIRE AU FONC110NNEMENT PREVU DU POSTE DE CONTROLE. MAINTENIR LINE DISTANCE D'AU MOINS 30 CIA ENTIRE LES DISPOSITIFS DE TRANSMISSION ET LE POSTE DE CON TROLE. Primary AC 120 VAC. 60Hz, .75 AMP Min Low AC Detect 98VAC Battery (barging 27.3VDC€l.5A FUSE Low Battery Detect @2IS4VDC All Circuit impedance Values Short Circuit OOhms Open Circuit >10K Earth Fault to anyterminal: ROlims Main Fuse Specification L1 E.C.L. LO.L E.O.L £O.L E.O.L. EO.L E.O.L. 1.6A 250VAC Programming 6 Ccoeentic'nat Inputs, rutty programmable Batt, Fuse Spedlication BSIMIWNT Connection A support wire smoke detector 2,5A-250VAC SPIlt SIGNAL S'O'EU corerttoor,rr Requirements System must be fully tested after insrallatieru Intended for induce use in dry locations only. OF FCC Ball + Separation ulpower limited wiring lionS 000fXlWOt Iirst0etJ wiring must beat This device has been verified to comply with FCC Rules Part 15, Batter - least 114. Install in accordance with installation manual PoTNumber 5403550- 03ss A Operation is subject to lire lolluwing condilirurs and Operating instructions- Part #5406282 rhisdeoicemaynotcaureractio interFerence. This device must accept any interference received inducting any See Smoke Detector Compatibility IderrOter A' that may cause undesired operation. Acknowledgements NFPA Conrnrerdal Protected Remises Control Unit for Iii Installations Gr,'ntex°, Cooper Wlreetock°, and System Sensor °syndrrosizalicsi 13.70. arid NFFA7S. protocols used with permission. Cooper Wheelock Patent Nor. 5,400,009. Alarm activation requiring activation 01 two or more automatic detection devices shall not utilize any time delay- Pone Electric Signal Company LLC Service Use for RI Installations, PFC-6006 - Local US: POTALOSBSMP -Remote Staliun Complies with 47 (FR Part 68. - Proprietary Made in USA - Central Station See board for Serial 4. Battery connection (non-power limited). SERVICEUSE AND COMMERCIAL PROTECTED PREMISES UNIT FOR ULC INSTALLATIONS, Use two (2) 12V batteries connected in series. WIRING METHODS SHALL BE IN ACCORDANCE WITH CSAC22,1, SAFETY STANDARD FOR ELECT RICALINSTALLATIONSICONADIAN ELECTRICAL COD E. PART l, SECT IONS 32. P/N 5.406280 (10/31/204) LOCAL SERVICE TYPES INON-COTtEDE AM, SS, WF. Potter hicciric signal Co., LLC • St. Louis, MO • Cusi Service: 906-240-1810 • thch Suppor1:066-956- 2 i - Canada 88.5-582- I83 . wwwpollcrsignal.com PRINTED IN USA MKT #8830038- REV A PAGE 2 OF 2 06/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0204 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Model PFC-6006 fire alarm control panel. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listees Installation Instruction Manual for details. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally II IIULII iy 1:111U H IUI%.dLII y r'.eeI LU litee II IL1Idt.IUI I II ILI ULl L'ull With tUth for details. 07-25-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct r.rrr1 r r In rf tr::r .rr!r.r f!r - --- .....................................- .....-. -------------------•••_ ............................. Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (DPOTTER PHOTOELECTRIC The Symbol of Protection SMOKE DETECTOR - -'S- * 'I UL, ULC, and CSFM Listed, FM Approved Light Source: GaA1As Infrared Emitting Diode Rated Voltage: 17.7 - 33.0 VDC Working Voltage: 15.0 - 33.0 VDC Maximum Voltage: 42 VDC Supervisory Current: 45 iA Max. at 24 VDC Surge Current: 160 pA Max. at 24 VDC Alarm Current: 150 mA Max. at 24 VDC Ambient Temperature: 32°F to 120°F (0°C to 49°C) Sensitivity Test Feature: Automatic Sensitivity window verification test. Mounting: Refer to Potter SB Series Smoke Detector Base series, bulletin no. 8840008. Stock number: 1430011 Standard Features Operation Low profile, 1.8" high (with base) The PS-24 photoelectric smoke detector utilizes two bi-colored LED's 2 or 4 wire base compatibility, relay bases available for indication of status In a normal standby condition the LED's flash Highly stable operatioii. RFi'Fransient protection LED'sthe red Low standby current, 45 1iA at 24 VDC every 3 seconds. When the detector senses smoke and goes into alarm Two built-in power/sensitivity supervision/alarm LED's the status LED's will latch on red. Non-directional smoke chamber Vandal reEistsnt security locking feature Built-in magnetic go/no go detector test feature Removable smoke labyrinth for cleaning or replacement Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance. Compatible with IS-24 ionization detectors Backwards compatible with Potter PS and IS detectors. Compatible with Potter releasing controls The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, tile leceivilig eleilleIIL icCCi i1UUIL tioiti he pu1si11LEL.F ligillsoutce. in the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level, and when two consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LED's light continuously during the alarm period. Application ii. .. . I 11 S ,3L9 11 1JI t1su IH jill UIVUS WII'1¼j I iiu1uCICI4I1 )1UtPci.JUt¼1U1b are required. The wide range smoke chamber makes thePS-24 well suited for fires ranging from smoldering to flaming fires. SB Series Stylebases maybe used with the PS-24. Current interchangeable/ compatible devices are the IS-24 ionization detector. Potter Electric Signal Co.. LLC • SL Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MKT. #8840007 - REV G PAGE 1 OF 2 5/04 (DPOTTER PHOTOELECTRIC The Symbol of Protection SMOKE DETECTOR Engineering Specifications The contractor shall famish and install where indicated on the plans, Potter Model PS-24 photoelectric smoke detectors. The combination detector head and twist-lock base shüli be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Potter, PS-24H, combination photoelectric/heat detector and IS-24 ionization type smoke detector. The base shall be appropriate twist-lock base SB Series. In the event of partial or complete retrofit, the PS-24 may be used in conjunction with, UI as U ICiUII1flt IUI. 1UIIUI UVILUIS -frt 1LA$11 WIU UI 10L'+J the SB base applications. The smoke detector shall have two flashing status LED's for visual supervision. When the detector is in standby condition the LED's will flash green. When the detector is outside the UL listed sensitivity window the LED's will flash red. When the detector is actuated, the flashing LEDs wiii latch on red. the detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector without the need utgemimaumig sifioic. Tii sIisiuviLy U mv uivctUi bliall b automatically and continuously to verify that it is operating within the listed sensitivity range. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where II1UIUuttU. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Specifications subject to change without notice. PS-24 Sensitivity Test Feature The PS24 Photoelectric Smoke Deteclor has a built-in automatic sensitivity test feature. I. In normal condition, boils LED's flash green. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red. in the alarm state both LED's are red continuously. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be cleaned or returned to the factory PRINTED IN USA MKT. #8840007 - REV G PAGE 2 OF 2 8104 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models BPS-2, PS-24H and PS-24 photoelectric type smoke detectors. Unit with suffix -H employs a supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12 VDC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm \.UltLUJI UIIIL VYUII UCU III LIVIIJUMAIU11 YVIUI IIbLVVZI IIWU .rwl LtUy IMU. 7300-0328:153). Models with supplemental heat sensor are not approved for use in lieu of the required heat detectors. XLF: 7272-0410:0107 9-11-2001 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Pf,r ir ri!r.r hr - ..-. --------------------..--.- ............................ Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0153 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BiIIWpottersignal.com DESIGN: Models SB4-43R, SB-81R, ASB-6, SB-150, SB-93, SB-46 and SB-43 detector bases (2 and 4-wire). Unit is intended for use with a separately listed compatible detector head. Refer to listees data sheet for detailed product description and operational considerations. Models may or may not come with suffix -W. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as bases for use With istee's separateiy llsted compaticie smoke arid heat detectors. Refer to heat or smoke detector listings for compatibility. Models SB4-43R and SB-81 R are also suitable for releasing device service. XLF: 7300-0410:0132 9-11-2001 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct -. '' rtirr rrrt i!thr rirri rit if r;r rfkr u._______JJ ............ .......- -. -..- Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DIE-CAST METAL (E)POTTER PULL STATION SEWES The Symbol of Protection MANUAL PULL STATIONS 1!aunn LJ wall Description The Potter Pull Station Series offers a complete line of die-cast pull stations for a variety of applications focusing mainly on fire alarm systems. The pull stations are available in single or dual action A!! !! - ..---. -.. -- a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The standard models have a hex key reset, however a key reset is also available. The models are available with shallow and deep surface U&tUtIL uca..t¼ U.tAt.., UIIU CCC U iC.aLitUl tUt,I Ll Operation The Potter single action series of pull stations operate by pulling the white operating handle straight down and the handle will lock into place. The dual action stations require the lifting of the front cover and then pulling the white operating handle straight down. The stations are reset by opening the front and placing the handle in the normal position. Ordering Information UL and cUL Listed, FM Approved, CSFM Listed, MEA Approved, ADA Compliant Single or Dual Action Terminal connectors 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox Surface back-boxes available High-gloss red enamel finish Glass break-rod Made in the U.S.A. Engineering Specifications The contractor shall furnish and install the Potter series of pull stations as indicated. The pull station shall be die cast construction with a "T" type pull handle that is ADA compliant. Single action pull stations shall ho. a P32-IT. Dual action pull stations shall ho tho Pottcr P32-IT-LP. Any manual pull station installed in an outdoor or wet location shall be a RMS-1T-WP weather proof unit. Time contact shall be a single pole, single throw switch rated at 1 amp 30V DC/125V AC. The device shall have a terminal block for ease of wiring. Once activated, the pull station shall be reset by opening the front cover. flnening nf tb ,nvnr in n nnrn11l s11Ie shi11 inilinle nn i1irrn Specifications Switch Rating: 1 Amp @30 VDC 10 Amps @ 125 VAC Pull Station Dimensions: 4-3/4" H x 3-1/4" W x 7/8" D Color: Red with raised white letters, white pull bar with raised red letters For special application manual stations see bulletin #8910014. For explosion proof manual stations see bulletin #8880014. Type Model Number Stock Number Contact Type Single Action P32-IT 1000447 SPST RMS-2T 1000477 DPST RMS-6T 1000478 DPDT RMS-IT-KT. 1000451 1 SPST RMS-1T-KO 1000450 SPST, key operated, no pull Weather Proof RMS- lT-WP 1000401 SPST 1000403 Dual Action P32-1T-LP 1000476 Weather Proof Dual Action RMS-1T-WP-LP Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 J Replacement glass rods (10 per pkg) Potter Electric Signal Co., LLC • St. Louis, M0 CustService: 866-240-1870 Tech Support:866-956-121 1• Canada 888-8g2-1833 www.pottersignal.com PRINTED IN USA MKT. #8900097 - REV L PAGE 1 OF 1 9/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0328:0156 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Coi609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BilIW©pottersignal.com DESIGN: Models P32-1T (alien or key, no push bar) and P32-1T-LP (key lock or alien key) noncoded manual pull stations. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 10 Amp. @ 120 VAC, 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control u uiL. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1039:0101 *Rev 8-3-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct rr.r rr rsrr r n fr r'' fithr r,i!r.r fh.r .......... -..--- .......-.- ............................ Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division