HomeMy WebLinkAbout951 PALOMAR AIRPORT RD; ; FPC2020-0105; Permit(Jity of PERMIT REPORT Carlsbad Print Date: 10/20/2020 Permit No: FPC2020-0105 Job Address: 951 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-1110 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2110403600 Track #: Applied: 06/22/2020 Valuation: $716,254.00 Lot #: Issued: 07/28/2020 Occupancy Group: Project #: Finaled Close Out: 10/20/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: COSTCO -NEW SPRINLER IN COOLER, DELI & MEAT PREP AREA (142 HEADS) Applicant: FPContractor: LINDLEY FIRE PROTECTION LINDLEY FIRE PROTECTION CO INC-DO NOT JAVIER MEJIA USE 2220 E VIA BURTON 1109 N ARMANDO ST ANAHEIM, CA 92806-1221 ANAHEIM, CA 92806-2609 (714) 984-4150 (714) 535-5761 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $654.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ffczc2-c) -c3)5 LINDLEY FIRE PROTECTION CO. 1109 N. ARMANIO STREET ANAHEIM, CA 714-535-5761 LIC. # C161C34 NO. 1037930 HYDRAULIC CALCULATIONS FOR COSTCO #462 CARLSBAD 951 PALOMAR AIRPORT ROAD CARLSBAD, CA 92011 a REMOTE #1- POS FREEZER/COOLER DATE: 05-31-2020 -DESIGN DATA- SYSTEM DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (INCLUDING HOSE) FLOW AND PRESSURE & BASE OF RISER SPRINKLER ORIFICE SIZE: .43 GPM/SQ. FT. 2,000 S.F. 90 SQ. FT. 25 SPRINKLERS 1148.1 GPM 1648.1 GPM 1148.1 GPM @55.6 PSI 3/4" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 102 63.0 40.0 4060.0 58.7 1648.1 55.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1648.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 500.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 1148.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) DP01 22.2 K=11.20 17.7 47.1 DP02 22.2 K=11.20 17.7 47.1 DP03 22.2 K=11.20 17.8 47.2 DP04 22.2 K=11.20 15.9 44.7 DP05 22.2 K=11.20 12.0 38.8 DP06 22.2 K=11.20 12.0 38.8 DP07 22.2 K=11.20 17.2 46.5 DPOB 22.2 K=11.20 15.8 44.5 DP09 22.2 K=11.20 15.6 44.2 DP10 22.2 K=11.20 18.6 48.3 DP11 22.2 K=11.20 18.6 48.3 DP12 22.2 K=11.20 17.9 47.4 DP13 22.2 K=11.20 17.7 47.2 DP14 22.2 K=11.20 18.6 48.3 DP15 22.2 K=11.20 18.6 48.3 DP16 22.5 K=11.20 18.5 48.2 DP17 22.5 K=11.20 18.5 48.2 DP18 22.5 K=11.20 17.9 47.3 DP19 22.5 K=11.20 17.7 47.2 DP20 22.5 K=11.20 15.8 44.5 DP21 22.5 K=11.20 15.8 44.5 DP22 22.5 K=11.20 17.2 46.4 DP23 22.5 K=11.20 17.3 46.6 DP24 22.5 K11.20 15.6 44.2 DP25 22.5 K=11.20 15.8 44.5 AOl 30.5 - - - - 16.0 - - - A02 30.5 - - - - 16.0 - - - A03 30.5 - - - - 16.1 - - - A04 30.5 - - - - 14.0 - - - A05 30.5 - - - - 9.7 - - - AOG 30.5 - - - - 18.2 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/19/2018 C:\PROGR11'4 FILES\HRS SYSTEMS\I-1ASS88\#0061.SDF JOB TITLE: 0462 COSTCO - CARLSBAD, CA - REMOTE #1/POS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A07 30.5 - - - - 15.5 - - - A08 30.5 - - - - 13.9 - - - A09 30.5 - - - - 13.7 - - - A10 30.5 - - - - 17.0 - - - All 30.5 - - - - 17.0 - - - Al2 30.5 - - - - 16.2 - - A13 30.5 - - - - 16.1 - - - A14 30.5 - - - - 17.0 - - - A15 30.5 - - - - 17.0 - - - A16 30.5 - - - - 17.0 - - - A17 30.5 - - - - 17.0 - - - A18 30.5 - - - - 16.3 - - - A19 30.5 - - - - 16.1 - - - A20 30.5 - - - - 14.0 - - - A21 30.5 - - - - 14.0 - - - A22 30.5 - - - - 15.5 - - - A23 30.5 - - - - 15.6 - - - A24 30.5 - - - - 13.8 - - - A25 30.5 - - - - 14.0 B01 30.0 - - - - 18.3 - - - 802 30.0 - - - - 18.3 - - - B03 30.0 - - - - 18.4 - - - B04 30.0 - - - - 16.3 - - - B05 30.0 - - - - 16.2 - - - B06 30.0 - - - - 18.4 - - - 807 30.0 - - - - 18.4 - - - BOB 30.0 - - - - 16.1 - - - B09 30.0 - - - - 16.1 - - - B10 30.0 - - - - 18.9 - - - Bil 30.0 - - - - 19.0 - - - 812 30.0 - - - - 19.0 - - - 813 30.0 - - - - 19.0 - - 814 30.0 - - - - 18.9 - - - B15 30.0 - - - - 19.0 - - - B16 30.0 - - - - 18.9 - - - 817 30.0 - - - - 19.0 - - - 818 30.0 - - - - 19.0 - - - 819 30.0 - - - - 19.0 - - - 820 30.0 - - - - 16.3 - - - B21 30.0 - - - - 16.5 - - - B22 30.0 - - - - 18.4 - - - B23 30.0 - - - - 18.6 - - - B24 30.0 - - - - 16.2 - - - 1325 30.0 - - - - 16.4 - - - 1 28.0 - - - - 26.8 - - - 1A 30.0 - - - - 25.6 - - - 2 28.0 - - - - 19.9 - - - 2A 30.0 - - - - 19.3 - - - 3 26.0 - - - - 26.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/19/2018 C:\PROGR1.M FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 3A 30.0 - - - - 25.3 - - - 4 28.0 - - - - 19.9 - - - 4A 30.0 - - - - 19.3 - - - 5 28.0 - - - - 26.3 - - - 5A 30.0 - - - - 24.9 - - - 6 28.0 - - - - 19.9 - - - 6A 30.0 - - - - 18.9 - - - 7 28.0 - - - - 26.1 - - - 7A 30.0 - - - - 24.6 - - - 8 28.0 - - - - 19.9 - - - 8A 30.0 - - - - 18:5 - - - 9 28.0 - - - - 26.0 - - - 9A 30.0 - - - - 24.6 - - - 10 28.0 - - - - 19.9 - - - bA 30.0 - - - - 18.9 - - - 11 28.0 - - - - 25.9 - - - hA 30.0 - - - - 24.7 - - - 12 28.0 - - - - 19.9 - - - 12A 30.0 - - - - 19.3 - - - 13 28.0 - - - - 25.8 - - - 13A 30.0 - - - - 24.2 - - - 14 28.0 - - - - 19.9 - - - 14A 30.0 - - - - 18.8 - - - 15 28.0 - - - - 25.7 - - - 15A 30.0 - - - - 24.4 - - - 16 28.0 - - - - 19.9 - - - 16A 30.0 - - - - 19.0 - - - 17 28.0 - - - - 25.7 - - - 17A 30.0 - - - - 24.4 - - - 18 28.0 - - - - 19.9 - - - 18A 30.0 - - - - 19.0 - - - 19 28.0 - - - - 25.6 - - - 19A 30.0 - - - - 24.5 - - - 20 28.0 - - - - 19.9 - - - 20A 30.0 - - - - 19.3 - - - 21 28.0 - - - - 25.6 - - - 21A 30.0 - - - - 24.4 - - - 22 28.0 - - - - 19.9 - - - 22A 30.0 - - - - 19.0 23 28.0 - - - - 25.6 - - - 23A 30.0 - - - - 24.4 - - - 24 28.0 - - - - 19.9 - - - 24A 30.0 - - - - 19.0 - - - 25 28.0 - - - - 25.6 - - - 25A 30.0 - - - - 24.4 - - - 26 28.0 - - - - 19.9 - - - 26A 30.0 - - - - 19.0 - - - 95 28.0 - - - - 30.9 - - - 96 3.0 HOSE STREAM 42.9 100.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/19/2018 C:\PROGRAI4 FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: 0462 COSTCO - CARLSBAD, CA - REMOTE #1/POS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 97 1.0 - - - - 44.3 98 -3.0 - - - - 46.6 - - - 99 -3.0 - - - - 51.6 100 -3.0 HOSE STREAM 53.2 400.0 101 -3.0 - - - - 54.3 102 -3.0 SOURCE 55.6 1648.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\4t006_1.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -47.1 1.380 FL 8.25 PF 1.9 DP01 22.2 11.2 17.7 47.1 10.1 120 FTG E PE -3.6 AOl 30.5 0.0 16.0 0.0 0.167 TL 11.25 PV Pipe: 2 -47.1 1.380 PL 8.25 PP 1.9 DP02 22.2 11.2 17.7 47.1 10.1 120 FTG E PE -3.6 A02 30.5 0.0 16.0 0.0 0.167 TL 11.25 PV Pipe: 3 -47.2 1.380 PL 8.25 PF 1.9 DP03 22.2 11.2 17.8 47.2 10.1 120 FTG E PE -3.6 A03 30.5 0.0 16.1 0.0 0.167 TL 11.25 PV Pipe: 4 -44.7 1.380 FL 8.25 PF 1.7 DP04 22.2 11.2 15.9 44.7 9.6 120 FTG E PE -3.6 A04 30.5 0.0 14.0 0.0 0.151 TL 11.25 PV Pipe: 5 -38.8 1.380 FL 8.25 PP 1.3 DP05 22.2 11.2 12.0 38.8 8.3 120 FTC E FE -3.6 A05 30.5 0.0 9.7 0.0 0.116 TL 11.25 PV Pipe: 6 -38.8 1.380 PL 8.25 PP 1.3 DP06 22.2 11.2 12.0 38.8 8.3 120 FTG E PE -3.6 A05 30.5 0.0 9.7 0.0 0.116 TL 11.25 PV Pipe: 7 -46.5 1.380 FL 8.25 PF 1.8 DPO7 22.2 11.2 17.2 46.5 10.0 120 FTG E PE -3.6 A07 30.5 0.0 15.5 0.0 0.163 TL 11.25 PV Pipe: 8 -44.5 1.380 FL 8.25 PF 1.7 DP08 22.2 11.2 15.8 44.5 9.5 120 FTC E PE -3.6 A08 30.5 0.0 13.9 0.0 0.150 TL 11.25 PV Pipe: 9 -44.2 1.380 PL 8.25 PF 1.7 DP09 22.2 11.2 15.6 44.2 9.5 120 FTC E PE -3.6 09 30.5 0.0 13.7 0.0 0.148 TL 11.25 PV Pipe: 10 -48.3 1.380 FL 8.25 PF 2.0 DPlO 22.2 11.2 18.6 48.3 10.4 120 FTC E FE -3.6 A10 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 11 -48.3 1.380 FL 8.25 PF 2.0 DP11 22.2 11.2 18.6 48.3 10.4 120 FTC E FE -3.6 All 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 12 -47.4 1.380 FL 8.25 PF 1.9 DP12 22.2 11.2 17.9 47.4 10.2 120 FTG E FE -3.6 Al2 30.5 0.0 16.2 0.0 0.169 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -47.2 1.380 PL 8.25 PF 1.9 DP13 22.2 11.2 17.7 47.2 10.1 120 FTG E PH -3.6 A13 30.5 0.0 16.1 0.0 0.167 TL 11.25 PV Pipe: 14 -48.3 1.380 FL 8.25 PF 2.0 DP14 22.2 11.2 18.6 48.3 10.4 120 FTG H PE -3.6 A14 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 15 -48.3 1.380 PL 8.25 PF 2.0 DP15 22.2 11.2 18.6 48.3 10.4 120 FTG E PE -3.6 A15 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 16 -48.2 1.380 FL 8.25 PF 2.0 DP16 22.5 11.2 18.5 48.2 10.3 120 FTG H FE -3.5 A16 30.5 0.0 17.0 0.0 0.174 TL 11.25 PV Pipe: 17 -48.2 1.380 PL 8.25 PF 2.0 DF17 22.5 11.2 18.5 48.2 10.3 120 FTG E FE -3.5 A17 30.5 0.0 17.0 0.0 0.174 TL 11.25 PV Pipe: 18 -47.3 1.380 PL 8.25 PF 1.9 DP18 22.5 11.2 17.9 47.3 10.2 120 FTG H FE -3.5 A18 30.5 0.0 16.3 0.0 0.168 TL 11.25 PV Pipe: 19 -47.2 1.380 PL 8.25 PF 1.9 DP19 22.5 11.2 17.7 47.2 10.1 120 FTG E FE -3.5 A19 30.5 0.0 16.1 0.0 0.167 TL 11.25 PV Pipe: 20 -44.5 1.380 FL 8.25 PF 1.7 DP20 22.5 11.2 15.8 44.5 9.6 120 FTG E FE -3.5 A20 30.5 0.0 14.0 0.0 0.150 TL 11.25 PV Pipe: 21 -44.5 1.380 PL 8.25 PF 1.7 DP21 22.5 11.2 15.8 44.5 9.5 120 FTG E FE -3.5 A21 30.5 0.0 14.0 0.0 0.150 TL 11.25 PV Pipe: 22 -46.4 1.380 FL 8.25 PF 1.8 DP22 22.5 11.2 17.2 46.4 10.0 120 FTG H FE -3.5 A22 30.5 0.0 15.5 0.0 0.162 TL 11.25 Pv Pipe: 23 -46.6 1.380 FL 8.25 PF 1.8 DP23 22.5 11.2 17.3 46.6 10.0 120 FTG E PE -3.5 A23 30.5 0.0 15.6 0.0 0.163 TL 11.25 PV Pipe: 24 -44.2 1.380 FL 8.25 PF 1.7 DP24 22.5 11.2 15.6 44.2 9.5 120 FTG E PE -3.5 A24 30.5 0.0 13.8 0.0 0.149 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/19/2018 C:\PROGP.AM FILES\HRS SYSTEMS\HASS88\#006_1.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 -44.5 1.380 FL 8.25 PF 1.7 DP25 22.5 11.2 15.8 44.5 9.6 120 FTG E FE -3.5 A25 30.5 0.0 14.0 0.0 0.150 TL 11.25 PV Pipe: 26 -47.1 1.380 PL 3.50 PF 2.1 AOl 30.5 0.0 16.0 0.0 10.1 120 FTG ET FE 0.2 B01 30.0 0.0 18.3 0.0 0.167 TL 12.50 PV Pipe: 27 -47.1 1.380 FL 3.50 PF 2.1 A02 30.5 0.0 16.0 0.0 10.1 120 FTC ET PE 0.2 B02 30.0 0.0 18.3 0.0 0.167 TL 12.50 PV Pipe: 28 -47.2 1.380 FL 3.50 PF 2.1 A03 30.5 0.0 16.1 0.0 10.1 120 FTG ET PE 0.2 B03 30.0 0.0 18.4 0.0 0.167 TL 12.50 PV Pipe: 29 -44.7 1.380 FL 4.50 PF 2.0 A04 30.5 0.0 14.0 0.0 9.6 120 FTC ET FE 0.2 B04 30.0 0.0 16.3 0.0 0.151 TL 13.50 PV Pipe: 30 -77.5 1.380 FL 6.00 PF 6.3 A05 30.5 0.0 9.7 0.0 16.6 120 FTG ET FE 0.2 B05 30.0 0.0 16.2 0.0 0.420 TL 15.00 PV Pipe: 31 0.0 1.380 FL 6.50 PF 0.0 A06 30.5 0.0 18.2 0.0 0.0 120 FTC ET PE 0.2 B06 30.0 0.0 18.4 0.0 0.000 TL 15.50 PV Pipe: 32 -46.5 1.380 PL 7.75 PF 2.7 A07 30.5 0.0 15.5 0.0 10.0 120 FTG ET FE 0.2 B07 30.0 0.0 18.4 0.0 0.163 TL 16.75 PV Pipe: 33 -44.5 1.380 PL 4.50 PF 2.0 A08 30.5 0.0 13.9 0.0 9.5 120 FTG ET FE 0.2 BOS 30.0 0.0 16.1 0.0 0.150 TL 13.50 PV Pipe: 34 -44.2 1.380 PL 6.25 FE' 2.3 A09 30.5 0.0 13.7 0.0 9.5 120 FTG ET FE 0.2 B09 30.0 0.0 16.1 0.0 0.148 TL 15.25 PV Pipe: 35 -48.3 1.380 FL 1.00 PF 1.7 AiD 30.5 0.0 17.0 0.0 10.4 120 FTG ET FE 0.2 B10 30.0 0.0 18.9 0.0 0.175 TL 10.00 PV Pipe: 36 -48.3 1.380 FL 1.00 PF 1.8 All 30.5 00 17.0 0.0 10.4 120 FTC ET FE 0.2 Bil 30.0 0.0 19.0 0.0 0.175 TL 10.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/19/2018 C:\PROGRA}4 FILES\HRS SYSTEMS\RASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUN. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 37 -47.4 1.380 PL 6.00 PF 2.5 Al2 30.5 0.0 16.2 0.0 10.2 120 FTG ET PE 0.2 B12 30.0 0.0 19.0 0.0 0.169 TL 15.00 PV Pipe: 38 -47.2 1.380 PL 7.25 PF 2.7 A13 30.5 0.0 16.1 0.0 10.1 120 FTC ET PE 0.2 B13 30.0 0.0 19.0 0.0 0.167 TL 16.25 PV Pipe: 39 -48.3 1.380 PL 1.00 PF 1.7 A14 30.5 0.0 17.0 0.0 10.4 120 FTC ET PE 0.2 814 30.0 0.0 18.9 0.0 0.175 TL 10.00 PV Pipe: 40 -48.3 1.380 PL 1.00 PF 1.7 A15 30.5 0.0 17.0 0.0 10.4 120 FTG ET PE 0.2 B15 30.0 0.0 19.0 0.0 0.175 TL 10.00 PV Pipe: 41 -48.2 1.380 PL 1.00 PF 1.7 A16 30.5 0.0 17.0 0.0 10.3 120 FTG ET PE 0.2 816 30.0 0.0 18.9 0.0 0.174 TL 10.00 PV Pipe: 42 -48.2 1.380 PL 1.00 PF 1.7 A17 30.5 0.0 17.0 0.0 10.3 120 FTG ET PE 0.2 B17 30.0 0.0 19.0 0.0 0.174 TL 10.00 PV Pipe: 43 -47.3 1.380 PL 5.50 PF 2.4 A18 30.5 0.0 16.3 0.0 10.2 120 FTG ET PE 0.2 818 30.0 0.0 19.0 0.0 0.168 TL 14.50 PV Pipe: 44 -47.2 1.380 PL 6.75 PF 2.6 A19 30.5 0.0 16.1 0.0 10.1 120 FTG ET PE 0.2 819 30.0 0.0 19.0 0.0 0.167 TL 15.75 PV Pipe: 45 -44.5 1.380 PL 4.50 PF 2.0 A20 30.5 0.0 14.0 0.0 9.6 120 FTG ET PE 0.2 B20 30.0 0.0 16.3 0.0 0.150 TL 13.50 PV Pipe: 46 -44.5 1.380 PL 6.50 PF 2.3 A21 30.5 0.0 14.0 0.0 9.5 120 FTG ET FE 0.2 B21 30.0 0.0 16.5 0.0 0.150 TL 15.50 PV Pipe: 47 -46.4 1.380 PL 7.50 PF 2.7 A22 30.5 0.0 15.5 0.0 10.0 120 FTG ET PE 0.2 822 30.0 0.0 18.4 0.0 0.162 TL 16.50 PV Pipe: 48 -46.6 1.380 FL 7.50 PF 2.7 A23 30.5 0.0 15.6 0.0 10.0 120 FTG ET FE 0.2 B23 30.0 0.0 18.6 0.0 0.163 TL 16.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006_1.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 49 -44.2 1.380 FL 5.50 PF 2.2 A24 30.5 0.0 13.8 0.0 9.5 120 FTG ET FE 0.2 B24 30.0 0.0 16.2 0.0 0.149 TL 14.50 PV Pipe: 50 -44.5 1.380 FL 5.50 PF 2.2 A25 30.5 0.0 14.0 0.0 9.6 120 FTC ET PE 0.2 B25 30.0 0.0 16.4 0.0 0.150 TL 14.50 PV Pipe: 51 77.8 2.635 FL 2.00 PF 0.3 1 28.0 0.0 26.8 0.0 4.6 120 FTG T PE -0.9 1A 30.0 0.0 25.6 0.0 0.018 TL 18.47 PV Pipe: 52 -77.8 2.635 FL 2.00 PF 0.3 2 28.0 0.0 19.9 0.0 4.6 120 FTG T FE -0.9 2A 30.0 0.0 19.3 0.0 0.018 TL 18.47 PV Pipe: 53 76.2 2.635 FL 2.00 PF 0.3 3 28.0 0.0 26.5 0.0 4.5 120 FTG T FE -0.9 3A 30.0 0.0 25.3 0.0 0.017 TL 18.47 PV Pipe: 54 -76.2 2.635 FL 2.00 PP 0.3 4 28.0 0.0 19.9 0.0 4.5 120 FTG T FE -0.9 4A 30.0 0.0 19.3 0.0 0.017 TL 18.47 PV Pipe: 55 96.4 2.635 FL 2.00 PF 0.5 5 28.0 0.0 26.3 0.0 5.7 120 FTG T FE -0.9 5A 30.0 0.0 24.9 0.0 0.027 TL 18.47 PV Pipe: 56 45.0 2.635 FL 2.00 PF 0.1 6 28.0 0.0 19.9 0.0 2.6 120 FTG T PE -0.9 6A 30.0 0.0 18.9 0.0 0.007 TL 18.47 PV Pipe: 57 115.8 2.635 PL 2.00 PF 0.7 7 28.0 0.0 26.1 0.0 6.8 120 FTG T FE -0.9 7A 30.0 0.0 24.6 0.0 0.038 TL 18.47 PV Pipe: 58 95.4 2.635 FL 2.00 PF 0.5 8 28.0 0.0 19.9 0.0 5.6 120 FTG T FE -0.9 8A 30.0 0.0 18.5 0.0 0.026 TL 18.47 PV Pipe: 59 99.3 2.635 PL 2.00 PF 0.5 9 28.0 0.0 26.0 0.0 5.8 120 FTG T FE -0.9 9A 30.0 0.0 24.6 0.0 0.028 TL 18.47 PV Pipe: 60 40.1 2.635 PL 2.00 PF 0.1 10 28.0 0.0 19.9 0.0 2.4 120 FTG T PE -0.9 bA 30.0 0.0 18.9 0.0 0.005 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 61 72.1 2.635 PL 2.00 PF 0.3 11 28.0 0.0 25.9 0.0 4.2 120 FTG T FE -0.9 hA 30.0 0.0 24.7 0.0 0.016 TL 18.47 PV Pipe: 62 -72.1 2.635 PL 2.00 PF 0.3 12 28.0 0.0 19.9 0.0 4.2 120 FTG T PE -0.9 12A 30.0 0.0 19.3 0.0 0.016 TL 18.47 PV Pipe: 63 114.1 2.635 PL 2.00 PP 0.7 13 28.0 0.0 25.8 0.0 6.7 120 FTG T FE -0.9 13A 30.0 0.0 24.2 0.0 0.037 TL 18.47 PV Pipe: 64 63.3 2.635 PL 2.00 PP 0.2 14 28.0 0.0 19.9 0.0 3.7 120 FTG T FE -0.9 14A 30.0 0.0 18.8 0.0 0.012 TL 18.47 PV Pipe: 65 85.7 2.635 PL 2.00 PF 0.4 15 28.0 0.0 25.7 0.0 5.0 120 FTG T FE -0.9 iSA 30.0 0.0 24.4 0.0 0.022 TL 18.47 PV Pipe: 66 10.9 2.635 FL 2.00 PF 0.0 16 28.0 0.0 19.9 0.0 0.6 120 FTG T FE -0.9 16A 30.0 0.0 19.0 0.0 0.000 TL 18.47 PV Pipe: 67 85.2 2.635 FL 2.00 PF 0.4 17 28.0 0.0 25.7 0.0 5.0 120 FTG T FE -0.9 17A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 68 9.3 2.635 FL 2.00 FE 0.0 18 28.0 0.0 19.9 0.0 0.5 120 FTG T FE -0.9 18A 30.0 0.0 19.0 0.0 0.000 TL 18.47 PV Pipe: 69 70.7 2.635 PL 2.00 FE 0.3 19 28.0 0.0 25.6 0.0 4.2 120 FTG T FE -0.9 19A 30.0 0.0 24.5 0.0 0.015 TL 18.47 PV Pipe: 70 -70.7 2.635 FL 2.00 PP 0.3 20 28.0 0.0 19.9 0.0 4.2 120 FTG T FE -0.9 20A 30.0 0.0 19.3 0.0 0.015 TL 18.47 PV Pipe: 71 85.0 2.635 PL 2.00 PF 0.4 21 28.0 0.0 25.6 0.0 5.0 120 FTG T FE -0.9 21A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 72 11.6 2.635 FL 2.00 PF 0.0 22 28.0 0.0 19.9 0.0 0.7 120 FTG T FE -0.9 22A 30.0 0.0 19.0 0.0 0.001 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006_1.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 73 84.9 2.635 PL 2.00 PF 0.4 23 28.0 0.0 25.6 0.0 5.0 120 FTG T PE -0.9 23A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 74 11.4 2.635 PL 2.00 PF 0.0 24 28.0 0.0 19.9 0.0 0.7 120 FTG T FE -0.9 24A 30.0 0.0 19.0 0.0 0.001 TL 18.47 PV Pipe: 75 84.8 2.635 FL 2.00 PF 0.4 25 28.0 0.0 25.6 0.0 5.0 120 FTC T FE -0.9 25A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 76 9.7 2.635 PL 2.00 PF 0.0 26 28.0 0.0 19.9 0.0 0.6 120 FTC T FE -0.9 26A 30.0 0.0 19.0 0.0 0.000 TL 18.47 PV Pipe: 77 77.8 6.357 FL 8.00 PF 0.0 2 28.0 0.0 19.9 0.0 0.8 120 FTG ---- PE 0.0 4 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 78 154.0 6.357 PL 8.00 PF 0.0 4 28.0 0.0 19.9 0.0 1.6 120 FTC ---- FE 0.0 6 28.0 0.0 19.9 0.0 0.001 TL 8.00 PV Pipe: 79 109.0 6.357 PL 8.00 PF 0.0 6 28.0 0.0 19.9 0.0 1.1 120 FTG ---- PE 0.0 8 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 80 13.6 6.357 PL 8.00 PF 0.0 8 28.0 0.0 19.9 0.0 0.1 120 FTC ---- FE 0.0 10 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 81 -26.5 6.357 FL 8.00 PF 0.0 10 28.0 0.0 19.9 0.0 0.3 120 FTG ---- FE 0.0 12 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 82 45.6 6.357 FL 6.00 Fl 0.0 12 28.0 0.0 19.9 0.0 0.5 120 FTG ---- FE 0.0 14 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 83 -17.7 6.357 FL 8.00 PF 0.0 14 28.0 0.0 19.9 0.0 0.2 120 FTG ---- FE 0.0 16 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 84 -28.6 6.357 FL 8.00 PF 0.0 16 28.0 0.0 19.9 0.0 0.3 120 FTC ---- FE 0.0 18 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 85 -38.0 6.357 PL 8.00 PF 0.0 18 28.0 0.0 19.9 0.0 0.4 120 FTG ---- FE 0.0 20 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 86 32.7 6.357 PL 8.00 PF 0.0 20 28.0 0.0 19.9 0.0 0.3 120 FTG ---- PE 0.0 22 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 87 21.1 6.357 PL 8.00 PF 0.0 22 28.0 0.0 19.9 0.0 0.2 120 FTG ---- FE 0.0 24 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 88 9.7 6.357 PL 8.00 FE' 0.0 24 28.0 0.0 19.9 0.0 0.1 120 FTG ---- PE 0.0 26 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 89 1070.3 6.357 FL 8.00 PF 0.3 1 28.0 0.0 26.8 0.0 10.8 120 FTG ---- FE 0.0 3 28.0 0.0 26.5 0.0 0.032 TL 8.00 PV Pipe: 90 994.1 6.357 FL 8.00 FE' 0.2 3 28.0 0.0 26.5 0.0 10.0 120 FTG ---- PE 0.0 5 28.0 0.0 26.3 0.0 0.028 TL 8.00 PV Pipe: 91 897.7 6.357 PL 8.00 PF 0.2 5 28.0 0.0 26.3 0.0 9.1 120 FTG ---- FE 0.0 7 28.0 0.0 26.1 0.0 0.023 TL 8.00 PV Pipe: 92 781.8 6.357 PL 8.00 PF 0.1 7 28.0 0.0 26.1 0.0 7.9 120 FTG ---- FE 0.0 9 28.0 0.0 26.0 0.0 0.018 TL 8.00 PV Pipe: 93 682.5 6.357 PL 8.00 PF 0.1 9 28.0 0.0 26.0 0.0 6.9 120 FTG ---- PE 0.0 11 28.0 0.0 25.9 0.0 0.014 TL 8.00 PV Pipe: 94 610.4 6.357 FL 8.00 FE' 0.1 11 28.0 0.0 25.9 0.0 6.2 120 FTG ---- FE 0.0 13 28.0 0.0 25.8 0.0 0.011 TL 8.00 PV Pipe: 95 496.3 6.357 FL 8.00 PF 0.1 13 28.0 0.0 25.8 0.0 5.0 120 FTG ---- FE 0.0 15 28.0 0.0 25.7 0.0 0.008 TL 8.00 PV Pipe: 96 410.6 6.357 PL 8.00 FE' 0.0 15 28.0 0.0 25.7 0.0 4.2 120 FTG ---- PE 0.0 17 28.0 0.0 25.7 0.0 0.005 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006_1.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 97 325.4 6.357 PL 8.00 PF 0.0 17 28.0 0.0 25.7 0.0 3.3 120 FTG ---- PE 0.0 19 28.0 0.0 25.6 0.0 0.004 TL 8.00 PV Pipe: 98 254.7 6.357 PL 8.00 PF 0.0 19 28.0 0.0 25.6 0.0 2.6 120 FTG ---- PE 0.0 21 28.0 0.0 25.6 0.0 0.002 TL 8.00 PV Pipe: 99 169.7 6.357 FL 8.00 PF 0.0 21 28.0 0.0 25.6 0.0 1.7 120 FTG ---- FE 0.0 23 28.0 0.0 25.6 0.0 0.001 TL 8.00 PV Pipe: 100 84.8 6.357 PL 8.00 PF 0.0 23 28.0 0.0 25.6 0.0 0.9 120 FTG ---- PE 0.0 25 28.0 0.0 25.6 0.0 0.000 TL 8.00 PV Pipe: 101 77.8 2.635 PL 312.00 PF 6.2 1A 30.0 0.0 25.6 0.0 4.6 120 FTG 2T FE 0.0 2A 30.0 0.0 19.3 0.0 0.018 TL 344.95 PV Pipe: 102 76.2 2.635 PL 312.00 FE 6.0 3A 30.0 0.0 25.3 0.0 4.5 120 FTG 2T FE 0.0 4A 30.0 0.0 19.3 0.0 0.017 TL 344.95 PV Pipe: 103 96.4 2.635 PL 227.33 PF 6.6 5A 30.0 0.0 24.9 0.0 5.7 120 FTG T FE 0.0 B03 30.0 0.0 18.4 0.0 0.027 TL 243.80 PV Pipe: 104 49.2 2.635 FL 8.00 FE 0.1 B03 30.0 0.0 18.4 0.0 2.9 120 FTG ---- FE 0.0 B02 30.0 0.0 18.3 0.0 0.008 TL 8.00 PV Pipe: 105 2.1 2.635 FL 8.00 PF 0.0 B02 30.0 0.0 18.3 0.0 0.1 120 FTG ---- FE 0.0 B01 30.0 0.0 18.3 0.0 0.000 TL 8.00 PV Pipe: 106 -45.0 2.635 PL 68.67 PF 0.6 B01 30.0 0.0 18.3 0.0 2.6 120 FTG T FE 0.0 6A 30.0 0.0 18.9 0.0 0.007 TL 85.14 PV Pipe: 107 115.8 2.635 PL 195.50 PF 8.0 7A 30.0 0.0 24.6 0.0 6.8 120 FTG T FE 0.0 B21 30.0 0.0 16.5 0.0 0.038 TL 211.97 PV Pipe: 108 71.3 2.635 FL 17.00 PF 0.3 B21 30.0 0.0 16.5 0.0 4.2 120 FTG ---- FE 0.0 B20 30.0 0.0 16.3 0.0 0.015 TL 17.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 109 26.8 2.635 PL 24.00 PF 0.1 B20 30.0 0.0 16.3 0.0 1.6 120 FTG ---- PE 0.0 B05 30.0 0.0 16.2 0.0 0.003 TL 24.00 PV Pipe: 110 -50.7 2.635 PL 8.00 PF 0.1 B05 30.0 0.0 16.2 0.0 3.0 120 FTG ---- PE 0.0 B04 30.0 0.0 16.3 0.0 0.008 TL 8.00 PV Pipe: 111 -95.4 2.635 PL 67.50 PF 2.2 B04 30.0 0.0 16.3 0.0 5.6 120 FTG T PE 0.0 8A 30.0 0.0 18.5 0.0 0.026 TL 83.97 PV Pipe: 112 99.3 2.635 PL 195.50 PF 6.0 9A 30.0 0.0 24.6 0.0 5.8 120 FTG T PE 0.0 B23 30.0 0.0 18.6 0.0 0.028 TL 211.97 PV Pipe: 113 52.8 2.635 PL 17.00 PF 0.1 B23 30.0 0.0 18.6 0.0 3.1 120 FTG ---- PE 0.0 B22 30.0 0.0 18.4 0.0 0.009 TL 17.00 PV Pipe: 114 6.4 2.635 PL 24.00 PF 0.0 B22 30.0 0.0 18.4 0.0 0.4 120 FTG ---- PE 0.0 B07 30.0 0.0 18.4 0.0 0.000 TL 24.00 PV Pipe: 115 -40.1 2.635 PL 8.00 PF 0.0 B07 30.0 0.0 18.4 0.0 2.4 120 FTG ---- PE 0.0 B06 30.0 0.0 18.4 0.0 0.005 TL 8.00 PV Pipe: 116 -40.1 2.635 PL 67.50 PF 0.4 B06 30.0 0.0 18.4 0.0 2.4 120 FTG T PE 0.0 10A 30.0 0.0 18.9 0.0 0.005 TL 83.97 PV Pipe: 117 72.1 2.635 PL 312.00 PF 5.4 hA 30.0 0.0 24.7 0.0 4.2 120 FTG 2T PE 0.0 12A 30.0 0.0 19.3 0.0 0.016 TL 344.95 PV Pipe: 118 114.1 2.635 PL 195.50 PF 7.8 13A 30.0 0.0 24.2 0.0 6.7 120 FTG T PE 0.0 B25 30.0 0.0 16.4 0.0 0.037 TL 211.97 PV Pipe: 119 69.6 2.635 PL 17.00 PF 0.3 B25 30.0 0.0 16.4 0.0 4.1 120 FTG ---- PE 0.0 324 30.0 0.0 16.2 0.0 0.015 TL 17.00 PV Pipe: 120 25.4 2.635 PL 24.00 PF 0.1 B24 30.0 0.0 16.2 0.0 1.5 120 FTG ---- FE 0.0 B09 30.0 0.0 16.1 0.0 0.002 TL 24.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 15 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\4t0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 121 -18.8 2.635 PL 8.00 PF 0.0 B09 30.0 0.0 16.1 0.0 1.1 120 FTG ---- FE 0.0 B08 30.0 0.0 16.1 0.0 0.001 TL 8.00 PV Pipe: 122 -63.3 2.635 PL 195.50 PF 2.6 B08 30.0 0.0 16.1 0.0 3.7 120 FTG T FE 0.0 14A 30.0 0.0 18.8 0.0 0.012 TL 211.97 PV Pipe: 123 85.7 2.635 PL 236.50 PF 5.5 15A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 Bli 30.0 0.0 19.0 0.0 0.022 TL 252.97 PV Pipe: 124 37.3 2.635 PL 8.00 PF 0.0 Bli 30.0 0.0 19.0 0.0 2.2 120 FTG ---- FE 0.0 B10 30.0 0.0 18.9 0.0 0.005 TL 8.00 PV Pipe: 125 -10.9 2.635 FL 67.50 PF 0.0 B10 30.0 0.0 18.9 0.0 0.6 120 FTG T FE 0.0 16A 30.0 0.0 19.0 0.0 0.000 TL 83.97 PV Pipe: 126 85.2 2.635 FL 236.50 PF 5.4 17A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 B13 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 127 38.0 2.635 FL 8.00 PF 0.0 B13 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 B12 30.0 0.0 19.0 0.0 0.005 TL 8.00 PV Pipe: 128 -9.3 2.635 FL 67.50 PF 0.0 B12 30.0 0.0 19.0 0.0 0.5 120 FTG T FE 0.0 18A 30.0 0.0 19.0 0.0 0.000 TL 83.97 PV Pipe: 129 70.7 2.635 PL 312.00 PF 5.2 19A 30.0 0.0 24.5 0.0 4.2 120 FTG 2T FE 0.0 20A 30.0 0.0 19.3 0.0 0.015 TL 344.95 PV Pipe: 130 85.0 2.635 PL 236.50 PF 5.4 21A 30.0 0.0 24.4 0.0 5.0 120 FTG T FE 0.0 B15 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 131 36.7 2.635 FL 8.00 PF 0.0 B15 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 B14 30.0 0.0 18.9 0.0 0.005 TL 8.00 PV Pipe: 132 -11.6 2.635 FL 67.50 PF 0.0 B14 30.0 0.0 18.9 0.0 0.7 120 FTG T PE 0.0 22A 30.0 0.0 19.0 0.0 0.001 TL 83.97 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 16 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 133 94.9 2.635 PL 236.50 PF 5.4 23A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 B17 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 134 36.7 2.635 PL 8.00 PF 0.0 B17 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 816 30.0 0.0 18.9 0.0 0.005 TL 8.00 PV Pipe: 135 -11.4 2.635 PL 67.50 PF 0.0 BiG 30.0 0.0 18.9 0.0 0.7 120 FTG T PE 0.0 24A 30.0 0.0 19.0 0.0 0.001 TL 83.97 PV Pipe: 136 84.8 2.635 PL 236.50 PF 5.4 25A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 819 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 137 37.6 2.635 PL 8.00 PF 0.0 B19 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 818 30.0 0.0 19.0 0.0 0.005 TL 8.00 PV Pipe: 138 -9.7 2.635 PL 67.50 PF 0.0 818 30.0 0.0 19.0 0.0 0.6 120 FTC T PE 0.0 26A 30.0 0.0 19.0 0.0 0.000 TL 83.97 PV Pipe: 139 -1148.1 6.357 PL 80.00 PF 4.1 1 28.0 0.0 26.8 0.0 11.6 120 FTG 3L PE 0.0 95 28.0 0.0 30.9 0.0 0.036 TL 113.95 PV Pipe: 140 -1148.1 8.249 PL 25.00 PF 1.2 95 28.0 0.0 30.9 0.0 6.9 120 FTG TBA PE 10.8 96 3.0 H.S. 42.9 100.0 0.010 TL 116.61 PV Pipe: 141 -1248.1 8.249 PL 2.00 PF 0.5 96 3.0 H.S. 42.9 100.0 7.5 120 FTG T PE 0.9 97 1.0 0.0 44.3 0.0 0.012 TL 43.11 PV Pipe: 305 -1248.1 8.510 PL 50.00 PF 0.6 97 1.0 0.0 44.3 0.0 7.0 140 FTG LG PE 1.7 98 -3.0 0.0 46.6 0.0 0.008 TL 80.91 PV Pipe: 306 FIXED PRESSURE LOSS DEVICE 99 -3.0 0.0 51.6 0.0 5.0 psi, 1248.1 gpm 98 -3.0 0.0 46.6 0.0 Pipe: 307 -1248.1 10.520 PL 425.00 PF 1.5 99 -3.0 0.0 51.6 0.0 4.6 140 FTG T2L PE 0.0 100 -3.0 H.S. 53.2 400.0 0.003 TL 563.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 17 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 308 -1648.1 10.520 PL 160.00 PF 1.1 100 -3.0 H.S. 53.2 400.0 6.1 140 FTG T PE 0.0 101 -3.0 0.0 54.3 0.0 0.005 TL 244.30 PV Pipe: 309 -1648.1 10.520 FL 288.00 PF 1.3 101 -3.0 0.0 54.3 0.0 6.1 140 FTG ---- PE 0.0 102 -3.0 SRCE 55.6 (N/A) 0.005 TL 288.00 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38050722 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.163 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.6 ft/sec at pipe 30. Available pressure at source node 102 under full flow conditions is 58.45 psi with a flow of 1691.52 gpm. PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: * MATERIAL: S40 HNC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil ChkVlv BfyVlv GatVlv AlinChk DPVlv NPTee 2.635 8.24 16.47 5.49 19.22 9.61 1.37 13.73 13.73 16.47 6.357 17.60 37.72 11.32 40.23 12.57 3.77 35.21 35.21 37.72 9.249 21.14 41.11 15.27 52.85 14.09 4.70 36.41 36.41 41.11 8.510 24.60 47.84 17.77 61.51 16.40 5.47 42.37 42.37 47.84 10.520 27.89 63.38 20.28 69.72 24.08 6.34 46.90 46.90 63.38 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 18 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEii ChkVlv BfyVlv GatVlv AimChk DFViv Tee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 G A 60.0 U G S 50.0 80.0 70.0 P R E S S U R S P 20.0 S i 10.0 0.0 -14. 40.0 30.0 WATER SUPPLY ANALYSIS Static: 63.00 psi Resid: 40.00 psi Flow: 4060.0 gpin MM Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 20 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS WATER SUPPLY CURVE 72+ 66+ *\ 60+ \ I \ Ix \ 54+ \ I \\ I \ I \ P 48+ \ R I \\ E I S I \ S 42+ \ U I <-40.0 psi @ 4060 gpm R I Flow Test Point E I 36+ ( I P I S I I 30+ ) I 24+ 18+ 12+ LEGEND X = Required Water Supply 55.60 psi @ 1648.1 gpm ' 6+ I 0 = Available Water Supply I 58.66 psi @ 1648.1 gpm +------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) LINDLEY FIRE PROTECTION CO. 1109 N. ARMANDO STREET ANAHEIM, CA 714-535-5761 LIC. # C161C34 NO. 1037930 HYDRAULIC CALCULATIONS FOR COSTCO #462 CARLSBAD 951 PALOMAR AIRPORT ROAD CARLSBAD, CA 92011 REMOTE AREA #2- PRODUCE COOLER DATE: 05-31-2020 7 -DESIGN DATA- SYSTEM DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (INCLUDING HOSE) FLOW AND PRESSURE & BASE OF RISER: SPRINKLER ORIFICE SIZE: .385 GPM/SQ. FT. 2,000 S.F. 93.0 SQ. FT. 27 SPRINKLERS 1092.7 GPM 1592.7 GPM 1092.7 GPM @ 53.9 PSI 3/4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE, #2/Produce WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQtD NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 102 63.0 40.0 4060.0 58.9 1592.7 53.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1592.7 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 500.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 1092.7 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) DP26 22.2 K=11.20 14.0 41.9 D227 22.2 K=11.20 14.0 41.9 DP28 22.2 K=11.20 13.9 41.8 DP29 22.2 K=11.20 13.6 41.4 DP30 22.2 K=11.20 10.9 37.0 DP31 22.2 K=11.20 10.9 37.0 DP32 22.2 K=11.20 12.7 39.9 DP33 22.2 K=11.20 13.1 40.5 DP34 22.2 K=11.20 12.8 40.1 D235 22.2 K=11.20 13.5 41.2 DP36 22.2 K=11.20 13.8 41.6 DP37 22.2 K=11.20 13.7 41.4 DP38 22.2 K=11.20 13.4 41.0 DP39 22.2 K=11.20 13.0 40.4 DP40 22.2 K=11.20 13.1 40.6 DP41 22.5 K=11.20 12.9 40.2 DP42 22.5 K=11.20 12.7 39.9 DP43 22.5 K11.20 12.5 39.6 0F44 22. ic=11.20 1.4 41.0 DP45 22.5 K=11.20 13.6 41.3 DP46 22.5 K=11.20 13.5 41.2 DP47 22.5 K=11.20 13.3 40.8 DP48 22.5 K=11.20 12.9 40.3 DP49 22.5 K=11.20 13.2 40.7 DP50 22.5 K=11.20 13.1 40.6 DP51 22.5 K=11.20 12.7 39.9 DP52 22.5 K=11.20 12.5 39.6 A26 30.5 - - - - 11.9 - - - A27 30.5 - - - - 11.9 - - - A28 30.5 - - - - 11.8 - - - A29 30.5 - - - - 11.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A30 30.5 - - - - 8.5 - - - A31 30.5 - - - - 12.9 - - - A32 30.5 - - - - 10.5 A33 30.5 - - - - 10.9 - - - A34 30.5 - - - - 10.7 - - - A35 30.5 - - - - 11.4 A36 30.5 - - - 11.7 - - - A37 30.5 - - - - 11.6 - - - A38 30.5 - - - - 11.3 A39 30.5 - - - - 10.8 - - - A40 30.5 - - - - 11.0 - - A41 30.5 - - - - 10.8 - - - A42 30.5 - - - 10.6 - - - A43 30.5 - - - - 10.4 - - - A44 30.5 - - - - 11.4 - - - A45 30.5 - - - - 11.6 - - - A46 30.5 - - - - 11.5 - - - A47 30.5 - - - - 11.2 - - - A48 30.5 - - - - 10.9 - - - A49 30.5 - - - - 11.1 - - - A50 30.5 - - - - 11.1 - - - A51 30.5 - - - - 10.6 - - - A52 30.5 - - - - 10.4 B26 30.0 - - - - 13.5 - - - B27 30.0 - - - - 13.5 - - - B28 30.0 - - - - 13.4 - - - B29 30.0 - - - - 13.3 - - - 830 30.0 - - - - 13.0 - - - 831 30.0 - - - - 13.1 B32 30.0 - - - - 12.7 B33 30.0 - - - - 12.5 - - - B34 30.0 - - - - 12.5 - - - B35 30.0 - - - - 13.5 - - - 836 30.0 - - - - 13.5 - - - B37 30.0 - - - - 13.4 B38 30.0 - - - - 13.3 - - - B39 30.0 - - - - 12.9 - - - B40 30.0 - - - - 13.0 - - B41 30.0 - - - - 12.6 - - - 542 30.0 - - - - 12.4 - - - B43 30.0 - - - - 12.4 - - - 844 30.0 - - - - 13.5 B45 30.0 - - - - 13.6 - - - B46 30.0 - - - - 13.4 - - - 847 30.0 - - - - 13.4 - - - B48 30.0 - - - - 13.0 - - - B49 30.0 - - - - 13.0 - - - 850 30.0 - - - - 12.6 - - - 851 30.0 - - - - 12.5 -- - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) B52 30.0 - - - - 12.4 - - - 1 28.0 - - - - 25.9 - - - 1A 30.0 - - - - 24.6 - - - 2 28.0 - - - - 17.1 - - - 2A 30.0 - - - - 16.7 - - - 3 28.0 - - - - 25.7 - - - 3A 30.0 - - - - 24.4 - - - 4 28.0 - - - - 17.2 - - - 4A 30.0 - - - - 16.7 - - - 5 28.0 - - - - 25.5 - - - 5A 30.0 - - - - 24.2 - - - 6 28.0 - - - - 17.2 - - - 6A 30.0 - - - - 16.7 - - - 7 28.0 - - - - 25.3 7A 30.0 - - - - 24.1 - - - 8 28.0 - - - - 17.2 - - - 8A 30.0 - - - - 16.7 - - - 9 28.0 - - - - 25.2 - - - 9A 30.0 - - - - 23.9 - - - 10 28.0 - - - - 17.2 - - - 10A 30.0 - - - - 16.7 - - - 11 28.0 - - - - 25.1 - - - hA 30.0 - - - - 23.8 - - - 12 28.0 - - - - 17.2 - - - 12A 30.0 - - - - 16.7 - - - 13 28.0 - - - - 25.0 - - - 13A 30.0 - - - - 23.7 - - - 14 28.0 - - - - 17.2 - - - 14A 30.0 - - - - 16.7 - - - 15 28.0 - - - - 24.9 - - - 15A 30.0 - - - - 23.7 16 28.0 - - - - 17.2 - - - 16A 30.0 - - - - 16.7 - - - 17 28.0 - - - - 24.9 - - - 17A 30.0 - - - - 23.6 - - - 18 28.0 - - - - 17.2 - - - IBA 30.0 - - - - 16.7 - - - 19 28.0 - - - - 24.9 - - - 19A 30.0 - - - - 23.6 20 28.0 - - - - 17.2 - - - 20A 30.0 - - - - 16.7 - - - 21 28.0 - - - - 24.8 - - - 21A 30.0 - - - - 23.6 - - - 22 28.0 - - - - 17.1 - - - 22A 30.0 - - - - 16.6 - - - 23 28.0 - - - - 24.8 - - - 23A 30.0 - - - - 23.6 - - - 24 28.0 - - - - 17.1 - - - 24A 30.0 - - - - 16.6 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 25 29.0 - - - - 24.8 - - - 25A 30.0 - - - - 23.6 - - - 26 28.0 - - - - 17.0 - - - 26A 30.0 - - - - 16.5 - - - 38 28.0 - - - - 16.1 - - - 38A 30.0 - - - - 13.9 - - - 39 28.0 - - - - 16.1 - - - 39A 30.0 - - - 13.4 - - - 40 28.0 - - - - 16.1 - - - 40A 30.0 - - - - 13.9 - - - 41 28.0 - - - - 16.1 - - - 41A 30.0 - - - - 13.3 - - - 42 28.0 - - - 16.1 - - - 42A 30.0 - - - - 13.9 - - - 43 28.0 - - - - 16.2 - - - 43A 30.0 - - - - 13.4 - - - 95 28.0 - - - - 29.6 - -- 96 3.0 HOSE STREAM 41.6 100.0 97 1.0 - - - - 42.9 98 -3.0 - - - - 45.2 - - - 99 -3.0 - - - - 50.2 - - - 100 -3.0 HOSE STREAM 51.6 400.0 101 -3.0 - - - - 52.6 - - - 102 -3.0 SOURCE 53.9 1592.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -41.9 1.380 PL 8.25 PF 1.5 DP26 22.2 11.2 14.0 41.9 9.0 120 FTG E FE -3.6 A26 30.5 0.0 11.9 0.0 0.134 TL 11.25 PV Pipe: 2 -41.9 1.380 PL 8.25 PF 1.5 DP27 22.2 11.2 14.0 41.9 9.0 120 FTG E PE -3.6 A27 30.5 0.0 11.9 0.0 0.134 TL 11.25 PV Pipe: 3 -41.8 1.380 FL 8.25 RE 1.5 DP28 22.2 11.2 13.9 41.8 9.0 120 FTG E PE -3.6 A28 30.5 0.0 11.8 0.0 0.134 TL 11.25 PV Pipe: 4 -41.4 1.380 PL 8.25 PP 1.5 DP29 22.2 11.2 13.6 41.4 8.9 120 FTG E PE -3.6 A29 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 5 -37.0 1.380 PL 8.25 PP 1.2 DP30 22.2 11.2 10.9 37.0 7.9 120 FTG E PE -3.6 A30 30.5 0.0 8.5 0.0 0.107 TL 11.25 PV Pipe: 6 -37.0 1.380 PL 8.25 PF 1.2 DP31 22.2 11.2 10.9 37.0 7.9 120 FTG E PE -3.6 A30 30.5 0.0 8.5 0.0 0.107 TL 11.25 PV Pipe: 7 -39.9 1.380 FL 8.25 PF 1.4 DP32 22.2 11.2 12.7 39.9 8.6 120 FTG E PE -3.6 A32 30.5 0.0 10.5 0.0 0.123 TL 11.25 PV Pipe: 8 -40.5 1.380 PL 8.25 PF 1.4 DP33 22.2 11.2 13.1 40.5 8.7 120 FTG E FE -3.6 A33 30.5 0.0 10.9 0.0 0.126 TL 11.25 PV Pipe: 9 -40.1 1.380 FL 8.25 PF 1.4 DP34 22.2 11.2 12.8 40.1 8.6 120 FTG E PE -3.6 A34 30.5 0.0 10.7 0.0 0.124 TL 11.25 PV Pipe: 10 -41.2 1.380 PL 8.25 PF 1.5 DP35 22.2 11.2 13.5 41.2 8.8 120 FTG E FE -3.6 A35 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 11 -41.6 1.380 PL 8.25 PF 1.5 DP36 22.2 11.2 13.8 41.6 8.9 120 FTG E PE -3.6 A36 30.5 0.0 11.7 0.0 0.133 TL 11.25 PV Pipe: 12 -41.4 1.380 FL 8.25 PP 1.5 DP37 22.2 11.2 13.7 41.4 8.9 120 FTC E PE -3.6 A37 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -41.0 1.380 FL 8.25 PF 1.5 DP38 22.2 11.2 13.4 41.0 8.8 120 FTC E FE -3.6 A38 30.5 0.0 11.3 0.0 0.129 TL 11.25 PV Pipe: 14 -40.4 1.380 PL 8.25 PF 1.4 DP39 22.2 11.2 13.0 40.4 8.7 120 FTG E PE -3.6 A39 30.5 0.0 10.8 0.0 0.125 TL 11.25 PV Pipe: 15 -40.6 1.380 PL 8.25 PF 1.4 DP40 22.2 11.2 13.1 40.6 8.7 120 FTG E PE -3.6 MO 30.5 0.0 11.0 0.0 0.127 TL 11.25 PV Pipe: 16 -40.2 1.380 FL 8.25 PF 1.4 DP41 22.5 11.2 12.9 40.2 8.6 120 FTG E FE -3.5 A41 30.5 0.0 10.8 0.0 0.124 TL 11.25 PV Pipe: 17 -39.9 1.380 PL 8.25 PF 1.4 DP42 22.5 11.2 12.7 39.9 8.6 120 FTG E PE -3.5 A42 30.5 0.0 10.6 0.0 0.123 TL 11.25 PV Pipe: 18 -39.6 1.380 PL 8.25 PF 1.4 DP43 22.5 11.2 12.5 39.6 8.5 120 FTG E PE -3.5 A43 30.5 0.0 10.4 0.0 0.121 TL 11.25 PV Pipe: 19 -41.0 1.380 FL 8.25 PF 1.5 DP44 22.5 11.2 13.4 41.0 8.8 120 FTC E PE -3.5 A44 30.5 0.0 11.4 0.0 0.129 TL 11.25 PV Pipe: 20 -41.3 1.380 FL 8.25 PF 1.5 DP45 22.5 11.2 13.6 41.3 8.9 120 FTG E PE -3.5 A45 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 21 -41.2 1.380 PL 8.25 PF 1.5 DP46 22.5 11.2 13.5 41.2 8.8 120 FTG E PE -3.5 A46 30.5 0.0 11.5 0.0 0.130 TL 11.25 PV Pipe: 22 -40.8 1.380 FL 8.25 PF 1.4 DP47 22.5 11.2 13.3 40.8 8.7 120 FTG E FE -3.5 A47 30.5 0.0 11.2 0.0 0.128 TL 11.25 PV Pipe: 23 -40.3 1.380 FL 8.25 PF 1.4 DP48 22.5 11.2 12.9 40.3 8.6 120 FTG E PE -3.5 A48 30.5 0.0 10.9 0.0 0.125 TL 11.25 PV Pipe: 24 -40.7 1.380 PL 8.25 PF 1.4 DP49 22.5 11.2 13.2 40.7 8.7 120 FTC E FE -3.5 A49 30.5 0.0 11.1 0.0 0.127 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 -40.6 1.380 FL 8.25 PF 1.4 DP50 22.5 11.2 13.1 40.6 8.7 120 FTG E FE -3.5 A50 30.5 0.0 11.1 0.0 0.127 TL 11.25 PV Pipe: 25A -39.9 1.380 PL 8.25 PF 1.4 DP51 22.5 11.2 12.7 39.9 8.6 120 FTG E PE -3.5 A51 30.5 0.0 10.6 0.0 0.123 TL 11.25 PV Pipe: 25B -39.6 1.380 PL 8.25 PF 1.4 DP52 22.5 11.2 12.5 39.6 8.5 120 FTG E FE -3.5 A52 30.5 0.0 10.4 0.0 0.121 TL 11.25 PV Pipe: 26 -41.9 1.380 FL 1.00 PF 1.3 A26 30.5 0.0 11.9 0.0 9.0 120 FTG ET PE 0.2 B26 30.0 0.0 13.5 0.0 0.134 TL 10.00 PV Pipe: 27 -41.9 1.380 FL 1.00 PF 1.3 A27 30.5 0.0 11.9 0.0 9.0 120 FTG ET PE 0.2 B27 30.0 0.0 13.5 0.0 0.134 TL 10.00 PV Pipe: 28 -41.8 1.380 FL 1.00 PF 1.3 A28 30.5 0.0 11.8 0.0 9.0 120 FTG ET PE 0.2 B28 30.0 0.0 13.4 0.0 0.134 TL 10.00 PV Pipe: 29 -41.4 1.380 FL 3.00 PF 1.6 A29 30.5 0.0 11.5 0.0 8.9 120 FTG ET FE 0.2 B29 30.0 0.0 13.3 0.0 0.131 TL 12.00 PV Pipe: 30 -74.0 1.380 PL 2.00 PF 4.2 A30 30.5 0.0 8.5 0.0 15.9 120 FTG ET FE 0.2 B30 30.0 0.0 13.0 0.0 0.385 TL 11.00 PV Pipe: 31 0.0 1.380 PL 2.00 PF 0.0 A31 30.5 0.0 12.9 0.0 0.0 120 FTG ET FE 0.2 B31 30.0 0.0 13.1 0.0 0.000 TL 11.00 PV Pipe: 32 -39.9 1.380 FL 7.00 PF 2.0 A32 30.5 0.0 10.5 0.0 8.6 120 FTG ET PE 0.2 B32 30.0 0.0 12.7 0.0 0.123 TL 16.00 PV Pipe: 33 -40.5 1.380 FL 2.00 PF 1.4 A33 30.5 0.0 10.9 0.0 8.7 120 FTG ET PE 0.2 B33 30.0 0.0 12.5 0.0 0.126 TL 11.00 PV Pipe: 34 -40.1 1.380 FL 4.00 PF 1.6 A34 30.5 0.0 10.7 0.0 8.6 120 FTG ET FE 0.2 B34 30.0 0.0 12.5 0.0 0.124 TL 13.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/19/2018 C:\PROGRAM FILES\}IRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (ET) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 35 -41.2 1.380 PL 5.00 PF 1.8 A35 30.5 0.0 11.4 0.0 8.8 120 FTG ET PE 0.2 B35 30.0 0.0 13.5 0.0 0.130 TL 14.00 PV Pipe: 36 -41.6 1.380 PL 3.00 FE' 1.6 A36 30.5 0.0 11.7 0.0 '8.9 120 FTG ET PE 0.2 B36 30.0 0.0 13.5 0.0 0.133 TL 12.00 PV Pipe: 37 -41.4 1.380 PL 3.00 FE' 1.6 A37 30.5 0.0 11.6 0.0 8.9 120 FTG ET FE 0.2 B37 30.0 0.0 13.4 0.0 0.131 TL 12.00 PV Pipe: 38 -41.0 1.380 FL 5.00 PF 1.8 A38 30.5 0.0 11.3 0.0 8.8 120 FTG ET FE 0.2 B38 30.0 0.0 13.3 0.0 0.129 TL 14.00 PV Pipe: 39 -40.4 1.380 FL 6.00 PF 1.9 A39 30.5 0.0 10.8 0.0 8.7 120 FTG ET FE 0.2 B39 30.0 0.0 12.9 0.0 0.125 TL 15.00 PV Pipe: 40 -40.6 1.380 FL 5.00 FE' 1.8 A40 30.5 0.0 11.0 0.0 8.7 120 FTG ET FE 0.2 B40 30.0 0.0 13.0 0.0 0.127 TL 14.00 PV Pipe: 41 -40.2 1.380 FL 4.00 PF 1.6 A41 30.5 0.0 10.8 0.0 8.6 120 FTG ET FE 0.2 B41 30.0 0.0 12.6 0.0 0.124 TL 13.00 PV Pipe: 42 -39.9 1.380 FL 4.00 PF 1.6 A42 30.5 0.0 10.6 0.0 8.6 120 FTG ET PE 0.2 B42 30.0 0.0 12.4 0.0 0.123 TL 13.00 PV Pipe: 43 -39.6 1.380 FL 6.00 PF 1.8 A43 30.5 0.0 10.4 0.0 8.5 120 FTG ET FE 0.2 B43 30.0 0.0 12.4 0.0 0.121 TL 15.00 PV Pipe: 44 -41.0 1.380 PL 6.00 PF 1.9 A44 30.5 0.0 11.4 0.0 8.8 120 FTC ET FE 0.2 B44 30.0 0.0 13.5 0.0 0.129 TL 15.00 PV Pipe: 45 -41.3 1.380 PL 4.00 PF 1.7 A45 30.5 0.0 11.6 0.0 8.9 120 FTG ET FE 0.2 B45 30.0 0.0 13.6 0.0 0.131 TL 13.00 PV Pipe: 46 -41.2 1.380 FL 4.00 FE 1.7 A46 30.5 0.0 11.5. 0.0 8.8 120 FTC ET FE 0.2 B46 30.0 0.0 13.4 0.0 0.130 TL 13.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\FIASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 47 -40.8 1.380 FL 6.00 PF 1.9 A47 30.5 0.0 11.2 0.0 8.7 120 FTG ET PE 0.2 B47 30.0 0.0 13.4 0.0 0.128 TL 15.00 PV Pipe: 48 -40.3 1.380 FL 6.00 PF 1.9 A48 30.5 0.0 10.9 0.0 8.6 120 FTG ET PE 0.2 B48 30.0 0.0 13.0 0.0 0.125 TL 15.00 PV Pipe: 49 -40.7 1.380 FL 4.00 PF 1.7 A49 30.5 0.0 11.1 0.0 8.7 120 FTG ET FE 0.2 B49 30.0 0.0 13.0 0.0 0.127 TL 13.00 PV Pipe: 50 -40.6 1.380 PL 1.00 PF 1.3 A50 30.5 0.0 11.1 0.0 8.7 120 FTG ET PE 0.2 B50 30.0 0.0 12.6 0.0 0.127 TL 10.00 PV Pipe: 50A -39.9 1.380 PL 4.00 PF 1.6 A51 30.5 0.0 10.6 0.0 8.6 120 FTG ET PE 0.2 B51 30.0 0.0 12.5 0.0 0.123 TL 13.00 PV Pipe: 50B -39.6 1.380 FL 6.00 PF 1.8 A52 30.5 0.0 10.4 0.0 8.5 120 FTG ET FE 0.2 B52 30.0 0.0 12.4 0.0 0.121 TL 15.00 PV Pipe: 51 88.5 2.635 FL 2.00 PF 0.4 1 28.0 0.0 25.9 0.0 5.2 120 FTG T FE -0.9 1A 30.0 0.0 24.6 0.0 0.023 TL 18.47 PV Pipe: 52 -88.5 2.635 FL 2.00 PF 0.4 2 28.0 0.0 17.1 0.0 5.2 120 FTG T FE -0.9 2A 30.0 0.0 16.7 0.0 0.023 TL 18.47 PV Pipe: 53 87.0 2.635 PL 2.00 PF 0.4 3 28.0 0.0 25.7 0.0 5.1 120 FTG T PH -0.9 3A 30.0 0.0 24.4 0.0 0.022 TL 18.47 PV Pipe: 54 -87.0 2.635 PL 2.00 PF 0.4 4 28.0 0.0 17.2 0.0 5.1 120 FTG T FE -0.9 4A 30.0 0.0 16.7 0.0 0.022 TL 18.47 PV Pipe: 55 85.8 2.635 PL 2.00 PF 0.4 5 28.0 0.0 25.5 0.0 5.0 120 FTG T FE -0.9 5A 30.0 0.0 24.2 0.0 0.022 TL 18.47 PV Pipe: 56 -85.8 2.635 FL 2.00 PF 0.4 6 28.0 0.0 17.2 0.0 5.0 120 FTG T FE -0.9 6A 30.0 0.0 16.7 0.0 0.022 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 57 84.8 2.635 FL 2.00 PF 0.4 7 28.0 0.0 25.3 0.0 5.0 120 FTG T PE -0.9 7A 30.0 0.0 24.1 0.0 0.021 TL 18.47 PV Pipe: 58 -84.8 2.635 PL 2.00 PF 0.4 8 28.0 0.0 17.2 0.0 5.0 120 FTG T FE -0.9 8A 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 59 84.1 2.635 PL 2.00 PF 0.4 9 28.0 0.0 25.2 0.0 4.9 120 FTG T PE -0.9 9A 30.0 0.0 23.9 0.0 0.021 TL 18.47 PV Pipe: 60 -84.1 2.635 PL 2.00 PF 0.4 10 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 bA 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 61 83.5 2.635 FL 2.00 PF 0.4 11 28.0 0.0 25.1 0.0 4.9 120 FTC T FE -0.9 hA 30.0 0.0 23.8 0.0 0.021 TL 18.47 PV Pipe: 62 -83.5 2.635 FL 2.00 PF 0.4 12 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 12A 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 63 83.0 2.635 FL 2.00 PF 0.4 13 28.0 0.0 25.0 0.0 4.9 120 FTG T PE -0.9 13A 30.0 0.0 23.7 0.0 0.020 TL 18.47 PV Pipe: 64 -83.0 2.635 FL 2.00 PF 0.4 14 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 14A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV Pipe: 65 82.7 2.635 PL 2.00 PF 0.4 15 28.0 0.0 24.9 0.0 4.9 120 FTC T FE -0.9 iSA 30.0 0.0 23.7 0.0 0.020 TL 18.47 PV Pipe: 66 -82.7 2.635 FL 2.00 PF 0.4 16 28.0 0.0 17.2 0.0 4.9 120 FTG T FE -0.9 16A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV Pipe: 67 82.5 2.635 PL 2.00 FE' 0.4 17 28.0 0.0 24.9 0.0 4.9 120 FTG T FE -0.9 17A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 68 -82.5 2.635 FL 2.00 FE' 0.4 18 28.0 0.0 17.2 0.0 4.9 120 FTG T FE -0.9 18A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/19/2018 C:\FROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 69 82.4 2.635 FL 2.00 PF 0.4 19 28.0 0.0 24.9 0.0 4.8 120 FTG T PE -0.9 19A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 70 -82.4 2.635 PL 2.00 PF 0.4 20 28.0 0.0 17.2 0.0 4.8 120 FTG T FE -0.9 20A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV Pipe: 71 82.5 2.635 FL 2.00 PF 0.4 21 28.0 0.0 24.8 0.0 4.9 120 FTG T FE -0.9 21A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 72 -82.5 2.635 FL 2.00 PF 0.4 22 28.0 0.0 17.1 0.0 4.9 120 FTG T FE -0.9 22A 30.0 0.0 16.6 0.0 0.020 TL 18.47 PV Pipe: 73 82.8 2.635 FL 2.00 PF 0.4 23 28.0 0.0 24.8 0.0 4.9 120 FTG T FE -0.9 23A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 74 -82.8 2.635 FL 2.00 PF 0.4 24 28.0 0.0 17.1 0.0 4.9 120 FTG T FE -0.9 24A 30.0 0.0 16.6 0.0 0.020 TL 18.47 PV Pipe: 75 83.1 2.635 FL 2.00 PF 0.4 25 28.0 0.0 24.8 0.0 4.9 120 FTG T FE -0.9 25A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 76 -83.1 2.635 PL 2.00 PF 0.4 26 28.0 0.0 17.0 0.0 4.9 120 FTG T FE -0.9 26A 30.0 0.0 16.5 0.0 0.020 TL 18.47 PV Pipe: 76A 166.9 2.635 PL 2.00 PF 1.4 38 28.0 0.0 16.1 0.0 9.8 120 FTG T PE -0.9 38A 30.0 0.0 13.9 0.0 0.074 TL 18.47 PV Pipe: 76B 194.6 2.635 FL 2.00 PF 1.0 39 28.0 0.0 16.1 0.0 11.4 120 FTG T FE -0.9 39A 30.0 0.0 13.4 0.0 0.099 TL 18.47 PV Pipe: 76C 165.3 2.635 FL 2.00 PF 1.3 40 28.0 0.0 16.1 0.0 9.7 120 FTG T FE -0.9 40A 30.0 0.0 13.9 0.0 0.073 TL 18.47 PV Pipe: 76D 200.6 2.635 FL 2.00 PF 1.9 41 28.0 0.0 16.1 0.0 11.8 120 FTG T FE -0.9 41A 30.0 0.0 13.3 0.0 0.104 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 10/19/2018 C:\PROGRAM FILES\I-IRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 76E 164.3 2.635 FL 2.00 PF 1.3 42 28.0 0.0 16.1 0.0 9.7 120 FTG T FE -0.9 42A 30.0 0.0 13.9 0.0 0.072 TL 18.47 PV Pipe: 76F 201.1 2.635 PL 2.00 PF 1.9 43 28.0 0.0 16.2 0.0 11.8 120 FTG T PE -0.9 43A 30.0 0.0 13.4 0.0 0.105 TL 18.47 PV Pipe: 77 -396.1 6.357 PL 8.00 PF 0.0 2 28.0 0.0 17.1 0.0 4.0 120 FTG ---- PE 0.0 4 28.0 0.0 17.2 0.0 0.005 TL 8.00 PV Pipe: 78 -309.1 6.357 FL 8.00 PF 0.0 4 28.0 0.0 17.2 0.0 3.1 120 FTG ---- FE 0.0 6 28.0 0.0 17.2 0.0 0.003 TL 8.00 PV Pipe: 79 -223.3 6.357 FL 8.00 PF 0.0 6 28.0 0.0 17.2 0.0 2.3 120 FTG ---- FE 0.0 8 28.0 0.0 17.2 0.0 0.002 TL 8.00 PV Pipe: 80 -138.5 6.357 PL 8.00 PF 0.0 8 28.0 0.0 17.2 0.0 1.4 120 FTG ---- FE 0.0 10 28.0 0.0 17.2 0.0 0.001 TL 8.00 PV Pipe: 81 -54.4 6.357 FL 8.00 PF 0.0 10 28.0 0.0 17.2 0.0 0.5 120 FTG ---- FE 0.0 12 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 82 29.1 6.357 PL 8.00 PF 0.0 12 28.0 0.0 17.2 0.0 0.3 120 FTG ---- FE 0.0 14 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 83 112.1 6.357 FL 8.00 PF 0.0 14 28.0 0.0 17.2 0.0 1.1 120 FTC ---- FE 0.0 16 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 84 194.7 6.357 FL 8.00 PF 0.0 16 28.0 0.0 17.2 0.0 2.0 120 FTG ---- PE 0.0 18 28.0 0.0 17.2 0.0 0.001 TL 8.00 PV Pipe: 85 277.2 6.357 PL 8.00 PF 0.0 18 28.0 0.0 17.2 0.0 2.8 120 FTG ---- FE 0.0 20 28.0 0.0 17.2 0.0 0.003 TL 8.00 PV Pipe: 86 359.6 6.357 PL 8.00 PF 0.0 20 28.0 0.0 17.2 0.0 3.6 120 FTG ---- FE 0.0 22 28.0 0.0 17.1 0.0 0.004 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 87 442.2 6.357 PL 8.00 PF 0.0 22 28.0 0.0 17.1 0.0 4.5 120 FTG ---- PH 0.0 24 28.0 0.0 17.1 0.0 0.006 TL 8.00 PV Pipe: 88 524.9 6.357 PL 8.00 PF 0.1 24 28.0 0.0 17.1 0.0 5.3 120 FTC ---- PE 0.0 26 28.0 0.0 17.0 0.0 0.008 TL 8.00 PV Pipe: 89 1004.2 6.357 PL 8.00 PF 0.2 1 28.0 0.0 25.9 0.0 10.2 120 FTC ---- PE 0.0 3 28.0 0.0 25.7 0.0 0.028 TL 8.00 PV Pipe: 90 917.2 6.357 PL 8.00 PF 0.2 3 28.0 0.0 25.7 0.0 9.3 120 FTG ---- PE 0.0 5 28.0 0.0 25.5 0.0 0.024 TL 8.00 PV Pipe: 91 831.4 6.357 FL 8.00 PP 0.2 5 28.0 0.0 25.5 0.0 8.4 120 FTG ---- FE 0.0 7 28.0 0.0 25.3 0.0 0.020 TL 8.00 PV Pipe: 92 746.5 6.357 FL 8.00 PF 0.1 7 28.0 0.0 25.3 0.0 7.5 120 FTC ---- PE 0.0 9 28.0 0.0 25.2 0.0 0.016 TL 8.00 PV Pipe: 93 662.5 6.357 PL 8.00 PF 0.1 9 28.0 0.0 25.2 0.0 6.7 120 FTC ---- FE 0.0 11 28.0 0.0 25.1 0.0 0.013 TL 8.00 PV Pipe: 94 579.0 6.357 PL 8.00 PF 0.1 11 28.0 0.0 25.1 0.0 5.9 120 FTC ---- FE 0.0 13 28.0 0.0 25.0 0.0 0.010 TL 8.00 PV Pipe: 95 496.0 6.357 PL 8.00 PF 0.1 13 28.0 0.0 25.0 0.0 5.0 120 FTC ---- PE 0.0 15 28.0 0.0 24.9 0.0 0.008 TL 8.00 PV Pipe: 96 413.3 6.357 PL 6.00 PF 0.0 15 28.0 0.0 24.9 0.0 4.2 120 FTG ---- FE 0.0 17 28.0 0.0 24.9 0.0 0.005 TL 8.00 PV Pipe: 97 330.9 6.357 PL 8.00 PP 0.0 17 28.0 0.0 24.9 0.0 3.3 120 FTG ---- PH 0.0 19 28.0 0.0 24.9 0.0 0.004 TL 8.00 PV Pipe: 98 248.4 6.357 PL 8.00 PF 0.0 19 28.0 0.0 24.9 0.0 2.5 120 FTC ---- PE 0.0 21 28.0 0.0 24.8 0.0 0.002 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 99 165.9 6.357 PL 8.00 PF 0.0 21 28.0 0.0 24.8 0.0 1.7 120 FTG ---- PE 0.0 23 28.0 0.0 24.8 0.0 0.001 TL 8.00 PV Pipe: 100 83.1 6.357 PL 8.00 PF 0.0 23 28.0 0.0 24.8 0.0 0.8 120 FTG ---- PE 0.0 25 28.0 0.0 24.8 0.0 0.000 TL 8.00 PV Pipe: bOA 317.7 6.357 FL 8.00 PF 0.0 38 28.0 0.0 16.1 0.0 3.2 120 FTG ---- PE 0.0 39 28.0 0.0 16.1 0.0 0.003 TL 8.00 PV Pipe: bOB 123.1 6.357 PL 8.00 PF 0.0 39 28.0 0.0 16.1 0.0 1.2 120 FTG ---- PE 0.0 40 28.0 0.0 16.1 0.0 0.001 TL 8.00 PV Pipe: 100C -42.2 6.357 PL 8.00 PF 0.0 40 28.0 0.0 16.1 0.0 0.4 120 FTG ---- FE 0.0 41 28.0 0.0 16.1 0.0 0.000 TL 8.00 PV Pipe: 100D -242.8 6.357 FL 8.00 PF 0.0 41 28.0 0.0 16.1 0.0 2.5 120 FTG ---- PE 0.0 42 28.0 0.0 16.1 0.0 0.002 TL 8.00 PV Pipe: 100E -407.0 6.357 PL 8.00 PF 0.0 42 28.0 0.0 16.1 0.0 4.1 120 FTG ---- FE 0.0 43 28.0 0.0 16.2 0.0 0.005 TL 8.00 PV Pipe: 100F -608.1 6.357 FL 53.00 PF 0.8 43 28.0 0.0 16.2 0.0 6.1 120 FTG 2L FE 0.0 26 28.0 0.0 17.0 0.0 0.011 TL 75.63 PV Pipe: 100G -484.6 6.357 FL 110.00 PF 1.0 38 28.0 0.0 16.1 0.0 4.9 120 FTG 2L PE 0.0 2 28.0 0.0 17.1 0.0 0.007 TL 132.63 PV Pipe: 101 88.5 2.635 FL 312.00 PF 7.9 1A 30.0 0.0 24.6 0.0 5.2 120 FTG 2T FE 0.0 2A 30.0 0.0 16.7 0.0 0.023 TL 344.95 PV Pipe: 102 87.0 2.635 FL 312.00 PF 7.7 3A 30.0 0.0 24.4 0.0 5.1 120 FTG 2T FE 0.0 4A 30.0 0.0 16.7 0.0 0.022 TL 344.95 PV Pipe: 103 85.8 2.635 PL 312.00 PF 7.5 SA 30.0 0.0 24.2 0.0 5.0 120 FTG 2T FE 0.0 6A 30.0 0.0 16.7 0.0 0.022 TL 344.95 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 15 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 104 84.8 2.635 PL 312.00 PF 7.3 7A 30.0 0.0 24.1 0.0 5.0 120 FTG 2T FE 0.0 8A 30.0 0.0 16.7 0.0 0.021 TL 344.95 PV Pipe: 105 84.1 2.635 PL 312.00 PF 7.2 9A 30.0 0.0 23.9 0.0 4.9 120 FTG 2T PE 0.0 10A 30.0 0.0 16.7 0.0 0.021 TL 344.95 PV Pipe: 106 83.5 2.635 PL 312.00 PF 7.1 hA 30.0 0.0 23.8 0.0 4.9 120 FTG 2T FE 0.0 12A 30.0 0.0 16.7 0.0 0.021 TL 344.95 PV Pipe: 107 83.0 2.635 FL 312.00 PF 7.0 13A 30.0 0.0 23.7 0.0 4.9 120 FTG 2T FE 0.0 14A 30.0 0.0 16.7 0.0 0.020 TL 344.95 PV Pipe: 108 82.7 2.635 FL 312.00 PF 7.0 15A 30.0 0.0 23.7 0.0 4.9 120 FTG 2T FE 0.0 16A 30.0 0.0 16.7 0.0 0.020 TL 344.95 PV Pipe: 109 82.5 2.635 PL 312.00 PF 7.0 17A 30.0 0.0 23.6 0.0 4.9 120 FTC 2T PE 0.0 18A 30.0 0.0 16.7 0.0 0.020 TL 344.95 PV Pipe: 110 82.4 2.635 FL 312.00 PF 6.9 19A 30.0 0.0 23.6 0.0 4.8 120 FTC 2T FE 0.0 20A 30.0 0.0 16.7 0.0 0.020 TL 344.95 PV Pipe: 111 82.5 2.635 FL 312.00 PF 7.0 21A 30.0 0.0 23.6 0.0 4.9 120 FTG 2T PE 0.0 22A 30.0 0.0 16.6 0.0 0.020 TL 344.95 PV Pipe: 112 82.8 2.635 FL 312.00 PF 7.0 23A 30.0 0.0 23.6 0.0 4.9 120 FTG 2T PE 0.0 24A 30.0 0.0 16.6 0.0 0.020 TL 344.95 PV Pipe: 113 63.1 2.635 FL 312.00 FE 7.1 25A 30.0 0.0 23.6 0.0 4.9 120 FTG 2T FE 0.0 26A 30.0 0.0 16.5 0.0 0.020 TL 344.95 PV Pipe: 114 -40.3 2.635 PL 8.00 PF 0.0 B48 30.0 0.0 13.0 0.0 2.4 120 FTC ---- FE 0.0 B49 30.0 0.0 13.0 0.0 0.005 TL 8.00 PV Pipe: 115 -80.9 2.635 FL 2.00 PF 0.4 B49 30.0 0.0 13.0 0.0 4.8 120 FTC T FE 0.0 43A 30.0 0.0 13.4 0.0 0.019 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 16 DATE: 10/19/2018 C:\FROGRAM FILES\HRS SYSTEMS\HASS88\4006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 116 120.1 2.635 PL 3.00 PF 0.8 43A 30.0 0.0 13.4 0.0 7.1 120 FTG T FE 0.0 850 30.0 0.0 12.6 0.0 0.040 TL 19.47 PV Pipe: 117 79.5 2.635 PL 7.00 PF 0.1 B50 30.0 0.0 12.6 0.0 4.7 120 FTG ---- FE 0.0 B51 30.0 0.0 12.5 0.0 0.019 TL 7.00 PV Pipe: 118 39.6 2.635 PL 7.00 PF 0.0 851 30.0 0.0 12.5 0.0 2.3 120 FTG ---- PE 0.0 852 30.0 0.0 12.4 0.0 0.005 TL 7.00 PV Pipe: 119 -41.0 2.635 FL 8.00 FE' 0.0 844 30.0 0.0 13.5 0.0 2.4 120 FTG ---- FE 0.0 B45 30.0 0.0 13.6 0.0 0.006 TL 8.00 PV Pipe: 120 -82.3 2.635 FL 2.00 PF 0.4 B45 30.0 0.0 13.6 0.0 4.8 120 FTG T FE 0.0 42A 30.0 0.0 13.9 0.0 0.020 TL 18.47 PV Pipe: 121 81.9 2.635 FL 10.00 PF 0.5 42A 30.0 0.0 13.9 0.0 4.8 120 FTC T PE 0.0 B46 30.0 0.0 13.4 0.0 0.020 TL 26.47 PV Pipe: 122 40.8 2.635 PL 7.00 FE' 0.0 846 30.0 0.0 13.4 0.0 2.4 120 FTG ---- FE 0.0 B47 30.0 0.0 13.4 0.0 0.005 TL 7.00 PV Pipe: 123 -40.4 2.635 PL 8.00 FE' 0.0 B39 30.0 0.0 12.9 0.0 2.4 120 FTG ---- PE 0.0 B40 30.0 0.0 13.0 0.0 0.005 TL 8.00 PV Pipe: 124 -80.9 2.635 PL 2.00 PF 0.4 840 30.0 0.0 13.0 0.0 4.8 120 FTG T FE 0.0 41A 30.0 0.0 13.3 0.0 0.019 TL 18.47 PV Pipe: 125 119.7 2.635 FL 1.00 PF 0.7 41A 30.0 0.0 13.3 0.0 7.0 120 FTG T FE 0.0 B41 30.0 0.0 12.6 0.0 0.040 TL 17.47 PV Pipe: 126 79.5 2.635 FL 9.00 PF 0.2 B41 30.0 0.0 12.6 0.0 4.7 120 FTG ---- PE 0.0 B42 30.0 0.0 12.4 0.0 0.019 TL 9.00 PV Pipe: 127 39.6 2.635 PL 7.00 PF 0.0 842 30.0 0.0 12.4 0.0 2.3 120 FTG ---- FE 0.0 843 30.0 0.0 12.4 0.0 0.005 TL 7.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 17 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 128 -41.2 2.635 FL 8.00 PF 0.0 B35 30.0 0.0 13.5 0.0 2.4 120 FTG ---- FE 0.0 B36 30.0 0.0 13.5 0.0 0.006 TL 8.00 PV Pipe: 129 -82.8 2.635 FL 2.00 PF 0.4 B36 30.0 0.0 13.5 0.0 4.9 120 FTG T FE 0.0 40A 30.0 0.0 13.9 0.0 0.020 TL 18.47 PV Pipe: 130 82.4 2.635 FL 10.00 PF 0.5 40A 30.0 0.0 13.9 0.0 4.9 120 FTG T PE 0.0 B37 30.0 0.0 13.4 .0.0 0.020 TL 26.47 PV Pipe: 131 41.0 2.635 FL 7.00 PF 0.0 537 30.0 0.0 13.4 0.0 2.4 120 FTG ---- FE 0.0 538 30.0 0.0 13.3 0.0 0.006 TL 7.00 PV Pipe: 132 -74.0 2.635 FL 8.00 PP 0.1 B30 30.0 0.0 13.0 0.0 4.4 120 FTC ---- FE 0.0 B31 30.0 0.0 13.1 0.0 0.016 TL 8.00 PV Pipe: 133 -74.0 2.635 FL 2.00 PP 0.3 B31 30.0 0.0 13.1 0.0 4.4 120 FTG T PE 0.0 39A 30.0 0.0 13.4 0.0 0.016 TL 18.47 PV Pipe: 134 120.6 2.635 PL 1.00 PP 0.7 39A 30.0 0.0 13.4 0.0 7.1 120 FTG T FE 0.0 B32 30.0 0.0 12.7 0.0 0.041 TL 17.47 PV Pipe: 135 80.7 2.635 FL 9.00 PF 0.2 B32 30.0 0.0 12.7 0.0 4.7 120 FTG ---- FE 0.0 B33 30.0 0.0 12.5 0.0 0.019 TL 9.00 PV Pipe: 136 40.1 2.635 FL 8.00 PF 0.0 B33 30.0 0.0 12.5 0.0 2.4 120 FTG ---- FE 0.0 B34 30.0 0.0 12.5 0.0 0.005 TL 8.00 PV Pipe: 137 -41.9 2.635 ?L 8.00 PF 0.0 B26 30.0 0.0 13.5 0.0 2.5 120 FTG ---- FE 0.0 B27 30.0 0.0 13.5 0.0 0.006 TL 8.00 PV Pipe: 138 -83.8 2.635 PL 3.00 PF 0.4 B27 30.0 0.0 13.5 0.0 4.9 120 FTG T PE 0.0 38A 30.0 0.0 13.9 0.0 0.021 TL 19.47 PV Pipe: 138A 83.1 2.635 FL 9.00 PF 0.5 38A 30.0 0.0 13.9 0.0 4.9 120 FTG T FE 0.0 B28 30.0 0.0 13.4 0.0 0.020 TL 25.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 18 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 138B 41.4 2.635 PL 8.00 PF 0.0 B28 30.0 0.0 13.4 0.0 2.4 120 FTC ---- PE 0.0 B29 30.0 0.0 13.3 0.0 0.006 TL 8.00 PV Pipe: 139 -1092.7 6.357 PL 80.00 PF 3.8 1 28.0 0.0 25.9 0.0 11.0 120 FTC 3L PE 0.0 95 28.0 0.0 29.6 0.0 0.033 TL 113.95 PV Pipe: 140 -1092.7 8.249 PL 25.00 PF 1.1 95 28.0 0.0 29.6 0.0 6.6 120 FTG TBA PE 10.8 96 3.0 H.S. 41.6 100.0 0.009 TL 116.61 PV Pipe: 141 -1192.7 8.249 PL 2.00 PP 0.5 96 3.0 H.S. 41.6 100.0 7.2 120 FTG T PE 0.9 97 1.0 0.0 42.9 0.0 0.011 TL 43.11 PV Pipe: 305 -1192.7 8.510 PL 50.00 PF 0.6 97 1.0 0.0 42.9 0.0 6.7 140 FTG LG PE 1.7 98 -3.0 0.0 45.2 0.0 0.007 TL 80.91 PV Pipe: 306 FIXED PRESSURE LOSS DEVICE 99 -3.0 0.0 50.2 0.0 5.0 psi, 1192.7 gpm 98 -3.0 0.0 45.2 0.0 Pipe: 307 -1192.7 10.520 PL 425.00 PP 1.4 99 -3.0 0.0 50.2 0.0 4.4 140 FTG T2L PE 0.0 100 -3.0 H.S. 51.6 400.0 0.003 TL 563.25 PV Pipe: 308 -1592.7 10.520 PL 160.00 PF 1.0 100 -3.0 M.S. 51.6 400.0 5.9 140 FTG T PE 0.0 101 -3.0 0.0 52.6 0.0 0.004 TL 244.30 PV Pipe: 309 -1592.7 10.520 PL 288.00 PF 1.2 101 -3.0 0.0 52.6 0.0 5.9 140 FTG ---- PE 0.0 102 -3.0 SRCE 53.9 (N/A) 0.004 TL 288.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38050722 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 19 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.058 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 15.9 ft/sec at pipe 30. Available pressure at source node 102 under full flow conditions is 58.58 psi with a flow of 1663.72 gpm. PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 2.635 8.24 16.47 5.49 19.22 9.61 1.37 13.73 13.73 16.47 6.357 17.60 37.72 11.32 40.23 12.57 3.77 35.21 35.21 37.72 8.249 21.14 41.11 15.27 52.85 14.09 4.70 36.41 36.41 41.11 8.510 24.60 47.84 17.77 61.51 16.40 5.47 42.37 42.37 47.84 10.520 27.89 63.38 20.28 69.72 24.08 6.34 46.90 46.90 63.38 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv Tee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 Q LD lw ci) 4.) 0 z SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 20 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce O 0 0 o 0 • • • • 0 o 0 0 0 0 0 0 • H 00 N tO tn IV C") C') 0 I -QU)-r.4-.. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 21 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE 42/Produce WATER SUPPLY CURVE 72+ 66+ 60+ \ I 0\\ \ \ 54+ x \ I \\ I \ P48+ \ R I \\ E I \ S \ S 42+ \ U I <-40.0 psi @ 4060 gpm R I Flow Test Point E I 36+ P S I I 30+ ) I 24+ 18+ 12+ LEGEND I X = Required Water Supply 53.88 psi 8 1592.7 gpm " 6+ I 0 = Available Water Supply I 58.93 psi 8 1592.7 gpm +------+--------+--------+ ---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) LINDLEY FIRE PROTECTION CO. 1109 N. ARMANDO STREET ANAHEIM, CA 714-535-5761 LIC. # C161C34 NO. 1037930 HYDRAULIC CALCULATIONS FOR COSTCO #462 CARLSBAD 951 PALOMAR AIRPORT ROAD CARLSBAD, CA 92011 REMOTE AREA #3- MEAT DELI COOLER DATE: 05-31-2020 -DESIGN DATA- SYSTEM DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (INCLUDING HOSE) FLOW AND PRESSURE & BASE OF RISER: SPRINKLER ORIFICE SIZE: .43 GPM/SQ. FT. 2,000 S.F. 87.8 SQ. FT. 27 SPRINKLERS 1108.3 GPM 1608.3 GPM 1108.3 GPM @ 55.2 PSI 3/4" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/19/2018 C:\PROGRAM FILES\}JRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 102 63.0 40.0 4060.0 58.9 1608.3 55.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1608.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 500.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 1108.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) DP52 22.2 K=11.20 13.5 41.2 DP53 22.2 K=11.20 13.6 41.3 DP54 22.2 K=11.20 13.8 41.6 DP55 22.2 K=11.20 13.2 40.7 DP56 22.2 K=11.20 11.4 37.8 DP57 22.2 K=11.20 11.4 37.8 DP58 22.2 K=11.20 13.5 41.1 DP59 22.2 K11.20 13.6 41.3 DP60 22.2 K=11.20 13.7 41.5 DP61 22.2 K=11.20 13.6 41.4 0P62 22.2 K=11.20 13.7 41.4 DP63 22.2 K=11.20 13.9 41.8 DP64 22.2 K=11.20 13.5 41.2 DP65 22.2 K=11.20 13.6 41.3 DP66 22.2 K=11.20 13.7 41.5 DP67 22.5 K=11.20 13.5 41.1 DP68 22.5 K11.20 13.5 41.2 DP69 22.5 K11.20 13.8 41.7 DP70 22.5 K11.20 13.3 40.9 DP71 22.5 K=11.20 13.4 41.0 DP72 22.5 K=11.20 13.7 415 D273 22.5 K11.20 13.4 40.9 DP74 22.5 K=11.20 13.4 41.1 DP75 22.5 K=11.20 13.8 41.5 DP76 22.5 R=11.20 13.6 41.3 DP77 22.5 K=11.20 13.6 41.3 DP78 22.5 K=11.20 13.9 41.8 A52 30.5 - - - - 11.4 - - - A53 30.5 - - - - 11.5 A54 30.5 - - - - 11.7 - - - A55 30.5 - - - - 11.1 - - - 7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE 43/Meat-Deli Cooler NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) A56 30.5 - - - - 9.1 A57 30.5 - - - - 12.9 - - - A58 30.5 - - - - 11.4 - - - A59 30.5 - - - - 11.5 A60 30.5 - - - - 11.6 - - - A61 30.5 - - - - 11.5 - - - A62 30.5 - - - - 11.6 - - - A63 30.5 - - - - 11.8 A64 30.5 - - - - 11.4 A65 30.5 - - - - 11.5 - - - A66 30.5 - - - - 11.7 - - - A67 30.5 - - -'-11.5 - - - A68 30.5 - - - - 11.5 A69 30.5 - - - - 11.9 - - - A70 30.5 - - - - 11.3 - - - A71 30.5 - - - - ll. - - - A72 30.5 - - - - 11.7 - - - A73 30.5 - - - - 11.3 A74 30.5 - - - - 11.4 - - - A75 30.5 - - - - 11.8 - - - A76 30.5 - - - - 11.6 - - - A77 30.5 - - - - 11.6 - - - A78 30.5 - - - - 12.0 - - - B52 30.0 - - - - 12.7 B53 30.0 - - - - 12.7 - - - B54 30.0 - - - - 13.0 - - - B55 30.0 - - - - 12.3 - - - B56 30.0 - - - - 12.4 B57 30.0 - - - - 13.1 B58 30.0 - - - - 12.6 - - - B59 30.0 - - - - 12.6 - - - B60 30.0 - - - - 12.9 B61 30.0 - - - - 12.6 B62 30.0 - - - - 12.6 - - - B63 30.0 - - - - 12.9 - - - B64 30.0 - - - - 12.6 - - - B65 30.0 - - - - 12.6 B66 30.0 - - - - 12.9 B67 30.0 - - - - 12.5 - - - B68 30.0 - - - - 12.5 - - - B69 30.0 - - - - 12.9 - - - B70 30.0 - - - - 12.5 - - - B71 30.0 - - - - 12.5 - - - B72 30.0 - - - - 12.9 B73 30.0 - - - - 12.5 - - - B74 30.0 - - - - 12.6 - - - B75 30.0 - - - - 12.9 876 30.0 - - - - 12.6 B77 30.0 - - - - 12.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATED 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 1379 30.0 - - - - 13.0 1 28.0 - - - - 24.6 1A 30.0 - - - - 23.3 -- - 2 28.0 - - - - 15.5 2A 30.0 - - - - 15.1 - - - 3 28.0 - - - - 24.3 3A 30.0 - - - - 23.0 4 28.0 - - - - 15.6 - - - 4A 30.0 - - - - 15.1 - - - 5 28.0 - - - - 24.1 - - - 5A 30.0 - - - - 22.9 6 28.0 - - - - 15.6 - - - 6A 30.0 - - - - 15.2 - - - 7 28.0 - - - - 24.0 7A 30.0 - - - - 22.7 8 28.0 - - - - 15.6 - - - 8A 30.0 - - - - 15.2 9 28.0 - - - - 23.8 - - - 9A 30.0 -- - - 22.6 10 28.0 - - - - 15.6 10A 30.0 - - - - 15.2 - - - 11 28.0 - - - - 23.7 hA 30.0 - - - - 22.5 - - - 12 28.0 - - - - 15.7 - - - 12A 30.0 - - - - 15.2 13 28.0 - - - - 23.7 - - - 13A 30.0 - - - - 22.4 - - - 14 28.0 - - - - 15.7 14A 30.0 - - - - 15.2 - - - 15 28.0 - - - - 23.6 15A 30.0 - - - - 22.3 - - - 16 28.0 - - - - 15.7 16A 30.0 - - - - 15.2 - - - 17 28.0 - - - - 23.5 - - - 17A 30.0 - - - - 22.3 - - - 19 28.0 - - - - 15.6 - - - 18A 30.0 - - - - 15.2 - - - 19 28.0 - - - - 23.5 - - - 19A 30.0 - - - - 22.3 - - - 20 28.0 - - - - 15.6 20A 30.0 - - - - 15.1 - - - 21 28.0 - - - - 23.5 21A 30.0 - - - - 22.2 - - - 22 28.0 - - - - 15.6 - -- 22A 30.0 - - - - 15.1 23 28.0 - - - - 23.5 - - - 23A 30.0 - - - - 22.2 24 28.0 - - - - 15.6 24A 30.0 - - - - 15.1 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE 43/Meat-Deli Cooler NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 25 28.0 - - - - 23.5 25A 30.0 - - - - 22.2 26 28.0 - - - - 15.5 - - - 26A 30.0 - - - - 15.0 - - - 44 28.0 - - - - 14.8 - - - 44A 30.0 - - - - 13.1 - - - 45 28.0 - - - - 14.7 - - - 45A 30.0 - - - - 13.1 46 28.0 - - - - 14.7 - - - 46A 30.0 - - - - 13.0 - - - 47 28.0 - - - - 14.7 - - - 47A 30.0 - - - - 13.0 - - - 48 28.0 - - - - 14.7 48A 30.0 - - - - 13.0 - - - 49 28.0 - - - - 14.7 - - - 49A 30.0 - - - - 13.0 - - - 50 28.0 - - - - 14. - - - 50A 30.0 - - - - 13.0 - - - 51 28.0 - - - - 14.7 - - - 51A 30.0 - - - - 13.0 - - - 52 28.0 - - - - 14.8 52A 30.0 - - - - 13.1 - - - 95 28.0 - - - - 30.8 96 3.0 HOSE STREAM 42.7 100.0 97 1.0 - - - - 44.1 - - - 98 -3.0 - - - - 46.4 - - - 99 -3.0 - - - - 51.4 - - - 100 -3.0 HOSE STREAM 52.8 400.0 101 -3.0 - - - - 53.9 102 -3.0 SOURCE 55.2 1608.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -41.2 1.380 PL 8.25 PP 1.5 DP52 22.2 11.2 13.5 41.2 8.8 120 FTG E PE -3.6 A52 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 2 -41.3 1.380 PL 8.25 PF 1.5 DP53 22.2 11.2 13.6 41.3 8.9 120 FTG E PE -3.6 A53 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 3 -41.6 1.380 PL 8.25 PF 1.5 DP54 22.2 11.2 13.8 41.6 8.9 120 FTG E PE -3.6 A54 30.5 0.0 11.7 0.0 0.132 TL 11.25 PV Pipe: 4 -40.7 1.380 PL 8.25 PF 1.4 DP55 22.2 11.2 13.2 40.7 8.7 120 FTG E PE -3.6 A55 30.5 0.0 11.1 0.0 0.127 TL 11.25 PV Pipe: 5 -37.8 1.380 PL 8.25 PF 1.2 DP56 22.2 11.2 11.4 37.8 8.1 120 FTG E PE -3.6 A56 30.5 0.0 9.1 0.0 0.111 TL 11.25 PV Pipe: 6 -37.8 1.380 PL 8.25 PF 1.2 DP57 22.2 11.2 11.4 37.8 8.1 120 FTC E PE -3.6 A56 30.5 0.0 9.1 0.0 0.111 TL 11.25 PV Pipe: 7 -41.1 1.380 PL 8.25 PF 1.5 DP58 22.2 11.2 13.5 41.1 8.8 120 FTG E PE -3.6 A58 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 8 -41.3 1.380 PL 8.25 PP 1.5 DP59 22.2 11.2 13.6 41.3 8.9 120 FTG E PE -3.6 A59 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 9 -41.5 1.380 PL 8.25 PP 1.5 D?60 22.2 11.2 13.7 41.5 8.9 120 FTG E FE -3.6 A60 30.5 0.0 11.6 0.0 0.132 TL 11.25 PV Pipe: 10 -41.4 1.380 PL 8.25 PF 1.5 DP1 22.2 11.2 13.6 41.4 8.9 120 FTC E PE -3.6 A61 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 11 -41.4 1.380 FL 8.25 PF 1.5 DP62 22.2 11.2 13.7 41.4 8.9 120 FTG E PE -3.6 A62 30.5 0.0 11.6 0.0 0.132 TL 11.25 By Pipe: 12 -41.8 1.380 FL 8.25 PP 1.5 DP63 22.2 11.2 13.9 41.8 9.0 120 FTC 2 PE -3. A63 30.5 0.0 11.6 0.0 0.134 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE 43/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -41.2 1.380 FL 8.25 PF 1.5 DP64 22.2 11.2 13.5 41.2 8.8 120 FTG E FE -3.6 A64 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 14 -41.3 1.380 FL 8.25 PF 1.5 DP65 22.2 11.2 13.6 41.3 8.9 120 FTG E FE -3.6 A65 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 15 -41.5 1.380 PL 8.25 PF 1.5 DP66 22.2 11.2 13.7 41.5 8.9 120 FTG E FE -3.6 A66 30.5 0.0 11.7 0.0 0.132 TL 11.25 PV Pipe: 16 -41.1 1.380 FL 8.25 PF 1.5 DP67 22.5 11.2 13.5 41.1 8.8 120 FTG E PE -3.5 A67 30.5 0.0 11.5 0.0 0.130 TL 11.25 PV Pipe: 17 -41.2 1.380 PL 8.25 PF 1.5 DP68 22.5 11.2 13.5 41.2 8.8 120 FTG E FE -3.5 A68 30.5 0.0 11.5 0.0 0.130 TL 11.25 PV Pipe: 18 -41.7 1.380 FL 8.25 PF 1.5 DP69 22.5 11.2 13.8 41.7 8.9 120 FTG E PE -3.5 A69 30.5 0.0 11.9 0.0 0.133 TL 11.25 PV Pipe: 19 -40.9 1.380 FL 8.25 PF 1.4 DF70 22.5 11.2 13.3 40.9 8.8 120 FTG E FE -3.5 A70 30.5 0.0 11.3 0.0 0.129 TL 11.25 PV Pipe: 20 -41.0 1.380 PL 8.25 PF 1.5 DP71 22.5 11.2 13.4 41.0 8.8 120 FTG E FE -3.5 A71 30.5 0.0 11.4 0.0 0.129 TL 11.25 PV Pipe: 21 -41.5 1.380 FL 8.25 PF 1.5 DP72 22.5 11.2 13.7 41.5 8.9 120 FTG E FE -3.5 A72 30.5 0.0 11.7 0.0 0.132 TL 11.25 PV ?ipe: ZZ -40.9 1.360 FL 8.25 PF 1.4 DP73 22.5 11.2 13.4 40.9 8.8 120 FTG E FE -3.5 A73 30.5 0.0 11.3 0.0 0.129 TL 11.25 PV Pipe: 23 -41.1 1.380 FL 8.25 PF 1.5 DP74 22.5 11.2 13.4 41.1 8.8 120 FTG E FE -3.5 A74 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 24 -41.5 1.380 PL 8.25 PP 1.5 DP75 22.5 11.2 13.8 41.5 8.9 120 FTG E FE -3.5 A75 30.5 0.0 11.8 0.0 0.132 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\F1A5S88\#006 3.SDF JOB TITLE: #462 COSTCO CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FFS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 -41.3 1.380 FL 8.25 PF 1.5 DP76 22.5 11.2 13.6 41.3 8.9 1.20 FTG E FE -3.5 A76 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 25A -41.3 1.380 FL 8.25 PF 1.5 DP77 22.5 11.2 13.6 41.3 8.9 120 FTG E FE -3.5 Al? 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 25B -41.8 1.380 FL 8.25 PF 1.5 DP78 22.5 11.2 13.9 41.8 9.0 120 FTG E FE -3.5 A78 30.5 0.0 12.0 0.0 0.134 TL 11.25 PV Pipe: 26 -41.2 1.610 FL 5.50 PP 1.1 A52 30.5 0.0 11.4 0.0 6.5 120 FTG ET FE 0.2 B52 30.0 0.0 12.7 0.0 0.061 TL 17.50 PV Pipe: 27 -41.3 1.610 FL 4.50 PF 1.0 A53 30.5 0.0 11.5 0.0 6.5 120 FTC ET PE 0.2 B53 30.0 0.0 12.7 0.0 0.062 TL 16.50 PV Pipe: 28 -41.6 1.610 FL 5.50 PP 1.1 A54 30.5 0.0 11.7 0.0 6.6 120 FTG ET FE 0.2 B54 30.0 0.0 13.0 0.0 0.063 TL 17.50 PV Pipe: 29 -40.7 1.610 FL 5.50 PP 1.1 A55 30.5 0.0 11.1 0.0 6.4 120 FTC ET PE 0.2 B55 30.0 0.0 12.3 0.0 0.060 TL 17.50 PV Pipe: 30 -75.6 1.610 PL 4.50 PF 3.1 A56 30.5 0.0 9.1 0.0 11.9 120 FTG ET FE 0.2 B56 30.0 0.0 12.4 0.0 0.189 TL 16.50 PV Pipe: 31 0.0 1.610 FL 6.00 PP 0.0 A57 30.5 0.0 12.9 0.0 0.0 120 FTG ET FE 0.2 B57 30.0 00 13.1 0.0 0.000 TL 18.00 PV Pipe: 32 -41.1 1.610 FL 4.00 PF 1.0 A58 30.5 0.0 11.4 0.0 6.5 120 FTG ET FE 0.2 B58 30.0 0.0 12.6 0.0 0.061 TL 1600 PV Pipe: 33 -41.3 1.610 PL 3.00 PF 0.9 A59 30.5 0.0 11.5 0.0 6.5 120 FTG ET FE 0.2 859 30.0 0.0 12.6 0.0 0.062 TL 15.00 PV Pipe: 34 -41.5 1.610 FL 5.00 PF 1.1 A60 30.5 0.0 11.6 0.0 6.5 120 FTC ET PE 0.2 B60 30.0 0.0 12.9 0.0 0.062 TL 17.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10119/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\4006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 35 -41.4 1.610 FL 1.00 PF 0.8 A61 30.5 0.0 11.5 0.0 6.5 120 FTG ET PE 0.2 B61 30.0 0.0 12.6 0.0 0.062 TL 13.00 PV Pipe: 36 -41.4 1.610 FL 1.00 PF 0.8 A62 30.5 0.0 11.6 0.0 6.5 120 FTG ET PE 0.2 862 30.0 0.0 12.6 0.0 0.062 TL 13.00 PV Pipe: 37 -41.8 1.610 FL 1.00 PF 0.8 A63 30.5 0.0 11.8 0.0 6.6 120 FTG ET PE 0.2 B63 30.0 0.0 12.9 0.0 0.063 TL 13.00 PV Pipe: 38 -41.2 1.610 FL 3.50 PF 1.0 A64 30.5 0.0 11.4 0.0 6.5 120 FTG ET FE 0.2 B64 30.0 0.0 12.6 0.0 0.061 TL 15.50 PV Pipe: 39 -41.3 1.610 FL 2.50 PP 0.9 A65 30.5 0.0 11.5 0.0 6.5 120 FTC ET PE 0.2 865 30.0 0.0 12.6 0.0 0.062 TL 14.50 PV Pipe: 40 -41.5 1.610 FL 4.50 PF 1.0 A66 30.5 0.0 11.7 0.0 6.5 120 FTG ET FE 0.2 B66 30.0 0.0 12.9 0.0 0.062 TL 16.50 PV Pipe: 41 -41.1 1.610 FL 1.00 PF 0.8 A67 30.5 0.0 11.5 0.0 6.5 120 FTG ET FE 0.2 B67 30.0 0.0 12.5 0.0 0.061 TL 13.00 PV Pipe: 42 -41.2 1.610 FL 1.00 PF 0.8 A68 30.5 0.0 11.5 0.0 6.5 120 FTG ET FE 0.2 B68 30.0 0.0 12.5 0.0 0.061 TL 13.00 PV Pipe: 43 -41.7 1.610 PL 1.00 PF 0.8 A69 30.5 0.0 11.9 0.0 6.6 120 FTG ET FE 0.2 B69 30.0 0.0 12.9 0.0 0.063 TL 13.00 PV Pipe: 44 -40.9 1.610 FL. 4.00 PF 1.0 A70 30.5 0.0 11.3 0.0 6.4 120 FTG ET FE 0.2 30.0 0.0 12.5 0.0 0.061 TL 16.00 PV Pipe: 45 -41.0 1.610 FL 3.00 PF 0.9 A71 30.5 0.0 11.4 0.0 6.5 120 FTC ET PE 0.2 871 30.0 0.0 12.5 0.0 0.061 TL 15.00 PV Pipe: 46 -41.5 1.610 FL 3.50 PF 1.0 A72 30.5 0.0 11.7 0.0 6.5 120 FTG ET FE 0.2 B72 30.0 0.0 12.9 0.0 0.062 TL 15.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 47 -40.9 1.610 FL 4.00 FE 1.0 A73 30.5 0.0 11.3 0.0 6.5 120 FTC ET PE 0.2 B73 30.0 0.0 12.5 0.0 0.061 TL 16.00 PV Pipe: 48 -41.1 1.610 FL 3.00 PF 0.9 A74 30.5 0.0 11.4 0.0 6.5 120 FTG ET FE 0.2 B74 30.0 0.0 12.6 0.0 0.061 TL 15.00 PV Pipe: 49 -41.5 1.610 FL 3.00 PF 0.9 A75 30.5 0.0 11.8 0.0 6.5 120 FTG ET FE 0.2 875 30.0 0.0 12.9 0.0 0.062 TL 15.00 PV Pipe: 50 -41.3 1.610 PL 1.00 PF 0.8 A76 30.5 0.0 11.6 0.0 6.5 120 FTG ET Pt 0.2 B76 30.0 0.0 12.6 0.0 0.062 TL 13.00 PV Pipe: 50A -41.3 1.610 FL 1.00 PP 0.8 A77 30.5 0.0 11.6 0.0 6.5 120 FTG ET PE 0.2 B77 30.0 0.0 12.7 0.0 0.062 TL 13.00 PV Pipe: 50B -41.8 1.610 FL 1.00 PF 0.8 A78 30.5 0.0 12.0 0.0 6.6 120 FTG ET PE 0.2 B78 30.0 0.0 13.0 0.0 0.063 TL 13.00 PV Pipe: 51 90.0 2.635 FL 2.00 PP 0.4 1 28.0 0.0 24.6 0.0 5.3 120 FTG T FE -0.9 1A 30.0 0.0 23.3 0.0 0.024 TL 18.47 PV Pipe: 52 -90.0 2.635 FL 2.00 PF 0.4 2 28.0 0.0 15.5 0.0 5.3 120 FTG T FE -0.9 2A 30.0 0.0 15.1 0.0 0.024 TL 18.47 PV Pipe: 53 88.4 2.635 PL 2.00 PP 0.4 3 28.0 0.0 24.3 0.0 5.2 120 FTG T FE -0.9 3A 30.0 0.0 23.0 0.0 0.023 TL 18.47 PV Pipe: 54 -88.4 2.635 FL 2.00 PF 0.4 4 28.0 0.0 15.6 0.0 5.2 120 FTG T FE -0.9 4A 30.0 0.0 15.1 0.0 0.023 TL 18.47 PV Pipe: 55 87.1 2.635 FL 2.00 PF 0.4 5 28.0 0.0 24.1 0.0 5.1 120 FTC T FE -0.9 5A 30.0 0.0 22.9 0.0 0.022 TL 18.47 PV Pipe: 56 -87.1 2.635 FL 2.00 PF 0.4 6 28.0 0.0 15.6 0.0 5.1 120 FTG T FE -0.9 6A 30.0 0.0 15.2 0.0 0.022 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASSB8\4t006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) NW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 57 86.1 2.635 FL 2.00 PF 0.4 7 28.0 0.0 24.0 0.0 5.1 120 FTG T PE -0.9 7A 30.0 0.0 22.7 0.0 0.022 TL 18.47 PV Pipe: 58 -86.1 2.635 FL 2.00 PF 0.4 8 28.0 0.0 15.6 .0.0 5.1 120 FTC T PE -0.9 BA 30.0 0.0 15.2 0.0 0.022 TL 18.47 PV Pipe: 59 85.3 2.635 PL 2.00 PF 0.4 9 28.0 0.0 23.8 0.0 5.0 120 FTG T FE -0.9 9A 30.0 0.0 22.6 0.0 0.021 TL 18.47 PV Pipe: 60 -85.3 2.635 FL 2.00 PF 0.4 10 28.0 0.0 15.6 0.0 5.0 120 FTG T PE -0.9 10A 30.0 0.0 15.2 0.0 0.021 TL 18.47 PV Pipe: 61 84.7 2.635 PL 2.00 PF 0.4 11 28.0 0.0 23.7 0.0 5.0 120 FTG T FE -0.9 hA 30.0 0.0 22.5 0.0 0.021 TL 18.47 PV Pipe: 62 -84.7 2.635 PL 2.00 PF 0.4 12 28.0 0.0 15.7 0.0 5.0 120 FTG T PE -0.9 12A 30.0 0.0 15.2 0.0 0.021 TL 18.47 PV Pipe: 63 84.2 2.635 PL 2.00 PF 0.4 13 28.0 0.0 23.7 0.0 5.0 120 FTG T PE -0.9 13A 30.0 0.0 22.4 0.0 0.021 TL 18.47 PV Pipe: 64 -84.2 2.635 FL 2.00 PF 0.4 14 28.0 0.0 15.7 0.0 5.0 120 FTC T FE -0.9 14A 30.0 0.0 15.2 0.0 0.021 TL 18.47 PV Pipe: 65 83.8 2.635 PL 2.00 PF 0.4 15 28.0 0.0 23.6 0.0 4.9 120 FTG T FE -0.9 iSA 30.0 0.0 22.3 0.0 0.021 TL 18.47 PV Pipe: 66 -83.8 2.635 PL 2.00 PF 0.4 16 28.0 0.0 15.7 0.0 4.9 120 FTC T PE -0.9 16A 30.0 0.0 15.2 0.0 0.021 TL 18.47 PV Pipe: 67 83.6 2.635 PL 2.00 PF 0.4 17 28.0 0.0 23.5 0.0 4.9 120 FTG T FE -0.9 hA 30.0 0.0 22.3 0.0 0.021 TL 18.47 PV Pipe: 68 -83.6 2.635 PL 2.00 PF 0.4 lB 28.0 0.0 15.6 0.0 4.9 120 FTG T FE -0.9 18A 30.0 0.0 15.2 0.0 0.021 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 69 83.5 2.635 PL 2.00 PF 0.4 19 28.0 0.0 23.5 0.0 4.9 120 FTG T PE -0.9 19A 30.0 0.0 22.3 0.0 0.021 TL 18.47 PV Pipe: 70 -83.5 2.635 FL 2.00 PF 0.4 20 28.0 0.0 15.6 0.0 4.9 120 FTG T PE -0.9 20A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe; 71 83.6 2.635 PL 2.00 PF 0.4 21 28.0 0.0 23.5 0.0 4.9 120 FTG T FE -0.9 21A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe; 72 -83.6 2.635 PL 2.00 PF 0.4 22 28.0 0.0 15.6 0.0 4.9 120 FTG T PE -0.9 22A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe: 73 83.7 2.635 PL 2.00 PF 0.4 23 28.0 0.0 23.5 0.0 4.9 120 FTG T FE -0.9 23A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe: 74 -83.7 2.635 FL 2.00 PF 0.4 24 28.0 0.0 15.6 0.0 4.9 120 FTG T FE -0.9 24A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe: 75 84.0 2.635 PL 2.00 PF 0.4 25 28.0 0.0 23.5 0.0 4.9 120 FTG T FE -0.9 25A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe: 76 -84.0 2.635 FL 2.00 PF 0.4 26 28.0 0.0 15.5 0.0 4.9 120 FTG T FE -0.9 26A 30.0 0.0 15.0 0.0 0.021 TL 18.47 PV Pipe: 76A 124.0 2.635 PL 2.00 PF 0.8 44 28.0 0.0 14.8 0.0 7.3 120 FTG T PE -0.9 44A 30.0 0.0 13.1 0.0 0.043 TL 18.47 PV Pipe: 76B 116.3 2.635 PL 2.00 PF 0.7 45 28.0 0.0 14.7 0.0 6.8 120 FTG T PE -0.9 45A 30.0 0.0 13.1 0.0 0.038 TL 18.47 PV Pipe: 76C 123.9 2.635 FL 2.00 PF 0.8 46 28.0 0.0 14.7 0.0 7.3 120 FTG T FE -0.9 46A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 76D 124.6 2.635 FL 2.00 PF 0.8 47 28.0 0.0 14.7 0.0 7.3 120 FTG T FE -0.9 47A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 10/19/2018 C:\PROGRAM FILES\}IRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 76E 124.0 2.635 PL 2.00 PF 0.8 48 28.0 0.0 14.7 0.0 7.3 120 FTG T PE -0.9 48A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 76F 124.0 2.635 PL 2.00 PF 0.8 49 28.0 0.0 14.7 0.0 73 120 FTG T PE -0.9 49A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 76G 123.4 2.635 PL 2.00 PF 0.8 50 28.0 0.0 14.7 0.0 7.3 120 FTG T PS -0.9 50A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 765 123.6 2.635 FL 2.00 PP 0.8 51 28.0 0.0 14.7 0.0 7.3 120 FTG T PE -0.9 51A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 761 124.5 2.635 PL 2.00 PF 0.8 52 28.0 0.0 14.8 0.0 7.3 120 FTG T PE -0.9 52A 30.0 0.0 13.1 0.0 0.043 TL 18.47 PV Pipe: 77 -465.0 6.357 PL 8.00 PF 0.1 2 28.0 0.0 15.5 0.0 4.7 120 FTG ---- FE 0.0 4 28.0 0.0 15.6 0.0 0.007 TL 8.00 PV Pipe: 78 -376.6 6.357 PL 8.00 PF 0.0 4 28.0 0.0 15.6 0.0 3.8 120 FTG ---- PE 0.0 6 28.0 0.0 15.6 0.0 0.005 TL 8.00 PV Pipe: 79 -289.4 6.357 FL 8.00 PP 0.0 6 28.0 0.0 15.6 0.0 2.9 120 FTG ---- PS 0.0 8 28.0 0.0 15.6 0.0 0.003 TL 8.00 PV Pipe: 80 -203.3 6.357 FL 8.00 PF 0.0 8 28.0 0.0 15.6 0.0 2.1 120 FTG ---- PE 0.0 10 28.0 0.0 15.6 0.0 0.001 TL 8.00 PV Pipe: 81 -118.0 6.357 PL 6.00 PF 0.0 10 28.0 0.0 15.6 0.0 1.2 120 FTG ---- PE 0.0 12 28.0 0.0 15.7 0.0 0.001 TL 8.00 PV Pipe: 82 -33.3 6.357 FL 8.00 PP 0.0 12 28.0 0.0 15.7 0.0 0.3 120 FTG ---- FE 0.0 14 28.0 0.0 15.7 0.0 0.000 TL 8.00 PV Pipe: 83 50.9 6.357 FL 8.00 PE 0.0 14 28.0 0.0 15.7 0.0 0.5 120 FTG ---- FE 0.0 16 28.0 0.0 15.7 0.0 0.000 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 84 134.7 6.357 FL 8.00 PF 0.0 16 28.0 0.0 15.7 0.0 1.4 120 FTG ---- FE 0.0 18 28.0 0.0 15.6 0.0 0.001 TL 8.00 PV Pipe: 85 218.4 6.357 PL 8.00 PF 0.0 18 28.0 0.0 15.6 0.0 2.2 120 FTG ---- FE 0.0 20 28.0 0.0 15.6 0.0 0.002 TL 8.00 PV Pipe: 86 301.9 6.357 PL 8.00 PF 0.0 20 28.0 0.0 15.6 0.0 3.1 120 FTG ---- FE 0.0 22 28.0 0.0 15.6 0.0 0.003 TL 8.00 PV Pipe: 87 385.5 6.357 FL 8.00 PF 0.0 22 28.0 0.0 15.6 0.0 3.9 120 FTG ---- PE 0.0 24 28.0 0.0 15.6 0.0 0.005 TL 8.00 PV Pipe: 88 469.2 6.357 PL 8.00 PP 0.1 24 28.0 0.0 15.6 0.0 4.7 120 FTG ---- FE 0.0 26 28.0 0.0 15.5 0.0 0.007 TL 8.00 PV Pipe: 89 1018.2 6.357 FL 8.00 PP 0.2 1 28.0 0.0 24.6 0.0 10.3 120 FTG ---- FE 0.0 3 28.0 0.0 24.3 0.0 0.029 TL 8.00 PV Pipe: 90 929.8 6.357 FL 8.00 PF 0.2 3 28.0 0.0 24.3 0.0 9.4 120 FTG ---- PE 0.0 5 28.0 0.0 24.1 0.0 0.024 TL 8.00 PV Pipe: 91 842.7 6.357 FL 8.00 PF 0.2 5 28.0 0.0 24.1 0.0 8.5 120 FTG ---- FE 0.0 7 28.0 0.0 24.0 0.0 0.020 TL 8.00 PV Pipe: 92 756.6 6.357 FL 8.00 PP 0.1 7 28.0 0.0 24.0 0.0 7.6 120 FTG ---- FE 0.0 9 28.0 0.0 23.8 0.0 0.017 TL 8.00 PV Pipe: 93 671.3 6.357 FL 8.00 PP 0.1 9 28.0 0.0 23.8 0.0 6.8 120 FTG ---- FE 0.0 11 28.0 0.0 23.7 0.0 0013 TL 9-00 PV Pipe: 94 586.6 6.357 FL 8.00 PF 0.1 11 28.0 0.0 23.7 0.0 5.9 120 FTG ---- FE 0.0 13 28.0 0.0 23.7 0.0 0.010 TL 8.00 PV Pipe: 95 502.4 6.357 FL 8.00 PP 0.1 13 28.0 0.0 23.7 0.0 5.1 120 FTG ---- PE 0.0 15 28.0 0.0 23.6 0.0 0.008 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 96 418.5 6.351 PL 9.00 PP 0.0 15 28.0 0.0 23.6 0.0 4.2 120 FTG ---- FE 0.0 17 28.0 0.0 23.5 0.0 0.006 TL 8.00 PV Pipe: 97 334.9 6.357 PL 8.00 PP 0.0 17 28.0 0.0 23.5 0.0 3.4 120 FTG ---- PE 0.0 19 28.0 0.0 23.5 0.0 0.004 TL 8.00 PV Pipe: 98 251.4 6.357 PL 8.00 PF 0.0 19 28.0 0.0 23.5 0.0 2.5 120 FTG ---- FE 0.0 21 28.0 0.0 23.5 0.0 0.002 TL 8.00 PV Pipe: 99 161.8 6.357 FL 8.00 PF 0.0 21 28.0 0.0 23.5 0.0 1.7 120 FTG ---- PE 0.0 23 28.0 0.0 23.5 0.0 0.001 TL 8.00 PV Pipe: 100 84.0 6.357 PL 8.00 FE 0.0 23 28.0 0.0 23.5 0.0 0.8 120 FTG ---- PE 0.0 25 28.0 0.0 23.5 0.0 0.000 TL 8.00 PV Pipe: 101 430.9 6.357 FL 16.00 PP 0.1 44 28.0 0.0 14.8 0.0 4.4 120 FTG ---- FE 0.0 45 28.0 0.0 14.7 0.0 0.006 TL 16.00 PV Pipe: 102 314.7 6.357 FL 8.00 PP 0.0 45 28.0 0.0 14.7 0.0 3.2 120 FTG ---- PE 0.0 46 28.0 0.0 14.7 0.0 0.003 TL 8.00 PV Pipe: 103 190.7 6.357 PL 8.00 PF 0.0 46 28.0 0.0 14.7 0.0 1.9 120 FTG ---- FE 0.0 47 28.0 0.0 14.7 0.0 0.001 TL 8.00 PV Pipe: 104 66.2 6.357 PL 8.00 PF 0.0 47 28.0 0.0 14.7 0.0 0.7 120 FTG ---- PE 0.0 48 28.0 0.0 14.7 0.0 0.000 TL 8.00 PV Pipe: 105 -37.6 0.357 FL 6.00 FF 0.0 48 28.0 0.0 14.7 0.0 0.6 120 FTG ---- FE 0.0 49 28.0 0.0 14.7 0.0 0.000 TL 8.00 PV Pipe: 106 -181.8 6.357 PL 8.00 PF 0.0 49 28.0 0.0 14.7 0.0 1.8 120 FTG ---- FE 0.0 50 28.0 0.0 14.7 0.0 0.001 TL 8.00 PV Pipe: 107 -305.2 6.357 PL 8.00 PF 0.0 50 28.0 0.0 14.7 0.0 3.1 120 FTG ---- PE 0.0 51 28.0 0.0 14.7 0.0 0.003 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 15 DATE: 10/19/2018 C:\PROGP.AM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: 0462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 108 -428.8 6.357 PL 16.00 PF 0.1 51 28.0 0.0 14.7 0.0 4.3 120 FTG ---- FE 0.0 52 28.0 0.0 14.8 0.0 0.006 TL 16.00 PV Pipe: 120 -553.3 6.357 PL 55.00 PF 0.7 52 28.0 0.0 14.8 0.0 5.6 120 FTG 2L FE 0.0 26 28.0 0.0 15.5 0.0 0.009 TL 77.63 PV Pipe: 121 -555.0 6.357 PL 55.00 PP 0.7 44 28.0 0.0 14.8 0.0 5.6 120 FTG 2L PE 0.0 2 28.0 0.0 15.5 0.0 0.009 TL 77.63 PV Pipe: 122 90.0 2.635 PL 312.00 PP 8.2 1A 30.0 0.0 23.3 0.0 5.3 120 FTG 2T PE 0.0 2A 30.0 0.0 15.1 0.0 0.024 TL 344.95 PV Pipe: 123 88.4 2.635 PL 312.00 PP 7.9 3A 30.0 0.0 23.0 0.0 5.2 120 FTG 2T PE 0.0 4A 30.0 0.0 15.1 0.0 0.023 TL 344.95 PV Pipe: 124 87.1 2.635 PL 312.00 PP 7.7 5A 30.0 0.0 22.9 0.0 5.1 120 FTG 2T PE 0.0 6A 30.0 0.0 15.2 0.0 0.022 TL 344.95 PV Pipe: 125 86.1 2.635 FL 312.00 PF 7.5 7A 30.0 0.0 22.7 0.0 5.1 120 FTG 2T PE 0.0 8A 30.0 0.0 15.2 0.0 0.022 TL 344.95 PV Pipe: 126 85.3 2.635 PL 312.00 PF 7.4 9A 30.0 0.0 22.6 0.0 5.0 120 FTG 2T PE 0.0 10A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 127 84.7 2.635 PL 312.00 PP 7.3 hA 30.0 0.0 22.5 0.0 5.0 120 FTG 2T PE 0.0 12A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 128 84.2 2.635 PL 312.00 PF 7.2 13A 30.0 0.0 22.4 0.0 5.0 120 FTG 2T FE 0.0 14A 30.0 0.0 152 OO 0021 TL 344.95 PV Pipe: 129 83.8 2.635 FL 312.00 PP 7.2 15A 30.0 0.0 22.3 0.0 4.9 120 FTG 2T FE 0.0 16A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 130 83.6 2.635 PL 312.00 PP 7.1 17A 30.0 0.0 22.3 0.0 4.9 120 FTG 2T PE 0.0 iRA 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 16 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 131 83.5 2.635 PL 312.00 PP 7.1 19A 30.0 0.0 22.3 0.0 4.9 120 FTG 2T PE 0.0 20A 30.0 0.0 15.1 0.0 0.021 TL 344.95 PV Pipe: 132 83.6 2.635 PL 312.00 PP 7.1 21A 30.0 0.0 22.2 0.0 4.9 120 FTG 2T FE 0.0 22A 30.0 0.0 15.1 0.0 0.021 TL 344.95 PV Pipe: 133 83.7 2.635 PL 312.00 PF 7.2 23A 30.0 0.0 22.2 0.0 4.9 120 FTG 2T PE 0.0 24A 30.0 0.0 15.1 0.0 0.021 TL 344.95 PV Pipe: 134 84.0 2.635 PL 312.00 PF 7.2 25A 30.0 0.0 22.2 0.0 4.9 120 FTG 2T FE 0.0 26A 30.0 0.0 15.0 0.0 0.021 TL 344.95 PV Pipe: 135 -41.2 2.635 PL 7.00 PP 0.0 B52 30.0 0.0 12.7 0.0 2.4 120 FTG ---- PE 0.0 353 30.0 0.0 12.7 0.0 0.006 TL 7.00 PV Pipe: 136 -82.5 2.635 FL 3.50 PE 0.4 B53 30.0 0.0 12.7 0.0 4.9 120 FTG T FE 0.0 44A 30.0 0.0 13.1 0.0 0.020 TL 19.97 PV Pipe: 137 41.6 2.635 FL 6.00 PF 0.1 44A 30.0 0.0 13.1 0.0 2.4 120 FTG T PE 0.0 354 30.0 0.0 13.0 0.0 0.006 TL 22.47 PV Pipe: 138 -40.7 2.635 FL 7.00 PP 0.0 855 30.0 0.0 12.3 0.0 2.4 120 FTG ---- PE 0.0 356 30.0 0.0 12.4 0.0 0.005 TL 7.00 PV Pipe: 139 -116.3 2.635 FL 3.00 PF 0.7 B56 30.0 0.0 12.4 0.0 6.8 120 FTG T FE 0.0 45A 30.0 0.0 13.1 0.0 0.038 TL 19.47 PV Pipe: 140 0.0 2.635 PL 1.00 PF 0.0 45A 30.0 0.0 13.1 0.0 0.0 120 FTG T FE 0.0 B57 30.0 0.0 13.1 0.0 0.000 TL 17.47 PV Pipe: 141 -41.1 2.635 PL 7.00 PF 0.0 B58 30.0 0.0 12.6 0.0 2.4 120 FTG ---- PE 0.0 359 30.0 0.0 12.6 0.0 0.006 TL 7.00 ?V Pipe: 142 -82.4 2.635 PL 3.00 PF 0.4 859 30.0 0.0 12.6 0.0 4.8 120 FTG T FE 0.0 46A 30.0 0.0 13.0 0.0 0.020 TL 19.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 17 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 143 41.5 2.635 PL 1.00 PF 0.1 46A 30.0 0.0 13.0 0.0 2.4 120 FTG T PE 0.0 B60 30.0 0.0 12.9 0.0 0.006 TL 17.47 PV Pipe: 144 -41.4 2.635 FL 10.00 PF 0.1 861 30.0 0.0 12.6 0.0 2.4 120 FTG ---- PE 0.0 B62 30.0 0.0 12.6 0.0 0.006 TL 10.00 PV Pipe: 145 -82.8 2.635 PL 2.00 PF 0.4 862 30.0 0.0 12.6 0.0 4.9 120 FTC T PE 0.0 47A 30.0 0.0 13.0 0.0 0.020 TL 18.47 PV Pipe: 146 41.8 2.635 PL 4.00 PF 0.1 47A 30.0 0.0 13.0 0.0 2.5 120 FTG T PE 0.0 863 30.0 0.0 12.9 0.0 0.006 TL 20.47 PV Pipe: 147 -41.2 2.635 FL 7.00 PF 0.0 B64 30.0 0.0 12.6 0.0 2.4 120 FTC ---- FE 0.0 B65 30.0 0.0 12.6 0.0 0.006 TL 7.00 PV Pipe: 148 -82.5 2.635 PL 3.00 PF 0.4 865 30.0 0.0 12.6 0.0 4.9 120 FTC T FE 0.0 48A 30.0 0.0 13.0 0.0 0.020 TL 19.47 PV Pipe: 149 41.5 2.635 PL 1.00 PF 0.1 48A 30.0 0.0 13.0 0.0 2.4 120 FTG T PR 0.0 866 30.0 0.0 12.9 0.0 0.006 TL 17.47 PV Pipe: 150 -41.1 2.635 PL 7.00 PF 0.0 B67 30.0 0.0 12.5 0.0 2.4 120 FTG ---- PR 0.0 B68 30.0 0.0 12.5 0.0 0.006 TL 7.00 PV Pipe: 151 -82.3 2.635 PL 6.50 PF 0.5 B68 30.0 0.0 12.5 0.0 4.8 120 FTG T PR 0.0 49A 30.0 0.0 13.0 0.0 0.020 TL 22.97 PV Pipe: 152 41.7 2.635 FL 1.00 PF 0.1 49A 30.0 0.0 13.0 0.0 2.5 120 FTG T FE 0.0 B69 30.0 0.0 12.9 0.0 0006 TL 17.47 PV Pipe: 153 -40.9 2.635 PL 8.00 PF 0.0 B70 30.0 0.0 12.5 0.0 2.4 120 FTC ---- PR 0.0 B71 30.0 0.0 12.5 0.0 0.006 TL 8.00 PV Pipe: 154 -81.9 2.635 FL 7.00 PF 0.5 871 30.0 0.0 12.5 0.0 4.8 120 FTC T FE 0.0 50A 30.0 0.0 13.0 0.0 0.020 TL 23.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 18 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 155 41.5 2.635 PL 2.00 PF 0.1 50A 30.0 0.0 13.0 0.0 2.4 120 FTG T PE 0.0 B72 30.0 0.0 12.9 0.0 0.006 TL 18.47 PV Pipe: 156 -40.9 2.635 FL 8.00 Pr 0.0 B73 30.0 0.0 12.5 0.0 2.4 120 FTC ---- PE 0.0 B74 30.0 0.0 12.6 0.0 0.006 TL 8.00 PV Pipe: 157 -82.0 2.635 PL 7.00 PP 0.5 574 30.0 0.0 12.6 0.0 4.8 120 FTG T PE 0.0 51A 30.0 0.0 13.0 0.0 0.020 TL 23.47 PV Pipe: 158 41.5 2.635 PL 2.00 PP 0.1 51A 30.0 0.0 13.0 0.0 2.4 120 FTG T PE 0.0 B75 30.0 0.0 12.9 0.0 0.006 TL 18.47 PV Pipe: 159 -41.3 2.635 PL 7.00 PF 0.0 B76 30.0 0.0 12.6 0.0 2.4 120 FTG ---- FE 0.0 B77 30.0 0.0 12.7 0.0 0.006 TL 7.00 PV Pipe: 160 -82.6 2.635 PL 6.50 PF 0.5 B77 30.0 0.0 12.7 0.0 4.9 120 FTG T FE 0.0 52A 30.0 0.0 13.1 0.0 0.020 TL 22.97 PV Pipe: 161 41.8 2.635 FL 1.00 PF 0.1 52A 30.0 0.0 13.1 0.0 2.5 120 FTG T FE 0.0 B78 30.0 0.0 13.0 0.0 0.006 TL 17.47 PV Pipe: 302 -1108.2 6.357 PL 150.00 PF 6.2 1 28.0 0.0 24.6 0.0 11.2 120 FTG 3L FE 0.0 95 28.0 0.0 30.8 0.0 0.034 TL 183.95 PV Pipe: 303 -1108.2 8.249 FL 25.00 PP 1.1 95 28.0 0.0 30.8 0.0 6.7 120 FTG TBA FE 10.8 96 3.0 H.S. 42.7 100.0 0.010 TL 116.61 PV Pipe: 304 -1208.2 8.249 PL 2.00 PP 0.5 96 3.0 H.S. 42.7 100.0 7.3 120 FTG T PE 0.9 97 1.0 0.0 44.1 0.0 0.011 TL 43.11 PV Pipe: 305 -1208.2 8.510 PL 50.00 PF 0.6 97 1.0 0.0 44.1 0.0 6.8 140 FTC LC PE 1.7 98 -3.0 0.0 46.4 0.0 0.007 TL 80.91 PV Pipe: 306 FIXED PRESSURE LOSS DEVICE 99 -3.0 0.0 51.4 0.0 5.0 psi, 1208.2 gpm 98 -3.0 0.0 46.4 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 19 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\}1ASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 307 -1208.2 10.520 FL 425.00 PF 1.4 99 -3.0 0.0 51.4 0.0 4.5 140 FTG T2L FE 0.0 100 -3.0 H.S. 52.8 400.0 0.003 TL 563.25 PV Pipe: 308 -1608.2 10.520 FL 160.00 FE 1.1 100 -3.0 H.S. 52.8 400.0 5.9 140 FTG T FE 0.0 103. -3.0 0.0 53.9 0.0 0.004 TL 244.30 PV Pipe: 309 -1608.3 10.520 PL 288.00 PF 1.3 101 -3.0 0.0 53.9 0.0 5.9 140 FTG ---- FE 0.0 102 -3.0 SRCE 55.2 (N/A) 0.004 TL 288.00 PV NOTES (HASS): Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38050722 granted by HAS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.131 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.9 ft/sec at pipe 30. Available pressure at source node 102 under full flow conditions is 58.60 psi with a flow of 1659.68 gpm. PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 20 DATE: 10/19/2018 C:\PROGRIU4 FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEU. ChkViv BfyVlv GatVlv AlmChk DPVlv NPTee 2.635 8.24 16.47 5.49 19.22 9.61 1.37 13.73 13.73 16.47 6.357 17.60 37.72 11.32 40.23 12.57 3.77 35.21 35.21 37.72 8.249 21.14 41.11 15.27 52.85 14.09 4.70 36.41 36.41 41.11 8.510 24.60 47.84 17.77 61.51 16.40 5.47 42.37 42.37 47.84 10.520 27.89 63.38 20.28 69.72 24.08 6.34 46.90 46.90 63.38 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil ChkVlv BfyVlv GatV1v AlmChk DPVlv Tee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 E 0 0 '0 0 0 44 U) 04 0 0 0 a) 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 21 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler 0 0 0 0 0 0 0 • • • • 0 0 0 0 0 . 0 0 0 • co rl- 'D If) C') ('4 0 I 0a:r1cnc,)a:r) _-04U)--4--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 22 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, Ca - REMOTE #3/Meat-Deli Cooler WATER SUPPLY CURVE 72+ 66+ 60+ \ I \ IX \ 54+ \ I \\ I \ I \ P 48+ \ R I \\ E I \ S I \ S42+ \ U I * <-40.0 psi 8 4060 gpm R I Flow Test Point E 36+ ( I P I S I I 30+ ) 24+ 18+ 12+ LEGEND U I X = Required Water Supply 55.16 psi 8 1608.3 gpm 6+ I 0 = Available Water Supply I 58.85 psi 8 1608.3 gpm ' 0++-+--.-+----+-----+------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) ff C-202-() LINDLEY FIRE PROTECTION CO. 1109 N. ARMANDO STREET ANAHEIM, CA 714-535-5761 LIC. # C161C34 NO. 1037930 HYDRAULIC CALCULATIONS FOR COSTCO #462 CARLSBAD 951 PALOMAR AIRPORT ROAD CARLSBAD, CA 92011 POS FREEZER/COOLER PRODUCE COOLER MEAT DELI COOLER DATE: 05-31-2020 MATERIAL SUBMITTAL Contents SECTION 1 - Piping Wheatland Piping (schedule 10/40) SECTION 2 - Fittings and Couplings Anvil Threaded Fittings Viking Grooved Fittings Viking Rigid Couplings Viking Flexible Couplings Anvil Mechanical Tees SECTION 3 - Miscellaneous Top Beam Clamp Pipe Ring All Thread Rod Retaining Strap Surge Restrainer SECTION 4 - Sprinklers Viking V545, Recessed Dry Pendent Sprinkler Viking Dry Sprinkler Boot Viking Quick Response Pendent Sprinkler SECTION 1 Steel Fire Sprinkler Pipe t Wheatland 4 DIVISION OF ZEKEL MAN INDUSTRIES Wheatland Tube Fire Sprinkler Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers and contractors across the continent depend on us for steel fire sprinkler pipe and a number of proprietary products— always in stock and ready to deliver. 100% compatibility We guarantee our steel pipe is 100% compatible with fire protection systems that use only steel pipe. Why risk incompatibility? Wheatland's complete line of steel sprinkler pipe makes design easy and brings you peace of mind.* Accurate and Efficient Our products help you work safer and smarter—not harder. With our extensive in-house capabilities, we offer the shortest production cycle times in the industry, and we deliver to you accurately and on time, every time. 'Wheat/and Tube has never warranted compatibility between its steel pipe products and CPVC products. Green and Sustainable Our steel fire sprinkler pipe contains recycled steel and provides decades of reliable service. At the end of its life, the steel may be almost fully recycled, supporting your green policies. Zekelman Industries Wheatland Tube is a division of Zekelman Industries, the largest independent manufacturer of steel hollow structural sections (HSS) and steel pipe in North America. We leverage our 100-plus years of pipe and tube manufacturing experience and expertise to produce 2 million tons of pipe and tube annually. Backed by Zekelman Industries, you can count on Wheatland for strength, innovation and service - bringing exceptional value to your business. WLS Schedule 30 Light Wall t'ó Sc!e 41) Wheatland's WLS Schedule 30 steel fire sprinkler pipe is a threadable, light-wall steel pipe approved for working pressures up to 300 psi. TECHNICAL DATA WT./FT. WT./FT PCS./1 TON PCS./1 TON NIPS NOM ID (LBS.) HO FILLED LIFT 21 LIFT 25 1 1.087 1.462 1.865 70 60 1¼ 1.426 1.928 2.621 55 45 11/2 1.650 2.370 3.297 45 40 2 2.125 3.004 4.542 35 30 SPECIFICATIONS NPS NOM OD NOM ID ULCR WLS - WLS Schedule Schedule - WLS 11 Schedule Nominal PCs./ Pcs./ -- 10 40 J 40 wt./ft. Lift 21 Lift 25 1 .315 1.087 - 1.049 0.57 1.00 1.462 70 60 1'/4 1.660 1.426 1.442 1.380 0.46 1.00 1.928 55 45 1½ 1,900 1.650 1.682 1.610 0.64 1.00 2.370 45 40 2 2.375 2.125 2.157 2.067 0.52 1.00 3.004 35 30 * Calculated using Standard UL CR1? formula, UL Fire Protection Directory, Category VIZY. The CRR is a atio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1. 0), WLS Meets or Exceeds These Standards: ASTM A795, Type F, Grade A Hot-dip galvanized finish meets FM requirements for dry systems UL® and C-UL Listed and FM Approved NFPA®13 ANSI®/ASME B1.20.1 pipe threads Finished in black or hot-dip galvanized When hot-dip galvanized, approved for dry system applications Available in standard 21' or 25' lengths; custom lengths may be ordered Saves on freight and installation costs Mega-Flow ID up to 7% larger than Schedule 10 and 11% larger than Schedule 40 Saves freight, labor and installation costs Standard hanger spacing (15') Available in standard lengths; custom lengths can be ordered ILL Wheatland's Mega-Flow is an engineered, light-wall steel sprinkler pipe that offers ID up to 7% larger than Schedule 10 and 11% larger than Schedule 40 for improved hydraulics. Mega-Flow saves freight, labor and installation costs with standard hanger spacing (15') and standard and custom lengths. With its proprietary mill coating, Mega-Flow is an excellent alternative to standard wall products so you can downsize your entire sprinkler system with the same or greater quality. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOM ID (LBS.) H2O FILLED PCS./LIFT 21 24 25 11/4 1.530 1.108 1.904 61 1419 1622 1690 1'/z 1.740 1.556 2.586 61 1993 2278 2373 2 2.215 1.961 3.631 37 1524 1741 1814 21/2 2.707 2.504 4.998 30 1578 1803 1878 3 3.316 3.349 7.090 19 1336 1527 1591 4 4.316 4.331 10.669 19 1728 1975 2057 6 6.395 8.000 21.900 10 1680 1920 2000 Roll groove available from mill inventory SPECIFICATIONS Proprietary mill coating provides superior NPS NOM OD r NOM ID ULCRR MEGA-FLOW primer for printing Mega-Flow - Schedule 10 Schedule 40 Mega-Flow L '4O Schedule Nominal wt./ft. Pcs./Lift - 1Y4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 1% 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 21/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 0.75 1.00 8.000 10 Calculated using Standard UL CRR formula. UL Fire Protection Directory, Category VIZY. The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Mega-Flow Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for use with roll grooved, swage grooved, plain-end couplings and welded joints for wet, dry preaction and deluge systems FM Approved for roll grooved, plain-end and welded joints for wet systems NFPA 13 and NFPA 14 ID 3.6% larger than Schedule 40 Saves costs in threadable applications Superior flow characteristics Can be joined by screwed, grooved or plain-end fittings, or welded Threads smoothly and easily; requires no thread warning Proprietary mill coating extends shelf life, makes painting quicker and easier Approved for standard hanger spacing Mega-Thread Wheatland's Mega-Thread is an engineered, light-wall steel sprinkler pipe that offers ID 3.6% larger than Schedule 40 for superior flow. Mega-Thread saves costs in threadable applications and can be joined by screwed, grooved or plain-end fittings, or welded. With its proprietary mill coating, Mega-Thread is an excellent Schedule 40 alternative that threads smoothly and easily so you can downsize your entire sprinkler system with the same or greater quality. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WI.! LIFT WT./LIFT NPS NOM ID (LBS.) H20 FILLED PCS./LIFT 21 24 25 1 1.087 1.462 1.865 70 2149 2456 2559 11/4 1.416 1.989 2.674 51 2130 2435 2536 11/2 1.650 2.370 3.297 44 2190 2503 2607 2 2.117 3.094 4.621 30 1949 2228 2321 SPECIFICATIONS NPS NOM CID NOM ID ULCRR MEGA-THREAD Mega- Schedule Mega- Schedule 1 LW T Pipe Nominal PCs /Lift - , Thread 40 Thread .L 40 wt./ft. 1 1.315 1.087 1.049 1.00 1.00 0.61 1.462 70 1'!. 1.660 1.416 1.380 1.00 1.00 0.39 1.989 51 11/2 1.900 1,650 1.610 1.00 1.00 0.31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 0.25 3.094 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRP is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). Mega-Thread Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for wet, dry and preaction sprinkler systems FM Approved for use in wet systems Hot-dip galvanized finish meets FM requirements for dry systems NFPA 13 and NFPA 14 Rated 300 psi working pressure GL Galvanized, Light Wall, Threadable Ideal for exposed, open areas Wheatland's GL steel fire sprinkler pipe is an OD galvanized, lighter-wall, threadable product. The nominal OD provides improved hydraulics—resulting in an exceptional value. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WI.! LIFT WT./LIFT NPS NOM ID (LBS.) H 2 0 FILLED PCS./LIFT 21 24' 25 Ideal for branch line use 1 1.103 1.370 1.701 91 2618 2992 3117 in wet, dry, preaction or 11/4 1.448 1.761 2.365 61 2256 2578 2686 deluge systems 11/2 1.688 2.033 2.875 61 2604 2976 3100 Comparable mechanical 2 2.153 2.686 4.142 37 2087 2385 2485 strength to Schedule 40 Readily paintable SPECIFICATIONS galvanized exterior NPS NOM ID UL THREADED CRR GL Reduces freight GL Schedule 40 GL Schedule 40 a- Nominal I pcs,LIft Thread and installation costs 1 1.103 1.049 0.61 1.00 1.00 1.370 91 1% 1.448 1.380 0.39 1.00 1.00 1.761 61 11/2 1.688 1.610 0.31 1.00 1.00 2.033 61 2 2.153 2.067 0.25 1.00 1.00 2.686 37 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY. The CPR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). GL Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Threaded and welded fittings are approved in accordance with NFPA 13 MLT Black, Light Wan, Threadable Wheatland's MLT is a black-coated, light-wall engineered product, with a nominal OD and reduced wall thickness that provide improved hydraulics. TECHNICAL DATA WT./FT. NPS NOM ID (LBS.) 1 1.103 1.370 11% 1.448 1.761 1½ 1.688 2.080 2 2.153 2.630 WT./FT. WT./LIFT WI.! LIFT WT./LIFT HaO FILLED PCS./LIFT 21' 24 25 1.701 91 2618 2992 3117 2.365 61 2256 2578 2686 2.875 61 2604 2976 3100 4.142 37 2087 2385 2485 Ideal for previously installed systems and expansions Saves freight and installation costs NPS NOM ID UL THREADED CRR*MLT MLT Schedule 40 MLT Schedule 40 Nominal Pc/Lift Thread wt./ft. 1 1.103 1.049 0.61 1.00 1.00 1.370 91 11/4 1.448 1.380 0.39 1.00 1.00 1.761 61 11/1 1.688 1.610 0.31 1.00 1.00 2.033 61 2 2.153 2.067 0.25 1.00 1.00 2.686 37 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY. The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). MLT Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Threaded and welded fittings are approved in accordance with NFPA 13 As mechanically strong as Schedule 40 pipe Easily paintable for a customized look Can be used in wet, dry, preaction and deluge systems Can he joined with threaded couplings, roll grooved or plain-end couplings, or welded Proprietary mill coating ensures clean, corrosion- resistant surface Outperforms and outlasts standard lacquer-coated pipe Easily painted, without special preparation Available with hot-dip galvanizing Also available in black WEIGHTS AND DIMENSIONS NOMINAL SIZE OD Wall Inches 1.315 0.133 11/4 1.660 0.140 1'/2 1.900 0.145 2 2.375 0.154 2½ 2.875 0.203 3 3.500 0.216 3% 4.000 0.226 4 4.500 0.237 S 5.563 0.258 6 6.625 0.280 SCHEDULE 40 Wt./Ft. Ibs./ft. HO Filled 1.68 2.055 2.27 2.922 2.72 3.602 3.66 5.109 5.80 7.871 7.58 10.783 9.12 - 10.80 16.311 14.63 23.262 18.99 31.498 Schedule 10 and Schedule 40 Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality-not to mention reliable, long-lasting performance. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WI.! LIFT WT./LIFT NPS NOM ID (LBS.) H20 FILLED PCS./LIFT 21 24 25 11/4 1.442 1.807 2.514 61 2315 2645 2756 1'/2 1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.640 4.222 37 2051 2344 2442 2% 2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.960 40.086 7 2493 2849 2968 SCHEDULE 10 SPECIFICATIONS NOMINAL NPS NOM OD NOM ID NOMINALWALL WEIGHT UL PIECES In. mm in. mm in. 1:: mm Ibs./ft. kg/rn CRR' Lift 1¼ 1.660 42.2 1.442 36.6 0.109 2.77 1.81 2.69 7.3 61 11/2 1.900 48.3 1.682 42.7 0.109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 0.109 2.77 2.64 3.93 4.7 37 2% 2.875 73.0 2.635 66.9 0.120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 0.120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 0.120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 0.134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 0.134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 0.188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CR1? formula, UL Fire Protection Directory Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NPS NOM OD NOM ID NOMINAL WALL WEIGHT UL PIECES In. mm in. mm in. [mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.00 70 1¼ 1.660 42.2 1.380 35.1 0.140 3.56 2.27 3.39 1.00 51 1% 1.900 48.3 1.610 40.9 0.145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CPR formula, UL Fire Protection Directory Category VIZY The CR1? is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). Schedule 10 and Schedule 40 Meet or Exceed These Standards: ASTM A135, Type E, Grade A (Schedule 10) • FM Approved ASTM A795, Type E, Grade A (Schedule 40) NFPA 13 UL and c-UL Listed SPECIFICATIONS NPS NOM OD NOM ID ULCRR WST WST Schedule 40 WST Schedule 40 Nominal Pcs./Lift 1 1.315 1.185 1.049 2.17 1.00 0.87 91 1¼ 1.660 1.530 1.380 1.40 1.00 1.11 61 11/2 1.900 1.770 1.610 1.11 1.00 1.27 61 2 2.375 2.245 2.067 0.90 1.00 1.60 37 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). The average CPR values shown above are higher than any threaded sprinkler pipe (except 2). WST's larger ID can often lead to superior hydraulics and down-sizing of pipe systems. WST Schedule 5 Light Wall h-strrtIi, . . . . . . . . . . . Wheatland's Super Tube (WST) is a light-wall Schedule 5 product that's UL and C-UL Listed, and FM Approved for use with standard roll grooved and welded joining methods. Finished in black Large ID for better hydraulics and downsizing tubing requirements TECHNICAL DATA WT./FT. NPS NOM ID (LBS.) 1 1.185 0.869 11/4 1.530 1.108 11/2 1.770 1.275 2 2.245 1.605 WT./FT. H 2 0 FILLED PCS./LIFT 1.346 91 1.904 61 2.340 61 3.319 37 WT./LIFT WT./ LIFT WT./LIFT 21 24' 25' 1661 1898 1977 1419 1622 1690 1633 1867 1944 1247 1425 1485 Super lightweight Outstanding hydraulics Fast installation Approved for use with flexible pipe couplings for the roll grooved joining method High corrosion- resistance ratios Standard hanger spacing WST Meets or Exceeds These Standards: ASTM A795/ASTM A135 UL and C-UL Listed and FM Approved New York city MEA #259-91-M Dade county, Florida, 92-1210 About Wheatland Tube Wheatland Tube, a division of Zekelman Industries, produces a wide range of steel tubular products, including standard steel pipe, galvanized mechanical tubing, fence framework, fire sprinkler pipe, electrical conduit, elbows, couplings and nipples. For more information, contact Wheatland Tube at: 800.257.8182 or info@wheatland.com Or, visit our website at wheatland.com Follow us on: 0 4 inkedin.com/company/zekelman-industries Q Q CAST BROM ii:i Awl- _______ Class 125 (Standard) FIG. 3360 Cross FIGURE :J.1f Nominal Size Maximum Dimension A Approx. Wt. Each Working PressureA In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 300 1.50 1.54 25 2065 38.10 0.70 1¼ 300 1.75 2.40 32 2065 44.45 1.09 11/2 300 1.94 3.10 40 1 2065 1 49.276 1 1.41 2 300 2.25 4.00 50 2065 1 57.15 1 1.81 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. c®us LISTED APPROVED dngs/Approval Details and Limitations, our website at enr,w.anvilintl.com or act an Anvil' Sales Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME 81.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. PROJECT INFORMATION Project: APPROVAL STAMP LjApproved Address: E] Approved as noted Contractor: El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 DUCTILE IRON THREADED FITTINGS FIG. 3207 Cross A —s—A FIGURE 3207 -s :1.1* I I Nominal Size Maximum Dimension A Approx. WI. Each Working PressureA In. (mm) PSI (kPa) In. (mm) tbs. (kg) 1 500 1.50 0.98 25 1 3450 3810 0.44 1¼ 500 1.15 1.50 32 3450 44.45 0.68 1/2 500 1.94 1.90 40 3450 49.27 0.86 2 500 2.25 2.95 50 1 3450 1 57.15 1 1.34 A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. c®uS LISTED APPROVED tens/Approval Details and Limitations, our website at www.anvilintl.com or act an Anail' Sales Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION Project: APPROVAL STAMP Li Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Sl'l-/UI-1.15 LTOO APPROVED s/Approval Details and Limitations, website at www.anvilintl.com or on Anvil' Sales Representative. <F~~ CAST BRON THREADED 0:07TINGS (~).AWIL , Class 125 (Standard) FIG. 3351 900 Elbow [-IuJ:1*cI.1 900 I:I•\YAT Nominal Size MaximumDimension Working PressureA A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 300 1.50 0.84 25 2065 38.10 0.38 11/4 300 1.75 1.34 32 1 2065 44.45 0.61 P12 300 1.94 1.80 40 2065 49.27 0.82 2 300 2.25 2.90 50 2065 57.15 1.32 2½ 300 2.70 4.75 65 2065 68.58 1 2.15 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. PROJECT INFORMATION APPROVAL STAMP Project: Ll Approved Address: Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 CAST IRON THREADED FITTINGS Class 125 (Standard) FIG. 3387 Cored Plug T-T t p1j c®us LTEO APPROVED For Usdngs/Approval Delads and Limitations, visit our web site at vnsw.anvilintl.cnm or contact an Anvil' Sales Representative. FIGURE 33:b'A CORED PLUG Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1/2* 300 0.94 010 15 2065 23.87 0.05 Y4 300 1.07 0.17 20 2065 27.17 0.08 1 300 1.25 0.28 25 1 2065 31.75 0.13 1¼ 300 1.36 0.44 32 2065 34.54 0.20 1½ 300 1.45 0.62 40 2065 36.83 0.28 2 300 1.56 0.91 50 2065 1 39.62 0.41 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. Dimensions: ASME B16.14 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. A Pressure . Temperature Ratings in accordance with ASME 516.4 Class 125 PROJECT INFORMATION APPROVAL STAMP Project: U Approved Address: U Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 <E~~ CAST BROM THREADED IFUTTINGS (~) A !R.!.~01 Class 125 (Standard) FIG. 3358 Straight Tee A FIGURE 3358 - STRAIGHT TEE Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Eo(h In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 300 1.50 1.21 25 1 2065 38.10 0.55 11/4 300 1.75 1.87 32 2065 44.45 0.85 1/2 300 1.94 2.51 40 2065 49.27 1.14 2 300 2.25 3.96 50 2065 57.15 1.80 21/2 300 2.70 6.45 65 1 2065 1 68.58 1 2.93 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. :®us LffD APPROVED gs/Apprnaal Details and Limitations. Ui website at naiw.anvitintl.com or it an Anvil Sales Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. PROJECT INFORMATION APPROVAL STAMP Project: J Approved Address: Li Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: * Notes 2: SPF/Cl-1 .15 CAST IRON THREADED FITTINGS (~AWIL Class 125 (Standard) FIG. 3367 Reducing Coupling -®us LmIED APPROVED ListngslApprnaal Details and Limitations, visit our website at www.anvilintl.cnm or contact an Anvil Sales Representative. [cjIJ:]: IJII[e Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) lbs. (kg) Ix½ 300 1.70 0.62 25x15 2065 43/8 0.28 1 xY4 300 1.70 0.80 25x20 2065 43/8 0.6 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. PROJECT INFORMATION APPROVAL STAMP Project: J Approved Address: J Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 DUCTOLE 0910M THREADED Fumms FIG. 3224 Cap IA c®us LThfl APPROVED For Listings/Approval Details and Umilaliuns, visit our website at www.anvihntl.com or contact an Anvil Sales Representative. FIGURE ?1CAP Nominal Size Maximum Dimension A Working PressureA Approx. Wt. Ea(i In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 11/4 500 1.28 0.43 32 3450 1 32.51 0.20 P12 500 1.33 0.60 40 3450 33.78 1 0,27 2 500 1.45 0.91 50 3450 36.83 1 0.41 A - Working Pressure Ratings are for reference only and based on Sch. 4C pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. 1PROJECT IlllINFORMATI ON 1 Project: Li Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 tiED APPROVED Approval Details and Lirrdtatiuns, ,ebsite at wean anvilintl.csm or Anvil' Sales Representative. 10 DUCTILE IRON THREADED FITTINGS &.AWIL FIG. 3201 900 Elbow - A A 3201 IFIGURE 900 ELBOW I Nominal Size Maximum Working Pressureg, Dimension A Approx. WI. Each In. (mm) PSI (kPo) In. (mm) lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 1¼ 500 1.75 0.90 32 3450 44.45 0.41 1/2 500 1.94 1.20 40 1 3450 49.274 0.54 2 1 500 2.25 1.85 50 3450 57.15 0.84 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION Project: APPROVAL STAMP Lj Approved Address: Ii Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1.15 FIG. 3205 Straight Tee I A 'It c®us L1EO APPROVED tings/AppuauI Details and tjrnitatiuns, our website at www.orryilintl.com or act an AnaiI Sales Representative. DUCTILE .I;.]ITlI ;i.1 '] D F077INGS FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) Ihs. (kg) 1 500 1.50 0.85 25 3450 33.10 0.39 1/4 500 1.75 1.22 32 1 3450 44.45 0.55 lIt 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 1 57.15 1 III A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintf .com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fillings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron Fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: LJ Approved Address: U Approved as noted Contractor: LJ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: I SPF/Dl-1 .15 The latest VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: http://vikinggroup.mobi/p/46374 I of 2 GROOVED COUPLING 4J G SAM MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com DESCRIPTION VGSO Model V-7705 Standard Flexible Couplings are available in sizes 1" through 12". Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGS8 Standard Flexible Couplings are manufac- tured at 1S09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are availa- ble (conforming to ASTM A153); when order- ing, add a G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AW\NA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel MIP Model V-7705 Standard Flexible Coupling For Table tLii Nominal P1e Max Working Max End Axial Dimensions Bolt Size Weight Size 0 D Pressure Displacement A B Cr in (mm) In (mm) PSI (Bar) Load Lbs/kN in (mm) No in (mm) Lbs (Kgs) in (mm) in (mm) in (mm) 1 1.315 300 406 0.0625 2.2 3.94 1.77 2 3/8 x 1-3/4 1.3 (25) (33) (21) (1.75) (1.6) (56) (100) (45) (M10 x 45) (0.6) 1.25 1.66 300 649 0.0625 2.58 4.09 1.85 2 3/8 x 2-1/8 1.4 (32) (42) (21) (2.79) (1.6) (66) (104) (47) (M10 x 55) (0.6) 1.5 1.9 300 850 0.125 2.82 4.25 1.815 2 3/8 x 2-118 1.6 (40) (48) (21) (3.66) (3.2) (72) (108) (47) (M10 x 55) (0.7) 2 2,375 300 1330 0.125 3.39 5.12 1.89 2 3/8 x 2-1/8 1.9 (50) (60) (21) (5.71) (3.2) (86) (130) (48) (M10 x 55) (0.9) 2.5 2.875 300 1950 0.0625 3.82 5.63 1.89 3/8 x 2-1/8 2.0 (65) (73) (21) (8.37) (1.6) (97) (143) (48) 2 (M10 x 55) (1.9) 3 3.5 300 2885 0.125 4.49 6.42 1.93 2 1/2 x 3 3.1 (80) (89) (21) (12.41) (3.2) (114) (163) (49) (M12 x 75) (1.4) 4 4.5 300 4771 0.125 5.83 7.80 2.05 2 1/2 x 3 4.6 (100) (114) (21) (24.77) (3.2) (148) (198) (52) (M12 x 75) (2) 5 5.563 300 7290 0.125 6.79 9.25 2.09 2 5/8 x 3-1/2 6.3 (125) (141) (21) (32.45) (3.2) (173) (235) (53) (M16 x 90) (2.9) 6 6.625 300 10340 0.125 7.91 10.55 2.13 2 5/8 x 3-1/2 7.3 (150) (168) (21) (46.02) (3.2) (201) 1 (268) (54) (M16 x 90) (3.3) 8 8.625 300 17525 0.25 10.35 13.27 2.44 2 5/8 x 3-1/2 12.1 (200) (219) (21) (78) 1 (6.4) (263) (337) (62) (M16 x 90) (5.5) 10 10.75 300 27228 0.125 12.76 15.51 2.62 2 3/4 x 4-3/4 19.7 (250) (2 3) (21) (121.19) (3.2) (324) (394) (67) (M20 x 120) (8.9) 12 12.75 300 38302 0.189 14.65 17.72 2.62 2 7/8 x 6-1/2 25.1 (300) (330) (21) (170.47) (4.8) (372) 1 (450) (67) (M22 x 65) (10.9) m No. F 021214 16.03.04 Rev 16.1 Reolaces form No. F 021214 Rev 15.1 (Reformatting and corrections) 2 of 2 GROOVED COUPLING '14 S MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 4. INSTALLATION Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Refer to the following VGS® Technical Data Sheets for detailed installation instructions: Grooved Coupling Installation Guide (Form No. F_031114) Pipe End Preparation Guide (Form No. F031214) Rubber Gasket Installation Guide (Form No. F_031014) Table 2: V-ZO5 (Rigid) and V-7705 (Flexible) VGS Coupling Gaskets Compound Grade Color Code Recommended Services Maximum Temp. Range Green Stripe* Good for cold & hot water up to +230°F(+1100C). Also good for services for water with acid, water with Purple Stripe** chlorine, deionized water, seawater and waste water, 30°F(34°C) EPDM E dilute acids, oil-free air, and many chemicals. to Green and Purple Not Recommended for petroleum oils, mineral oils, +230°F(+1100c) Stripe—solvents, and aromatic hydrocarbons. *Lubricated **Composition Change, Lubricated ***Additional Color Coding, Lubricated Note: Additional Lubricant is not required. Note: All other gasketed prducts (i.e. reducing coupling, mech tee, etc.) have never been pre-lubricated. These products have always been, and are today, marked with a single green stripe. Refer to the latest edition of the VGS® Technical Data Sheets. For additional information contact Viking Technical Services. Table 3: Approved Pipe and End Types W7705 Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Goove - Schedule 30, Roll Groove - Allied Tube & Conduit, "XL" -Allied Tube & Conduit, "BLT" -Allied Tube & Conduit, "Dyna-Thread" - Wheatland Tube, "Mega-Thread" - Schedule 10, Roll Groove -Allied Tube & Conduit, "Dyna-Flow" - Bullmoose Tube, "EDDY-Flow" - Bullmoose Tube, "EDDYlite" - Wheatland Tube, "Mega-Flow" Form No. F_021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 (Reformatting and corrections) I of 2 GROOVED COUPLING MODEL V-Z05 AND V-Z07 '4 4S STANDARD RIGID COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945:9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 1. Ut.klr I ION VGSO Model V-Z05 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 8". VGSO Model V-Z07 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 10" with Gap Seal gaskets available for sizes up to 8" under Model V-Z05F. Model V-Z07 is not available with Gap Seal gaskets. Fitting solutions are avail- able in a number of styles and configurations to support a variety of applications. VGS® Standard Rigid couplings are manufactured at 1S09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. The most recent VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan the code below to visit our Mobile website: oIo Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 I '- Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are avail- able (conforming to ASTM Al 53); when or- dering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AW\NA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA Table r Nominal Pipe Max. Working '. Dimensions Bolt Size Size 0 D Pressure Max End Axial A B Weight Load Lbs/kN Displacement No f in Lbs/Kg I in (mm) in (mm) PSI (Bar) in (mm) in (mm) in (mm) V205 and V-Z05F 1.25 1.66 300 649 0-0.05 2.58 4 1.85 2 3/8 2 1/8 1.5 (32) (42.2) (21) (2.8) (0 - 1.2) (66) (102) (47) - (0.7) 1.5 1.9 300 850 0-0.05 2.83 4.33 1.85 2 3/8 2 1/8 1.7 (40) (48.3) (21) (3.66) (0-1.2) (72) (110) (47) - (0.8) 2 2.375 300 1330 0-0.07 3.35 4.62 1.89 2 3/8 2 3/4 1.9 (50) (60.3) (21) (5.71) (0-1.7) (85) (118) (48) - (0.9) 2.5 2.875 300 1950 0-0.07 3.82 5. 1.89 2 x -24 3/8 2 3/4 2.1 (65) (73) (21) (8.37) (0-1.7) (97) (133) (48) (0.9) 3 3.5 300 2885 0-0.07 4.49 5.91 1.93 2 2.7 (80) (88.9) (21) (12.41) (0-1.7) (114) (150) (49) 3/8 x 2- 3/4 (1.2) 4 4.5 300 4771 0-0.16 5.75 7.48 2.17 2 1/2 3 4.3 (100) (114.3) (21) (24.77) (0-4.1) (146) (190) (55) (2) 5 5.563 300 7290 0-0.16 6.87 9.11 2.15 2 1/2 3 x 5.8 (125) (141.3) (21) (32.45) (0-4.1) (175) (232) (55) (2.6) 6 6.625 300 10340 0-0.16 7.87 10.24 2.17 2 5/8 5 5/16 (150) (168.3) (21) (46.02) (0-4.1) (200) (260) (55) - (3.2) 8 8.625 300 17525 0-0.19 10.28 12.89 2.52 2 13.3 (200) (219.1) (21) (78) (0-4.8) (261) (328) (65) 5/8 x 5- 5/16 (6) V.Z07* 10 10.75 300 27190 0-0.13 12.99 15.59 2.5 2 7/8 x 6-1/2,, 23.5 254 273 21 123 0-3.2 330 396 64 10.7 Not available with gap seal Form No. F020614 16.03.04 Rev 16.1 Replaces form No. F_020614 Rev 15.1 (Reformatting and corrections) 2 of 2 GROOVED COUPLING 5 MODEL VZO5 AND V207 STANDARD RIGID N4G COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 4. INSTALLATION Refer to the following VGS® Grooved Coupling Installation Guide (Form No. F_031114), Pipe End Preparation Guide (Form No. F_031214), and Rubber Gasket Installation Guide (Form No. F_031014) for detailed instructions regarding installation. Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Compound Table 2: V205 (Rigid) and V-7705 (Flexible) VGS Coupling Gaskets Grade Color Code Recommended Services Maximum Temp. Range Green Stripe* Good for cold & hot water up to +230°F(+1100C). Also good for services for water with acid, water with EPDM E Purple Stripe** chlorine, deionized water, seawater and waste water, 30°F(34°C) dilute acids, oil-free air, and many chemicals. to Green and Purple Not Recommended for petroleum oils, mineral oils, +230°F(+llo°c) Stripe""" solvents, and aromatic hydrocarbons. "Lubricated **Composition Change, Lubricated ***Additional Color Coding, Lubricated Note: Additional Lubricant is not required. Note: All other gasketed prducts (i.e. reducing coupling, mech tee, etc.) have never been pre-lubricated. These products have always been, and are today, marked with a single green stripe. Refer to the latest edition of the VGS® Technical Data Sheets. For additional information contact Viking Technical Services. riile 3: Approved P r.ip.iii,I 11T I Types V-z05 Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Goove - Schedule 30, Roll Groove - Allied Tube & Conduit, "XL" - Allied Tube & Conduit, "BLT" - Allied Tube & Conduit, "Dyna-Thread" - Wheatland Tube, "Mega-Thread" - Wheatland Tube, "GL" - Wheatland Tube. "MLT" - Schedule 10, Roll Groove -Allied Tube & Conduit, "Dyna-Flow" - Bullmoose Tube, "EDDY-Flow" - Bullmoose Tube, "EDDYlite" - Northwest Tube, "EZ-Flow" - Wheatland Tube, "Mega-Flow" V-Z07 Schedule 40, Cut Goove - Schedule 40, Roll Groove - Schedule 30, Cut Goove - Schedule 30, Roll Groove - Schedule 10, Roll Groove Form No. F_020614 16.03.04 Rev 16.1 Replaces form No. F_020614 Rev 15.1 (Reformatting and corrections) The latest VGS® Technical Data can be acessed at http:llwww.vikinggroupinc.com. Scan to visit our Mobile website: http://vikinggroup.mobi/p/46374 1 of 2 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs©vikingcorp.com DESCRIPTION VGS® Model V-7110, V-7111, V-7112, and V-7113 Elbows are available in sizes 1-1/4" through 12". Fitting solutions are available in a number of styles and con- figurations to support a variety of applications. VGS® grooved-end fittings are manufactured at 1S09001 certified facilities and are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to meet ASTM F1548 and ANSI/AWJVA C606 requirements for use with grooved mechanical couplings conforming to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZA Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM Al 53); when ordering, add a "G" suffix to the Model number. cEI Model V-7110 Model V-7112 90° Elbow 22-1/2° Elbow C.Ej C.EJ Model V-7111 Model V-7113 45° Elbow 11-1/4° Elbow Model V-7110DR 90° Drain Elbow TABLE :e -I GROOVED II:L,I1p CHART V-7110 V-7111 V-7112 V.7113 Nominal 90° Elbow 45° Elbow 22.5° Elbow 11.25° Elbow C-E C-E CE C.E Size Pipe O.D. in (mm) in (mm) in (mm) Lbs (Kgs) In (mm) Lbs (Kgs) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) 1.25 1.66 2.75 1.1 1.75 0.8 1.75 0.64 1.38 0.51 (32) (42) (70) (0.48) (45) (0.37) (45) (0.29) (35) (0.23) 1.5 1.9 2.75 1.3 1.75 1.01 1.75 0.97 1.38 0.68 (40) (48) (70) (0.59) (45) (0.45) (45) (0.44) (35) (0.31) 2 2.375 3.25 2 2 1.4 1.89 1.4 1.38 1 (50) (60) (83) (0.89) (51) (0.65) (48) (0.63) (35) (0.45) 2.5 2.875 3.75 2.9 2.25 1.95 2.01 1.83 1.5 1.39 (65) (73) (95) (1.3) (57) (0.9) (51) (0.83) (38) (0.63) 3 3.5 4.25 4.6 2.5 3.2 2.25 2.54 1.5 2.05 (80) (89) (108) (2.1) (64) (1.45) (57) (1.15) (38) (0.93) 4 4.5 5 7 3 4.85 2.87 4.87 1.75 2.78 (1 00) (125) (127) (3.18) (76) (2.2) (73) (2.21) (45) (1.26) 5 5.563 5.5 9.8 3.25 7.1 (125) (141) (140) (4.42) (83) (3.2) 6 6.625 6.5 13.8 3.5 9.26 3.11 8.89 2 6.04 (1 50) (168) (166) (6.27) (89) (4.2) (79) (4.03) (51) (2.74) 8 8.625 7.75 27.1 4.25 17.99 3.86 18.19 2 10.54 (200) (219) (197) (12.3) (108) (8.16) (98) (8.25) (51) (4.78) 10 10.75 9 50.6 4.75 32.34 4.37 33.03 2.7 22.8 (250) (273) 1 (229) (23.4) (121) (14.76) (111) (14.98) (68.5) (9.89) 12 12.75 10 75.4 5.25 42.31 (300) (325) (254) (32.2) ( (19.19) -- Form No. F_101515 16.12.15 Rev 16.1 Replaces Form No. F_101515 Rev 15.1 (Revised Fig 1) D Model V-711ODR 90 Drain Elbow 2 of 2 GROOVED FIlliNGS G SAN MODEL V-7110, V-7111, V-7112, V-7113 ELBOWS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 2: VGSIFT Model I' Dimensions Weight Nominal Size Pipe O.D. Lbs (Kg) C-E D E in (mm) in (mm) in (mm) in (mm) in (mm) 2 2.375 3.25 2.25 1.57 2.14 (50) (60) (83) (57) (40) (0.97) 2.5 2.875 3.75 2.75 1.53 3.1 (65) (73) (95) (70) (39) (1.4) 3 3.5 4.25 2.75 1.93 4.6 (80) (89) (108) (70) (49) (2.1) 4 4.5 5 2.75 2.48 7.3 (100) (114) (127) (70) (63) (3.3) 6 6.625 6.55 2.75 3.54 13.8 (150) (168) (166) 1 (70) 1 (90) (6.3) 8 8.625 7.8 3.27 4.49 27.1 (200) (219) (197) 1 (83) 1 (114) (12.3) Form No. F_101515 16.12.15 Rev 16.1 Replaces Form No. F_101515 Rev 15.1 (Revised Fig 1) Set Screw and Locknut Included Fig. 65XT-3/8 - Beam Clamp 3/4" (19.0) (221) Set Screw and Locknut Included 13/4" (34.9) c®Us USTED Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electra-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0. Beam Clamps ®TDLCO C®Us USTEO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65X1 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 - 1/2"..13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - 3/8 -16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8 -16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm( 65-1/2 1/2"_13 11/2' (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 5/8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65-1I2 11/4" (31.7) 55 (24.9) 65-I8 11/4" (31.7) 55 (24.9) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 13 by ETN Size Range - Secures 3/8 thru 7/8 rod in 1 increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Component of State of California OSHPD Approved Seismic Restraints System p FIG. 98 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener wlBreak-off Bolt Head Size Range - Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD. For additional load, spacing and placement information relating to OSHPD proiects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Fig. 100- All Thread Rod Full Lenath Size Range - Secures 3/8 thru 1112" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 m OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951 737,5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wvlwtolco.com Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6" pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters / Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 21/2 1/2* 53/4 41/4 1/8 600 41 3 1/2* 6 41/8 11/4 600 45 31/2 1/2* 7/8 51/4 21/8 600 52 4 5/8* 73/8 5 15/8 1000 59 5 5/8** 9 6/ 21/4 1250 97 6 3/4** 9/8 61/2 1/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH. 951.737.5599 • FAX, 951.737.0330 CUSTOMER SERVICE • 800 786.5266 www.foko.com H C®US LISTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed qDly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.780.5266 wwwfolco.com 470 VK544 VK545 VK546 ii Thread Size K-Factor 1-1/4" NPT (32 mm BSP) 11.2 (161.3 Metric) SIN Style VK544 Plain Barrel VK545 Adjustable Recessed VK546 Adjustable Standard Page 1 o 9 STANDARD RESPONSE i:ii[i..rIv DRY PENDENT ELO SPRINKLERS _N41KJWJ4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent ELO sprinklers are FM Approved for storage and non-storage applications. In certain FM cold storage installations, the dry ELO sprinklers can provide a design advantage with lower overall water demands. In these applications, the dry ELO must be installed on a wet pipe system, per FM data sheet 8-9. In non-storage applications, when used in dry or preaction systems, the sprinklers are designed to prevent water or condensation from entering the drop nipple before the sprinkler operates. Viking Standard Response Dry Pendent ELO Sprinklers are available in various finishes and temperature ratings to meet design requirements. The optional dry sprinkler boot assembly is intended to slow the exchange of air between the inside and outside of the freezer (or any dry sprinkler installation) to help prevent humidity and temperature differential in the area around the sprin- kler. Condensation can lead to ice build-up, which could inhibit sprinkler operation or cause premature operation. If using the insulating boot assemblies included with your sprinklers (optional for installation), follow the installation instructions in this technical data page. Insulating boot assemblies, if used, shall be installed on smooth, flat, and clean surfaces. There are specific installation situations, as with corrugated ceiling panels, where alternative penetration sealing methods may be utilized. For additional information contact Viking Technical Services. LISTINGS AND APPROVALS FM Approved: Classes 2013 and 2015 FM Refer to Approval Chart and Design Criteria on page 4 for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1-1/4" NPT or 32 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric**) for all listed and approved lengths. * FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). **Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass Fusible Link Assembly: Beryllium Nickel, coated with Polyurethane Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C36000 Pip Cap Adapter: Brass UNS-C36000 Orifice: Brass UNS-C36000 Tube: ERW Hydraulic Steel Tube Barrel End and Threads: QM Brass Support (Internal): QM Brass Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089M/B.) Page 2 of 9 STANDARD RESPONSE "si IF(JIS1G1 DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Dry Barrel Seals: (NOTE: 2 seals included with each VK544 and I with each VK545 or VK546): Seal: ASTM D1056 2A0/1 4015-EL EPDM-Butyl-PE Foam Rubber OR ASTM D1056 2A1 Neoprene/EPDM/SBR OR ASTM D1056 2C1 Neoprene/EPDM Over Seal Ring and Under Seal Ring: Cold Rolled Steel Finish: White Paint #10 Screws: Stainless Steel Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Temperatures and Finishes: Finish Brass Chrome - - White Polyester Suffix A F M-/W Temperature 165 F (74 C) 205 F (96 C) 280 F (138 C) Suffix C E G Ordering Information: Refer to Table 1. INSTALLATION Refer to the applicable FM Loss Prevention data sheets. Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to suppress the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Standard Response Dry Pendent Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench 19748** must be used for installing recessed dry sprinklers. J Step 1: Carefully slide the **A 1/2" ratchet is required wrench sideways around the (not available from Viking). sprinkler deflector. JJ Step 2: Carefully press the -l- wrench upward and turn J,.J I slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Wrench 19748W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F_040815 18.08.02 Rev. 18.1 Page 3 of 9 N1KJWJ*C l:II[.i•.7v STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: ORDERING sprinklerbase INFORMATION I the part number, add the suffix for the desired add the suffix for the desired Add the "A" Dimension Finish Temperature Rating. Size 1: Finishes 2: Temperature Ratings Sprinkler NPT BSP Description Suffix' Nominal Frame Max. Ambient Suffix Model Base Part No. Inch mm Rating4 Paint Color Ceiling Temperature 19830 1-1/4 -- Brass' A 165F(74°C) None 100 °F(38°C) C VK544 19831 -- 32 Chrome F 205 °F (96 °C) White 150 °F (65 °C) E VK545 19835 1-1/4 -- White Polyester M-/W 280 °F (138 °C) Blue 225 °F (107 °C) G 19836 -- 32 VK546 19840 1-1/4 -- 19841 -- - - 32 12 (305) 18 (457) The A" Dimension is the distance as 3. Available "A" Lengths 24 (610) measured from the face of the fitting T A Inches (mm) 30 (762) in which the sprinkler will be installed 36(914) to the face of the finished ceiling in the _ 42 (1067) protected area. See Figures 2, 3, and 4 48 (1219) Example: 19835FC12 is a VK545 with a Chrome finish and a 165 temperature rating with "A" dimension of 12 inches. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrench: Socket Wrench (for Recessed sprinklers): Part No. 19748W/B - requires a 1/2" ratchet (not available from Viking) Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 19730. Recessed Dry Escutcheon Cup: Base Part No. 19728. Dry Barrel Seals: (NOTE: 2 seals are included with each VK544 and I with each VK545 or VK546) Part No. 22089M/B Footnotes I. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. Based on NFPA 13 Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The VK544 is the only sprinkler available with a brass finish. The VK545 is not available with a 280 F (138 C) temperature rating. For Standard Adjustable and Plain Barrel sprinklers, use a pipe wrench applied on the inlet housing. Form No. F_040815 18.08.02 Rev. 18.1 Page 4 of 9 ' WARD RESPONSE J IF(IIIE. lII[s1U'7M DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart FM Standard Response ELO Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler SIN Style e Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 NPT BSP U.S. Metric3 Inches mm Base Part No.' (Refer also to Design Criteria below.) 19830 VK544 Plain Barrel 11/4" -- 11.2 -- 6" -- Al 19831 -- 32 mm -- 161.3 -- 153 Al 19835 VK545 Adjustable Recessed 1-1/4" -- 11.2 -- 6" -- B2 19836 -- 32 mm -- 161.3 -- 153 B2 19840 Adjustable Standard 11/4" -- 11.2 -- 6" -- A3 19841 -- 32 mm 161.3 -- 153 A3 Approved Finishes and "A" Dimensions Approved Temperature Ratings i - Brass, Chrome, and White Polyester, with "A" dimensions 12" to 48" (305 to 1,22 m) A- 165 °F(74 °C), 205 °F (96°C) and 280 °F (138 °C) 2- Chrome and White Polyester, with "A" dimensions 12" to 48" (305 to 1,22 m) B - 165 °F (74 °C) and 205 °F (96°C) 3 - Chrome, and White Polyester with a Chrome or White Polyester Sleeve and Escutcheon with "A" dimensions 12" to 48" (305 to 1,22 m) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ('A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. DESIGN CRITERIA - FM (Also refer to Approval Chart above.) FM Annroval Requirements: ELO Dry Pendent Sprinklers in the Approval Chart above are FM Approved as standard response, standard spray storage sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_040815 18.08.02 Rev. 18.1 Page 5 of 9 J II(IF1G ® STANDARD RESPONSE l.11I[.1i•'flf DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For "A" Dimension: Determine the distance from the face of the tee to the finished ceiling. Round to the nearest 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m). Per "A" dimension, the deflector will be located approximately 4" (102 mm) below the ceiling. (32 mm) tee Minimum ceiling opening diamter: A 1-2"(5lmm) ,.7 Maximum ceiling opening diameter: / 2-3/8" (61 mm) Finished ceiling - (21 mm) Sleeve finish - matches escutcheon (48 mm) 3-7/8" diameter (99 mm) Deflector at minimum ______ distance below ceiling. NOTE: To locate the - deflector at the minimum Deflector at maximum - distance below the ceiling, distance below ceiling. with no upward NOTE: To locate the adjustment available, deflector at the maximum order the dry pendent distance below the ceiling, 10" sprinkler as per the "A" with no downward 254 mm dimension. adjustment available, Maximum the dry pendent sprinkler 6" (153 mm) " longer than the A" 1(102 mm) dimension. 19 JMinimum Figure 2: Adjustable Standard Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 6 of 9 411QWJ4 NDARD RESPONSE I:II[iu.7f DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For A" Dimension: Determine the distance from the face of the tee to the finished ceiling. For adjustable recessed the "A" dimension must be a minimum of 12" (305 mm) up to 48" (1,22 m) in 6" (153 mm) increments. mm tee 1-1/4" NPT (32 mm) - A NOTE The sprinkler Minimum ceiling opening diameter: will be recessed 2-5/8" (67 mm) approximately 5/16" Maximum ceiling opening diameter: (8 mm) above the 3" (77 mm) finished ceiling with 5/8" (16 mm) verti- cal adjustment I--- available. Adjustment: 5/16" (8 mm) Minimum: I - - 1" (26 mm) Maximum: Finished ceiling 1-5/8" (43 mm) 3-5/8" (80 mm) Figure 3: Adjustable Recessed Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 7 of 9 'i II(IIs1G® STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For "A" Dimension: Determine the distance from the face of the tee to the base of the sprinkler. Round up to the next higher 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m) - 1-1/4" (32 mm) tee 1-1/4" NPT(32mm)--~' T A Outside diamter: 1-11/16" (43 mm) RL-LUMLLL-La t 2-1/16" (53 mm) Figure 4: Plain Barrel Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Install 1-1/4" NPT (32 mm BSP) threaded end of dry pendent sprinkler into the 1-1/4" NPT (32 mm BSP) outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (Class 125) Minimum ceiling opening diameter: 2" (51 mm) Maximum ceiling opening diameter: 2-3/8" (61 mm) i 13/16" \ (21 mm) Sleeve finish matches 3-7/8" escutcheon (99 mm) Exposed barrel L Ceiling "(48 mm) iiameter (Protected area) Page 8 of 9 STANDARD RESPONSE si II(II1Gi l:lI[u.7M DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Ambient Temperature of Protected Area*at the Discharge End of the Spunkier Exposed Barrel Ambient Temperature 40F(4C) 50'F(lO'C) 60'F(16C) Exposed Minimum Barrel Length"" Face of Tee to Top of Ceiling In. (mm) 40°F(4°C) 0 0 0 30°F(4°C) 0 0 0 20 °F(-7 °C) 4 (102) 0 0 10 °F(-12 °C) 8(203) 1(26) 0 0 °F(-18 °C) 12(305) 3(76) 0 -10 °F(-23 °C) 14 (356) 4 (102) 1(26) -20 °F(-29 °C) 14(356) 6 (152) 3(76) -30 °F(-34 °C) 16(406) 8(203) 4 (102) 40 °F(-40 °C) 18(457) 8(203) 4(102) -50 °F(46 °C) 20(508) 10(254) 6(152) -60 °F(-51 °C) 20(508) 10(254) 6(152) Seal the clearance space around the sprinkler to avoid leakage of air into the protected area and consequent formation of condensate around the frame, which could inhibit operation or cause premature operation. Refer to Figure 6 below. If humidity and temperature differential causes condensation on the exposed dry sprinkler, consider wrapping the exposed barrel with insulation, foam insulating tape, or equivalent. NOTE: To locate the deflector at the minimum distance below the ceiling, with no upward adjustment available, order the dry pendent as per the "A" dimension. Deflector at minimum distance below ceiling. iq (102 mm) Minimum do NOTE: To locate the - deflector at the maximum distance below the ceiling, with no downward adjust- 10 ment available, order the (254 mm) dry pendent sprinkler 6" Maximum (153 mm) longer than the "A"dimension. Deflector at maximum distance below ceiling. *The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. **The minimum required barrel length is not the same as the "A" dimension. Refer to Figures 2-4 for the "A" dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 5: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_040815 18.08.02 Rev. 18.1 Page 9 of 9 N41KJW*JCA STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Boot assembly (optional) / Part No. 22089M/W (or equivalent method) Clearance opening \._ Insulated ceiling Dry Sprinkler Seal on the Exterior of the ceiling p_L_7T_Seal Insulated ceiling Dry Sprinkler Seal Within the ceiling Figure 6: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089M/B.) Page 1 of 4 'sJ W*j l DRY SPRINKLER :ll[.11•.7y INSULATING BOOT ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION The Dry Sprinkler Boot is designed to be used with most models of dry sprinklers including ESFR to help seal the clearance space around the barrel. When properly installed, this seal decreases the potential for leakage of air through the opening in the ceiling or wall and consequent formation of condensate around the sprinkler connection on the system piping. In freezer installations, condensation can lead to ice build-up, which could inhibit sprinkler operation or cause premature sprinkler operation. The Dry Sprinkler Boot Assembly (optional) is intended to slow the ex- change of air between the inside and outside of the freezer (or any dry sprinkler in- stallation) to help prevent humidity and temperature differential in the area around the sprinkler. Insulating boot assemblies (optional) shall be installed on smooth, flat, and clean surfaces. The rubber seal is designed with a material that will not drip when exposed to open flame. This protects the deflector from acquiring material that would impede its water distribution characteristics. LISTINGS AND APPROVALS Install in accordance with applicable NFPA standards. Refer to Design Criteria for requirements that must be followed. NOTE: Laboratory approval of dry sprinkler boot assemblies are not required and use of these assemblies does not alter any of the listings or approvals for Viking dry sprinklers. Refer to the sprinkler technical data pages. TECHNICAL DATA Specifications: The boot consists of a rubber foam seal covered with a two-piece ring fastened to the ceiling, deck, or wall, with two screws. Outside Diameter: 6" (152 mm) Depth: 1" (25 mm) Material Standards: Seal: ASTM D1056 2A0/1 4015-EL EPDM-Butyl-PE Foam Rubber OR ASTM D1056 2A1 Neoprene/EPDM/SBR OR ASTM D1056 2C1 Neoprene/EPDM Over Seal Ring and Under Seal Ring: Cold Rolled Steel Finish: Clear Chromate over Zinc Plating #10 Screws: Stainless Steel Ordering Information: (Also refer to the current Viking price list.) Part Number Compatible Viking Sprinkler models - Dry Sprinklers: 22087M!W VKI60, VK184, VK150, VK154, VK158, VK152, VK156, VK162, VK166, VK163, VK164, VK250, VK252, VK254, VK153, VK157, VKI6I, VK168, VK169, VK172, VK176, VKI80, VK174, VK178, VK182, VK173, VK177, VKI8I, VK275, VK277, VK279, VK282, VK286, VK290, VK284, VK288, VK292, VK186, VK188, VK482 22089M/W ELO and ESFR Dry Sprinklers: VK502, VK504, VK544, VK545, VK546, VK547, VK548, and VK549 NOTE: ELO and ESFR Dry Sprinklers include at least 1 Insulating Boot; additional boots can be ordered separately. Form No. F_030107 18.08.02 Rev 18.1 Replaces Form No. F_030107 Rev 16.1 (Replaced 19330M/W with 22089M/W and 19398M/B with 22087M/B) Page 2 of 4 DRY SPRINKLER N11KJW E I[.iu.rM INSULATING BOOT ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Prepare the sprinkler installation opening as indicated in the installation instructions on Form No. F_080614 and the appropriate sprinkler technical data page. Then install the dry sprinkler through the clearance opening. Install the dry sprinkler on the piping per the instructions on page Form No. F_080614 and the dry sprinkler data page for the sprinkler model being used, taking care not to over-tighten or damage the sprinkler. Clean the contact surfaces of the dry sprinkler seal and the surface of the wall or ceiling. Slide the dry sprinkler boot over the dry sprinkler barrel and to the ceiling, deck, or wall until the seal rests against the surface of the ceiling, deck, or wall. Assemble the ring onto the seal, hold in place, and tighten the four screws through the holes provided in the assembly. NOTE: A #29 drill is required for a pilot hole in metallic ceilings, decks, or walls. 5. INSPECTIONS, TESTS AND MAINTENANCE A. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. Remove the system from service, drain all water, and relieve all pressure on the piping. Remove the dry sprinkler boot assembly. Using the special sprinkler wrench, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response charac- teristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Install a new Dry Sprinkler Boot Assembly. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. B. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combus- tion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. AVAILABILITY The Viking products are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Under Seal Ring ED #10 Tapping Screw -.. For 22087MM!: Fits 1-5/16" Seal t (33 mm) 0.D. Barrel ED ED (152 mm) 1" For 22089MM!: Fits 1-11/16" (25 mm) (43 mm) O.D. Barrel ED I Over Seal Ring I" I Figure 1: Dry Sprinkler Insulating Boot Dimensions Form No. F_030107 18.08.02 Rev 18.1 Page 3 of 4 DRY SPRINKLER NlKjw4j INSULATING BOOT ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Installation Requirements: Dry Sprinkler Boot Assembly 22087M1W is designed for use with all Viking dry sprinklers, except Dry Concealed Sprinklers. NOT for use with Viking dry concealed sprinklers or any non-dry type sprinkler. Dry Sprinkler Boot Assembly 22089M/W is designed for use with Viking Dry ELO and ESFR Sprinklers. Minimum Barrel Length: Refer to Figures 2 and 3 for the required minimum dry sprinkler barrel exposure length between the face of the sprinkler tee to the outside surface of the ceiling or wall. Clearance Opening Diameter: Refer to Figures 2 and 3. NOTE: The dry sprinkler boot must seat and seal against the smooth surface of the wall, ceiling, or deck in order to close the air gap. Sprinkler Fitting: Install the dry sprinkler into the outlet of malleable iron tee fittings per ANSI B 16.3 (Class 150) or cast iron threaded tee fittings per ANSI 16.4 (Class 125) only. Install in accordance with applicable NFPA standards. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Exposed Barrel Ambient Temperature Ambient 40r/4'C150'F/10'CIGOT/16C Temperature Exposed Minimum Barrel of Protected Areo.w at thE. Length* Face of Tee Discharge End to lop of the Celing of the Sprinkle or Surface of the \dod or Dry HSW Sprinklers tojOn) In. (mm) In. (mm) 40T (4C) 1 0 0 0 30F (-1C) 0 0 0 20F (-7'C) 4 (100) 0 0 10F (-12C) 8(203) 1(25A) 0 0F (-18C) 12 (305) 3 (76) 0 -10F (-23C) 14 (356) 4(102) 1(25A) -20F (-29C) 14 (356) 6 (152) 3 (76) -30'F (-34C) 16 (406) 8 (203 4 (102) -40T (-40C) 18 (457) 8(203) 4(102) -50F (-46C) 20(508) 10 (254: 6(152) -60F (-51C) 20(508)10(254 6(152) Ins-tall threaded end of dry concealed sprinkler Into the outlet of a malleable iron tee fitting per ANSI B 16,3 (Class 150) or cast Iron threaded tee fitting per ANSI 16.4 (Class 125) only. (Exposed - 6' Diameter Barrel) / (152 mm) OD Dry Sprinkler Boot "— Insulated Ceiling—" Ceiling Structure (Protected Area) *The protected area refers to the area below the ceiling (for pendent and HSV sprinklers). The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. EE1he minimum required barrel length is NOT the same as the 'A' or 'B' dimension, Refer to the figures in the dry sprinkler data pages for the 'A' or 'B' dimension, NOTE, Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities, Figure 2: Dry Sprinkler Insulating Boot Assembly and Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Shown with a Dry Pendent Sprinkk Form No. F_030107 18.08.02 Rev 18.1 Insulated CelUrig Structure STEP 1 INSTALL SEAL AROUND BARREL OF DRY SPRINKLER Page 4 of 4 $4J II(I INSULATING BOOT WJ4 ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com *10 TAPPING SCREW OVER SEAL RING Seat UNDER SEAL WOOD - NO PILOT HOLE REQUIRED METAL - DRILL PILOT HOLE FOR SCREWS Clearance -" Opening Insulated —" Ceiling Structure STEP 2 PLACE SEAL FLUSH WITH TOP OF FREEZER AND SECURE AROUND BARRELL Clearance Opening Insulated CeRlng Structure STEP 4 SECURE INSULATING RING TO TOP OF FREEZER WITH *10 TAPPING SCREWS Figure 3: Dry Sprinkler Insulating Boot Assembly - Installation Sequence (Dry Pendent Sprinkler Shown) Form No. F_030107 18.08.02 Rev 18.1 Replaces Form No. F_030107 Rev 16.1 (Replaced 19330M/W with 22089M/W and 19398M/B with 22087M/B) Page 1 of 6 'sj II(IIIG® MICROFAST® QUICK l:ll[s1iuuywa RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION The Viking Microfase Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 LPCB Approved (( CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 barJ Approvals ONLY is 5 psi (0.35 bar). Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. The minimum operating pressure for LPCB and CE Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Form No. F_033314 16.01.28 Rev 16.1 Replaces Form F_033314 Rev 15.2 (Revised temperature suffix designation) Page 2 of 6 MICROFAST® QUICK 4J I I(IFs1G RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1,4" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler .. Wrench Flat Clip 1 Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 16.01.28 Rev 16.1 Page 3 of 6 MICROFAST® QUICK \J IF(IF1E RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient"Bulb Classification Temperature Rating' Color Ceiling Temperature Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286°F (141 °C) 225°F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated Sprinkler for recessed pendent Carefully slide the wrench sideways around _ the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/13 for Recessed Pendent Sprinklers Form No. F_033314 16.01.28 Rev 16.1 Page 4 of 6 J II(II1G ® MICROFAST@ QUICK :RESPONSE PENDENT RINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart I (UL) r— Temperature KEY The Viking Microfast Quick Response Finish Pendent Sprinkler VK302 All - Estthe (if applicable) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number1 NPT BSP U.S. metric2 inches mm cULus' VdS LPCB I (E MZ~ 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X I Al I A1Z, B1Y D1Z, dY -- NOTICE - I7T1Below Availability (Contact r1aLocal 17IViking lOffice) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- -- 18021 VK302 I Pendent 1 1/2" 15 5.6 1 80.6 1 2-1/4 58 AlX, B1Y Al I AiX, B1Y D1X, ClY8 Dlx, C1Y9 -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 OF (57 CC), 155 OF (68 SC), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 SC), 200 OF (93 °C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatice Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter56 Y - Standard surface-mounted escutcheon or the (79 CC), and 200 OF (93 C) 2 - ENT5 Viking Microfaste Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 OF (68 CC), 175 OF (79 °C), and 3 - Chrome matic Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 C) Z - Standard surface-mounted escutcheon or the D - 155 OF (68 °C), 175 -F (79 °C), 200 OF Viking Microfaste Model F-1 Adjustable Escutcheon (93 °C), 286 F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1 008. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 16.01.28 Rev 16.1 Page 5 of 6 MICROFAST® QUICK ij II(IF1G ® l:II[.11u.7v.. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 (FM) Temperature )çy The Viking Microfast® Quick Response Finish AIX 4— Cscutcheon (if applicable) Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' Style NPT BSP U.S. metric2 Inches (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 1 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE - Product1I11 Limited tAvailability UT7 Viking Office) 06662B VK302 Pendent 1/2" 15 mm 1 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1 1/2" 15 mm 1 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200 OF Viking Micromatic Model E-1 Recessed (93 °C), 286 OF (141 °C) Approved Finishes Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 1 - Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 OF (93 °C) and Black Polyester' Viking Microfastn Model F-i Adjustable Escutcheon, C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 OF (141 °C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfastn Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 16.01.28 Rev 16.1