Loading...
HomeMy WebLinkAbout5791 VAN ALLEN WAY; ; FPC2021-0015; Permit(('ptyof PERMIT REPORT Carlsbad Fire Permit Print Date: 07/28/2021 Permit No: FPC2021-0015 Job Address: 5791 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121304500 Track #: Applied: 02/01/2021 Valuation: $2,082,950.35 Lot #: Issued: 02/11/2021 Occupancy Group: Project #: Finaled Close Out: 07/28/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: THERMO FISHER SCIENTIFIC MM2 -FIRE ALARM TI (ADDRESSABLE, 110 DEVICES) FPContractor: JJJ ENTERPRISES SALO MON GOMEZ 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Imploplop ElmcmRpmsm FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS THERMO FISHER SCIENTIFIC 5791 VAN ALLEN WAY CARLSBAD, CA 92008 FIRE ALARM SYSTEM tMATE'RIAL DATA1iS BILL OF MATERIALS NOTIFIER NFC-50/100: 50 WATT, 25 VRMS, EMERGENCY VOICE EVAC. CONTROL PANEL CSFM# 6911-0028:0265 NOTIFIER FCPS-24S6 REMOTE NAC POWER SUPPLY CSFM# 7315-0028:0225 NOTIFIER NP-200 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0028:0503 SYSTEM SENSOR SPSCWL SELECTABLE CANDELA SPEAKER/STROBE - CEILING MOUNT CSFM# 7135-1653:0503 SYSTEM SENSOR SCWL SELECTABLE STROBE ONLY - CEILING MOUNT CSFM# 7125-1653:0504 NOTIFIER INNOVAIRFLEX DNR DUCT DETECTOR CSFM# 3242-1653:0209 NOTIFIER NC-100R ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0230 0' Canadian DN-60813:A2 N OTIFIE R i ri-rtriFirst IiCommand Honeywell em at os~me . . General Notifier's First Command NFC-5011 OOC is a multipurpose emergency voice evacuation panel for fire applications, mass notification applications, or both. The First Command delivers 50 or 100 watts of audio power for distribution to up to eight speaker circuits (i.e. zones). The NFC-50/100C comes stan- dard with a single speaker circuit and a built-in 50 watt, 25V amplifier. A secondary 50 watt amplifier (NFC-BDA-25/70V) can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an additional 50 watts of audio power. An optional NFC-CE6 module added to the NFC-50/100C will upgrade the system to a maximum of eight speaker circuit outputs. All speaker output circuits can be wired in either Class B or Class A configuration. The NFC-50/ 100C has fourteen field programmable messages (up to 60 seconds each), built-in field configurable pre- and post- announce tone generators and a fully supervised Notification Appliance Circuit (NAC) with 2.0 amps of synchronized NAC power. The NFC-50/I00C includes three built-in Form-C relay contacts, (AC power, trouble and MNS active) a NAC follower and 500mA special application power. A built-in power supply delivers operational power and on board battery charger sup- ports charging up to 26AH batteries (NFC cabinet holds up to 18AH batteries). For fire protection applications, the NFC-50/100C is an adjunct (slave) to most ULC listed FACPs or as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification, the NFC-50/1 OOC can be activated by the NFW2-100C(-FR) and NFS-320C(-FR) and NFS2-640 when connected to the serial communication bus. Activation of the NFC-50/100C via other FACP's uses the eight on board Command Input Circuits (CMD's). Two of the eight CMD cir- cuits (CMD I & CMD 2) can be individually field programmed for activation by an FACP Notification Appliance Circuit reverse polarity and all eight can be activated by a contact clo- sure. In addition, the NFC-50/100C can be activated from a building's Private Branch Exchange (PBX) with the integral night ring feature. All NFC-50/I00C programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the NFC-50/1OOC supports both 25V and 70V speaker output operation. By adding a 70V transformer con- version module (NFC-XRM-70V) or an additional 70 volt sec- ondary amplifier (NFC-BDA-25170V) the system supports 70 volt speaker devices. The NFC-50/I00C can expand in order to accommodate larger or more complex installations. To add more control and increase system capacity, any combination of up to eight external remote consoles (including the NFC-LOC). TYPICAL APPLICATIONS Schools Nursing Homes • Factories Theaters Military facilities • Restaurants Auditoriums Places of Worship Office Buildings Retail Outlets Features Modular design for system flexibility and easy expansion Removable terminal blocks 50 watts of 25V audio power (expandable to 100 watts) RMS 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, or Wheelock pro- tocols Optional 70V transformer available for the primary amplifier. (Note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed) Eight Command Input Circuits to activate messages 1 to 8: - CMD1 and CMD2 are field selectable to be activated from 12 or 24 VDC Notification Appliance Circuits (reverse polarity) or contact closures - CMD3-CMD8 are activated by contact closures Speaker Circuits - Single Class B or Class A speaker Circuit - Two Class B or Class A speaker circuits (with optional NFC-BDA-25/70V Audio Amplifier installed) - Eight Class B or Class A speaker circuits (with optional NFC-BDA-25/70V and NFC-CE6 installed) NFC-50/100C can be controlled by an FACP via the ANN! ACS (EIA-485) link of the NFW2-100. Certified for seismic applications when used with the appro- priate seismic mounting kit Integral supervised microphone Microphone time-out feature which reverts back to prere- corded message if emergency page exceeds the pro- grammed time 14 recorded messages DN-60813:A2 • 7/28/2015 - Page 1 of 6 Field-selectable message and custom message recording capability using the local microphone, a USB port, or an external audio input External Audio Input can be used for background music Up to 60 second message duration for all messages Integral tone generators field selectable for multiple tone types Powered by integral AC power supply or batteries during AC fail Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss Piezo sounder for local trouble 100 event history log Three Form-C relays: — AC Power Loss Relay - TBI — System Trouble Relay - T132 — MNS Active - T133 500mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays System Status LEDs (refer to "Controls and Indicators" on product manual LSI000I-000NF-E) Integral Dress Panel Optional TR-CE-B semi-flush trim ring Any combination of up to eight (8) external remote con- soles: — Optional NFC-LOC Local operator console (includes cab- inet). See DN-60812. Optional Internal Expansion Modules NFC-CE6: Circuit Expander Module provides connections for up to six Class A or Class B speaker circuits. Circuits are con- figured through the web-based programming utility. NFC-BDA-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/I00C power output to 100 watts or can also be used as a backup amplifier. NFC-BDA-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100C power output to 100 watts or can also be used as a backup amplifier. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-50/1OOC primary amplifier to a 70V output. This transformer mounts directly to the NFC-50/100C main control board by two metal brackets. NFC-RTZNI: Remote Telephone Zone Module. Allows for secure access to the NFC via cell phone or remote telephone means; not ULC listed. Mi (P 55 EY$TESI' I ACME I IRESYSIEl II [QJ OVERRIDE SPEAKER IFIRIIIIIIIIII D3 SPEAKER M13 zc!E13 IN use ZONE 1 SPEAKER 14oZONE (IJ)? SPEAKER ZONE 11 M 2 SPEMER SPEAKER ZOSJE1S ONTOPASE IR ZONE SPEAKER ZONE 4 (IJE) SPEAKER ZONE 15 MICROPHONE ZPEMcSR ()t SPEAKER ZONE 17 (9 ZONES ZONES CoMSPEAKER SPEAKER ZONE1S (=} MESEAGE2 M ZONE 7 SPEAKER SPEAKER ( ZOPJE1S MESSAGES SPEAKER ZONE 0 SPEAKER ZONE 20 () MESSAGE4 ZONES SPEAKER () p SPEAKER ZONE 21 (=)k NENEAGEE SPE*ER ZONE 10 SPEAKER ZONE 22 () MESSAGE S S,ONEPEAKER (tii) SPEAKER ZONE 23 MESSAGE 7 SPEAKER ZONE 12 SPEAKER () I I TROWLESLEN I I CD 0130Ii.*PTI1t REMOTE AMPS 0 MAN CONSOLE > DIET. AMPI CR01110 SAUL! LOCI 1> 01ST. AMP 2 1> CN*POEH PUlL! I) ICC 2 DIST. AMP 3 L BATEERYFAULI RPU I > 0101 AMPS > DATAIJSFAIL! RPU2 > blOT AMPS 1> NACEAULT RPIJ3 oiso AMP & *susys RM1 DIST.AUPT 7 SYSTEMTROIIILS RM2 bISt5MP8 D AUDIO RISER IA&1 0 Control and Indicators PUSH BUTTON CONTROLS All Call • Message Select 1-14 MNS Control • Diagnostic Select System Control • Trouble Silence Speaker Select 1-24 • Console Lamp Test Page 2 of 6— Canadian DN-60813:A2 • 7/28/2015 CHG-75 charger 8116 0 CHG-120 charger rfl nifl rYfl nj - LLi NAC Circuit Speaker Circuits TB19 TB20&TB21 MEN iB iQ external battery charger-J7 0 NFC-BDA25/70V NFC-CE6 circuit expander optional amplifier Internal ___ options I I HrH .ØH1iI Irni Jh1 NFC-LOC e local operator console TB4 TB1 2 TB22 NFC-501100C FirstCommand (Possible Configurations) Canadian DN-60813:A2 • 7/28/2015 - Page 3 of 6 LED Status Indicators (visible with door closed) Fire System Active (green) LOC/RM 1-8 Active (green) MNS Control (green) Main Console Fault (yellow) System Control (green) AC Power (green) System in Use (green) Ground Fault (yellow) Speaker Zone 1-24 Active Charger Fault (yellow) (green) Speaker Zone 1-24 Fault Battery Fault (yellow) (yellow) OK to Page (green) Data Bus Fault (yellow) Microphone Trouble (yellow) NAC Fault (yellow) Message 1-8 Active (red) NAC Active (green) Message 1-8 Fault (yellow) System Trouble (yellow) Remote Amplifier 1-8 Fault (yellow) Audio Riser Fault (yellow) LOC/RM 1-8 Fault (yellow) LED Indicators (visible with door and dress panel open) Speaker Volume Control Fault (yellow). Option Card Fault (yellow). Amplifier Over Current Fault (yellow). Product Line Information (Primary Operating Console) 50 Watt, 25V sin- gle speaker zone emergency voice evacuation system, inte- gral microphone, built in tone generator and 14 recordable messages. NFC-CE6: Speaker Circuit/Zone Expander Module. NFC-BDA-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100C power output to 100 watts or can also be used as a backup amplifier. NFC-BDA-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/I00C power output to 100 watts or can also be used as a backup amplifier. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-501100C primary amplifier to a 70V output. This transformer mounts directly to the NFC-501100C main control board by two metal brackets. NFC-RTZM: Remote Telephone Zone Module. Allows for secure access to the NFC via cell phone or remote telephone means; not ULC listed. NFC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DN-60812 for more information. SElSKIT-COMMENC: Seismic kit for the NFC-50/I00C. Includes battery bracket for two 12 AH or 18 AH batteries. TR-CE-B: Optional Trim Ring. THUMBLTCH: Optional Thumb Latch. (Non ULC-Listed). CHG-75: 25 to 75 ampere-hours (AH) External Battery Charger. CHG-I20: 25-120 ampere-hours (AH) External Battery Charger. ECC-MICROPHONE: Replacement Microphone only. BAT-I270: Battery,12 volt,7.0AH (Two required). BAT-12120: Battery, 12 volt, 12.0 AH (Two required). BAT-12180: Battery,12 volt, 18.0 AH (Two required). BAT-12260: Battery, 12 volt, 26.0 AH (Two required). BB-26: Battery cabinet mounts up to two 26 AH batteries. Wiring Requirements See product manual, part number LS10001-001NF-E for detailed wiring requirements. Total System Capacity: (NFC-50/I00C only) Total Built-in Audio Power: 50 Watts. Total Expandable Audio Power: 100 Watts. Total Built-in Speaker Circuits: 2. Total Expandable Speaker Circuits: 8. Audio Message Max Time Duration: 60 seconds. External Audio Input: 1. Electrical Specifications PRIMARY (AC) POWER (TB 15) NFC-50/1OOC: 120 VAC, 60 Hz, 3.5 amps. ti7m size: minimum #14 AWG (200mm2) with 600 V insulation. SECONDARY POWER (BATTERY) CHARGING CIRCUIT (J7) Supports lead-acid batteries only. Float charge voltage at 27.3V Maximum charge current: 1.0 Amp Maximum battery charge capability: 2.8 Amps, 26AH (NFC cabinet holds max. 18AH battery). Minimum Battery size: 12 Amp Hour. AC Loss RELAY CONTACT RATING (TB3) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). FORM C - TROUBLE RELAY CONTACT RATING (TB2) 2.0 amps © 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive). MNS ACTIVE RELAY CONTACT RATING (TBI) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING (TB 19) One (1) Class B or Class A circuit. Power-limited circuitry, (Class 2) supervised. Nominal operating voltage: 24 VDC. Maximum signaling current for special application power: 2.OA. Maximum signaling current for regulated power: 200mA. Maximum wiring impedance: iQ. Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 K2, ½ watt, (P/N 71252) required for Class B operation. Refer to the Device Compatibility Document 15378 for listed compatible devices. NAC FOLLOWER OUTPUT REMOTE SYNC (TBI8) Connections for FACP NAC synchronization trigger signal. Trigger input voltage: 9 to 32 VDC, 24 VDC rated. Input current draw in Alarm condition: 10 mA at rated volt- age. Page 4 of 6 Canadian DN-60813:A2 -7/28/2015 SPECIAL APPLICATION POWER (Aux. POWER) (TBI7) 500mA@24VDC Used for powering addressable modules and associated End-of-Line power supervision relays Power-limited circuitiy. Refer to the Device Compatibility Doc- ument 15378 for a list of compatible devices. SPEAKER VOLUME CONTROL OVERRIDE (TB23) Class B or Class A circuit Special application power Power-limited circuitry, supervised Nominal operating voltage: 24 VDC Maximum signaling current: 0.25 amps Current limit: fuse-less, electronic, power-limited End-Of-Line Resistor: 4.7 KI, % watt, (P/N 71252) required for Class B operation Speaker Circuits Primary Speaker Circuit (TB20) Secondary Speaker Circuit (TB21) (with optional amplifier only) - Circuit can be wired Class B or Class A - Power-limited circuitry - Normal Operating Voltage: 25 VRMS @ 2 amps max and maximum Load Impedance of 12.5 (70V © 700 mA max. with maximum load Impedance of 10092 operation possible by plugging optional NFC-XRM-70V conversion transformer into J12 of the main control board) - Output Power: 50 watts (10 watts when background music is employed) - Frequency Range: 400Hz - 4,000Hz - Maximum total capacitance for each speaker circuit: 250 pF - End-of-Line Resistor required for Class B circuit: 15 M2, 1 watt (P/N: ELR-15K) Command Input Circuits (alarm polari- ties shown) CMD1 - TB4 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices down stream. CMD2 - TBS Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices downstream. CMD3 - TB6 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD4 - TB6 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD5 - TB7 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD6 - TB7 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD7 - T138 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD8 - TB8 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. Power-limited and supervised circuitry Normal Operating Voltage Range: 10.5 VDC - 29 VDC; (Maximum Voltage: 29 VDC) NAC Reverse Polarity Current (requires End-of-Line Resis- tor from NAC): 1.6 mA maximum Contact Closure Operation Current (requires 4.7K-Q, ½ watt End-of-Line Resistor PIN 27072): 6.6 mA maximum Maximum Wiring Impedance CMD1 - CMD8 (Contact Clo- sure Operation): 200f NOTE: When the system is programmed for Mass Notification, CMD1and CMD2 will be programmed for Reverse Polarity only. See manual P/N: LSI000I-00INF-E for more details. MAXIMUM INPUT IMPEDANCE: CMD1 & CMD2 (Reverse Polarity Operation): 20KI CMD1 - CMD8 (Contact Closure Operation): 4.751<0 NIGHT RING INPUT - T8I6, TERMINALS I (4) & 2 (-) Contact closure input Isolated, non-supervised Operation current: 3.8 mA, maximum Maximum wiring impedance: 30K Minimum isolation withstand voltage: 1500 VRMS EXTERNAL OPERATOR INTERFACE POWER OUTPUT (TB24) Non-resettable power for external operator interface com- ponents Power-limited circuitry, non-supervised Nominal operating voltage: 24 VDC Maximum output current: 0.80 amps Current limit: fuse-less, electronic, power-limited circuit EXTERNAL DATA BUS (EIA -485) (TBI2) Data connections for external operator interface components Redundant transceiver circuitry for Class A operability Power-limited circuitry, supervised Maximum wiring impedance: 13.2g. FACP DATA BUS (EIA-485) (TBI3) Dedicated connection to FACP serial bus Output terminals: pass-through to other system components. Isolated, supervised Minimum isolation withstand voltage: 1500 VRMS Maximum wiring impedance: 40iI (ANN-BUS), 261k (ACS-BUS) External Audio Riser (TB22) Class B or Class A audio connections to external operator interface components Power-limited circuitry, supervised Audio signal level: 3.85 V, maximum Frequency range: 400 Hz -4 KHz RMS Frequency range (NFC-50/125DA): 800Hz - 2KHz RMS EXTERNAL AUDIO INPUT (TB5) Input Impedance: 8.5Kg nominal @1KHz Input Voltage: 700 mVrms maximum Input Current: 0.1 mA maximum @ 700 mV NOTE: Some laptopslpersonal computers only provide an audio output for headphones. It may be necessary to adjust the head- phone output level for proper recording of voice messages. NFC-CE6 Circuit Expander Module Specifications Power-limited circuitry Up to six (6) circuits on the NFC-CE6 can be wired as Class B or Class A) Normal Operating Voltage for Speaker Circuits: 25 V@ 2.0 amps max. (Maximum Load Impedance of 12.511) Canadian DN-60813:A2 .7/28/2015—Page 5 of 6 70.0 V @ 700 mA max. with maximum Load Impedance of 1000 operation possible for the primary circuit by plugging in an optional NFC-XRM-70V conversion transformer into J12 of the main control board. The same operation is possi- ble for the optional 50W amplifier by selecting the NFC- BDA-70V model Speaker circuit wiring is supervised during standby, back- ground music, and alarm Output Power: 50 watts total; Frequency Range: 400Hz - 4,000Hz Maximum total capacitance: 250 pF. (Note that the total capacitance for the speaker outputs must not exceed the maximum of 250 pF) End-of-Line Resistor required for Class B speaker circuit: 15 K, I watt (PIN: ELR-15K) TBI3 on the main control board: ACS/ANN (ElA-485) electrically isolated link to FACP provides programmed speaker control Cabinet Specifications Backbox: 19.0(48.26 cm) high x 16.65(42.29 cm) wide x 5.20(13.23 cm) deep. Door: 19.26" (48.92 cm) high x 16.82(42.73 cm) wide x 0.12(0.30 cm) deep. Trim Ring (TR-CE-B): 22.00" (55.88 cm) high x 19.65" (49.91 cm) wide. Shipping Specifications Base Unit Weight: 27.85 lbs (12.63 kg). Temperature and Humidity ranges This system meets ULC requirements for operation at 0-49° Cl 32-120° F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27° C/60-80° F. Agency Listings and Approvals The listings and approvals below apply to the basic NFC-50/ 100 control panel. In some cases, certain modules may not be listed by certain approval agencies or listing may be in pro- cess. Consult factory for latest listing status. UUULC Listed S635 NYC Fire Dept. Certificate of Approval: #6163 Standards and Codes The NFC-50/100C complies with the following ULC Standar- dand International Building Codes. ° ULC: S635 IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). First Command® and Notifier® are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. a.. - This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. U16111111 A MMU(T1RIN9 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6— DN-60813:A2 •7/28/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6:0265 Page 1 of I CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NFC-50/100 and NFC-50/100E. These are 50-watt audio emergency voice evacuation panels expandable to 100-watt for fire applications, mass notification applications, or both. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: *ECC..LOC: Local Operator Console ECC-MCB; Main Control Board ECC-DKVCM; Display Board NFC-BDA-25V; Amplifier Module 25 VRMS NFC-BDA-70V; Amplifier Module 70 VRMS NFC-CE6; Speaker Circuit Expander Module NFC-XRM-70V; Transformer Module 70.7 VRMS RATING: Primary Operating: 120 V, 60 Hz, 3.5 A or 240 V, 50 Hz, 2 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instruction Manual for details. XLF: 6911-0075:0226 *12272016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division DN-6927:A2 FCPS-24S6(C/E) & FCPS. 24S8(CIE) 6- & 8-Amp 24-Volt Remote Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt tire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-2456/-2458 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-2458C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a 'sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently 'ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-2456) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. a AC trouble report selectable for immediate 2-hour delay. a Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated NAC power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). NOTIFIER® by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-2456C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-2456E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-2456: 4.0 A maximum. - FCPS-2458: 6.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-2456: 6.0 A maximum. - FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: supports lead-acid batteries only. DN-6927:A2 • 5/17/13 - Page 1 of 2 Float-charge voltage: 27.6 VDC. Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-2456) or 8.0 A (FCPS-2458). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-24S8 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FOPS is the originator of the strobe synchronization pulses on the FCPS's NAG outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAG expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-2458C) MEA: 299-02-E FM Approved Ordering Information 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULG-listed. FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. , This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Booms a All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6927:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL fl: FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM k VIM LISTING SERVICE LISTING No. Z020225 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 H PZI 11110 1.4 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division NP-200 Series Addressable Photoelectric Detectors General The NOTIFIER NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series Addressable Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detectors address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indi- cation. Dual electronic thermistors add 135°F (57°C) fixed tempera- ture thermal sensing on the NP-2001. The NP-200R is a remote test capable detector for use with DNR Series duct detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the Fire Warden panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA100Z. DN-60979:A NOTIFIER® by Honeywell NP-200 in B300-6 Base Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class B) wiring. NP-200R mounts in a DNR/DNRW duct detector housing. Operation Each NP-200 Series detector uses one possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire- Warden Series for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 200 hA © 24 VDC. Max current: 4.5 mA © 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. - B300-6: 6.1" (15.6 cm) diameter. - B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). Installation Operating temperature range: NP-200 series plug-in detectors use a detachable mounting base to • NP-200: 0°C to 50°C (32°F to 122°F); simplify installation, service and maintenance. • NP-200T: 0°C to 38°C (32°F to 100°F). NP-200R: installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). DN-60979:A • 3/29/18 - Page 1 of 3 Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the NP200 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listed: S911 —2:0028:050 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates FlashScanO and CLIP device. 6l White, Addressable photoelectric detector; B300-6 base included. FlashScan only. NP-200-IV: Ivory, Addressable photoelectric detector; B300-6 base included. NP-200T: White, Same as NP-200 but with thermal element; B300-6 base included. FlashScan only. NP-200T-IV: Ivory, Same as NP-200 but with thermal element; B300-6 base included. NP-200R: White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. FlashScan only. NP-200R-IV: Ivory, Remote test capable addressable photoelectric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IS: White, 6" base isolator. (CSFM: 7300-1653:0109 Pend- ing) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol.. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B2005-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. 8200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz .i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz -i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. B501-IV: Ivory color, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base. base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501 BP: Bulk pack of B501-WHITE contains 10. U.S. single-gang electrical box. For use with B501 (A) and B300- B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) 6(A). B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) M02-04-00: Test magnet. B224RBA-WH: White, relay base, ULC listing. M02-09-00: Test magnet with telescoping handle. B224RBA-IV: Ivory, relay base, ULC listing. B224Bl-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224Bl-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BlA-WH: White, isolator detector base, ULC listing. B224BlA-IV: Ivory isolator detector base, ULC listing. DN-60979:A • 3/29/18 — Page 2 of 3 NOTIFIER® and FIREWARDEN® are a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO oo We try to keep our product information up-to-date and accurate. 1 We cannot cover all specific applications or anticipate all requirements. ___________ All specifications are subject to change without notice. IFfflIfC&MNlW1UUf1 QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203)484-7118. www.notifier.com Page 3 of 3— DN-60979:A • 3/29/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-9511, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131, *B224RB (CSFM No. 7300-1653:0126); B2005, B200SR (CSFM No. 7300-1653:0213); B2005-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B21OLP B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW(CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 12/16/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM $ SENSOR Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Automatic selection of 12- or 24-volt operation at 15 and 30 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) Speakers offer high fidelity and high volume sound output 520 Hz capable with compatible FACP Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper-resistant construction Updated modern aesthetics Aaencv Listinas SIGNAUNG LISTED APPROVED S4048 FM approved except or ALERT models 3057493 System Sensor L.Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy Attach a universal mounting plate to a 4 x 4 x 21,8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, [-Series speaker strobes, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor [-Series model listed to U[1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync'Circuit model MD[3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 VDC/RNR 1,2 Operating Voltage Range (includes fire 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power 1/4, ½, 1, 2 watts - Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 520Hz capable with compatible FACP. UL Current Draw Data IuIU Max. Strobe 1I Draw IfiiY±I:Ii 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2W 82 82 1W 85 85 2W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2W 80 80 1W 83 83 2W 86 86 L-Series Dimensions 6.80 dia Ceiling Speaker 6.80 dia Ceiling Speaker Strobe Surface Mount! Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box L-Series Ordering Information White Red Description SPCWL SPCRL Speaker only SPSCRL t4aeW$troTd, SPSCWL-P - Plain, Speaker Strobe SPSCWL-SP - Fuego, Speaker Strobe SPSCWL-CLR-ALERT - Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring 5 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. for current product information, including the latest version of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensor.curn www.systemsensor.com AV0S86601 • 03117 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3Zbj63:QQ Page 1 of 2 CATEGORY: 7320-- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 464-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor Models: SPRL and SPWL Wall Speakers; SPCRL and SPCWL Ceiling Speakers; SPSRL, SPSWL, SPSRL-P, SPSRL-SP, SPSWL-P, SPSWL-ALERT and SPSWL-CLR-ALERT Wall Speaker Stobes; SPSCRL, SPSCWL, SPSCWL-P, SPSCWL-SP and SPSCWL-CLR-ALERT Ceiling Speaker Strobes. Wall Bezel Parts: BZSPR-P, BZSPR-AL, BZSPR-EV, BZSPR-AG, BZSPR-PG, BZSPR-F and BZSPR-SP, BZSPW-P, BZSPW-AL, BZSPW-EV, BZSPW-AG, BZSPW-PG, BZSPW-F and BZSPW-SP, Ceiling Bezel Parts: BZSPRC-P, BZSPRC-AL, BZSPRC-EV, BZSPRC-AG, BZSPRC-PG, BZSPRC-F and BZSPRC-SP, BZSPWC-P, BZSPWC-AL, BZSPWC-EV, BZSPWC-AG, BZSPWC-PG, BZSPWC-F and BZSPWC-SP, WallTrim Rings for Speaker Strobes: TR2 and TR2W CeilingTrim Rings for Speaker Strobes: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBSPRL and SBBSPWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-27-17 gt 8 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7320-1653:0505 Page 2 of 2 RATING: 25 or 70.7 VAC, 1/4,1/2,1, 2Watt outputs. Regulated 12 VDC and 24 VDC/FWR is for 2-wire strobe portion. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as speakers and speaker-strobes when used with separately listed compatible fire alarm control units. Suitable for indoor use, dry and damp environments. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division f~ SYSTEM $ SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Aaencv Listinas SIGNAUNG APPROVED 0 LISTED S5512 FM approved except S4011 for ALERT models 7135-16530503 3057383 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12to18AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSS6800 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (MA RMS), 2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3. 1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 31K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn IHorn 17 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 - AVDS86800 L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes SCRL Strobe, Red PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White 71 CWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sessor. Product specifications subject to change without notice. Visit systemoeosor.com SENSOR Phone: 800-SENSOR2 ' Fax: 630-377-6495 Or current product intorrnaoon, mclud,ng the tatest version of 111,s data sheet AVDS86801 • 03117 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listees data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr selling: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division NOTIFI ER® by Honeywell DNR(A) and DNRW Intelligent Photoelectric Duct Detectors The Notifier DNR(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectan- gular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5-20.32 m/s), temperatures of -4°F - 158°F (-20°C - 70°C), and a humidity range of 0-95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier DNR(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accesso- ries. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min —4,000 ft/mm (0.5 m/s —20.32 m/s) Versatile mounting options: square or rectangular configuration Broad ranges for operating temperature (-4°F - 158°F, -20°C - 70°C) and humidity (0% - 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Cover tamper signal Increased wiring space with a newly added 3/4" conduit knockout Available space within housing to accommodate mounting of a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection Remote testing capability Requires com line power only Accommodates an addressable relay module, sold separately, (FRM-1) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F - 158°F (-20°C - 70°C) Storage Temperature Range: -22°F - 158°F (-30°C - 70°C) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W) housings with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RAIOOZ OmA 12mA Max RTS151/RTSI51KEY OmA 12mA Max Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. UL: S635, S3705 • LIL S635 cSFM-3240-16530209 FM approved Product Line Information NOTE: "A suffix indicates ULC listed model. nj&R(A~)Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated. FSP-951 R(A)-IV: Remote test capable addressable low-profile pho- toelectric smoke detector; ivory; supports CLIP and FlashScan® protocols FSP-951R(A): Remote test capable addressable low-profile photo- electric smoke detector; white; supports FlashScan protocol only FSP-951 (A)-IV: Addressable low-profile photoelectric smoke detec- tor; ivory; supports CLIP and FlashScan protocols FSP-951 R(A): Addressable low-profile photoelectric smoke detec- tor; white; supports FlashScan protocol only Operating Humidity Range: 0% - 95% relative humidity (non-con- DCOIL: Remote test coil. Required for older DNR(W) duct detector densing) housing Air Duct Velocity: 100— 4,000 ft/mm (0.5-20.32 m/s) DUCTCOV: Retrofit DNR cover for manufactured prior to April 2014 DN-60429:C2 1117/2019—Page lof2 DUCTCOVW: Retrofit DNRW cover for manufactured prior to April 2014 DSTI (A): Metal sampling tube duct width up to 1 ft (0.3m) DSTI .5(A): Metal sampling tube duct widths up to 1 ft - 2 ft (0.3 - 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft —4 ft (0.6 - 1.2 M) DST5(A): Metal sampling tube duct widths up to 4 ft —8 ft (1.2— 2.4 M) DSTIO(A): Metal sampling tube duct widths up to 8 ft - 12 ft (2.4 - 3.7 m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RAIOOZ(A): Remote annunciator alarm LED RTSI 51(A): Remote test station RTSI 51 KEY(A): Remote test station with key lock Important Notes DNR(V') duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNR(W) duct detector housings with a date code of 0012 or ear- lier require a DCOIL and auxiliary 24 VDC power for remote test applications. iso 000i iuwrgii QUIIITY $YSHMS This document is not intended to be used for installation purposes. We try to keep our product information up.to.date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER 12 Clintonville Road Notifierth and FtashScanth are o registered trademark of Honeywell Inter- national Inc. Northford, CT 06472 52019 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. M4 T M WO 2 0 n Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division NC-100R(A) Relay Module for FireWarden Series Panels General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). 'Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-1 00-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-1 OOR(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. dn-60383:A2 ©NOTIFIER® by Honeywell NC-i OOR(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06/17/10 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S635. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information ntelIigentdrrmule. NC-i OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. MMMINMMMS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. wwwnotifier.com Page 2 of 2— dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NMM-IOOP, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 71