Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 101; FPC2018-0214; PermitPERJiET REPORT Csity of Carlsbad Print Date: 12/13/2021 Permit No: FPC2018-0214 Job Address: 2525 EL CAM INO REAL, U 101, CARLSBAD, CA 92008-1204 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 1563020900 Track U: Applied: 07/17/2018 Valuation: $388,773.46 Lot U: Issued: 08/13/2018 Occupancy Group: Project #: Finaled CIoe Out: 02/01/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: TEXAS DE BRAZIL -SPRINKLER TI (66 HEADS) Applicant: FPContractor: VFS FIRE & SECURITY SERVICES VFS FIRE AND SECURITY SERVICES SALVADOR JASSO 501 W SOUTHERN AVE 501 W SOUTHERN AVE ORANGE, CA 92865-3217 ORANGE, CA 92865-3217 (714) 778-6070 (714) 919-8351 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I ffC2-Di'S-02-(+ FIRE & SECURITY SERVICES VFS FIRE AND SECURITY 501 W. SOUTHERN AVE. ORANGE, CA 92865 714 778 6070 Job Name : TEXAS DE BRAZIL Building : SPACE 101 Location : 2525 EL CAMINO REAL CARLSBAD, CA System : SYS-1 AREA I Contract : 183167 Data File : VFS FIRE TdeB.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 4. VFS FIRE AND SECURITY Page TEiXAS DE BRAZIL Date 07/10/2018 HYDRAULIC CALCULATIONS for Project name: TEXAS DE BRAZIL Location: 2525 EL CAMINO REAL CARLSBAD, CA Drawing no: SPACE 101 Date: 07/10/18 Design Remote area number: SYS-1 AREA 1 Remote area location: TEXAS DE BRAZIL Occupancy classification: L.H / O.H1 Density: .15 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: SEE ATTACHED HEAD SPECS. No. of sprinklers calculated: In-rack demand: 0 - GPM Hose streams: 250 - GPM Total water required (including hose streams): 78.21 - GPM @ 890.99 - Psi Type of system: WET Volume of dry orpreaction system: -Gal Water supply information Date: 04-05-2017 Location: MARRON RD. WEST OF PLAZA DRIVE (WESTFIELD PLAZA) Source: HYDRANT NUMBER; H60994 Name of contractor: VFS Fire & Security Services Address: 501 W. Southern Ave. / Orange, CA 92865 I Phone number: (714)778-6090 Name of.designer: SAL JASSO Authority having jurisdiction: CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information orgridded systems here.) -10% FROM PRESSURES -10% WAS DEDUCTED FROM EXISTING STATIC AND RESIDUAL PRESSURES LIGH HAZARD AREAS IN BACK OF KITCHEN WHERE CALCULATED AT .15/1500 & 130SQFT MAX HOWEVER THIS AREA IS LIGH HAZARD. (WORST CASE BEING USED) Computer Programs by Hydratec Inc. Revision: 50.52.1 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: The Shoppes at Carlsbad SRU: (Assigned upon plan submittal) PROJECT ADDRESS: CITY: Carlsbad PHONE: ( 714 ) 778.6070 (yES Fire & Security Services) FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction TypE SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY, CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Marron Road west of Plaza Dr. (Westfield Plaza) TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 92 PSI Hydrant Number (if applicable):H60994 Elevation of test: 43 Feet Date/lime of Test:--------------------- ____________- .- °itot PSI Corresponding Flow GPM Total Flow: 6,050 GPM Residual Pressure 42 PSI Atpeakdemand, this water system is capable of providing afire flow discharge at 20 psi of 7,350 gpm. However, this exceeds the District's maximum velocity criteria of 15 fps. Therefore, the maximum allowable fire flow for this site is 6,050 gpm. 'Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: J ennifer R. Mael, P.E. Eng. Lic. No. (if applicable): C69606 Signature:__________________________________________ Title/Org: P '!_ctManager Date: 04/05/2017 Water Supply Curve C VFS FIRE AND SECURITY Page 2 TEXAS DE BRAZIL Date 07/10/2018 City Water Supply: Demand: Cl - Static Pressure : 82.8 Dl - Elevation : 6.930 C2 - Residual Pressure: 37.8 D2 - System Flow .640.99 C2 - Residual Flow : 6050 D2 - System Pressure : 78.212 Hose ( Demand) : 250 D3 - System Demand : 890.99 Safety Margin : 3.287 150 140 130 120 R° E10° 90 s 80 V U 70 R 60 50 --- 40 30 20 - a Dl .a.&L.4.a VVVI I I I 10 I I I I 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 VFS FIRE AND SECURITY Page 3 TEXAS DE BRAZIL Date 07/10/2018 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure CON 82.8 37.8 6050.0 81.499 890.99 78.212 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 12.0 5.6 12.13 19.5 1 12.0 5.21 13.99 19.5 K=K @ HD2 2 12.0 5.21 14.01 19.51 K=K @ HD2 3 12.0 5.21 14.07 19.56 K=K @ HD2 4 12.0 5.21 14.25 19.68 K=K @ HD2 5 12.0 5.21 14.92 20.14 K=K @ HD2 6 12.0 5.21 17.91 22.06 K=K @ HD2 7 12.0 5.21 16.49 21.17 K=K @ HD2 8 12.0 5.21 16.51 21.19 K=K @ HD2 9 12.0 5.21 16.58 21.23 K=K @ HD2 10 12.0 5.21 17.62 21.89 K=K@ HD2 11 12.0 20.01 12 12.0 5.21 20.7 23.72 K=K@ HD2 12A 12.0 21.04 14 12.0 5.21 20.93 23.85 K=K @ HD2 15 12.0 22.43 16 12.0 5.21 22.7 24.84 K=K @ HD2 16A 12.0 24.18 16B 12.0 5.21 24.58 25.85 K=K @ HD2 13 12.0 5.21 24.37 25.74 K=K @ HD2 17 12.0 5.21 25.38 26.27 K=K @ HD2 20 12.0 5.21 26.6 26.89 K=K @ HD2 21 12.0 5.21 26.63 26.9 K=K@ HD2 22 12.0 5.21 28.65 27.91 KK@ HD2 23 12.0 32.19 24 12.0 35.93 30 12.0 5.21 32.37 29.66 KK@ HD2 31 12.0 5.21 32.41 29.68 K=K @ HD2 32 12.0 5.21 32.64 29.79 K=K @ HD2 33 12.0 5.21 33.26 30.07 K=K @ HD2 40 12.0 5.21 24.64 25.88 K=K @ HD2 41 12.0 5.21 28.47 27.82 K=K @ HD2 42 12.0 5.21 33.53 30.19 K=K @HD2 43 12.0 42.06 44 12.0 57.56 45 12.0 58.37 34 12.0 36.62 25 12.0 37.89 18 12.0 38.17 45A 12.0 58.61 46 12.0 61.17 47 12.0 62.26 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 VF FIRE AND SECURITY Page 4 TEXAS DE BRAZIL Date 07/10/2018 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 48 12.0 63.7 113 12.0 64.24 TRS 4.0 68.41 BRS 2.0 69.49 UG -4.0 72.32 UG1 -4.0 72.79 UG2 -4.0 72.81 DC1 -4.0 72.83 DC2 -4.0 78.13 CON -4.0 78.21 250.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 EOD VFS FIRE AND SECURITY Page 5 TEXAS DE BRAZIL Date 07/10/2018 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 Etev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf HDI 1 2 5.60 19.50 1 T 5.0 6.000 120 12.125 to 2E 4.0 9.000 0.0 HD2 12 19.5 1.049 0.0 15.000 0.1242 1.863 Vel 7.24 0.0 HD2 19.50 13.988 KFactor= 5.21 1 12 . 5.21 19.50 1.5 0.0 1.500 120 13.988 K= K@ HD2 to 0.0 0.0 0.0 2 12 19.5 1.682 0.0 1.500 0.0127 0.019 Vet = 2.82 2 12 5.21 19.51 1.5 0.0 1.500 120 14.007 K= K@HD2 to 0.0 0.0 0.0 3 12 39.01 1.682 0.0 1.500 0.0447 0.067 Vel = 5.63 3 12 5.21 19.56 1.5 0.0 1.833 120 14.074 K= K@ HD2 to 0.0 0.0 0.0 4 12 58.57 1.682 0.0 1.833 0.0955 0.175 Vel = 8.46 4 12 5.21 19.68 1.5 0.0 3.333 120 14.249 K= K@ HD2 to 0.0 0.0 0.0 5 12 78.25 1.61 0.0 3.333 0.2013 0.671 Vel = 12.33 5 12 5.21 20.14 1.5 0.0 9.708 120 14.920 K= K@ HD2 to 0.0 0.0 0.0 6 12 98.39 1.61 0.0 9.708 0.3080 2.990 Vel = 15.51 6 12 5.21 22.07 1.5 0.0 7.000 120 17.910 K= K@ HD2 to 0.0 0.0 0.0 12A 12 120.46 1.61 0.0 7.000 0.4476 3.133 Vel = 18.98 0.0 12A 120.46 21.043 KFactor= 26.26 7 12 5.21 21.17 1.25 0.0 0.500 120 16.491 K= K@ HD2 to 0.0 0.0 0.0 8 12 21.17 1.38 0.0 0.500 0.0380 0.019 Vet = 4.54 8 12 5.21 21.19 1.25 0.0 0.500 120 16.510 K=K@HD2 to 0.0 0.0 0.0 9 12 42.36 1.38 0.0 0.500 0.1380 0.069 Vel = 9.09 9 12 5.21 21.23 1.25 0.0 3.583 120 16.579 K= K@ HD2 to 0.0 0.0 0.0 10 12 63.59 1.38 0.0 3.583 0.2908 1.042 Vet = 13.64 10 12 5.21 21.88 1.25 0.0 4.750 120 17.621 K= K@ HD2 to 0.0 0.0 0.0 11 12 85.47 1.38 0.0 4.750 0.5027 2.388 Vel = 18.33 11 12 0.0 1.5 0.0 2.917 120 20.009 to 0.0 0.0 0.0 12 12 85.47 1.61 0.0 2.917 0.2372 0.692 Vet = 13.47 12 12 5.21 23.73 1.5 0.0 0.917 120 20.701 K= K@ HD2 to 0.0 0.0 0.0 12A 12 109.2 1.61 0.0 0.917 0.3730 0.342 Vet = 17.21 12A 12 120.45 1.5 0.0 2.250 120 21.043 to 0.0 0.0 0.0 13 12 229.65 1.61 0.0 2.250 1.4773 3.324 Vet = 36.19 0.0 13 229.65 24.367 K Factor= 46.52 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Cal culations - Hazen-Williams VFS FIRE AND SECURITY Page 6 TEXAS DE BRAZIL Date 07/10/2018 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 14 12 5.21 23.85 1 0.0 8.333 120 20.927 K= K@ HD2 to 0.0 0.0 0.0 15 12 23.85 1.049 0.0 8.333 0.1802 1.502 Vel = 8.85 15 12 0.0 1 0.0 1.500 120 22.429 to 0.0 0.0 0.0 16 12 23.85 1.049 0.0 1.500 0.1800 0.270 Vel = 8.85 16 12 5.21 24.84 1.25 T 6.0 2.333 120 22.699 K= K@ HD2 to 0.0 6.000 0.0 16A 12 48.69 1.38 0.0 8.333 0.1775 1.479 Vel = 10.44 16A 12 -37.95 1.25 T 6.0 11.375 120 24.178. to 0.0 6.000 0.0 13 12 10.74 1.38 0.0 17.375 0.0109 0.189 Vel = 2.30 0.0 13 10.74 24.367 KFactor 2.18 16A 12 37.95 1.25 0.0 3.625 120 24.178 to 0.0 0.0 0.0 16B 12 37.95 1.38 0.0 3.625 0.1120 0.406 Vel= 8.14 16B 12 ' 5.21 25.85 1.25 E 3.0 10.292 120 24.584 K = K @ HD2 to 0.0 3.000 0.0 41 12 63.8 1.38 0.0 13.292 0.2927 3.891 Vel = 13.69 0.0 41 63.80 28.475 KFactor 11.96 13 12 5.21 266.13 2.5 0.0 5.750 120 24.367 K = K @ HD2 to ' 0.0 0.0 0.0 17 12 266.13 2.635 0.0 5.750 0.1762 1.013 Vel = 15.66 17 12 5.21 26.27 2.5 T 16.474 44.542 120 25.380 K = K @ HD2 to 0.0 16.474 0.0 18 12 292.4 2.635 ' 0.0 61.016 0.2096 12.792 Vel = 17.20 0.0 18 292.40 38.172 KFactor= 47.33 20 12 5.21 26.89 1.25 0.0 0.500 120 26.597 K = K @ HD2 to . 0.0 0.0 0.0 21 12 26.89 1.38 0.0 0.500 0.0600 0.030 Vel = 5.77 21 12 5.21 26.90 1.25 0.0 9.458 120 26.627 K= K@ HD2 to . 0.0 0.0 0.0 22 12 53.79 1.38 0.0 9.458 0.2135 2.019 Vel = 11.54 22 12 5.21 27.91 1.25 2E 6.0 1.667 120 28.646 K= K@ HD2 to 0.0 6.000 0.0 23 12 81.7 1.38 0.0 7.667 0.4624 3.545 Vel = 17.52 23 12 0.0 1.25 0.0 8.083 120 32.191 to 0.0 0.0 . 0.0 24 12 81.7 1.38 0.0 8.083 0.4625 3.738 Vel = 17.52 24 12 0.0 2 T 10.0 20.375 120 35.929 to 0.0 10.000 0.0 25 12 81.7 2.067 0.0 30.375 0.0646 1,963 Vel = 7.81 0.0 25 81.70 37.892 KFactor= 13.27 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 7 TEXAS DE BRAZIL Date .07/10/2018 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Etev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 30 12 5.21 29.66 2 0.0 5.000 120 32.366 K= K@ HD2 to 0.0 0.0 0.0 31 12 29.66 2.157 0.0 5.000 0.0080 0.040 Vel = 2.60 31 12 5.21 29.68 2 0.0 8.000 120 32.406 . K = K @ HD2 to 0.0 0.0 0.0 32 12 59.34 2.157 0.0 8.000 0.0291 0.233 Vet = 5.21 32 12 5.21 29.79 2 0.0 10.000 120 32.639 K = K @ HD2 to 0.0 0.0 0.0 33 12 89.13 2.157 0.0 10.000 0.0617 0.617 Vel = 7.83 33 12 5.21 30.07 2 T 12.307 19.500 120 33.256 K= K@ HD2 to 0.0 12.307 0.0 34 12 119.2 2.157 . 0.0 31.807 0.1057 3.361 Vet = 10.47 0.0 34 119.20 . 36.617 K Factor = 19.70 40 12 5.21 25.88 1 E 2.0 11.292 120 24.640 K=K@HD2 to T 5.0 7.000 0.0 41 12 25.88 1.049 0.0 18.292 0.2097 3.835 Vel = 9.61 41 12 5.21 91.63 1.25 0.0 5.583 120 28.475 K= K@ HD2 to 0.0 0.0 0.0 42 12 117.51 1.38 0.0 5.583 0.9058 5.057 VeI= 25.21 42 12 5.21 30.19 1.25 0.0 6.167 120 33.532 K= K@ HD2 to . 0.0 0.0 0.0 43 12 147.7 1.38 0.0 6.167 1.3828 8.528 Vet = 31.68 43 12 0.0 1*5 0.0 23.750 120 42.060 to 0.0 0.0 0.0 44 12 147.7 1.61 0.0 23.750 0.6528 15.504 Vet = 23.28 44 12 0.0 2 0.0 4.167 120 57.564 to 0.0 0.0 0.0 45 12 147.7 2.067 0.0 4.167 0.1932 0.805 Vet = 14.12 45 12 0.0 4 E 10.0 1.750 120 58.369 to T 20.0 30.000 0.0 45A 12 147.7 4.026 0.0 31.750 0.0075 0.239 Vet = 3.72 0.0 45A 147.70 58.608 K Factor = 19.29 34 12 119.20 2.5 3E 24.711 7.292 120 36.617 to . 0.0 . 24.711 0.0 25 12 119.2 2.635 0.0 32.003 0.0398 1.275 Vet = 7.01 25 12 81.70 2.5 0.0 2.667 120 37.892 to 0.0 0.0 0.0 18 12 200.9 2.635 0.0 2.667 0.1050 0.280 Vet = 11.82 18 12 292.39 2.5 E 8.237 12.333 120 38.172 to T 16.474 24.711 0.0 45A 12 493.29 2.635 0.0 37.044 0.5517 20.436 Vet = 29.02 45A 12 147.70 4 T 20.0 2.542 120 58.608 to 0.0 20.000 0.0 46 12 640.99 4.026 0.0 22.542 0.1137 2.562 Vel = 16.15 46 12 0.0 5 0.0 28.917 120 61.170 to 0.0 0.0 0.0 47 12 640.99 5.047 0.0 28.917 0.0378 1.093 Vet = 10.28 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 8 TEXAS DE BRAZIL Date 07/10/2018 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total PfIFt Pf 47 12 0.0 6 T 30.0 34.833 120 62.263 to 2E 28.0 58.000 0.0 48 12 640.99 6.065 0.0 92.833 0.0155 1.435 Vel = 7.12 48 12 0.0 6 E 17.603 26.333 120 63.698 to 0.0 17.603 0.0 113 12 640.99 6.357 0.0 43.936 0.0123 0.540 Vel = 6.48 113 12 0.0 8 3E 63.423 108.583 120 64.238 to 3F 31.712 95.135 3.465 TRS 4 640.99 8.249 0.0 203.718 0.0035 0.703 Vel = 3.85 TRS 4 0.0 8 G 4.0 5.000 120 68.406 to S 45.0 49.000 0.866 BRS 2 640.99 7.981 0.0 54.000 0.0041 0.220 Vel = 4.11 BRS 2 0.0 8 E 21.405 5.000 120 69.492 to T 41.62 63.025 2.599 UG -4 640.99 8.27 0.0 68.025 0.0034 0.231 Vel = 3.83 UG -4 0.0 8 0.0 114.708 120 72.322 to 0.0 0.0 0.0 UG1 -4 640.99 7.98 0.0 114.708 0.0041 0.466 Vel = 4.11 UG1 -4 0.0 8 0.0 10.000 140 72.788 to 0.0 0.0 0.0 UG2 -4 640.99 8.27 0.0 10.000 0.0026 0.026 Vel = 3.83 UG2 -4 0.0 8 0.0 5.000 150 72.814 to 0.0 0.0 0.0 DC1 -4 640.99 7.98 0.0 5.000 0.0026 0.013 Vel = 4.11 DC1 -4 0.0 8 5E 142.34 6.000 140 72.827 to 0.0 113.872 5.000 *Fixed Loss =5 DC2 -4 640.99 8.27 0.0 119.872 0.0026 0.308 Vel = 3.83 DC2 -4 0.0 10 T 67.474 10.000 150 78.135 to 0.0 67.474 0.0 CON -4 640.99 9.79 0.0 77.474 0.0010 0.077 Vel = 2.73 250.00 Qa = 250.00 CON 890.99 78.212 K Factor = 100.75 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary VFS FIRE AND SECURITY Page 9 TEXAS DE BRAZIL Date 07/10/2018 Fitting Legend Abbrev. Name % % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram VFS FIRE AND SECURITY Page 10 TEXAS DE BRAZIL Date 07/10/2018 19.5 HDI<- HD2 19.5 58.6 98.4 1 <-2 <-3 <-4 <-5 <-6 <-12A 39 78.3 120.5 21.2 63.6 85.5 229.7 7 <- 8 <- 9 <-- 10 <- 11 <-- 12 <- 12A<._ 13 42.4 85.5 109.2 23.9 48.7 14 <- 15 <- 16 <-- 16A<- 13 23.9 10.7 38 16A<- 16B<_ 41 - 63.8 I 10.7 I 266.1 13 <-- 17 <- 18 292.4 26.9 81.7 81.7 20 <-. 21 <-- 22 <- 23 <- 24 <- 25 53.8 81.7 29.7 89.1 30 <- 31 <- 32 <-_ 33 <- 34 59.3 119.2 25.9 147.7 147.7 40 <- 41 <- 42 <- 43 <-- 44 <_ 45 <-- 45A 117.5 147.7 147.7 119.2 493.3 641 641 641 641 641 641 34 <-25 <-18 <-45A<-46 <-47 <-48 <-113<- TRS<-BRS<- UG<- UGI<- UG2<- DCI<- DC2<- CON 200.9 641 641 641 641 641 641 Computer Programs by Hydratec Inc. Revision: 50.52.1 . .... I QUICK RESPONSE SERIES GL-QR SERIES GL-QRJCNV UPRIGHT CONVENTIONAL QUICK RESPONSE SERIES GL-QR SERIES GL-QRJSW PENDENT VERTICAL SIDEWALL Coca MD FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT -PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response Series GL-QR Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the ap- plicable standards. It offers the additional feature of greatly in- creased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used ad- visedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL-QR sprinkler proven ac- tuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the inter- nal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. 1. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (790C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) QUICK RESPONSE Factory tested hydrostatically to 500 psi (34 Bars) HORIZONTAL LPCB/CE Maximum low temperature glass bulb rating is -67°F (-55°C) SIDEWALL HORIZONTAL Frame - bronze • Deflector - brass Screw - brass SERIES GL-QRISW SIDEWALL Lodgement Wire - stainless steel • Bulb seat - copper SERIES GL-QRISW Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING s CLASSIFICATION AVAILABLE SPRINKLER co BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY I 135 F/155F 57t68 (J ORANGE/RED 100 38C INTERMEDIATE 175F/200F 79'C/93C YELLOW/GREEN 1501 86'C HIGH 286F 141C BLUE 2251 107C MAR 2018 GFS-lUoa (Formerly A-20) QUICK RESPONSE A UTOMA TIC SPRINKLERS UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome - White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16". 2FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. LISTINGS/APPROVALS TEMPERATURE NYC-DOB STYLE SIN K FACTOR HAZARD' cULus FM LPCB2 CE MEA ____ 135°F 155°F 175°F 200°F 286°F, (57°C) (68°C) (79°C) (93°C) (141°C) - 101-92-E GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115* 8.0* (W NPT) LH/OH X X X X X X -- --- --- X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X --- --- --- X GL4201 4.2 LH X X X X X X --- --- --- x PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101* 8.0* (W' NPT) LH/OH X X X X X X --- --- --- X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X --- -- GL2826 2.8 LH X X X X X X --- --- --- x GL4226 4.2 LH X X X X X X -- --- --- X HORIZONTAL GL5626 5.6 LH/OH X X X X X X X X SIDEWALL GL5627a 5.6 LH/OH X X X X X --- -- X X GL8127 8.0 LH/OH X X X X X X --- CONVENTIONAL GL5624 5.6 LH/OH (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- -- --- X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. PINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1I2 NPT, FOR RETROFIT ONLY 2 LPCB REF. NO. 147c105 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • SIN Style q Orifice products found to be defective in material or workmanship for a Thread Size . Temperature • Finishes desired period of one year from date of shipment. Quantity - Wrenches - PIN 325390 (1/2"); For specific. details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 GM6MM 1-800-248-0278 www.gIobesprinkler.com FIRE SPRINKLER CORPORATION MAR 2018 PRINTED U.S.A. GFS-100a (Formerly A-20) rj r I C1101C CflOIMP1I CJ tf%V3flAVATItkM "THE INCH" QUICK RESPONSE AUTOMATIC SPRINKLER GL5606 I JV I LUVUIIJ% WI UU4 I IUI ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DEscRIPTIoN AND OPERATION The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operations approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. This sprinkler offers the additional feature of greatly in- creased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2 3/4" diameter ceiling plate color finished to match the specifier's exact requirements. The Series GL-QR Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's GL5606 Concealed Sprinkler utilizes a 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA I See reverse side for Approvals and Specifications Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 35/16" diameter plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 'fl 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper 2 3/4" diameter plate Spring - nickel alloy• Seal - teflon Drop Pin - stainless steel SERIES GL-QR/INCH Bulb - glass with alcohol based solution, 3mm size WHITE FLAT PLATE Cover Plate - brass• Upper Escutcheon Assembly - steel CONCEALED PENDENT NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 35 Ff155 F 57'C/WC ORANGE/RED 100 F C INTERMEDIATE 75F/200F 79CJ93C YELLOW/GREEN 150F 66C MAR 2018 GFS-1 50a (Formerly A-38) "THE INCH" QUICK RESPONSE A U TOMA TIC SPRINKLER ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT GL5606 SPECIFICATIONS NOMINAL THREAD SIZE LENGTH FLAT COVER "K" FACTOR PLATE FINISHES* 5.6 1/2"NPT 2 1/2" Chrome (80 metric) (15mm) (6.4cm) White Painted Other Finishes12 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. ,FOR PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. ***FACTORY PAINTED COVER PLATES MUST NOT BE REPAINTED. NON-FACTORY APPLIED PAINT MAY ADVERSELY DELAY OR PREVENT SPRINKLER OPERATION IN THE EVENT OF A FIRE. APPROVALS STYLE SIN HAZARD' 135°F (57°C) Flat Cover Plate 155°F (68°C) Flat Cover Plate cULus *FM NYC-DOB MEA **1350F (57°C) 155°F (68°C) **155F (68°C) 175°F (79°C) 200°F (93°C) Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler 10192E Adjustable Concealed GL5606 LH/OH X X X X X X X X Pendent 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS OH: ORDINARY HAZARD LIGHT HAZARD CROSS SECTIONS 2 1/4 DIA. MIN. -j rIDLE 2/4"DIA.MIN. HOLE INCEUNG IN CEILING -17/8 OIA.-1 ----17/8" DIA.- lx 1/2'-..1 F? I 1 lx 2 3/46 MAX. 2 3/4 DROP PIN MAX. 1 7/8" MIN. 1 7/8" MIN, DEFLECTOR SUPPORT DEFLECTOR I DROP PIN SHELL " - \ 2 3/4"DIA. 1/8" I 3 5/16 OLA. FLAT COVER PLATE FLAT COVER PLATE 1" ADJUSTMENT FLAT PLATE CONCEALED PENDENT FLAT COVER PLATE SIZES WHITE 135°F (57°C) PART# WHITE 155°F (68°C) PART# CHROME.135°F (57°C) PART# CHROME 155°F (68°C) PART# 2 3/4" DIA. 332726 332731 332724 332729 35/16"DIA. 332706 - 332711 332704 332709 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity ° SIN ° Style Orifice products found to be defective in material or workmanship for a Thread Size Temperature. Finishes desired period of one year from date of shipment. ° Quantity - Wrenches - P/N 332765 For specific details of our warranty please refer to Price List Quantity - Protective Caps - P/N 332695 Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 016Lcom 0 . 989-846-4583 FAX 989-846-9231 ISPRINKLERCOPPORAUON 1-800-248-0278 www.globesprinkIer.com FIR MAR 2018 PRINTED U.S.A. GFS-150a (Formerly A-38) FIRE SPRINKLER CORPORATION STANDARD RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response Series CL-SR Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ./ ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- j L ance, it can be installed wherever standard spray sprinklers are ' specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response STANDARD RESPONSE Sprinklers should be used advisedly and under the direction of SERIES GL-SR SRlESGLSRJCNV approving authorities having jurisdiction. UPRIGHT CONVENTIONAL The heart of Globe's Series GL-SR sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that . contains a precisely measured amount of fluid. When heat is '7 absorbed, the liquid within the bulb expands increasing the f) internal pressure. At the prescribed temperature the internal Li pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is 1 -z distributed in an approved pattern depending upon the deflector . '. style used. . STANDARD RESPONSE The sprinkler and escutcheon are not factory assembled. SERIES GL-SR SERIES CL-SR/SW Assembly is done in the field. PENDENT VERTICAL TECHNICAL DATA SIDEWALL See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), - 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C) " 500'F (260°C) Available Upon Request Without Approvals Water Working Pressure Rating -175 psi (12 Bars) ' Factory tested hydrostatically to 500 psi (34 Bars) STANDARD RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C) SERIES CL-SR/SW SERIES GL-SR/SW Frame - bronze • Deflector - brass • Screw - brass LPCB/CE HORIZONTAL Lodgement Wire - stainless steel • Bulb seat - copper HORIZONTAL SIDEWALL Spring - nickel alloy• Seal - teflon SIDEWALL Bulb - glass with glycerin solution, 5mm size Escutcheon Assembly - steel .cPPINKI FR TFMPFRATIIRF RATIN(/(N A.c.cIFI(ATInN anri COLOR CODINC CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY — 135F/155 5710681 ORANGE/RED 10O'F 38C INTERMEDIATE 115F2QO 79093C YELLOW/GREEN 150E 66C HIGH 266'F 141'C BLUE 225'F 107'C EXTRA HIGH 360F 187C MAUVE 300'F 149C ULTRA HIGH 50OF 260C BLACK 475'F- 24,6C MAR 2018 GFS-100b (Formerly A-65) STANDARD RESPONSE AU TOMA TIC SPRINKLERS SERIES GL-SR UPRIGHT PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (1 5mm) 21/4" (5.7cm) Factory Bronze 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2"NPT(15mm) 2 1/4" (5.7cm) White Polyester3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) Wax Coated23'4 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL IS 9/16", 'WAX COATING cULus LISTED UP TO 200°F (93°C) ONLY, 'FINISHES AVAILABLE ON SPECIAL ORDER. LISTINGS/APPROVALS TEMPERATURE STYLE SIN FACTOR HAZARD' cULus FM LPCB2 CE MEAIOI.92.E 135°F 155°F 175°F 200°F "°286°F "360°F (57°C) (68°C) (79°C) (93°C) (141°C) (182°C) GL2861 2.8 LH X X X X X X X --- --- X GL4261 4.2 LH X X X X X X X --- --- --- X UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X GL8161° 8.0° (W NPT) ALL X X X X X X X --- --- --- X GL8164 8.0 ALL X X X X X X X X X X X GL2851 2.8 LH X X X X X X X --- --- --- X GL4251 4.2 LH X X X X X X X --- --- X PENDENT GL5651 5.6 ALL X X X X X X X X X X X GL8151° 8.0"(WNPT) ALL X X X X X X X --- --- --- x GL8156 8.0 ALL X X X X X X X X' X X X VERTICAL GL5675 5.6 LH X X X X X X X X SIDEWALLt GL8176 8.0 LH X X X X X X X GL2870 2.8 LH X X X X X X X - --- --- X GL4270 4.2 LH X X X X X X X --- --- --- X HORIZONTAL GL5670 5.6 LH/OH X X X X X X X X --- --- X SIDEWALL GL56710 5.6 ' LH/OH X X X X X X --- --- X X GL8171 8.0 LH/OH X X X X X X X --- CONVENTIONAL GL5668 5.6 LH/OH X X X X X X --- --- X X (OLD STYLE) G_ 8169 8.0 LH/OH X X X X X X --- --- --- X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPAI 3 AND ANY OTHER RELATED DOCUMENTS. 'BRASS FINISH ONLY WHEN RECESSED §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. ""NO FM APPROVALS FOR RECESSED SINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. "NO FM APPROVALS tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. OH: ORDINARY HAZARD tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. LH: LIGHT HAZARD 500"F (260°C) AVAILABLE UPON REQUEST WITH NO APPROVALS. ALL: ALL HAZARDS °1/2"NPT; RETRO-FIT ONLY 'LPCB REF. NO. 147c104 ORDERING INFORMATION SPECIFY Quantity" SIN" Style' Orifice ° Thread Size "Temperature. Finish desired Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"); P/N 312366/325401 (L.0.) "Quantity Protective Caps - P/N 327109-CAP (Friction Fit Recessed) Wnbm—, FIRE SPRINKLER CORPORATION MAR 2018 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. GFS-100b (Formerly A-65)