Loading...
HomeMy WebLinkAbout1824 MARRON RD; ; FPC2017-0321; Permit(ity of Carlsbad 1. Print Date: 12/14/2021 Permit No: FPC2017-0321 Job Address: 1824 MARRON RD, CARI.SBAD, CA 92008-1183 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: Track U: Applied: 11/02/2017 Valuation: $0.00 Lot U: Issued: 01/11/2018 Occupancy Group: Project U: Finaled Close Out: 12/09/2020 Uof Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: TUESDAY MORNING -SPRINKLER MONITORING -REPLACE SUPERVISORY SPRINKLER PANEL FPContractor: ALL COUNTY FIRE PROTECTION INC 10965 SAN DIEGO MISSION RD SAN DIEGO, CA 92108-2431-SAN DIEGO (619) 284-4770 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov ISPACEAGE ELECTRONICS, INC Specifications: The tire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall — - standard business type cards for key contact personn FPC20I7-0321 1824 Marron RD TUESDAY MORNING - SPRINKLER MONITORING - REPLACE SUPERVISORY SPRINKLER PANEL 1/10/2018 FPC20I 7-0321 Property Inton.nation Crrttttc,tlono end Appoovale 16.1 Systeni Inslatloflun Contractor, 16.5 Arnoriry Hoct,r5 Jutisdiion: 0O 0o.r. .0. e. soon 60.0 0.0 0.5.0.000.., nl_..................................... Equipment Infoernatlon o 1. . cr00. 04. 000.00.0., .0 50 50.00100 cr04 neon.5 non note, Ont-son-Ono .00.0.,.-. Lllnf4oSr. Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00672 Fire Document Box RED SSU00673 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doe # ED0479 for legal disclaimer ED0447 L110505 Rev.B 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! FIRE DOCUMENT BOX Standard Features: 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard Wcat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2010 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. ,W lip NFPA Made In U.S.A. Isogool f REGISTERED COMPANY . ADA Space Age Electronics, Inc. Www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508485.4740 Fax Space Age Electronics, Inc. 2013 E00447 L110505 Rev.13 1/2 No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION t ____ OFFICE OF THE STATE FIRE MARSHAL o FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell tnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.Kireyevhoneywell.com DESIGN: Models 2W-B, 2Wr-B, 4W-B and 4W7-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2W1-B and 4wr-B employ a thermistor type heat sensor (135F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5- 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LV001 *TG7LVA01 *TG7LVF0I and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *0407_2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-1653:0118 Page 1 of 1 CATEGORY: 7770 - VALVES/SWiTCHES LISTEE:' System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models PIBV2 and OSY2 valve supervisory switches. Suitable for outdoor use. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as valve supervisory switches for use in fire sprinkler systems. Suitable for outdoor use. NOTE: Formerly 7770-1209:149 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OP FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-1653:0145 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Klreyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models WFD20EXP, -25EXP, -30EXP, -30-2EXP, -35EXP, -40EXP, -50EXP, -60EXP, and -80EXP paddle-type wet pipe sprinkler, waterflow indicators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Model Size Working Pressure WFD20EXP 2' 450 psig WFD25EXP 2-1/2" 450 psig WFD30EXP 3" 450 psig WFD35EXP 3-1/2' 450 psig WFD40 EXP 4" 450 psig WFD50EXP 5" 450 psig WFD60 EXP 6" 450 psig WFD80 EXP 8" 450 psig WFD30-2EXP 3" 450 psig INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as waterflow indicators for use with wet pipe fire sprinkler systems. Suitable for use in Class I, Group B, C and D; Class II, Group E, F and G hazardous locations. NOTE: Formerly 7770-1209:202 06-20-05 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not X , an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0531:0113 Page 1 of I CATEGORY: 7770 - VALVES/SWITCHES LISTEE: V1CTAUL1C4901 Kesslersville Rd., Easton, PA 18040 Contact: Michael Erie (610) 823-3739 Fax (610) 923-3115 Email: merle@victauiic.com DESIGN: *Models 705 grooved-end type butterfly valves in sizes 2, 2-112", 3", 4", 5", 6", 8", 10' and 12". *Models 707C grooved-end type butterfly valves in sizes 2, 2-1/2", 3", 4", 5", 6", 8", 10" and 12". *Models 765 grooved-end type butterfly valves in sizes 2, 2-1/2", 3", 4", 5", 6", 8", 10" and 12". *Models 766 grooved-end type butterfly valves in sizes 2, 2-1/2", 3", 4", 5", 6", 8", 10" and 12" For above ground and indoor/outdoor use only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: *Models 705: 300 psi *Models 707C; 300 psi *Models 765: 365 psi *Models 766: 365 psi INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, UL label. APPROVAL: Listed as above ground water control butterfly valves for fire protection service. *Rev 0126 11 bh This listing is based upon technical data submitted by the. applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0174 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models UDACTF, 411, 411-UD and 411 UDAC digital alarm communicator transmitter and Model ABS-BRF enclosure (for use with Model UDACTF only). The UDACTF, 411, 411 LID and 411 UDAC units are intended to provide central station service over a standard two-wired telephone switching network. The UDACTF is for use with listee's separately listed fire alarm control units. The 411,4I1UDAC and 411-UD are for use with any UL and CSFM listed control units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: UDACTF: 21.2-28.2 VDC 411, 411-UD: 11.7- 12.4 VDC (nominal) or 21.3-24.0 VDC (nominal) 411UDAC: 120 VAC, 12 VDC; INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as digital alarm communicator transmitters for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ONTROL TAMPER, ZONE 2 ZONE 3 ATER FLOW SWITCH, ZONE 1 ACP SMOKE, ZONE 4 I ALL COUNTY FIRE I 3163 ADAMS AVE SAN DIEGOICA 9211 I wGoum PLM I 1$ oJny — 71F1